Provision Of Certain Special Repair , Revenue And Minor Works Under Age E/M At Bb Cantt Srinagar, BB CANTT SRINAGAR-Jammu And Kashmir

Military Engineer Services-MES has published Provision Of Certain Special Repair , Revenue And Minor Works Under Age E/M At Bb Cantt Srinagar. Submission Date for this Tender is 04-02-2021. Civil Work Tenders in BB CANTT SRINAGAR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

26617528
Provision Of Certain Special Repair , Revenue And Minor Works Under Age E/M At Bb Cantt Srinagar
Open Tender
Indian
Jammu And Kashmir
BB CANTT SRINAGAR
04-02-2021

Tender Details

Provision Of Certain Special Repair , Revenue And Minor Works Under Age E / M At Bb Cantt Srinagar

Key Value

Document Fees
INR 500 /-
EMD
INR 48000.0 /-
Tender Value
INR 24 Lakhs /-

BOQ Items

Name of Work : PROVN OF CERTAIN SPECIAL REPAIR, REVENUE AND MINOR WORKS UNDER AGE E/M AT BB CANTT SRINAGAR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, installation, testing and commissioning of Walk - in cold room of two chambers for Medical Storage of nominal size 12' x 10' x8' consisting of wall and ceiling panel made out of PGI sheet filled with 60 mm PUF insulation, anti skid GI flooring on 60 mm PUF, door of suitable dimension, hydraulic door closer, digital temperature indicator, Air cooled medium temperature split unit of 3 HP rating with Reciprocating/Scroll Compressors working on R 22/R - 410a refrigerants to maintain temperature of 4+/- 2 degree Centigrade at an ambient temperature of 30 degree centigrade. Make: Blue star/ Voltas 1 Each
2 2 Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 10 KVA complete all as specified and directed . 1 Each
3 3 Material and labour for earthing, complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connecting to the galvanised iron earth lead wire of 4mm dia by means of bolts, nuts, check nuts and washers of galavanised iron and earth strip protected by provision of GI light grade pipe 20mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded of stone aggregate with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm/6mm flat iron with fixing arrangement funnel wire mesh and earth work in hard dense soil returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electrical plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. 2 Each
4 4 S&F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 complete all as specified and directed. Amp Make: L&T/ Havells/ ABB 2 Each
5 5 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed. Make: Anchor/ Polycab/Finolex 133 RM
6 6 Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any kind of soil complete all as specified and directed. (cable shall be laid 60 cm below ground level. 21 Cum
7 7 Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed. 16.6 Cum
8 8 Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point. complete all as specified and directed. 4.6 Cum
9 9 Sand cushioning for cables 8 cm below the cable and 15 cm above the cable all as specified and directed . 6.48 Cum
10 10 Material and labour for old size brick well burnt, laid flat ,for cable protection complete all as specified and directed. 720 Each
11 11 Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed . Make – Ravindra,Oswal,Kinjal. 20 RM
12 12 Supply fixing and commissioning of split type air conditioner unit with hot and cold mode of 2.0 TR capacity along with single evaporator unit wall mounted , condenser unit and with compressor, non ductable corded type suitable for operation on 230Volt 50Hz single phase electric supply including provision of necessary weather proof cover with fixing arrangement on suitable brick masonry platform for protection of condenser /compressor unit from sun , rain and fixing the evaporator inside the bldg with suitable insulation including provn of copper refrigerant piping of suitable length from condensing to cooling coil and vise versa duly overlapped by nitrile insulation, and suitable drain pipe for dropping out the water outside from evaporator duly electric connection with 3core copper cable of suitable size up to the existing mains as required at site and making good of disturbed surface complete all as specified and directed.\nNote: Cost of MS bracket and guard to install condensing unit including painting /grouting for protection from weather, copper pipes PCC raised platform, electric cable for making connection etc as required shall be deemed to be included in unit rate above.Make LG/Hitachi/blue Star/IFB / Voltas \n 1 Each\nSet
13 13 Supply fixing and commissioning of split type air conditioner unit with of 2.0 TR capacity with single evaporator unit wall mounted , condenser unit and with compressor, non ductable corded type suitable for operation on 230Volt 50Hz single phase electric supply including provision of necessary weather proof cover with fixing arrangement on suitable brick masonry platform for protection of condenser /compressor unit from sun , rain and fixing the evaporator inside the bldg with suitable insulation including provn of copper refrigerant piping of suitable length from condensing to cooling coil and vise versa duly overlapped by nitrile insulation, and suitable drain pipe for dropping out the water outside from evaporator duly electric connection with 3 core copper cable of suitable size up to the existing mains as required at site and making good of disturbed surface complete all as specified and directed.\nNote: Cost of MS bracket and guard to install condensing unit including painting /grouting for protection from weather, copper pipes PCC raised platform, electric cable for making connection etc as required shall be deemed to be included in unit rate above.Make LG/Hitachi/blue Star/IFB / Voltas / Godrej\n 3 Each set
14 14 Materal and labour for sub main wiring with two single core 6 Sqmm copper conductor drawn in and including PVC capping and casing surface wiring along with 6 Sqmm copper conductor for earth dolly from building main to AC installation spot complete all as directed.Make: Havells/ Anchor/ Finolex 70 RM
15 15 Supply and fixing sheet metal enclosures with plug top single pole and neutral with two pin and earth plug and socket complete with one MCB SPN 40 Amp complete all as specified and directed. Make : Havells/Indo Asian/Standard 9 Each
16 16 Automatic digital stabilizer wall mounting with low and high voltage cut off and time delay suitable for operation on 230 V AC supply with following :-(a) Input voltage 90 V - 260V (b) Out put voltage 225 + 11 %(c) Low voltage cut off 90 (-) 5 Volts (d) High voltage cut off 260 V + 5 Volts (e) Time delay adjustable from 30 second to 03 minutes capacity 5 KVA complete all as specified and as directed.\nMake- Make- V guard /Livegaurd / Venus \n\n 9 Each
17 17 Supply & fix deep freezer Metal Hard top (300-320) litre capacity, single phase,4/5 star rated Refrigerant R134A, direct cooling type having minimum temperature range up to (-) 18 degree celsius with double door , corrosion resistance body,PUF insulation of minimum 60 mm, including one basket and heavy duty castors wheel complete all as specified and directed. Make: Blue Star /Voltas/ Haier 2 Each
18 18 Automatic digital stabilizer wall mounting with low and high voltage cut off and time delay suitable for operation on 230 V AC supply with following :- (a) Input voltage 90 V - 260V (b) Out put voltage 225 + 11 %(c) Low voltage cut off 90 (-) 5 Volts (d) High voltage cut off 260 V + 5 Volts (e) Time delay adjustable from 30 second to 03 minutes capacity 2 KVA complete all as specified and as directed. Make- V guard /Livegaurd / Venus \n 2 Each
19 19 M&L for point wiring complete with PVC insulated and unsheathed, flame retardant ( FRLS ) Flame retardant low smoke 1100 volt grade electric cable of 4 sqmm (nominal area) with multi stranded copper conductor 2 single core for 15 amps independent power point in and including PVC casing & caping with suitable MS terminal boxes ( not less than 1.0 mm thick )and painted with one coat of red oxide primer all around and two coats of black bituminous paint including earth dolly with 3 mm thick plastic laminated sheet top cover of approved colours including 2.5 sqmm green stranded copper conductor as continuous earth wire with all accessories, complete all as specified and as directed. \n 2 Per Point
20 20 S & F Switch and socket combination 6 pin 15 Amp AC 230 Volts piano flush button type (multipurpose) complete all as specified and directed. 2 Each
21 21 Supply fixing and commissioning of split type air conditioner unit with hot and cold mode of 1.5TR capacity along with single evaporator unit wall mounted , condenser unit and with compressor, non ductable corded type suitable for operation on 230Volt 50Hz single phase electric supply including provision of necessary weather proof cover with fixing arrangement on suitable brick masonry platform for protection of condenser /compressor unit from sun , rain and fixing the evaporator inside the bldg with suitable insulation including provn of copper refrigerant piping of suitable length from condensing to cooling coil and vise versa duly overlapped by nitrile insulation, and suitable drain pipe for dropping out the water outside from evaporator duly electric connection with 3core copper cable of suitable size up to the existing mains as required at site and making good of disturbed surface complete all as specified and directed.\nNote: Cost of MS bracket and guard to install condensing unit including painting /grouting for protection from weather, copper pipes PCC raised platform, electric cable for making connection etc as required shall be deemed to be included in unit rate above.Make LG/Hitachi/blue Star/IFB / Voltas \n 6 Each Set
22 22 Materal and labour for sub main wiring with two single core 4 Sqmm copper conductor drawn in and including PVC capping and casing surface wiring along with 4 Sqmm copper conductor for earth dolly from building main to AC installation spot complete all as directed. 70 RM
23 23 M&L shifting of existing BER Air conditioner of capacity 1.5 ton from 31 Sub Area offr mess to MES store yard at BB cantt including disconnecting and shifiting all electrical & mechanical connection etc. complete all as directed. Note : Air conditiner shall be shifted with proper safety using T&P/man power as required and same is deemed to be incl in quoted rates. 4 Each Job
Disclaimer :