Provision Of Kitchen And Toilet Block In 155 Inf Bn ( Ta ) Jak Rif Area At Naya Raipur Mil Stn Under Age ( I ) Naya Raipur, AGE (I) Naya Raipur-Chhattisgarh

Military Engineer Services-MES has published Provision Of Kitchen And Toilet Block In 155 Inf Bn ( Ta ) Jak Rif Area At Naya Raipur Mil Stn Under Age ( I ) Naya Raipur. Submission Date for this Tender is 08-02-2021. Civil Work Tenders in AGE (I) Naya Raipur Chhattisgarh. Bidders can get complete Tender details and download the document.




Tender Notice

26616101
Provision Of Kitchen And Toilet Block In 155 Inf Bn ( Ta ) Jak Rif Area At Naya Raipur Mil Stn Under Age ( I ) Naya Raipur
Open Tender
Indian
Chhattisgarh
AGE (I) Naya Raipur
08-02-2021

Tender Details

Provision Of Kitchen And Toilet Block In 155 Inf Bn ( Ta ) Jak Rif Area At Naya Raipur Mil Stn Under Age ( I ) Naya Raipur

Key Value

Document Fees
INR 500 /-
EMD
INR 19500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : PROVN OF KITCHEN AND TOILET BLOCK IN 155 INF BN (TA) JAK RIF AREA AT NAYA RAIPUR MIL STN UNDER AGE (I) NAYA RAIPUR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Sch 'A' Part-I (Bldg)
2 1.01 Surface dressing n exc 15 cm deep and getting out in soft /loose soil all as specified and directed at site. 40 Sqm
3 1.02 Excavation in trenches not exc 1.5 m wide and n.exc 1.5m in depth in soft/loose soil complete all as specified and as directed. 30 Cum
4 1.03 All as item No 1.02 but depth exc 1.5 to 3.0 Mtr complete all as specified and directed 10 Cum
5 1.04 Returning , filling in spreading and levelling and well ramming in layers not exc 25cm including watering for filling under floor. 27 Cum
6 1.05 Removing of excavated material (soils, etc) to distance n.exc 50 M and depositing where directed at a level n.exc 1.50m above the starting point 13 Cum
7 1.06 M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified. 3.5 Cum
8 1.07 M&L for 25mm thick PCC 1:2:4 type BO (using 12.5mm graded stone aggregate) as in sub floor to receive any type of glazed ceremic tiles complete all as specified. 27 Sqm
9 1.08 M&L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in foundation including rafts, footing, foundation beams, plinth beams, bases for columns, etc and mass concrete all as specified. 10 Cum
10 1.09 M&L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts, etc and mass concrete all as specified. 3 Cum
11 1.1 M&L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in beams, cantilevers, bressumers, lintels over 1.5m span etc. 2.5 Cum
12 1.11 M&L for RCCM-25 (Design mix) (using 20mm graded stone aggregate) as in slabs supported on walls etc. 5.1 Cum
13 1.12 M&L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in Chajja. 0.4 Cum
14 1.13 M&L for PCC 1:2:4 (20mm gradded aggregate) in window cills, steps; seismicand other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed 0.1 Cum
15 1.14 M&L formwork to sides of concrete foundation, footing, bases of columns, rafts and raft beams, sides and plinth beams; and similar work; vertical or to batter, rough finised surface of concrete. 61 Sqm
16 1.15 M&L formwork to sides of concrete of pillars, posts, struts, piers, columns and stanchions all as specified. 37 Sqm
17 1.16 Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide 25 RM
18 1.17 M&L for Formwork to sides of beams, lintels complete all as specified and as directed. 25 Sqm
19 1.18 M&L for formwork to soffits of suspended slabs such as roof slabs, n.exc 200mm thick fair finished concrete surface. 40 Sqm
20 1.19 M&L for Formwork to Chajjas complete all as specified and as directed. 3.5 Sqm
21 1.2 M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spiarally for hooping for columns, plinth beam etc, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia. 650 Kg
22 1.21 Ditto all as above item No 1.20 but 6 to 8 mm -Ditto-. 400 Kg
23 1.22 S&F 5 mm dia and over upto including 10mm dia in stirrups, spacers and binder complete all as specified and directed. 530 Kg
24 1.23 M&L brick work built in CM 1:4 using fly ash modular bricks straight or curved on plan exc 6m mean radius. 16 Cum
25 1.24 M&L brick work built in CM 1:6 using fly ash modular bricks straight or curved on plan exc 6m mean radius. 10 Sqm
26 1.25 M&L damp proof coarses in cement concrete (1:2:4) type type B-0, 40mm thick including necessary form work. 11 Sqm
27 1.26 M&L for soling of Moorum/Red bajri, Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering\nas required 9 Cum
28 1.27 M&L for Hardcore of gauge n exc. 63mm broken stone or boulders, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface 7 Cum
29 1.28 M&L PCC 1:4:8 type D2, 100mm thick (40mm graded aggregate) as in sub base, sub floors and pavings, etc. 29 Sqm
30 1.29 M&L for cement concrete 1:3:6 type C2, 75mm thick as in plinth protection. 11 Sqm
31 1.3 M&L for machine cut kota stone slab flooring 20-25 mm thick over 20 mm thick screed bed in cm 1:6 laid and jointed in cement slurry mixed with pigment to match the shade of slab including rubbing and polishing all as specified and directed. 22 Sqm
32 1.31 M&L machine cut kota stone slab 20-25 mm thick for skirting laid over 10 mm thick cement mortar (1:4) and jointed in cement slurry mixed with pigment to match the shade of slab including rubbing and polishing all as specified and directed. 2 Sqm
33 1.32 M&L rendering 15mm th plaster in CM 1:6 on fair faces of brick or concrete surfaces finished fair and even without using extra cement complete all as specified and as directed. 85 Sqm
34 1.33 M&L for two coat of oil bound emulsion distemper incl prepration of new plastered surface of wall over a coat of primer complete all as specified. 85 Sqm
35 1.34 M&L for rendering 15 mm thick plaster in CM (1:4) on brick or concrete surface in two layer of 10mm and 5mm thick each. Second coat of 5mm thick with water proofing compound as per manufacturer instruction finished fair & even all as directed (WPC shall be measured and paid separately). 80 Sqm
36 1.35 M&L rendering 5 mm th in CM 1:3 as in ceiling finished fair and even without using extra cement. 40 Sqm
37 1.36 M&L for three coat of white washing on ceiling including preparation of surfaces complete all specified and as directed. 40 Sqm
38 1.37 M&L preparing surface plastered or unplastered on wall with two coats of Cement base paint over a coat of alkali resistant primer paint with complete all as specified and directed. 80 Sqm
39 1.38 M & L for 5mm thick cement plaster 1:4 over roof slab mixed with water proofing compound complete all as specified and as directed. 36 Sqm
40 1.39 Supply only integral water proofing compound complete all as specified and as directed 55 Kg
41 1.4 M&L for cleaning the top surface of concrete and providing water proofing treatment with polymeric water proofing memberane not less than 3.0 Kg/Sqm such as M/S Tikki tar /STP/ SUPER HYDRA-310 /Equivalent of approved make test to be carried out from national test hous/Govt lab ,for all makes, including priming the surface by applying bituminous primer @ 0.3 Kg/sqm and applying the surface by blown grade bitumen 85/25 @ 1.20 Kg/Sqm & applying water proofing memberane( with 10 cm. overlaps )and applying the surface by blown grade bitumen 85/25 @ 1.20 Kg/Sqm and painting bituminuos aluminium paint @ 100gm/sqm all as specified & directed. 40 Sqm
42 1.41 M&L non skid coloured ceramic tiles 7 to 8 mm thick(square/rectangular) area of each tiles exceeding 0.06 sqm but n.exc 0.11sqm in floor etc,over 15 mm thick screed bed in CM(1:6),set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and directed. 7 Sqm
43 1.42 M&L for coloured glazed ceramic tiles in vertical surface 300x200x5to6mm thick over10 mm thick cement plaster in CM (1:4); set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces all as specified and directed 3 Sqm
44 1.43 S&F pressed steel frames for doors size 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified. 11 RM
45 1.44 S&F 500 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed 2 Each
46 1.45 Cutting chases, pining in making good to facing on required and pointing in cm (1:3) to ends or edges of sunshades,shelves and cutting chases for concealed water tubing in wall and making good cutting not exc 10 cm girth. 10 RM
47 1.46 S&F GI tubing medium grade with all fitting and fixed to wall ,ceiling or laid in floor etc complete of 15 mm bore pipe. 10 RM
48 1.47 Ditto-all as per item No 1.46 but 20 mm bore 15 RM
49 1.48 S&F for 20mm bore stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed. 3 Each
50 1.49 S&F for 15mm dia angle stop valves cast copper alloy feney type,chromium plated complete all as specified and directed. 2 Each
51 1.5 S&F for 15mm bore, bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed. 3 Each
52 1.51 S&F for vitrious china wash basin, white flat back size 550x400mm including waste, chain & plug andporeclain stopper and bracket etc. Complete including cutting for and pinning in ends of brackets or errecting bracket and 32mm dia waste fitting brass chromium plated etc;with long screwed shanks and fly nuts,flange end bedded in red lead cement including 32mm dia waiste pipe fitted complete all as specified and directed. 1 Each
53 1.52 S&F PVC connection pipe 45 cm long with PTMT fixed to WHB, flushing cistern an complete all as directed at site. 2 Each
54 1.53 S&F 75 mm dia outlet PVC (SWR) floor trap plain with steel grating including jointing with solvent cement. 2 Each
55 1.54 S&F for vitreous china squatting pan “Orissa” pattern, size 580 X 440 mm, white with integral foot rest,and "P" or "S" trap (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe etc. all as specified and as directed. 1 Each
56 1.55 S&F for PVC flushing cistern, 10 ltrs capacity with inlet, ball valve, float and handle, including bracket and 38mm dia flush pipe of polyethylene for low level cistern complete all as specified and as directed. 1 Each
57 1.56 S&F for 600mm x 450 mm bevelled edge mirror of selected quility glass, mounted on 6 mm thick commercial ply wood and fixed to wooden plugs with chromium plated brass screwes and cup washers complete. 1 Each
58 1.57 M&L brass chromium plated tubular towel rail 20mm dia D type 600 mm long between flanges fixed Complete all as specified and directed. 1 Each
59 1.58 M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed. 3 RM
60 1.59 M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints,laid in trenches or in floors complete all as specified & directed. 3 RM
61 1.6 M&L PVC (SWR) bend any radius 110mm dia 1 Each
62 1.61 M&L PVC (SWR) bend any radius 75mm dia 1 Each
63 1.62 M&L PVC(SWR) Tee any radius 110mm dia 1 Each
64 1.63 M&L PVC(SWR) Vent cowl 110mm dia 1 Each
65 1.64 S&F factory made solid panel PVC door shutter 30 mm thick consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheets strl of 20 mm width stock inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail and bottom rail on either side and as gap inside for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame weided/seated to the stiles and rail with suitable PVC sheet bending and jointed to gether with solvent cement supplying and fixing in the frame at site as per specification and drawing Make : Rajshree/Sintax. 5 Sqm
66 1.65 S&F solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube S&F in opening as per specification drawings. 15 RM
67 1.66 S&F 200 mm long aluminum anodized barrel tower bolt extruded section. 2 Each
68 1.67 S&F aluminum handles cast type anodize 150 mm long. 6 Each
69 1.68 S&F extruded aluminium alloy butt hinges 100mm size type B-21 all as specified & directed. 9 Each
70 1.69 M/L for 2nd class hard wood plain,solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints supplied and fixed. 0.02 Cum
71 1.7 M/L for 35mm thick 2nd class HW rail and style plain framed, factory made paneled shutter (one panel) without interlocking rail and 12mm veneered particle board with commercial veneering on both faces the size of rail and style as per IS -1003 (Pt-I)kiln seasoned and chemically pressure treated complete all as specified and directed. 4 Sqm
72 1.71 S&F 2nd class HW glazed and skelton 35mm thick shutters, open rebated and prepared to receive glass gauze etc (with out sash bars) edges of framing plain, chamfered or rounded, fitted with cut and metered beads for securing glass. Gauze etc and all as specified in SSR and fitted to chowkhats 2 Sqm
73 1.72 S&F mild steel works as in small articles like hold fasts, conforming to Fe-290 or Fe E-165 complete all as specified and directed. 2 Kg.
74 1.73 S&F factory made steel windows with side hung shutters including box type hinges with steel handle and steel peg stay complete with glasing bars dovetail.ed or welded all as specified and directed. 4.3 Sqm
75 1.74 All as per item No 1.73 here-in before but without glazing bars 4.3 Sqm
76 1.75 S&F factory made steel ventilators with top hung shutter including hinges,steel peg stay complete all as specified and directed. 0.5 Sqm
77 1.76 S&F frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks conforming to Fe-290 Gd E-165 complete all as specified and directed. 18 Kg
78 1.77 S&F galvanised steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in repairs complete all as directed at site. 2 Sqm
79 1.78 S&F sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane thickness of glass 3mm.thick all as directed at site 3 Sqm
80 1.79 .- Ditto- all as per above item No 1.78 but n.exe 0.5 sqm in each 3mm figured glass. 1 Sqm
81 1.8 S&F in MS sliding door bolts 300mm long plate type stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bold plate and two on staple plate and fixed complete all as specified and directed. 3 Each
82 1.81 S&F 300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and direcetd. 1 Each
83 1.82 M&L applying two coat of synthetic enamelled paint over one coat of pink primer on wooden surfaces of any description not otherwise described over 10cm width or girth including preparation of surface complete all as specified and directed. 10.5 Sqm
84 1.83 M&L for preparing the newly surface of any description not otherwise described over 10 cm width or girth on steel surface and applying two coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and directed. 6 Sqm
85 1.84 M&L 20-25 mm thick cuddapa prepolished stone over and including 10 mm thick cement mortar (1:4) bedding laid & jointed with slurry cement mixed with pigment to match the shade of the slab including rubbing and polishing,rounding to edge of stone slab one edge,such as steps,cooking plateorm and similar situtions complete all as specified.(Note-Hole in stone slab for accomodate the gas pipe where required complete. 8 Sqm
86 1.85 S&F sinks with drainage board made of stainless steel lmm thick\nkitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete. 1 Each
87 1.86 S&F in repair pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and flynuts, screwed for iron pipes and fixed for 15mm dia complete all specified and directed. 1 Each
88 1.87 S&F in repair 15mm bore Brass cp wall mixer for mixing hot & cold water screwed down , for iron pipe or for brass ferrule complete. 1 Each
89 2 Sch 'A' Part-II (Sewage Disposal)
90 2.01 Excavation in trenches n,exc 1.5m wide and 1.5m deep for fdn of manhole and getting out in soft/loose soil complete all as specified and directed. 4 Cum
91 2.02 Excavation over areas n. exc. 1.5m depth for fdn, etc., and getting out in soft and loose soil complete all as specified and directed. 15 cum
92 2.03 Excavation over areas exc. 1.5m depth but n. exc 3m in depth for fdn, etc., and getting out in hard/dense soil complete all as specified and directed. 13 cum
93 2.04 Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm deep as in soil complete all as specified. 9 Cum
94 2.05 Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. 20 Cum
95 2.06 PCC 1:4:8 type D2 using 40mm graded stone aggregate in fdn filling and mass concrete 2 Cum
96 2.07 M&L for PCC 1:2:4 type B1 as in coping complete all as specified. 0.5 Cum
97 2.08 M&L for PCC 1:2:4 type B2 as in surface channels complete all as specified. 0.25 Cum
98 2.09 M&L brick work built in CM 1:4 using fly ash modular bricks straight or curved on plan exc 6m mean radius. 6.5 Cum
99 2.1 M & L for Brickwork with fly ash bricks in one brick thick honey-comb walling, built in CM 1:6 cmplete all as specified and directed 25 Sqm
100 2.11 M&L for precast manhole covers with plain faces using RCC 1:2:4 type B1 and set in CM 1:4 including formwork 0.3 Cum
101 2.12 TMT steel bars 10mm dia and over cut to length bent to shape required incl cranking bending spirally for hooping for columns, hooking ends and binding with and incl MS wire (annealed) not less than 0.9mm dia or securing with clips 10 Kg
102 2.13 S&F TMT steel bars 6 to 8 mm dia and over, as in reinforcement for concrete, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and directed. 130 Kg
103 2.14 Supply and laying double wall corrugated DWC pipe HDPE pipe of outer dia 175mm and inner dia 147mm of approved make ISI marked polythene with smooth internal wall & profiles external surfaces for non pressure for sewage complete all as specified. 3 RM
104 2.15 Extra for forming fair finished channel or drain 30cm girth (inner girth) in cement concrete using extra cement incl forms, moulds, stopped 3 RM
105 2.16 M&L for 15mm thick rendering in CM 1:4 on concrete surfaces finished even and smooth without using extra cement incl water proofing compound.\n(Note:- Water proofing compound will be measured and paid seperately) 25 sqm
106 2.17 Supply only water proofing compound. 7.5 Kg
107 2.18 Precast RCC 1:11/2:3 type A1 (using 20 mm graded stone aggregate) set in CM 1:4 as in cover slabs. 1.25 Cum
108 2.19 M&L for CI Soil waste and vent pipe 100 mm bore 2 RM
109 2.2 M&L for CI vent Cowl 100 mm bore 1 Each
110 2.21 M&L for broken stone or boulders, Loose filling with aggregates of gauge 15 to 80mm in soakage pits as shown in drawing. 2 cum
111 3 Sch 'A' Part-III (Internal Electric)
112 3.01 M&L Point wiring complete with 1.5 sqmm PVC insulated stranded copper conductor single core cable drawn through and including rigid non metalic PVC conduit 20 mm dia ( meadium grade ) , ISI marked with concealed conduit wiring including cutting chases and making good in CM 1:3 & white/colour wash to match existing surface, pressed steel terminal boxes not less than 1.6 mm thick concealed in wall duly painted with two coat of black bituminous paint over a coat of red oxide primer, plastic laminated top sheet cover 2.8 mm thick of required size and colour for housing switches and sockets, 1.5 sqmm PVC insulated (green insulation) copper conductor as earth continuity cable drawn with wiring and connected to common earth dolly all as specified for -
113 3.02 (a) One light point/fan point controlled by one switch 34 Per Point
114 3.03 (c) One socket out let 5 pin 5 Amp on same board 4 Per Point
115 3.04 (d) s/scocket combination 5 pin on independent board 8 Per Point
116 3.05 All as per item No 03 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable for 3/6 pin 5 & 15 Amp socket outlet controlled by one switch on independent board with and including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed. 8 Per Point
117 3.06 M&L for submain wiring with 2 Run of 6 Sqmm PCV insulated and unsheathed stranded copper conductor cable and 4.00 sqmm copper cable of green colour as a earth wiring of drawn into and inclu PVC conduit 20mm dia and accessaries complete as specified. 96 RM
118 3.07 S&F Switch piano flush type polycarbonate , Single pole, one way, 6 amps, 230 Volts, specified make 38 Each
119 3.08 S&F socketoutlet 2in 1-5 pin , Single pole,polycarbonet one way, 6 amps, 230 Volts, specified make 4 Each
120 3.09 S&F s/socket outlet 2 in 1 5 pin combination polycarbonet, Single pole, one way, 16 amps, 230 Volts, specified make 8 Each
121 3.1 S and fix independent board 5 pin S/Socket combination 6 Amps all as per required. 8 each
122 3.11 S/F Ceiling rose surface type bakelite, two or three terminal 14 Each
123 3.12 S/F ceiling fan regulator 120 volts 4 Each
124 3.13 S & F MCB DB epoxy powder coated distribution box SPN, 8 ways, 240 volts, for MCB double door , grouted flush to walls with IP 43 and metal door complete all as specified and directed. 1 Each
125 3.14 S & F MCB DB epoxy powder coated distribution box SPN, 4 ways, 240 volts, for MCB double door , grouted flush to walls with IP 43 and metal door complete all as specified and directed. 1 Each
126 3.15 S & F MCB DB epoxy powder coated distribution box TPN, 4 ways, 240 volts, for MCB double door , grouted flush to walls with IP 43 and metal door complete all as specified and directed. 1 Each
127 3.16 S & F SP, 6 to 32 Amps, 240 Volts , 10 KA , 'c' curve MCBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating). 8 Each
128 3.17 S & F SPN, 32 Amps, 240 Volts , 10 KA , 'c' curve MCBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating). 5 Each
129 3.18 S & F TPN, 32 Amps, 415 Volts , 16 KA , 'c' curve MCBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating). 1 Each
130 3.19 Supply and fixing Wall mounting indoor decorativeLED T-8 batten with opel diffuser 1x 18/20 W LED tub light mounting over two nos of round wooden blocks complete with , tube and all accessories making electrical connections with twin core PVC flexible copper wire of size 0.50 sqmm upto 1.5 mtr length complete. Make - Philips/Wipro / Oshram 6 Each
131 3.2 Supply & Fixing exhaust fan 300mm sweep metal body type 240 volts complete all as specified and directed. Make Orient/USHA/CG 2 Each
132 3.21 Supply and fix recess mounted ceiling light 2'x2' 35 watt any type with all fixing arrangement ,all as per required and directed by engg in chrge Make Wipro / Philips /Oshram 2 Each
133 3.22 Supply and fix building security light of 35watt IP 65 watt,LED die casting aluminium with LED street optic lenses ,efficacy of skyline plus is upto 120lm/w, with pea nut lenses LED type with bracket arrangement all as per required and directed by Engg in Chrge MAke - Wipro / Philips/Oshram 6 each
134 3.23 Supply & Fixing ceiling fan 1400mm sweep metal body type 240 volts complete all as specified and directed. Make Orient/USHA/CG 2 Each
135 4 Sch 'A' Par-IV (External Elect Supply)
136 4.01 Supply/Laying or fixing or passing through pipe, jointing and testing 1100 volt grade XLPE insulated armoured heavy duty PVC insulated, PVC sheathed armoured electric cables with aluminum stranded conductor, 16 sqmm 2 core complete all as specified and as directed. \n 40 RM
137 4.02 Supply/Laying or fixing or passing through pipe, jointing and testing 1100 volt grade XLPE insulated armoured heavy duty PVC insulated, PVC sheathed armoured electric cables with aluminum stranded conductor, 16 sqmm 4 core complete all as specified and as directed. \n 70 RM
138 4.03 Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out for laying of pipe cables etc,. and getting out complete all as specified and directed 22.95 Cum
139 4.04 Returing filling in, including spreading levelling, watering and well ramming in layers not exceeding 25cm thick with earth obtained from excavation complete all as specified and as directed. 15.624 Cum
140 4.05 Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. 8.14 Cum
141 4.06 Material and labour for dry river washed and screened dry sand for filling in trenches below and around the cable for cushioning including punning down as specified in relevant clause of SSR Part I.\nNote:- Punned thickness shall only be measured and paid. 6.885 Cum
142 4.07 Supply and lay bricks sub class 'B' laid dry abutting each other with gap between adjacent slab not exceeding 10mm over UG cable as in cable protection all as directed. 680 each
143 4.08 Material and labour 40 mm thick cement concrete for PCC 1:2:4, type B1 using (20 mm graded)in floor finish even and smooth without using extra cement including necessary work complete as all specified and as directed. 10 Sqm
144 4.09 Material and labour for earthing complete with galvanised steel plate earth electrode 600 X 600 X 6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected with 4 mm galvanised steel wire at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/ dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6, type C-I, using 20mm grade stone aggregate and MS angle iron frame 40 x 40 x 6mm, RCC 1:2:4, type B-1, using 20mm grade stone aggregate, 50mm thick pit cover, reinforced with 8mm dia TMT bars, 75mm centre to centre both ways, MS handle 12mm dia, PGI funnel, wire mesh and GI pipe of 20mm bore (light grade) and earth lead protection pipe 15mm bore (light grade) and all as shown in electrical plate No. 3 of SSR Part-I including testing complete all as specified and directed. \nNote:- GI wire and protection pipe up to 7.5 metre beyond the earth plate electrode is included in unit rate quoted. 1 Each
145 5 Sch 'A' Part-V (External Water Supply)
146 5.01 M and L for laying 25 mm medium grade steel water tubing all as required and directed. 50 RM
147 5.02 M&L for gate valve brass type 25 mm all as required and directed. 3 each
148 5.03 Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out for laying of pipe cables etc,. and getting out complete all as specified and directed 4.8 Cum
149 5.04 Returing filling in, including spreading levelling, watering and well ramming in layers not exceeding 25cm thick with earth obtained from excavation complete all as specified and as directed. 4.2 Cum
150 5.05 Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. 0.6 Cum
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy