Special Repair Incl Flooring , Rewiring , False Ceiling , Roof Treatment , Re-Plastring , Replacement Of Doors And Windows Of Bldg No T-452 To T-455 ( 02 X Or Living And 02 X Dining Hall ) At Hisar Mil Stn Under Ge Hisar, Hisar-Haryana

Military Engineer Services-MES has published Special Repair Incl Flooring , Rewiring , False Ceiling , Roof Treatment , Re-Plastring , Replacement Of Doors And Windows Of Bldg No T-452 To T-455 ( 02 X Or Living And 02 X Dining Hall ) At Hisar Mil Stn Under Ge Hisar. Submission Date for this Tender is 06-02-2021. Electrification Work Tenders in Hisar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

26617171
Special Repair Incl Flooring , Rewiring , False Ceiling , Roof Treatment , Re-Plastring , Replacement Of Doors And Windows Of Bldg No T-452 To T-455 ( 02 X Or Living And 02 X Dining Hall ) At Hisar Mil Stn Under Ge Hisar
Open Tender
Indian
Haryana
Hisar
06-02-2021

Tender Details

Special Repair Incl Flooring , Rewiring , False Ceiling , Roof Treatment , Re-Plastring , Replacement Of Doors And Windows Of Bldg No T-452 To T-455 ( 02 X Or Living And 02 X Dining Hall ) At Hisar Mil Stn Under Ge Hisar

Key Value

Document Fees
INR 500 /-
EMD
INR 41800.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : SPL REPAIR INCL FLOORING, REWIRING, FALSE CEILING, ROOF TREATMENT, RE-PLASTRING, REPLACEMENT OF DOORS AND WINDOWS OF BLDG NO T-452 TO T-455 (02 X OR LIVING AND 02 X DINING HALL) AT HISAR MIL STN UNDER GE HISAR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. 130 Sqm
2 2 Removing old lime wash (if any), hacking for key, raking out joints of old brick work built in cement mortar, not previously plastered and scrubbing down with water to receive plaster complete all as specified and directed. 290 Sqm
3 3 M&L for 10mm thick rendering in cement mortar (1:6) on fair face of brick walls/ concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed. 240 Sqm
4 4 M&L Rough cast plaster as specified (Rendering coat not less than 10mm thick in C:M 1:3 while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg size 6 to 12mm mixed with coarse sand and cement in the ratio of 1:1:1 mixed with liquid type water proofing compound) @ 200ml per 50kg bag of cement used, shall be applied anbd finished even and fair on external wall upto cill height complete all as specified and directed. 100 Sqm
5 5 M&L for 15mm thick rendering in cement mortar (1:4) on fair face of brick walls/ concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed. 95 Sqm
6 6 Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm thickness below or above ground level complete all as specified and directed. 42 Cum
7 7 M&L for 25mm thick cement concrete 1:2:4, type B-1 using 20mm graded aggregate as in sub floor complete all as specified and directed. 130 Sqm
8 8 M&L for Brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. 10 Cum
9 9 Demolition of brick work built in cement mortar including all quoins, arches pillars etc complete all as specified and directed. 10 Cum
10 10 M&L for 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in Sub base of floor finish complete all as specified and directed. 185 Sqm
11 11 M&L for non-skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick cement screed bed CM (1:6) complete all as specified and directed. 130 Sqm
12 12 Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and removal complete all as specified and as directed. 290 Sqm
13 13 M&L for coloured glazed ceramic tiles of size 450 x 350 x 7mm / 350 x 250 x 7mm thick as in vertical surface like dado or skirting set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar (1:3) complete all as specified and directed. 160 Sqm
14 14 M&L 20-25mm thick Kota stone slabs over and including 20mm thick screed layer in CM (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of stone incl rubbing & mirror polishing complete all as specified and directed.\nNote :- (i) The size of kota stone in flooring shall be 550 x 550mm (minimum).\n(ii) Kota stone on treads of stair case shall be in one piece. 220 Sqm
15 15 M&L 20-25mm thick Kota stone slabs as in vertical surfaces like dado or skirting over 10mm thick rendering in CM (1:3) set & joined in neat cement slurry and pointed in coloured cement to match incl rubbing & mirror polishing complete all as specified and directed.\nNote :- Kota stone on risers of stair case shall be in one piece. 12 Sqm
16 16 M&L Preparation of new plastered or unplastered surfaces of wall and applying two coats of white or tinted cement based paint complete all as specified and directed. 195 Sqm
17 17 M&L Preparation of new plastered or unplastered surfaces of wall and applying two coats of white or tinted oil bound distemper over a coat of alkali resistant primer complete all as specified and directed. 220 Sqm
18 18 M&L for preparation of new steel surface of any description not otherwise described exc 10cm width or girth and applying two coats of synthetic enamels paints over a coat of red oxide primer complete all as specified and directed. 15 Sqm
19 19 M&L for preparation of old steel surface of any description not otherwise described exc 10cm width or girth and applying a coat of synthetic enamel paint complete all as specified and directed. 40 Sqm
20 20 M&L for preparation of new plastered or unplastered surfaces of wall and applying three coats of white wash complete all as specified and directed. 20 Sqm
21 21 M&L for preparation of old plastered or unplastered surfaces of wall and applying one coat of white wash on wall to match existing surface complete all as specified and directed. 20 Sqm
22 22 M&L for preparation of old plastered or unplastered surfaces of wall and applying one coat of oil bound distemper complete all as specified and directed. 30 Sqm
23 23 Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc. 1.50 sqm each complete all as specified and directed. 30 Each
24 24 Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.50 sqm & n.exc 4.00 sqm each complete all as specified and directed. 8 Each
25 25 S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, size of frame 125 x 60mm complete all as specified and directed. 40 RM
26 26 M&L cement concrete (1:3:6) type C-1 (20mm stone aggregate) for filling of pressed steel frame and hold fast block etc including necessary form work complete all as specified and directed. 0.3 Cum
27 27 S&F 35mm thick factory made IInd class hard wood panelled door shutters (any numbers of panel) with panels of 12 mm thick BWR plywood having seven ply with commercial veneers on both face of BWP grade and boded with phenol formaldehyde synthetic resin adhesive ISI mark. The size of rail & stile as per IS :1003 (Part-I) kilnseasoned and chemically pressure treated complete all as specified and directed. 16 Sqm
28 28 S&F 35mm thick factory made glazed and skeleton shutters of 2nd class HW open rebated and prepared to receive glass/gauze etc edges or framing plain chamfered or rounded fitted with cut or mitred beads for securing glass etc as specified in SSR pt-1 section 8, clause 8.24 (a) complete all as specified and directed. 16 Sqm
29 29 S&F in repair (including hacking out of old glass from metal frame) 3mm thick sheet glass ordinary quality and glazing with oil putty or MS clips fixed with steel window frames or wooden beads to wooden frame complate all as specified and directed. 1 Sqm
30 30 S&F 150mm long Aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. 32 Each
31 31 S&F for 150mm long Extruded aluminium alloy handles, cast type, anodised complete all as specified and directed. 48 Each
32 32 M&L for preparation of new wooden surfaces of any description not otherwise described exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed. 46.4 Sqm
33 33 S&F factory made steel window / ventilator, ISI Marked, (Box type) with side hung shutter including projecting type hinges with steel handle and tower bolt and steel peg stay with glazing bar, dovetailed or welded including shop coat of zinc primer and making good disturbed surfaces of walls complete all as specified and directed. \nNote : HQ CEJZ Drawing No TD/2013/01 Sheet 1/3,2/3,3/3. 20 Sqm
34 34 S&F factory made steel window / ventilator, ISI Marked, (Box type) with side hung shutter including projecting type hinges with steel handle and tower bolt and steel peg stay without glazing bar, dovetailed or welded including shop coat of zinc primer and making good disturbed surfaces of walls complete all as specified and directed. \nNote : HQ CEJZ Drawing No TD/2013/01 Sheet 1/3,2/3,3/3. 20 Sqm
35 35 S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. 28 Sqm
36 36 M&L 3mm thick sheet glass, ordinary quality and glazing with oil putty in squares exc. 0.5 Sqm in each pane complete all as specified and directed. 16 Sqm
37 37 Dismantling asbestos cement corrugated or semi corrugated sheets as in roof covering complete all as specified and directed. 560 Sqm
38 38 S&F Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. 530 Sqm
39 39 S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strenght of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed. 30 Sqm
40 40 Dismantling boarding, any description, fixed in any position with nails, cover filletes of any description as in false ceiling including grids and hangers complete all as specified and directed. 370 Sqm
41 41 M&L for GI frame work for seamless ceiling comprising of GI perimeter chanel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27 mm fixed to surrounding wall using nylon sleevs and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre as in frame work to ceiling complete all as specified and directed. 370 Sqm
42 42 S&F 9mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination complete all as specified & directed. 370 Sqm
43 43 Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed. 1.2 Qtl
44 44 M&L for 20mm thick black granite stone slab topping table rubbed and polished (one piece) in cooking platforms / staps, jambs, pillars, window cill laid over 15mm thick cement screed bed or bedding layer in CM (1:4) including pointing in white cement (1:2) using marble dust including rounded / half rounded edge and hole of gas pipe in pre-cast slab as well as stone slab in cooking platform complete all as specified and directed. 2 Sqm
45 45 M&L for rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates, complete including cutting to required length, notching, drilling fitting, reveting and / or welding or connecting with bolts Fe-290 (Gde E-165) complete all as specified and directed. 100 Kg
46 46 S&F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachement complete all as specified and directed. 20 Kg
47 47 S&F mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n.exc 10cm long and diameter of neck 11 to 15mm complete all as specified and directed. 0.5 Kg
48 48 M&L 60mm thick machine pressed precast cement concrete interlocking paver block with grey cement and no pigments of grade M-35 of any shape and size confirming to IS-15658-2006 such as I-Shape, unioctagenal, three X, dumble, zigzag etc laid over and including 25mm thick sand cushion complete all as specified and directed. 185 Sqm
49 49 M&L for providing precast cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate as in string course (kerb stone) with plain fair faces including chamfers, weathering complete all as specified and directed. 6 Cum
50 50 M&L for RCC slab type B-1 (1:2:4) using 20mm graded stone aggregate as in slab supported on walls, MS angle iron frame, beams and columns in floors, roofs, landing as in shelves and the like complete all as specified and directed. 1.8 Cum
51 51 M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landing etc not exc 200 mm thick (horizantal or slopping) for fair finished surfaces of concrete complete all as specified and directed. 18 Sqm
52 52 M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 232 Kg
53 53 M&L for 50mm thick PCC 1:3:6 type C-2 (using 40mm graded aggregate) in plinth protection / padding finishing the surface even and smooth without using extra cement complete all as specified and directed. 120 Sqm
54 54 Demolition of reinforced cement concrete as in cover slabs etc, of any description and in any position otherwise specifically provided directed complete all as specified and directed. 1.8 Cum
55 55 Taking up or down steel water tubing and connection of 15mm bore complete all as specified and directed. 15 RM
56 56 Taking up or down steel water tubing and connection of 20mm bore complete all as specified and directed. 20 RM
57 57 S&F for GI tubing 15mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade complete all as specified and directed. 15 RM
58 58 S&F for GI tubing 20mm bore with all fittings and fixed complete to walls, ceilings or laid in floors medium grade complete all as specified and directed. 20 RM
59 59 S&F in repair bib taps 15mm bore chromium plated fancy type cast copper alloy with crutch of butterfly handle screwed down for iron pipe complete all as specified and directed. 8 Each
60 60 S&F in repair stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions chromium plated and fixed to pipe of 20mm bore complete all as specified and directed. 1 Each
61 61 S&F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed. 8 Each
62 62 Taking down carefully surface aluminium / copper point wiring with wooden battens / PVC conduit (light, fan, socket, bell or power) including fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators etc and making good disturbed surfaces complete all as specified and directed.\n 154 Point
63 63 M&L for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated unsheathed FRLS multistranded copper conductor cable 1.5 sqmm drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories including sunk type pressed steel terminal boxes with 3mm thick bakelite sheet top cover for mounting switches, sockets, fan regulators, including cutting, chasing on wall and other surfaces and making goood disturbed surface in CM 1:3 and finishing the surface as per existing treatment complete all as specified for the following :-
64 63.01 One light / fan / bell / exhaust fan controlled by one switch. 94 Point
65 63.02 One socket outlet 5 pin, 5 amp controlled by one switch on indepdendent board. 16 Point
66 63.03 One socket outlet 5 pin, 5 amp controlled by one switch on the same board. 32 Point
67 64 M&L for point wiring with 1100 volts grade PVC insulated unsheathed FRLS single core multistranded copper conductor cable 2.5 sqmm drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories including sunk type pressed steel terminal boxes with 3mm thick bakelite sheet top cover with earth continuty conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 2.5 Sqmm complete for one switch socket combination 3 pin 15 Amp one no controlled by one switch on independent board, including cutting, chasing on wall and other surfaces and making the good disturbed surface in CM 1:3 and finishing the surface as per existing treatment complete all as specified. 12 Point
68 65 S&F socket outlet 3/6 pin and 15 Amps flush type complete all as specified and directed. 12 Each
69 66 S&F socket outlet 5 pin and 5/6 Amps flush type complete all as specified and directed. 48 Each
70 67 S&F switch piano flush button single pole one way 5 Amp complete all as specified and directed. 142 Each
71 68 S&F switch piano flush button single pole one way 15 Amp complete all as specified and directed. 12 Each
72 69 S&F lamp holder B-22 base insulated body with back plate and connecting up complete all as specified and directed 45 Each
73 70 S&F LED bulb of capacity 15W complete all as specified & directed.\nMake : Havells Cat part No LHLDDEEEML8R015 or equivalent in make as specified in Appx 'B'. 45 Each
74 71 S&F ceiling rose of 65 x 50mm PVC / polycarbonate three terminal surface bakelite complete all as specified and directed. 49 Each
75 72 S&F LED base fixture including 18/20 retro LED tube rod energy saving surface mounted luminaire, high efficiency PMMA diffuser gives soft glare free light environmental friendly, energy efficient ready to use pack complete all as specified and directed. \nMake : Cat Part No SUB 118 T8 LED of Surya or equivalent and tube rod of 18/20W of Cat Part No SLE TL-DS 18P of Surya or equivalent make as specified in Appx 'B'. 34 Each
76 73 S&F electronic ceiling fan regulator stepped type heavy duty suitable to work on 230 volts complete all as specified and directed. 15 Each
77 74 S&F sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar three phase 415 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 confirming to IS-13032, IS-8623, BS-5484 having door earthing complete all as specified and directed. 1 Each
78 75 S&F MCB 63 Amps TPN 415 volts, 16KA 'C' series complete all as specified and directed. 1 Each
79 76 S&F MCB single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10 KA (type 'C') complete all as specified & directed. 30 Each
80 77 S&F MCB SPN, 240 Volts, 32 Amps breaking capacity 10 KA (type 'C' curve) complete all as specified & directed. 4 Each
81 78 S&F sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 suitable for mounting MCB DB confirming to IS-13032, IS-8623, BS-5484 having door earthing complete all as specified & directed.\nNote for item No 74 to 78 : MCBs & MCB DBs shall be of the same make. MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces. 4 Each
82 79 S&F street light fitting LED 20W, pressure die cast aluminium housing & connected with and including 0.5 Sqmm flexible copper multistranded conductor cable including, security light bracket made to shape out of GI pipe 40mm bore light grade, 1.5 mtr length and fixed with MS clamps of size 40 x 5mm - 02 Nos, Nuts, Bolts and washers on wall the light to be fixed on Bldg complete all as specified and directed.\nMake : Havells Cat Part No ENDURAPEARLSL20WLED757SASYTOPC or equivalent of make as apecified in Appx 'B' 3 Each
83 80 M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15mm dia pipe and GI Pipe 20mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) including taking out old existing earthing complete all as specified & directed. 3 Each Set
84 81 M&L Cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; for concealed water tubing etc and making good, cutting exc 10cm but n.exc 20cm girth complete all as specified and directed.\nNote : The cutting of chases will be done using wall chaser / wall groove cutting machine only. 130 RM
85 82 S&F twin core flat 10 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminium multistranded conductor over all PVC sheathed fixed in replacement in service connection complete all as specified and directed. 140 RM
86 83 S&F one star rated energy saving ceiling fans 1200mm sweep as per latest IS-374-2019 having service value = 4 to 4.5m³/min/w and 50 watts with double ball bearing and three blades with all accessories, down rod, two nos canopy, white in colour including 2 core 0.5 Sqmm copper flexible cable for connection from ceiling rose to fan complete all as specified and directed. 20 Each
87 84 Supply, laying, jointing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire, armoured heavy duty electric power cable (heavy duty) with aluminium conductor, 1100 volt grade, cross sectional area of size 16 sqmm 4 core laid in trenches wall / floor etc complete all as specified and as directed. \nNote : Cable may be laid in trenches, under road, across the nallah, along poles / walls and ducts etc. Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid saprately. 100 RM
88 85 Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying cable not exc 10 sqm on plan and n exc 1.5m in depth and getting out complete all as specified and directed. 16 Cum
89 86 Returning filling excavated soil including spreading levelling and well ramming in layers n.exc 15cm thick complete all as specified and directed. 7.5 Cum
90 87 Removing surplus soil to a distance not exceeding 50m & depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 8.5 Cum
91 88 M&L sand filling in trenches with clean dry fine sand unwashed including gently punning around cables 8cm thick before laying & 15cm after laying complete all as specified and directed.\nNote : Punned thickness of sand shall be measured and paid for. 6.5 Cum
92 89 M&L for brick covering to underground electric cable using sub class "B" old size brick laid dry flat per pendicular to the direction of cable complete all as specified and directed. 0.64 Per 1000 Nos
93 90 M&L for replacement of 50 mm bore GI pipe light grade laid in trenches or fixed to wall / pole for protection of cable / earthing strip etc complete all as specified and directed. 20 RM
94 91 S&F and commissioning (maximum energy efficient type) water heater storage type, with 2 KW heating element, electric complete of capacity 25 liters, vertical, metallic body including grouting of studs in wall in CM 1:3 nuts, washers and provision of two numbers PVC connection 600mm long with brass nuts and two number brass chromium plated angular valve suitable for 15mm bore pipe for water supply connection complete all as specified and directed.\nMake : Havells, Monza EC or equivalent makes as specified in Appendix 'B'. 2 Each
95 92 S&F PVC connection 15mm bore best quality of length 450mm, with brass nuts complete all as specified and directed. 4 Each
96 93 M&L for Sub main wiring with 2 single core PVC insulated unsheathed cable, 1100v grade with FRLS PVC 6 Sqmm copper cable multi stranded conductor drawn through in and including PVC rigid non metallic concealed conduit 25mm dia, medium duty, ISI Marked to be terminated in DB box as per IS including of 6 Sqmm dia FRLS PVC insulated unsheathed Copper cable as earth wire connected to earth including taking down old unserviceable sub main wiring complete all as specified & directed.\nNote : Two run of 6 Sqmm cable and one run of 6 Sqmm earth cable and one run of 25mm PVC conduit shall be considered as a unit for measurements purpose. 90 RM