Military Engineer Services-MES has published Routine , Preventive And Corrective Maintenance Of Sewage System For Domestic Area War Memorial Colony , 60 Scientist Hostel And Mes Key Personnel Qtrs Under Ge ( I ) R And D Kanpur. Submission Date for this Tender is 01-02-2021. Sewerage Construction Tenders in GE I R and D Kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: ROUTINE, PREVENTIVE AND CORRECTIVE MAINTENANCE OF SEWAGE SYSTEM FOR DOMESTIC AREA WAR MEMORIAL COLONY, 60 SCIENTIST HOSTEL AND MES KEY PERSONNEL QTRS UNDER GE(I)R&D KANPUR. | |||||
---|---|---|---|---|---|
Sl. No. | Description of item | Item Code / Make | Quantity | Unit | |
1 | 1 | Cleaning of Blockage of internal drainage system of bldgs such as wc gully traps, floor trap nahani trap, soil waste and ventpipe, rain water pipe. Up to Ist manhole and flushing with water and disposal of sludge obtained from cleaning of Blockage out of defence land upto a lead of 2.5 km to 5.00 km. (out of defence land) through a team of skilled safaiwala. Note:- Sludge consist of waste food, waste vegitable, food and human wet night soil complete all as specified and directed. | 1700 | Each | |
2 | 2 | Cleaning of Blockage in sewage line having dia of 100 mm to 150 mm by deplaying of skilled safaiwala by roding, sewage cleanign rod and ball system up to a depth of 1.50 mtr and removing of silt/cached mud/waste obtained from sewage line upto a lead of 2.50 km to 5.00 km complete all as specified and directed. | 280 | RM | |
3 | 3 | All as Per item No. 2.00 here in before but depth of sewer exceeding 1.50 meter but not exceeding 3.00 meter complete all as specified and directed. | 150 | RM | |
4 | 4 | All as Per item No. 3.00 here in before but dia of sewage line exceeding 150mm but not exceeding 300mm dia and depth of sewage line exceeding 3.00meter but not exceeding 4.50meter complete all as specified and directed. | 150 | RM | |
5 | 5 | All as per item No. 4.00 depth of sewage line exceeding 4.50 meter and not exceeding 6.00 meter complete all as specified and directed. | 100 | RM | |
6 | 6 | Preventive and routine cleaning of Manhole through systematic Programme of cleaning/removing of silt accumulation chamber /manholes through a sewer cleaning gang under supervision of competent person including taking all safety precaution. To avoid happening and removal of silt/ cached mud up to distance exceeding 2.5km but not exceeding 5.00km upto depth of manholes upto 1.50meter complete all as specified and directed. | 160 | Each | |
7 | 7 | All as Per item No. 06 here in before but depth of manholes exceeding 1.50 meter but not exceeding 3.00meter complete all as specified and directed. | 70 | Each | |
8 | 8 | All as Per item No. 6 here in before but depth exceeding 3.00meter but not exceeding 4.50meter complete all as specified and directed. | 35 | Each | |
9 | 9 | All as Per item No. 6 here in before but depth exceeding 4.50 meter and above complete all as specified and directed. | 12 | Each | |
10 | 10 | Preventive and routine cleaning of sewer through a systematic programme of cleaning of sewage line through a expert Gang or hydrolic cleaning getting machine up to a depth of 1.50 meter complete all as specified and directed. | 850 | RM | |
11 | 11 | All as Per item No. 10 above but depth exceeding 1.50 meter but not exceeding 3.00meter complete all as specified and directed. | 250 | RM | |
12 | 12 | All as Per item No. 10 above but depth exceeding 3.00 meter but not exceeding 4.50meter complete all as specified and directed. | 100 | RM | |
13 | 13 | All as Per item No. 10 above but depth exceeding 4.50 meter but not exceeding 6.00meter complete all as specified and directed. | 70 | RM | |
14 | 14 | Providing one trolley mounted sewage pump of non clogging type with self proming unit, 6.5 BHP capacity, diesel driven with discharge pipe including fuel, pump operator and pumping out of sewage/sludge effluent from sewage sump (to be used on faulure of existing pumping system) to keep line clear complete all as specified and directed. | 140 | Per Hour | |
15 | 15 | Cleaning of Septic tank/manhole chambers mechanically by opening the covers, removing liquid under any position including foul conditions and cleaning the inlets and outlets etc with water, placing the covers back in position and disposing off the same out side of MD land complete all as specified and as directed. Note : The liquid to be disposed off in sealed tins or sludge removal tankers and the same is deemed to include in the rate quoted. | 180 | Cum | |
16 | 16 | Cleaning of Septic tank/soak pit/ manhole chambers mechanically by opening the covers, removing muck/sludge/silt/mud etc under any position including foul condition and cleaning the inlets and outlets etc with water placing the covers back in position and disposing off the sludge/debris out of MD land complete all as specified and as directed.Note : The sludge to be disposed off in sealed tins or sludge removal tankers and the same is deemed to include in rate quoted | 125 | Cum | |
17 | 17 | Demolition of brick work built in cement mortar as in foul position for manhole and drain etc and removing to a distance exceeding 50 metre but not exceeding 100 metre complete all as specified and directed. | 6 | Cum | |
18 | 18 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed. | 4.5 | Cum | |
19 | 19 | M&L bricks work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall built in cm 1:4 complete all as specified and directed. | 35 | Sqm | |
20 | 20 | Taking down cement plaster of any description,thickness including racking out joints hacking for key scrubbing down with water complete all as specified and directed. | 120 | Sqm | |
21 | 21 | M & L rendering 15mm thick on wall in cement mortar 1:4 on fair faces of brick work or concrete surfaces & finished fair and even smooth without using extra cement complete all as specified and directed. | 150 | Sqm | |
22 | 22 | Demolition of breaking up drain pipes 150mm internal die of pipe (slat glazed ware SWG or reinforced concrete) set in cement mortar including breaking and removal of bedding and hunching complete all as specified and directed. | 151 | RM | |
23 | 23 | S&F 150 mm bore, SGSW Pipe and jointed with cement mortar (1:2) with jute, complete all as specified and directed. | 151 | RM | |
24 | 24 | M&L PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm dia SWG pipe complete all as specified & directed. | 151 | RM | |
25 | 25 | Demolition of breaking up drain pipes 300mm internal die of pipe (slat glazed ware AC or reinforced concrete) set in cement mortar including breaking and removal of bedding and hunching complete all as specified and directed. | 30 | RM | |
26 | 26 | S&F 300 mm bore, SGSW Pipe and jointed with cement mortar (1:2) with jute, complete all as specified and directed. | 30 | RM | |
27 | 27 | M&L PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 300 mm dia SWG pipe complete all as specified & directed. | 30 | RM | |
28 | 28 | Demolition of breaking up drain pipes 100mm internal die of pipe (slat glazed ware AC or reinforced concrete) set in cement mortar including breaking and removal of bedding and hunching complete all as specified and directed. | 50 | RM | |
29 | 29 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. | 50 | RM | |
30 | 30 | M&L PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 110 mm dia PVC pipe complete all as specified & directed. | 50 | RM | |
31 | 31 | S&F 110 mm PVC(SWR) bends any radius complete all as specified and directed. | 4 | Each | |
32 | 32 | M&L PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in surface channels,drains,complete all as specified and directed. | 0.3 | Cum | |
33 | 33 | M&L for precast cement concrete M-15 (nominal) B-O using 12.5mm graded stone aggregate as in cover slab etc. set in cement mortar (1:4) complete all as specified and directed. | 1 | Cum | |
34 | 34 | MS works as in reinforcement using 10mm dia bars and over cut to length bent to shape as required for hoping of column hooking ends and spirally and binding with MS wire annealed not less than 0.90mm dia all as specified and directed. | 50 | Kgs | |
35 | 35 | Taking up or down 15mm dia steel tubing and connections, including cleaning for refixing or removal to store if required complete all as specified and directed | 45 | RM | |
36 | 36 | S&F 15mm bore galvanized iron tubes medium grade with all fitting and fixed complete to walls, ceiling or laid in floor complete all as specified and directed. | 45 | RM | |
37 | 37 | Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal to store if required complete all as specified and directed | 60 | RM | |
38 | 38 | S&F 20mm bore galvanized iron tubes medium grade with all fitting and fixed complete to walls, ceiling or laid in floor complete all as specified. | 60 | RM | |
39 | 39 | Demolition of reinfocement cement concrete cut as in water tank and other RCC similar work required to facilitate and paving not exc.15 cm thickness ( below or above ground level) all as specified. | 3 | Cum | |
40 | 40 | Dismantling water tanks in any type and in any position exc 250 & n. exc 500 ltr capacity complete all as specified and directed. | 10 | Each | |
41 | 41 | S&F 500 Ltr capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. (Make : Sintex, with ISI Marked). | 10 | Each | |
42 | 42 | S&F ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for 20mm dia iron pipe and fixed complete all as specified and directed. (Minimum weight 210gm) | 10 | Each | |
43 | 43 | S & F gun metal globe or gate valve with iron wheel screwed both edns for iron pipe of 20 mm dia complete all as specified and directed. | 10 | Each | |
44 | 44 | S&F 15mm bore stop valve, cast copper alloy, chromium plated (concealed type), screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or fur unions complete all as specified and directed. | 10 | Each | |
45 | 45 | Demolition of cement concrete in ground floor and paving not exc.15 cm thickness ( below or above ground level) complete all as specified and directed. | 2.4 | Cum | |
46 | 46 | M & L for 75mm thick PCC (1:3:6) type C-2 as in plinth protection & finishing the surface even & smooth without using extra cement complete all as specified & directed. | 32 | Sqm | |
47 | 47 | Providing cement concrete 1:2:4 type B-1 in roof kerbs or mud stops,gola, rounded or chamfered on edges,complete all as specified and directed. | 0.3 | Cum | |
48 | 48 | Excavation in trenches n.exc 1.5m deep & n.exc1.5m wide on plan in soft/loose soil and getting out complete all as specified and directed. | 70 | Cum | |
49 | 49 | Excavation in trenches n.exc 1.50 m wide, exc 1.50 m in depth and n. exc 3.00 m in depth on plan in soft/loose soil and getting out complete all as specified and directed. | 41 | Cum | |
50 | 50 | Excavation in trenches n.exc 1.50 m wide, exc 3.00 m in depth and n. exc 4.50 m in depth on plan in soft/loose soil and getting out complete all as specified and directed. | 36 | Cum | |
51 | 51 | Excavation in trenches n.exc 1.50 m wide, exc 4.50 m in depth and n. exc 6.00 m in depth on plan in soft/loose soil and getting out complete all as specified and directed. | 32 | Cum | |
52 | 52 | Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. | 4 | Cum | |
53 | 53 | Removing excavated material n exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. | 6 | Cum | |
54 | 54 | Road curring and making good including baricading etc complete all as specified and directed. | 1 | Each Job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy