Local Self Government Department has published Shornur Municipality Annual Project-2020-21 . Veterinary Hospital Maintenance Pro . No 237/20-21 Building Maintenance. Submission Date for this Tender is 20-01-2021. Building Repair Tenders in SHORNUR MUNICIPALITY Kerala. Bidders can get complete Tender details and download the document.
Work Name:Shornur Municipality Annual Project-2020-21. Veterinary Hospital Maintenance PRO.NO : 237/20-21 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | APPX--1....Maintenance Of veterinary hospital | BI01010001010000000000000515BI0100001113 | ||
2 | 1.001 | 15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | BI01010001010000000000000515BI0100001114 | 3.75 | cum |
3 | 1.002 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | BI01010001010000000000000515BI0100001115 | 14.82 | cum |
4 | 1.003 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001116 | 7.615 | cum |
5 | 1.004 | 60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site | BI01010001010000000000000515BI0100001117 | 8.417 | cum |
6 | 1.005 | 7.2.1 : Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand) | BI01010001010000000000000515BI0100001118 | 4.496 | cum |
7 | 1.006 | 2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | BI01010001010000000000000515BI0100001119 | 11.685 | cum |
8 | 1.007 | 4.3.1 : Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns | BI01010001010000000000000515BI0100001120 | 35.77 | sqm |
9 | 1.008 | 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001121 | 554.25 | kg |
10 | 1.009 | 5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001122 | 4.746 | cum |
11 | 1.01 | 50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | BI01010001010000000000000515BI0100001123 | 1.8 | cum |
12 | 1.011 | 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | BI01010001010000000000000515BI0100001124 | 85 | kg |
13 | 1.012 | 10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | BI01010001010000000000000515BI0100001125 | 910 | kilogram |
14 | 1.013 | od755841/2020_2021 : Providing and fixing precoated galvanaised iron profile sheets(size,shape and pitch of corrugation as approoved by Engineers in charge)0.30 mm(+0.05%) total coated thickness with zi8nc coating 120grams per sqm as per IS 277,in 240 mpa steel grade 5-7 microns epoxy primer on both side of the sheet and polyster top coat 15-18 microns.sheet should have protective guard film of 25 micron minimum to avoid scratches during transportation and should be supplied in single length up to 12mt or as desired by Engineer in charge.The sheet shall be fixed using self drilling/self tapping screws of size (5.5*55mm) with EPDM seal,complete up too any pitch in horizontal vertical or curved surfaces,excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001126 | 156 | sqm |
15 | 1.014 | od946575/2020_2021 : Supplying and fixing 150mm dia pvc rain water gutter semi circular section including fitting with<br>32mmx5mm Ms flat supporters at 1m interval etc complete | BI01010001010000000000000515BI0100001127 | 34 | metre |
16 | 1.015 | 10.5.2 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece | BI01010001010000000000000515BI0100001128 | 3 | sqm |
17 | 1.016 | 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | BI01010001010000000000000515BI0100001129 | 36.475 | sqm |
18 | 1.017 | 13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) | BI01010001010000000000000515BI0100001130 | 27.8 | sqm |
19 | 1.018 | 13.18 : Neat cement punning | BI01010001010000000000000515BI0100001131 | 85.3 | sqm |
20 | 1.019 | 11.19.1 : Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand):Light shade pigment using white cement | BI01010001010000000000000515BI0100001132 | 57.5 | sqm |
21 | 1.02 | 14.43 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | BI01010001010000000000000515BI0100001133 | 305.825 | sqm |
22 | 1.021 | 13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | BI01010001010000000000000515BI0100001134 | 305.825 | sqm |
23 | 1.022 | 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work | BI01010001010000000000000515BI0100001135 | 97.68 | sqm |
24 | 1.023 | 4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001136 | 0.125 | cum |
25 | 1.024 | 50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall | BI01010001010000000000000515BI0100001137 | 10 | metre |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy