Special Repair To Bldg No P-289 And P-322 ( Jcos/Or Md Accn ) In Engr And Sig Zone At Kalimpong Mil Stn Under Ge 867 Ews, KALIMPONG-West Bengal

Military Engineer Services-MES has published Special Repair To Bldg No P-289 And P-322 ( Jcos/Or Md Accn ) In Engr And Sig Zone At Kalimpong Mil Stn Under Ge 867 Ews. Submission Date for this Tender is 03-02-2021. Building Repair Tenders in KALIMPONG West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

26594337
Corrigendum : Special Repair To Bldg No P-289 And P-322 ( Jcos/Or Md Accn ) In Engr And Sig Zone At Kalimpong Mil Stn Under Ge 867 Ews
Open Tender
Indian
West Bengal
KALIMPONG
03-02-2021

Tender Details

Special Repair To Bldg No P-289 And P-322 ( Jcos / Or Md Accn ) In Engr And Sig Zone At Kalimpong Mil Stn Under Ge 867 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Jan-2021 COORIGENDUM Other 03-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SPL REPAIR TO BLDG NO P-289 AND P-322 (JCOS/OR MD ACCN) IN ENGR AND SIG ZONE AT KALIMPONG MIL STN UNDER GE 867 EWS.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for roughening the surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc including for brushing neat cement slurry @ 3 Kg per square meter complete all as specified and directed. BI01010001010000000000000515BI0100001113 547.2 SQM
2 2 M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to IS-13712, grade B-II(a) (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. BI01010001010000000000000515BI0100001114 234 SQM
3 3 M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to IS-13712, grade B-II(a) (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm on vertical surfaces such as dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 10 mm thick backing coat in cement mortar 1:4 complete all as specified and directed. BI01010001010000000000000515BI0100001115 40 SQM
4 4 Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing rubbish off the complete all as specified and directed. BI01010001010000000000000515BI0100001116 420 SQM
5 5 M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to relevant IS (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. 80 SQM
6 6 M&L 300 x 200 x 7 mm thick coloured glazed ceramic tiles fixed as in vertical surface such as risers of steps, skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed. \n 340 SQM
7 7 M&L for machine cut Kota stone slab flooring, 17-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing and exposed edges of Kota stone shall be rounded complete over and including 20 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed. 78 SQM
8 8 M&L for machine cut Kota stone slab as in vertical surfaces such as dado/skirting, 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing and exposed edges of Kota stone shall be rounded complete over and including 10 mm thick backing coat in cement mortar 1:4 as in riser of steps complete all as specified and directed. 30 SQM
9 9 M&L 17-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete over and including 20 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed. 3 SQM
10 10 Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed. 7.1 CUM
11 11 M&L for 50 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges complete all as specified and directed. 78 SQM
12 12 M&L for 40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in floors, path laid in panels and finishing top surfaces of cement concrete even and smooth without using extra cement including fixing only glass dividing strips to divide the area in panels and inserted in position to conform to design complete all as specified and directed. 40 SQM
13 13 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provided for complete all as specified and directed. 9 CUM
14 14 M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed. 9 CUM
15 15 M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed. 110 RM
16 16 Add or deduct for each 25 mm girth or part thereof over or under 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed. 46 RM
17 17 Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition complete all as specified and directed. 8.8 CUM
18 18 M&L for reinforced cement concrete 1:1½:3 (nominal mix) type A1 (using 20mm graded crushed stone aggregate) as in Chajjas and the like complete all as specified and directed. 4.4 CUM
19 19 Use & Waste of formwork to Chajjas, chullah hoods, troughs and similar items including edges rough finished surfaces complete all as specified and directed. 90 SQM
20 20 S&F of TMT bars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. 200 KG
21 21 S&F of TMT bars 6 mm to 8 mm dia, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. 80 KG
22 22 Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. 902.6 SQM
23 23 M&L for 15 mm thick rendering in cement mortar 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and smooth (without using extra cement) complete complete all as specified and directed. 512.3 SQM
24 24 M&L 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement or in the manner specified by the manufacturer and in the proportions indicated all as specified and as directed. Note:-WPC will be measured and paid separately as supply only. 261.7 SQM
25 25 Supply only integral water proofing compond all as specified and as directed. 145.7 KG
26 26 M&L for 10 mm thick rendering in cement mortar 1:3 on concrete surfaces as on ceiling and finished fair and even complete all as specified and directed. 128.5 SQM
27 27 M&L for two coats of oil bound distemper over a coat of priming coat on newly prepared wall surfaces, including thin layer of wall care putty all as specified and directed. 401.7 SQM
28 28 M&L scrapping of existing treatment and applying two coats of thin layer of wall care putty and then applying two coats of oil bound distemper over a coat of priming coat after preparation of wall surfaces complete all as specified and directed. 1537 SQM
29 29 M&L preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash on walls complete all as specified and directed. 110.6 SQM
30 30 M&L for preparation of old plastered or unplastered surfaces of wall and applying one coat of white wash as in wall complete all as specified and directed. 331.8 SQM
31 31 M&L for preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash as in ceiling complete all as specified and directed. 128.6 SQM
32 32 M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash as in ceiling complete all as specified and directed. 385.9 SQM
33 33 M&L for preparation on newly plastered / previously untreated surfaces of wall and applying two coats of exterior emulsion paint (Apex) over one coat of priming coat of alkali-resistant priming paint complete all as specified and directed. 261.7 SQM
34 34 M&L scrapping of existing treatment and applying two coats of exterior emulsion paint(Apex) over one coat of priming coat of alkali-resistant priming paint after preparation of wall surfaces complete all as specified and directed. 785.2 SQM
35 35 Demolition of brickwork or stone / boulder masonary built in cement motar or cement lime mortar all as specified and directed. 3 CUM
36 36 M&L for brick work with sub class 'B' bricks , using old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. 8 CUM
37 37 Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed. 61 EACH
38 38 Taking down chowkhats or frame exc 1.50 and not exc 4 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed. 12 EACH
39 39 Taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed. 18 EACH
40 40 S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered , put together with glue, pinned at joints complete all as specified and directed. 0.2 CUM
41 41 S&F pressed steel frame of size 125 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges,lock , strike plate, etc complete all as specified. 14.7 RM
42 42 S&F pressed steel frame of size 105 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges,lock , strike plate, etc complete all as specified. 58.8 RM
43 43 S&F 30 mm thick (batten thickness) second class hard wood , plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) 21.6 SQM
44 44 S&F 30 mm thick (batten thickness) second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) 10.2 SQM
45 45 S&F of solid PVC door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing given in clause 8.B.3 of SSR -2010 (Part-II Rates) complete all as specified and directed. 66 RM
46 46 S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing given in clause 8.B.2 of SSR -2010 (Part-II Rates) complete all as specified and directed. 36 SQM
47 47 S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified. 39.9 SQM
48 48 S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified. 33.3 SQM
49 49 S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and directed. 9.7 SQM
50 50 S&F steel ventilator fixed type with glazing bar including hinges, steel peg stay, complete complete all as specified and directed. 2.4 SQM
51 51 M&L for 19 mm thick block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work including exposed surfaces finished with external teak wood lipping, 6 mm thick fixed with nails complete all as specified and directed. 26.4 SQM
52 52 M&L for 19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including exposed surfaces finished with external teak wood lipping, 6 mm thick fixed with nails complete all as specified and directed. 22.7 SQM
53 53 S&F of small fittings such as brackets of any type latch and hinge block, shaped door window stops and the like in second class hard wood article not exc 200 cucm each complete all as specified and directed. 12 EACH
54 54 M&L for plain cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts , coping, filling in pressed steel chowkat or similar work including necessary form work as required complete all as specified and directed. 4.9 CUM
55 55 S&F mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings and similar work confirming to Fe-410-0 or Fe 310-0 complete all as specified and directed. 227.7 KG
56 56 S&F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B-21 in repaired complete all as specified and directed. 42 EACH
57 57 S&F of continuous (piano) hinges mild steel bright finish or electro galvanised 30 mm width of flaps complete all as specified and directed. 24 RM
58 58 S&F of 150 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed all as specified and directed. 30 EACH
