Department Of Electronics And Information Technology has published Hiring Of Colocation Services Hiring Of Co-Location Services For Primary And Disaster Recovery ( Dr ) Data Centers For Nccc. Submission Date for this Tender is 16-02-2021. LAN Tenders in LOCATION AS PER BIDDER PROPOSAL Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 08-Feb-2021 | DATE EXTENSION | Date | 16-02-2021 |
2 | 09-Feb-2021 | CORRIGENDUM_BOQ | Financial Bid | 16-02-2021 |
Name of Work: HIRING OF CO-LOCATION SERVICES FOR PRIMARY AND DISASTER RECOVERY (DR) DATA CENTRES FOR NCCC | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | ONETIME CHARGES for Racks (IPDUs, configuration and rack charges etc) in Primary Data Centre ( DC) | |||
2 | 1.01 | Configuration of Racks in Phase 1 | item1 | 1 | Nos |
3 | 1.02 | Configuration of Racks in Phase 2 | item2 | 1 | Nos |
4 | 1.03 | Configuration of Racks in Phase 2 | item3 | 1 | Nos |
5 | 2 | ONETIME CHARGES for Racks (IPDUs, configuration and rack charges etc) in DISASTER RECOVERY ( DR) | |||
6 | 2.01 | Configuration of Racks in Phase 2 | item4 | 1 | Nos |
7 | 2.02 | Configuration of Racks in Phase 3 | item5 | 1 | Nos |
8 | 3 | RECURRING CHARGES for Primary Data Centre Location (Charges for\nPower,cooling etc if any) - ( Year-1) | |||
9 | 3.01 | 42U Rack Space with 16 KW (20KVA) power consumption | item6 | 1 | Nos |
10 | 3.02 | 42U Rack Space with 12 KW (15KVA) power consumption | item7 | 1 | Nos |
11 | 3.03 | 42U Rack Space with 10 KW (12.5KVA) power consumption | item8 | 1 | Nos |
12 | 3.04 | 42U Rack Space with 8 KW (10KVA) power consumption | item9 | 1 | Nos |
13 | 4 | RECURRING CHARGES for Primary Data Centre Location (Charges for\nPower,cooling etc if any) - ( Year-2) | |||
14 | 4.01 | 42U Rack Space with 16 KW (20KVA) power consumption | item10 | 1 | Nos |
15 | 4.02 | 42U Rack Space with 12 KW (15KVA) power consumption | item11 | 1 | Nos |
16 | 4.03 | 42U Rack Space with 10 KW (12.5KVA) power consumption | item12 | 1 | Nos |
17 | 4.04 | 42U Rack Space with 8 KW (10KVA) power consumption | item13 | 1 | Nos |
18 | 5 | RECURRING CHARGES for Primary Data Centre Location (Charges for\nPower,cooling etc if any) - ( Year-3) | |||
19 | 5.01 | 42U Rack Space with 16 KW (20KVA) power consumption | item14 | 1 | Nos |
20 | 5.02 | 42U Rack Space with 12 KW (15KVA) power consumption | item15 | 1 | Nos |
21 | 5.03 | 42U Rack Space with 10 KW (12.5KVA) power consumption | item16 | 1 | Nos |
22 | 5.04 | 42U Rack Space with 8 KW (10KVA) power consumption | item17 | 1 | Nos |
23 | 6 | RECURRING CHARGES for DISASTER RECOVERY Location (Charges for\nPower,cooling etc if any) - ( Year-1) | |||
24 | 6.01 | 42U Rack Space with 16 KW (20KVA) power consumption | item18 | 1 | Nos |
25 | 6.02 | 42U Rack Space with 12 KW (15KVA) power consumption | item19 | 1 | Nos |
26 | 6.03 | 42U Rack Space with 10 KW (12.5KVA) power consumption | item20 | 1 | Nos |
27 | 6.04 | 42U Rack Space with 8 KW (10KVA) power consumption | item21 | 1 | Nos |
28 | 7 | RECURRING CHARGES for DISASTER RECOVERY Location (Charges for\nPower,cooling etc if any) - ( Year-2) | |||
29 | 7.01 | 42U Rack Space with 16 KW (20KVA) power consumption | item22 | 1 | Nos |
30 | 7.02 | 42U Rack Space with 12 KW (15KVA) power consumption | item23 | 1 | Nos |
31 | 7.03 | 42U Rack Space with 10 KW (12.5KVA) power consumption | item24 | 1 | Nos |
32 | 7.04 | 42U Rack Space with 8 KW (10KVA) power consumption | item25 | 1 | Nos |
33 | 8 | RECURRING CHARGES for DISASTER RECOVERY Location (Charges for\nPower,cooling etc if any) - ( Year-3) | |||
34 | 8.01 | 42U Rack Space with 16 KW (20KVA) power consumption | item26 | 1 | Nos |
35 | 8.02 | 42U Rack Space with 12 KW (15KVA) power consumption | item27 | 1 | Nos |
36 | 8.03 | 42U Rack Space with 10 KW (12.5KVA) power consumption | item28 | 1 | Nos |
37 | 8.04 | 42U Rack Space with 8 KW (10KVA) power consumption | item29 | 1 | Nos |
38 | 9 | RECURRING CHARGES for INTERNET BANDWIDTH | |||
39 | 9.01 | 100 Mbps Internet Bandwidth for Central Location- First Year | item30 | 1 | Nos |
40 | 9.02 | 100 Mbps Internet Bandwidth for Central Location- Second Year | item31 | 1 | Nos |
41 | 9.03 | 100 Mbps Internet Bandwidth for Central Location- Third Year | item32 | 1 | Nos |