Repair , Maintenance And Improvement To External Electrification Networks In Technical Area And Connected Works At Airforce Station Thanjavur, THANJAVUR-Tamil Nadu

Military Engineer Services-MES has published Repair , Maintenance And Improvement To External Electrification Networks In Technical Area And Connected Works At Airforce Station Thanjavur. Submission Date for this Tender is 30-01-2021. Electrification Work Tenders in THANJAVUR Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

26613838
Repair , Maintenance And Improvement To External Electrification Networks In Technical Area And Connected Works At Airforce Station Thanjavur
Open Tender
Indian
Tamil Nadu
THANJAVUR
30-01-2021

Tender Details

Repair , Maintenance And Improvement To External Electrification Networks In Technical Area And Connected Works At Airforce Station Thanjavur

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR, MAINTENANCE AND IMPROVEMENT TO EXTERNAL ELECTRIFICATION NETWORKS IN TECHNICAL AREA AND CONNECTED WORKS AT AFS THANJAVUR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply and fix in replacement Off load change over switch 400 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handle operated complete all as directed . Make :- Havells/ABB/Control & switchgear 2 Each
2 2 Supply and fix in replacement Off load change over switch 320 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handle operated complete all as directed Make :- Havells/ABB/Control & switchgear 2 Each
3 3 Supply and fix in replacement Off load change over switch 200 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handle operated complete all as directed by Engr In Charge. Make :- Havells/ABB/Control & switchgear 2 Each
4 4 Supply and fix in replacement Off load change over switch 100 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handle operated complete all as directed. Make :- Havells/ABB/Control & switchgear 4 Each
5 5 Supply and fix in replacement On load change over switch 200 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated complete all as directed . Make :- Havells/ABB/Control & switchgear 1 Each
6 6 Supply and fix in replacement On load change over switch 160 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated complete all as directed Make :- Havells/ABB/Control & switchgear 1 Each
7 7 Supply and fix in replacement On load change over switch 125 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated complete all as directed . Make :- Havells/ABB/Control & switchgear 1 Each
8 8 Supply and fix in replacement On load change over switch 100 amps 415 volts 4 pole 50 Hz open execution type with rotary type handle operated complete all as directed . Make :- Havells/ABB/Control & switchgear 1 Each
9 9 Supply and fix in replacement MCCB 4 pole adjustable type 630 amps ruptering capacity 36 KA for 415 volts complete as directed by Engr In Charge. Make :- Havells/ABB/Legrand/L&T 1 Each
10 10 Supply and fix in replacement MCCB 4 pole adjustable type 400 amps ruptering capacity 36 KA for 415 volts complete as directed by Engr In Charge. Make :- Havells/ABB/Legrand/L&T 4 Each
11 11 Supply and fix in replacement MCCB 4 pole adjustable type 320 amps ruptering capacity 36 KA for 415 volts complete as directed by Engr In Charge. Make :- Havells/ABB/Legrand/L&T 2 Each
12 12 Supply and fix in replacement MCCB 4 pole adjustable type 250 amps ruptering capacity 36 KA for 415 volts Ics = 100% Icu complete as directed by Engr In Charge. Make :- Havells/ABB/Legrand/L&T 6 Each
13 13 Supply and fix in replacement MCCB 4 pole adjustable type 200 amps ruptering capacity 36 KA for 415 volts Ics = 100% Icu complete as directed by Engr In Charge. Make :- Havells/ABB/Legrand/L&T 8 Each
14 14 Supply and fix in replacement MCCB 4 pole adjustable type 160 amps ruptering capacity 25 KA for 415 volts Ics = 100% Icu complete as directed by Engr In Charge. Make :- Havells/ABB/Legrand/L&T 8 Each
15 15 Supply and fix in replacement MCCB 4 pole adjustable type 100 amps ruptering capacity 25 KA for 415 volts Ics = 100% Icu complete as directed by Engr In Charge. Make :- Havells/ABB/Legrand/L&T 8 Each
16 16 Supply and fix in replacement MCCB 4 pole adjustable type 63 amps ruptering capacity 25 KA for 415 volts Ics = 100% Icu complete as directed by Engr In Charge. Make :- Havells/ABB/Legrand/L&T 10 Each
17 17 Supply and fix in replacement MCCB 4 pole adjustable type 32 amps ruptering capacity 25 KA for 415 volts Ics = 100% Icu complete as directed by Engr In Charge. Make :- Havells/ABB/Legrand/L&T 4 Each
18 18 Supply and fix in replacement industrial busbar chamber in sheet metal enclosure TPN 415 volts 63 amps wall mounted 8 way complete all as specified and as directed by Engr In Charge. Make :- Havells/ABB/Legrand/L&T 5 Each
19 19 Supply and fix in replacement industrial busbar chamber in sheet metal enclosure TPN 415 volts 100 apms wall mounted 8 way complete all as specified and as directed by Engr In Charge. Make :- Havells/ABB/Legrand/L&T 5 Each
20 20 Disconnecting the input and output electric supply from automatic voltage stabiliser of any capacity and taking out from site and shifting to civil workshop.\nNote:- The rate quoted by the contractor shall incude the rate for T&P, transportation and necessary men power required during loading and unloading. 1 Each Job
21 21 Opening the top cover of votage stabiliser taking out the complete servo stabilizer oil and keep it for reuse and taking out dimmer assembly and transformer assembly for checking the defects and carrying out the following repairs:- 1 Each Job
22 22 Supply and fix in replacement Dimmerstate unit of capacity 25 KVA servo voltage stabilizer 20 amps of Make Volina complete all as specified and directed. 1 Each
23 23 Supply and fix in replacement main transformer of capacity 25 KVA servo voltage stabilizer of make Volina complete all as specified and directed. 1 Each
24 24 Supply and fixing in replacement Electronic circuit board (Printed circuit board) for controlling of synchronous motor of torque 10 KG and auto/manual under voltage high voltage operation. 2 Each
25 25 Supply and fix in replacement PCB holder.complete all as specified. 2 Each
26 26 Supply and fixing in replacement trigger transformer.complete all as specified. 2 Each
27 27 Supply and fixing in replacement panel lamps alongwith connecting leads for over voltage under voltage etc.complete all as specified. 6 Each
28 28 Supply and fix in replacement corbon brush.complete all as specified. 2 Each
29 29 Supply and fix in replacement digital volt meter 72 x 72mm.complete all as specified. 3 Each
30 30 supply and fixing in replacement servo motor 10 KG torque.complete all as specified. 1 Each
31 31 Supply and fixing in replacement RC network for 10 KG servo motor.complete all as specified. 2 Each
32 32 Supply and fix in replacement auto manual switch.complete all as specified. 2 Each
33 33 Supply and and fixing in replacement LT heat shrink straight throught jointing kit suitable for 6 to 16 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed by Engr In Charge. 10 Each
34 34 Supply and and fixing in replacement LT heat shrink straight throught jointing kit suitable for 25 to 50 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed by Engr In Charge. 5 Each
35 35 Supply and and fixing in replacement LT heat shrink straight throught jointing kit suitable for 70 to 150 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed by Engr In Charge. 5 Each
36 36 Supply and and fixing in replacement LT heat shrink straight throught jointing kit suitable for 185 to 300 sqmm 3.5/4 core PVC/XLPE cables 1.1 KV grade complete all as specified and as directed by Engr In Charge. 2 Each
37 37 Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft /loose soil.complete all as specified. 200 SQM
38 38 M&L hard core of guage not exe 63mm deposited spreaded and levelled in layers not exe 16cm thick watered and well rammed to a true surface.complete all as specified. 15 Cum
39 39 Cement concrete in foundations, and mass concrete type C1 1:3:6 using 20mm graded stone aggregate.complete all as specified. 30 Cum
40 40 Taking out hanging doors from LT panels welding the doors in position by using new hinges and scrapping old surface and cleaning smoothly and applied two coats of synthetic enamel paint over a coat of red oxide primer and freshening of damaged insulation of cables including excavation and earth work for removing of loop of cables etc complete all as specified and as directed by Engr In Charge. 50 Each Job
41 41 Supply and fix in replacement HBC fuse link 40 to 160 amps complete all as specified and as directed. 5 Each
42 42 Supply and fix in replacement DN open type fuse bases fixed type 100 to 160 amps complete all as specified and as directed. 5 Each
43 43 Supply, Laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 10 sqmm 2 core with all fixing & connecting accessories including taking down old unserviceable cable.\nMake: Havell’s / Polycab / Finolex) 400 RM
44 44 All as per Item No 43 here-in-before but 16 sqmm 2 core Make: Havell’s / Polycab / Finolex) 600 RM
45 45 All as per Item No 43 here-in-before but 16 sqmm 4 core Make: Havell’s / Polycab / Finolex) 2000 RM
46 46 All as per Item No 43 here-in-before but 25 sqmm 3.5 core Make: Havell’s / Polycab / Finolex) 1000 RM
47 47 All as per Item No 43 here-in-before but 35 sqmm 3.5 core Make: Havell’s / Polycab / Finolex) 1000 RM
48 48 All as per Item No 43 here-in-before but 50 sqmm 3.5 core Make: Havell’s / Polycab / Finolex) 350 RM
49 49 All as per Item No 43 here-in-before but 95 sqmm 3.5 core (Make: Polycab/Havell’s/Plaza) 300 RM
50 50 All as per Item No 43 here-in-before but 120 sqmm 3.5 core Make: Havell’s / Polycab / Finolex) 300 RM
51 51 Supply and fixing/laying in replacement 80 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laing in trench or pole / wall for protection of cable complete all as specified and as directed.(Make : TATA/JINDAL/Zenith) 60 RM
52 52 Supply and fixing/laying in replacement 50 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laing in trench or pole / wall for protection of cable complete all as specified and as directed.(Make : TATA/JINDAL/Zenith) 60 RM
53 53 Supply and fixing/laying in replacement 40 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laing in trench or pole / wall for protection of cable complete all as specified and as directed.(Make : TATA/JINDAL/Zenith) 60 RM
54 54 Material and labour in replacement of alluminium cable thimbles/line connectore/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 120 Sqmm UG Cable including complete connection and crimping. Make ; Jaipuriya/Rastriya/Dowells 60 Each
55 55 All as per Item No.54 above but 95 Sqmm. 60 Each
56 56 All as per Item No.54 above but 50 Sqmm. 50 Each
57 57 All as per Item No.54 above but 35 Sqmm. 60 Each
58 58 All as per Item No.54 above but 25 Sqmm. 30 Each
59 59 All as per Item No.54 above but 16 Sqmm. 30 Each
60 60 All as per Item No.54 above but 10 Sqmm. 30 Each
61 61 Supply and fixing cable glands 10 sqmm complete all as directed by Engr In Charge. 40 Each
62 62 Supply and fixing cable glands 16 sqmm complete all as directed by Engr In Charge. 30 Each
63 63 Supply and fixing cable glands 25 sqmm complete all as directed by Engr In Charge. 20 Each
64 64 Supply and fixing cable glands 35 sqmm complete all as directed by Engr In Charge. 16 Each
65 65 Supply and fixing cable glands 50 sqmm complete all as directed by Engr In Charge. 20 Each
66 66 Supply and fixing cable glands 95 sqmm complete all as directed by Engr In Charge. 20 Each
67 67 Supply and fixing cable glands 120 sqmm complete all as directed by Engr In Charge. 7 Each
68 68 Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed.\nNote :- Mechanical excavation is not allowed in this Stn only manual excavation allowed. 1150 CUM
69 69 Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note:- Excavated soil shall be riddled by using sieve to separate composite partricles etc as per IS 1255 1983 and refilling in trenches as in cable cushioning. 521 CUM
70 70 Removing surplus soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point all complete as specified and as directed. 629 CUM
71 71 Supply and laying Bricks, sub class 'B' old size bricks, laid flat dry with width of the bricks laid to the axis of the cable all complete as specified and as directed. 41 Per 1000 Nos