Special Repair To Roof Treatment At P 56 Pvc Door In Lieu Of Wooden Door Provn Of Toilet For Girls At Bldg No T20 Bw Lines 01 Toilet Cum Bath Room At 883 Asc Bn Scooter Cum Cycle Stand At Bldg No T201 Bw Line And Certain Sanctioned Work Under Ge E Bareil, BAREILLY-Uttar Pradesh

Military Engineer Services-MES has published Special Repair To Roof Treatment At P 56 Pvc Door In Lieu Of Wooden Door Provn Of Toilet For Girls At Bldg No T20 Bw Lines 01 Toilet Cum Bath Room At 883 Asc Bn Scooter Cum Cycle Stand At Bldg No T201 Bw Line And Certain Sanctioned Work Under Ge E Bareil. Submission Date for this Tender is 03-02-2021. Toilet Bathroom Tenders in BAREILLY Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26617545
Special Repair To Roof Treatment At P 56 Pvc Door In Lieu Of Wooden Door Provn Of Toilet For Girls At Bldg No T20 Bw Lines 01 Toilet Cum Bath Room At 883 Asc Bn Scooter Cum Cycle Stand At Bldg No T201 Bw Line And Certain Sanctioned Work Under Ge E Bareil
Open Tender
Indian
Uttar Pradesh
BAREILLY
03-02-2021

Tender Details

Special Repair To Roof Treatment At P 56 Pvc Door In Lieu Of Wooden Door Provn Of Toilet For Girls At Bldg No T20 Bw Lines 01 Toilet Cum Bath Room At 883 Asc Bn Scooter Cum Cycle Stand At Bldg No T201 Bw Line And Certain Sanctioned Work Under Ge E Bareil

Key Value

Document Fees
INR 500 /-
EMD
INR 93500.0 /-
Tender Value
Refer document

BOQ Items

AME OF WORK: SPL REPAIR TO ROOF TREATMENT AT P-56, PVC DOOR IN LIEU OF WOODEN DOOR, PROVN OF TOILET FOR GIRLS AT BLDG. NO T-20 BW LINES, 01 X TOILET CUM BATH ROOM AT 883, SCOOTER CUM CYCLE STAND AT BLDG. NO -6-201 BW LINE AND CERTAIN SANCTIONED WORK UNDER GE(E) BAREILLY
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Demolition of concrete of any description and in any position not otherwise specifically provided for any positionetc complete all as specified and directed . 0.5 Cum
2 2 Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles etc complete all as specified and directed . 1 Cum
3 3 Taking down shutter of any description exc. 1 sqm but n.exc 2 sqm each and removing from site etc complete all as specified and directed . 258 Each
4 4 Taking down chowkats or frames with shutter (without taking of shutter from the frame ) exc 1.50 sqm and n.exc 4 sqm each etc complete all as specified and directed . 30 Each
5 5 Dismantling water tanks 500 & n exc 1000 and removing to store of all retrieved material etc complete all as specified and directed . 4 Each
6 6 Disconnecting existing tanks exc 500 ltr & n exc 1000 ltr, setting aside (or lowering if required) for repairs, cleaning,repairing incl cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc. etc. and hositing if required reconnecting and re-fixing in position. (Cleaning repairing etc. measured separately).etc complete all as specified and directed 4 Each
7 7 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed 59 Sqm
8 8 Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store etc complete all as specified and directed 74 RM
9 9 Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. 50 RM
10 10 Taking down cement plaster of any description in any postion incl hacking out and scrubing down with water etc complete all as specified and directed 200 Sqm
11 11 Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in hard dense soil etc complete all as specified and directed 50 SQM
12 12 Excavating in trenches n. exc. 1.5 m wide, and n.exc. 1.5 m in depth for foundation etc. n.exc. 10 sqm on plan and n. exc. 1.5 mtr in depth and getting out hard/ dense soil.etc complete all as specified and directed 55 Cum
13 13 Excavating in post holes (or similar holes) each n. exc. 0.5 cum, gettting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25 cm, watering and removing surplus soil to a distance n exc. 50 mtr and making good surface. 6 Each
14 14 Excavating over areas, n exc 1.5m deep and getting out soft/ loose soil etc complete all as specified and directed v 9 cum
15 15 M&L for PCC (1:4:8) type D2 using 40mm graded agg as in foundation and mass concrete etc complete all as specified and directed . 16 Cum
16 16 M &L PCC (1 :2:4) type B2 using 40mm agg as in post holes etc complete all as specified and directed 2 cum
17 17 Returning filling in, including, spreading, levelling, watering and well ramming in layers n. exc. 25 cm etc complete all as specified and directed 36.6 Cum
18 18 Removing excavated material n. exc. 50 mtr and depositing where directed at a level n. exc. 1.5 mtr above the starting point etc complete all as specified and directed . 46.5 Cum
19 19 Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces etc complete all as specified and directed . 35 SQM
20 20 Formwork to sides of pillars, posts, struts, piers,columns, and stanchions fair finished surfaces etc complete all as specified and directed 30 SQM
21 21 M&L for from work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work n.exc. 200 mm thick curved ( horizontal or sloping ) with fair finished surfaces for flat roof etc complete all as specified and directed . 71 SQM
22 22 Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams,etc complete all as specified and directed 40 SQM
23 23 Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizintal or sloping and similar work exc 10cm but n exc 20cm wide etc complete all as specified and directed 12 RM
24 24 M&L for re-inforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) inFoundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, underremaed pliles and mass concrete etc complete all as specified and directed 4 Cum
25 25 M&L for re-inforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts etc complete all as specified and directed 6 Cum
26 26 M&L for re-inforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs andd in shelves and the likeetc complete all as specified and directed 13 Cum
27 27 M&L for re-inforced cement concrete (nominal mix) type B1 (1:2:4) using (20mm graded stone aggregate) in Chajjas etc complete all as specified and directed 0.5 Cum
28 28 M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. 1720 Kg
29 29 S&F Mild steel TMT bars 5mm dia and over upto and including 10 mm dia in stirrups,spaces and binders and all as specified and directed. 475 Kg
30 30 S&F plate girder or single stanchions, built up of one beam or channnel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections confirming to grade Fe-410-o etc complete all as specified and directed 50 Kg
31 31 .S&F Mild steel bolts purpose made with hexagonal or square head one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut n .exc 5 cm long dia of neck 11 to 15 mm etc complete all as specified and directed . 10 Kg
32 32 S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161-1979 etc complete all as specified and directed 620 Kg
33 33 S&F Pre-coated galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified. 54 SQM
34 34 M&L for framed work such as grills for windows with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars etc complete conforming to Fe 310-0.etc complete all as specified and directed 25 Kg
35 35 M&L for MS work as in clamps, hold fast, wall ties, hooks, angle cleat and similar small articles conforming to Fe 290 Gde E-165 complete all as specified and directed.\n 10 Kg
36 36 S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doo0rs etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and fastening and fixing FE 290 Gde E-165 complete all as spd as directed 800 Kg
37 37 M&L for Fly Ash Brick work with old size bricks having crushing strength not less than 75kg/sqcm, straight or curved on plan bricks built in cement mortar 1:6 complete all as specified. 57.5 Cum
38 38 M&L for Hard core of gauge broken stone or boulders n.exc.63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface etc complete all as specified and directed . 15 CUM
39 39 M& L 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavings etc complete all as specified and directed 45 SQM
40 40 M&L for 40 mm thick damp proof course in plain cement concrete (1:2:4) type Bo to horizontal or vertical surfaces including necessary form work etc complete all as specified and directed 4.5 SQM
41 41 M& L Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area etc complete all as specified and directed 10 SQM
42 42 M & L Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) etc complete all as specified and directed 9 SQM
43 43 M & L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface etc complete all as specified and directed 15 SQM
44 44 M & L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area etc complete all as specified and directed 20 SQM
45 45 M&L Treating the soil along with external perimeter of building at the rate of 2.25 Ltr of emulsion per metre of the perimeter wall etc complete all as specified and directed 20 RM
46 46 M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed. 48 Sqm
47 47 M&L, 10mm thick rendering on brick masonary in cement mortar 1:4 in vertical surfaces etc complete all as specified and directed 51 Sqm
48 48 M&L for Non Skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cemeent to match in coloured tiles etc complete all as specified and directed . 73 Sqm
49 49 M&L for Glazed ceramic tiles in verticle surface (350x250mmx7mm)/450x350x 7mm thick, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to coloured tiles etc complete all as specified and directed 95 Sqm
50 50 M & L 9 to 10 mm thick glazed coloured ceramic tiles ( square/ rectangular) with border , area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match over and including M&L rendering 10mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed. 9 Sqm
51 51 M&L 40mm thick PCC (1:2:4) type B1 using 20mm graded agg as in floor etc complete all as specified and directed 20 Sqm
52 52 M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in coping/benching inside manhole incl necessary from work finished even and smooth without using extra cement etc complete all as specified and directed 0.1 Cum
53 53 M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in roof kerbs, bed block for hold fast coping benching etc including weathering slightly rounded or chamfered angle and throating etc complete all as specified and directed.\n 3 Cum
54 54 M&L Concrete bed to drain pipe in Cement concrete 1:3:6 type C-2 including packing under, and haunching against the sides ofpipes after they are laid and tested; etc complete all as specified and directed 95 RM
55 55 M & L 150 mm dia Reinforced concrte pipes, class NP2, laid and jointed complete with collars laid in trenches and jointes etc complete all as specified and directed 95 RM
56 56 Construction for 100 Users Septic tanks, exc, in ordinary soil, foundation, In PCC 1:2:4, brick work in CM 1:4, RCC. Slab covers including RCC precast manhole cover. having 6mm plate embedded all around/fibre. reinforced cover with angle iron frame Vent shaft.and sludge chambers etc., all as specified and shown in drawings 1 Each Job
57 57 Construction for 200 Users Septic tanks, exc, in ordinary soil, foundation, In PCC 1:2:4, brick work in CM 1:4, RCC. Slab covers including RCC precast manhole cover. having 6mm plate embedded all around/fibre. reinforced cover with angle iron frame Vent shaft.and sludge chambers etc., all as specified and shown in drawings 1 Each
58 58 Construction of Soakage well size 3.0 M dia X 6.0 M deep. \n exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab\n in M-25/ RR masonry / Filling with brick bats, etc., all as specified and shown in drawings 1 Each Job
59 59 Construction of Soakage well size 3.60 M dia X 6.0 M deep. \n exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab\n in M-25/ RR masonry / Filling with brick bats, etc., all as specified and shown in drawings 2 Each
60 60 M &L 75 mm thick PCC (1 :2:4) type B 2 using 40mm graded agg including spike rolling to surfaces or making impressions of expanded metal , whilst the concrete is green. as in path etc complete all as specified and directed 60 SQM
61 61 M & L forming construction joint 30 mm deep x 10 mm wide filled with sealing compound grade 'B'etc complete all as specified and directed 2 X RM
62 62 M&L 10mm thick rendering on concrete surfaces to be finished even and smooth ( w/o using extra cement) in cement mortar 1:3 in roof slab etc complete all as specified and directed 64 Sqm
63 63 M&L for rendering 15 mm thick on fair faces of brick work on concrete surfacs in CM (1:4) on external brick / concrete surface finished even and smooth ( w/o using extra cement) etc complete all as specified and directed 142 Sqm
64 64 M&L for rendering 15 mm thick on fair faces of brick work on concrete internal surfacs in CM (1:6) and finished even and smooth ( w/o using extra cement) etc complete all as specified and directed . 129 Sqm
65 65 M&L for rendering 5 mm thick on fair faces of brick work on concrete surfacs in CM (1:3) on ceiling surface finished even and smooth ( w/o using extra cement) etc complete all as specified and directed 58 SQM
66 66 Supply and fix APP polymeric water proofing membrane, minimum 3 mm thick and weight 4 kg per Sqm with mineral, make Dr fixit tochshield membrane/equivalent with rich bitumen and select polymers blended together to obtain excellent heat resistance & cold resistant by Dr fixit/ equivalent or super thermolay manufactured by M/S IWL Ltd by M/S Capital Steels and chemicals Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd} at the rate of 0.50 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 100 mm and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions complete incl removal of existing treatment all as specified and as directed.Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate with using Dr fixit pidilite LW(+) , of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 85/25 confirming to IS-73, applied@1.20 Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.30 Kg/Sqm (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with two coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate. 50 Sqm
67 67 M&L for treatment of pipe entry points: Preparing the inside surface of core and PVC /MS Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Sealing the lower side with Fast Setting Mortar or appropriate material & packing the gap by pouring free flowable  non shrink cement polymer based grout up to the surface . The bore while the bonding agent is in tacky state. The periphery of PVC pipe & floor surface will be sealed with Hybrid PU Sealant by making a proper cant or dual shrinkage compensated Micro concreteetc complete all as specified and directed .\n 11 Each
68 68 M&L for Bonding Coat: Cleaning the surface with wire brush, water jet etc to remove dust, dirt etc. On clean surface applying a bonding coat of paints Smartcare Multi Purpose Polymer mixed with cement (1:1.5) to reduce the existing surface porosity and as a bond coat for the new surface sceed on the top of the sameetc complete all as specified and directed .. 500 Sqm
69 69 M&L for Resurfacing : Applying and Laying a avg 15 mm thick layer of cementitious polymer modified mortar on the top of the bond coat as per manufacturer's instructions in existing gradient/ slope. Polymer will be added @ 5% to the weight of cement. Solid content of the polymer not less than 54%. The newly constructed surface to be cured with clean water at least for 10 days before applying WP membrane etc complete all as specified and directed .. 500 sqm
70 70 M&L for Surface Preparation: The surface to receive the treatment shall be thoroughly free of laitance, scales, oil or any other loose material. It should be made free of any sharp objects. Cleaning of screed shall be done with wire brushing to attain smooth levelled surface. Cracks shall be rectified, filled using dual shrinkage compensated Repair Mortar , Making of Coves/ vata at the junction / corners in using MPP polymer mixed with cement : sand as per manufacturer's instruction for mortar & water curing the same . After curing period of 72 hours proceed with application of Polyurethane coating.etc complete all as specified and directed . 500 sqm
71 71 M&L for Liquid Applied WP Membrane: Application of Paints two component Epoxy Primer (Resin & Hardener) on the cleaned surface for bonding of Polyurethene with the existing concrete surface. 33 % water dilution is recommended with the pure mixed primer. The primer mixing ratio will be 1:3(Resin:Hardner)\nSupplying, providing and applying waterproofing treatment to terrace area with single component highly elastomeric seamless cold applied modified PU coating complete as per manufacturer’s specifications and application methodology. The same coating shall be applied in two coats achieving an avg. thickness of 1mm. The coating shall have a dual combination of 280% elongation. The Material will be applied @ coverage 1.2kg /sq.mt. A 10 Years Company Bank warranty to be provided after completion of the work. The work shall be got carried out/ executed under Smart Assure system.etc complete all as specified and directed . 500 sqm
72 72 M & L for cool roof antiskid tiles 300x300x10 mm with high SRI value not less than 90 laid over existing treatment on accessible roof and including 3 MM thick paint Tile Adhesive for normal application a single component cement based polymer modified adhesive for fixing tiles on floors and walls in interiors as well as exteriors.coverage area is 4.4 kg/sqm.etc complete all as specified and directed .NOTE for Item no 68 to 72 above :- The work shall be got carried out by the manufacturer or their authorized applicators\n 500 sqm
73 73 M & L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed . 55 SQM
74 74 S&F 30 mm thick factory made both side Prelam PVC sheet used instead of Plain colour PVC sheet. Stile and rails feathered at edges consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. 364 Sqm
75 75 S & F 200 mm long Stainless Steel Plain , barrel tower bolts of extruded section and fixed with welding complete all as specified and directed 288 Each
76 76 S&F Stainless Steel handle with high grade two tone Finish 192 mm long , Perfect Mixture Of Graded Stainless Steel and Zinc Alloy. 100% Rust Proof Material Guaranty with Suitable Screws and Allen Key completed all as specified and directed. 456 Each
77 77 S&F 300 mm long Stainless steel sliding door bolts( without locking arrangements) not less than 16 mm dia with and including a minimum of 6 bolts and nuts, 04 Nos on bolt plate and 02 Nos on staple plate and fix with as welding complete all as specified and directed 288 Each
78 78 S&F 100 mm size butt hinges medium weight stailess steel colled rolled complete all as specified and fix with welding etc complete all as specified and directed 400 Each
79 79 S&F Powder coated aluminium ventilators box type with louvers & wire mess neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below- (i) Window frame :63x35mm X 1.48 mm thick for two tracks.\n(ii) Top/bottom rail and style / rail of shutter: 19x38x1.48mm thick and over. (iii) Aluminium beading - 0.7mm thick \n(iv) Aluminium neccessary fittings complete as required basis. \n(v) Making good of wall surfaces to match with existing surfaces complete all as specified and directed. 5 Sqm
80 80 S&F aluminium alloy powder coated aluminium door frame fixed with side hung shutters and glazing fixed with and including 5 mm thick aluminium composite panel LDPE core PET coating ( both side decorative type ) fixed with rubber gasket with aluminium heading, clips frame made with aluminium box sec as appended below complete all as specified and directed \n(a) Frame 100x44x1.48mm thick with rawl plug\n(b) Middle and lock rail : 150x44x1.48mm thick\n(c) Bottom rail : 150x44x1.48mm thick\n(d) Top rail/style : 85x44x1.48mm thick\n(e) Aluminium beading : 0.7mm thick\n(f) Aluminium handle D type 150mm long, aluminium tower bolt 9.9mm dia shoot 200mm long brass mortise lock 100mm 4 leaver , with S S hinges complete \n(g) Making good of wall surface to match with existing surface complete. 20 Sqm
81 81 S&F looking mirror of size 600x 450mm bevelled edge mirror of selected quality glass , mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers etc complete all as specified and directed 5 Nos
82 82 S & F viteous china squating pan " ORISSA PATTERN" of size 580mm x 440mm white with integral foot rest or back inlet incl PCC 1:2:4 type B-1 for making good the floor complete all as specified as fixed in repairs etc complete all as specified and directed 7 Each
83 83 S&F PVC valveless, symphonic action type 10 ltr capacity flushing cistern, low level, white with inlet, ball valve, float and handle including brakcet (any colour or design approved by GE) etc complete all as specified and directed . 7 Each
84 84 S&F PVC connections 15 mm size with PTMT nuts of length 450 mm.etc complete all as specified and directed 15 Each
85 85 S&F vitreous China bowl urinal flat back size 430x370x340 with grating and union for discharge pipe excluding flushing cistern flush pipe and waste pipe etc complete all as specified and directed 5 Each
86 86 S&F vitreous chinaware coloured wash hand basin with pedestal of size 55X45X82cm complete including fancy CP pillar tap, CP Waste coupling ,waste pipe ,complete fixing arrangement and cutting for and pinning in walls & making good etc complete all as specified and directed 4 Each
87 87 S&F ball valves,high pressure of PTMT of 15 mm dia with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed.(Min weight 15 mm dia 142 gms)etc complete all as specified and directed 4 Each
88 88 S & F 20 mm dia Gun-metal, golbe or gate valves, with iron wheel head, screwd both end for iron pipe and fixed etc complete all as specified and directed 11 Each
89 89 S&F in repairs of 15mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed etc complete all as specified and directed 7 Each
90 90 S&F 15 mm dia bib tap (Fancy type cromium plated) cast copper alloy with crtuch or butter fly handle screwed down for iron pipes or for brass ferrule and fixed etc complete all as specified and directed . 8 Each
91 91 S&F 15 mm stop valves,but fancy type, chromium plated with long shank and cup (conncelaed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed etc complete all as specified and directed . 7 Each
92 92 S&F for 15mm bore `Medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. 134 RM
93 93 S&F for 20mm bore `Medium grade` GI tubing with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed . 110 RM
94 94 S&F (SWR) floor trap of 75 mm dia, plain with grating including jointing with solvent cement.etc complete all as specified and directed 6 Each
95 95 S&F PVC (SWR) bends of 110 mm dia.etc complete all as specified and directed 12 Each
96 96 S&F 110 mm dia PVC (SWR) pipes single socket, in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed 30 RM
97 97 S&F 110 mm dia PVC (SWR) pipes single socket, in any length with rubber ring joints fixed to walls etc complete all as specified and directed 24 RM
98 98 S&F 110 mm dia PVC (SWR) vent cowl etc complete all as specified and directed 3 Each
99 99 S&F chromium plated brass tubular towel rail 20 mm dia and 600mm long, D type for wash hand basin centre holed fixed to iron pipe complete all as specified and directed. 7 Each
100 100 S&F 500 litres, rotational moulded polyethylene white colour in tripple layer water storage tank (cylindrical vertical with closed top with suitable size of 1 mm thick M S Tasla with suitable locking system ), hoisted and fixed in position complete all as specified and directed . 7 Each
101 101 S&F 1000 litres, rotational moulded polyethylene of white colour in tripple layer water storage tank (cylindrical vertical with closed top with suitable size of 1mm thick M S Tasla with suitable locking system ), hoisted and fixed in position complete all as specified and directed 1 Each
102 102 S&F Ball brass valves 20mm, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed 3 Each
103 103 M&L for Surface Preparation of wall The surface to receive the treatment shall be thoroughly free of laitance, scales, oil or any other loose material. It should be made free of any sharp objects. Scrapping and sanding of paint is to be done, if exist. Cracks shall be rectified, filled using dual shrinkage compensated Repair Mortar and dried for 72 hours before laying the membrane. Apply smart care roof tape at all the joints in the wall etc complete all as specified and directed 200 sqm
104 104 Providing Labour and material for smart care Roof tape which needs to applied on all the corners and sandwitched between 2nd and 3rd coat of Damp Proof etc complete all as specified and directed 200 sqm
105 105 Providing Labour and Material to apply Paints Damp proof which is a fiber reinforced elastomeric liquid applied membrane with SRI value of 105, upon curing, it should forms a seamless, durable membrane offering ultimate waterproofing; First Coat to be applied as a self priming coat with dilution of 33% with water and 2nd and 3rd coat to be applied without any dilution in the gap of 4-6 hrs. etc complete all as specified and directed 200 sqm
106 106 M&L for preparation of new plaster surface applying two coat of cement base paint over a coat of primer on wall surfacesetc complete all as specified and directed 105 Sqm
107 107 M&L for preparation of new plaster surface of wall applying two coat of oil bound distemper over and including 1mm thick wall care putty complete all as specified and directed. 20 Sqm
108 108 M&L for preparation of newly plastered surfaces and applying three coat of white wash on wall.etc complete all as specified and directed 55 sqm
109 109 M&L for preparation of new plaster surface applying three coat white wash on surface a on ceiling complete all as specified and directed. 58 Sqm
110 110 M&L for Preparation of new steel surfaces of any description, over 10cm in width or girth not otherwise described two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. 50 Sqm
111 111 M&L for Preparation of new wooden surface applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 10 Sqm
112 112 supply for integral water proofing compound complete all as specified and directed. 8 Kg
113 113 Taking down copper/aluminum point wiring (Light fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting holders etc, removing materials for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces of wall, floors etc complete all as specified and directed. 50 Per point
114 114 Taking down light fittings any and making good disturbed surfaces to match with the existing surfaces of walls including removing of site etc complete all as specified and directed. 20 Each
115 115 Taking down sub main wiring including earth wire and making good disturbed surfaces to match with the existing surfaces of walls including removing of site etc complete all as specified and directed. 90 RM
116 116 Taking down ceiling/exhaust fan and disconnecting, removing to store for keeping in safe custody in MES etc complete all as specified and directed.. 4 Each
117 117 Taking down & disconnecting Electric Water storage heater (Geyser) of any capacity and removing to store for keeping in safe custody in MES for reinstallation etc complete all as specified and directed.. 2 Each
118 118 Taking down main switch / MCB/ DBS including MC BS etc of any size removing for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces of wall, floors etc complete all as specified and directed. 2 Each
119 119 M&L Point wiring with standard copper conductor FLRS unsheathed 1100 V cables PVC 1.5sqmm single core in and including PVC Conduit conceald not less than 20 mm dia complete cutting and chasing using for terminal box of adequate size with 3mm thick laminated sheet cover etc for one light /fan /Exhaust fan /bell point controlled by one, one way switch including 1.5sqmm cable as earth wire connected to earth dolly complete all as sepecified and directed. 70 Per point
120 120 All as per item No.120 here in before but for One 3 ;pin socket oultel 5 Amp on the same board with other switch. 4 Per point
121 121 All as per item No120 here in before but for One 3 pin socket outlet 5 Amp independent 4 Per point
122 122 All as per item No.120 here in before but for one 5 pin socket outlet 15 Amps independent using 4.0 Sqmm PVC insulated & unsheathed copper conductor cable(multistranded) and 2.5Sqmm cable for earth wire etc complete all as specified and directed. . 7 Per point
123 123 S&F switch piano type, flush type single pole one way 5 Amp, 230Volt complete all as specified and directed. 78 Each
124 124 S&F switch piano, flush type single pole one way 15 Amp, 230Volt complete all as specified and directed. 7 Each
125 125 S&F Socket outlet 2 in 1, 3 pin 5 Amp flush type (Multi purposes ) , 230Volt complete all as specified and directed. 8 Each
126 126 S&F socket outlet 2 in 1, 3 pin 5Amp and 15 Amp, flush type (Multipurposes), 230Volt complete all as specified and directed. 7 Each
127 127 S&F Ceiling rose 3 terminals, PVC / polycarbonate, isolated body complete all as specified and directed. 31 Each
128 128 Installation only Water heater storage type, electric of any capacity with complete accessories 230V received from Item Sl No 5 including Hot & cold water supply connection and fixing with nuts, bolts & washers and electric connection also.. 2 Each
129 129 S&F Lamp holder, PVC/Polycarbonate type with back plate for batten fittings complete all as specified and directed. 31 Each
130 130 S&F Lamp LED Retrofit lamp B-22 holder base with poly carbonate diffuser 9 Watt, 230 Volt complete all as specified and directed. 31 Each
131 131 S&F LED Bulk head light fitting 10 Watt with Engineering plastic housing & clear prismatic diffuser, heat sink integrated including smd LED 10Watt complete all as specified and directed. 8 Each
132 132 S&F Ultra slim LED MS Batten light fitting 1X20Watt , powder coated decorative end cap complete with retrofit poly carbonate glass tube LED 20W, 4' long including suitable electric connection with three core flexible PVC insulated copper conductor(multistranded) cable of 1.0sqmm from ceiling roze to batten complete all as specified and directed. 18 Each
133 133 S&F Ultra slim LED MS Batten light fitting 1X10Watt , powder coated decorative end cap complete with retrofit poly carbonate glass tube LED 20W, 2' long including suitable electric connection with three core flexible PVC insulated copper conductor(multistranded) cable of 1.0sqmm from ceiling roze to batten complete all as specified and directed. 2 Each
134 134 Supply & Fix in replacement of exhust fan 375mm sweep , Iron body, 3-4 blades, AC, 230 Volts complete with louvers etc including suitable electric connection with three core flexible PVC insulated copper conductor(multistranded) cable of 1.0sqmm from ceiling roze to batten complete all as specified. 4 Each
135 135 S & F Exhaust fan AC single phase, heavy duty, 230/240 Volts, of size 300 sweep with louvers etc complete all as specified and directed. 1 Each
136 136 Supply & Fix in replacement of exhust fan 250mm sweep , PVC body, 3-4 blades, AC, 230 Volts complete with louvers etc including suitable electric connection with three core flexible PVC insulated copper conductor(multistranded) cable of 1.0sqmm from ceiling roze to batten complete all as specified. 6 Each
137 137 M & L for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through in PVC conduit all as directed.Note : 2 run of wire + 1 run of earth wire + 1 run of PVC conduit will be measured as one unit 90 RM
138 138 S&F sheet metal enclousers (DBS) when MCBs to be used 4 way, 240 Volts, double door Single pole & neutral with 200 Amps rated bus bar.(MCBs are to be measured and paid for seperately) 2 Each
139 139 S&F sheet metal enclousers (DBS) when MCBs to be used 8way double door single pole & neutral with 200 Amps rated bus baretc complete all as specified and directed.. 3 Each
140 140 S&F MCB single pole & neutrall of size 16A to 63 Amp, 230V, 10KA, B curve type etc complete all as specified and directed.. 5 Each
141 141 S&F MCB single pole of size 6A to 32 Amp 230 Volt, B curve type etc complete all as specified and directed. . 22 Each
142 142 Supply & laying sub class B bricks, well burnt , laid wirdth wise along the length of cable laid in trench over sand cushion laid for cable protection, complete as specified and directed. 810 Each
143 143 Material and labour for river washed and sreened, dry sand for filling in trench below and around the under ground cable for cushioning of cable etc, complete all as specified. 4.4 Cum
144 144 M&L for Boring of holes under road or cutting theroad/path/pavement/hard standing or any other situation by mannual means for 40mm/25mm bore GI pipe for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measured and paid separately under respective item. 8 RM
145 145 Supply & fix tube 25mm bore light grade GI with all fittings for cable protection for road crossing/ culvert/ path/ on wall/ floor/ pole/ across the road/path/culverts or laid in floor etc complete all as specified and directed.. 11 RM
146 146 Supply, Laying and testing cable XLPE insulated, screened, PVC bedded,GI steel strip or wire armoured, electric power cable ( heavy duty ), 1100Volts with stranded aluminium conductor of size 6 sq mm 2 core.etc complete all as specified and directed. 60 RM
147 147 Supply, Laying and testing cable XLPE insulated, screened, PVC bedded,GI steel strip or wire armoured, electric power cable ( heavy duty ), 1100Volts with stranded aluminium conductor of size 10sq mm 2 core etc complete all as specified and directed.. 40 RM
148 148 M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts,check nuts, nuts and washers of GI or steel all as shown in electrical plate No 5 of SSR-I connected to earth test point by means of nut, bolts and washers made out of galvanised iron or steel all including earthing pit in PCC (1:3:6) type C1,RCC (1:2:4) type B1 precast cover slab with one handle made out of 8 mm dia round bar,20 mm dia (medium grade) protecation pipe and providing layer of charcoal or coke and salt in alternative layers,necessary earth work complete as specified or indicated including testng on completion..Note :- Tenderer may note that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract 4 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy