Military Engineer Services-MES has published Provision Of Main Gate With Security Light And Guard Posts And Certain B/R Minor Works And Maintenance Work Under Age I Rd Avadi Provision Of Main Gate With Security Light And Guard Posts And Certain Br Minor Works And Maintenance Work Under Age I Rd Avad. Submission Date for this Tender is 22-01-2021. Security Lighting Tenders in AVADI Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

26624792
Provision Of Main Gate With Security Light And Guard Posts And Certain B/R Minor Works And Maintenance Work Under Age I Rd Avadi Provision Of Main Gate With Security Light And Guard Posts And Certain Br Minor Works And Maintenance Work Under Age I Rd Avad
Open Tender
Indian
Tamil Nadu
AVADI
22-01-2021

Tender Details

Provision Of Main Gate With Security Light And Guard Posts And Certain B/R Minor Works And Maintenance Work Under Age I Rd Avadi Provision Of Main Gate With Security Light And Guard Posts And Certain Br Minor Works And Maintenance Work Under Age I Rd Avadi

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 9.98 Lakhs /-

BOQ Items

NAME OF WORK : PROVISION OF MAIN GATE WITH SECURITY LIGHT AND GUARD POSTS AND CERTAIN B/R MINOR WORKS AND MAINTENANCE WORK UNDER AGE (I) R&D AVADI
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation of trenches, n.exc 1.5 wide and n.exc 1.5 in depth for fondation etc, or for shafts, well , cesspits, manholes pier holes etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft loose soil. 21 CUBIC METRE
2 2 M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and as directed by Engineer in charge. 3 CUBIC METRE
3 3 M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 all as specified and as directed by Engineer in charge. 31.3 CUBIC METRE
4 4 Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; verticle or to batter all as specified and as directed by Engineer in charge. 27.5 SQUARE METRE
5 5 Formwork to sides of pillars, posts, struts, piers,columns, and stanchions all as specified and as directed by Engineer in charge. 50 SQUARE METRE
6 6 Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc all as specified and as directed by Engineer in charge. 22 SQUARE METRE
7 7 Form work to chullah hoods, chajjas, troughs and similar items including edges all as specified and as directed by Engineer in charge. 7 SQUARE METRE
8 8 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) with fair finishes of surfaces all as specified and as directed by Engineer in charge. 20 SQUARE METRE
9 9 Form work to edge of concrete flats, treads, breaks in floors, window cills, concrete railing , opening in concrete wall, floors and roof n.exc 20cm wide and side of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide for fair finished surfaces all as specified and as directed by Engineer in charge. 3 RUNNING METRE
10 10 Mild steel bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips all as specified and as directed by Engineer in charge. 1015 KILOGRAM
11 11 Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified and as directed by Engineer in charge. 270 KILOGRAM
12 12 M&L for RCC 1:1.5:3, Nominal mix, using 20mm graded aggregate in Columns, pillars, piers, posts and struts all as specified and as directed by Engineer in charge. 5.7 CUBIC METRE
13 13 M&L for RCC 1:1.5:3, Nominal mix, using 20mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete all as specified and as directed. 5.4 CUBIC METRE
14 14 M&L for RCC 1:1.5:3, Nominal mix, using 20mm graded aggregate in Roof Beams, cantilevers, bressummers, lintels over 1.5m span all as specified and as directed by Engineer in charge. 2.5 CUBIC METRE
15 15 M&L for RCC 1:1.5:3, Nominal mix, using 20mm graded aggregate for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, chajja etc and the like all as specified and as directed. 2 CUBIC METRE
16 16 M&L for RCC 1:1.5:3,Nominal mix, using 20mm graded aggregate in chajjas all as specified and as directed by Engineer in charge. 0.4 CUBIC METRE
17 17 M&L for 5mm thick rendering in CM 1:3 on ceiling of roof slab and finished the surfaces even and smooth without using extra cement all as specified and as directed by Engineer in charge. 12 SQUARE METRE
18 18 M&L for 10mm thick cement plaster in CM 1:4 on concrete and brick masonry surface using water proofing compound @ 3% by the weight of cement and finished the surfaces even and smooth without using extra cement all all as specified and as directed by Engineer in charge. 100 SQUARE METRE
19 19 M&L for 10 mm thick cement plaster in CM 1:6 on concrete and brick masonry surface and finished the surfaces even and smooth without using extra cement all as specified and as directed by Engineer in charge. 60 SQUARE METRE
20 20 M & L three coat of white wash on new plastered surfaces on ceiling including preparation of new plastered surfaces all as specified and as directed by Engineer in charge. 12 SQUARE METRE
21 21 M&L for two coats of exterior acrylic based paint a coat of primer on new plastered surfaces including preparation of new plastered surfaces all as specified and as directed by Engineer in charge. 100 SQUARE METRE
22 22 M&L for two of coats distempering walls with distemper oil emulsion, white or tinted including preparation of new surfaces all as specified and as directed by Engr-in-Charge. 60 SQUARE METRE
23 23 M&L for Stone Hard core, broken to gauge n exc 63 mm all as specified and as directed by Engineer in charge. 4.62 CUBIC METRE
24 24 M&L 75mm thick cement concrete 1:3:6 type C-1 as in plinth protection, surface finished even and smooth without using extra cement all as specified and as directed by Engineer in charge. 46 SQUARE METRE
25 25 M & L PCC 1:4:8 type D2 (40mm graded aggregate) 75mm thick as in sub base of floors all as specified and as directed by Engineer in charge. 30 SQUARE METRE
26 26 Material and labour non skid ceramic colour tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.18 sqm and n.exc 0.38 sqm, in floorss etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 all as specified and as directed by Engineer in charge. 12 SQUARE METRE
27 27 Ditto as per Item No 26 above but on vertical surfaces such as skirting, dados and risers to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing plaster in CM 1:4 all as specified and as directed by Engineer in charge. 3 SQUARE METRE
28 28 Supply only integral waterproofing compound. 25 KILOGRAM
29 29 S&F Aluminium colour coated door frame and shutter single or double leaf glazed/prelaminated board partly glazed. Panels fabricated including aluminium anodised frame tinted glass 5.5mm thick. The door frame should be fixed with aluminium anodised beading rubber and packing material and shall be drilled in existing wall and thurst bolt suitable saizeas all as spd. The door frame and shutter shallbe made as under:- 4 SQUARE METRE
30 29.01 (a) Aluminium colour coated door frame of section 101 x 44 x 3mm
31 29.02 (b) Aluminium colour coated bottom rails of shutter section 200 x 44 x 3mm
32 29.03 (c Aluminium colour coated top , middle/lock rail of shutter section 150x44x3mm.
33 29.04 (d) Six lever mortice lock brass Make: GODREJ/ARGENT 01 each door
34 29.05 (e) Aluminium colour coated tower bolt 200mm long 02 Nos each door
35 29.06 (f) Aluminium colour coated handle 150mm long 2 nos
36 29.07 (g) Heavy duty door machine ISI marked or equivalent as approved
37 29.08 (h) Tinted glass 5.5 mm thick . Make : MODI/SWASTIC
38 29.09 (J) 5mm thick UPVC sheet . Make: Rajshree/sintex
39 30 S&F aluminium colour coated glazed (5.5 mm thick glass) three track sliding window including suitable size frame of powder coated aluminium and rubber gasket/lining comprising of the locking arrangement base rollers etc complete. Thickness of aluminium section should not less than 2mm thick all as specified and as directed by Engineer in charge. 4.8 SQUARE METRE
40 31 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and as directed by Engineer in charge. 16 CUBIC METRE
41 32 Removing excavated material exc. 250m but n exc. 500 m and depositing where directed 35.61 CUBIC METRE
42 33 Dismantling structural steel work including doors, gates but excluding framed truss etc. 1.5 QUINTAL
43 34 Demolition of Concrete of any description and in any position not otherwise specifically provided for RCC Pillars. 2 CUBIC METRE
44 35 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil. 8.5 CUBIC METRE
45 36 Excavating in trenches, n exc 1.5 m wide and each additional 1.50 m or part thereof in depth beyond the first 1.5 m etc. or for shafts, wells, cesspits, manholes, pier holes, etc.getting out in hard/dense soil. 1.75 CUBIC METRE
46 37 Demolition of brickwork built in cement mortar including all quoins, arches, pillars, etc. 8 CUBIC METRE
47 38 M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and as directed by Engineer in charge. 1.78 CUBIC METRE
48 39 Rendering 10mm thick in cement plaster 1:3 over the concrete surfaces as in vertical surfaces even and smooth without using the extra cement all as specified and as directed by Engineer in charge. 25 SQUARE METRE
49 40 S/F Framed work (Fe 410-w (Gde E-250) quality A) as in door or gates of angles or other section with gusset plates, rails, braces, etc,complete drill for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and incl either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting) and hanging; incl lock arrangement also fastening and auranamental items for gate and fixing complete all as specified and as directed by the Engineer-in-Charge. 880 KILOGRAM
50 41 S/F Steel work in tubular trusses including special shape washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 complete all as specified and as directed by Engineer-in-Charge. 191 KILOGRAM
51 42 M&L for preparing new steel surfaces and painting 2 coats of synthetic enamel paints over a coat of red oxide primer all as specified and as directed by Engineer in charge. 55 SQUARE METRE
52 43 M&L for PCC 1:2:4 Type Bo, using 12.5mm aggregate as in coping concrete all as specified and as directed by Engineer in charge. 0.1 CUBIC METRE
53 44 M&L preparation of new plastered surfaces and applying two coats of cement paint over one coat of chalk whiting primer all as specified and as directed by Engineer in charge. 23 SQUARE METRE
54 45 Rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement all as specified and as directed by the Engineer-in-Charge. 50 SQUARE METRE
55 46 Rendering 10 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces all as specified and as directed by the Engineer-in-Charge. 32 SQUARE METRE
56 47 S&F 4mm dia galvanised steel wire, 150x100 mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling all as specified and as directed by the Engineer-in-Charge. 2 SQUARE METRE
57 48 S/F 1.00 mm mild steel plain black sheet covering to door shutter or similar work , cut to size ,holes punched incl round headed screws,clout nails or rivets and fixed to wood or steel frames with plain 40 mm lap joints with riveted or welded seams ,including bending or turning up, mitred angles ,etc as required complete all as specified and as directed by the Engineer-in-Charge. 4 SQUARE METRE
58 49 M&L cement concrete 1:2:4 type B-0 (using 20mm graded aggregate) in bed plates, kerbs slightly rounded or chamfered angles and throating, all as specified and as directed by the Engineer-in-Charge. 0.42 CUBIC METRE
59 50 S&F 0.63mm thick Black corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roof all as specified and as directed by the Engineer-in-Charge. 40 SQUARE METRE
60 51 Returnig, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and as directed by the Engineer-in-Charge. 2 CUBIC METRE
61 52 M&L cement concrete 1:2:4 type B-0 (using 20mm graded aggregate) 40 mm thick and finishing cement concrete surface even and smooth without using extra cement all as specified and as directed by the Engineer-in-Charge. 18 SQUARE METRE
62 53 Surface dressing n.exc 15cm deep in hard dense soil all as specified and as directed by Engineer in charge. 36 SQUARE METRE
63 54 M&L for Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in hard / dense soil all as specified and directed by Engineer in charge. 88 SQUARE METRE
64 55 M&L for PCC 1:4:8 Type D2 using 40 mm graded aggregate, 100mm thick as sub base complete all as specified and directed by Engineer in charge. 190 SQUARE METRE
65 56 M&L 15mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc complete all as specified and as directed by Engineer in charge. 190 SQUARE METRE
66 57 M&L for hydrolic pressed chequered cement concrete tiles 30 cm x 30cm x 25mm thick, se,t jointed in neat cement slurry and pointed in grey cement with pigment to match the colour of tiles all as specified and as directed by Engineer in charge. 190 SQUARE METRE
67 58 Demolition of concrete (unreinforced) in ground floor and pavings n.exc 15cm thickness including rubbies removing. 18.75 CUBIC METRE
68 59 M&L for Point wiring with 1.5 sqmm FRLS grade PVC insulated unsheathed two single core multistranded copper conductor, 1100 V grade drawn through in and including 20 mm dia PVC conduit, ISI marked, concealed on walls and fixed on surface on columns ad slab and with 1.5 Sqmm unsheathed, stranded copper FRLS cable for continuous earth wire terminated with and including pressed modular metal concealed terminal boxes of reqd size, inner frame with outer cover suitable to accommodate modular switches/sockets/regulators all as specified & directed for the following :-
69 59.01 (a) One light/C.Fan controlled by one switch 4 EACH POINT
70 59.02 (b) One point for socket outlet 5 amp same board 2 EACH POINT
71 60 M&L for circuit / submain wiring with 2X2.5 sqmm FRLS grade PVC insulated unsheathed two single core multistranded copper conductor, 1100 V grade drawn through in and including 20 mm dia PVC conduit, ISI marked, concealed on walls and fixed on surface on columns ad slab and with 2.5 Sqmm unsheathed, stranded copper FRLS cable for continuous earth wire terminated with and including pressed modular metal concealed terminal boxes of reqd size, inner frame with outer cover suitable to accommodate modular switches suitable for 15 Amps switch on independent board. 20 RUNNING METRE
72 61 Supply and hang ceiling fab 5 star rated, 1200mm sweep, energy efficient suitable to function on 230 volts, single phase AC supply complete including connecting with and provision of PVC sheathed 3core 1.5 Sqmm flexible copper conductor from ceiling rose to fan connector complete all as specified and directed.\nMAKE: Havells Cat No. ES-50 Premium or techno commercially equivalent model in Philips and Crompton Greaves. 2 EACH JOB
73 62 S&F switch piano flush type 5 amps, 230V AC single pole one way all as specified and as directed by Engineer in charge. 7 EACH
74 63 S&F Socket outlet 2 in 1, 3 Pin, 5A flush type all as specified and as directed by Engineer in charge. 2 EACH
75 64 M&L for ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and as directed by Engineer in charge. 4 EACH
76 65 S&F stepped type electronic fan regulator flush type all as specified and as directed by Engineer in charge. 2 EACH
77 66 S&F LED Post-top light fitting energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs mounted on brick or concreate piller with 76mm dia GI Pipe Make :- Havells RUBYPT25WLED757PSYMTOPC or equivalent 2 EACH
78 67 S&F LED light fitting batten type 4 feet mounted on wall or ceiling incl connection complete all as specified and directed . Make: Havells STOUTMINI1200BS40WLED865SPCWH or equivalent 2 EACH