59 59 S&F of 200 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed all as specified and directed. 30 EACH
60 60 S&F 125 mm size Aluminium handles, cast type, anodised and fixed all as specified and directed. 30 EACH
61 61 S&F 150 mm size Aluminium handles, cast type, anodised and fixed all as specified and directed. 18 EACH
62 62 S&F of 300 mm long aluminium alloy, anodised sliding door bolts with haps staple (bolt type), and fixing clips of sheet, cast or extruted sections and fixing bolt and sliding bolts of extruted sections or cast aluminium alloy and fixed complete all as specified and directed. 12 EACH
63 63 S&F of 100 mm size haps and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screw complete all as specified and directed. 12 EACH
64 64 S&F galvanised mild steel wire cloth 0.40 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed. 66.7 SQM
65 65 S&F in repairs harrison rails mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed. 160 RM
66 66 S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane complete all as specified and directed. 52 SQM
67 67 S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane complete all as specified and directed. 9.7 SQM
68 68 M&L preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 63.6 SQM
69 69 M&L preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. 190.8 SQM
70 70 M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. 85.4 SQM
71 71 M&L preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. 219.7 SQM
72 72 S&F of PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type all as specified and directed. 12 EACH
73 73 S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of "ORRISA" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including trap set in and including necessary lean cement concrete complete all as specified and directed. 12 EACH
74 74 S&F in repairs vitreous china corner wash basin, white colour, size 405x405x205mm, including cutting for and pinning in ends of brackets and waste pipe complete all as specified and directed. Make : Jaquar (CNS-WHT-841) or equvalent approved make 12 EACH
75 75 S&F 15 mm bore pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. 12 EACH
76 76 S&F in repairs bevelled edge mirror of selected quality glass, of any size mounting on 6 mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers, with and including aluminium edging around of mirror complete all as specified and directed 12 SQM
77 77 S&F in repair Brass chromium plated shower rose with or without swivel joints 125 mm size , including fixing to steel pipe or unioncomplete all as specified and directed. 12 EACH
78 78 S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers complete all as specified and directed. 36 EACH
79 79 S&F in repairs angle , stop valve 15 mm bore, (Concealed type) chromium plated, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions long shank and fixed complete all as specified and directed. 24 EACH
80 80 S&F in repairs angle , stop valve 15 mm bore, chromium plated, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 48 EACH
81 81 Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site complete all as specified and directed. 120 RM
82 82 S&F of 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor complete all as specified and directed, 120 RM
83 83 M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth on stone walls complete all as specified and directed. 170 RM
84 84 S&F in repair 15 mm bore chromium plated bib tap fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. 48 EACH
85 85 S&F in repairs grating doom 100mm dia of PTMT (minimum weight 25gms) complete all as specified and directed. 12 EACH
86 86 S&F in repairs kitchen plate rack made out of stainless steel 0.50 mm thick sheet with partitions and size of rack 800 x 250 900 mm with shape and pattern as per sample kept in Sample room of GE Office complete all as specified and directed. 12 EACH
87 87 S&F in repairs brass chromium plated tubular towel rail of 20mm dia 'D' type 60cm long between flanges complete all as specified and directed. 12 EACH
88 88 S&F in repairs 75 mm size PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. 4 EACH
89 89 S & F Salt-glazed stoneware gully trap size 150 x 150 mm square or round mounted type ‘S’, setting and jointed with solvent cement complete all as specified and directed. 4 EACH
90 90 S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. 12 EACH
91 91 S&F in repairs Soap dish, CP, fixed to plugs with chromium plated brass screws complete all as specified and directed 12 EACH
92 92 Demolition and breaking up old broken , PVC (SWR) , Cast Iron, AC, SWG soil waste and vent pipe of 75 mm bore including accessories set in cement mortar and removing rubbish from site complete all as specified and directed. 118 RM
93 93 S&F of 110 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. 78 RM
94 94 S&F of 75 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. 40 RM
95 95 S&F of 110 mm bore PVC (SWR) bend any radius complete all as specified and directed. 8 EACH
96 96 S&F of 110 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed. 8 EACH
97 97 S&F of 75 mm bore PVC (SWR) bend any radius complete all as specified and directed. 8 EACH
98 98 S&F of 75 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed. 12 EACH
99 99 S&F of 110 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement complete all as specified and directed. 8 EACH
100 100 S&F of 75 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement complete all as specified and directed. 8 EACH
101 101 S&F of 110 X 75 mm bore PVC (SWR) reducer including jointing with solvent cement complete all as specified and directed. 8 EACH
102 102 S&F of 75 mm bore PVC (SWR) vent cowl including jointing with solvent cement complete all as specified and directed. 8 EACH
103 103 S&F 110mm bore PVC (SWR) vent Cowl including jointing with solvent cement complete all as specified and directed. 4 EACH
104 104 M&L for 75mm dia outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. 24 EACH
105 105 Taking down copper/aluminium point wiring (light fan, Socket or power ) Complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, light fitting etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors, etc complete all as specified and directed. 139 PER POINT
106 106 Disconnection and taking down distribution boards, switch fuse unit, enclosure for MCB including MCB's of any type and size and keeping aside and refixing the same including all necessary connection complete all as specified and as directed 12 EACH
107 107 Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping not less than 20mm size, medium grade with all necessary fittings, surface wiring , for light / E/fan/Bell point controlled by one switch including 1.5 Sq mm PVC insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes (concealed type in permanent bldg and surface in temporary bldg or as directed ) for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover ,for housing switches, socket outlet, regulator etc. complete all as specified and directed including testing on completion. 63 PER POINT
108 108 All as per item No 107.00 here – in – before but for one 3 / 5 -pin switch socket outlet 5 amps on independent board all as specified and as directed. 36 PER POINT
109 109 All as per item No 107.00 here-in-before but One 3 pin socket outlet 5 Amps on the same board with other switchs with cables 1.5 Sqmm size all as specified and as directed. 16 PER POINT
110 110 All as per item No 107.00 here – in – before but for one switch socket outlet 15 Amps on independent board with 2.5 Sqmm multi stranded and 2.5 Sq mm stranded (for earth) PVC insulated un-sheathed copper conductor FRLS cable 1100 volts grade (conforming to IS) all as specified and as directed. 24 PER POINT
111 111 Supply and fix switch piano flush button, single pole, 5 amps, one way all as specified and as directed. 55 EACH
112 112 Supply & Fixing Bell , AC 230 Volts single pole including mounting block all as specified and as directed. 8 EACH
113 113 Supply & fixing Bell push flush type, 5 Amps button all as specified and as directed. 8 EACH
114 114 Supply & Fixing ceiling rose surface bakelite 65 X 50 mm three terminal all as specified and as directed. 25 EACH
115 115 Supply and fix switch socket combination two – in – one, 3 Pin / 5 Pin, 5 amps flush type all as specified and as directed. 52 EACH
116 116 Supply and fixing switch socket combination five – in – one 6 Pin , 5 / 15 amps flush type universal all as specified and as directed. 24 EACH
117 117 S & F Energy efficient LED tube light fitting 4", 1x22 watt, with bipin holders, connector block, CCT - 6500K, system output lumen not less than 2000lm, extruded aluminium housing with high quality Polycabonate diffuser, wide voltage protection range 140V-270V including connecting up with PVC insulated 3 core sheathed 0.5 sqmm copper conductor two numbers PVC mounting blocks for fixing of fitting complete all as specified and as directed by Engineer-in-charge. Make : Philips, Model - TMC 501, TMC 501P 1XT-LED 22W P3241 or equivalent make as in tenter documents . 25 EACH
118 118 Supply and fixing lamp holder insulated body, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and as directed. 30 EACH
119 119 S & F in LED retro fit lamp B-22 holder base with poly carbonate body and aluminium heat shrink of 5 W complete with tube light all as specified and as directed. 30 EACH
120 120 Taking down KWH and keep in safe custody and refixing the same on hard wood board of suitable size including necessary electric connection from main to KWH meter and KWH meter to out going distribution board complete all as specified and as directed. 10 EACH
121 121 Taking down carefully light fittings of any make and type and refixing the same including all necessary connection complete all as specified and as directed. 15 EACH
122 122 Taking down water storage heater (Geyser) and keep in safe custody and refixing the same including necessary electric/water connection grouting of MS fastener of suitable size complete all as specified and as directed. 12 EACH
123 123 Note 1:- (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates.\nNote 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Note 3:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. BI01010001010000000000000515BI0100001128
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail