Military Engineer Services-MES has published Certain Repair To Electrically Operated Hanger Doors In 50 Sqn , T-7 And T-8 Hanger At Af Stn Agra . . Submission Date for this Tender is 30-01-2021. Door Tenders in GE (AF) TECH AREA AGRA Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work : CERTAIN REPAIRS TO ELECTRICALLY OPERATED HANGER DOORS IN 50 SQN , T-7 AND T-8 HANGERS AT AF STN AGRA. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Drawing No. | Quantity | Units | |
1 | 1 | Repair & maintenance of guide chanel & wheels (12 leaf/panel in each gate) including greasing/ oiling for smooth working/operation of gate complete all as specified and directed. Note : (i) Contractor rep shall visit every week and will check and carry out service and repair as required at site. (ii) Payment will be made only once during currency of contract even no of times gate repaired by the contractor. (iii) Parts required for replacement will be measured and paid saperately under respective item of BOQ. | 18 | EACH JOB | |
2 | 2 | S&F mild steel work such as stopper to guide chanel and other similar items including cutting, welding conforming to E-290 gde-E-165 complete all as specified and directed. | 150 | KG | |
3 | 3 | M&L for welding in repairs n exc 2.5cm in length and thickness of metal to be welded not exc 6mm complete all as specified and directed. | 50 | EACH | |
4 | 4 | S & F of driving units of gate including special geared motors with 3 Nos wheels (pully track), starter , wiring & electrical fitting/fixtures of existing capacity (from starter to motor) complete all as specified and directed. \nMake : Unidor TM or equivalent and approved by GE. | 3 | EACH JOB | |
5 | 5 | Repair/maintenance of top track trolly with 8 Nos horizontal axis rollers & 4 Nos vertical axis rollers including replacement of any part & hardware, bearings & steel rope for smooth working/operation of gate complete all as specified and directed. \nMake : Unidor TM or equivalant & approved by GE. | 3 | EACH JOB | |
6 | 6 | S&F in repair proxy switches M-30 of existing capacity complete all as specified and directed.\n | 50 | EACH | |
7 | 7 | S&F in repair indicator of gate of existing make/size/capacity complete all as specified and directed. | 14 | EACH | |
8 | 8 | Repair/maint including replacement of defective/wornout parts in control panel of gate including wiring & electrical fitting/fixture (from control panel to starter) complete all as specified and directed. | 10 | EACH JOB | |
9 | 9 | Repair & maintenance of guide chanel & wheels (4 leafs/panel in each gate) including greasing/oiling for smooth working/operation of gate complete all as specified and directed. Note : (i) Contractor rep shall visit every week and will check and carry out service and repair as required at site (ii) Payment will be made only once during currency of contract even no of times gate repaired by the contractor. (iii) Parts required for replacement will be measured and paid saperately under respective item of BOQ. | 2 | EACH JOB | |
10 | 10 | Replacement of driving units of gate including special geared motors with 3 Nos wheels (pully track) including starter , wiring & clectrical fitting/fixtures of existing capacity (from starter to motor) complete all as specified and directed. \nMake : Unidor TM or equivalent and approved by GE | 1 | EACH JOB | |
11 | 11 | Repair/maintenance of top track trolly with 12 Nos horizontal axis rollers & 4 Nos vertical axis rollers including replacement of any part ie. hardware, bearings & steel rope for smooth working/operation of gate complete all as specified and directed. \nMake : Unidor TM or equivalant & approved by GE. | 4 | EACH JOB | |
12 | 12 | Repair/replacement of unserviceable glass relay 24 V ,DC complete all as specified directed. | 30 | EACH | |
13 | 13 | S&F in repair MCB TPN 63 Amp 240V, C-series 10KA complete all as specified and directed. | 20 | EACH | |
14 | 14 | S&F in repair MCB SP 6 to 32 Amp 240 V 'C' Series 10 KA complete all as specified and directed. | 30 | EACH | |
15 | 15 | S&F in repair MCB DP 40-63 Amp 240 V 'C' Series 10 KA complete all as specified and directed. | 25 | EACH | |
16 | 16 | S&F in repair MCB TPN 32 Amp 240 V 'C' Series 10 KA complete all as specified and directed. | 10 | EACH | |
17 | 17 | Supply, lay, connecting and testing of XLPE, LT Cable of size 16 Sqmm 4 Core 1100 Volt PVC insulated of flexible cable with ennealed bare copper conductor complete all as specified and directed. | 440 | RM | |
18 | 18 | S&F in repair power supply AC to DC 220V/24V complete all as specified and directed. | 6 | EACH | |
19 | 19 | Supply, lay, connecting and testing of LT Cable of size 2 Sqmm 3 core, 1100 Volt PVC insulated heavy duty flexible cable with ennealed of bare conductor complete all as specified and directed. | 1500 | RM | |
20 | 20 | S&F controlled wire of size 1 Sqmm multi stranded copper conductor PVC insulated with colour code gray & black complete all as specified and directed. | 500 | RM | |
21 | 21 | S&F PVC connector with 2 Amp rating glass fuse complete all as specified and directed. | 20 | EACH | |
22 | 22 | S&F of digital type Amp meter 0 to 200 Amp size 96 x96 Sqmm built in selector switch with 03 Nos CT's complete all as specified and directed. | 8 | EACH | |
23 | 23 | S&F of digital type Volt meter 0 to 440 Volt line & phase voltaghe with built in selector switch size 96 x 96 Sqmm accuracy class -1 auxiliary supply 230V complete all as specified and directed. | 10 | EACH | |
24 | 24 | S&F in replacement of over load relay of capacity 5 to 12 Amp rating complete all as specified and directed. | 12 | EACH | |
25 | 25 | S&F in replacement of selector switch of 3 position with 3 NO + 2NC block complete all as specified and directed. | 5 | EACH | |
26 | 26 | S&F in replacement of cable carrier of existing size complete all as specified and directed. | 150 | EACH | |
27 | 27 | S&F in replacement of contactor 3 pole 220 Volt 16Amp with NC block complete all as specified and directed. | 30 | EACH | |
28 | 28 | Supply & refilling/ Top up of gear oil in special geared motors all as specified and directed. | 50 | LTR | |
29 | 29 | Repair & maintenance of guide chanel & wheels (8 leafs/panel in each gate) including greasing/oiling for smooth working/operation of each Gate complete all as specified and directed. \nNote : (i) Contractor rep shall visit every week and will check and carry out service and repair as required at site. (ii) Payment will be made only once during currency of contract even no of times gate repaired by the contractor. (iii) Parts required for replacement will be measured and paid saperately under respective item of BOQ. | 6 | EACH JOB | |
30 | 30 | M&L for Radium sheet with letters or numbers of any width & height , pasted on 1mm thick galvanised plain sheet of size 1.5mx1.5m with necessary fixing arrengement on hanger doors complete all as specified and directed | 30 | EACH JOB | |
31 | 31 | Providing and using of boom lift of hight up to 80 Ft alongwith fuel and operator for complete task for repairing of hanger gate and hangare maintenance lights, lighting arrestor etc at anywhere inside of airforce compus including servicing, checking of hanger gate including tightening and cleaning nut bolts and checking of electrical connected items complete all as specified & directed. Note:-(i) Contractor will be liable to arrange boom lift only after getting written orders from Engr-in-Charge each time for the minium period of one month i.e. 30 days. The date of arrival and returining back of boom lift will be mentioned in each order saperatly. If contractor fails to provide boom lift by stipulated date, then panel recovery of Rs. 3000.00 per day for the delayed period shall be effected from contractor due payment.\n(ii) Daily log sheets shall be maintained (which is mandatory requirement) for use of boom lift mentioning daily output. Log sheets shall be signed by contractor. JE concerned , Engineer-in-Charge and users.\n(iii) If the boom lift found kept ideal/ standby due to site condition /security reasons during the period, then only 50% of the quoted rate shall be payable to the contractor as standby charges and no other claim of contractor on this account shall be entertained.\n(iv) Contractor is required to submit documentary evidance for arrival/ returining back of boom lift (Work order site) while submitting his RAR /Final bill for payment. | 45 | EACH JOB |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail