Electrification Of Gau Vansh Sanrakshan Kendra Saujana Block Mehroni District Lalitpur . , Jhansi-Uttar Pradesh

Public Works Department-PWD has published Electrification Of Gau Vansh Sanrakshan Kendra Saujana Block Mehroni District Lalitpur . . Submission Date for this Tender is 08-02-2021. Electrification Work Tenders in Jhansi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26646636
Electrification Of Gau Vansh Sanrakshan Kendra Saujana Block Mehroni District Lalitpur .
Open Tender
Indian
Uttar Pradesh
Jhansi
08-02-2021

Tender Details

Electrification Of Gau Vansh Sanrakshan Kendra Saujana Block Mehroni District Lalitpur .

Key Value

Document Fees
INR 677 /-
EMD
INR 34000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:-Electrification of Gau Vansh Sanrakshan Kendra Saujana Block Mehroni District Lalitpur.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Wiring point for Light point One Way with 1.5mm² FR PVC Insulated with M/S copper wire with 1.5mm² Insulated M/S copper wire as earth wire drown in PVC pipe partly laid in slab & partly load in the wall with modular tyhe switch, ceilling rose/angle/Batten Holder bucket sheet etc complete in all respect.\n(For Office)\nP.S.No:-131(c)+187(A) 5 Nos
2 2 Wiring point for Ceilling Fan/Fresh air Fan Point with 1.5mm² FR PVC Insulated with M/S copper wire with 1.5mm² Insulated M/S copper wire as earth wire drown in PVC pipe partly laid in slab & partly load in the wall with modular tyhe switch, ceilling rose/angle/Batten Holder bucket sheet etc complete in all respect.\n(For Office)\nP.S.No:-133(c)+187(A) 2 Nos
3 3 Wiring point for Plug Point with 1.5mm² FR PVC Insulated with M/S copper wire with 1.5mm² Insulated M/S copper wire as earth wire drown in PVC pipe partly laid in slab & partly load in the wall with modular tyhe switch, ceilling rose/angle/Batten Holder bucket sheet etc complete in all respect.\n(For Office)\nP.S.No:-134(c)+187(c) 3 Nos
4 4 Wiring point for Light point One Way with 1.5mm² FR PVC Insulated with M/S copper wire with 1.5mm² Insulated M/S copper wire as earth wire drown in PVC pipe on surface with flush tyhe switch, ceilling rose/angle/Batten Holder bucket sheet etc complete in all respect.\n(For Catle Shade)\nP.S.No:-121(c) 25 Nos
5 5 Wiring point for Ceilling Fan/Fresh air Fan Point with 1.5mm² FR PVC Insulated with M/S copper wire with 1.5mm² Insulated M/S copper wire as earth wire drown in PVC pipe partly laid in slab & partly load in the wall with modular tyhe switch, ceilling rose/angle/Batten Holder bucket sheet etc complete in all respect.\n(For Catle Shade)\nP.S.No:-123(c) 12 Nos
6 6 Wiring point for Plug Point with 1.5mm² FR PVC Insulated with M/S copper wire with 1.5mm² Insulated M/S copper wire as earth wire drown in PVC pipe partly laid in slab & partly load in the wall with modular tyhe switch, ceilling rose/angle/Batten Holder bucket sheet etc complete in all respect.\n(For Office)\nP.S.No:-124(c) 4 Nos
7 7 Add for invertor wiring point for light/fan /plug.\nP.S.No:-189(A) 7 Nos.
8 8 S/F of 15A/250V power plug fush type modular switch and 5 pin 15A/250V flush type universal modular socket on concealed M.S. Box including supply of all material labour T&P etc. required for proper completion of the work.\nP.S.No:-1139 4 Nos.
9 9 S/F of 4way TPNDB with additional Metal Door with MCB Complete in all respect.\nP.S.No:-1026(A) + 1002 Cat B 1 Nos.
10 10 S&F of 32 Amp. 415 V metal clad TPN rewraht type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect.\nP.S.No:-315 Cat B 1 Nos.
11 11 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. \nP.S.No:-1413 Cat AA 14 Nos.
12 12 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 30 watt to 40 Watt. Confirming to IP66 Protection complete in all respect. \nP.S.No:-1420 Cat AAA 20 Nos.
13 13 S/L of 2.5sq.mm 2 wire. size submain copper conductor cable in concealed PVC conduit.\nP.S.No:-1304 (c) 80 Mtr.
14 14 S/L of 6.00sq.mm 2 wire. size submain copper conductor cable in concealed PVC conduit.\nP.S.No:-217 (c) 25 Mtr.
15 15 S/L of 10.00sq.mm 4 wire. size submain copper conductor cable in concealed PVC conduit.\nP.S.No:-273 (c) 30 Mtr.
16 16 S/F of 4 sq.mm sized cu. Lugs for submain/PVC aluminium cable.\nP.S.No:-504 (a) 18 Nos.
17 17 S/F of 6 sq.mm sized cu. Lugs for submain/PVC aluminium cable.\nP.S.No:-504 (b) 8 Nos.
18 18 Supply and fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work.\nP.S.No:-1203 (A) 13 Nos.
19 19 Supply and burying of 600mm x 600mm x 3mm GI plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respect.\nP.S.No:-703 2 Nos.
20 20 Supply and fixing of Two number 8 SWG GI wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site.\nP.S.No:-723 60 Mtr.
21 21 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.\nP.S.No:-1131 4 Nos.
22 22 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge.\nP.S.No:-1133 8 Nos.
23 23 Supply and fixing of 16 SWG M.S. drum with luvers duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect.\nP.S.No:-1122 (A) 1 Nos.
24 24 Supply of ceiling fans with fan motor of AC permanent insulated, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down rod blades, shackle canopies etc. and with double ball bearing system. BEE 5 star rated-1200mm sweep.\nP.S.No:-1501 (i) 13 Nos.
25 25 S/F of Freah Air 300mm size excluding cartage and fixing Complete in all respects.\nTS:-56(E)/SE E-17E/M 2019-20 1 Nos.
26 26 S/F of LED lamp 10 W approved make.\nT.S. No:-19CE(E/M)-17E/M/20-21 Dt:-06/2020 16 Nos.
27 27 S/F of 4 ways SPNDB with add. Metal door with 2 Nos. MCB & 32 amp. DPMCB Complete in all respects.\nP.S. No:-1022 + 1022 [A] + 1009 Cat B 5 Nos.
28 28 S&F surface/flush mounting 8ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge.\nP.S. No:-1024 [A] + 1002 + 1009 Cat B 1 Nos.
29 29 Supply and laying of 10 mm 2 core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. \nP.S. No:-501 (b) 140 Mtr.
30 30 Supply and laying of 16 mm 4 core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. \nP.S. No:-501 (i) 60 Mtr.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail