Improvement/Replacement Of Joinery At Officers Living In Block , Improvement/ Replacement Of Sanitary Fitting At Building No P-57 ( A ) And Certain Flooring Work At Officers Mess At Af Stn Bkt, GE (AF) BUT-Uttar Pradesh

Military Engineer Services-MES has published Improvement/Replacement Of Joinery At Officers Living In Block , Improvement/ Replacement Of Sanitary Fitting At Building No P-57 ( A ) And Certain Flooring Work At Officers Mess At Af Stn Bkt. Submission Date for this Tender is 06-02-2021. Civil Work Tenders in GE (AF) BUT Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26635467
Improvement/Replacement Of Joinery At Officers Living In Block , Improvement/ Replacement Of Sanitary Fitting At Building No P-57 ( A ) And Certain Flooring Work At Officers Mess At Af Stn Bkt
Open Tender
Indian
Uttar Pradesh
GE (AF) BUT
06-02-2021

Tender Details

Improvement / Replacement Of Joinery At Officers Living In Block , Improvement / Replacement Of Sanitary Fitting At Building No P-57 ( A ) And Certain Flooring Work At Officers Mess At Af Stn Bkt

Key Value

Document Fees
INR 500 /-
EMD
INR 38700.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Improvement/Replacement of joinery at Officers living in block, improvement/Replacement of sanitary fitting at building No P-57 (A) & certain flooring work at officers mess at AF STN BKT
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Dismantling of floor, hearth and wall tilling incl mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises as directed by the Engr-in-Charge 250 Sqm
2 2 M&L Vitrified Ceramic tiles ( square / rectangular ) double charged light shed, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick screed bed or bedding layers in CM 1:6. all as specified and directed. Make-Kajaria/Somany/Johnson 80 Sqm
3 3 M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as directed. 1.5 Sqm
4 4 M&L Kota stone slab 20 to 25mm thick in floor laid over & including 15mm thick screed bed in CM (1:6) & jointed in grey cement slurry mixed with pigment to match the shade of slab including rubbing & polishing complete all as specified & directed. 12 Sqm
5 5 M&L kota stone slab 20-25mm thick in skirting or in vertical surface laid over & including 10mm thick rendering in CM (1:6) & joint in grey cement with pigment to match the shade of slab including rubbing & polishing complete all as specified & directed. 2 Sqm
6 6 M&L for grinding of existing old surface/cutting and treating the surface with beeswax polish complete all as specified & directed. 50 Sqm
7 7 Taking down cement plaster including racking out joints, hacking for key, scrubbing down with water etc on walls and ceiling. 180 Sqm
8 8 Demolition of brick work or stone/boulder masonary built in cement mortar of any specification and in any position complete all as specified. 5 Cum
9 9 M&L rendering 15mm thick in cement mortar (1:4) on brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified. 110 Sqm
10 10 M&L 15mm thick rendering in cement mortar (1:6) on brick wall or concrete surfaces, finished even and smooth without using extra cement complete all as directed. 30 Sqm
11 11 M&L for brick work with sub class "B" brick (using old size bricks)straight or curved on plain exc 6m mean radious built in CM 1:4 complete all as specified and directed. 5 Cum
12 12 M&L for preparing newly plastered surfaces of walls by brooming down and applying two coats of Acrylic weather proof exterior paint over one coat of primer over one coat of cement base exterior putty on plastered surfaces of walls etc. complete, all as specified and as directed. 110 Sqm
13 13 M&L complete removal of exixting surfaces of treatment & preparetion of plastered surfaces of wall applying two coat of weather proof exterior paint over one coat of alkali resistant primer and over one coat of cement base exterior putty on plastered surfaces of walls etc. complete all as specified and as directed. 125 Sqm
14 14 M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of wall care putty complete all as specified. 30 Sqm
15 15 M&L for preparation of old plastered surfaces of wall & applying one coat of distemper oil emulsion complete all as specified. 180 Sqm
16 16 M&L for preparation of old steel/iron surfaces & applying one coat synthetic enamel paint complete all as specified and directed. 45 Sqm
17 17 Taking down Chowkhats or frames with shutter (without taking off shutters from the frame) not exc. 1.5 Sqm each complete all as directed. 8 Each
18 18 Ditto all as per item No.17 above but exc. 1.5 sqm but not exc. 4 sqm each 16 Each
19 19 Taking down old shutters of any description not exc. 1.00 Sqm each complete all as directed. 8 Per leaf
20 20 Ditto all as per item No.19 above but exc. 1.00 sqm but not exc. 2 sqm each 4 Per leaf
21 21 S&F flush shutter, solid core construction, with black board core & plywood face panels, commerical type on both as per IS:1003 (part-I) kiln seasoned & chemically pressure treated complete all as directed. 6 Sqm
22 22 S & F for 32 mm thick 2nd class hardwood glazed & skeleton shutters, open rebated & prepared to receive glass, gauze etc.divided into squares with sash bars plain, chamfered or rounded mitred & rebated etc complete all as directed. 6 Sqm
23 23 S&F UPVC window 3 track size as reqd at site, wall thickness 1.2 mm +/- 0.25 mm, made out of extruded section plain UPVC section with window frame made out of rigid UPVC section cut at 4 corners & joint with plastic fusion welding with internal reinforce required, the shutter section made out of extruded rigid UPVC with internal reinforced with provn of 5 mm toughen glass and wiremesh as per requirement, the window shall be fixed to the wall using 65 x 100 mm long MS fasteners at suitable place provided for each vertical & harizontal member etc complete as specified & directed. 10 Sqm
24 24 S&F for 300mm long ,ordinary rat tail rod pattern spring including roller plate complete all as directed 4 Each
25 25 S&F for mild steel barrel tower bolt stove enamelled black with bright bolt 150mm long complete all as directed 16 Each
26 26 S&F for butt hinges 100mm long mild steel medium weight cold rolled complete all as directed 48 Each
27 27 S&F for mild steel sliding door bolt 300 mm long ,plate type ,stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate & two staple plate complete all as directed. 4 Each
28 28 S&F for 150 mm size mild steel pressed handle ovel type stove enamelled black complete all as directed. 16 Each
29 29 S&F for 150 mm long floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in door shutter complete all as directed. 8 Each
30 30 S&F for 0.36mm nominal dia of stainless steel wire cloth and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as directed. 12 Sqm
31 31 M&L for preparation of wood and wood based material over 10cm width or girth & applying two coat of synthetic enamel paint over a coat of primer complete all as directed. 24 Sqm
32 32 Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed. 85 Sqm
33 33 M & L for 4mm Non Asbestos fiber Cement building board of size (595x595)mm fixed in powder coated Anodised aluminium frame (snapgrid 600 mm x 600 mm) of standard section (a) aluminium wall angle 40mmx25mmx2mm, (b) aluminium main tee 36.5x25mmx1.40mm, (c) aluminium cross tee 23.5mm x 26.4mmx 1.40mm, (d) aluminium bracket at cross junction 25mm long (e) mild steel suspenderduly fabricated @ 605mm C/C 4mm dia & 600mm long average with the 4mm thick GI suspender in ceiling and applying on one coat of distemper oil emulsion complete all as directed. ( Make of building board- Everest/Armostrong, Make of Aluminum section- Hindalco/Jindal 85 Sqm
34 34 Dismantling plain or corrugated steel sheeting any gauge, including, Nanital or similar pattern roof coverings complete all as specified.. 56 Sqm
35 35 S&F pre-painted galvatume aluminium zinc coating GI based corrugated corrugatede steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /clading to fixed with self tapping screw as specified . 56 Sqm
36 36 S&F 0.63 mm thick with grade of Zinc coating 275, galvanised, mild steel sheeting, in ridge hips, vally gutters, drips and straight flashing (length and grith as fixed) complete all as directed. 4 Sqm
37 37 Surface excavation in soft/loose soil n exc 30cm deep and averaging 15cm deep and getting out. 265 Sqm
38 38 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified & directed. 39.75 Cum
39 39 M&L for machine pressed precast interlocking paver block PU coated (rubber moulding) any shape and size conforming to IS- 15658-2006 of 80mm thickness, M-40 Grade , with grey cement and pigment complete all as specified and directed. 265 Sqm
40 40 M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations filling, sub base and mass concrete filling, etc complete all as specified 26.5 Cum
41 41 M&L for sand filling under floor or in foundations including watering and consolidation 6.63 Cum
42 42 M&L for providing precast cement concrete 1:2:4 type B-1 (20mm graded stone aggaregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry),string courses, copings.kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match all as directed. 5.3 Cum
43 43 S&F coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over & including 15 mm thick screed bed or bedding layers in CM 1:6.complete all as specified & directed. Make- Kajaria/Somany/ Johnson 40 Sqm
44 44 S&F coloured Glazed ceramic tiles 300 x 450 x 7 mm thick, on vertical surfaces such as skirting, dado and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over & including 10 mm thick rendering in CM 1:4.complete all as specified & directed 120 Sqm
45 45 Taking up or down 15mm steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified & directed 12 RM
46 46 Taking up or down 20mm steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified & directed 12 RM
47 47 Taking up or down 25mm steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified & directed 30 RM
48 48 S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, fixed to walls and ceilings or laid in floors. complete all as specified & directed 12 RM
49 49 S & F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, fixed to walls and ceilings or laid in floors.complete all as specified & directed 12 RM
50 50 S & F 25 mm bore Galvanized Steel tubes, medium grade for flush pipes, fixed to walls and ceilings or laid in floors complete all as directed. 30 RM
51 51 S&F Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, incl all joints complete all as specified & directed 8 Each
52 52 S&F in repair PVC valve less, syphonic action type flushing cistern (10 ltrs capacity), low level, white with inlet ball valve float and handle including brackets complete all as specified & directed 8 Each
53 53 S & F in repair Vitreous China Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand. complete all as specified & directed 8 Each
54 54 Supply & Fixing 5 mm thick beveled edge mirror fixed to wooden plugs with chromium plated brass screws and cup washers complete all as directed. Make- Atul/Modi 8 Each
55 55 S & F in repair 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.complete all as specified & directed 24 Each
56 56 S & F in repair 15 mm bore center hole wash basin mixture, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe. 8 Each
57 57 S & F in repair Fancy type chromium plated with long shank and cup (Concealed type) 15 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as directed. 8 Each
58 58 S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches.complete all as specified & directed 24 RM
59 59 S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed 8 Each
60 60 S&F 110 mm dia bore PVC (SWR) bends with oval access doors complete all as specified & directed 24 Each
61 61 S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified & directed 8 Each
62 62 S & F PVC (SWR) floor trap of 75 mm outlet plain with grating including jointing with solvent cement. complete all as specified & directed 8 Each
63 63 Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 100mm dia pipe.complete all as specified & directed 8 Each
64 64 S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches.complete all as specified & directed 24 RM
65 65 M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 100 mm bore.complete all as specified & directed 24 RM
66 66 S & F 25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified & directed 8 Each
67 67 S&F 25 mm dia ball brass valve, high pressure with polythelene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as directed. 8 Each
68 68 S&F rotational moulded three layerd polyethylene water storage tanks (cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I complete all as specified & directed 8 Each
69 69 M&L 20mm thick Granite (of any type) tiles machine cut in skirting/dado laid over & including CM 1:4 cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing all as directed 2 Sqm
70 70 S&F for factory made solid panel PVC door shutter 30mm thick(style) consisting of frame made out of M.S tubes for top&bottom rails, MS frame shall be covered with heat moulded plain colour PCV "C" channel having a pvc sheet strip of 20mm width struck inside with solvent cement for stile and plain colour PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottem rail panelling of plain colour PVC sheet to be fitted in the MS frame welde / sealed to the stile and rails with suitable PVC sheet beading and jointed together with solvent cement to frame at site as per specificcation and drawing incl fixing of aluminium mongry ( two 200mm towe bolt two 150mm handle) fixed as required complete all as specified & directed 12.6 Sqm
71 71 S&F for Solid PVC Door frame of Size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S sqeuare tube,complete all as specified & directed 42 RM
72 72 S&F for 150mm long aluminium ,anodised barrel tower bolt of extruded section complete all as specified & directed 16 Each
73 73 M&L for rendering 10mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement.complete all as specified & directed 40 Sqm
74 74 Dismanthing water tank & removing to store of capacity exc 250 ltr & n.exc 500 ltr 5 Each
75 75 Disconnecting existing tanks, setting aside (or lowering if required) for repair, cleaning etc & hoisting if required, reconnecting & refixing in position (cleaning, repairing etc measured & paid seperately) of size 500 ltr capacity PVC tank as directed. 3 Each
76 76 M&L for mild steel TMT bar 10 mm dia & over cut to length, bent to shape required, including cranking, bending spirally for hooping for cals, hooking ends & binding with mild steel wire (annealed) not less than 09. mm dia or securing with clips all as directed. 80 Kg
77 77 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fitting and fixture and such as as switches, sockets ceiling rose,pendent holders,regulators,light fittings any type removing materials to store in safe custody or for credite etc, and making good the disturbed surface of walls and floors etc as directed. 138 Per point
78 78 Taking down old and unsrevicable sheet metal enclosure , switch fuse unit , distribution board any type /way / capacity including fuses,MCB's , insulator etc complete after removing all connection and making good the disturbed surface all as directed. 13 Each
79 79 M&L for point wiring with two single core PVC insulated & PVC unsheathed FRLS multi stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade in and including making good the distrubed surfaces of wall with colour washing/ distemparing the surface to match the existing, in non metallic rigid PVC conduit medium grade 2 mm thick minium 20 mm dia with all accessories, mounting all the surface of wall/ ceiling/roof etc with sutaible size of 1 to 8 module metal flush boxes and including modulea front cover colour plate & back plate for mounting modular type switch/socket/Fan regulator etc encluding provision of one single core PVC insulated & unsheathed multi-stranded copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete with MS rectangular type box not less than 1.6 mm thick of suitalbe size duly inside & out side painted with two coats of synthetic enamel paint over one cost of red oxide primer & with top cover 3 mm thick of plastic laminated shats of reqd colour for mounting the switch socket etc complete as specified for One light point controlled by one 5 Amps modular switch 240V one way complete.\nMake of Cable :- RR Kable/Finolex/RPG (Asian). Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex 60 Per point
80 80 Ditto all as per item No 79 here in before but one bell /buzzer point controlled by one 5 Amp modular switch 240V one way complete 6 Per point
81 81 One selling/ Exhaust Fan point controlled by one 5 Amps modular switch 240V one way complete. 12 Per point
82 82 Ditto all as per item No 79 here in before but 3 pin/ 5 pin, 5 Amp socket outlet control by one 5 Amp modular switch on independed board. 30 Per point
83 83 Ditto all as per item No 79 here in before but 3 pin/ 5 pin, 5 Amp socket outlet control by one 5 Amp modular switch on same board. 12 Per point
84 84 Ditto all as per item No 79 here in before but using 2.5 sqmm, PVC insuleted, PVC unsheathed FRLS multi-stranded copper condutor for 3/5 Pin, 15 Amp modular socket outlet point on independed board. 18 Per point
85 85 S&F modular switch one way 6 Amps 1 module type , 240V. 114 Each
86 86 S&F modular socket 6/16 Amps 2/3 pin combined 2 module type complete. 42 Each
87 87 S&F modular switch socket combination 6 /16 Amps 2/3 pin combined 3 module type complete. 18 Each
88 88 S&F modular switch bell push flush, single pole one way, 5 Amp 230 Volt type 6 Amps 1 module complete. 6 Each
89 89 S&F bell AC 230 Volt, Dingdong type single pole complete. 6 Each
90 90 S&F ceiling rose surface backlite 65 x 20mm size three terminal, AC, 230 Volt complete. 36 Each
91 91 S&F LED tube light fitting box type decorative luminaire wall mounting of capacity 20 Watts with 1 Nos LED tube 20 Watts complete making all connection using PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit including as per site requirement and 2 Nos of round or square wooden / PVC bolck for fixing of FTL fitting complete all as per directed. 6 Each
92 92 S&F LED mirror light fitting of capacity 9 Watt wall mounted batten with polycarbonate housing with all fixing acessories complete all as specified and directed. 6 Each
93 93 S&F LED ultra slim panel ceiling light fitting 2'X2' of capacity 36 Watts complete making all connection using PVC insulated 3 core flexible cable from ceiling rose to fitting complete all as per directed. 24 Each
94 94 S&F LED bed light fitting of capacity 5 Watts including all fixing accessories complete all as per directed. 12 Each
95 95 S&F ceiling fan of size 1200 mm sweep with electronic fan regulator including all fixing acessories , BEE 5 star rated complete all as specified and directed. 6 Each
96 96 S&F exhaust fan of size 300 mm sweep with louver and shuter including all fixing acessories complete all as specified and directed. 6 Each
97 97 S&F storage vertical water heater geyser of capacity 25 ltrs , BEE 5 star rated including all fixing acessories complete all as specified and directed. 6 Each
98 98 M&L for submain wiring with two run of single core PVC insulated unsheathed FRLS multi stranded copper conductor cable of size 4 Sqmm 1100 volts grade and one run of PVC insulated unsheathed FRLS multi-stranded copper conductor cable of size 2.5 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic surface conduit of 25 mm dia on roof/wall/ceiling including making good the disturbed surfaces of wall etc complete all as directed by Engr-in-Charge \n(Note : Two run of single core cable 4 sqmm and one run of earth wire 2.5 sqmm will be measured as one length and conduit & its accessories is deemed to be included in the unit rate). Make of Cable :- RR Kable/Finolex/RPG (Asian)/L&T, Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex 145 RM
99 99 M&L in repair for submain wiring with two run of single core PVC insulated unsheathed FRLS multi stranded copper conductor cable of size 6 Sqmm 1100 volts grade and one run of PVC insulated unsheathed FRLS multi-stranded copper conductor cable of size 4 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic surface conduit of 25 mm dia on roof/wall/ceiling including making good the disturbed surfaces of wall etc complete all as directed by Engr-in-Charge \n(Note : Two run of single core cable 6 sqmm and one run of earth wire 4 sqmm will be measured as one length and conduit & its accessories is deemed to be included in the unit rate). Make of Cable :- RR Kable/Finolex/RPG (Asian)/L&T, Make of PVC conduit :- AKG/ Plaza/ Jindal / Finolex 220 RM
100 100 S&F for sheet metal enclosures with two pin and earth plug socket controlled including by one No. MCB 'B' curve, 10 KA, 20 Amps , 240 Volts grade, double pole type complete. 6 Each
101 101 S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 8 way, 240 Volts, sheet metal powder coated, IP 43 protection with 200 Amps rated bus bar for each phase, double door type complete all as specified and directed. 6 Each
102 102 S&F distribution board VTPN with provision of 160 Amps MCCB as incommer 12 way, 415 Volts, sheet metal powder coated, IP 43 protection with 250 Amps rated bus bar for each phase, double door type complete all as specified and directed. 1 Each
103 103 S&F MCB TPN 63 Amps, 415 Volts, rupturing capacity 10 KA."C" Series complete all as directed. 12 Each
104 104 S&F MCB SPN, 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series complete all as directed. 4 Each
105 105 S&F MCB SP, 5 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series complete all as directed. 36 Each
106 106 Earthing complete with galvanised steel earth plate electrode 60cm x 60cmx6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earthing point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 (using 20 mm graded stone aggragate) with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as specified & directed. \n( Note - (i)The rate includes for GI pipe protection, GI wire upto 7.5 m length (ii) Earthing shall be tested as specified in SSR clause 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (iii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge). 1 Each Set