Chandigarh Administration Engineering Department has published Renovation Of Ei And Switchgear In Sainik Guest House ( Community Centre For Ex . Service Man ) At Sec-21-D , Chandigarh . . Submission Date for this Tender is 27-01-2021. Electrification Work Tenders in Chandgarh Chandigarh. Bidders can get complete Tender details and download the document.
Name of Work: Renovation of EI and Switchgear in Sainik Guest house (Community Centre for Ex. Service man) at Sec-21-D, Chandigarh. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | DSR 1.8 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | |||
2 | 1.01 | Group C | NSR | 70 | nos. |
3 | 2 | DSR 1.29 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. | NSR1 | 15 | nos. |
4 | 3 | DSR 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. | NSR2 | 22 | nos. |
5 | 4 | DSR 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required | |||
6 | 4.01 | 20mm | NSR3 | 50 | mtr. |
7 | 4.02 | 25mm | NSR4 | 400 | mtr. |
8 | 5 | DSR 1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. | NSR5 | 25 | nos. |
9 | 6 | DSR 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. | NSR6 | 2 | nos. |
10 | 7 | DSR 1.22 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. | |||
11 | 7.01 | 200 mm X 150 mm X 60 mm deep | NSR7 | 8 | nos. |
12 | 8 | DSR 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||
13 | 8.01 | 3 x 1.5 sq. mm | NSR8 | 200 | mtr. |
14 | 8.02 | 3 x 2.5 sq. mm | NSR9 | 500 | mtr. |
15 | 8.03 | 3 x 4 sq.mm | NSR10 | 140 | mtr. |
16 | 9 | DSR 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | |||
17 | 9.01 | 4 way (4 + 12), Double door | NSR11 | 1 | nos. |
18 | 9.02 | 6 way (4 + 18), Double door | NSR12 | 1 | nos. |
19 | 10 | DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
20 | 10.01 | Single pole | NSR13 | 30 | nos. |
21 | 11 | DSR 2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
22 | 11.01 | 40 A | NSR14 | 2 | nos. |
23 | 12 | DSR 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. | NSR15 | 2 | nos. |
24 | 13 | DSR 5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | NSR16 | 15 | mtr. |
25 | 14 | S/E of 2’x2’ LED fitting recess type with intergral/ non integral driver to be installed recess in false ceiling. The fitting should be Philips/ Wipro/ Bajaj/ Havells/ Crompton/ Jaquar/ Twinkle make only. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of EIC as per DNIT Item No.14. | NSR17 | 19 | nos. |
26 | 15 | S/E of LED box type fittings made of CRCA Sheet. The fittings should be installed on existing surface. The tube rod should be of Philips/ Wipro/ Bajaj/ Twinkle/ Havells/ Crompton/ Jaquar/ Surya make only. The batten for hosing the 1 No. tube rods should be of Philips/ Wipro/ Bajaj/ Twinkle/ Havells/ Crompton/ Jaquar/ Surya make only. The job includes carriage, erection, making connections testing and commissioning of the fittings as per DNIT Item No.15. | NSR18 | 24 | nos. |
27 | 16 | S/E of LED box type fittings made of CRCA Sheet. The fittings should be installed on existing surface. The tube rod should be of Philips/ Wipro/ Bajaj/ Twinkle/ Havells/ Crompton/ Jaquar/Surya make only. The batten for hosing the 2 Nos. tube rods should be of Philips/ Wipro/ Bajaj/ Twinkle/ Havells/ Crompton/ Jaquar/ Surya make only. The job includes carriage, erection, making connections testing and commissioning of the fittings as per DNIT Item No.16. | NSR19 | 2 | nos. |
28 | 17 | S/E of AC ceiling fans with copper winding but without regulator complete with Aluminium blades, plastic canopies 2 Nos. double ball bearing, MS hanging rods (As per site requirement), condenser, reels, clamps etc. The body of fan and blades should be white in colour. The job includes the cost of making necessary connections from the adjacent light point with 1.5mm2 single core copper conductor cable and 3mm thick white B.L. sheet cover for fan box of suitable size. The sample of fans shall be got approved from the SDE in-charge of work before installation at site. The job also includes the cost of carriage, erection, testing, commissioning of fan, all labour and petty material required to complete the job to the entire satisfaction of the SDE-In-Charge. | |||
29 | 17.01 | Size 56” (1400mm) sweep ceiling fan of Crompton (High Speed) / Havells (Velocity HS) / Orient (Newbreeze) white / Bajaj Speedster only. | NSR20 | 20 | nos. |
30 | 18 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. | |||
31 | 18.01 | Size 15 inches (380mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Crompton (EXHD380-6-1) / Bajaj (Supreme Dlx 380) / Orient (15” Industrial Heavy Duty) make only. | NSR21 | 4 | nos. |
32 | 18.02 | Size 12 inches (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Crompton (EXHD300-6-1) / Bajaj (Supreme Dlx 300) / Orient (15” Industrial Heavy Duty) make only. | NSR22 | 1 | nos. |
33 | 19 | Providing and fixing following rating MCCB 4 pole 415 volt with MS enclosure having insulation voltage Ui=690 volt, impulse withstand voltage Uimp=8 KV and breaking capacity 36 KA (Ics=100%Icu) with thermal magnetic/ microprocessor release for over load and short circuit protection. The overload & short circuit protection. The overload and short circuit release shall be of adjustable type. The MCCB is to be installed in existing cubicle panel/ angle iron board including drilling holes in cubicle panel/ angle iron board, making connection with suitable rating of copper wire/ copper strip etc as required. The job includes the cost of copper spreaders terminal links and direct/ extended rotary handle etc as required. The MCCB should be of make L&T/ Schneider/ Siemens/ ABB/ Legrand make only. | |||
34 | 19.01 | 63/100Amp 4 Pole MCCB (Thermal Magnetic release). | NSR23 | 1 | nos. |
35 | 20 | S/E of sheet metal 3 phase bus-bur chamber on existing surface with required no. of bus-bar strips of suitable 1.6 mm thick with detachable cover fitted with dust excluding gasket and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with GI bolts and nuts/rag bolts and nuts etc. complete with all accessories including connections with suitable size tin coated copper thimbles, bonding to the existing earth & painting etc as desired by the EIC. | |||
36 | 20.01 | Sheet metal bus-bar chamber 400 amp 415 V capacity with 4 copper strip 3 feet long | NSR24 | 4 | rn.ft. |