Military Engineer Services-MES has published Certain Repair To Br And Em Works Amg 2020-21 For 1 Archer At Mil Stn Dharchula. Submission Date for this Tender is 09-02-2021. Electromechanical Work Tenders in Dharchula Uttarakhand. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Feb-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-02-2021 |
Name of Work: CERTAIN REPAIR TO BR AND EM WORKS AMG 2020-21 FOR 1 ARCHER AT MIL STN DHARCHULA | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 0.05 | DESCRIPTION OF ITEMS | |||
2 | 1 | Taking down chowkhats or frame n. exc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed. | 7 | Each | |
3 | 2 | Taking down chowkhats or frame exc 1.5 sqm but nexc 4.00 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed. | 2 | Each | |
4 | 3 | Taking down Shutters of any description exc 1 sq. m but nexc 2 sqm each complete all as specified and directed. | 6 | Each | |
5 | 4 | M & L for plain solid chowkhats and frame wrought framed rebated on solid rounded or chamfered of 2nd class hardwood complete all as specified and directed. | 0.04 | Cum | |
6 | 5 | M & L for 35mm thick pannelled door shutters of 2nd class hard wood any number of panels with panels of timber flat on both sides or medium density venered particle board 12mm thick in panel inserts complete all as specified and directed. | 8 | Sqm | |
7 | 6 | M & L for 30mm thick glazed skelton shutters of 2nd class hard wood with or without sash bars edges of framing plain chamfered or rounded with cut and metered beads to secure glass of section as per SSR-I complete all as specified and directed. | 9 | Sqm | |
8 | 7 | M & L for solid PVC Door Frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per complete all as specified and directed. | 24 | RM | |
9 | 8 | S & F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed. | 8 | Sqm | |
10 | 9 | S & F powder coated aluminium frame for doors, widnows, ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified and directed | 20 | Kg | |
11 | 10 | S & F powder coated aluminium window and ventilator shutters, fixed type without sash bar aluminium section weighing 0.55 Kg/m including necessary jointing cleats glazing clips, rubber packing, anodised aluminium snap beading screws etc complete all as specified and directed. | 2.5 | Sqm | |
12 | 11 | S & F sheet glass ordinary quality 5.5mm thick in squares exc. 0.5 sqm in each pane | 2.4 | Sqm | |
13 | 12 | S & F 3mm thick sheet glass ordinary quality and glazing with oil putty in square nexc. 0.5 sqm in each pane complete all as specified and directed. | 7 | Sqm | |
14 | 13 | S & F galvanised steel mild steel wire cloth, 0.63mm nominal dia or wire and average width of aparture 1.40mm and fixed with tinned tack or galvanised wire staplses to steel frame complete all as specified and directed. | 10 | Sqm | |
15 | 14 | S & F 100mm mild steel but hinges medium weight, cold rolled complete all as specified and directed. | 40 | Each | |
16 | 15 | S & F 150mm aluminium handles, cast type anodised complete all as specified and directed. | 26 | Each | |
17 | 16 | S & F 200 mm aluminium anodised barrel tower bolts extruded section complete all as specified and directed. | 26 | Each | |
18 | 17 | S & F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple bolt type) and fixing bolts of extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. | 4 | Each | |
19 | 18 | S & F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete specified and directed. | 4 | Each | |
20 | 19 | Roughening surfaces of old concrete floor by picking ,sweeping clean and washing down with water to remove dust etc. complete all as specified and directed. | 360 | Sqm | |
21 | 20 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing unserviceable tiles and rubbish off the premises complete all as specified and directed. | 144 | Sqm | |
22 | 22 | M & L for Joint free non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm and not exceeding 0.18 sqm, in floors over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as spfd & directed. | 380 | Sqm | |
23 | 23 | M & L for machine cut kota stone slab flooring 20-25mm thick over 15mm thick cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing polished complete all as specified and directed. | 50 | Sqm | |
24 | 24 | S & F glazed ceramic tiles in vertical surface 300x200x7mm thick set and jointed in neat cement slurry including 10 mm thick cement plaster on wall as in backing coat in CM (1:4) and pointed in coloured cement to match the shades of tiles complete all as spfd & directed. | 52 | Sqm | |
25 | 25 | Demolition of cement concrete in ground floor,paving nexc 15mm thick(below or above GL) including removing and rubbish off the premises complete all as specified and directed | 6 | Cum | |
26 | 26 | M & L for 100 mm thick Plain Cement concrete type D2 1:4:8 using 40mm graded stone aggregate as in sub base and paving complete all as specified and directed. | 45 | Sqm | |
27 | 27 | M & L for 75mm thick PCC 1:3:6, type C-2, as in pavings/hard standing/path/Plinth protection etc finished even & smooth without using extra cement including forming necessary joints 12 mm wide to the full depth of PCC at every 3 metre and at change in direction complete all as specified & directed. | 70 | Sqm | |
28 | 28 | M & L for Hardcore of broken stone boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified & directed. | 1.5 | Cum | |
29 | 29 | Taking down cement plaster on brick, cocrete or stone walls, of any description including raking out joints, hacking for key, scrubbing down with water, etc complete all as spfd and directed.\n | 100 | Sqm | |
30 | 30 | M & L 15 mm thick rendering in CM 1:4 on brick/concrete surfaces including finishing the surfaces fair and even complete all as specified and directed. | 190 | Sqm | |
31 | 31 | M & L 15mm thick rendering in CM 1:6 on brick/concrete surfaces including finishing the surfaces fair and even complete all as specified and directed. | 30 | Sqm | |
32 | 32 | Dismantling of wall and celing boards/AC sheets and insulation boards/slabs/blankets, in any thickness & any position including cover fillets complete all as specified and directed. | 185 | Sqm | |
33 | 33 | Dismantling of timber scantling 40 sqcm and over in section in any position for unframed works complete all as specified and directed. | 1.2 | Cum | |
34 | 34 | Dismantling of timber scantling 40 Sqcm under in section in any position, fixed with nails unframed work complete all as spfd & directed. | 200 | RM | |
35 | 35 | S & F 12m thick perforated tiles for insulation purpose 60x60cm in size ,fixed with staples or snap grid in ceiling complete all as specified and directed. | 185 | Sqm | |
36 | 36 | S & F anodised aluminium snap grid of size 606 x605mm frame work for false ceiling complete all as specified and directed. | 185 | Sqm | |
37 | 37 | S & F hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long complete all as specified and directed. | 185 | Sqm | |
38 | 38 | Dismantling of plain or corrugated steel sheeting of any guage/thickness in roof covering/wall clading complete all as spfd and directed. | 140 | Sqm | |
39 | 39 | S & F 0.63mm thick galvanised corrugated mild steel sheeting with two corrugation side lap fixed with 'L' type or 'J' type or cranked hook bolts class 8 complete all as spfd & directed. | 80 | Sqm | |
40 | 40 | S & F 0.63 mm thick galvanised plain mild steel sheeting in ridges, hips, valley, gutter fixed with 'L' type or 'J' type or cranked hook bolts class 8 complete all as spfd & directed. | 20 | Sqm | |
41 | 41 | S & F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrutation with coatch screw washer in roof, wall etc complete all as specified and directed. | 29 | Sqm | |
42 | 42 | S & F Pre-painted galvalume aluminium zinc coating GI based corrougted steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof coverigs/cladding to wall, fixed with self tapping screws all as specified and directed. | 8 | Sqm | |
43 | 43 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof coverigs/cladding(in ridge and gutter) to wall, fixed with self tapping screws all as specified and directed. | 3 | Sqm | |
44 | 44 | S & F solid PVC wall lining consisting of 5mm thick single side prelaminated PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed. | 30 | Sqm | |
45 | 45 | S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as specified and directed. | 110 | RM | |
46 | 46 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. | 2 | Per Qtl | |
47 | 47 | S & F roof truss (framed), trussed, purlins, cranes gantries, rails and fastening (Beam, tee, angle, channel or flat sections) including distance pieces etc. complete all as specified and directed. | 200 | KG | |
48 | 48 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n. exc 10 sqm on plan and n exc 1.5 m in depth and getting out hard and dense soil complete all as specified and directed. | 20 | Cum | |
49 | 49 | Retruning filling in, including spreading leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. | 7 | Cum | |
50 | 50 | Removing excavated soil exc 250 m but n.exc 500 m and depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed. | 13 | Cum | |
51 | 51 | Demolition of brick work or stone/boulder masonary built in cement mortar complete all speecified and directed | 33 | Cum | |
52 | 52 | M & L for precast cement concrete block masonary with P.C.C 1:3:6 mix type C-1 block etc 10cm in width and set in CM1:6 complete all as specified and directed | 4 | Cum | |
53 | 53 | M & L for walling of random rubble, uncoursed as well bounded, bedded and solidly hearted, built in cment mortar 1:6 complete all as specified and as directed. | 20 | Cum | |
54 | 54 | All as per as item No 53 above but except stone | 5 | Cum | |
55 | 55 | Demolition and breaking up drain pipes (Salt glazed ware,AC or Reinfoced concrete),150mm dia, set in cement mortar, complete all as specified and directed. \nNote :- Excavation & earth work shall be measured seprately. | 28 | RM | |
56 | 56 | S & F reinforced concrete pipes, class NP2, 150mm and jointed complete with collars, complete all as specified and directed. | 28 | RM | |
57 | 57 | M & L for concrete bed 1:4:8 type D-2 (Using 40 mm graded stone aggregate) as in drain pipes including packing under, and haunching against the side of pipes after the are laid and tested in 150 mm bore pipe, complete all as specified and directed. | 28 | RM | |
58 | 58 | M & L for plain cement concrete 1:2:4 type B1 using 20mm graded aggregates in surface channels and drains complete all as specified and directed. | 5 | Cum | |
59 | 59 | M & L for precast cement concrete type B1 1:2:4 (Using 20 mm graded stone aggregate) as in cover slabs, manhole cover, chamber cover and drainge cover set in cement mortar 1:6 including necessary formwok complete all as specified and directed. | 0.7 | Cum | |
60 | 60 | M & L for TMT bars, 6 to 8mm, cut to length, bent to shape required including cranking,bending spirally for hooping for column, hooking ends and binding with and incl MS wire(annealed) not less than 0.9 mm dia complete all as specified and directed. | 85 | Kg | |
61 | 61 | M & L for 19mm thick block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face fixed with screws to timber framework complete all as specified and directed. | 10 | Sqm | |
62 | 62 | M & L for 18mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed. | 10 | Sqm | |
63 | 63 | S & F 6mm thick teak wood lipping fixed with nails to block board or veneered particle board complete all as specified and directed. | 45 | RM | |
64 | 64 | S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised (width of flaps 30mm) complete all as specified and directed. | 1 | RM | |
65 | 65 | M & L for 20mm thick granite (of any type) work (tabld rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and the like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. | 6 | Sqm | |
66 | 66 | S & F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers & waste coupling, including bedding in cement mortar to dwarf wall or including fixing on cantilever brackets & connecting union to pipe over all size 915x460mm bowl size 410x330 mmx160mm complete all as specified and directed. | 1 | Each | |
67 | 67 | Cleaning and removing all scale and dirt etc from tanks and from mouths of of circulating pipes etc capacity of exc. 250 ltrs but n. exc 500 ltr including embossing date of completion of cleaning by stencil with paint complete all as specified and directed. | 5 | Each | |
68 | 68 | All as per item no 67 above but water tank of capacity exc 500 ltr but n. exc 1000 ltrs | 4 | Each | |
69 | 69 | All as per item no 67 above but water tank of capacity 10000 ltrs | 1 | Each | |
70 | 70 | Taking up existing manhole covers and cleaning of soak well / septic tank of any size and any capacity, by dewatering and removing sludge in liquid mud state after emptying the sewage / waste water and removing the sludge to a distance exc. 250 m and n.exc. 500m and disposed off as directed by the Engineer-in-Charge, and placing the cover in position, complete all as specified and directed. \nNote:- Measurement shall be made for size of tank/soak well up to water level) | 75 | Cum | |
71 | 71 | S & F 25mm bore GI tubing with all fittings medium grade fixed to wall or laid in floor etc including taking down old pipe, complete all as specified and directed. | 100 | RM | |
72 | 72 | S & F 15mm bore GI tubing with all fittings medium grade fixed to wall or laid in floor etc including taking down old pipe, complete all as specified and directed. | 40 | RM | |
73 | 73 | S & F in repairs 500 Ltr rotational moulded polyethylene triple layered water stotage tanks \n(cylinderical vetrticle with closed top) hoisted & fixed in position complete all as specified and directed. | 1 | Each | |
74 | 74 | S & F in repairs vitreous china squatting pan "Orissa pattern" size 580mm x 440mm white with integral foot rests, trap including provn of lime concrete bedding complete all as spfd & directed. | 2 | Each | |
75 | 75 | S & F in repairs vitrous china wash down water closetpan (padestal pattern) white colour(excluding cistern), complete all as specified and directed. | 1 | Each | |
76 | 76 | S & F in repairs PVC flushing cistern low level white with inlet pipe, flush pipe, ball valve, float valve and handle including brackets complete all as specified and directed. | 3 | Each | |
77 | 77 | S & F in repairs vitrous china wash basin, white flat back size 550X400mm including brackets fixing in position complete all as specified and directed. | 1 | Each | |
78 | 78 | S & F in repairs 15 mm bore bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as spfd & directed. | 3 | Each | |
79 | 79 | S & F in repairs Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as spfd & directed. | 2 | Each | |
80 | 80 | S & F in repairs 15 mm Stop valves, cast copper alloy, screwed down, high pre-ssure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as spfd & directed. | 3 | Each | |
81 | 81 | S & F PVC in repairs connections 15 mm size with PTMT nuts of length 450mm long all as spfd and as directed. | 4 | Each | |
82 | 82 | S & F in repairs 110mm PVC (SWR) pipe single socketed in any length with rubber ring, joints laid in trenches or in floor complete all as spfd & directed. | 5 | RM | |
83 | 83 | S & F in repairs 125/110 mm PVC Traps 'P' or 'S' all as spfd and directed. | 3 | Each | |
84 | 84 | S & F in repairs tubular towel rail 20mm dia, D type, 60cm long between flange complete all as specified and directed. | 2 | Each | |
85 | 85 | S & F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as spfd & directed. | 1 | Each | |
86 | 86 | M & L for two coat of synthetic enamel paint over a coat of pink primer to new/old wooden surface of any description exc 10 cm girth or width including prepration of new/old wooden surfaces complete all as specified and directed. | 45 | Sqm | |
87 | 87 | M & L for two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces of any description over 10 cm in width or girth incl preparation of new steel surfaces complete all as spfd and directed. | 20 | Sqm | |
88 | 88 | M & L for preparation of plastered or unplastered old decorated surfaces of walls applying one coat of white wash on walls complete all as specified and directed. | 2700 | Sqm | |
89 | 89 | All as per Item No. 88 above but applying one coat of white wash on ceiling complete all as specified and directed. | 130 | Sqm | |
90 | 90 | M & L for preparing old previously treated surfaces of corrugated/plain sheets as in roof covering /wall over 10 cm girth or width by cleaning straightening if any removing rust and making good where required and applying one coat of synthetic enamel paint on old steel surfaces complete all as specified and directed. | 530 | Sqm | |
91 | 91 | M & L for preparation of (previously treated) plastered surfaces of walls and applying one coat of oil emulsion distemper any tint of walls complete all as specified and directed. | 80 | Sqm | |
92 | 92 | M & L for preparation of plastered or unplastered old decorated surfaces of walls and applying one coat of cement base paint on walls complete all as specified and directed. | 160 | Sqm | |
93 | 93 | Taking down carefully copper/aluminium point wiring (light ,fan, socket or power ) complete (fittings such as switches , ceiling roses, pendants, regulators, sockets etc and making good disturbed surfaces of walls, floors etc all as specified and directed. | 60 | Each \nPoint | |
94 | 94 | M & L point wiring with 1.5 Sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor cable in concealed PVC surface conduit 20mm or higher dia , complete with all accessories /fitting and Ist class hard wood (Shisham) terminal switch board of suitable size with 3 mm thick plastic laminated hard gloosy surface sheet top cover open recessed on all and brass screw and washer including unsheathed single core PVC insulated cable green in colour 1.5 Sqmm multistranded copper conductor as contineous earth wire and connecting to earth dolly complete all as specified and directed | |||
95 | 95 | One light point/Fan point/bell point controlled by one way switch of 5/6 Amps | 41 | Each Point | |
96 | 96 | One 3/5 pin socket outlet point on same board controlled by one way switch of 5 Amps but with cables 2.5 sqmm size | 3 | Each Point | |
97 | 97 | One 3/5 pin socket outlet point on independent board controlled by one way switch of 5 Amps but with cables 2.5 Sqmm size | 8 | Each Point | |
98 | 98 | M & L point wiring with 4.0 Sqmm (Nominal cross sectional area) single core PVC insulated with PVC unsheathed multi stranded copper conductor cable in PVC conduit not less than 20mm dia , in concealed/open surface type complete with all accessories /fitting and Ist class hard wood (Shisham) terminal switch board of suitable size with 3 mm thick plastic laminated hard gloosy surface sheet top cover open recessed on all and brass screw and washer including unsheathed single core PVC insulated cable green in colour 4 Sqmm multistranded copper conductor cable as earth wire and connecting to earth dolly complete all as specified and directed for 3/5 pin , 15/16 Amps power socket controlled by one , one way switch of 15/16 Amps complete all as specified | 8 | Each Point | |
99 | 99 | S & F switch piano flush button single pole one way 5Amps complete all as specified and directed. | 52 | Each | |
100 | 100 | S & F switch piano flush button single pole one way 15Amps complete all as specified and directed. | 8 | Each | |
101 | 101 | S & F socket out let 3 pin 5/6 Amps flush type complete all as specified and directed | 11 | Each | |
102 | 102 | S & F socket out let two in one 3 pin 5/6 Amps and 3 pin 15/16 Amps , flush type, non shutters, non interlocking complete all as specified and directed | 8 | Each | |
103 | 103 | S & F Ceiling rose , surface bakelite , AC , 60x30mm , 3 terminals complete all as specified and directed | 40 | Each | |
104 | 104 | S & F lamp holder PVC /poly carbonated type with back plate suitable for pendants /angular /batten fittings complete all as specified and directed | 18 | Each | |
105 | 105 | S & F in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed. | 8 | Each | |
106 | 106 | S & F in repairs sheet metal enclosure for DB SPN 8 way with 200 Amp rated bus bar 240 Volts , single door suitable for housing MCBs and isolators complete all as specified and directed. | 3 | Each | |
107 | 107 | S & F in repairs MCB SP 6 to 40 Amps ,240volts 10KA complete all as specified and directed \n | 24 | Each | |
108 | 108 | S & F in repairs MCB DP 40 Amps ,240volts 10KA complete all as specified and directed \n | 15 | Each | |
109 | 109 | S & F in repairs MCB TPN 63Amps ,415 volts, 10 KA complete all as specified and directed | 4 | Each | |
110 | 110 | S & F in replacement PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete all as specified and directed | 40 | Each | |
111 | 111 | Supply and fixing in replacement and testing complete as existing poles/walls SMD LED Street light luminaires of 45 watts System wattage for energy saving having IP-66 degree of protection ,With minimum system efficiency as > 85 % ,made of Pressure die cast aluminum housing powder coated in graphite grey and heat resistant thoughned glass with excellent thermal management including PVC cable connector. LED's should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120 - 270 VAC , THD <10% , P.F >.95 .The fitting should have in built surge protector of 5 KV, complete all as specified. \n | 6 | Each | |
112 | 112 | M & L for Sub main wiring with 2 runs of 6 Sqmm and one runs of 4 Sqmm copper cable multistanded in and including PVC conduit 20 mm dai or higher size in concealed surface providing necessary clamps, bends, accessories, screw, thimble and connected to MCB / DB box / Mains witches etc including taking down old sub main wiring with all necessary fittings complete all as specified and directed. | 40 | RM | |
113 | 113 | S & F PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete all as specified and directed | 40 | Each | |
114 | 114 | Supply and fixing and testing complete as existing poles/walls SMD LED Street light luminaires of 45 watts System wattage for energy saving having IP-66 degree of protection ,With minimum system efficiency as > 85 % ,made of Pressure die cast aluminum housing powder coated in graphite grey and heat resistant thoughned glass with excellent thermal management including PVC cable connector. LED's should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120 - 270 VAC , THD <10% , P.F >.95 .The fitting should have in built surge protector of 5 KV, complete all as specified. \n | 6 | Each | |
115 | 115 | Disconnecting / taking down carefully ceiling fan from existing position, dismantling, overhauling and cleaning throughly, oiling / greasing and rehanging at same or new locations after replacing split pins, check nuts, rubber seal etc and re-assemble duly connected with new PVC three core flexible copper conductor cable of size 23/.0076, complete testing & specified all as directed. \nNote: Spare parts will be measured and paid separately under respective items as supply only as mentioned below. | 25 | Each\nJob | |
116 | 116 | M & L for taking out burnt copper winding from Ceiling Fan of 1200mm size and rewinding with existing / same guage of super enammeled copper winding wire complete and refixing at same or new location all as specified and directed. | 20 | Each\nJob | |
117 | 117 | Supply only Ball bearing for Ceiling fan | 25 | Each | |
118 | 118 | Supply only Capacitor 2.5 Mfd +- 5% 440 Volt AC 50 Hz | 25 | Each | |
119 | 119 | Disconnecting / taking down carefully Exhaust Fan of any size from existing position , dismantling , overhauling and cleaning throughly, oiling/greasing and rehanging after replacing split pins , check nuts, rubber seal bushes etc and re- assemble duly connected with new PVC three core flexible copper conductor cable of size 23/.0076, complete testing & specified all as directed. \nNote: Spare parts will be measured and paid separately under respective items as supply only as mentioned below. | 2 | Each\nJob | |
120 | 120 | M & L for taking out burnt copper winding from exhaust Fan of any size/type and rewinding with existing /same guage of super enammeled copper wire complete all as specified and directed. | 2 | Each\nJob | |
121 | 121 | Supply only capacitor 4 Mfd +/- 5% 440 Volt AC 50 Hz or suitable one | 2 | Each | |
122 | 122 | Taking down carefully flate-plate solar collector storage solar water heater of capacity up to 100 ltr dismantling inner tank and outer tank, pipe assembly, cleaning throughly with descalling liquid compound, overhauling complete to ensure free and constant flow of water through outlet, welding of inner tank if required at site, laser/ultrasonic welding for bonding fin and raiser tube, repair of copper bracing for bonding of header and raiser making leak proof, repair & repalcement of back and side insulation material, rethreading of inlet/outlet pipe 20 mm dia , reassembling the same at existing location including necessary fasteners to ensure proper safety as reqd at site, repair/ welding of MS structure for collector stand, testing and commissioning after re-installation at site complete all as specified and directed. \nNote: 1. Unsericeable spare parts will be measured and paid separately under respective items under supply only.\n2. Cost of descalling liquid and welding any type (if required) shall be deemed to inclusive in quoted unit rate.\n3. Unserviceable items retrived form this job shall be abstracted under sch of credit. | 1 | Each Job | |
123 | 123 | Supply only heating element of 3.0 KW for solar water heater (as per sample) | 1 | Each | |
124 | 124 | Supply only Thermostat for solar water heater 100 Ltr | 1 | Each | |
125 | 125 | Supply only insulating material for flate-plate solar collector water heating system made with Rock wool/ Mineral wool/ Fibre Glass wool with 48Kg/cu.mt density for better heat prevention | 2 | Kg | |
126 | 126 | Supply only Heavy duty nylon threaded flexible PVC/CPVC connection pipe 25 mm dia suitable for both hot & cold watrer supply of solar water heater | 2 | RM | |
127 | 127 | Supply only GI/brass adjustable scew clamp as per sample | 2 | Each | |
128 | 128 | Supply only GI Elbow 15mm | 2 | Each | |
129 | 129 | Supply only GI Socket 15 mm | 1 | Each | |
130 | 130 | Supply only GI Union 15mm | 1 | Each | |
131 | 131 | Supply only GI Nipple 15 mm | 2 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy