Job Work Addn/Altn/Improvement Of Electrification In Bldg No 183/02 Defence Colony Under Ge East Lucknow, GE (EAST) LUCKNOW-Uttar Pradesh

Military Engineer Services-MES has published Job Work Addn/Altn/Improvement Of Electrification In Bldg No 183/02 Defence Colony Under Ge East Lucknow. Submission Date for this Tender is 18-01-2021. Bolts Tenders in GE (EAST) LUCKNOW Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26589402
Job Work Addn/Altn/Improvement Of Electrification In Bldg No 183/02 Defence Colony Under Ge East Lucknow
Open Tender
Indian
Uttar Pradesh
GE (EAST) LUCKNOW
18-01-2021

Tender Details

Job Work Addn/Altn/Improvement Of Electrification In Bldg No 183/02 Defence Colony Under Ge East Lucknow , ( I ) Taking Down Carefully Copper/Aluminium Point Wiring ( Light , Fan , Socket , Bell Or Power ) Complete Including All Electrical Fittings & Fixtures ( Dbs , Submain , Cables Etc ) And Making Good Disturbed Surfaces Of Wall , Floor Etc And Matching Wth Original Colour Of Wall , Complete , All As Specified & Directed . - 61 Per Point ( Ii ) Taking Down Carefully Copper/Aluminium Sub Main Wiring From Existing Concealed Pvc Conduit Complete And Making Good Disturbed Surfaces Of Wall , Floor Etc And Matching Wth Original Colour Of Wall All As Specified . - 107 Rm ( Iii ) M&L For One Light/Fan/Exhaust Fan Point Wiring Controlled By One Switch With Pvc Insulated Unsheathed Multi Stranded Copper Conductor ( Frls ) Of Size 1 . 5 Sqmm ( For Phase Colour Code Red And For Neutral Colour Code Black ) And One Run Of Size 1 . 5 Sqmm Pvc Insulated Unsheathed Multi Stranded Copper Conductor ( Frls ) ( As Earth Wire , Colour Code Green ) And Connected To Common Earth Dolly All As Specified . , Drawn Through In And Including Concealed Pvc Conduit Medium Grade , Isi Marked Not Less Than 19 . 5 Mm / 20 Mm Dia ( Make: Polycab/Caps/Akg ) Along With Conduit Fixing Accessories And With Pressed Steel Terminal Box For Mounting Of Modular Inner Plates Of Thickness 1 . 6 Mm With Outer Modular Plates Upto 12 Modules ( Make: Crabtree ) For Provision Of Modular Switches/Regulators As Per Specified Ssr And As Directed By Engineer- In- Charge . Make Of Wiring Cable:- Polycab/Rr Kable/Havells/Finolex . Note:- After Rewiring Cutting Chasing Portion Should Be Matched With Existing Finishes Of Walls - 35 Per Point ( Iv ) All As Per Item No 3 Above But 5 Amp Socket Outlet , Independent . - 10 Per Point ( V ) All As Per Item No 3 Above But On The Same Board . - 10 Per Point ( Vi ) All As Per Item No 3 Above But For One Light Point Controlled By Two , 2- Way Switch . - 01 Per Point ( Vii ) All As Per Item No 3 Above But 2 . 5 Sq Mm Wire For One 15 Amps Socket Outlet Independent With Continuous Pvc Insulated Single Core Green Colour Copper Earth Wire Of Size 1 . 5 Sq Mm Connected To Common Earth Dolly . - 05 Per Point ( Viii ) S&F Switch Piano Flush Type 5 Amp One Way , Single Pole , 240 Volts All As Specified . - 55 Each ( Ix ) S&F Switch Piano Type 5 Amp , 2 Way , 240 Volts All As Specified . - 02 Each ( X ) S&F In Repairs Socket Outlet 5 Amp , 5 Pin , 240 Volt , Flush Type , All As Specified And Directed . - 20 Each ( Xi ) S&F In Repairs Switch Socket Outlet , Two In One 5 & 15 Amp , 6 Pin , Multipurpose Combination , All As Specified . - 05 Each ( Xii ) S&Fixing In Replacement Ceiling Rose Two Or Three Terminals Surfaces Bakelite65 X 50Mm Size All As Specified . Make :- Anchor - 35 Each Continued To Next Coloumn , ( Xiii ) S&Fixing In Replacement Lamp Holder Bakelite With Back Plate Suitable For Batten Fittings All As Specified . Make: Anchor - 03 Each ( Xiv ) S&F Ceiling Fan Regulator Electronic Stepped Type For 1200/1400 Mm Sweep . Make:- Anchor/Ssk/Bajaj . - 03 Each ( Xv ) Supply And Fix In Replacement Of Single Side Connection Led T8 Tube Light Rod 20 Watt , 6500K Of Four Feet Long Into And Including Led Tube Light Fixture Of Four Feet Long With T8 Push Fit Type Holders , Connector Block , End Caps , Etc Including Connecting Up Complete All As Specified And Directed . Make : Crompton , Cat No : Igp131lt8-16& Lt8-20-865-2 Or Equivalent In Havells , Cat No : Regalbattent8upt01x22wssbs & Photonultra1213t8sstl20wled865spc , Philips Cat No Tmc 100 1Xt Led /Mas Led Tube 1200 Mm 18 W 865 T8 I - 2100 Lumen - 07 Each ( Xvi ) Supply And Fixing In Repairs Led Street Light Fitting 1 X 45 Watt , Water Proof Confirm To Ip-65 Including One Number Ms Clamps Made Of 25X3 Mm Flat Iron With Bracket Of Gi Pipe Light Grade 25 Mm Dia And Length Not Less Than 1 . 2 Mtr End Of Gi Pipe Suitable For Street Light Fitting . Connecting With Three Core Copper Flexible Wire 23/0 . 0076 . Cat Part No-Endurapealneosl45led757pasyopc/ Philips/C&G - 02 Each ( Xvii ) Supply And Fixing As In Repair Mcb Db Spn ( Double Door ) 8 Ways Including Bus Bar Neutral Link , Earth Bar And Din Rail , Recessed With Wall Surfaces By Chase Cutting And Making Good Surfaces Of Wall All As Specified And Directed By The Engr-In-Charge . - 02 Each ( Xviii ) Supply And Fix Single Pole And Neutral Sheet Metal Enclosure With Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb 20 Amps All As Specified And Directed . Make - Legrand Cat No-6078 41 Or Equivalent Approved - 01 Each ( Xix ) Supply And Fixing In Replacement Mcb , Single Pole , 240 Volts , Of Capacity ( 6-32 Amps ) As Ordered Breaking Capacity 10 Ka . - 02 Each ( Xx ) Supply And Fixing In Repair Mcb Spn , 40 To 63 Amps , 240 Volts , Breaking Capacity 10Ka Complete All As Directed . - 02 Each ( Xxi ) M&L For Sub Main Wiring With Pvc Insulated Unsheathed Cable With Copper Conductor Multi Strand Two Single Core 6 Sq Mm And One Run Of 4 Sq Mm Pvc Insulated Green Colour Earth Continuity Wire Drawn Through In And Including 25 Mm Dia Pvc Concealed Conduit All As Specified . Make- Anchor /Seiko /Havells /Paragon /Finolex/Hpl/Plaza - 20 Rm ( Xxii ) All As Per Item No . 21 But Two Single Core 4 Sqmm Including 2 . 5 Sqmm Pvc Insulated Unsheathed Stranded Copper Conductor As Earth Wire All As Specified . Make- Anchor /Seiko /Havells /Paragon /Finolex/Hpl/Plaza . - 63 Rm ( Xxiii ) All As Per Item No . 21 But Two Single Core 2 . 5 Sqmm Including 1 . 5 Sqmm Pvc Insulated Unsheathed Stranded Copper Conductor As Earth Wire All As Specified . Make- Anchor /Seiko /Havells /Paragon /Finolex/Hpl/Plaza - 24 Rm ( Xxiv ) Renewal Of Earthing Complete With Galvanized Steel Earth Plate Electrode 600X600x6 . 0Mm Thick , Buried Directly In Ground ( Earth Pit Not Less Than 2 . 25 Mtr , Deep Below Ground Level ) With Top Edge Of The Plate Not Less 1 . 5 Mtr Deep Below Normal Ground Level Connected To Galvanized Earth Lead Wire 4 . 0Mm Dia By Means Of Nut , Bolts , Check Nut 7 Washer Of Galvanized Iron Or Of Steel , Earth Lead Protected By 15 Mm Dia Gi Pipe Light Grade Watering Pipe 20Mm Dia Gi Wire Meshed Funnel Alternate Layer Of Char Coal And Salt Pcc Chamber , Reassed For And Including Rcc Cover Including All Necessary Excavation & Earth Work , Earth Wire Connected To Main Switch Board , Testing The Earthing After Completion All As Specified And Shown In Electric Plate No 3 Of Mes Ssr Part-I 2009 Print And As Directed . - 01 Each

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work : Job Work for Addn/Altn /improvement of electrification in bldg no 183/02defence colony under GE(East) Lucknow.
Sl. No. Item Description Item Code / Make Quantity Units
1 1.01 (i) Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed. - 61 Per Point\n\n(ii) Taking down carefully copper/aluminium sub main wiring from existing concealed PVC conduit complete and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall all as specified. - 107 RM\n\n(iii) M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and including concealed PVC Conduit medium grade, ISI marked not less than 19.5 mm / 20 mm dia (Make: Polycab/Caps/AKG) along with conduit fixing accessories and with pressed steel terminal box for mounting of modular inner plates of thickness 1.6 mm with outer modular plates upto 12 modules (Make: Crabtree) for provision of modular switches/regulators as per specified SSR and as directed by Engineer- in- Charge. Make of wiring cable:- Polycab/RR Kable/Havells/Finolex. NOTE:- After rewiring cutting chasing portion should be matched with existing finishes of walls - 35 Per Point\n\n(iv) All as per item No 3 above but 5 Amp socket outlet, independent. - 10 Per Point\n(v) All as per item No 3 above but on the same board. - 10 per point\n(vi) All as per item No 3 above but for one light point controlled by two, 2- way switch. - 01 per point\n(vii) All as per item No 3 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly. - 05 Per point\n(viii) S&F switch piano flush type 5 Amp one way, single pole, 240 volts all as specified. - 55 Each\n(ix) S&F switch piano type 5 Amp, 2 way, 240 volts all as specified. - 02 Each\n(x) S&F in repairs socket outlet 5 Amp, 5 Pin, 240 volt, flush type, all as specified and directed. - 20 Each\n(xi) S&F in repairs switch socket outlet, two in one 5 & 15 Amp, 6 pin, multipurpose combination, all as specified. - 05 Each\n(xii) S&Fixing in Replacement ceiling rose two or three terminals surfaces bakelite65 x 50mm size all as specified. Make :- Anchor - 35 Each\n\n Continued to next coloumn 1 Complete one Job
2 1.02 (xiii) S&Fixing in Replacement lamp holder bakelite with back plate suitable for batten fittings all as specified. Make: Anchor - 03 Each\n(xiv) S&F ceiling fan regulator electronic Stepped type for 1200/1400 mm sweep. Make:- Anchor/SSK/Bajaj. - 03 Each\n(xv) Supply and fix in replacement of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into and including LED tube light fixture of four feet long with T8 push fit type holders, connector block, end caps, etc including connecting up complete all as specified and directed. Make : Crompton, Cat No : IGP131LT8-16& LT8-20-865-2 or equivalent in Havells, Cat No : REGALBATTENT8UPT01X22WSSBS & PHOTONULTRA1213T8SSTL20WLED865SPC,philips cat no TMC 100 1xT LED /MAS LED tube 1200 mm 18 w 865 T8 I - 2100 Lumen - 07 Each \n(xvi) Supply and fixing in repairs LED street light fitting 1 x 45 watt , water proof confirm to IP-65 including one number MS clamps made of 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting. connecting with three core copper flexible wire 23/0.0076. Cat part no-ENDURAPEALNEOSL45LED757PASYOPC/ philips/C&G - 02 Each\n\n(xvii) Supply and fixing as in repair MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge. - 02 Each \n(xviii) Supply and fix Single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified and directed. Make - Legrand Cat No-6078 41 or equivalent approved - 01 Each \n(xix) Supply and Fixing in replacement MCB, single pole, 240 Volts, of capacity (6-32 Amps) as ordered breaking capacity 10 KA. - 02 Each\n(xx) Supply and fixing in repair MCB SPN, 40 to 63 Amps, 240 Volts , breaking capacity 10KA complete all as directed. - 02 Each\n(xxi) M&L for sub main wiring with PVC insulated unsheathed cable with copper conductor multi strand two single core 6 sq mm and one run of 4 sq mm PVC insulated green colour earth continuity wire drawn through in and including 25 mm dia PVC concealed conduit all as specified. Make- Anchor /Seiko /Havells /Paragon /finolex/HPL/Plaza - 20 RM\n(xxii) All as per item No. 21 but two single core 4 sqmm including 2.5 Sqmm PVC insulated unsheathed stranded copper conductor as earth wire all as specified. Make- Anchor /Seiko /Havells /Paragon /finolex/HPL/Plaza. - 63 RM\n(xxiii) All as per item No. 21 but two single core 2.5 sqmm including 1.5 Sqmm PVC insulated unsheathed stranded copper conductor as earth wire all as specified. Make- Anchor /Seiko /Havells /Paragon /finolex/HPL/Plaza - 24 RM\n(xxiv) Renewal of Earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr, deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanized earth lead wire 4.0mm dia by means of nut, bolts, check nut 7 washer of galvanized iron or of steel, earth lead protected by 15 mm dia GI pipe light grade watering pipe 20mm dia GI wire meshed funnel alternate layer of char coal and salt PCC chamber, reassed for and including RCC cover including all necessary excavation & earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR part-I 2009 print and as directed. - 01 Each\n\n
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail