Bharat Sanchar Nigam Limited-BSNL has published E-Tender For Ofc Construction Work Under Nofn Project In Newly Created Dhundhwalo Ki Dhani Gp In Nagaur Ssa Of Bikaner Ba. Submission Date for this Tender is 28-01-2021. Optical Fibre Cable Tenders in Bikaner Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work: e-Tender for OFC Construction work under NOFN Project in Newly Created Dhundhwalo Ki Dhani GP in NAGAUR SSA of BIKANER BA | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Excavation of Trenches/HDD Excavation trenches up to a depth of 1.65 m and back filling the excavated trenches after laying the HDPE/PLB Pipe with or without protection as per tender specification (OFT) | |||
2 | 1.01 | in Kuchcha Soil (OFTK) | BI01010001010000000000000515BI0100001113 | 1200 | Per M |
3 | 1.02 | in Pucca Soil (OFTP) | BI01010001010000000000000515BI0100001114 | 500 | Per M |
4 | 1.03 | in Rocky Soil (OFTR) | BI01010001010000000000000515BI0100001115 | 400 | Per M |
5 | 1.04 | Excavation and trenching including manual boring and reinstatement as per construction specification of the tender to a depth of 1.65cm in bituminized/concrete/set stone(rate per meter) for Single PLB Pipe (OFB) | BI01010001010000000000000515BI0100001116 | 1 | Per M |
6 | 1.05 | HDD - Laying of PLB HDPE duct by HDD method at a Depth of 1.65cm or more (for Single PLB Pipe) (OFH) | BI01010001010000000000000515BI0100001117 | 1500 | Per M |
7 | 2 | Laying of PLB HDPE Pipe /GI Pipes/ RCC Pipes/ DWC | |||
8 | 2.01 | Laying of single PLB HDPE Pipes /coil, coupled with coupler (LPH ) | BI01010001010000000000000515BI0100001119 | 2100 | Per M |
9 | 2.02 | Laying and fixing of GI Pipes (Medium duty class having inner diameter of 50mm, as per ISI specifications) in trenches with PLB HDPE Pipes/Coils inside (LGIT) | BI01010001010000000000000515BI0100001120 | 1 | Per M |
10 | 2.03 | Laying and fixing of GI Pipes (Medium duty class having inner diameter of 50mm, as per ISI specifications) in trenches on Bridges and Culverts with PLB HDPE Pipes/Coils inside (LGIC) | BI01010001010000000000000515BI0100001121 | 1 | Per M |
11 | 2.04 | Laying of full round RCC(ISI Mark)/DWC Pipe (as per existing TEC GR no.GR/DWC-34/01 sep 2007 with latest amendments) in trenches over PLB HDPE Pipes/coils, on culverts/bridges/nulla and for cases where cable is laid at less depth (wherever required) (LFRC) | BI01010001010000000000000515BI0100001147 | 1 | Per M |
12 | 2.05 | Laying of split RCC (ISI Mark)/DWC pipe(as per existing TEC GR no.GR/DWC-34/01 sep 2007 with latest amendments) in trenches over PLB HDPE pipes/coils, on culverts/bridges/nulla and for cases where cable is laid at less depth (wherever required) (LSRC) | BI01010001010000000000000515BI0100001122 | 1 | Per M |
13 | 2.06 | Providing cement concrete 1:2:4 at Wheel guard of bridge/ culvert over the toe or in the trench for protection (PCCT) | BI01010001010000000000000515BI0100001123 | 1 | Per CUM |
14 | 2.07 | Providing cement concrete 1:2:4 over the PLB HDPE Pipe with wire mesh in the trenches for protection, where the depth is less than 120 cms (Cement concrete as per specification) (PCCM) | BI01010001010000000000000515BI0100001124 | 1 | Per CUM |
15 | 3 | OF Cable Laying by Pulling/ Blowing | |||
16 | 3.01 | Laying of OF Cable by pulling / blowing method including opening of Manhole, Sealing of PLB HDPE Pipes (OFPB) | BI01010001010000000000000515BI0100001126 | 3800 | Per M |
17 | 4 | Splicing of OF Cable (24 Fibre) | |||
18 | 4.01 | Splicing of fibers in New joint Chambers for making Straight joints on new routes or at FPOI and end to end testing of all fibers after Splicing including installation cost for 24 F OF Cable (SSBJ) | BI01010001010000000000000515BI0100001128 | 2 | Per Joint |
19 | 4.03 | Splicing of all the fibers of 24 F OF Cable in the fiber Termination Box /WSC at the Gram Panchayats and testing all the fibers for continuity. This will also include installation /mounting of the FTB as specified (SFTB) | BI01010001010000000000000515BI0100001130 | 2 | Per FTB |
20 | 5 | Jointing Chamber | |||
21 | 5.01 | Construction of Bricks joint chamber as per specification and the construction practice as specified in the tender document (JCBR) | BI01010001010000000000000515BI0100001132 | 2 | Per Chamber |
22 | 6 | Route Indicator | |||
23 | 6.01 | Supply and fixing of RCC/Stone route/joint indicator by contractor with painting and sign writing as per tender specification (All required materials shall be arranged by the contractor) (RISR) | BI01010001010000000000000515BI0100001134 | 15 | Per Indicator |
24 | 7 | Restoration of Road Surface | |||
25 | 7.01 | Road restoration work with bituminous macadam for semi grouting 50 mm thick and premix carpet surfacing 25mm thick over the grouted surface (total up to 75mm thick), including supply of asphalt etc. to evenly match the road, including consolidation and rolling as per standard specification of DSR 1997. (RRSB) | BI01010001010000000000000515BI0100001136 | 1 | Per M |
26 | 7.02 | Road restoration work with cement concrete 1:4:8 mix for thickness varying from 150mm to 225 mm, including supply of concrete to evenly match the road (RRSC) | BI01010001010000000000000515BI0100001137 | 1 | Peer CuM |
27 | 8 | Route Index Diagram | |||
28 | 8.01 | Supply of route index diagram (6 sets) in hard as well as soft copy on CD for complete OLT. (DRID) | BI01010001010000000000000515BI0100001139 | 3.6 | Per KM |
29 | 8.02 | Videography of the route on which cable is laid (VLCR) | BI01010001010000000000000515BI0100001140 | 3.6 | Per KM |
30 | 9 | Laying of OF Cable in Building (Leading in Work) | |||
31 | 9.01 | Installation of PVC flexible conduit in corridor/risers/exchange premesis and Laying of OF Cable through it (leading in work) (LOIB) | BI01010001010000000000000515BI0100001142 | 1 | Per M |
32 | 10 | Mounting of FDMS at OLT Location | |||
33 | 10.01 | Physical mounting of FDMS on wall at OLT Locations (MFDO) | BI01010001010000000000000515BI0100001144 | 1 | Per FDMS |
34 | 11 | Recovery of Store | |||
35 | 11.01 | Recovery of 24 F Cable Drum | BI01010001010000000000000515BI0100001146 | 2 | Per Drum |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy