Supply Of Electrical Items For 2X500 Mw, Dtps, Anpara, Anpara-Uttar Pradesh

Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published Supply Of Electrical Items For 2X500 Mw, Dtps, Anpara. Submission Date for this Tender is 03-02-2021. Bolts Tenders in Anpara Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26656175
Supply Of Electrical Items For 2X500 Mw, Dtps, Anpara
Open Tender
Indian
Uttar Pradesh
Anpara
03-02-2021

Tender Details

Supply Of Electrical Items For 2X500 Mw, Dtps, Anpara-1 Moulded case circuit breaker (MCCB): 200 Amp, TPN (3 Pole+Neutral), Rated Current Ie=200 Amp, Rated Operating Voltage Ue= 690 Volt with standard short circuit breaking capacity Icu= 40-50 kA at 50 Hz, 415V, Comply with IEC 60947-1 & 2 and EN 60947-1 & 2, having overload and short circuit release. Make- Havells 2 Miniature circuit breaker (MCB)- Rated voltage Ue: 240/415V, 50 Hz, No. of poles: 3P+N, Rated short circuit breaking capacity: 10kA, Protection class: IP-20, Mounting: Clip on DIN rail, Characteristic curve: C, Complying standard: EN 60898-1 case & cover: Moulded, flame retardant thermoplastic material Rating 20Amp Make- Havells 3 Miniature circuit breaker (MCB)- Rated voltage Ue: 240/415V, 50 Hz, No. of poles: 3P+N, Rated short circuit breaking capacity: 10kA, Protection class: IP-20, Mounting: Clip on DIN rail, Characteristic curve: C, Complying standard: EN 60898-1 case & cover: Moulded, flame retardant thermoplastic material Rating 32Amp Make- Havells 4 Miniature circuit breaker (MCB)- Rated voltage Ue: 240/415V, 50 Hz, No. of poles: 3P+N, Rated short circuit breaking capacity: 10kA, Protection class: IP-20, Mounting: Clip on DIN rail, Characteristic curve: C, Complying standard: EN 60898-1 case & cover: Moulded, flame retardant thermoplastic material Rating 63Amp Make- Havells 5 TPN Switch fuse unit, 250 Amp. In sheet steel enclosure, Operating voltage 415V, 50Hz Make- Siemens/ nL&T n 6 Instrument Selector Switch, Rotary Switch (ASS), IEC/EN-60947-5, IS-13947-5, Ui-550V, 10A, Current in each phase with off 4 position 90 indicating plate size 65x65mm sq (Ammeter selector Switch), KAYCEE make 7 200 Amp, TP Switch fuse unit with 03 Nos HRC Fuse link, 125Amp, Ref-DIN (CSSDF200D3), Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, C&S Make 8 200 Amp, TPN Switch fuse unit with 03 Nos HRC Fuse link, 125Amp, Ref-DIN (CSSDF200D3N), Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, C&S Make 9 63 Amp, TPN Switch fuse unit with 03 Nos HRC Fuse link, 63Amp, Ref-DIN (CSSDF200DF63D3N), Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3 for LDB, C&S Make 10 125/80 Amp, TP Switch fuse unit with 03 Nos HRC Fuse link, 125Amp, Ref-DIN (CSSDF125D3), Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, C&S Make 11 125/80 Amp, TPN Switch fuse unit with 03 Nos HRC Fuse link, 125Amp, Ref-DIN (CSSDF125D3N), Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, nC&S Make n 12 Instrument Selector Switch, Rotary Switch (VSS), IEC/EN-60947-5, IS-13947-5, Ui-550V, 10 voltage between phase with off 4Position 90 indicating plate size 65x65mm.sq. (Volt meter selector switch), KAYCEE Make 13 200 Amp. TPN DC Switch, Ref- DIN (CSSDF200D2) Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, 14 32 Amp. TPN DC Switch, Ref- DIN (CSSDF32D3N) Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, C&S Make 15 63 Amp. TPN incoming ON/OFF Switch Fuse Unit Ref-DIN (CSSDF200DF63D3N) 415V, 50Hz, Confirms to IS/IEC 60947-3/IS 13947 for lighting panel, C&S Make 16 Auto manual Switch 3 pole, two way with off IEC/EN-60947-5, IS-13947-5, Ui-550V, 10A, 4-Position 90, KAYCEE make 17 32 Amp. DP incoming ON/OFF Switch (Rotary type) DIN (CSSDF32D2) Range 32A-800A, 415V, 50Hz, Confirms to IS/IEC 60947-3/IS 13947-3 C&S Make 18 32 Amp. DC Connector, DC Coil, Confirms to IS/IEC 60947-3/IS 13947-4-1 & IEC-60947-4-1, Ref-TP 1-D32 101, C&S Make 19 200 Amp. TP DC Contactor (220V DC), Conforms to IS/IEC 60947-3/IS13947-4-1 & IEC-60947-4-1, Ref-LC 1-FDP-200A, C&S Make 20 63 Amp. Power Contactor, 3Pole, AC, AC Coil, Size- Frame3, AC1 Duty A-80, AC3 415V Long life (KW-37, HP-50, A-63) TCLCI-D633: AC60, C&S Make 21 Control Fuse- 10Amp., IEC Size-F1, Ref. CNS (off set) Clip in type, Conforms to IEC-60269-2/IS13703-2, High Breaking Capacity-80kA, C&S make 22 Control Fuse- 4Amp., IEC Size-F1, Ref. CNS (off set) Clip in type, Conforms to IEC-60269-2/IS13703-2, High Breaking Capacity-80kA, C&S make 23 Control Fuse-20Amp., IEC Size-F1, Ref. CNS (off set) Clip in type, Conforms to IEC-60269-2/IS13703-2, High Breaking Capacity-80kA, C&S make 24 Integrated LED Pilot lamp 22.5mm. Red Indicating lamp 240V, LED Type (RCB7-IVL74), Conforms to IS13947-5, C&S make 25 Integrated LED Pilot lamp 22.5mm. Green Indicating lamp 240V, LED Type (RCB7-IVL73), Conforms to IS13947-5, C&S make 26 3Cx2.5 sq.mm., 1.1KV, Unarmoured Control Cable, Multistrand Copper Conductor, XLPE Insulated, Inner Sheath PVC Type ST-2, Outer SheathFRLS type, IS-7098 (Part-I)-1988, Minimum thickness of PVC innersheath: 0.30mm, nominal thickness of PVC outersheath: 1.80, nominal thickness of XLPE insulation: 0.7mm., Maximum conductor DC resistance at 20C: 7.41 Ohm/Km. approximate AC resistance at 90 C: 9.48 Ohm/Km. approximate Capacitance: 0.10 mfd/Km. Current rating (Direct in ground): 34 Amp. Current rating (in air): 30 Amp., short circuit current rating for 1 second duration: 0.458 kA. 27 Cable, Voltage grade 1.1 KV, Armoured, stranded aluminium conductor XLIPE Insulation, Inner Sheath PVC& PVC Outer Sheath FRLS type, IS-7098 (Part-I)-1988, 3.5Cx50 sq.mm Al. Conductor (Thickness of insulation= 1.0mm., thickness of PVC innersheath: 0.30mm, thickness of PVC outersheath: 1.56mm, Approximate Outer dia.= 29.5mm., GI round wire thickness= 1.6 mm., DC resistance= 0.641 Ohm/km, Max. Conductor temperature= 90C, Capacitance= 0.50 mfd/km., current= 133 Amp., Short circuit current= 4.7 kAmp. 28 DC Light Lighting Fixture BJDB-100 (Type-TB22), 100W, GLS ES, 240V, 0.42 Amp. 29 DC Ligh Lighting Fixture BJDR-100 (Type-TX04), 100W, SPOT LUX, 240V, 0.43 Amp. 30 DC Ligh Lighting Fixture BJVW-200/VE (Type-TW41) 31 HPSV Lamp 150 Watt (E), Nominal Lumen=15000 32 HPSV Lamp 70 Watt (E), Nominal Lumen=5800 33 Complete Extension Wooden Board, Size- 7”X4” Having 15 Amp. Switch: 1 No., 15 Amp. 5 Pin Socket: 1 No., Anchor Make mounted on white mica sheet. 34 Complete Extension Wooden Board, Size- 8”X10” Having 5 Amp. Switch: 2 No., 5 Amp. 3 Pin Socket: 2 No., Anchor Make mounted on white mica sheet. 35 15 Amp. Switch, Anchor Make 36 5 Amp. Switch, Anchor Make 37 PVC Casing Capping, Size- 1.25” of length 6 ft. 38 Kanti for PVC Casing capping (50 No. in 1 Pkt.) 39 CRC, 2-26 (500 ml.) 40 Alnox (Electrical joint compound) tube 41 Raychem- RPG Make, Heat Shrink Outdoor termination for straight through jointing kit suitable for 6.6 KV, XLPE, Aluminium conductor (Unearth) n1CX300 Sq.mm. n 42 Raychem- RPG Make, Heat Shrink Outdoor termination for straight through jointing kit suitable for 6.6 KV, XLPE, Aluminium conductor (Unearth) n3CX185 Sq.mm. n 43 High Voltage Insulating tape of 25 KV/mm. Dimension: 50mmX0.76X9.1m for XLPE Power Cable, Code: 2117 44 Aluminium Tube Terminals Lugs, For LT (1.1KV), Power Cables For 25 