Water Resources Department-WRD has published Installation Of Darikini Solar Mini Rli Under Sarenga Block Under Bankura-Ii Sub Division Under Bankura ( Am ) Division Under Jap Programme 2020-21. Submission Date for this Tender is 13-02-2021. Lift Irrigation Tenders in Bankura West Bengal. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 10-Feb-2021 | BID SUBMISSION CLOSING DATE HAS BEEN EXTENDED | Date | 13-02-2021 |
Name of Work:- Installation of DARIKINI Solar Mini RLI under Sarenga Block Under Bankura-II Sub Division under Bankura(AM) Division Under JAP Programme 2020-21 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | DBMS:-Conduct of an awarness meeting among villagers for collection of mouza map including spout wise list of benificiary with plot number & quatity of irrigated area for each farmer for sustainability of the irigation structure in future.the expenses of the programme head as follows .meeting arangement,tea,and biscuits,travelling expens,service charge etc. | BI01010001010000000000000515BI0100001113 | 1 | Each Side |
2 | 2 | Preparation the documents of the association of list of benificiary with benifitted area agaist each spout . The expences of the programme head as follows typing,printing,Preapration of the set documents service charge etc | BI01010001010000000000000515BI0100001114 | 1 | Each Side |
3 | 3 | Field visit for for cross check up of spout wise benificiary list including their area to be irrigated. The expences of the programme head as follows.Travelling expences,service charge etc. | BI01010001010000000000000515BI0100001115 | 1 | Each Side |
4 | 4 | Collection of data like plot number, latitude & lognitude of P.H., D.C., & each spout & Preparation of documents & submission of same to the office in duplicate.The expences of the programme head as follows.Collecting,typing,Printing,Preparation of the set documents,service charge etc. | BI01010001010000000000000515BI0100001116 | 1 | Each Side |
5 | 5 | Collection of phatography like prework, ongoing & post work covering lay-out,pipe trenches,trenches with pipe before earth filling, measurment ,final work with name plate, & submission of same to the office in duplicate.The expences of the programme head as follows.Collecting,typing,Printing,Preparation of the set documents,service charge etc. | BI01010001010000000000000515BI0100001117 | 1 | Each Side |
6 | 6 | Submission of soft copy( by a DVD) of all above data like spout wise benificiary list including area of irrigated land of each farmer, phtography, latlong of P.H., D.C.,& each spout chamber in duplicate. the programme head as follows Preparation of the set documents,service charge etc. | BI01010001010000000000000515BI0100001118 | 1 | Each Side |
7 | 7 | WUA:-Conduct of an awarness meeting among villagers for mobilazation of community towards formation of a committee for sustainability of the irigation structure in future.the expenses of the programme head as follows .meeting arangement,tea,and biscuits,travelling expens,service charge etc. | BI01010001010000000000000515BI0100001119 | 1 | Each Side |
8 | 8 | preparation the documents of the association of water users for WUA registration Act 1961 . The expences of the programme head as follows typing,printing,Preapration of the set documents service charge etc | BI01010001010000000000000515BI0100001120 | 1 | Each Side |
9 | 9 | field visit for signature of the registration paper of the WUA members. The expences of the programme head as follows.Travelling expences,service charge etc. | BI01010001010000000000000515BI0100001121 | 1 | Each Side |
10 | 10 | Preparation of the whole registration documents with authorization paper by WUA and department.The expences of the programme head as follows.typing,Printing,Preparation of the set documents,service charge etc. | BI01010001010000000000000515BI0100001122 | 1 | Each Side |
11 | 11 | Submission of the registration documents of WUAat kolkta for getting registration certificate under society registration act 1961.The expences of of the programme head follows travelling expences, food and lodging expences to kolkata and return ,service charge etc. | BI01010001010000000000000515BI0100001123 | 1 | Each Side |
12 | 12 | Participation in hearing for WUA registration confirmation at society registration office.the expences of the programme head as follows. Travelling expences, food and lodging expences to kolkata and return ,service charge etc. | BI01010001010000000000000515BI0100001124 | 1 | Each Side |
13 | 13 | collection of WUA certificate. The expences of the programme Head as follows Travelling expences, food and lodging expences to kolkata and return ,service charge etc. | BI01010001010000000000000515BI0100001125 | 1 | Each Side |
14 | 14 | MATERIAL :-Supply & transportation 200 mm OD, Class - l Rigid PVC Pipes conforming to IS:4985 / 2000 ( with latest ammendments) and duly ISI marked with 1 (one no. loose coupler conforming to IS:10124 part-V ) 1988 duly ISI marked for every 6 m. Length, required Solvent Cement for each pipe as per IS: 14128/1994 ( with latest ammendments ) up to the destination point inclusive of all charges. [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001126 | 300 | m |
15 | 15 | Supply & transportation 140 mm OD, Class - l Rigid PVC Pipes conforming to IS:4985 / 2000 ( with latest ammendments) and duly ISI marked with 1 (one no. loose coupler conforming to IS:10124 part-V ) 1988 duly ISI marked for every 6 m. Length, required Solvent Cement for each pipe as per IS: 14128/1994 ( with latest ammendments ) up to the destination point inclusive of all charges. [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001127 | 252 | m |
16 | 16 | Supply & transportation 110 mm OD, Class - l Rigid PVC Pipes conforming to IS:4985 / 2000 ( with latest ammendments) and duly ISI marked with 1 (one no. loose coupler conforming to IS:10124 part-V ) 1988 duly ISI marked for every 6 m. Length, required Solvent Cement for each pipe as per IS: 14128/1994 ( with latest ammendments ) up to the destination point inclusive of all charges. [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001128 | 1104 | m |
17 | 17 | Supply & transportation of 110 mm OD, Class - Il Rigid PVC Pipes conforming to IS:4985 / 2000 ( with latest ammendments) and duly ISI marked with 1 (one no. loose coupler conforming to IS:10124 part-V ) 1988 duly ISI marked for every 6 m. Length, required Solvent Cement for each pipe as per IS: 14128/1994 ( with latest ammendments ) up to the destination point inclusive of all charges. [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001129 | 12 | m |
18 | 18 | Supply & transportation 140 mm dia Class-II U.P.V.C. Equal Tee.conforming to IS 10124(Part-5)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001130 | 4 | Each |
19 | 19 | Supply & transportation 110 mm dia Class-II U.P.V.C. Equal Tee.conforming to IS 10124(Part-5)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001131 | 9 | Each |
20 | 20 | Supply & transportation 140 mm dia Class-II Flanged Tail piece with metallic flange.conforming to IS 10124(Part-6)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001132 | 2 | Each |
21 | 21 | Supply & transportation 160 mm dia Class-II Flanged Tail piece with metallic flange.conforming to IS 10124(Part-6)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001133 | 9 | Each |
22 | 22 | Supply & transportation 140 X 110 mm P.V.C. (Class-II)Straight Reducer comprising of two Straight Reducer of 140x125 & 125x110 mm duly joined.conforming to IS 10124(Part-3)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001134 | 14 | Each |
23 | 23 | Supply & transportation 160 X 140 mm P.V.C. (Class-II)Straight Reducer conforming to IS 10124(Part-3)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001135 | 14 | Each |
24 | 24 | Supply & transportation 140 X 60º P.V.C. Bend(Class-II).conforming to IS 10124(Part-9)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001136 | 2 | Each |
25 | 25 | Supply & transportation 110 X 90º P.V.C. Bend(Class-II).conforming to IS 10124(Part-8)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001137 | 15 | Each |
26 | 26 | Supply & transportation 110 X 60º P.V.C. Bend(Class-II).conforming to IS 10124(Part-9)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001138 | 2 | Each |
27 | 27 | Supply & transportation 140 mm dia P.V.C. End Cap (Class-III).conforming to IS 10124(Part-4)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001139 | 2 | Each |
28 | 28 | Supply & transportation 110 mm dia P.V.C. End Cap (Class-III).conforming to IS 10124(Part-4)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001140 | 1 | Each |
29 | 29 | Supply & transportation 140 mm dia P.V.C.Extra Coupler (Class-II)conforming to IS 10124(Part-1&2)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001141 | 5 | Each |
30 | 30 | Supply & transportation 110 mm dia P.V.C.Extra Coupler (Class-II)conforming to IS 10124(Part-1&2)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001142 | 59 | Each |
31 | 31 | Supply & transportation 160 mm dia P.V.C.Extra Coupler (Class-II)conforming to IS 10124(Part-1&2)/1988 with latest amendments [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001143 | 9 | Each |
32 | 32 | Solvent Cement IS 14182/1994 with latest amendments (Meadiun Bodied) [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001144 | 5 | lts |
33 | 33 | Supply & transportation 100 mm dia Flexible PVC Suction & Delivery Hose Pipe [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001145 | 60 | m |
34 | 34 | Water Distribution Set As per Drawing and Specification for Mini RLI Scheme [Ref No. IC/AED/310 dt. 04.05.2010] Page No. 12, Item No. 10 | BI01010001010000000000000515BI0100001146 | 1 | Set |
35 | 35 | Supply & transportation 150 mm (N.B) ISI marked Sluice Valves Pressure designation P.N. 1.6 with Hand Wheel for water works purpose, C.I. flanged type conforming to IS: 14846/2000 with Amdt. No. 1&2. Components/Parts of Sluice Valves shall be manufactured from basic materials given in Table 1 of IS: 14846/2000 with Amdt. 1 & 2. The Valves shall be tested for (closed end test) against Hydrostatic test requirement. [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001147 | 2 | Each |
36 | 36 | 100mm Sluice valve :-Supply & transportation of 100mm NB ISI marked Sluice Valves Pressure designation P.N. 1.6 with Hand Wheel for water works purpose, C.I. flanged type conforming to IS: 14846/2000 with Amdt. No. 1&2. Components/Parts of Sluice Valves shall be manufactured from basic materials given in Table 1 of IS: 14846/2000 with Amdt. 1 & 2. The Valves shall be tested for (closed end test) against Hydrostatic test requirement. [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001148 | 2 | each |
37 | 37 | 100 mm Foot valve :-Supply & transportation of 100mm NB CI Flanged end & Swing type as per IS: 4038/1986 with latest amendment, duly ISI marked [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] | BI01010001010000000000000515BI0100001149 | 2 | each |
38 | 38 | 100 mm. dia Alfa Alfa valve, Type D | BI01010001010000000000000515BI0100001150 | 9 | each |
39 | 39 | M.S. Heavy Duty Hose Clamp fitted with bolt & Nuts [Ref: No. AIC/BLG/SKB/AED-PRICE/2010-11/214 Dt. 08/03/2011] 100 mm dia | BI01010001010000000000000515BI0100001151 | 20 | Each |
40 | 40 | Supply and transportation of 100 mm x 90° MS lg. ERW Priming bend B/E flanged welded are of IS : 6392/71 & MS pipe is of IS: 1239(Part-1) 04. Ref:- Page No. 15/95 of AIC/AED/310 Dt. 04/05/2010 | BI01010001010000000000000515BI0100001152 | 2 | Each |
41 | 41 | 150 mm (N.B) M.S. 90 degree Long Bend both ends flange welded, made from ERW M.S. pipes conforming toIS: 1239(Part 1)/2004, Medium quality,. The flanges are 12 mm thick, conforming to IS: 6392/71, Table-17. [Ref: No. AIC/BLG/SKB/AED-PRICE/2010-11/214 Dt. 08/03/2011] | BI01010001010000000000000515BI0100001153 | 4 | each |
42 | 42 | 100mm dia.C.I. Tail piece with Flange adopter one side groved and other end flanged.Overall length(175+/-15)mm with 7 nos groves. [Ref: No. AIC/BLG/SKB/AED-PRICE/2010-11/214 Dt. 08/03/2011] | BI01010001010000000000000515BI0100001154 | 12 | Each |
43 | 43 | M.S.Reducer 500 mm long both end flanged welded. [Ref: No. AIC/BLG/SKB/AED-PRICE/2010-11/214 Dt. 08/03/2011] 100 mm dia /75 mm dia | BI01010001010000000000000515BI0100001155 | 2 | Each |
44 | 44 | 100 mm dia /65 mm dia | BI01010001010000000000000515BI0100001156 | 2 | Each |
45 | 45 | Foundation Bolt for Distrubution Chamber (Water Distribution Unit) manufactured from 20 mm nominal diameter M.S. Rod as per IS-2062/1992.Total length of Bolt is 375+/-10 mm in length& 20 mmin nominal diameter with Nut& 2 nos WaSHER the average weight of such Bolt 1.1 kg per bolt with tolerance in weight of each Bolt @+/-10%. [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13]For Water Distribution Set | BI01010001010000000000000515BI0100001157 | 28 | Kg. |
46 | 46 | For Electric Pump Sets | BI01010001010000000000000515BI0100001158 | 8 | Kg. |
47 | 47 | M.S.Hexagonal Head Bolts & Nuts conforming to IS : 1363(Part-I)/1992 of product Grade-C with latest amendments for Bolts & IS : 1363(Part-3)/1992 of Product Grade-C with latest amendments for Nuts Properties / Class for Bolt - 4,6 & for Nut - 4,5. [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] M 20x80 mm. | BI01010001010000000000000515BI0100001159 | 152 | No |
48 | 48 | M 20x100 mm. | BI01010001010000000000000515BI0100001160 | 8 | No |
49 | 49 | M.16x65 mm | BI01010001010000000000000515BI0100001161 | 220 | No |
50 | 50 | M 16x80 mm | BI01010001010000000000000515BI0100001162 | 16 | No |
51 | 51 | M 16x 50 mm | BI01010001010000000000000515BI0100001163 | 72 | No |
52 | 52 | Foot valve Leather washer-(Best quality)\n[Ref:- Page No. 84/95 of AIC/AED/310, Dt. 04/05/2010] 100mm.dia | BI01010001010000000000000515BI0100001164 | 2 | Each |
53 | 53 | Supply of Compressed Asbestos Fibre jointing made from 5 mm thick red jointing sheet as per IS : 2712/1998 Grade W/3 FYSAX AMJ 321. Gasket for raised surface of M.S. Flange as per IS :6392/71. [Ref No. AIC/AED/25/508(50)/ MD, Dated: 29/07/13] 300mm.dia(Table-5) | BI01010001010000000000000515BI0100001165 | 3 | Each |
54 | 54 | b) Sal Wood Sleeper(4 ft x6 in x4 in) [Slg rate]\n(Item No.1 PWD Schedule) | BI01010001010000000000000515BI0100001166 | 0.072 | Cu.m |
55 | 55 | Supply & transport of Rubber Insertion 5 mm thick with proper reinforcement 2 Ply conforming to IS : 638/79 with ISI Mark with latest ammendments suitable for raised surface of M.S. Flange as per IS : 6392/71 (Table-5,11 & 17) [Ref No. AIC/AED/25/508(50)/MD, Dated: 29/07/13] 150mm.dia( Table -17) | BI01010001010000000000000515BI0100001167 | 8 | Each |
56 | 56 | 150mm.dia( Table -5) | BI01010001010000000000000515BI0100001168 | 9 | Each |
57 | 57 | 100 mm dia.(Table-17) | BI01010001010000000000000515BI0100001169 | 20 | Each |
58 | 58 | 125 mm dia.(Table-17) | BI01010001010000000000000515BI0100001170 | 2 | Each |
59 | 59 | 80 mm.dia(Table-17) | BI01010001010000000000000515BI0100001171 | 4 | Each |
60 | 60 | Supply of 16 Amp Main Switch | BI01010001010000000000000515BI0100001172 | 1 | Each |
61 | 61 | Supply of Oil Immersed Starter for 5 HP Motor | BI01010001010000000000000515BI0100001173 | 2 | Each |
62 | 62 | Supply of 4” Volt Meter (0-500V)- 2 Nos. & 4” Ammeter (0-100A)- 2 Nos. | BI01010001010000000000000515BI0100001174 | 1 | /Set |
63 | 63 | Supply of Capacitor (6 KVA) | BI01010001010000000000000515BI0100001175 | 2 | Each |
64 | 64 | Supply of Brass bar | BI01010001010000000000000515BI0100001176 | 1 | Each |
65 | 65 | Supply of wooden pannel board of size 1.5m X 1m X 0.025m with 6 Nos. M.S. clamp for Pump House wall mounting | BI01010001010000000000000515BI0100001177 | 1 | Each |
66 | 66 | Supply of 16 mm dia 3.5 Core 1100V grade PVC Copper conducter/wire | BI01010001010000000000000515BI0100001178 | 12 | Mtr. |
67 | 67 | Supply of 10 mm dia 3 Core 1100V grade PVC Copper conducter/wire | BI01010001010000000000000515BI0100001179 | 40 | Mtr. |
68 | 68 | Supply of 6 mm dia single Core 1100V grade PVC Copper conducter/wire | BI01010001010000000000000515BI0100001180 | 40 | Mtr. |
69 | 69 | Supply of 1.5 mm dia single Core 1100V grade PVC Copper conducter/wire | BI01010001010000000000000515BI0100001181 | 80 | Mtr. |
70 | 70 | Supply of Sprinkler Kit with Electric Pump Set (single phase) discharging 5.22 cubic mtr./hour at 30 mtr. Total head including accessories Kirloskar make. | BI01010001010000000000000515BI0100001182 | 1 | /Set |
71 | 71 | Tools kit comprising Slide wrench set 12" long, Ring wrench set, Side spanner set, Screw Driver 1' long, Hammer 500 Gram, Electrical Tester, Combind Pliers, Funnel 8" etc. | BI01010001010000000000000515BI0100001183 | 2 | /Set |
72 | 72 | Monoblock Surface Pump-motor set lSI marked as per IS:9079 for mini RLIscheme/ PDWwith dischargeof 13.8 Lpsat 18 mts. total head with 100 mm dia. reinforced PVCsuction pipe (20 mts. length)anddelivery pipe,foot valve, nipple, priming bend andall other accessoriescomplete. | BI01010001010000000000000515BI0100001184 | 2 | Each |
73 | 73 | Supply of Sheet metal enclosed re-wireable type Fuse, Changeover switch, 415 VOLTS, 3 phase, 50 Cycles A.C Supply conforming to IS:13947 (part-3)/1993 for-32 Amps 415 volts A.C TPN Main Switch. | BI01010001010000000000000515BI0100001185 | 2 | each |
74 | 74 | Supply of Sheet metal enclosed re-wireable type Fuse, Main switch, 415 VOLTS, 3 phase, 50 Cycles A.C Supply conforming to IS:13947 (part-3)/1993 for-100 Amps 415 volts A.C TPN Main Switch. | BI01010001010000000000000515BI0100001186 | 1 | each |
75 | 75 | Supplying of 12 mm thickness busbar (100Amps, 415Volts) chamber 450 mm x 150 mm x125mm in size fitted with 25 mm x6 mm x300 mm copper bar with 6 mm doreon plates (4bars) supplied with requisite brass nuts & bolts equivalent to bore size with at least 2 nos. of putter and 1 no inlet holes of 1-1/4" size on iron legs on w. board including arrangement of double earthing by 10 SWG GI wires. | BI01010001010000000000000515BI0100001187 | 1 | each |
76 | 76 | LAYING:- Earth work in excavation of foundation trenches of drains etc. in all sorts of soil (including mix soil but excluding laterite and sand stone) including removing spreading or stacking the spoiles, as directed and including trimming the sides of trenches (Page-1, item No.2A ,PWD) | BI01010001010000000000000515BI0100001188 | 986 | Cu.m |
77 | 77 | Laying of UPVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee Reducer etc.and making leak proof joints with couplers after roghening the surfac (Vide Page No. 134, Item No. 1 WRDD Schedules) i) 200mm dia | BI01010001010000000000000515BI0100001189 | 300 | M |
78 | 78 | ii) 140mm dia | BI01010001010000000000000515BI0100001190 | 252 | M |
79 | 79 | iii)110 mm dia | BI01010001010000000000000515BI0100001191 | 1104 | M |
80 | 80 | Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. (Page-33, Item No.1, PWD) | BI01010001010000000000000515BI0100001192 | 38.06 | Sq.m |
81 | 81 | Cement concrete (1:3:6) with graded stone ballast or local gravel 40 mm. down, excluding shuttering. In ground floor. (Page-59, Item No.10A,a PWD) | BI01010001010000000000000515BI0100001193 | 1.95 | Cu.m |
82 | 82 | Ordinary Cement concrete (1:2:4) in foundation, floor and all sorts of R.C.C works with approved graded stone chips (20mm size) excluding shuttering and re-inforcement if any, in ground floor. A) Pakur Variety (Page No.33, Item No.5A, PWD) | BI01010001010000000000000515BI0100001194 | 4.35 | Cu.m |
83 | 83 | Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering. (Page No.62 & 63, Item No.12a, PWD) | BI01010001010000000000000515BI0100001195 | 17.23 | Sq.m |
84 | 84 | Reinforcement for reinforced concrete work in all sorts of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening of bend bars excluding coil bars and removal of loose rust (if necessary) cutting to requisite length, hooking, bending to correct shape, placing in proper position and binding with 1.626 mm (16 SWG) black annealed wire at every inter section complete as per drawing and direction including cost of wire upto 1st floor level. ( For Tor steel). | BI01010001010000000000000515BI0100001196 | 0.08 | MT |
85 | 85 | Filling in foundation or plinth by fine sand in layers not exceeding 15 cm. As directed and consolidating the same by through saturation with water and ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity) (Page No.5 , Item No.4B, PWD) | BI01010001010000000000000515BI0100001197 | 5.53 | Cu.m. |
86 | 86 | Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete in foundation and plinth. (Page No.69, Item No.22a, PWD) | BI01010001010000000000000515BI0100001198 | 10 | Cu.m |
87 | 87 | 12.5 cm. thick 1st class brickwork in cement mortar (1 : 4) in ground floor including, scaffolding, racking out joints etc. complete. (Page No.73, Item No.29, PWD) | BI01010001010000000000000515BI0100001199 | 12.18 | Sq.m |
88 | 88 | Labour charges for fitting and fixing and laying of MS/ERW pipe both ends flanged including cutting threading etc. and making leak proof joints by using rubber insertion, nuts and bolts (all materials including pipes to be supplied departmentally (Vide Page No. 134, Item No. 2 (i) (ii), WRDD Schedules) a) 150mm dia ERW pipes | BI01010001010000000000000515BI0100001200 | 48 | m |
89 | 89 | b) 100mm dia (NB) ERW/MS pipes | BI01010001010000000000000515BI0100001201 | 24 | m |
90 | 90 | 15 mm thick plaster (to wall, floor, ceiling etc.) with (1:6) sand and cement mortar including rounding off or chamfering corners, as directedand racking out joints or roughening of concrete surface including throating. Nosing and drip course as necessary (Page No.319, Item No.2 (i),C), PWD) | BI01010001010000000000000515BI0100001202 | 105.3 | Sq.m |
91 | 91 | Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete. (Page No.323, Item No.8, PWD) | BI01010001010000000000000515BI0100001203 | 105.3 | Sq.m |
92 | 92 | Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 15 cm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation. (Page No.3, Item No.3(a) PWD) | BI01010001010000000000000515BI0100001204 | 962 | Cu.m |
93 | 93 | Erection, fitting and fixing set of M.S Water Distribution Unit inlet and outlet pipe fittings (Rate inclusive of transportation from Deptt. Store to work site ). (Page No.137, Item No. 14, WRDD) | BI01010001010000000000000515BI0100001205 | 1 | Set |
94 | 94 | Priming one coat on steel or other metal surface with synthetic oil\nbound primer of approved quality including smoothening surfaces by sand papering etc\n | BI01010001010000000000000515BI0100001206 | 20 | m2 |
95 | 95 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :\n (b) On steel or other metal surface :\nWith super gloss (hi-gloss) -\n (iv) Two coats (with any shade except white) | BI01010001010000000000000515BI0100001207 | 20 | m2 |
96 | 96 | Labour charges for fitting, fixing 125 mmx150 mm dia MS expander with 140 mm dia UPVC pipe with the help of PVC flanged Tail piece by jointing flanged end of the tail piece and 140 mm NB end of expander with rubber insertion with nuts and bolts Etc. all complete (Page No.137, Item No. 9, WRDD Schedules) | BI01010001010000000000000515BI0100001208 | 2 | Each |
97 | 97 | Labour charges for fitting and fixing 110 mm. dia Flap valve with 110 mm. dia Class-II UPVC riser / Pipe with 100 mm dia . AC resure pipe with the help of FTP (Flanged Tail Piece ) y joining the PVC/ACP end of the tail piece and riser pipe with coupler and flanged end of tail piece and Flap Valve with rubber insertion, nuts and bolts etc. complete. (Rate inclusive of transportation from departmental store to work site). | BI01010001010000000000000515BI0100001209 | 9 | Each |
98 | 98 | Fitting and fixing of M.S/G.I/C.I accessories and specials( accessories and specials to be supplied departmentally)including supply of jointing material viz. bolts and nuts, rubber insertion and havoc zink etc complete as per direction of E.I.C. (Page No.140, Item No. 7, WRDD) i).150 mm dia 90º MS Bend with flanged ends | BI01010001010000000000000515BI0100001210 | 4 | Each |
99 | 99 | ii) 150 nmm NB CI Sluice valve | BI01010001010000000000000515BI0100001211 | 2 | Each |
100 | 100 | ii) 100 nmm NB CI Sluice valve | BI01010001010000000000000515BI0100001212 | 2 | Each |
101 | 101 | Transportation of Diesel pump set/ motor pumping set for MINI RLI any make/brand with necessary fixture VIZ. MS bend, MS pipe, Rubber Holes Pipe,manifold, saurge tank, foot vulve, non return vulve, tail pieces, sluice vulve, priming chamber etc. over pucca/ Kuchcha road from Sub-Divisional. store to work side excluding loading at lifting point & unloading at delivery point. (Page No.168, Item No. 16(c), WRDD) (a) Carriage by Road distance upto 50 Km. | BI01010001010000000000000515BI0100001213 | 2 | Each set |
102 | 102 | Placing and positioning the Centrifugal pump motor set on the pump base/pump house floor, alligning properly with necessary packing and fixing the set with holding down nuts and washer Including cutting holes or requisite size in the floor / base, grouting the bolts and mending good all damages-complete as per direction of Engineer-in-Charge. (Page No.147, Item No. 1, WRDD)\n(i) 5 H.P. Capacity | BI01010001010000000000000515BI0100001214 | 2 | Each Set |
103 | 103 | Testing of Pipe line system against leakage by filling the distribution chamber with water and supplying water through the entire pipe line network for at least 4(four) hours by running the departmental diesel Engine pumping set including supplying necessary fuels lubricants grease, gland packing etc. and hiring and transporting tool and plants all complete as per direction of EIC. (Page No.136, Item No. 7(b) (iii), WRDD) | BI01010001010000000000000515BI0100001215 | 1 | L.S |
104 | 104 | Supplying, fitting and fixing including transportation of sign board for identifying the exact location of RLI scheme (one at rode side and other at site) the board will be made 3mm thick MS plate and fitted and fixed on 50mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writing of both sides of Sign board. Base- Yellow, and ward – Red. Both bottom end of the stands pipe will be grouted in 1:2:4 cc on a single brick flat soiling. This will include one material and labour complete as per drawing and direction of EIC. (Page No.138, Item No. 17, WRDD) | BI01010001010000000000000515BI0100001216 | 1 | L.S. |
105 | 105 | Suppling 1 mtr x 0.6 m x 24 swg MS board containing list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour – Black and words – White to be fitted and fixed on the wall of the pump house. (Page No.138, Item No. 18, WRDD) | BI01010001010000000000000515BI0100001217 | 1 | LS |
106 | 106 | PUMP HOUSE :- Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm | BI01010001010000000000000515BI0100001218 | 9.38 | m³ |
107 | 107 | Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150 mm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation. | BI01010001010000000000000515BI0100001219 | 7.27 | m³ |
108 | 108 | Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. | BI01010001010000000000000515BI0100001220 | 6.73 | m³ |
109 | 109 | Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. | BI01010001010000000000000515BI0100001221 | 26.43 | m² |
110 | 110 | Cement concrete (1:3:6) with graded stone ballast or local gravel 40 mm. down, excluding shuttering in ground floor. | BI01010001010000000000000515BI0100001222 | 1.35 | m³ |
111 | 111 | Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding Brick work with Ist class brick in cement mortar (1 : 6). (a) In foundation and Plinth | BI01010001010000000000000515BI0100001223 | 6.34 | m³ |
112 | 112 | (b) In superstructure , ground floor | BI01010001010000000000000515BI0100001224 | 2.8 | m³ |
113 | 113 | 12.5 cm. thick 1st class brickwork in cement mortar (1 : 4) in ground floor including, scaffolding, racking out joints etc. complete. | BI01010001010000000000000515BI0100001225 | 38.19 | m² |
114 | 114 | 25 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over\ntwo coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid\nseperately) for underground water retaining structures. [water proofing as per item no 60 and non toxic paint as per Item No. 59 (b) of Section 'C' ] | BI01010001010000000000000515BI0100001226 | 3.54 | m² |
115 | 115 | Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(d) With local hard blackstone variety chips.d) With local hard backstone variety chips (crusher broken) | BI01010001010000000000000515BI0100001227 | 3.49 | m³ |
116 | 116 | Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30.0 mm. thick wooden shuttering. | BI01010001010000000000000515BI0100001228 | 23.38 | m² |
117 | 117 | Reinforcement for reinforced concrete work in all sorts of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening of bend bars excluding coil bars and removal of loose rust (if necessary) cutting to requisite length, hooking, bending to correct shape, placing in proper position and binding with 1.626 mm (16 SWG) black annealed wire at every inter section complete as per drawing and direction including cost of wire upto 1st floor level. ( For Tor steel). | BI01010001010000000000000515BI0100001229 | 1.37 | Qtl. |
118 | 118 | Plaster (to wall, floor ceiling etc) with sand and cement mortar including rounding off or chamfering corners, as directed and racking out joints or roughening of concrete surface including throating, nosing and drip course , scaffolding/ staging as necessary at ground floor. (Excluding cost of chipping over concrete surface) (a) with (1:6) cement mortar , 20 mm. thick plaster. | BI01010001010000000000000515BI0100001230 | 31.65 | m² |
119 | 119 | (b) with (1:6) cement mortar , 15 mm. thick plaster. | BI01010001010000000000000515BI0100001231 | 43.5 | m² |
120 | 120 | (c) with (1:4) cement mortar , 10 mm. thick plaster. | BI01010001010000000000000515BI0100001232 | 17 | m² |
121 | 121 | Grey artificial stone in floor, dado,staircase etc. with cement concrete 1:2:4 with stone chips laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion that 1:2 including smooth finishing and rounding off corners including raking of joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour . In ground floor. 3.00 mm.thick topping ( high polishing , grinding on these item is not permitted with ordinary cement). Using grey cement (ii) 25 mm thick. | BI01010001010000000000000515BI0100001233 | 11.77 | m² |
122 | 122 | Neat cement punning about 1.5 mm. thick in wall dado,floor, drain, door and window sill etc. complete. | BI01010001010000000000000515BI0100001234 | 33.92 | m² |
123 | 123 | M.S. gate of Jail type as per approved design made of strong M.S. frame work intermediate stiffeners and round / square bars or angles. M.S. Sheet (not less than 14 gauge) gussets, cleats etc including necessary riveting, bolting, welding, locking and hanging etc.complete. | BI01010001010000000000000515BI0100001235 | 2.6 | sqm |
124 | 124 | Supplying, fitting & fixing windows and vatilator with or without intigrated grills confirming to IS 1038-1975 and manufacturered from roll steel section conforming to IS 7452-1974 with non fixtion projecting type, box type hings glazing clips, lugs locking bracket, handle plate etc., including hoisting in position strenghtening if required, fixing lugs in cement concretre (1:2:4) with stone chips 20 mm down cutting hole and manding good damages to match with exting surface complete in all respect excluding glazing in ground floor.\nFlash butt welded windows and vantilators\n(b) Openable steel windows as per IS sizes with side hung shutters on horizental glazing bars with/without fix type vantilator (the extra rate admissible for openble portion only) | BI01010001010000000000000515BI0100001236 | 2.24 | m² |
125 | 125 | MS integrated grill as per approved design integrated with steel window or vantilators joints contiously welded with MS flats and bars. | BI01010001010000000000000515BI0100001237 | 36.8 | Kg. |
126 | 126 | Supplying 1.5 mm thick MS sheet fitted and fixed on one or both faces of MS/WI gate etc with point welding at not more than 150 mm apart complete in all repect as per design including cost of all labour and materials. | BI01010001010000000000000515BI0100001238 | 3.24 | sqm |
127 | 127 | Supplying ,fitting, fixing UPVC Pipes A type and fittings conforming to IS: 13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cuting treches in any soil through masonry concrete structures etc. if necessary and manding a good damage including jointing materials (Spun yarn, valamoid/Bitumen/M-seal etc.) complete.A) UPVC Pipes: ii) 110 mm.dia | BI01010001010000000000000515BI0100001239 | 3 | Mtr. |
128 | 128 | Supplying fitting approved type ventilator in position after cutting holes in walls, setting in cement mortar, mending damages to wall and plaster two coats of paint of approved brand sand shade. Payment of mending two damages of wall & plaster and painting to be mase seperately.b) RCC ventilator of 20 mm thick upto 0.10 sqm area | BI01010001010000000000000515BI0100001240 | 6 | Each |
129 | 129 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc including using of approved putty etc on the surface, if necessary. (b) On steel surface (Normal gloss).Two coats (with any shade except white). | BI01010001010000000000000515BI0100001241 | 16.93 | m² |
130 | 130 | White washing including cleaning and smoothening surface thoroughly. (c) Three coats (on new work only) | BI01010001010000000000000515BI0100001242 | 98.57 | m² |
131 | 131 | Colour washing with "ELLA" with a coat of white wash priming including cleaning and smoothening surface thoroughly(ii) External surface( Ground floor) (b) Two coats | BI01010001010000000000000515BI0100001243 | 72 | m² |
132 | 132 | Rough dressed timber planks fitted and fixed with nut bolts excluding framework complete: In Ground floor iv)above 50 mm thick planks (b) Sal local | BI01010001010000000000000515BI0100001244 | 0.05 | cum |
133 | 133 | INTERNAL WIRING:-Supply, Fitting & fixing of DPIC main switch 15/16 A 250 Volts (Havells )on Iron legs on wall including mending good the damage for light circuit of pump house (PWD elec. Sh. Page-D-1,item -A1) | BI01010001010000000000000515BI0100001245 | 1 | Each |
134 | 134 | Supply, Fitting & fixing of 250 volts, 15/16A per way iron clad BDB (2 way) with fuses on flat iron/angle iron frame on wall (Havells) (PWD elec. Sh. Page-D-2,item-6a) | BI01010001010000000000000515BI0100001246 | 1 | each |
135 | 135 | Supply, Fitting & fixing of 228 long X15.8mm dia heavy guage swan brass bracket with bakelite holder (PWD elec. Sh. Page-D-5,item-7) | BI01010001010000000000000515BI0100001247 | 2 | each |
136 | 136 | Supply, Fitting & fixing of bulk head light fitting on wall/ceiling including S/F suitable 25 wattas CFL lamps complete with glass wire guard and holder (PWD elec. Sh. Page-D-6,item-b14) | BI01010001010000000000000515BI0100001248 | 2 | each |
137 | 137 | Wiring from 15/16A DPIC main switch to Busbar box in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Branded) of 2X 36/0.3(2.5 Sq. mm) + 1 X 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including supply, necessary PVC clips,fittings etc. (PWD elec. Sh. Page-E-19,,item-B1) | BI01010001010000000000000515BI0100001249 | 1 | RMeter |
138 | 138 | Wiring from 15/16A DPIC main switch to BDB in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Branded) with 2X 36/0.3(2.5 Sq. mm) + 1 X 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including supply, necessary PVC clips,fittings etc. (PWD elec. Sh. Page-E-19,,item-B1) | BI01010001010000000000000515BI0100001250 | 6 | RMeter |
139 | 139 | Distribution wiring in 1.1KV grade 2X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Branded) with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including supply, necessary PVC clips,fittings etc. to light/fan/calling bell with piano key type switch of (Anchore make/any similar branded) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works.[PVC casing capping and switch board botyh on surface] average run 5 meter (PWD elec. Sh. Page-E-19,,item-B2) | BI01010001010000000000000515BI0100001251 | 4 | Point |
140 | 140 | Distribution wiring in 1.1KV grade 2X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Branded) with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including supply, necessary PVC clips,fittings etc. to 5amps 3 pin flush type plug socket with piano key type switch of (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works.[PVC casing capping and switch board botyh on surface] average run 1.5 meter (PWD elec. Sh. Page-E-20,,item-B6b) | BI01010001010000000000000515BI0100001252 | 1 | Point |
141 | 141 | MOTOR INSTALATION & WIRING: Fitting & fixing of 63 A 500 V iron clad/ sheet steel TP/ TPN main switch on iron legs on wall (PWD elec. Sh. Page-C-1,item-1) | BI01010001010000000000000515BI0100001253 | 1 | each |
142 | 142 | Fitting & fixing of 32 A 500 V iron clad/ sheet steel TP/ TPN main switch/isolators on iron legs on wall (PWD elec. Sh. Page-C-1,item-1) | BI01010001010000000000000515BI0100001254 | 2 | each |
143 | 143 | Fitting & fixing of only 63 A 500V iron clad M.S. sheet metal busbar chamber on angle iron frame on wall for 4 bars 63Amps (PWD elec. Sh. Page-C-2,item-8) | BI01010001010000000000000515BI0100001255 | 1 | each |
144 | 144 | Fitting & fixing of Star Delta starter (for 10 HP motor contol) on angle iron frame on wall (PWD elec. Sh. Page-C-2,item-9b) | BI01010001010000000000000515BI0100001256 | 2 | each |
145 | 145 | Fitting & fixing of Volt meter and Ammeter with necessary screws and other fixing materials including making holes where necessary and making connections (PWD elec. Sh. Page-C-2,item-13) | BI01010001010000000000000515BI0100001257 | 3 | each |
146 | 146 | Fitting & fixing of Capacitor Bank(5 KVAR ,500V) and single phase preventer with necessary screws and other fixing materials including making holes where necessary and making connections | BI01010001010000000000000515BI0100001258 | 3 | each |
147 | 147 | Drawing, supplying fitting & fixing of meter loop with 4 x 19/0.044"( Branded) copper wire single core 660 volt grade in 1 1/2" PVC conduit/ flexible pipe fitted and fixed with accessory bends and elbows, covers etc. with saddle on wall from 63 amp 500 volt TPN IC switch to Supply meter with all inter connectiosn conforming to IEE regulation. | BI01010001010000000000000515BI0100001259 | 1.5 | RMeter |
148 | 148 | Drawing, supplying fitting & fixing of meter loop with 4 x 19/0.044"( Branded) copper wire single core 660 volt grade in 1 1/2" PVC conduit/flexible pipe fitted and fixed with accessory bends and elbows, covers etc. with saddle on wall from 63 amp 500 volt TPN IC switch to Busbar with all inter connectiosn conforming to IEE regulation. | BI01010001010000000000000515BI0100001260 | 1 | RMeter |
149 | 149 | Drawing, supplying fitting & fixing of meter loop with 3 x 7/0.036"( Branded) copper wire single core 660 volt grade in 1 1/2" PVC conduit/flexible pipe fitted and fixed with accessory bends and elbows, covers etc. with saddle on wall from 32 amps 500 volt TPN IC switch to Busbar with all inter connectiosn conforming to IEE regulation. | BI01010001010000000000000515BI0100001261 | 1 | RMeter |
150 | 150 | Drawing, supplying fitting & fixing of meter loop with 3 x 7/0.036"( Branded) copper wire single core 660 volt grade in 1 1/2" PVC conduit/ flexible pipe fitted and fixed with accessory bends and elbows, covers etc. with saddle on wall from 32 amps 500 volt TPN IC switch to Star Delta Starters with all inter connectiosn conforming to IEE regulation. | BI01010001010000000000000515BI0100001262 | 1.5 | RMeter |
151 | 151 | Drawing, supplying fitting & fixing of meter loop with 6 x 7/0.036"( Branded) copper wire single core 660 volt grade in 1 1/2" PVC conduit pipe fitted and fixed with accessory bends and elbows, covers etc. with saddle on wall from Star Delta Starters to motors with all inter connectiosn conforming to IEE regulation. | BI01010001010000000000000515BI0100001263 | 14 | RMeter |
152 | 152 | Drawing, supplying fitting & fixing of meter loop with 3 x 7/0.036"( Branded) copper wire single core 660 volt grade in 1 1/2" PVC conduit/ flexible pipe fitted and fixed with accessory bends and elbows, covers etc. with saddle on wall from Star Delta Starters to Capacitor bank with all inter connectiosn conforming to IEE regulation. | BI01010001010000000000000515BI0100001264 | 1.5 | RMeter |
153 | 153 | Suppling & fitting & fixing of danger Board (mannual) 4"x6" in two distinguishing position in the door of pump house (outside) and at the palce of panel board | BI01010001010000000000000515BI0100001265 | 2 | each |
154 | 154 | Suppling fitting & fixing of shock treatment chart in a wooden frame with brass. | BI01010001010000000000000515BI0100001266 | 1 | each |
155 | 155 | Earthing with 50 mm (2") dia Galvanized iron pipe 3.64 mm thick X 3.04 mtr.(10ft) long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm (1/2") dia X80 mm (3") long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. (12") below the ground level and restoring the surface duly rammed for Soft/Morrum soil by ISI-Medium G.I. Pipe (PWD elec. Sh. Page-G-1,item-2) | BI01010001010000000000000515BI0100001267 | 2 | set |
156 | 156 | Supplying and fixing earth bar of galvanized M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilloed holes (on busbar) about 3 cm. apart complete with G.I. bolts, nuts, washers etc. as required for tapping.(PWD elec. Sh. Page-G-3, item-4a) | BI01010001010000000000000515BI0100001268 | 0.3 | Meter |
157 | 157 | Connecting the equipments to earth busbar including supplying and fixing G.I. Wire No. 10 SWG on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages. | BI01010001010000000000000515BI0100001269 | 20 | Meter |
158 | 158 | Submission of test form in the prescribed form obtaining from WBSEB after mager test by a licenced Electrical supervisor and contractor having competency certificate in part - I,II,XI,III,IV,V,VI-A/VI-B/VIII-A and VII-B | BI01010001010000000000000515BI0100001270 | 1 | item |
159 | 159 | Distribution wiring with 660 v grade single core cupper conductor PVC insulated and unshared in flexible conduita) 3x10sq.mm pvc insulated on conductor in 30mm flex conduit pipe coupling at ends from 100amps main switch to bus-bar chamber leads end to be socketted. | BI01010001010000000000000515BI0100001271 | 1.5 | mtr. |
160 | 160 | Solar Module: Supply , transport , installation and commissioning of MNRE (Ministry of Renewable Energy, Govt. of India)/ IEC approved Solar Module of multicrystaline cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2mm tempered glass , framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances. Modules supplied with the SPV system should have certificate as per IEC 61215 specification or equivalent National or International standards. Modules must qualify to IEC 61730 part I and part II for safety qualification testing and Salt Mist Corrosion Testing as per IEC 61701 /IS 61701.and having warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied. c) For 10 HP Off-grid Solar Water Pumping System - 10880Wp - 11050Wp with 320 / 325 Wp SPV Panel. | BI01010001010000000000000515BI0100001272 | 11050 | Wp |
161 | 161 | Module Mounting Structure ( For 10HP Solar Water Pumping System): \nSupply, transport , installation of weather proof manual tracking structure made of MS channels, angles and pipes etc duly IS marked channels, angles( IS 808 ) to hold SPV Module with MS heavy duty pipes not less than F125 mm as per IS 1239 and plates of IS 226. Structure like Canopy supported with a RCC column is to be installed to limit land requirement with a height of placement of panel for free human movement and natural air cooling will be happening to get the maximum efficiency from the modules. This structure to be designed considering all the possible loads on the solar panels and on the structure itself including wind load with basic wind velocity 150km/hr. The steel structure of suitable size is to be protected with minimum 80 micron galvanisation and provided with dual axis manual tracking arrangement three times in a day and seasonal tilting are to be provided to face the sun optimally. | BI01010001010000000000000515BI0100001273 | 1380 | Kg |
162 | 162 | Foundation of Module Mounting Structure: \nSuitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking SPV Module structure as per approved drawing. a) For 6 module structure having maximum capacity of 1950Wp | BI01010001010000000000000515BI0100001274 | 6 | set |
163 | 163 | Power conditioning unit including MPPT , Data logger and IP54 enclosure : \nSupply , transport , installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 600682-Environment Standard, safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc . The system should be capable to store the data at a set interval and transfer it in a pendrive through USB port . It should also monitor and save total run time, total water pumped etc . There should be provision for interfacing GPRS based data transmission. c) For 10 HP capacity Pump-motor set. | BI01010001010000000000000515BI0100001275 | 2 | set |
164 | 164 | Cable and Accessories :\nSupplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc.\ni. 4.0 Sq mm single core multi studs - 10 Mtrs (Minimum)\nii. 6.0 Sq mm single core multi struds -5 Mtrs (Minimum)\niii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc c) For 10 HP per structure | BI01010001010000000000000515BI0100001276 | 6 | set |
165 | 165 | Earthing: \nEarthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:\nBy ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. | BI01010001010000000000000515BI0100001277 | 6 | set |
166 | 166 | Lighting System at Scheme: (Mounted on Pump House wall) :\nlighting arrangement with Solar Battery 12 V, 40 Ah (reputed brand- tubular type), Charge controller, 50 Wp solar panel, LED 11 watt 12 volt. Battery and Charge controller to be mounted in a kiosk box of thickness 14 swg powder coated painted which is to be fitted at the bottom of the light post at man height fitted on wall with MS angles at pump house wall. | BI01010001010000000000000515BI0100001278 | 1 | set |
167 | 167 | Lightning protection (Pole mounted): \nLightning protection with 3" X 1.5" G.I pipe of 4 mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge\nprongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Provision of one lightning protection for each structure). | BI01010001010000000000000515BI0100001279 | 6 | set |
168 | 168 | Testing and commissioning of scheme after completion of all work | BI01010001010000000000000515BI0100001280 | 1 | item |
169 | 169 | Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time) c) For 10 HP both for Submersible & Surface pump Note: Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit. Security Deposit will be released after expiry of warranty period of 1 year & Comprehensive maintenance charges will be released @ Rs.1.25 per Wp per year at the end of each maintenance period i.e.at the end of 2nd year, 3rd year, 4th year, 5th year. In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited | BI01010001010000000000000515BI0100001281 | 11050 | Wp |
170 | 170 | Remote monitoring for 5 years: \nSupply & installation of GSM/GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameters to central server from the Solar pumping System with time stamp at user-defined interval and report generation at the buyer end. | BI01010001010000000000000515BI0100001282 | 1 | set |
171 | 171 | Insurance @ 2% for Item No. 1, 4, 8 for a period of 5 years.\nNote:\nIst year's Insurance charge is to be paid on production of Original Receipt of premium payment. Remaining 4 years Insurance payment is to be withheld which will be released during 2nd, 3rd , 4th & 5th year on production of Original Receipt of premium payment. | BI01010001010000000000000515BI0100001283 | 1 | item |
172 | 172 | Charges for jointing water proof cable with required water proof insulation and proper jointing compound including supply of other related materials, complete in all respect. | BI01010001010000000000000515BI0100001284 | 3 | points |
173 | 173 | Supplying, fitting & fixing of MS Plateof size 20cmx20cm, 6 mm thick make of two halves(20 cmx10cm) placed over housing pipe of LDTW to rest the supporting clamps,with semi circlar hole of 90 mm dia at centre including locking arrangement between the two halves on both sides, including fitting, fixing of 25mm dia G.I. bend by making a hole on plate for passing submersible cable smoothly and complete in all respect. | BI01010001010000000000000515BI0100001285 | 1 | each |
174 | 174 | Transportation of 3CX2.5 sq Flat cable, 75mm Lay Flat hose pipe, from resources Subdivisional store to work site within 100km distance | BI01010001010000000000000515BI0100001286 | 1 | item |
175 | 175 | Supplying MS Hexagonal Head Bolts & Nuts bearing IS-1363 (Part-I)/1992 of product Grade- C with latest amendments for bolts & ISIS-1363 (Part-3)/1992 of product Grade-C with latest amendments | BI01010001010000000000000515BI0100001287 | 6 | kg |
176 | 176 | Supplying and fixing medium gauge G.I. Pipe (ISI-Medium) protection with necessary fittings and jointing materials. a) 25 mm dia. (G.I. Pipe for passing cable) | BI01010001010000000000000515BI0100001288 | 4 | m |
177 | 177 | Extra for AC card in Power conditioning Unit | BI01010001010000000000000515BI0100001289 | 1 | each |
178 | 178 | 64A 3pole Change over Switch for selection of solar/grid power | BI01010001010000000000000515BI0100001290 | 1 | each |
179 | 179 | Earth work in excavation of foundation trenches or drains in all sorts of soil ( including mixed soil but excluding laterite and sand stone), including removing, spreading, or stacking the spoils, within a lead of 75m as directed and including trimming the sides of trenches, levelling, dressing and ramming the bottoms, bailing or pumping out water etc.as required complete, box cutting of 0.75m x 0.75m has to be done at every alternate joints of the pipe. Depth of | BI01010001010000000000000515BI0100001291 | 270 | Cum |
180 | 180 | Earth work in filling of foundation trenches or plinth with good earth in layer not exceeding15 cm . Including watering and ramming etc .layer by layer complete with earth obtain from excavation of foundation . (Page No.3, Item No.3a, PWD) | BI01010001010000000000000515BI0100001292 | 263.88 | Cum |
181 | 181 | Supply & fitting Pr. Gauge: supply of best quality Pr. Gauge (0-10 kg/cm2) | BI01010001010000000000000515BI0100001293 | 2 | each |
182 | 182 | Add 4% Extra for WATER TRANSMISSION ARRANGEMENT ON (Sl No.76-105), Except Earth Cutting In Excavation &Filling ( Sl No-76&92) | BI01010001010000000000000515BI0100001294 | 1 | L.S. |
183 | 183 | Add 4% Extra for PUMP HOUSE ON (Sl No.106-132),Except Earth Cutting In Excavation &Filling (Sl No-106&107) | BI01010001010000000000000515BI0100001295 | 1 | L.S. |
184 | 184 | Add GST @12% ON (Sl No.76-181) | BI01010001010000000000000515BI0100001296 | 1 | L.S. |
185 | 185 | Add labour welfare cess @ 1% ON (Sl No.76-181)total with GST | BI01010001010000000000000515BI0100001297 | 1 | L.S. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy