Provision Of Timer Switch With Lt Feeder For Timer Based Street Light , Spl Repair To Garden Lights , Replacement Of Gi To Copper Earthing , Water Cooler And Exhaust Fan At Ins Hamla And Addnaltn To Security Lights At Erangle Under Ge Nw Bhandup Provi, HAMLA-Maharashtra

Military Engineer Services-MES has published Provision Of Timer Switch With Lt Feeder For Timer Based Street Light , Spl Repair To Garden Lights , Replacement Of Gi To Copper Earthing , Water Cooler And Exhaust Fan At Ins Hamla And Addnaltn To Security Lights At Erangle Under Ge Nw Bhandup Provi. Submission Date for this Tender is 11-02-2021. Electrification Work Tenders in HAMLA Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

26646199
Corrigendum : Provision Of Timer Switch With Lt Feeder For Timer Based Street Light , Spl Repair To Garden Lights , Replacement Of Gi To Copper Earthing , Water Cooler And Exhaust Fan At Ins Hamla And Addnaltn To Security Lights At Erangle Under Ge Nw Bhandup Provi
Open Tender
Indian
Maharashtra
HAMLA
11-02-2021

Tender Details

Provision Of Timer Switch With Lt Feeder For Timer Based Street Light , Spl Repair To Garden Lights , Replacement Of Gi To Copper Earthing , Water Cooler And Exhaust Fan At Ins Hamla And Addnaltn To Security Lights At Erangle Under Ge Nw Bhandup Provision Of Timer Switch With Lt Feeder For Timer Based Street Light , Spl Repair To Garden Lights , Replacement Of Gi To Copper Earthing , Water Cooler And Exhaust Fan At Ins Hamla And Addn Altn To Security Lights At Erangle Under Ge Nw Bhandup

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-02-2021
2 05-Feb-2021 DATE CORRIGENDUM Date 08-02-2021
3 09-Feb-2021 DATECORRIGENDUM Date 11-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 83000.0 /-
Tender Value
INR 41.50 Lakhs /-

BOQ Items

NAME OF WORK: PROVISION OF TIMER SWITCH WITH LT FEEDER FOR TIMER BASED STREET LIGHT, SPL REPAIR TO GARDEN LIGHTS, REPLACEMENT OF GI TO COPPER EARTHING, WATER COOLER AND EXHAUST FAN AT INS HAMLA AND ADDN/ALTN TO SECURITY LIGHTS AT ERANGLE UNDER GE (NW) BHANDUP
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge. 475 Cum
2 2 Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge. 47 Cum
3 3 Returning, filling in including spreading , leveling , watering and well ramming in layers n.exc 25 cm with soil complete all as specified and as directed by the Engineer-in- Charge. 428 Cum
4 4 Supply and laying HDPE pipes of pressure rating 6 Kg/Cm sq of size 40 mm laid in trenches complete all as specified and directed. 650 RM
5 5 Supply and laying HDPE pipes of pressure rating 6 Kg/Cm sq of size 50 mm laid in trenches complete all as specified and directed. 950 RM
6 6 Supply and laying cable LT XLPE insulated and screened PVC bedded, galvanised steel strip armoured electric power cable 10 sq mm 2 core (heavy duty) with stranded aluminium conductor, 1100 Volts grade complete all as specified and directed by Engineer in charge. 800 RM
7 7 Supply and laying cable LT XLPE insulated and screened PVC bedded, galvanised steel strip armoured electric power cable 16 sq mm 4 core (heavy duty) with stranded aluminium conductor, 1100 Volts grade complete all as specified and directed by Engineer in charge. 1000 RM
8 8 M&L for reinforced cement conrete 1:2:4, type B-1 (using 20mm graded stone aggregate) for foundations, footings, columns, postd, pillars etc & in aany location, complete all as specified and direccted. (Note: Reinforcement and dorm work will be measured and paid separetly) 23 Cum
9 9 M&L for 500 D TMT steel bars 10 mm dia and over in reinforcement cut to length,bent to shape required,including cranking bending spirally forhooping for coloumns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm di or ecuring with clips etc, complete all as specified and directed 225 KG
10 10 M&L for 500 D TMT steel bars 6 to 8 mm dia as in strirups, spacers, binders cut to length,bent to shape required,including cranking bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips etc, complete all as specified and directed 150 KG
11 11 Supply and drawing through the pole for making connection to the light fittings,three core,PVC insulated and sheathed ,Heavy duty ,1100 volts grade,multistranded copper conductor(FRLS) cable 2.5 sqmm, complete all as specified and directed. 400 RM
12 12 M&L for use and waste of formwork to sides of concrete foundations, footing, columns, posts pillars etc and in any location for fair finished surfaces,complete all as specified and directed 75 Sqm
13 13 Supply and fix highly efficient multi LED Street light 72 watt with pressure die cast aluminium housing, reflector and enclosed with toughened glass, IP65 including taking down old unserviceable MH flood light fittings complete all as specified and directed. 40 Nos
14 14 Taking down old one and S&F 7 metre long hot dipped galvanised octagonal poles with top A/F 70 mm bottom A/F 130 mm ,made out of 3 mm thick HT sheet alongwith base plate of size 220x220x12mm ,including 1500 mm long single/double arm bracket made out of 48 mm dia,GI pipe,M20 in PCD 205 mm,700mm long and projected 100mm,"J" type EN8 grade set of 4 Nos foundation bolts along with tempalates,also including provision of the followings :- a)MCB,SP,6A,230v,B series,10KA mounted on and including 3 mm thick plastic laminated sheet-01 No. b) 4 way connector ,bolt type having locking arrangement,weather proof and water proof control space: 01 No. \nNotes :- \na) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete.\n b) The rate quoted shall also be deemed to include the cost for connecting with including suitable lugs of the existing incoming and outgoing LT UG cable of any size in the pole box of new octagonal pole. \nc) The concrete for foundation ,Reinforced and form work will measured and paid seperately.\nd) The excavation and earth work for foundation of pole shall be measured and paid separately 40 Each
15 15 Supply and Fixing GI tubing, medium grade 50 mm dia for garden light post 1.5 mtr/2 mtr long complete (for 50 Nos garden light) all as specified and directed. 120 RM
16 16 Supply and fix in replacement of Decorative LED Post-Top 18 watt made in cast aluminium spigot housing with decorative opal diffuser and IP 65 protection complete including cable connection and taking down existing unserviceable pot top lantern Make - Shakti cat part No. SZPGPMX018 complete all as specified and directed. 50 Each
17 17 Supply and fix in replacement of Decorative LED Bolard/Bamboo type 9 watt 600 TO 900 MM Length made in cast aluminium spigot housing with decorative opal diffuser and IP 65 protection complete including cable connection and taking down existing unserviceable light Make - Shakti cat part No. SZPGBMX009 complete all as specified and directed. 25 Each
18 18 Supply and fixing in replacement pole mounting box FRP type of size 140mm x 140mm x 100 mm, 3 phase with locking arrangements, lugs and including necessary nut, bolt and clamps of the flat iron of size 25mm x 4 mm comprising of MCB SP 6 Amps, 240 Volts, 10 KA, 'C' series with proper fixing arrangements on pole / wall complete all as specified and directed. 50 Each
19 19 Taking down fan , sealing cable end , dismantling blades and removing fan and blades to store 52 Nos
20 20 Supply & fix exhaust fan 300 mm sweep, 900 rpm, 230V complete with louvers, steel body, bolts, nuts, washers, suitably embedded in wall with provisioning of 23/0.0076 flexible three core wire for electrical connections from ceiling rose to fan and wall cutting suitable size all as specified and directed. 34 Each
21 21 Supply & fix exhaust fan 450 mm sweep, 900 rpm, 230V complete with louvers, steel body, bolts, nuts, washers, suitably embedded in wall with provisioning of 23/0.0076 flexible three core wire for electrical connections from ceiling rose to fan all as specified and directed. 8 Each
22 22 Supply & fix exhaust fan 200 mm sweep, 230V , plastic body, with bolts, nuts, washers, suitably embedded on the window with provisioning of 23/0.0076 flexible three core wire for electrical connections from ceiling rose to fan and fitting and fixtures ie carpenter work for fixing on window all as specified and directed. 10 Each
23 23 Supply & installation, commissioning water cooler inbuilt UV purifier Electric driven single phase 240 V 50 Hz having approx storage capacity of 80 Ltr and nominal cooling capacity of 40 Ltr per Hour all as specified and directed. 8 Each
24 24 M&L for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper strip of size 25x3 mm as earthing lead means of nut, bolts and washers made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to Transformer Neutral/body or as directed by Engr -in-Charge including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Agg-regate) and RCC Cover of size 450X450X50mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and Testing on completion , complete all as specified and as directed. 50 Each
25 25 M&L for copper strip 25x3 MM fixed to wall with suitable size insulator all as specified and directed. 30 RM
26 26 Supply, installing, testing and commissioning factory made and tested LT Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. hall be dust and vermin proof, protection class (IP-54) and made of 2.00 mm thick Stainless Steel Sheet 316L & suitable frame work/ support made out of 40 x 40 x 5 mm Aluminium, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- Make:- Havells/ Schneider / ABB/ L&T/ Universal Switch Gear Control.\nINSTRUMENT CHAMBER:-\n(i) RYB Phase indicating light LED type- 01 Set.\nINCOMING:-\n(i) MCB 63 Amps, 4 Pole, 10 KA, 50 Hz, 415 Volts-01 No. Make: L&T/ Havells / Legrand\n(ii) Power Contactor 3 Pole, 70 Amps. 50 Hz, 415 Volts- 01 No. Make: L&T/ Havells or equivalent.\n(iii) Time Switch electronic type, one dial daily, 240/415 Volts, \n50 Hz- 01 No. Make: L&T/ Havells or equivalent.\n(iv) A/M Selector Switch 6 A - 01 No. Make: L&T/Schneider.\n(v) RED Phase indicating light LED type- 01 No.. Make: L&T/Vishnu/ Schneider.\nPanel wiring for control circuit with copper flexible 1.5 Sq mm & \npower wiring 10 Sqmm flexible.\nNote: In Case of failure, manual system should also be provided.The panel manufacturer should have following Govt. Approved Certificates: \n1. CPRI Certification Degree of Protection IP-54 2. CPRI Certification Short Circuit withstand strenght should be 50kArms for 1.0 Sec with intial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED 6 Each
27 27 M&L for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI earth strip 32X6 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed. 12 Each
28 28 Deduct Credit for Demolished/ Dismantled material Rs. (-) 69,100.00 (Minus) as listed in Schedule of Credit Note: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'