Sq.mm., E-bolt size: M8, Code: ALS-521 45 Aluminium Tube Terminals Lugs, For LT (1.1KV), Power Cables For 25 Sq.mm., E-bolt size: M10, Code: ALS-519 46 Aluminium Tube Terminals Lugs, For LT (1.1KV), Power Cables For 50 Sq.mm., E-bolt size: M8, Code: ALS-225 47 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 6 Sq.mm., E-bolt size: M5, Code: CUS-390 48 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 25 Sq.mm., E-bolt size: M8, Code: CUS-551 49 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 35 Sq.mm., E-bolt size: M10, Code: CUS-554 50 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 50 Sq.mm., E-bolt size: M10, Code: CUS-556 n 51 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 70 Sq.mm., E-bolt size: M13, Code: CUS-559 n 52 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 95 Sq.mm., E-bolt size: M13, Code: CUS-561 n 53 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 120 Sq.mm., E-bolt size: M12, Code: CUS-241 n 54 Copper Tube Heavy Duty In Line Connectors for LT/Controls Cables For 1.5 Sq.mm., Code: EH-453 n 55 Copper Tube Heavy Duty In Line Connectors for LT/Controls Cables For 2.5 Sq.mm., Code: EH-454 n

Key Value

Document Fees
INR 1180 /-
EMD
INR 15000.0 /-
Tender Value
INR 13.13 Lakhs /-

BOQ Items

Name of Work: < Supply of electrical items for 2x500 MW, DTPS, Anpara>
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Moulded case circuit breaker (MCCB): 200 Amp, TPN (3 Pole+Neutral), Rated Current Ie=200 Amp, Rated Operating Voltage Ue= 690 Volt with standard short circuit breaking capacity Icu= 40-50 kA at 50 Hz, 415V, Comply with IEC 60947-1 & 2 and EN 60947-1 & 2, having overload and short circuit release. Make- Havells item1 4 N0.
2 2 Miniature circuit breaker (MCB)- Rated voltage Ue: 240/415V, 50 Hz, No. of poles: 3P+N, Rated short circuit breaking capacity: 10kA, Protection class: IP-20, Mounting: Clip on DIN rail, Characteristic curve: C, Complying standard: EN 60898-1 case & cover: Moulded, flame retardant thermoplastic material Rating 20Amp Make- Havells item2 20 N0.
3 3 Miniature circuit breaker (MCB)- Rated voltage Ue: 240/415V, 50 Hz, No. of poles: 3P+N, Rated short circuit breaking capacity: 10kA, Protection class: IP-20, Mounting: Clip on DIN rail, Characteristic curve: C, Complying standard: EN 60898-1 case & cover: Moulded, flame retardant thermoplastic material Rating 32Amp Make- Havells item3 10 N0.
4 4 Miniature circuit breaker (MCB)- Rated voltage Ue: 240/415V, 50 Hz, No. of poles: 3P+N, Rated short circuit breaking capacity: 10kA, Protection class: IP-20, Mounting: Clip on DIN rail, Characteristic curve: C, Complying standard: EN 60898-1 case & cover: Moulded, flame retardant thermoplastic material Rating 63Amp Make- Havells item4 10 N0.
5 5 TPN Switch fuse unit, 250 Amp. In sheet steel enclosure, Operating voltage 415V, 50Hz Make- Siemens/\nL&T\n item5 3 N0.
6 6 Instrument Selector Switch, Rotary Switch (ASS), IEC/EN-60947-5, IS-13947-5, Ui-550V, 10A, Current in each phase with off 4 position 90 indicating plate size 65x65mm sq (Ammeter selector Switch), KAYCEE make item6 5 N0.
7 7 200 Amp, TP Switch fuse unit with 03 Nos HRC Fuse link, 125Amp, Ref-DIN (CSSDF200D3), Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, C&S Make item7 3 N0.
8 8 200 Amp, TPN Switch fuse unit with 03 Nos HRC Fuse link, 125Amp, Ref-DIN (CSSDF200D3N), Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, C&S Make item8 3 N0.
9 9 63 Amp, TPN Switch fuse unit with 03 Nos HRC Fuse link, 63Amp, Ref-DIN (CSSDF200DF63D3N), Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3 for LDB, C&S Make item9 8 N0.
10 10 125/80 Amp, TP Switch fuse unit with 03 Nos HRC Fuse link, 125Amp, Ref-DIN (CSSDF125D3), Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, C&S Make item10 2 N0.
11 11 125/80 Amp, TPN Switch fuse unit with 03 Nos HRC Fuse link, 125Amp, Ref-DIN (CSSDF125D3N), Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, \nC&S Make\n item11 2 N0.
12 12 Instrument Selector Switch, Rotary Switch (VSS), IEC/EN-60947-5, IS-13947-5, Ui-550V, 10 voltage between phase with off 4Position 90 indicating plate size 65x65mm.sq. (Volt meter selector switch), KAYCEE Make item12 5 N0.
13 13 200 Amp. TPN DC Switch, Ref- DIN (CSSDF200D2) Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, item13 3 N0.
14 14 32 Amp. TPN DC Switch, Ref- DIN (CSSDF32D3N) Range 32A-800A, 415V 50Hz, Conforms to IS/IEC 60947-3/IS13947-3, C&S Make item14 4 N0.
15 15 63 Amp. TPN incoming ON/OFF Switch Fuse Unit Ref-DIN (CSSDF200DF63D3N) 415V, 50Hz, Confirms to IS/IEC 60947-3/IS 13947 for lighting panel, C&S Make item15 20 N0.
16 16 Auto manual Switch 3 pole, two way with off IEC/EN-60947-5, IS-13947-5, Ui-550V, 10A, 4-Position 90, KAYCEE make item16 5 N0.
17 17 32 Amp. DP incoming ON/OFF Switch (Rotary type) DIN (CSSDF32D2) Range 32A-800A, 415V, 50Hz, Confirms to IS/IEC 60947-3/IS 13947-3 C&S Make item17 2 N0.
18 18 32 Amp. DC Connector, DC Coil, Confirms to IS/IEC 60947-3/IS 13947-4-1 & IEC-60947-4-1, Ref-TP 1-D32 101, C&S Make item18 2 N0.
19 19 200 Amp. TP DC Contactor (220V DC), Conforms to IS/IEC 60947-3/IS13947-4-1 & IEC-60947-4-1, Ref-LC 1-FDP-200A, C&S Make item19 2 N0.
20 20 63 Amp. Power Contactor, 3Pole, AC, AC Coil, Size- Frame3, AC1 Duty A-80, AC3 415V Long life (KW-37, HP-50, A-63) TCLCI-D633: AC60, C&S Make item20 10 N0.
21 21 Control Fuse- 10Amp., IEC Size-F1, Ref. CNS (off set) Clip in type, Conforms to IEC-60269-2/IS13703-2, High Breaking Capacity-80kA, C&S make item21 20 N0.
22 22 Control Fuse- 4Amp., IEC Size-F1, Ref. CNS (off set) Clip in type, Conforms to IEC-60269-2/IS13703-2, High Breaking Capacity-80kA, C&S make item22 20 N0.
23 23 Control Fuse-20Amp., IEC Size-F1, Ref. CNS (off set) Clip in type, Conforms to IEC-60269-2/IS13703-2, High Breaking Capacity-80kA, C&S make item23 20 N0.
24 24 Integrated LED Pilot lamp 22.5mm. Red Indicating lamp 240V, LED Type (RCB7-IVL74), Conforms to IS13947-5, C&S make item24 25 N0.
25 25 Integrated LED Pilot lamp 22.5mm. Green Indicating lamp 240V, LED Type (RCB7-IVL73), Conforms to IS13947-5, C&S make item25 25 N0.
26 26 3Cx2.5 sq.mm., 1.1KV, Unarmoured Control Cable, Multistrand Copper Conductor, XLPE Insulated, Inner Sheath PVC Type ST-2, Outer SheathFRLS type, IS-7098 (Part-I)-1988, Minimum thickness of PVC innersheath: 0.30mm, nominal thickness of PVC outersheath: 1.80, nominal thickness of XLPE insulation: 0.7mm., Maximum conductor DC resistance at 20C: 7.41 Ohm/Km. approximate AC resistance at 90 C: 9.48 Ohm/Km. approximate Capacitance: 0.10 mfd/Km. Current rating (Direct in ground): 34 Amp. Current rating (in air): 30 Amp., short circuit current rating for 1 second duration: 0.458 kA. item26 1000 Meter
27 27 Cable, Voltage grade 1.1 KV, Armoured, stranded aluminium conductor XLIPE Insulation, Inner Sheath PVC& PVC Outer Sheath FRLS type, IS-7098 (Part-I)-1988, 3.5Cx50 sq.mm Al. Conductor (Thickness of insulation= 1.0mm., thickness of PVC innersheath: 0.30mm, thickness of PVC outersheath: 1.56mm, Approximate Outer dia.= 29.5mm., GI round wire thickness= 1.6 mm., DC resistance= 0.641 Ohm/km, Max. Conductor temperature= 90C, Capacitance= 0.50 mfd/km., current= 133 Amp., Short circuit current= 4.7 kAmp. item27 500 Meter
28 28 DC Light Lighting Fixture BJDB-100 (Type-TB22), 100W, GLS ES, 240V, 0.42 Amp. item28 25 N0.
29 29 DC Ligh Lighting Fixture BJDR-100 (Type-TX04), 100W, SPOT LUX, 240V, 0.43 Amp. item29 25 N0.
30 30 DC Ligh Lighting Fixture BJVW-200/VE (Type-TW41) item30 25 N0.
31 31 HPSV Lamp 150 Watt (E), Nominal Lumen=15000 item31 40 N0.
32 32 HPSV Lamp 70 Watt (E), Nominal Lumen=5800 item32 60 N0.
33 33 Complete Extension Wooden Board, Size- 7”X4” Having 15 Amp. Switch: 1 No., 15 Amp. 5 Pin Socket: 1 No., Anchor Make mounted on white mica sheet. item33 10 N0.
34 34 Complete Extension Wooden Board, Size- 8”X10” Having 5 Amp. Switch: 2 No., 5 Amp. 3 Pin Socket: 2 No., Anchor Make mounted on white mica sheet. item34 10 N0.
35 35 15 Amp. Switch, Anchor Make item35 10 N0.
36 36 5 Amp. Switch, Anchor Make item36 50 N0.
37 37 PVC Casing Capping, Size- 1.25” of length 6 ft. item37 50 N0.
38 38 Kanti for PVC Casing capping (50 No. in 1 Pkt.) item38 10 N0.
39 39 CRC, 2-26 (500 ml.) item39 6 N0.
40 40 Alnox (Electrical joint compound) tube item40 6 N0.
41 41 Raychem- RPG Make, Heat Shrink Outdoor termination for straight through jointing kit suitable for 6.6 KV, XLPE, Aluminium conductor (Unearth)\n1CX300 Sq.mm.\n item41 1 N0.
42 42 Raychem- RPG Make, Heat Shrink Outdoor termination for straight through jointing kit suitable for 6.6 KV, XLPE, Aluminium conductor (Unearth)\n3CX185 Sq.mm.\n item42 1 N0.
43 43 High Voltage Insulating tape of 25 KV/mm. Dimension: 50mmX0.76X9.1m for XLPE Power Cable, Code: 2117 item43 10 Roll
44 44 Aluminium Tube Terminals Lugs, For LT (1.1KV), Power Cables For 25 Sq.mm., E-bolt size: M8, Code: ALS-521 item44 50 N0.
45 45 Aluminium Tube Terminals Lugs, For LT (1.1KV), Power Cables For 25 Sq.mm., E-bolt size: M10, Code: ALS-519 item45 25 N0.
46 46 Aluminium Tube Terminals Lugs, For LT (1.1KV), Power Cables For 50 Sq.mm., E-bolt size: M8, Code: ALS-225 item46 30 N0.
47 47 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 6 Sq.mm., E-bolt size: M5, Code: CUS-390 item47 50 N0.
48 48 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 25 Sq.mm., E-bolt size: M8, Code: CUS-551 item48 30 N0.
49 49 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 35 Sq.mm., E-bolt size: M10, Code: CUS-554 item49 30 N0.
50 50 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 50 Sq.mm., E-bolt size: M10, Code: CUS-556\n item50 30 N0.
51 51 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 70 Sq.mm., E-bolt size: M13, Code: CUS-559\n item51 30 N0.
52 52 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 95 Sq.mm., E-bolt size: M13, Code: CUS-561\n item52 30 N0.
53 53 Copper Tube Terminals Lugs, Heavy Duty For 1.1 KV, LT Power Cables For 120 Sq.mm., E-bolt size: M12, Code: CUS-241\n item53 30 N0.
54 54 Copper Tube Heavy Duty In Line Connectors for LT/Controls Cables For 1.5 Sq.mm., Code: EH-453\n item54 200 N0.
55 55 Copper Tube Heavy Duty In Line Connectors for LT/Controls Cables For 2.5 Sq.mm., Code: EH-454\n item55 500 N0.
Disclaimer :