Repair/Maintenance Of Lt Panel , Feeder Pillars And Connected Items Of External Electric Supply At Old Amritsar Cantt, GE Amritsar-Punjab

Military Engineer Services-MES has published Repair/Maintenance Of Lt Panel , Feeder Pillars And Connected Items Of External Electric Supply At Old Amritsar Cantt. Submission Date for this Tender is 26-01-2021. Feeder Pillar Tenders in GE Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

26625414
Repair/Maintenance Of Lt Panel , Feeder Pillars And Connected Items Of External Electric Supply At Old Amritsar Cantt
Open Tender
Indian
Punjab
GE Amritsar
26-01-2021

Tender Details

Repair/Maintenance Of Lt Panel , Feeder Pillars And Connected Items Of External Electric Supply At Old Amritsar Cantt

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: Repair/replacement of LT Panel, feeder pillars and connected items of external electric supply at Old Amritsar Cantt
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply and fixing in repairs, installation, commissioning and testing CPRI approved factory made LT feeder pillar box , double door, outdoor ,FRONT& REAR OPENABLE type totally enclosed free pedestal mounting dust and vermin proof, weather proof made out of 1.65 mm thick stainless steel , 304 grade duly powder coated using 7 tank process as per IS: 8623 rated for short circuit rating of 50 KA ,base frame of 50mm x 50mm x 5mm,with hinges of stainless steel,slider door locks(front &rear ) ,door handles (front&rear) suitable for 415 Volts, 3 phase, 4 wire, 50 Hz, AC supply outdoor type complete with and including incoming and outgoing moulded case circuit breakers, aluminium bus bar including internal wiring with not less than PVC insulated unsheathed 2.5 Sqmm multi stranded copper conductor cable, bonding to earth interconnection complete as required and as approved from CPRI all as specified and directed : Note : Outer dimension of panel should be minimum width =2.0 mtr, Depth = 0.90 mtr, Height = 2.0 mtr hight\nIncoming\n(a) ACB of Cap 630 Amp, 4 pole, 50 KA, Icu = Ics = Icw with Icw rated for 1 sec , 415 volt, 50 Hz - 01 Nos, Manual Drawout type, micropressor release complete all as specified and directed. Make Legrand/Schneider/Siemens\nOut going\n(a) MCCB of Cap 400 Amp, 4pole, 36 KA,Microprocessor based,Icu = Ics = Icw 415 volt, 50 Hz MCCB - 01 Nos Make Legrand(DPX3) / Schneider(NSX) / Siemens(3VL)\n(b) MCCB of Cap 250 Amp, 4pole, 25 KA,Microprocessor based, Icu = Ics = Icw415 volt, 50 Hz MCCB - 03 Nos Make Legrand(DPX3) / Schneider(NSX) / Siemens(3VL)\n(c) Aluminium BUS BAR SUITABLE FOR 800 A ,SIZE 80mm*10mm (R Y B N) COVERED WITH HEAT SHRINKABLE COLOUR CODED SLEEVES\n(d) Digital LCD MULTIFUNCTIONAL METER,Class. 1 .0 ACCURACY DISPLAYING VOLTAGE ,CURRENT of all type of phase ,FREQUENCY complete with 3 CTs of suitable size -01 No, Make of multifunction meter :- AE/Risabh/Schneider\n(e) L E D indicating lamps (R, Y & B) PROTECTED WITH 2A SP MCB'S - 01 set of three lamps, Make of LED indicating lamps and MCB - Legrand/Schneider/Siemens\n(f) EARTHING STRIP OF SIZE 25mm*5mm OF ALUMINIUM RUNNING THROUGHOUT THE LENGTH OF THE SUBJECT L T PANEL 3 Each
2 2 Supply and fixing in repairs, installation, commissioning and testing CPRI approved factory made LT feeder pillar box , double door, outdoor ,FRONT& REAR OPENABLE type totally enclosed free pedestal mounting dust and vermin proof, weather proof made out of 1.65 mm thick stainless steel , 304 grade duly powder coated using 7 tank process as per IS: 8623 rated for short circuit rating of 36 KA ,base frame of 50mm x 50mm x 5mm,with hinges of stainless steel,slider door locks(front &rear ) ,door handles (front&rear) suitable for 415 Volts, 3 phase, 4 wire, 50 Hz, AC supply outdoor type complete with and including incoming and outgoing moulded case circuit breakers, aluminium bus bar including internal wiring with not less than PVC insulated unsheathed 2.5 Sqmm multi stranded copper conductor cable, bonding to earth interconnection complete as required and as approved from CPRI all as specified and directed : Note : Outer dimension of panel should be minimum width =1.50 mtr, Depth = 0.50 mtr, Hieght = 1.5 mtr hight\nIncoming\n(a) MCCB of Cap 400 Amp, 4pole, 36 KA,Microprocessor based,Icu = Ics = Icw 415 volt, 50 Hz MCCB - 01 Nos Make Legrand(DPX3) / Schneider(NSX) / Siemens(3VL)\nOut going\n(a) MCCB of Cap 250 Amp, 4pole, 36 KA,Microprocessor based,Icu = Ics = Icw 415 volt, 50 Hz MCCB - 02 Nos Make Legrand(DPX3) / Schneider(NSX) / Siemens(3VL)\n(b) MCCB of Cap 160 Amp, 4pole, 25 KA,Microprocessor based, Icu = Ics = Icw415 volt, 50 Hz MCCB - 02 Nos Make Legrand(DPX3) / Schneider(NSX) / Siemens(3VL)\n(b) MCCB of Cap 100 Amp, 4pole, 25 KA,Microprocessor based, Icu = Ics = Icw415 volt, 50 Hz MCCB - 02 Nos Make Legrand(DPX3) / Schneider(NSX) / Siemens(3VL)\n(c) Aluminium BUS BAR SUITABLE FOR 400 A ,SIZE 40mm*10mm (R Y B N) COVERED WITH HEAT SHRINKABLE COLOUR CODED SLEEVES\n(d) Digital LCD MULTIFUNCTIONAL METER,Class. 1 .0 ACCURACY DISPLAYING VOLTAGE ,CURRENT of all type of phase ,FREQUENCY complete with 3 CTs of suitable size -01 No, Make of multifunction meter :- AE/Risabh/Schneider\n(e) L E D indicating lamps (R, Y & B) PROTECTED WITH 2A SP MCB'S - 01 set of three lamps, Make of LED indicating lamps and MCB - Legrand/Schneider/Siemens\n(f) EARTHING STRIP OF SIZE 25mm*5mm OF ALUMINIUM RUNNING THROUGHOUT THE LENGTH OF THE SUBJECT L T PANEL 2 Each
3 3 Supply and fixing in repairs, installation, commissioning and testing CPRI approved factory made LT feeder pillar box , double door, outdoor ,FRONT& REAR OPENABLE type totally enclosed free pedestal mounting dust and vermin proof, weather proof made out of 1.65 mm thick stainless steel , 304 grade duly powder coated using 7 tank process as per IS: 8623 rated for short circuit rating of 36 KA ,base frame of 50mm x 50mm x 5mm,with hinges of stainless steel,slider door locks(front &rear ) ,door handles (front&rear) suitable for 415 Volts, 3 phase, 4 wire, 50 Hz, AC supply outdoor type complete with and including incoming and outgoing moulded case circuit breakers, aluminium bus bar including internal wiring with not less than PVC insulated unsheathed 2.5 Sqmm multi stranded copper conductor cable, bonding to earth interconnection complete as required and as approved from CPRI all as specified and directed : Note : Outer dimension of panel should be minimum width =1.50 mtr, Depth = 0.50 mtr, Hieght = 1.5 mtr hight\nIncoming\n(a) MCCB of Cap 250 Amp, 4pole, 36 KA,Microprocessor based,Icu = Ics = Icw 415 volt, 50 Hz MCCB - 01 Nos Make Legrand(DPX3) / Schneider(NSX) / Siemens(3VL)\nOut going\n(b) MCCB of Cap 160 Amp, 4pole, 25 KA,Microprocessor based, Icu = Ics = Icw415 volt, 50 Hz MCCB - 02 Nos Make Legrand(DPX3) / Schneider(NSX) / Siemens(3VL)\n(b) MCCB of Cap 100 Amp, 4pole, 25 KA,Microprocessor based, Icu = Ics = Icw415 volt, 50 Hz MCCB - 02 Nos Make Legrand(DPX3) / Schneider(NSX) / Siemens(3VL)\n(c) Aluminium BUS BAR SUITABLE FOR 400 A ,SIZE 40mm*10mm (R Y B N) COVERED WITH HEAT SHRINKABLE COLOUR CODED SLEEVES\n(d) Digital LCD MULTIFUNCTIONAL METER,Class. 1 .0 ACCURACY DISPLAYING VOLTAGE ,CURRENT of all type of phase ,FREQUENCY complete with 3 CTs of suitable size -01 No, Make of multifunction meter :- AE/Risabh/Schneider\n(e) L E D indicating lamps (R, Y & B) PROTECTED WITH 2A SP MCB'S - 01 set of three lamps, Make of LED indicating lamps and MCB - Legrand/Schneider/Siemens\n(f) EARTHING STRIP OF SIZE 25mm*5mm OF ALUMINIUM RUNNING THROUGHOUT THE LENGTH OF THE SUBJECT L T PANEL 4 Each
4 4 S&F bus bar enclosure 800 mm x 600 mm x 200 mm made out of 1.65 mm thick stainless steel , 304 grade duly powder coated using 7 tank process with and including 250 amp, 25 kA MCCB 4 pole, thermal magnetic based fitted in bus bar enclosure using 250 Amp rated bus bar, 25x10mm aluminium and RYB indication lamps duly protected by 2A SP MCB outdoor type welded to suitable size MS angle iron frame and embedded in PCC 1:2:4 type B-1 complete all as specified and directed.Height of the enclouser from ground level 0.5 meter Makeof MCCB Legrand(DPX3) / Schneider(NSX) /Siemens(3VL) Note for Item No 1 to 4: No authorisation from any manufacturer will be accepted, factory inspection will be carried out by the rep of the Accepting Officer before dispatch of the panels, Contractor shall make necessary arrangements for the visit of the representative of the Accepting officer and shall inform in advance to AO for the factory inspection. 6 Each
5 5 Material and labour for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 25 X 4 mm size by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 40 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.\nNote :- Required T&P for measurement of earth resistance shall be arranged by the contractor at his own cost. 15 Each
6 6 Supply and fixing in replacement with thermal magentic based of Cap 200 Amp, 4pole, 25 KA, with adjustable type , 415 volt grade including cutting and welding work for fixing of MCCB in existing panels any type and model. Make : Legrand (DPx3)/Schnieder (NSX)/Siemens (3VL) 2 Each
7 7 Replacement of MCCB of Cap 250 Amp, 4pole, 25 KA, with adjustable type thermal magnetic based, 415 volt grade including cutting and welding work for fixing of MCCB in existing panels any type and model. Make : Legrand (DPx3)/Schnieder (NSX)/Siemens (3VL) 2 Each
8 8 Replacement of MCCB of Cap 400 Amp, 4pole, 36 KA, with adjustable type thermal magnetic, 415 volt grade including cutting and welding work for fixing of MCCB in existing panels any type and model. Make : Legrand (DPx3)/Schnieder (NSX)/Siemens (3VL) 1 Each
9 9 Material and labour for scrapping/removing of old painted surfaces and preparation of surfaces of LT panels any type, size and make and repair of panels door by reolacement of broken hinges by nut/bolts, welding, griding etc all as per requirements at site including painting to be carried out using Ist quality synthetic enameled grey paint two coat with spray/brush and painting with two coat of black paint to angle/chanel stand of panel complete all as specified and directed. 25 Each
10 10 Supplying, laying 70 Sqmm 3.5 core LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and directed.Make Havells/Polycab/RR Kabel 200 RM
11 11 Supplying, laying 50 Sqmm 3.5 core LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and directed. Havells/Polycab/RR Kabel 200 RM
12 12 Supplying, laying 35 Sqmm 3.5 core LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and directed. Havells/Polycab/RR Kabel 250 RM
13 13 Supplying, laying 25 Sqmm 4 core LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and directed.Havells/Polycab/RR Kabel 250 RM
14 14 Supply and fixing 80 mm bore light grade galvanised iron tubing with all necessary GI fittings as in protection pipe of cable, fixed to pole or laid under floor / ground / under road crossings for protection of cable complete all as specified and directed. 20 RM
15 15 Material and labour for cleaning away all grass vegatation sapling shrubs bushesfrom under roots and tress not exceeding 30 cm grith and removing uptodistance of 50 mtrout the periphery of area under cleaness completeall as specified and directed.Note : T&P required for this job to be brought by the contractor. 2000 Sqm
16 16 Supply and spraying glyphosate 41% SL Glykol Herbicide to remove vegatation from E/M Installations complete all as specified and directed by Engr-in-Charge.Note : T&P required for this job to be brought by the contractor. 60 Litres
17 17 Material and labour for boring hole under road/path/floor etc for laying of XLPE cables any size and type all as specified and directed at site by Engineer-in-Charge. 15 RM
18 18 Supply and fix cable end jointing kit for LT XLPE grade cable for heat shrinkable complete with jointing materials and accessories suaitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm \n 10 Each
19 19 Supply and fix cable end jointing kit for LT XLPE grade cable for heat shrinkable complete with jointing materials and accessories suaitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 95 Sqmm \n 5 Each
20 20 Supply and fix cable end jointing kit for LT XLPE grade cable for heat shrinkable complete with jointing materials and accessories suaitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm \n 5 Each
21 21 Taking out existing gravels/hardcore material/brick bed from the bottom 66 KV substation completely and cleaning of complete substation including removal of weeds and cleaning with brush and spraying of anti grass chemical and screening the hardcore material and refilling the same at places all as specified and as directed by Engr-in-Charge 100 Cum
22 22 Material & labour for topping up hard core of broken stone of gauge size 20 mm deposited, spread and leveled in layers not exc.15 cms thick, each layer watered and rammed to a true surfaces complete all as specified and directed. 120 Cum
23 23 Material and labour for brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 metre mean radius, built in cement mortar 1:4 complete all as specified. 12 Cum
24 24 Material and labour for 10mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces and finishing the surface even and smooth without using extra cement complete all as specified.\n 10 Sq m
25 25 Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for laying of pipes and fittings, cables, HT / LT poles, stay assembly etc including forming bottom surfaces to required level and slope and getting out in hard / dense soil complete all as specified and directed. 160 Cum
26 26 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in hard / dense soil complete all as specified and directed. 85 Cum
27 27 Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. 75 Cum
28 28 Material & labour for sand filling in trenches for cable protection including necessary punning and consolidation as required complete all as specified and directed.NOTE:- Punned thickness only will be considering for payment. 60 Cum
29 29 Supply and laying burnt brick sub class 'B' modular size, for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed. 6.4 Per 1000\nNos
30 30 Surface Excavation not exceeding 30 cm deep and averaging 15 cm deep and geeting out the soil and throwing it at a distance not exceeding 50 metre as directed by Engineer-in-charge 180 Sq metre
31 31 Material and Labour for Hardcore of gauge n exec. 63 mm of broken bricks, deposited, spread and levelled in layers n exec. 15 cm thick, watered and rammed to a true surface 10 Cum
32 32 Material and labour for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for filling in foundation, filling in platforms of panels and mass concrete complete all as specified and directed 6 Cum