Replacement Of Aluminium Wiring By Copper Wiring Including Switch Socket G . I . Modular Box In S . P . Jain Centre At Sdc, South Campus-Delhi

Delhi University has published Replacement Of Aluminium Wiring By Copper Wiring Including Switch Socket G . I . Modular Box In S . P . Jain Centre At Sdc. Submission Date for this Tender is 27-01-2021. Electrification Work Tenders in South Campus Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

26627775
Replacement Of Aluminium Wiring By Copper Wiring Including Switch Socket G . I . Modular Box In S . P . Jain Centre At Sdc
Open Tender
Indian
Delhi
South Campus
27-01-2021

Tender Details

Replacement Of Aluminium Wiring By Copper Wiring Including Switch Socket G . I . Modular Box In S . P . Jain Centre At Sdc

Key Value

Document Fees
INR 500 /-
EMD
INR 7717.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Replacement of aluminium wiring by copper wiring including switch socket G.I. modular box in S.P. Jain Centre at SDC
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. Group C BI01010001010000000000000515BI0100001113 135 point
2 2 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm BI01010001010000000000000515BI0100001114 1000 metre
3 3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sq. mm BI01010001010000000000000515BI0100001115 350 metre
4 4 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 4 sq. mm BI01010001010000000000000515BI0100001116 400 metre
5 5 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 6 sq. mm BI01010001010000000000000515BI0100001117 150 metre
6 6 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm BI01010001010000000000000515BI0100001118 300 metre
7 7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch BI01010001010000000000000515BI0100001119 165 each
8 8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch BI01010001010000000000000515BI0100001120 25 each
9 9 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet BI01010001010000000000000515BI0100001121 30 each
10 10 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet BI01010001010000000000000515BI0100001122 25 each
11 11 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001123 30 each
12 12 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm) BI01010001010000000000000515BI0100001124 50 each
13 13 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm) BI01010001010000000000000515BI0100001125 15 each
14 14 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm) BI01010001010000000000000515BI0100001126 15 each
15 15 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm) BI01010001010000000000000515BI0100001127 10 each
16 16 P/f tinny trip A.C. GI box with mnodular type complete with modular plate including 1 no 32 amps 'c' curve SPMCB and 1 no 25 amp 6 pin socket i/c connections as required. BI01010001010000000000000515BI0100001128 20 each
17 17 Dismantling existing switch, socket, sheet Aluminium wirings, TPDB, regulator, fittings, fans etc. required. BI01010001010000000000000515BI0100001129 1 Job
18 18 S/L/F 3 1/2 x 25 sqmm pvc insulated pvc sheathed, XLPE power cable of 1.1. KV grade as per latest I.S. code including laying/ fixing on terrace, wall inducing connections etc. as required. (Havells/Sky tone) BI01010001010000000000000515BI0100001130 200 metre
19 19 S/f 2x18 watts LED tube fittings i/c LED tube 2 nos direcrt on wall, ceiling on existing down rod i/c connections tc. as required. (4'- 0" long) BI01010001010000000000000515BI0100001131 35 Nos.
20 20 S/f 1x18 watts, 4’-0” long LED tube fittings including LED tube direct on wall ceiling on existing down rod i/c Connections. BI01010001010000000000000515BI0100001132 20 Nos.
21 21 P/f 1400 mm sweep high speed double ball bearing, three star rating ceiling fan without regulator i/c connections etc. as required. (Havells make) BI01010001010000000000000515BI0100001133 25 Nos.
22 22 Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 8 way (4 + 24), Double door BI01010001010000000000000515BI0100001134 2 Nos.
23 23 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole BI01010001010000000000000515BI0100001135 48 each
24 24 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps BI01010001010000000000000515BI0100001136 2 each