Provision Of Latrine Bathroom In Jaslal Pradhan Complex 1 X Wc Urinal And Bathroom At Roorkee Construction Of 300 Mtr Drainage System In Fasf Roorkee Provn Of Drainage For Near Bde Office Bldg No T 7 And Bde Offr Mess Bldg No T 49 Of 135 Inf Bde Camp At, ROORKEE CANTT-Uttarakhand

Military Engineer Services-MES has published Provision Of Latrine Bathroom In Jaslal Pradhan Complex 1 X Wc Urinal And Bathroom At Roorkee Construction Of 300 Mtr Drainage System In Fasf Roorkee Provn Of Drainage For Near Bde Office Bldg No T 7 And Bde Offr Mess Bldg No T 49 Of 135 Inf Bde Camp At. Submission Date for this Tender is 09-02-2021. Drainage Tenders in ROORKEE CANTT Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

26593161
Corrigendum : Provision Of Latrine Bathroom In Jaslal Pradhan Complex 1 X Wc Urinal And Bathroom At Roorkee Construction Of 300 Mtr Drainage System In Fasf Roorkee Provn Of Drainage For Near Bde Office Bldg No T 7 And Bde Offr Mess Bldg No T 49 Of 135 Inf Bde Camp At
National Competitive Bid
Indian
Uttarakhand
ROORKEE CANTT
09-02-2021

Tender Details

Provision Of Latrine Bathroom In Jaslal Pradhan Complex 1 X Wc Urinal And Bathroom At Roorkee Construction Of 300 Mtr Drainage System In Fasf Roorkee Provn Of Drainage For Near Bde Office Bldg No T 7 And Bde Offr Mess Bldg No T 49 Of 135 Inf Bde Camp At

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 84500.0 /-
Tender Value
INR 42.25 Lakhs /-

BOQ Items

Name of Work: PROVN OF LATRINE BATHROOM IN JASLAL PRADHAN COMPLEX (1 X WC+ URINAL AND BATHROOM) AT ROORKEE, CONSTRUCTION OF 300 MTR DRAINAGE SYSTEM IN FASF ROORKEE, PROVN OF DRAINAGE FOR NEAR BDE OFFICE BLDG NO T-7 AND BDE OFFR MESS BLDG NO T-49 OF 135 INF BDE CAMP AT ROORKEE AND PROVN OF RETAINING WALL NEAR T- 50 AND T-31 OF 13 DOGRA (NEW UNIT 6 GRENADIERS ) AT ROORKEE UNDER GE ROORKEE.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for surface dressing not exc 15 cm deep in soft/loose soil complete all as specified and directed. 36 Sqm
2 2 M&L for excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. 997.4 Cum
3 3 M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. 257.21 Cum
4 4 M&L for removing excavated soil n exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. 740.16 Cum
5 5 M&L for PCC 1 : 4 : 8 type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. 13.4 Cum
6 6 M& for PCC 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in coping, DPC, embedding hold fast, etc complete all as specified and directed. 13.56 Cum
7 7 M&L for RCC 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5 m span complete all as specified and directed. 0.69 Cum
8 8 M&L for RCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in chajjas, etc complete all as specified and directed. 0.25 Cum
9 9 M&L for reinforced precast cement concrete cover slabs type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in landing, cover slab for manholes etc chullah hoods, chajjas, water troughs, shelves and similar articles with plain faces and set in cm 1:6 complete all as specified and directed. 15.67 Cum
10 10 M&L for RCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, roof slabs and the like complete all as specified and directed. 4.6215 Cum
11 11 M&L for Glazed ceramic tiles 300x200 x 7 mm thick coloured/shaded as in vertical surfaces such as skirting dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the surface over 10 mm thick cement plaster in CM 1:4 complete all as specified and directed. 54 Sqm
12 12 M&L for coloured jointless Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cm 1:6 complete all as specified and directed. 25 Sqm
13 13 M&L for 75 mm thick cement concrete 1:3:6 type C-2, (using 40mm graded stone aggregate) as in plinth protection, etc. complete all as specified and directed. 16.5 Sqm
14 14 M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cm 1:6 complete all as specified and directed. 190.5 Cum
15 15 M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cm 1:4 complete all as specified and directed. 108.39 Cum
16 16 M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. 15 Sqm
17 17 M&L for rough finished form work to chajjas and similar works complete all as specified and directed. 1 Sqm
18 18 M&L for rough finished flat form work to soffits of suspended slabs such as roof slab, etc not exc 200 mm horizontal thickness complete all as specified and directed. 31 Sqm
19 19 M&L for rough finished form work to edges of concrete flats, RCC/PCC bands, etc exc 10 cm but not exc 20 cm wide complete all as specified and directed. 8 RM
20 20 M&L for rendering 12 mm Thick in CM (1:6) on Brick surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed. 18 Sqm
21 21 M&L for rendering 15mm thick consist of two coats top layer 5 mm thick in CM 1:4 (mixed with WPC) over 10 mm th in CM 1:6, on fair faces of brick work ( WPC shall be measured & paid seperately) finished even & fair all as specified. 50 Sqm
22 22 M&L for Rendering 10mm thick in cm 1:4 on concrete surfaces in ceiling complete all as specified and directed. 31 Sqm
23 23 Supply only WPC complete all as specified and directed. 8 Kg
24 24 M&L preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified & directed. 71 Sqm
25 25 M&L for preparation of new concrete surfaces of ceiling and applying three coats of white wash complete all as specified and directed. 31 Sqm
26 26 M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. 12345 Kg
27 27 M&L Mild steel TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. 30 Kg
28 28 S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. 20 RM
29 29 S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. 5.2 Sqm
30 30 All as per BOQ item No. 28.00 here-in-before but fully glazed i e glass panes used instead of 5mm PVC sheets panels for ventilaters with frame incl all necessary fittings i.e. hinges, tower bolt, handle and stopper etc complete all as specified and directed. 5 Sqm
31 31 S&F MS work as in hold fasts, bands supports, clamps, wall ties hooks incl nut and bolts etc. conforming to Fe-410-0 or Fe-310-0 including welding etc. all as specified. 5 Kg
32 32 S&F PTMT But hinges 100 mm complete all as specified and directed. Make 'PRAYAG' 12 Each
33 33 S&F PTMT Tower bolt 150 mm complete all as specified and directed. Make 'PRAYAG' 8 Each
34 34 S&F PTMT door handles 125mm complete all as specified and directed. Make 'PRAYAG' 8 Each
35 35 S& F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. 1 Each
36 36 S & F vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rests, P or S type trap (excluding flushing cistern and flush pipe), lime concrete bedding ,etc complete all as specified and directed. 2 Each
37 37 S&F PVC flushing cistern low level valve less syphonic action with PVC float and handle including brackets and flush pipe etc complete of capacity 10 Ltr complete all as specified and directed. 2 Each
38 38 S&F 600x450mmx5mm thick bevelled edges mirror of selected quality mounted on 6mm thick AC building board or 6mm thick commercial ply wood and fixed to wooden ply with CP brass screws and cup washer complete all as specified and directed. 1 Each
39 39 M&L for 1000 ltr cap Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. 1 Each
40 40 S&F 15 mm dia GI Tubing Medium Grade with all fittings and fixed complete to walls and ceiling or laid in floor etc, complete all as specified and directed. 35 RM
41 41 S&F 20 mm dia GI Tubing Medium Grade with all fittings and fixed complete to walls and ceiling or laid in floor etc, complete all as specified and directed. 20 RM
42 42 S&F 15 mm bore Bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. 4 Each
43 43 S&F 15 mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe and fixed complete all as specified and directed. 2 Each
44 44 S&F 20 mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 2 Each
45 45 S&F 20 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms) complete all as specified and directed. 2 Each
46 46 M&L for PVC connection of PTMT of size 15mm dia and 450 mm long compete all as specified and directed. 3 Nos
47 47 S&F PVC Pipe (SWR) 75mm laid in floors or trenches, fixed to walls, etc complete all as specified and directed. 15 RM
48 48 S&F floor trap of PVC 75 mm out let dia with grating and jointed to waste pipe complete all as specified and directed. 3 Each
49 49 S&F 75 mm bore PVC (SWR) bend any radius complete all as specified and directed. 2 Each
50 50 S&F PVC Pipe (SWR) 110mm laid in floors or trenches complete all as specified and directed. 18.5 RM
51 51 S&F 110 mm bore PVC (SWR) bend any radius complete all as specified and directed. 6 Each
52 52 S&F 110 mm bore PVC (SWR) junction double, (double T) equal or unequal complete all as specified and directed. 1 Each
53 53 S&F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed. 1 Each
54 54 M&L for concrete bed in 1:3:6, type C-2 to 100 mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. 10 RM
55 55 M&L for 100 mm bore salt glazed stoneware drain pipes laid in trenches and jointed complete all as specified and directed. 10 RM
56 56 M&L rendering 15mm thick in CM 1:4 mixed with WPC on roof surfacs finished even & smooth without using extra cement complete all as specified and directed. \nNote : WPC shall be meausured & paid separately. 30.81 Sqm
57 57 S&F Vitreous China urinals, bowl type half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws and cp water spreader, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern and trap) including waste pipe complete all as specified and as directed. 1 Each
58 58 S & F in repairs CP brass shower rose (single lever over head shower incl shower arm casted 190 mm long flat shape with flange) 125 mm size suitable for 15 mm bore pipe complete all as specified and directed (Model : OHS-1989, SHA-483 Make : Jaguar OR EQUIVALENT RANGE OF MARC, JOHNSON). 1 Each
59 59 S & F in repairs 15mm Stop valves, fancy type, chromium plated with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butterfly or push button type handle as required, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 3 Each
60 60 S&F in repair vitreous basin wash besine white flat back size 550 x 450mm inclduing fancy CP pillar tap 15mm, waste fitting and waste pipe, chain and plug porcelain stopper inclduing brackets and necessary connection complete all as spd. 2 Each
61 61 M & L for septic tanks, including excavation,earth work, foundation concrete in PCC 1:2:4, brick work in CM 1:4, RCC slab covers including RCC precast manhole cover having 6 mm plate embedded all around/fibre reinforcement cover with angle iron frame vent shaft and sludge chambers etc. complete for 10 users complete all as shown on drawing and as specified and directed 1 Each
62 62 Construction of Soakage well including excavation/earth work, foundation concrete in PCC 1:3:6, wells of brick work in CM 1:4 of Honey combed and RCC 1:2:4, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in in PCC 1:2:4 RR masonry / Filling with brick bats, complete of size 1.8 M dia X 3.0 M deep complete all as shown on drawings and as specified and directed 1 Each
63 63 M&L for roof treatment with polymeric membrance (APP based) with non woven polyster mat as reinforcement with following:-\n(a) M&L for surface preparation by removal of loose particle to ensure or clean smooth and dry surrfaceand preparing the surface and providing 15 mm thick in CM 1:3 mixed with WPC.\n(b) M&L for providing & laying a coat of cold applied bitumen 85/25 based primer on entire surface @ 0.30 Ltr/Sqm on dry and clean surface.\n(c) M&L for providing & laying APP based polymeric membrane of 3 mm thickness of weight of 3.0 Kg/Sqm with non wovenpolyster fibre as reinforcement on primed surface by torch application with side over laps & joints over laps etc as per manufacturers instruction.\n(d) M&L for finishing of top surface by two coat of aluminium paint over a coat of blown bitumen 85/25 grade @ 1.2 Kg/Sqm grouted all as specified and as per manufacturers instruction. 30 Sqm
64 64 M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed 169.6 cum
65 65 M&L for rendering 15 mm thick in CM 1:4 on brick or concrete surfaces finished even and fair without using extra cement complete all as specified and directed. 675 sqm
66 66 M&L for rendering 10 mm thick in CM 1:4 on brick or concrete surfaces finished even and fair without using extra cement complete all as specified and directed. 700 sqm
67 67 M&L for providing cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as in surface channel and drain complete all as specified and directed. 30.88 cum
68 68 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. 750 RM
69 69 Add or deduct for each 25 mm girth or part there of over or under 30cm ditto complete all as specified and directed. 5400 Rm
70 70 M&L for concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; in cement concrete 1:3:6 type C-2 (using 40mm greded stone aggregate) for 300mm dia pipe complete all as specified and directed. 15 Rm
71 71 M & L for Chequered cement concrete tiles With grey cement and no pigment 20cm x 20cm x 25mm thick over and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes CM 1:4 complete all as specified and directed. 50 sqm
72 72 M&L for 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base to floor complete all as specified and directed 50 Sqm
73 73 S&F Reinforced concrete pipes class NP2 laid and jointed complete with collars of 600 mm bore of pipe complete all as specified and directed. 10 RM
74 74 S&F Reinforced concrete pipes class NP2 laid and jointed complete with collars of 450 mm bore of pipe complete all as specified and directed. 10 RM
75 75 S&F Reinforced concrete pipes class NP2 laid and jointed complete with collars of 300 mm bore of pipe complete all as specified and directed. 33 RM
76 76 M&L for 110mm PVC(SWR) rain water pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed. 20 Rm
77 77 M& L for hardcore of broken stone/boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 5 Cum
78 78 M&L framed work such as grills,gratinings,etc,with ends of bars shouldered and/or riveted,or forged into spikers; framed guard bars; barrediron doors; ladders;framedbalusters; walk ways; railings; framedwork of watertanks and similar work conforming to Fe 290.Gde-E-165 complete all as specified and directed. 481 Kg
79 79 M & L for RCC M 25 Desigen mix foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 16.3 cum
80 80 M & L for RCC M 25 Desigen mix f Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. 80 cum
81 81 S & F for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter all as specified and directed 32.5 sqm
82 82 S & F for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter all as specified and directed 357 sqm
83 83 M & L for Point wiring in repair with PVC insulated PVC unsheathed electric (FRLS) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of pvc conduit surface casing caping will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes (normal and moduler type) of 1.6 mm thick (duly painted with two coats of black bituminous paint over a coat of red oxide primer in and out sides) with and including plastic laminated bakelite sheet cover of hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc for the following and Make of wire- Grandlay/Havells /polycab
84 84 (a) One light point controlled by one one way switch 7 Each\nPoint
85 85 S&F switch piano flush type polycarbonate single pole one way 5 Amps. 7 Each
86 86 S&F Ceiling rose in poly carbonate 3 terminal brass, 6 Amps, 230 volts AC ISI marked, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm dia complete all as specified. 4 Each
87 87 M&L for MCB single pole, 6 to 32 Amp 240 volt C curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters complete including suitable size copper Lugs complete all as specified and directed. MAKE-LEGRAND / SCHNEIDER /SEIMENS 2 Each
88 88 M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interier dimensions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3of SSR 2009 including testing after completion. 1 Each
89 89 M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable all as specified and directed by Engr - in - Charge. (Note:- Punning thickness shall be measured) 3 CUM
90 90 Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed. 0.48 1000 \nNos
91 91 S&F Lamp Holder, PVC/Polycarbonate type insulated body with, back plate including LED bulb of 12 watts, B-22 base complete complete all as specified and directed. Make: Anchor(Penta)/Havells 3 Each
92 92 S&F SPN DB 4 way double door flush to wall metal type with 200 Amp bus bar 240 volt Make: Legrand, IP 43 Cat Pt No 507620 or equivalent in ABB/C&S 1 Each
93 93 S&F MCB SPN 32 Amps AC 230 Volts, 'C' curve series with 10 KA breaking cpacity complete all as specified and directed. MAKE-LEGRAND / SCHNEIDER /SEIMENS 1 Each
94 94 S&F of LED tube light fitting 1x18/20 Watt LED batten type with bipin holders complete with all accessories and including LED polycarbonate tube light rod T8, 4 feet long 18/20 watt double ended and making connections with the help of three core PVC insulated unsheathed copper conductor mulstistanded wire of suitable length complete all as spcified and directed . Make : C&S Cat Pt No LTDC01220WLED/WD (LTDC161820WLED + LT4F20WLEDT8/WD) or equivalant in Havells / Bajaj 2 Each
95 95 Supply and fix LED building secuirty light fitting with LED 25 Watts, suitable for saingle phase, 230 V, 50 Hz, AC supply complete with GI pipe 40 mm long bend tp shape fixed on wall with MS flat clamp -02 Nos and nut bolts, including taking down old light fitting of any type and testing complete all as specified and directed . Make - C&S Cat No LTESS25WLED/LS or equivalant model in Bajaj, Havells, Crompton 1 Each
96 96 S&F Exhaust fan 300 mm Sweep with louvers, 240volt, single phase including making connection cutting holes of suitable dia for exhaust fan in any type of wall including finishing and making good as per existing surrounded wall complete all as directed by Engineer - in -Charge. Make : Havells turbo Force SP 300 mm or equivalent in Bajaj / Havells 1 Each
97 97 Supply, laying LT cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power couble (heavy duty) with aluminium conductor, 1100 volts grade of size 10 Sqmm 2 core fixed to wall/floor/ceiling with clamps/PVC shaddles at 1 mtr apart complete and making connections 80 RM
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail