Municipal Corporation-MC has published Laying Sw Pipe For Sewerage System To Fix The Clogging Of Machine Holes And Pipe Near House No . 3055 To 3080 At Sector 35 D Chandigarh Under The Jurisdiction Of Sde M . C . P . H Sub Division No . 18 Chandigarh . . Submission Date for this Tender is 27-01-2021. Sewerage Construction Tenders in Chandigarh Chandigarh. Bidders can get complete Tender details and download the document.
Name of Work : "LAYING SW PIPE FOR SEWERAGE SYSTEM TO FIX THE CLOGGING OF MACHINE HOLES AND PIPE NEAR HOUSE NO.3055 TO 3080 AT SECTOR 35-D, CHANDIGARH UNDER THE JURISDICTION OF SDE, M.C.P.H SUB DIVISION NO.18, CHANDIGARH (CH.TO:- A/MTC. OF SEWERAGE SYSTEM)". Approx. Amount: Rs.2,95,025/-; Earnest Money: Rs.5,910/- ; Time Limit: 01 Month | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m . All kinds of soil. (DSR No. 2.8.1) | BI01010001010000000000000515BI0100001113 | 121.19 | P.Cum |
2 | 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift from 1.50 m to 3.00 m depth including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (NSI) | BI01010001010000000000000515BI0100001114 | 47.76 | P.Cum |
3 | 3 | Providing services of excavator JCB complete in all respect to the entire satisfaction of EIC. (NSI) | BI01010001010000000000000515BI0100001115 | 4 | P.hrs. |
4 | 4 | Carriage of material by Mechanical Transport including loading unloading and stacking -Earth up to 2 km. (DSR No. 1.1.2) | BI01010001010000000000000515BI0100001116 | 101.32 | P.Cum |
5 | 5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar(DSR No15.7.4) | BI01010001010000000000000515BI0100001117 | 5.85 | P.Cum |
6 | 6 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR No. 15.3) | BI01010001010000000000000515BI0100001118 | 1.96 | P.Cum |
7 | 7 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter (DSR No. 19.1.3) | BI01010001010000000000000515BI0100001120 | 45.73 | P.Mtr. |
8 | 8 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 200 mm diameter S.W. pipe (DSR No. 19.2.3) | BI01010001010000000000000515BI0100001119 | 45.73 | P.Mtr. |
9 | 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). (DSR No. 4.1.10) | BI01010001010000000000000515BI0100001121 | 2.97 | P. Cum |
10 | 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR No. 6.1.1) | BI01010001010000000000000515BI0100001122 | 13.61 | P. Cum |
11 | 11 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand). (DSR No. 13.7.2) | BI01010001010000000000000515BI0100001123 | 31.21 | P. Sqm |
12 | 12 | Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform. (DSR No. 5.9.3) | BI01010001010000000000000515BI0100001124 | 8.73 | P.Sqm |
13 | 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). (DSR No. 5.3) | BI01010001010000000000000515BI0100001125 | 3.52 | P.Cum |
14 | 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR No. 5.22.6) | BI01010001010000000000000515BI0100001126 | 317 | P. Kg. |
15 | 15 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter (DSR No. 19.21.1) | BI01010001010000000000000515BI0100001127 | 1 | Each |
16 | 16 | Making plug in the existing running sewer line with wooden sleepers fixed with MS angle iron and GI pipe support all other contingent material required for the job to stop the flow of sewerage in downstream side the CBD : 100 to 200 mm diameter R.C.C. Pipe (NSI) | BI01010001010000000000000515BI0100001128 | 1 | Each |
17 | 17 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality H D - 20 Circular shape 560 mm internal diameter (DSR no. 19.19.3.1) | BI01010001010000000000000515BI0100001129 | 3 | Each |
18 | 18 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. (DSR No. 19.16) | BI01010001010000000000000515BI0100001130 | 18 | Each |
19 | 19 | Extra for cutting through metalled roads and their foundations including sorting and screening and stacking the stone metal at site of work to the satisfication of EIC. (NSI) | BI01010001010000000000000515BI0100001131 | 50 | P.Sqm |
20 | 20 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (NSI) | BI01010001010000000000000515BI0100001132 | 46 | P.Cum |
21 | 21 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (DSR No.2.25) | BI01010001010000000000000515BI0100001133 | 67.57 | P.Cum |
22 | 22 | Credit of old Bricks | BI01010001010000000000000515BI0100001134 | 1685 | Each |
23 | 23 | Credit against old Steel | BI01010001010000000000000515BI0100001135 | 156.8 | P.Kg |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail