}

Installation Of Lougram Solar Mini Rli Under Kotulpur Block Under Bishnupur Sub Division Under Bankura ( Am ) Division Under Ridf Xxvi Programme 2020-21, Bankura-West Bengal

Water Resources Department-WRD has published Installation Of Lougram Solar Mini Rli Under Kotulpur Block Under Bishnupur Sub Division Under Bankura ( Am ) Division Under Ridf Xxvi Programme 2020-21. Submission Date for this Tender is 05-02-2021. Lift Irrigation Tenders in Bankura West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

26637957
Installation Of Lougram Solar Mini Rli Under Kotulpur Block Under Bishnupur Sub Division Under Bankura ( Am ) Division Under Ridf Xxvi Programme 2020-21
Open Tender
Indian
West Bengal
Bankura
05-02-2021

Tender Details

Installation Of Lougram Solar Mini Rli Under Kotulpur Block Under Bishnupur Sub Division Under Bankura ( Am ) Division Under Ridf Xxvi Programme 2020-21

Key Value

Document Fees
Refer document
EMD
INR 39520.0 /-
Tender Value
INR 19.75 Lakhs /-

BOQ Items

Name of Work:- Installation of Lougram Solar Mini RLI under Kotulpur Block Under Bishnupur Sub Division under Bankura(AM) Division Under RIDF XXVI Programme
Sl. No. Item Description Item Code / Make Quantity Units
1 1 DBMS:-Conduct of an awarness meeting among villagers for collection of mouza map including spout wise list of benificiary with plot number & quatity of irrigated area for each farmer for sustainability of the irigation structure in future.the expenses of the programme head as follows .meeting arangement,tea,and biscuits,travelling expens,service charge etc. BI01010001010000000000000515BI0100001113 1 Each Side
2 2 Preparation the documents of the association of list of benificiary with benifitted area agaist each spout . The expences of the programme head as follows typing,printing,Preapration of the set documents service charge etc BI01010001010000000000000515BI0100001114 1 Each Side
3 3 Field visit for for cross check up of spout wise benificiary list including their area to be irrigated. The expences of the programme head as follows.Travelling expences,service charge etc. BI01010001010000000000000515BI0100001115 1 Each Side
4 4 Collection of data like plot number, latitude & lognitude of P.H., D.C., & each spout & Preparation of documents & submission of same to the office in duplicate.The expences of the programme head as follows.Collecting,typing,Printing,Preparation of the set documents,service charge etc. BI01010001010000000000000515BI0100001116 1 Each Side
5 5 Collection of phatography like prework, ongoing & post work covering lay-out,pipe trenches,trenches with pipe before earth filling, measurment ,final work with name plate, & submission of same to the office in duplicate.The expences of the programme head as follows.Collecting,typing,Printing,Preparation of the set documents,service charge etc. BI01010001010000000000000515BI0100001117 1 Each Side
6 6 Submission of soft copy( by a DVD) of all above data like spout wise benificiary list including area of irrigated land of each farmer, phtography, latlong of P.H., D.C.,& each spout chamber in duplicate. the programme head as follows Preparation of the set documents,service charge etc. BI01010001010000000000000515BI0100001118 1 Each Side
7 7 WUA:-Conduct of an awarness meeting among villagers for mobilazation of community towards formation of a committee for sustainability of the irigation structure in future.the expenses of the programme head as follows .meeting arangement,tea,and biscuits,travelling expens,service charge etc. BI01010001010000000000000515BI0100001119 1 Each Side
8 8 preparation the documents of the association of water users for WUA registration Act 1961 . The expences of the programme head as follows typing,printing,Preapration of the set documents service charge etc BI01010001010000000000000515BI0100001120 1 Each Side
9 9 field visit for signature of the registration paper of the WUA members. The expences of the programme head as follows.Travelling expences,service charge etc. BI01010001010000000000000515BI0100001121 1 Each Side
10 10 Preparation of the whole registration documents with authorization paper by WUA and department.The expences of the programme head as follows.typing,Printing,Preparation of the set documents,service charge etc. BI01010001010000000000000515BI0100001122 1 Each Side
11 11 Submission of the registration documents of WUAat kolkta for getting registration certificate under society registration act 1961.The expences of of the programme head follows travelling expences, food and lodging expences to kolkata and return ,service charge etc. BI01010001010000000000000515BI0100001123 1 Each Side
12 12 Participation in hearing for WUA registration confirmation at society registration office.the expences of the programme head as follows. Travelling expences, food and lodging expences to kolkata and return ,service charge etc. BI01010001010000000000000515BI0100001124 1 Each Side
13 13 collection of WUA certificate. The expences of the programme Head as follows Travelling expences, food and lodging expences to kolkata and return ,service charge etc. BI01010001010000000000000515BI0100001125 1 Each Side
14 14 MATERIAL:-140 mm. dia P.V.C. pipe Class- I 140(with a loose matching coupler,class-II) marking IS No. 4985/ 1988 with latest amendments with free solvent cement. BI01010001010000000000000515BI0100001126 252 Meter
15 15 110 mm. dia P.V.C. pipe Class- I (with a loose matching coupler,class-II) marking IS No. 4985/ 1988 with latest amendments with free solvent cement. BI01010001010000000000000515BI0100001127 1200 Meter
16 16 110 mm. dia P.V.C. pipe class-II ( with a loose matching coupler,class-II) marking IS No. 4985/ 1988 with latest amending with free solvent cement. BI01010001010000000000000515BI0100001128 12 Meter
17 17 Coupler(Cl-II) for 140 mm. dia P.V.C. pipe ( extra) I.S. 10124/1988, Part- II with free solvent cement. BI01010001010000000000000515BI0100001129 11 Each
18 18 Coupler(Cl-II) for 110 mm. dia P.V.C. pipe ( extra) I.S. 10124/1988, Part- II with free solvent cement. BI01010001010000000000000515BI0100001130 50 Each
19 19 110x110x 110 M. P.V.C. Tee with free solvent cement BI01010001010000000000000515BI0100001131 9 Each
20 20 140x140x 140 M. P.V.C. Tee with free solvent cement BI01010001010000000000000515BI0100001132 2 Each
21 21 140 x 110 Reducer(cl-II) with free solvent cement. BI01010001010000000000000515BI0100001133 4 Each
22 22 140 mm. dia 900 bend (cl-II) ( IS. No. 10124/ 88 Part- 8 with latest amendment ) BI01010001010000000000000515BI0100001134 2 Each
23 23 110 mm. dia 600 bend(cl-II) ( IS. No. 10124/ 88 Part- 8 with latest amendment ) BI01010001010000000000000515BI0100001135 6 Each
24 24 110 mm. dia 900 bend(cl-II) ( IS. No. 10124/ 88 Part- 8 with latest amendment ) BI01010001010000000000000515BI0100001136 13 Each
25 25 140 mm. dia IS. NO. 10124/ 88 Part- 4 with latest amendment End cap. BI01010001010000000000000515BI0100001137 1 Each
26 26 110 mm.dia IS.NO.10124/88 Part-4 with latest amendment.PVC End Cap.(Cl-III) BI01010001010000000000000515BI0100001138 2 Each
27 27 110 mm. dia ( IS. No 10124/88 Part- 6 with latest amendment) F.T.P.(Cl-II) BI01010001010000000000000515BI0100001139 9 Each
28 28 140 mm. dia ( IS. No 10124/88 Part- 6 with latest amendment) F.T.P.(Cl-II) BI01010001010000000000000515BI0100001140 2 Each
29 29 ISI marked P.V.C.Flexible Hose pipe as per IS 15265 - 100 mm dia BI01010001010000000000000515BI0100001141 60 Meter
30 30 Solvent cement extra (Medium duty) BI01010001010000000000000515BI0100001142 2.5 Litre
31 31 M.S. Tripod set for Mini RLI BI01010001010000000000000515BI0100001143 1 Set
32 32 150 mm dia G.I. E.R.W. Pipe with flange as per IS 1239 (Part-I)/2004 & 6392/1971, table 17 Specification. BI01010001010000000000000515BI0100001144 48 Meter
33 33 100 mm dia G.I E.R.W. Pipe with flange as per IS 1239 (Part-I)/2004 & 6392/1971, table 17 Specification. BI01010001010000000000000515BI0100001145 24 Meter
34 34 150 mm. dia I.S.I. 14846/2000 Amd No. 1&2 mark and specification PN- 1.6 sluice valve . BI01010001010000000000000515BI0100001146 2 Each
35 35 100 mm dia C.I. Sluice Valve I.S.I. 14846/2000 Amd No. 1&2 mark and specification PN- 1.6 sluice valve . BI01010001010000000000000515BI0100001147 2 Each
36 36 ?100 mm NTP /Alfa-Alfa Valve as per technical specification BI01010001010000000000000515BI0100001148 9 Each
37 37 100 mm dia 90º G.I bend (With priming arrangement) ISI 1239 (Part-II)/1992 Specification mark BI01010001010000000000000515BI0100001149 2 Each
38 38 100 mm dia. Foot Valve Threaded type IS: 4038/1986 BI01010001010000000000000515BI0100001150 2 Each
39 39 100 mm dia, 2mm thickness,30mm width Heavy Duty Hose Clamp fitted with bolts & nuts BI01010001010000000000000515BI0100001151 20 Each
40 40 100 mm dia C.I Tail piece one End flanged other End Grooved BI01010001010000000000000515BI0100001152 6 Each
41 41 100 mm dia C.I. combind Tail Piece with adopter both side grooved BI01010001010000000000000515BI0100001153 2 Each
42 42 80X65mm M.S. flanged reducer BI01010001010000000000000515BI0100001154 2 Each
43 43 100X80mm M.S. flanged reducer BI01010001010000000000000515BI0100001155 4 Each
44 44 M.S Foundation Bolt for Pump motor sets (1.1kg each) BI01010001010000000000000515BI0100001156 8 nos
45 45 M.S Foundation Bolt for distribution chamber (1.1kg each) BI01010001010000000000000515BI0100001157 14 nos
46 46 Nuts & Bolts IS: 1363 (Part 1 & 3) /1992 of Product Grade-C.M-20 X 80 mm BI01010001010000000000000515BI0100001158 50 kg
47 47 M-20 X 100 mm BI01010001010000000000000515BI0100001159 10 kg
48 48 M-16 X 65 mm BI01010001010000000000000515BI0100001160 44 kg
49 49 M-16 X 80 mm BI01010001010000000000000515BI0100001161 10 kg
50 50 M-16 X 50 mm BI01010001010000000000000515BI0100001162 18 kg
51 51 Foot valve leather washer 100mm dia BI01010001010000000000000515BI0100001163 2 Each
52 52 Sal Sleeper (4ft X 6in X 4 in) BI01010001010000000000000515BI0100001164 2 Each
53 53 Compresed Asbestos fibre jointing for Quadruped & Tripod set( for raised surface of Flange as per IS-6392)300mm.dia(Table-5) BI01010001010000000000000515BI0100001165 2 Each
54 54 Rubber Insertion I.S. 638/79 with latest amendment sheet 5 mm. 2 Ply. ( for raised surface of Flange as per IS-6392)150 m dia Ruber Insertion(Table-17) BI01010001010000000000000515BI0100001166 18 Each
55 55 150 m dia Ruber Insertion(Table-5) BI01010001010000000000000515BI0100001167 8 Each
56 56 100 m dia Ruber Insertion(Table-17) BI01010001010000000000000515BI0100001168 21 Each
57 57 80 m dia Ruber Insertion (Table-17) BI01010001010000000000000515BI0100001169 11 Each
58 58 (ii) 3C X 4 sqmm copper cable conforming to IS 694 [Busbar to 32 A, TP Main switch and 32 A TP switch to Motor starter] BI01010001010000000000000515BI0100001170 3 RM
59 59 (iii) 2 X 3C X 2.5 sqmm copper cable conforming to IS 694 in 25 mm GI conduit (ISI-Medium quality)[ Star-Delta Motor starter to Motor] BI01010001010000000000000515BI0100001171 10 RM
60 60 LAYING:-Earth work in excavation of field trenches as per design section and alignment for laying of pipe lines (PVC, RCC, ACP etc.) upto a depth of 1500 mm all sorts of soils including removing, spreading or stacking extra earth as directed. The item includes necessary trimming of sides trenches, levelling, dressing and ramming the bottom as required complete .\n(a) Depth of excavation not exceeding 1,500 mm.i)For foundation Blocks of Tripod BI01010001010000000000000515BI0100001172 3.4
61 61 ii) For spout Chambers BI01010001010000000000000515BI0100001173 17
62 62 iii) For Pipe Trenches BI01010001010000000000000515BI0100001174 1000
63 63 Earth work in filling in trenches after laying pipe lines (PVC, RCC, ACP etc.) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc. layer by layer complete. (Payment will be made on the basis of measurement of finished quantity of work.) BI01010001010000000000000515BI0100001175 950 m3
64 64 Laying of UPVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittigs and solvent cement to be supplied by deptt.) all complete asper direction of Engineer-In- charge. i) 140 mm.OD. BI01010001010000000000000515BI0100001176 260 m
65 65 ii) 110 mm. OD. BI01010001010000000000000515BI0100001177 1240 m
66 66 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. i)For foundation Blocks of Tripod BI01010001010000000000000515BI0100001178 3.5 m2
67 67 ii) For spout Chamber BI01010001010000000000000515BI0100001179 42 m2
68 68 Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity) i)For foundation Blocks of Tripod BI01010001010000000000000515BI0100001180 0.3 % m3
69 69 ii) For spout chamber BI01010001010000000000000515BI0100001181 5.7 % m3
70 70 Ordinary Cement Concrete (mix 1: 1.5 :3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS Codes. (Stack yard to site distance= 40 KM i)For foundation Blocks of Tripod BI01010001010000000000000515BI0100001182 0.52 m3
71 71 Ordinary Cement concrete (1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering, reinforcement, if any, in ground floor as per relevant IS code. a) Pakur Variety (Stack yard to site distance= 40 KM) i)For foundation Blocks of Tripod BI01010001010000000000000515BI0100001183 1.03 m3
72 72 ii) For spout chambers BI01010001010000000000000515BI0100001184 4.45 m3
73 73 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor)\n(When the height of a particular floor is more than 4 m. the equivalent floor ht. shall be taken as 4 m. and extra for works beyond the initial 4 m. ht. shall be allowed under 16 (c) for every 4 m. or part thereof.)\n (a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge. i)For foundation Blocks of Tripod BI01010001010000000000000515BI0100001185 5.2 m2
74 74 ii) For spout chamber BI01010001010000000000000515BI0100001186 12.75 m2
75 75 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.\n(a) For works in foundation, basement and upto roof of ground floor / upto 4m.\n (i) Tor steel/Mild steel i)For foundation Blocks of Tripod BI01010001010000000000000515BI0100001187 0.08 MT
76 76 Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete in foundation and plinth. (a) In foundation & plinth BI01010001010000000000000515BI0100001188 10 m3
77 77 12.5 cm. thick 1st class brickwork in cement mortar (1 : 4) in ground floor including, scaffolding, racking out joints etc. complete. BI01010001010000000000000515BI0100001189 8.1 m2
78 78 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints, including throating, nosing and drip course, scaffolding/staging where necessary (ground floor) excluding cost of chipping over concrete surface.(ii) with (1:4) cement mortar, \n (b) 15 mm. thick plaster BI01010001010000000000000515BI0100001190 113 m2
79 79 Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.\nNOTE : Cement 0.152 cu.m. per 100 sq.m. BI01010001010000000000000515BI0100001191 113 m2
80 80 Labour charges for fitting and fixing and laying , where necessary of fowlling M.S/G.I. /E.R.W pipes and accessories (to be supplied deparmentally) including transportation of the same cutting, threading, jointing & making leak proof threaded / flanged joints at site, by using scoket/ rubber insertion, nuts and bolts etc., maintaing the proper alignment and level / all complete / as per direction of E-I-C. (i)(a) 150 mm. dia. ERW pipe. BI01010001010000000000000515BI0100001192 48 m
81 81 (i)(b) 100 mm dia. NB ERW/MS Pipes BI01010001010000000000000515BI0100001193 24 m
82 82 Erection, fitting, fixing of set of M S Tripod inlet and outlet pipe fittings for MDTW / MINI RLI Scheme.(Rate inclusive of transportation from departmental store to work site). BI01010001010000000000000515BI0100001194 1 Each Set
83 83 Priming one coat on steel or other metal surface with synthetic oil\nbound primer of approved quality including smoothening surfaces by sand papering etc\n BI01010001010000000000000515BI0100001195 20 m2
84 84 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :\n (b) On steel or other metal surface :\nWith super gloss (hi-gloss) -\n (iv) Two coats (with any shade except white) BI01010001010000000000000515BI0100001196 20 m2
85 85 Labour charges for fitting, fixing110 mm. Dia. Alfa-AIfa valve with 140mm. dia. P.V.C. riser pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C. End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete. BI01010001010000000000000515BI0100001197 9 Each
86 86 Labour charges for fitting, fixing (150 x 140) mm dia M S reducer with 110 mm dia UPVC pipe with the help of FTP (flanged tail piece) by joining the PVC end of the tail piece and 110 mm dia UPVC pipe with coupler and flanged end of tail piece and expander with rubber insertion, nuts and bolts etc. complete. (Rate inclusive of transportation from departmental store to work site). BI01010001010000000000000515BI0100001198 2 Each
87 87 Labour charges for fitting & fixing of 150 & 100 mm dia Sluice Valve. BI01010001010000000000000515BI0100001199 4 Each
88 88 Supplying, fitting and fixing including transportation of sign board for identifing the exact location of MINI RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include one materials and labour complete as per drawing and direction of EIC. BI01010001010000000000000515BI0100001200 1 LS
89 89 Suppling 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house. BI01010001010000000000000515BI0100001201 1 LS
90 90 c)Transportation of Diesel Engine pumping set / Electro-Motor pumping set for Mini R.L.I. of any make/brand with necessary fixtures viz. M.S. bend, M.S. Pipes, Rubber Hose Pipe, Manifold, Surge tank, foot valve, non-return valve, tail piece, hose clamp, sluice valve, priming chamber etc. over Pucca/Kancha road from Sub-Divisional Store to worksite excluding loading at the lifting point and unloading at the delivery point.B. For Electro Motor\n(a) Carriage by Road :\n(i) Distance upto 50 km. BI01010001010000000000000515BI0100001202 2 Set
91 91 Installation of Diesel Engine /Electro-Motor pumping set of any make / brand and for RLI scheme on pump foundation over SAL sleeper (to be supplied departmentally) by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 90° M S priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-charge. (Pump set and all accessories will be supplied departmentally). c) For Mini R.L.I. Scheme. BI01010001010000000000000515BI0100001203 2 Set
92 92 b) Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Deasel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in-Charge.\niii) For Mini R.L.I. BI01010001010000000000000515BI0100001204 1 Each set
93 93 ELECTRIC WIRING(1? Wiring For Lighting Load ) Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 2 Way BI01010001010000000000000515BI0100001205 1 Each
94 94 Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection Lagrand Double Pole 32 A BI01010001010000000000000515BI0100001206 1 Each
95 95 Wiring from MCB SS Enclosure to Busbar by the following size of 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Brand Approved by EIC) in 25 mm PVC casing-capping (Precision make) including necessary PVC clips fittings etc. as required. . 2X 22/0.3 (1.5 Sq mm) + 1 X 22/0.3(1.5 Sq mm) ECC BI01010001010000000000000515BI0100001207 3 RM
96 96 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips fittings etc. to light/fan point with piano key type switch (Anchor Make ) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necessary connections and making earthing attachment and mending good damages to building works. [PVC casing capping and Switch board both on surface] (b) Avg Run 6 run meter \n BI01010001010000000000000515BI0100001208 4 Point
97 97 Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips fittings etc. with S & F 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on PVC switch board on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] (a) Onboard BI01010001010000000000000515BI0100001209 1 Point
98 98 Supplying and fixing of 6 -32 Amp Single Pole MCB on Switch Board as per direction of E.I.C. BI01010001010000000000000515BI0100001210 1 Each
99 99 Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. BI01010001010000000000000515BI0100001211 2 each
100 100 Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set. BI01010001010000000000000515BI0100001212 2 each
101 101 3 ? Wiring ( Motor Wiring )Fixing only of 63 A, 415 V sheet steel TPN main switch on Angle iron Frame on wall . BI01010001010000000000000515BI0100001213 1 each
102 102 Fixing only of 4 Bars 63 A, 415 V M.S. sheet metal busbar chamber on angle iron frame on wall . BI01010001010000000000000515BI0100001214 1 each
103 103 Fixing only of 32 A, 415 V sheet steel TP main switch on Angle iron Frame on wall. BI01010001010000000000000515BI0100001215 2 each
104 104 Fixing only of Star Delta starter (for 7.5 HP motor contol) on angle iron frame on wall with nut and bolts and making necessary connection with electrical cable.. BI01010001010000000000000515BI0100001216 2 each
105 105 Supply of 4 inch Round Projection type Ammeter (range 0-50/100 Amps), MIAC, Accuracy within +1.5% and confirming to IS : 1248/1968. BI01010001010000000000000515BI0100001217 2 Each
106 106 Supply of 4 inch Round Projection type Voltmeter (0-500 Volts), MI AC , Accuracy within +1.5% and confirming to IS : 1248/1968. BI01010001010000000000000515BI0100001218 3 Each
107 107 Fixing only Voltmeter/Ammeter with screws & other fixing materials incl.making necessary holes and connections. BI01010001010000000000000515BI0100001219 5 each
108 108 Fixing and connection Capacitor bank with suitable cable and others necessary materials to the system on a suitable place as per direction of E.I.C.. BI01010001010000000000000515BI0100001220 2 each
109 109 Meter loop connection with 1.1 K.V. Gr. 3½ core, 25 Sqmm P.V.C./ XLPE insulated & sheathed and armoured Aluminium Cable from Meter to incomming TPN Main Switch / Terminal. (Brand: Gloster/Havells/Finolex) . BI01010001010000000000000515BI0100001221 2 RM
110 110 Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to IEE regulation and as per direction of EIC.(Brand: Gloster/Havells/Finolex)(i) 4C x 10 sqmm Copper cable conforming to IS 694 [63 A TPN switch to Bus-bar] BI01010001010000000000000515BI0100001222 1.5 RM
111 111 (ii) 3C X 4 sqmm copper cable conforming to IS 694 [Busbar to 32 A, TP Main switch and 32 A TP switch to Motor starter] BI01010001010000000000000515BI0100001223 3 RM
112 112 (iii) 2 X 3C X 2.5 sqmm copper cable conforming to IS 694 in 25 mm GI conduit (ISI-Medium quality)[ Star-Delta Motor starter to Motor] BI01010001010000000000000515BI0100001224 10 RM
113 113 Suppling & fixing of EI danger Board 20 cm x 30 cm (8"x12") in two distinguishing position . As per IEE regulation. . BI01010001010000000000000515BI0100001225 2 each
114 114 Suppling fitting & fixing of shock treatment chart in a wooden frame. BI01010001010000000000000515BI0100001226 1 each
115 115 Earthing with 50 mm dia Galvanized iron pipe 3.64 mm thick X 3.04 mtr. long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm dia X 80 mm long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. below the ground level. By ISI-Medium G.I. Pipe. BI01010001010000000000000515BI0100001227 2 set
116 116 Supplying and fixing earth bar of galvanized (hot dip) M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes on busbar complete with G.I. bolts, nuts, washers spacing insulators etc. as required for tapping. BI01010001010000000000000515BI0100001228 0.5 Meter
117 117 Connecting the equipments to earth busbar including supplying and fixing G.I. (hot dip) Wire on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages. By Solid 8 S.W.G. GI Wire . BI01010001010000000000000515BI0100001229 40 Meter
118 118 Insulation testing of internal wiring of Pump House/Kiosk Boxincluding wiring of electric Motor & other ancilary equipments by means of Megger . BI01010001010000000000000515BI0100001230 1 Total System
119 119 Placing and positioning the Centrifugal pump motor set on the pump base/pump house floor, alligning properly with necessary packing and fixing the set with holding down nuts and washer including cutting holes of requisite size in the floor / base, grouting the bolts and mending good all damages- complete as per direction of Engineer-in-Charge. BI01010001010000000000000515BI0100001231 2 Each Set
120 120 Solar Module: Supply , transport , installation and commissioning of ISI marked as per IS 14286 and IEC 61853(1), 61730(1&2), 61710 certified Solar Module of Multicrystaline/Monocrystalline/ Monocrystalline PERC/bifacial cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2/4.0 mm tempered glass , framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied.a) For 5 HP Off-grid Solar Water Pumping System with Multicrystalline SPV modules - 5525 Wp. BI01010001010000000000000515BI0100001232 11050 Wp
121 121 Module Mounting Structure ( For 2HP, 3HP and 5HP Solar Water Pumping System): Supply , transportation & installation of G.I manual tracking structure made of MS hollow sections, pipes, plates, angles etc as per IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Module as per drawing and specification of MNRE . The steel structure is to be protected with minimum 80 micron galvanisation(hot dip) and provided with dual axis manual tracking arrangement three times in a day and seasonal tilting are to be regulated to face the sun optimally.The weight of the Module Mounting Structure holding 4 Modules should not be less than 195Kgs, holding 6 Modules should not be less than 210 Kg and holding 8 Modules should not be less than 245 Kg. (214.13Kg for 6 module structure) BI01010001010000000000000515BI0100001233 1284.8 Kg.
122 122 Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking SPV Module structure as per approved drawing.a) For 4/6 module structure BI01010001010000000000000515BI0100001234 6 Each
123 123 Power conditioning unit with IP54 enclosure :Supply , transport , installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard , safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine.condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc . The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol . It should also monitor and save total run time, total water pumped etc . There should be provision for interfacing GPRS based data transmission.c) For 5 HP capacity Pump-motor set BI01010001010000000000000515BI0100001235 2 Set
124 124 Cable and Accessories :\nSupplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc.\ni. 4.0 Sq mm single core multi studs - 10 Mtrs (Minimum)\nii. 6.0 Sq mm single core multi struds -5 Mtrs (Minimum)\niii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etcc) For 5 HP per structure BI01010001010000000000000515BI0100001236 6 Each
125 125 Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:\n By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.\n BI01010001010000000000000515BI0100001237 6 Each Set
126 126 Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of 8 swg on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages BI01010001010000000000000515BI0100001238 40 m
127 127 a) Lighting System at Scheme: (with lighting Pole) :\nDusk to dawn lighting arrangement of at 4 mts height with 75 mm x 50 mm G.I. pipe with 12 V, 40Ah 2-in-1 Lithium ion/ Ferro- Phosphate battery with in-built 11 watt LED lamp , 50 Wp solar panel to cover the scheme area. The lighting system should be warranted for 5years from the date of installation. BI01010001010000000000000515BI0100001239 1 Each
128 128 Lightning protection (Pole mounted): Lightning protection with 3" X 1.5" G.I pipe of (6+1) mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top . Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts, including connection to earth electrodes with 25 X 6mm G.I strip. (Provision of one lightning protection for each scheme as per drawing) BI01010001010000000000000515BI0100001240 2 Each
129 129 Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:-c) 5 HP ISI marked 3 phase 415 V Pump-Motor set having discharge at required head as below:-c) 5 HP ISI marked 3 phase 415 V Pump-Motor set having discharge at required head as below:-i) Monoblock Surface Pump-motor set ISI marked as per IS: 9079 for mini RLI scheme / PDW with discharge of 13.8 Lps at 18 mts. total head with 100 mm dia. reinforced PVC suction pipe and delivery pipe, foot valve, nipple, priming bend Cable and all other required accessories to complete connection of suction and delivery side . BI01010001010000000000000515BI0100001241 2 Each
130 130 Testing and commissioning of scheme after completion of all work BI01010001010000000000000515BI0100001242 2 Item
131 131 Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time) c) For 5 HP both for Submersible & Surface pump Note:\nTotal comprehensive maintenance charge is to be withheld in addition to Securirty Deposit . Security Deposit will be released after expiry of warranty period of 1 year & Comprehensive maintenance charges will be released @ Rs.0.75 per Wp per year at the end of each maintenance period i.e.at the end of 2nd year, 3rd year, 4th year, 5th year. In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited BI01010001010000000000000515BI0100001243 11050 Wp
132 132 Insurance @ 2% for Item No. 1, 4, 8a/8b, and 10 for a period of 5 years. Note:2\nIst year's Insurance charge is to be paid on production of Original Receipt of premium payment. Remaining 4 years Insurance payment is to be withheld which will be released during 2nd, 3rd , 4th & 5th year on production of Original Receipt of premium payment. BI01010001010000000000000515BI0100001244 2 Item
133 133 Supplying fitting fixing including transportation of1 mtr x 0.6 m x 24 swg MS board contaning The name of Scheme and details of Scheme as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the pipe will be grouted in 1:2:4 CC on single brick flat soling BI01010001010000000000000515BI0100001245 1 LS
134 134 Supply fitting and fixing of Hot dip Galvanised ( min 80 micron) / Powder Coat painted M.S Kiosk Box / Stainless Steel Kiosk of SS304 of 710(L) X 410(W) X 740(H) and total height with legs is 1670mm for mounting of motor-pump set including transportation, grouting in Cement Concrete as shown in drawing. BI01010001010000000000000515BI0100001246 2 item
135 135 Add 4% Extra for WATER TRANSMISSION ARRANGEMENT ON (Sl No.60-92), Except Earth Work In Excavation & Fillings ( Sl No- 60,61,62&63) BI01010001010000000000000515BI0100001247 1 L.S.
136 136 Add GST @12% ON (Sl No.60-134,Except Sl No.120 &123 ) BI01010001010000000000000515BI0100001248 1 L.S.
137 137 Add GST @5% For (Sl No.120 &123) BI01010001010000000000000515BI0100001249 1 L.S.
138 138 Add labour welfare cess @ 1% on Total(Sl No.-60-134) with GST BI01010001010000000000000515BI0100001250 1 L.S.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail