Airports Authority Of India has published Comprehensive Maintenance Contract For Ac Units , Water Coolers And Purifiers At Rajahmundry Airport. Submission Date for this Tender is 19-01-2021. Tape Supply Tenders in Airports Authority of India, Rajahmundry Airport Andhra Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: ARMO of E&M Installations at Rajahmundry Airport for the year 2020-21. Sub Head: Comprehensive Maintenance Contract for AC Units, Water Coolers and Purifiers at Rajahmundry Airport. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Comprehensive Maintenance of Air conditioning units, water coolers and water purifiers of following rating and capacity of various makes at different locations including routine & preventive maintenance, breakdown repairs & servicing and providing all necessary consumables and spares etc. complete as required as per special conditions of the contract and inventory details (Prefilters, Post filters and Membarane as required for water purifiers shall be provided by AAI) | |||
2 | 1.01 | 1.5/2 TR Single phase Split type / Inverter Split type / Cassette type AC units.\n\nNote: Out of 68 Nos., 42 Nos. AC units are installed in the year of 2020. These 42 Nos. AC Units are under guarantee period/Defects Liability Period up to 31.08.2021. These 42 Nos AC units will be handed over w.e.f. 01.09.2021. Payment shall not be made up to 31.08.2021 for 42 Nos. AC units. | 1 | 68 | Each per year |
3 | 1.02 | 3TR/4 TR Three phase Split type / Inverter Split type / Cassette type AC units / Vertical Split type AC units.\n\nNote: Out of 24 Nos., 11 Nos. AC units are installed in the year of 2020. These 11 Nos. AC Units are under guarantee period/Defects Liability Period up to 31.08.2021. These 11 Nos AC units will be handed over w.e.f. 01.09.2021. Payment shall not be made up to 31.08.2021 for 11 Nos. AC units. | 2 | 24 | Each per year |
4 | 1.03 | 40 LPH capacity(Make & Model: Blue Star SDLX 480), 80 ltrs storage type Single phase Water Cooler cum dispenser | 3 | 5 | Each per year |
5 | 1.04 | 125 LPH capacity (Make & Model:CONWAY D 125 WHC) Warm(30 ltrs) , Cold (40 ltrs), Hot(05 ltrs) water storage type Single phase Water Cooler cum dispenser.\n\nNote: 15 Nos. above Water Cooler cum dispenser units are installed in the year of 2020. These 15 Nos. Units are under guarantee period/Defects Liability Period up to 31.08.2021. These 15 Nos. units will be handed over w.e.f. 01.09.2021. Payment shall not be made up to 31.08.2021 for 15 Nos. units. | 4 | 15 | Each per year |
6 | 1.05 | 25 LPH Capacity, RO+ UV based Water purifier which is inbuilt with the above model CONWAY D 125 WHC water cooler cum dispenser including replacement of all departmentally provided pre & post filters, membarane once in a year.\n\nNote: 15 Nos. above Water Purifiers units are installed in the year of 2020. These 15 Nos. Units are under guarantee period/Defects Liability Period up to 31.08.2021. These 15 Nos. units will be handed over w.e.f. 01.09.2021. Payment shall not be made up to 31.08.2021 for 15 Nos. units. | 5 | 15 | Each per year |
7 | 1.06 | 20 LPH and 8 Ltr Storage Capacity, wall mounted RO+ UV based Water purifier (Kent Grand+) i including replacement of all departmentally provided pre & post filters, membarane once in a year. | 6 | 5 | Each per year |
8 | 2 | Supply of Water purifier filters suitable for 25 LPH Capacity, RO+ UV based Water purifier which is inbuilt with the above model CONWAY D 125 WHC water cooler cum dispenser. | |||
9 | 2.01 | 10" spun candle filter | 7 | 15 | Each |
10 | 2.02 | 10" carbon block | 8 | 15 | Each |
11 | 2.03 | Membrane | 9 | 15 | Each |
12 | 2.04 | Sediment filter | 10 | 15 | Each |
13 | 2.05 | Post carbon | 11 | 15 | Each |
14 | 3 | Supply of Water purifier filters suitable for 20 LPH and 8 Ltr Storage Capacity, wall mounted RO+ UV based Water purifier (Kent Grand+) | |||
15 | 3.01 | RO, frt filter | 12 | 5 | Each |
16 | 3.02 | Sediment filter | 13 | 5 | Each |
17 | 3.03 | Carbon filter | 14 | 5 | Each |
18 | 4 | Transinstallation of Split type / Inverter Split type / Cassette type AC units including manpower, transport, testing and commissioning etc., complete as required. | |||
19 | 4.01 | Upto 2 TR | 15 | 5 | Job |
20 | 4.02 | Upto 3TR/4TR | 16 | 5 | Job |
21 | 5 | Refilling suitable refrigerant gas including leak testing with nitrogen gas, testing and commissioning during transinstallation of AC units etc., complete as required. | 17 | 15 | Kg |
22 | 6 | Supply and installation of additional refrigerant copper suction and discharge pipes of suitable size along with foam heat insulated tube wrapped with tape etc complete as required. | |||
23 | 6.01 | Upto 2 TR | 18 | 25 | Mtr |
24 | 6.02 | Upto 3TR/4TR | 19 | 25 | Mtr |
25 | 7 | Providing and fixing of suitable size foam heat insulated tube wrapped with tape for protection for both Copper suction and discharge pipe for the following rating Air conditioner etc., as required. | |||
26 | 7.01 | Upto 2 TR | 20 | 25 | Mtr |
27 | 7.02 | Upto 3TR/4TR | 21 | 25 | Mtr |
28 | 8 | Providing and fixing of 25 mm CPVC drain pipe for Split type / Inverter Split type / Cassette type AC units with necessary saddles complete etc. as requried. | 22 | 100 | Mtr |