Implementation Of Garara Midi Rli Under Ranibandh Block Under Bankura-Ii Sub Division Under Bankura ( Am ) Division Under Jap Programme 2020-21, Bankura-West Bengal

Water Resources Department-WRD has published Implementation Of Garara Midi Rli Under Ranibandh Block Under Bankura-Ii Sub Division Under Bankura ( Am ) Division Under Jap Programme 2020-21. Submission Date for this Tender is 13-02-2021. Lift Irrigation Tenders in Bankura West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

26661056
Corrigendum : Implementation Of Garara Midi Rli Under Ranibandh Block Under Bankura-Ii Sub Division Under Bankura ( Am ) Division Under Jap Programme 2020-21
Open Tender
Indian
West Bengal
Bankura
13-02-2021

Tender Details

Implementation Of Garara Midi Rli Under Ranibandh Block Under Bankura-Ii Sub Division Under Bankura ( Am ) Division Under Jap Programme 2020-21

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Feb-2021 BID SUBMISSION CLOSING DATE HAS BEEN EXTENDED Date 13-02-2021

Key Value

Document Fees
Refer document
EMD
INR 62249.0 /-
Tender Value
INR 31.12 Lakhs /-

BOQ Items

Name of Work:- Implementation of GARARA Midi RLI under RANIBANDH Block Under Bankura-II Sub Division under Bankura(AM) Division Under JAP Programme 2020-21
Sl. No. Item Description Item Code / Make Quantity Units
1 1 DBMS& WUA Conduct of an awarness meeting among villagers for mobilazation of community towards formation of a committee for sustainability of the irigation structure in future.the expenses of the programme head as follows .meeting arangement,tea,and biscuits,travelling expens,service charge etc. BI01010001010000000000000515BI0100001113 1 Each Side
2 2 preparation the documents of the association of water users for WUA registration Act 1961 . The expences of the programme head as follows typing,printing,Preapration of the set documents service charge etc BI01010001010000000000000515BI0100001114 1 Each Side
3 3 field visit for signature of the registration paper of the WUA members. The expences of the programme head as follows.Travelling expences,service charge etc. BI01010001010000000000000515BI0100001115 1 Each Side
4 4 Preparation of the whole registration documents with authorization paper by WUA and department.The expences of the programme head as follows.typing,Printing,Preparation of the set documents,service charge etc. BI01010001010000000000000515BI0100001116 1 Each Side
5 5 Submission of the registration documents of WUAat kolkta for getting registration certificate under society registration act 1961.The expences of of the programme head follows travelling expences, food and lodging expences to kolkata and return ,service charge etc. BI01010001010000000000000515BI0100001117 1 Each Side
6 6 Participation in hearing for WUA registration confirmation at society registration office.the expences of the programme head as follows. Travelling expences, food and lodging expences to kolkata and return ,service charge etc. BI01010001010000000000000515BI0100001118 1 Each Side
7 7 collection of WUA certificate. The expences of the programme Head as follows Travelling expences, food and lodging expences to kolkata and return ,service charge etc. BI01010001010000000000000515BI0100001119 1 Each Side
8 8 Conduct of an awarness meeting among villagers for collection of mouza map including spout wise list of benificiary with plot number & quatity of irrigated area for each farmer for sustainability of the irigation structure in future.the expenses of the programme head as follows .meeting arangement,tea,and biscuits,travelling expens,service charge etc. BI01010001010000000000000515BI0100001120 1 Each Side
9 9 Preparation the documents of the association of list of benificiary with benifitted area agaist each spout . The expences of the programme head as follows typing,printing,Preapration of the set documents service charge etc BI01010001010000000000000515BI0100001121 1 Each Side
10 10 Field visit for for cross check up of spout wise benificiary list including their area to be irrigated. The expences of the programme head as follows.Travelling expences,service charge etc. BI01010001010000000000000515BI0100001122 1 Each Side
11 11 Collection of data like plot number, latitude & lognitude of P.H., D.C., & each spout & Preparation of documents & submission of same to the office in duplicate.The expences of the programme head as follows.Collecting,typing,Printing,Preparation of the set documents,service charge etc. BI01010001010000000000000515BI0100001123 1 Each Side
12 12 Collection of phatography like prework, ongoing & post work covering lay-out,pipe trenches,trenches with pipe before earth filling, measurment ,final work with name plate, & submission of same to the office in duplicate.The expences of the programme head as follows.Collecting,typing,Printing,Preparation of the set documents,service charge etc. BI01010001010000000000000515BI0100001124 1 Each Side
13 13 Submission of soft copy( by a DVD) of all above data like spout wise benificiary list including area of irrigated land of each farmer, phtography, latlong of P.H., D.C.,& each spout chamber in duplicate. the programme head as follows Preparation of the set documents,service charge etc. BI01010001010000000000000515BI0100001125 1 Each Side
14 14 MATERIAL :- Rigid P.V.C. pipes with one loose coupler for every 6.0 mtr. Length and solvent cement accordingly to technical specification as per I.S.No. 4985/2000 with latest amendments and duly I.S.I. certification marked & CIPET tested. A)200 mm.dia Class-I (0.25 MPA) BI01010001010000000000000515BI0100001126 1200 Mtr.
15 15 140 mm.dia Class-I (0.25 MPA) BI01010001010000000000000515BI0100001127 1998 Mtr.
16 16 160 mm.dia Class-II (0.40 MPA) BI01010001010000000000000515BI0100001128 18 Mtr.
17 17 Rigid P.V.C. Accessories of Class-II (0.4 MPA) according to Technical specification as per relevant IS Code with latest amendment & duly I.S.I. certification marked & CIPET tested. A)200 mm.dia F.T.P. with Metallic flange BI01010001010000000000000515BI0100001129 5 NOS
18 18 160 mm.dia F.T.P. with Metallic flange BI01010001010000000000000515BI0100001130 17 Nos.
19 19 200 mm.dia 900 Bend BI01010001010000000000000515BI0100001131 2 Nos.
20 20 140 mm.dia 900 Bend BI01010001010000000000000515BI0100001132 20 Nos.
21 21 140 mm.dia 600 Bend BI01010001010000000000000515BI0100001133 9 Nos.
22 22 200 mm.dia 450 Bend BI01010001010000000000000515BI0100001134 2 Nos.
23 23 200 x 140 mm.dia Reducer BI01010001010000000000000515BI0100001135 9 Nos.
24 24 200 x 160 mm.dia Reducer BI01010001010000000000000515BI0100001136 4 Nos.
25 25 160 x 140 mm.dia Reducer BI01010001010000000000000515BI0100001137 13 Nos.
26 26 200 mm.dia Equal Tee BI01010001010000000000000515BI0100001138 5 Nos.
27 27 140 mm.dia Equal Tee BI01010001010000000000000515BI0100001139 13 Nos.
28 28 200 mm.dia End cap, Class-III BI01010001010000000000000515BI0100001140 2 Nos.
29 29 200 mm.dia Extra Coupler BI01010001010000000000000515BI0100001141 20 Nos.
30 30 160 mm.dia Extra Coupler BI01010001010000000000000515BI0100001142 18 Nos.
31 31 140 mm.dia Extra Coupler BI01010001010000000000000515BI0100001143 70 Nos.
32 32 140 mm.dia End Cap, Class - III BI01010001010000000000000515BI0100001144 2 Nos.
33 33 Solvent cement conforming to I.S. No. 14128/94 with latest amendments, Medium Bodies. BI01010001010000000000000515BI0100001145 15 Ltr.
34 34 Solvent cement conforming to I.S. No. 14128/94 with latest amendments, Heavy Bodies. BI01010001010000000000000515BI0100001146 5 Ltr.
35 35 100 mm.dia Flexible PVC Hose for Suction & Delivery line with ISI certification marked & CIPET tested. BI01010001010000000000000515BI0100001147 60 Mtr.
36 36 Rubber Insertion, duly, reinforced 5 mm.thick 2 plies as per I.S.No.-6392 with latest amendments.300 mm.dia (Table-17) BI01010001010000000000000515BI0100001148 4 Nos.
37 37 300 mm.dia (Table-5) BI01010001010000000000000515BI0100001149 4 Nos.
38 38 200 mm.dia (Table-11) BI01010001010000000000000515BI0100001150 3 Nos.
39 39 200 mm.dia (Table-5) BI01010001010000000000000515BI0100001151 6 Nos.
40 40 150 mm.dia (Table-17) BI01010001010000000000000515BI0100001152 26 Nos.
41 41 150 mm.dia (Table-5) BI01010001010000000000000515BI0100001153 6 Nos.
42 42 125 mm.dia (Table-17) BI01010001010000000000000515BI0100001154 13 Nos.
43 43 100 mm.dia (Table-17) BI01010001010000000000000515BI0100001155 12 Nos.
44 44 80 mm.dia (Table-17) BI01010001010000000000000515BI0100001156 9 Nos.
45 45 Wooden Sleeper 6" x 4" x 5' Long BI01010001010000000000000515BI0100001157 4 Nos.
46 46 100 mm.dia Foot Valve Lather Washer BI01010001010000000000000515BI0100001158 2 Nos.
47 47 M.S. Accessories: -150 mm.dia Sluice Valve BI01010001010000000000000515BI0100001159 3 Nos.
48 48 100 mm.dia Sluice Valve BI01010001010000000000000515BI0100001160 2 Nos.
49 49 150 mm.dia Alfa Alfa Valve BI01010001010000000000000515BI0100001161 13 Nos.
50 50 150 mm.dia 900 Bend BI01010001010000000000000515BI0100001162 4 Nos.
51 51 100 mm.dia 900 (with priming) Bend BI01010001010000000000000515BI0100001163 2 Nos.
52 52 100 mm.dia Swing type Foot Valve flanged end BI01010001010000000000000515BI0100001164 2 Nos.
53 53 100 mm.dia MS hose clamp with long nut & bolt BI01010001010000000000000515BI0100001165 22 Nos.
54 54 100 mm.dia MS Tail Piece One end Flanged other end grooved. BI01010001010000000000000515BI0100001166 10 Nos.
55 55 MS Set for quadruped (For Midi RLI Scheme) BI01010001010000000000000515BI0100001167 1 Set
56 56 Nuts & Bolts :- 20 mm x 80 mm BI01010001010000000000000515BI0100001168 185 Kg.
57 57 20 mm x 100 mm BI01010001010000000000000515BI0100001169 68 Kg.
58 58 16 mm x 80 mm BI01010001010000000000000515BI0100001170 72 Kg.
59 59 16 mm x 65 mm BI01010001010000000000000515BI0100001171 40 Kg.
60 60 16 mm x 50 mm BI01010001010000000000000515BI0100001172 40 Kg.
61 61 Foundation Bolt :- For Distrubution Chamber (20 mm.dia x 375 mm.long) (44 Nos.) BI01010001010000000000000515BI0100001173 30 Kg.
62 62 For Motor driven Pump Sets (8 Nos.) BI01010001010000000000000515BI0100001174 8 Kg.
63 63 Compresed Asbestos fibre jointing for Quadruped Set (for raised surface of Flange as per IS-6392/71) 500 mm.dia (Table-5) BI01010001010000000000000515BI0100001175 8 Nos.
64 64 Supply of Electromotor Pumping set with a suitable centrifugal water pump having capacity 100cub-meter/hr. discharge at 24m.head (section delivety 100mm x 100mm.dia).Motor shall be designed for 415Volt.(+-6%)3 phase 50 CPS.AC supply 1450 RPM.The motor shall be TEFC as per IS 325.The pump shall be horizontal single stage split casting as per IS 6595/IS 5120 coupled with motor and shall be according designed. BI01010001010000000000000515BI0100001176 2 Set
65 65 Supply of 200Amp. Min Switch Complete for 20 HP Motors BI01010001010000000000000515BI0100001177 1 No.
66 66 Supply of 63 Amp Main Switch BI01010001010000000000000515BI0100001178 2 Nos.
67 67 Supply of 16 Amp Main Switch BI01010001010000000000000515BI0100001179 1 No.
68 68 Supply of Oil Immersed Starter for 20 HP Motor BI01010001010000000000000515BI0100001180 2 Nos.
69 69 Supply of 4” Volt Meter (0-500V)- 2 Nos. & 4” Ammeter (0-100A)- 2 Nos. BI01010001010000000000000515BI0100001181 1 Set
70 70 Supply of Capacitor (6 KVA) BI01010001010000000000000515BI0100001182 2 Nos.
71 71 Supply of Brass bar BI01010001010000000000000515BI0100001183 1 No.
72 72 Supply of wooden pannel board of size 1.5m X 1m X 0.025m with 6 Nos. M.S. clamp for Pump House wall mounting BI01010001010000000000000515BI0100001184 1 No.
73 73 Supply of 16 mm dia 3.5 Core 1100V grade PVC Copper conducter/wire BI01010001010000000000000515BI0100001185 12 M
74 74 Supply of 10 mm dia 3 Core 1100V grade PVC Copper conducter/wire BI01010001010000000000000515BI0100001186 40 M
75 75 Supply of 6 mm dia single Core 1100V grade PVC Copper conducter/wire BI01010001010000000000000515BI0100001187 40 M
76 76 Supply of 1.5 mm dia single Core 1100V grade PVC Copper conducter/wire BI01010001010000000000000515BI0100001188 80 M
77 77 Supply of Sprinkler Kit with Electric Pump Set (single phase) discharging 5.22 cubic mtr./hour at 30 mtr. Total head including accessories Kirloskar make. BI01010001010000000000000515BI0100001189 1 Set
78 78 PVC 1 no. table & 4 nos. Chair BI01010001010000000000000515BI0100001190 1 Set
79 79 Tools kit comprising Slide wrench set 12" long, Ring wrench set, Side spanner set, Screw Driver 1' long, Hammer 500 Gram, Electrical Tester, Combind Pliers, Funnel 8" etc. BI01010001010000000000000515BI0100001191 2 Set
80 80 LAYING:- Supplying, fitting and fixing including transportation of sign board for indentifing the exact location of RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm x 600 mm and fitted and fixed on 50 mm GI pipe/35mm Angle of IS 1239/90 (part-1) including cutting , welding and writting of both sides of Sing board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include one materials and labour complete as per drawing and direction of EIC. BI01010001010000000000000515BI0100001192 1 No.
81 81 Suppling 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house. For W.T.A. BI01010001010000000000000515BI0100001193 1 No.
82 82 Earthwork in excavation of foundation or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone) including removing, spreading or stacking the spoils, as directed and including trimming the sides of trenches, leveling, dressing and ramming the bottoms, bailing or pumping out of water etc. as required complete. Depth of excavation not exceeding 1.5 metre (not required shoring) . For foundation blocks of Quadruped BI01010001010000000000000515BI0100001194 4.92 m3
83 83 ii) For Spout Chamber BI01010001010000000000000515BI0100001195 20.22 m3
84 84 iii) For Pipe line trenches BI01010001010000000000000515BI0100001196 1718 m3
85 85 iv) For Pillar BI01010001010000000000000515BI0100001197 2 m3
86 86 Gravels, morrum, Kankar, compact morrum/very much weathered rook/sticky soil mixed with morrum of ghoothing etc. BI01010001010000000000000515BI0100001198 100 m3
87 87 Soft weathers Rock or Soft laterite. BI01010001010000000000000515BI0100001199 10 m3
88 88 Local Sand filling in foundation or plinth in layers not exceeding 15 cm. as directed and consolidating the same by through saturation with water and ramming complete, including the cost of supply of sand.For foundation blocks of Quadruped BI01010001010000000000000515BI0100001200 0.983 m3
89 89 ii) For Spout Chamber BI01010001010000000000000515BI0100001201 7.137 m3
90 90 iii) For Pipe line trenches BI01010001010000000000000515BI0100001202 50 m3
91 91 iv) For Pillar BI01010001010000000000000515BI0100001203 0.1 m3
92 92 Laying of UPVC pipes of different diameters within field trenches in curve/straight line using UPVC fittings, viz. Horizontal and Vertical Bends, Riser pipes, tee, Reducer etc. and making leak proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge. i) 200 mm.dia Class-I BI01010001010000000000000515BI0100001204 1200 Meter
93 93 ii) 140 mm.dia Class-I BI01010001010000000000000515BI0100001205 1998 Meter
94 94 Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. i) For foundation blocks of Quadruped BI01010001010000000000000515BI0100001206 6.559 m2
95 95 ii) For Spout Chamber BI01010001010000000000000515BI0100001207 47.723 m2
96 96 iii) For Pillar BI01010001010000000000000515BI0100001208 1 m2
97 97 Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or striking out after completion of works (upto roof of ground floor) 25 mm. to 30.7 mm.thick wooden shuttering. i) For foundation blocks of Quadruped BI01010001010000000000000515BI0100001209 5.6 m2
98 98 ii) For Spout Chamber BI01010001010000000000000515BI0100001210 14.625 m2
99 99 iii) For Pillar BI01010001010000000000000515BI0100001211 1 m2
100 100 Cement Concrete (1:3:6) with graded stone ballast or local gravel 40mm.down, excluding shuttering. i) For foundation blocks of Quadruped BI01010001010000000000000515BI0100001212 0.895 m3
101 101 ii) For drop wall of Spout Chamber BI01010001010000000000000515BI0100001213 0.741 m3
102 102 iii) For Pillar BI01010001010000000000000515BI0100001214 0.075 m3
103 103 Re-inforcement for reinforced concrete work in all sorts of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening of bend bars excluding coil bars and removal of loose rust (if necessary) cutting to requisite length, hooking, bending to correct shape, placing in proper position and binding with 1.626mm. (16SWG) black annealed wire at every intersection complete as per drawing and direction including cost of wire upto 1st floor level (For Tor Steel) i) For WTA BI01010001010000000000000515BI0100001215 0.9 Qtl.
104 104 Cement Concrete (1:2:4) in foundation, floor and all sorts of RCC works with approved graded stone chips (20mm.size) excluding shuttering and re- inforcement in ground floor. i) For foundation blocks of Quadruped BI01010001010000000000000515BI0100001216 2 m3
105 105 ii) For Spout Chamber BI01010001010000000000000515BI0100001217 3.406 m3
106 106 Brick work in cement mortar (1:6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete.i) For W.T.A. BI01010001010000000000000515BI0100001218 1.2 m3
107 107 i) For Spout Chamber BI01010001010000000000000515BI0100001219 9 m3
108 108 iii) For Pillar BI01010001010000000000000515BI0100001220 0.75 m3
109 109 12.5 cm.thick 1st class brick work in cement mortar (1:4) in ground floor including scaffolding racking out joints etc. complete.i) For WTA BI01010001010000000000000515BI0100001221 11.4 m2
110 110 Labour charges for fitting, fixing of M.S. pipe (to be supplied Deptt.) including transportation of the same jointing and making leak proof threaded/flanged joints at site by using socket /rubber insertion, nuts and bolts etc. maintaining proper alignment and level all complete as per direction of Engineer-in-Charge. 150 mm.dia BI01010001010000000000000515BI0100001222 72 Metre
111 111 100 mm.dia BI01010001010000000000000515BI0100001223 24 Metre
112 112 Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for 1st chamber and 2nd chamber of Midi RLI Scheme. (Rate inclusive of transportation from departmental store to work site). BI01010001010000000000000515BI0100001224 1 Set
113 113 Labour Charge for fitting, fixing 150mm x 200mm. dia MS expander with 200 mm.dia UPVC pipe with the help of FTP (flanged Tail Piece) by joining flanged end of tail piece and expander with rubber insertion, nuts and bolts and PVC end of tail piece with 200 mm.dia UPVC pipe with coupler, all complete. BI01010001010000000000000515BI0100001225 6 Nos.
114 114 Labour charges for fitting, fixing 150 mm.dia Alfa Alfa Valve with 160 mm.dia (class-II) UPVC Riser pipe with the help of flange P.V.C. tailpiece by joining the P.V.C. End of Tail- piece and Riser pipe with coupler and flanged end of Tailpiece and Alfa Alfa valve with rubber insertion, Nuts and bolts etc. complete. (140 X 160mm Reducer & 200 x 160mm Reducer is to be fitted as per requirement) BI01010001010000000000000515BI0100001226 13 Nos.
115 115 Transportation of Diesel Engine pumping set / \nElectro-Motor pumping set for Midi R.L.I. of any make/brand with necessary fixtures viz. M.S. bend, M.S. Pipes, Rubber Hose Pipe, Manifold, Surge tank, foot valve, non-return valve, tail piece, hose clamp, sluice valve, priming chamber etc. over Pucca/Kancha road from Store to worksite including loading at the lifting point and unloading at the delivery point. (a) Carriage by Road (i) Distance upto 50 km. BI01010001010000000000000515BI0100001227 2 Set
116 116 (ii) Distance beyond 50 KM for such additional 25 KM or part thereof. BI01010001010000000000000515BI0100001228 2 Set
117 117 Installation of Diesel Engine/Electro Motor Pumping set of any make/brand and for RLI scheme on pump foundation over SAL sleeper (to be supplied departmentally) by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 900 MS priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-Charge. (Pump set and all accessories will be supplied departmentally.) For Midi R.L.I. Scheme BI01010001010000000000000515BI0100001229 2 Set
118 118 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners, as directed and racking out joints or roughening of concrete surface including throating, nosing and drip course as necessary at ground floor. a)with 1:6 cement mortar & 20 mm.thick i) For Spout Chamber BI01010001010000000000000515BI0100001230 27.4 m2
119 119 ii) For Pillar BI01010001010000000000000515BI0100001231 7.864 m2
120 120 b)with 1:6 cement mortar & 15 mm.thick i) For WTA BI01010001010000000000000515BI0100001232 10.44 m2
121 121 ii) For Spout Chamber BI01010001010000000000000515BI0100001233 132.24 m2
122 122 Neat cement punning about 1.5mm.thick in wall dado, floor, drain, door and window sill etc. complete. i) For WTA BI01010001010000000000000515BI0100001234 18.3 m2
123 123 ii) For Spout Chamber BI01010001010000000000000515BI0100001235 140.1 m2
124 124 Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 15cm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation.i)For Pipe Trench, Spout chamber & Quadruped etc. BI01010001010000000000000515BI0100001236 1698 m3
125 125 Two coats over one coat of primer Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary, over steel surface.For WTA BI01010001010000000000000515BI0100001237 25 m2
126 126 Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Deasel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in-Charge. (As it is electrified scheme so testing can be done with Electro Motor Pumping set & the departmental electric line) BI01010001010000000000000515BI0100001238 1 L.S.
127 127 PUMP HOUSE :-Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm BI01010001010000000000000515BI0100001239 17.71
128 128 Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150 mm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation. BI01010001010000000000000515BI0100001240 7.93
129 129 Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. BI01010001010000000000000515BI0100001241 7.75 m3
130 130 Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. BI01010001010000000000000515BI0100001242 43.07
131 131 Cement concrete (1:3:6) with graded stone ballast or local gravel 40 mm. down, excluding shuttering in ground floor. BI01010001010000000000000515BI0100001243 1.8
132 132 Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding Brick work with Ist class brick in cement mortar (1 : 6). (a) In foundation and Plinth BI01010001010000000000000515BI0100001244 8.76
133 133 (b) In superstructure , ground floor BI01010001010000000000000515BI0100001245 12.44
134 134 12.5 cm. thick 1st class brickwork in cement mortar (1 : 4) in ground floor including, scaffolding, racking out joints etc. complete. BI01010001010000000000000515BI0100001246 1.19
135 135 25 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over\ntwo coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid\nseperately) for underground water retaining structures. [water proofing as per item no 60 and non toxic paint as per Item No. 59 (b) of Section 'C' ] BI01010001010000000000000515BI0100001247 3.54
136 136 Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(d) With local hard blackstone variety chips.d) With local hard backstone variety chips (crusher broken) BI01010001010000000000000515BI0100001248 7.49
137 137 Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30.0 mm. thick wooden shuttering. BI01010001010000000000000515BI0100001249 41.65
138 138 Reinforcement for reinforced concrete work in all sorts of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening of bend bars excluding coil bars and removal of loose rust (if necessary) cutting to requisite length, hooking, bending to correct shape, placing in proper position and binding with 1.626 mm (16 SWG) black annealed wire at every inter section complete as per drawing and direction including cost of wire upto 1st floor level. ( For Tor steel). BI01010001010000000000000515BI0100001250 3.66 Qtl.
139 139 Plaster (to wall, floor ceiling etc) with sand and cement mortar including rounding off or chamfering corners, as directed and racking out joints or roughening of concrete surface including throating, nosing and drip course , scaffolding/ staging as necessary at ground floor. (Excluding cost of chipping over concrete surface) (a) with (1:6) cement mortar , 20 mm. thick plaster. BI01010001010000000000000515BI0100001251 31.65
140 140 (b) with (1:6) cement mortar , 15 mm. thick plaster. BI01010001010000000000000515BI0100001252 110.46 m2
141 141 (c) with (1:4) cement mortar , 10 mm. thick plaster. BI01010001010000000000000515BI0100001253 34.21 m2
142 142 Grey artificial stone in floor, dado,staircase etc. with cement concrete 1:2:4 with stone chips laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion that 1:2 including smooth finishing and rounding off corners including raking of joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour . In ground floor. 3.00 mm.thick topping ( high polishing , grinding on these item is not permitted with ordinary cement). Using grey cement (ii) 25 mm thick. BI01010001010000000000000515BI0100001254 11.77
143 143 Neat cement punning about 1.5 mm. thick in wall dado,floor, drain, door and window sill etc. complete. BI01010001010000000000000515BI0100001255 46.72
144 144 M.S. gate of Jail type as per approved design made of strong M.S. frame work intermediate stiffeners and round / square bars or angles. M.S. Sheet (not less than 14 gauge) gussets, cleats etc including necessary riveting, bolting, welding, locking and hanging etc.complete. BI01010001010000000000000515BI0100001256 4.6 sqm
145 145 Supplying, fitting & fixing windows and vatilator with or without intigrated grills confirming to IS 1038-1975 and manufacturered from roll steel section conforming to IS 7452-1974 with non fixtion projecting type, box type hings glazing clips, lugs locking bracket, handle plate etc., including hoisting in position strenghtening if required, fixing lugs in cement concretre (1:2:4) with stone chips 20 mm down cutting hole and manding good damages to match with exting surface complete in all respect excluding glazing in ground floor.\nFlash butt welded windows and vantilators\n(b) Openable steel windows as per IS sizes with side hung shutters on horizental glazing bars with/without fix type vantilator (the extra rate admissible for openble portion only) BI01010001010000000000000515BI0100001257 3.24
146 146 MS integrated grill as per approved design integrated with steel window or vantilators joints contiously welded with MS flats and bars. BI01010001010000000000000515BI0100001258 48.6 Kg
147 147 Supplying 1.5 mm thick MS sheet fitted and fixed on one or both faces of MS/WI gate etc with point welding at not more than 150 mm apart complete in all repect as per design including cost of all labour and materials. BI01010001010000000000000515BI0100001259 3.24 sqm
148 148 Supplying ,fitting, fixing UPVC Pipes A type and fittings conforming to IS: 13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cuting treches in any soil through masonry concrete structures etc. if necessary and manding a good damage including jointing materials (Spun yarn, valamoid/Bitumen/M-seal etc.) complete.A) UPVC Pipes: ii) 110 mm.dia BI01010001010000000000000515BI0100001260 3 Mtr.
149 149 Supplying fitting approved type ventilator in position after cutting holes in walls, setting in cement mortar, mending damages to wall and plaster two coats of paint of approved brand sand shade. Payment of mending two damages of wall & plaster and painting to be mase seperately.b) RCC ventilator of 20 mm thick upto 0.10 sqm area BI01010001010000000000000515BI0100001261 6 Each
150 150 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc including using of approved putty etc on the surface, if necessary. (b) On steel surface (Normal gloss).Two coats (with any shade except white). BI01010001010000000000000515BI0100001262 20.93
151 151 White washing including cleaning and smoothening surface thoroughly. (c) Three coats (on new work only) BI01010001010000000000000515BI0100001263 53.52
152 152 Colour washing with "ELLA" with a coat of white wash priming including cleaning and smoothening surface thoroughly(ii) External surface( Ground floor) (b) Two coats BI01010001010000000000000515BI0100001264 87.07
153 153 Rough dressed timber planks fitted and fixed with nut bolts excluding framework complete: In Ground floor iv)above 50 mm thick planks (b) Sal local BI01010001010000000000000515BI0100001265 0.05 cum
154 154 ELECTRIC WIRING :- Fitting of wooden pannel board of size 1.5m X 1m X 0.025m with M.S. clamp on the wall of pump house and made necessary arrangment for fitting fixing the following elctrical equipment including 2 coat of pantigof app.quality as per direction of E.I.C. (Deptt. supply) BI01010001010000000000000515BI0100001266 1 LS
155 155 Fixing only Iron Clad/Sheet Steel TP/TPN switch fuse units with H.R.C. fuses on angle iron frame on wall (a) 200 Amps. (Deptt. supply) (PWD /Page-C-1, Item No.-2) BI01010001010000000000000515BI0100001267 1 Each
156 156 Fixing only Iron Clad/Sheet Steel TP/TPN switch fuse units with H.R.C. fuses on angle iron frame on wall (Deptt. supply) (a) 63 Amps. (PWD /Page-C-1, Item No.-3) BI01010001010000000000000515BI0100001268 2 Each
157 157 Fixing only 500 V Iron Clad/MS sheet metal busbar chamber on angle iron frame on wall (Deptt. supply)(PWD /Page-C-2, Item No.-8) (4 bars 200 Amps) BI01010001010000000000000515BI0100001269 1 Each
158 158 Fixing Voltmeter/energy meter with necy., screws & other fixing materials & making holes where necy. Incl. making connections(Deptt. supply) (PWD /Page-C-2, Item No.-13) BI01010001010000000000000515BI0100001270 1 Each
159 159 Wiring with supply 16 mm.dia 4 core 1100 volt grade PVC copper wire in the PVC flexible from 200 Amps. Main switch to bus bar chamber. (6 mtr. Long wire supplied by Deptt.) BI01010001010000000000000515BI0100001271 1 LS
160 160 3 phase selected switch supply and fitting, fixing and making connection. BI01010001010000000000000515BI0100001272 1 Unit
161 161 Supply & fitting, fixing etc. complete of power indicator lamp. BI01010001010000000000000515BI0100001273 1 Set
162 162 Supplying & fixing EL Danger Board on wall\na) 15cm x 10cm (6" x 4") (PWD /Page-D-13, Item No.-21(a)) BI01010001010000000000000515BI0100001274 1 Each
163 163 Supplying & fitting, fixing of 200 Amp Cut Out. BI01010001010000000000000515BI0100001275 6 Each
164 164 Supply and fixing and Soldering Copper Socket flat type as required BI01010001010000000000000515BI0100001276 1 LS
165 165 Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall.\n(b) Star-Delta starter / Oil immersed starter 20 HP for motor (upto 5 HP for lower ratings and above 5 HP upto 15 HP for higher rating)\n (Deptt. Supply) (PWD /Page-C-2, Item No.-7(b)) BI01010001010000000000000515BI0100001277 2 Each
166 166 Drawing inter connection between starter to motor by 10 sq.mm. P.V.C. insulated copper conductor (any approved make), 3 core 2 nos. 1100 volt grade P.V.C. conduit fitted with necessary bend, elbows, inspection pit etc. with brass coupling and cable protector by fixing with saddle on the wall and partly under the ground by cutting and mending good the floor where as one ft. apart the motor to be flexible conduit P.V.C. by metal and double earthing continuously by 10 SWG GI Wire. (20 mtr. long wire supplied by Deptt.) BI01010001010000000000000515BI0100001278 1 LS
167 167 Distn. Wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (approved make) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (2 mm thick) flused in wall incl. mending good damages to original finish (PWD /Page-E-10, Item No.-3(a)(iii))2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC Avegage run 8 mtr. BI01010001010000000000000515BI0100001279 3 Point
168 168 Fixing only iron Clad/Sheet Steel Main Switchs/Isolators on Iron Legs/Flat Iron Frame/Angle Iron Frame on wall (Deptt. supply) (PWD /Page-C-1, Item No.-1)16 Amps On Iron legs BI01010001010000000000000515BI0100001280 1 Each
169 169 Excavation of soil for installation of Earth Elctrode and filling & ramming. (It-1(a), Page-G-1)\n(a) For soft soil BI01010001010000000000000515BI0100001281 2.75 Cu mtr
170 170 Earthing with 50 mm dia GI Pipe 3.64 mm thick x 3.04 Mts. Long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long ), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mts. below the ground level & restoring surface duly rammed as below. (PWD /Page-G-1, Item No.-2(a)For Soft Soil By ISI-Medium GI Pipe BI01010001010000000000000515BI0100001282 2 Item
171 171 (a) Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulatiors etc. as required (PWD /Page-G-2, Item No.-4(a)) BI01010001010000000000000515BI0100001283 2 Each
172 172 Supplying & drawing inter connection between Bus bar chamber to 63 Amps main switch, Main switch to 6 KVA Capacitor & 6 KVA capacitor to 20 HP Star delta Starter / Oil Immersed starter E.T.C by 10 sq.mm. P.V.C. insulated copper conductor(any approved make), 3 Core, 1100 Volt grade P.V.C. conduit fitted with necessary bend, elbows, inspection pit etc. with brass coupling and calbe protector and earthing by 10 SWG GI Wire as per I.E.C. regulation. (15 mtr. long wire supplied by Deptt.) BI01010001010000000000000515BI0100001284 1 LS
173 173 Supply & Drawing connection by 6 sq.mm. single core copper wire (any approved make) from D.P.I.C. Switch to Meter bord of W.B.S.E.D & CL with 3/4" flexible conduit including drawing earth wire of 18 SWG Copper wire. (8 mtr. long wire supplied by Deptt.) BI01010001010000000000000515BI0100001285 1 LS
174 174 Fitting, fixing and interconnecting the 6 KVA Capacitor JAVIC/KELTRON from bus bar by loop wiring with 660 Volt grade BI01010001010000000000000515BI0100001286 2 LS
175 175 (b) Supply & Fitting for Lamp & Shade (PWD /Page-C-3, Item No.-14(b)) BI01010001010000000000000515BI0100001287 3 Set
176 176 Supply (Fitting & Fixing) shack proof pad 6' x 3' x 1/2" with ISI make. BI01010001010000000000000515BI0100001288 1 L.S
177 177 Submission of Test Form in the prescribed form obtaining from W.B.S.E.B. after mager test by a licenced Electrical supervisor and contractor having competency certificate in Part-I, II, XI, IV, VI-A, VI-B, VII-A. BI01010001010000000000000515BI0100001289 1 L.S
178 178 Add 4% Extra for WATER TRANSMISSION ARRANGEMENT ON (Sl No.80-126), Except Earth Work In Excavation &Filling (Sl.No-82,83,84,85&124) BI01010001010000000000000515BI0100001290 1 L.S
179 179 Add 4% Extra for PUMP HOUSE ON (Sl No.127-153) Except Earth Work In Excavation &Filling (Sl.No-127&128) BI01010001010000000000000515BI0100001291 1 L.S.
180 180 Add GST @12% ON (Sl No.80-177) BI01010001010000000000000515BI0100001292 1 L.S.
181 181 Add labour welfare cess @ 1% ON (Sl No.80-177)total with GST BI01010001010000000000000515BI0100001293 1 L.S.