Carrying Electrification Work At Kscdc Building , Elathur- Kozhikode . , Elathur- Kozhikode.-Kerala

Kerala Agro Industries Corporation Limited-KAIC has published Carrying Electrification Work At Kscdc Building , Elathur- Kozhikode . . Submission Date for this Tender is 22-01-2021. Electrification Work Tenders in Elathur- Kozhikode. Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

26589193
Carrying Electrification Work At Kscdc Building , Elathur- Kozhikode .
Open Tender
Indian
Kerala
Elathur- Kozhikode.
22-01-2021

Tender Details

Carrying Electrification Work At Kscdc Building , Elathur- Kozhikode .

Key Value

Document Fees
INR 2380 /-
EMD
INR 14325.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Electrification of Factory Building
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Particulars 1
2 1.01 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated\ncopper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch,\nmodular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper\nconductor single core cable etc as required.Group C\n 1.01 63 points
3 1.02 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A 1.02 24 points
4 1.03 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without\nindependent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in\nsurface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper\nconductor single core cable etc. as required.Group B 1.03 21 points
5 1.04 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 1.04 18 point
6 1.05 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the\nexisting surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 1.05 67 m
7 1.06 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm 1.06 444 m
8 1.07 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm 1.07 359 m
9 1.08 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm 1.08 82 m
10 1.09 \nSupplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/\nrecess including cutting the wall and making good the same in case of recessed conduit as required.20\nmm\n 1.09 762 m
11 1.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 1.1 190 m
12 1.11 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 1.11 19 each
13 1.12 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 1.12 3 each
14 1.13 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 1.13 13 each
15 1.14 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 1.14 3 each
16 1.15 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1.15 14 each
17 1.16 \nSupplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular\nplate as required. 1.16 12 each
18 1.17 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 1.17 10 each
19 1.18 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. 1.18 67 each
20 2 2 MCCB, MCB & DB's 2
21 2.01 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required • (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (8 + 36) double cover TPN vertical DB 2.01 1 each
22 2.02 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) 2.02 1 each
23 2.03 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 2.03 21 each
24 2.04 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 2.04 1 each
25 2.05 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 2.05 11 each
26 2.06 Supplying and fixing 63 A four pole , 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A four pole MCB 2.06 1 each
27 2.07 Supplying and fixing 25 A four pole , 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.25A four pole MCB. 2.07 3 each
28 2.08 Supplying and fixing 16 A four pole , 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.16A four pole MCB. 2.08 3 each
29 2.09 \nSupplying and fixing following rating, four pole, (three phase and neutral), 415 V, RCBO, having a sensitivity current 100mA in the existing MCB DB complete with connections, testing and commissioning\netc. as required.63A four pole RCBO 100mA. 2.09 1 each
30 2.1 Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, RCBO, having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25A four pole RCBO 30mA. 2.1 1 each
31 2.11 \nSupplying and fixing 125A FP onload change over switch in suitable sheet steel enclosure etc as\nrequired 2.11 1 each
32 2.12 \nSupplying and fixing of four module thermoplastic MCB DB of size<br>126x228x111mm on surface/\nrecess for fixing FP MCB complete with<br>connections, testing and commissioning etc. as\nrequired.(Make: Hensel / eq) 2.12 8 each
33 2.13 Supply and fixing Motor starters of the following ratings Single phase DOL starters for 0.25HP to 3HP motor 2.13 1 each
34 2.14 \nSupply and fixing Motor starters of the following ratings.<br>Three phase DOL starters for 0.25HP to 7.5\nHP motor 2.14 6 each
35 2.15 Supply and fixing Motor starters of the following ratings. Fully automatic star delta starter for 15HP motor 2.15 1 each
36 3 3 MV cabling and Termination 3
37 3.01 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm 3.01 120 m
38 3.02 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp 3.02 25 m
39 3.03 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 3.03 10 m
40 3.04 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 3.04 37 m
41 3.05 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp 3.05 80 m
42 3.06 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) 3.06 4 set
43 3.07 Supplying and making outdoor end termination with cast resin compound including aluminiumlugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm 3.07 2 each
44 3.08 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 3.08 2 set
45 3.09 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) 3.09 2 set
46 3.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm) 3.1 2 set
47 4 Earthing 4
48 4.01 \nEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding\nmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.\nwith charcoal/ coke and salt as required. 4.01 3 set
49 4.02 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 4.02 346 m
50 4.03 \nSupply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving\nconnection as required.25 mm X 3 mm CU. strip <br><br> 4.03 30 m
51 5 5 LIGHT FIXTURES AND FAN 5
52 5.01 \nInstallation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all\ntypes, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5\nsq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.\n 5.01 107 each
53 5.02 Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep 5.02 5 each
54 5.03 Conveyance installation testing and commissioning ceiling fan of all sizes using standard accessories excluding resistance type regulator wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or extending the original wiring etc. as required. 5.03 14 each
55 5.04 Supply of 20±2W Surface mounted LED tube light fixture (IP20) with a lumen output minimum 100lumen/Watt suitable for indoor applications including including all connections etc as required. 5.04 8 each
56 5.05 Supply of 15±2W Recess mounted square LED down light fixture (IP20), 5700 K colour temperature, with a lumen output minimum 100lumen/Watt, including all connections as required.(Make -Wipro - Helix - LD91-201-XXX-65-XX) or Equivalent.) 5.05 59 each
57 5.06 Supply of 12±2W surface mounted square LED down light fixture (IP20), 5700 K colour temperature, with a lumen output minimum 100lumen/Watt, including all connections as required.(Make -Philips sleek surface -SM250C LED12S-6500PSU WH) or Equivalent.) 5.06 34 each
58 5.07 Supply of 10±2W LED surface mounted bulk head light fixture (IP20) ,5700K colour temperature,with a lumen output minimum 100lumen/Watt, including all connections as required.. (Make - Wipro Bulk HeadLW07-141-XXX-57-XX or equivalent.) 5.07 6 each
59 5.08 \nSupply of 1200mm sweep- 5 star rated (BLDC), ceiling fan using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.<br>1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C (Make - Crompton greaves Energion HS - or equivalent 5.08 14 each
60 5.09 \nSupply of 250 mm light duty exhaust fan in plastic frame working on 230 V A/C. with accessories etc as\nrequired.(Make - Crompton greaves- Brisk Air 10" or equivalen 5.09 4 each
61 5.1 Supply of 380 mm heavy duty exhaust fan in plastic frame working on 230 V A/C. with accessories etc as required.(Make - Crompton greaves- EXHD380-6-1 or equivalent) 5.1 1 each
62 6 6 PANEL BOARD 6
63 6.01 Supply, fabrication and installation of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 using 16 SWG galvano sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly..<br>Metering panel.<br>Meters and indication lamps : RYB indication with control fuses <br>100A porcelain fuse carrier with 100 A porcelain fuse links 3 Nos.<br>125A TPN SFU with 100A Fuse -1 No.<br>(Rate of Energy meter and its CT are not included in the above rate)\n 6.01 1 each
64 6.02 Supply, fabrication and installation of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 using 16 SWG galvano sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly.<br><br>Main Switch Board:<br>Incomer : 125A FP MCCB 25kA - Thermal magnetic release - 1 No.<br>Meters and indication lamps : RYB indication, MFM with control fuses and CTs - 1\nset.<br>Busbar : 25x10 mm Al busbars for 3 phases and neutral and 25x3mm Cu busbar for earthing.<br>Outgoings - 63A, 16 kA TPN MCCB - 2 No.<br>40A, 16 kA TPN MCCB - 1 No.<br>100A,\n16 kA TPN MCCB - 1 No 6.02 1 each
65 7 DISMANTLING WORK 7
66 7.01 Labour charges for dismantling existing PVC Conduit of size 20/25/32 mm etc as required. 7.01 200 m
67 7.02 Labour charges for dismantling existing PVC insulated copper wire of size 1.5/2.5/4/6 sq mm etc as required. 7.02 200 m
68 7.03 Labour charges for dismantling existing light points etc as required 7.03 6 each
69 7.04 \nLabour charges for dismantling existing switch board etc as required. 7.04 5 each
70 7.05 Labour charges for dismantling existing meter board etc as required. 7.05 2 each
71 7.06 Labour charges for dismantling existing distribution board etc as required 7.06 1 each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail