Supply, Installation & Electrification Of Irrigation Subersible Pumps Sets With Accessories Suitable For 165 Mm Dia Borewells In Various Locations In Belagavi District Of Karnataka Under Ganga Kalyana Scheme For The Year 2019-20., Bangalore-Karnataka

D. Devaraj URS Backward Classes Development Corporation has published Supply, Installation & Electrification Of Irrigation Subersible Pumps Sets With Accessories Suitable For 165 Mm Dia Borewells In Various Locations In Belagavi District Of Karnataka Under Ganga Kalyana Scheme For The Year 2019-20.. Submission Date for this Tender is 12-02-2021. Electrification Work Tenders in Bangalore Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

26569806
Supply, Installation & Electrification Of Irrigation Subersible Pumps Sets With Accessories Suitable For 165 Mm Dia Borewells In Various Locations In Belagavi District Of Karnataka Under Ganga Kalyana Scheme For The Year 2019-20.
Open Tender
Indian
Karnataka
Bangalore
12-02-2021

Tender Details

Supply, Installation & Electrification Of Irrigation Subersible Pumps Sets With Accessories Suitable For 165 Mm Dia Borewells In Various Locations In Belagavi District Of Karnataka Under Ganga Kalyana Scheme For The Year 2019-20. 1. Submersible Pump Sets Including Motor 150Mm Dia Conforming To Bis 8034(2002) For Pump Sets And Bis 9283 (1995) For Motors With Accessories: As Per Following Specification Mentioned Below For All Capacity Of Pump And Motors.5 Hp 10 Stage, 2. 5 Hp 14 Stage, 3. 7.5 Hp 12 Stage, 4. 7.5 Hp 15 Stage, 5. 10Hp 20 Stage, 6. 10Hp 30 Stage, 7. 12.5 Hp 30 Stage, 8. 15 Hp 30 Stage, 9. 17.5 Hp 35 Stage, 10. 20 Hp 30 Stage, 11. 20 Hp 40 Stage, 12. 50Mm Nb G.I Pipe Class B As Per Isi 1239 / 90., 13. Collar:A) Heavy Collar Should Be 100Mm Long And Weigh Not Less Than 1200 Gms. (For Installations Of 152 Meters Depth & Above), 14. B) Light Collar Should Be 90Mm Long And Weigh Not Less Than 900 Gms . (For Installations Less Than 152 Meters Depth), 15. Upvc 50 M.M Column Pipe Wall Thickness Should Be Above 4.00Mm Sulphated Ash Content Should Be Less Than 5.00% Vicat Softening Point Should Be Above 85 0 C., 16. Gi Adaptor Gi Adaptor Suitable For 50Mm Nb Submersible Upvc Column Pipes With Pullout Strengths Not Less Than 33000 Newtons., 17. Submersible Flat Cable: Pvc Insulated Submersible Cable Of Flat 3.00 Core (Sheathed) Of Nominal Cross Sectional Area 2.5/4.00 Sq Mm As Per Is:694-2010 With Latest Amendments. 1X3x2.50 Sq.Mm, 18. 1X3x4.00 Sq.Mm, 19. 1X3x6.00 Sq.Mm, 20. Gate Valve Weighing Not Lesss Than 1500 Gms Suitable For Agricultural Irrigation Application, 21. Non Return Valve Cast Iron Non Return Valve Weighing Not Lesss Than 2500 Gms Suitable For Agricultural Irrigation Application, 22. Gi Bend Gi Bend 50 Nb Class B, 23. Borewell Cap Borewell Cap (Including Bolts And Nuts) Weighning Not Less Than 800 Grms., 24. Clamp Set: Supporting Clamps (Two Pairs), Pvc Cable Locking Strips (2 Nos Per Length) Heavy (For Installation Of 152 Mtrs & Above) Each Pair Weighing Not Less Than 4000 Grms Of 350Mmx60mmx10mm Size., 25. G.I. Nipple Pipe 0.5 Mtrs Length Of B-Class Gi Nipple Pipe., 26. Agricultural Staarter Panel Board Unit (Outdoor) (Page 26) Up To 6 Hp, 27. Up To 6 Hp -10 Hp, 28. Up To 12.5 Hp -20 Hp, 29. Power Capacitor, 1 Kvar To 30 Kvar, 440 Volts As Per Ifc:60831-1+2 And Is:13340-41 As Per Is 2834/86 And Approved By Kptcl, 30. M.C.B Is Of K-Curve (For Submersible Pump Application 10.4 1N - 15.6 1N) As Per Iec:60947-2 And Certified At Any Nabl Accredited Lab. It Should Have Rated Short Circuit Of 10Ka. (Miniature Circuit Breakers) Of 6/10/16/20/25/40 Amps With Sealable Box As Per Is 8828/78, 31. Pvc Insulated Sheathed Steel Wire/Steel Tape, Armoured Ug Cable Wit Pvc Outer Sheeting 1.1 Kv Conforming To Is: 1554(1988) With Latest Amendments From Escom Pole To The Meter Board :For 3.5X10 Sq Mm, 32. 3.5 X 16 Sq Mm, 33. Gi Pipe For Earthing: G.I. Pipe: 40Mm Dia ‘A’ Class Earthing Pipe, 34. Pot Head : Cast Iron Pot Heads Suitable For 1.1 Kv Class Ug Cables Filled With Necessary Bitumen/Insulation Etc., For The Cable Size Of 3.5X25 Sq .Mm., 35. Erection Of Pump Sets In The Drill Hole Including Aligning And Balancing With All Necessary Materials And Labour. The Tenderer Has To Arrange At His Own Cost All Erection Tools., 36. Registration Of Applications And Submission Of Wiring Diagrams With Completion Report To Escoms (Excluding Ymd And Meter Deposit Charges Which Are To Be Paid After Sanction), 37. Erection Of Agricultural Submersible Pump Set Starter Panel Board Unit (Outdoor) And Meter Board Units With All Materials And Labour Including Providing Cement Concrete Foundation Bed Etc Complete., 38. Main Connection: Fixing Of 3.5X10/16 Sq.Mm Pvc 1.1 Kv Ug Cable From Escom Pole To Meter Board Unit., 39. Digging Of Trench Of 0.5M Width And 0.5 M Deep And Laying Cable In Trench Including Refilling And Consolidation Of Soil., 40. Erection Of 40 Mm Dia A Class Gi Pipe With Necessary Clamps, Bolts, Nuts, Washers Etc. For Fixing The Pipe On The Escom Pole And Connecting The Ug Cable Up To The Meter Board., 41. Fixing Of Pot Head, 42. Earthing As Per Specifications,

Key Value

Document Fees
INR 550 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Sl No Item Code Item Name Item Description Unit Quantity
1
dbcdc01 Submersible pump sets including motor 150mm dia conforming to BIS 8034(2002) for pump sets and BIS 9283 (1995) for motors with accessories: as per following specification mentioned below for all capacity of pump and motors.5 HP 10 Stage Specification: As per tender doc
Each
1
2
dbcdc02 5 HP 14 Stage Specification: As per tender doc
Each
1
3
dbcdc03 7.5 HP 12 Stage Specification: As per tender doc
Each
1
4
dbcdc04 7.5 HP 15 Stage Specification: As per tender doc
Each
1
5
dbcdc05 10HP 20 Stage Specification: As per tender doc
Each
1
6
dbcdc06 10HP 30 Stage Specification: As per tender doc
Each
1
7
dbcdc07 12.5 HP 30 Stage Specification: As per tender doc
Each
1
8
dbcdc08 15 HP 30 Stage Specification: As per tender doc
Each
1
9
dbcdc09 17.5 HP 35 Stage Specification: As per tender doc
Each
1
10
dbcdc10 20 HP 30 Stage Specification: As per tender doc
Each
1
11
dbcdc11 20 HP 40 Stage Specification: As per tender doc
Each
1
12
dbcdc12 50mm NB G.I Pipe Class B as per ISI 1239 / 90. Specification: As per tender doc
Per Mtr
1
13
dbcdc13 Collar:a) Heavy Collar should be 100mm long and weigh not less than 1200 gms. (for installations of 152 meters depth & above) Specification: As per tender doc
Each
1
14
dbcdc14 b) Light Collar should be 90mm long and weigh not less than 900 gms . (for installations less than 152 meters depth) Specification: As per tender doc
Each
1
15
dbcdc15 UPVC 50 m.m column pipe Wall thickness should be above 4.00mm Sulphated ash content should be less than 5.00% Vicat softening point should be above 85 0 c. Specification: As per tender doc
Per Mtr
1
16
dbcdc16 GI adaptor GI adaptor suitable for 50mm NB submersible uPVC column pipes with pullout strengths not less than 33000 newtons. Specification: As per tender doc
Each
1
17
dbcdc17 Submersible Flat Cable: PVC insulated Submersible cable of flat 3.00 core (sheathed) of nominal cross sectional area 2.5/4.00 sq mm as per IS:694-2010 with latest amendments. 1x3x2.50 sq.mm Specification: As per tender doc
Per Mtr
1
18
dbcdc18 1x3x4.00 sq.mm Specification: As per tender doc
Per Mtr
1
19
dbcdc19 1x3x6.00 sq.mm Specification: As per tender doc
Per Mtr
1
20
dbcdc20 Gate Valve weighing not lesss than 1500 gms Suitable for Agricultural Irrigation application Specification: As per tender doc
Each
1
21
dbcdc21 Non Return Valve Cast Iron Non Return Valve weighing not lesss than 2500 gms Suitable for Agricultural Irrigation application Specification: As per tender doc
Each
1
22
dbcdc22 GI Bend GI bend 50 NB Class B Specification: As per tender doc
Each
1
23
dbcdc23 Borewell cap Borewell cap (including bolts and nuts) weighning not less than 800 grms. Specification: As per tender doc
Each
1
24
dbcdc24 Clamp Set: supporting clamps (two pairs), Pvc cable locking strips (2 Nos per length) Heavy (For installation of 152 mtrs & above) Each pair weighing not less than 4000 grms of 350mmX60mmX10mm size. Specification: As per tender doc
per set
1
25
dbcdc25 G.I. Nipple Pipe 0.5 mtrs length of B-Class GI nipple pipe. Specification: As per tender doc
Each
1
26
dbcdc26 Agricultural Staarter panel board Unit (Outdoor) (Page 26) Up to 6 HP Specification: As per tender doc
Each
1
27
dbcdc27 Up to 6 HP -10 HP Specification: As per tender doc
Each
1
28
dbcdc28 Up to 12.5 HP -20 HP Specification: As per tender doc
Each
1
29
dbcdc29 Power Capacitor, 1 KVAr to 30 KVAr, 440 volts as per IFC:60831-1+2 and IS:13340-41 as per IS 2834/86 and approved by KPTCL Specification: As per tender doc
Per KVAR
1
30
dbcdc30 M.C.B is of K-curve (for submersible pump application 10.4 1n - 15.6 1n) as per IEC:60947-2 and certified at any NABL accredited lab. It should have rated short circuit of 10kA. (Miniature Circuit Breakers) of 6/10/16/20/25/40 amps with sealable box as per IS 8828/78 Specification: As per tender doc
Each
1
31
dbcdc31 PVC insulated sheathed steel wire/steel tape, armoured UG cable wit PVC outer sheeting 1.1 KV conforming to IS: 1554(1988) with latest amendments from ESCOM pole to the meter board :for 3.5x10 sq mm Specification: As per tender doc
Per Mtr
1
32
dbcdc32 3.5 x 16 sq mm Specification: As per tender doc
Per Mtr
1
33
dbcdc33 GI Pipe for Earthing: G.I. Pipe: 40mm dia ‘A’ class Earthing Pipe Specification: As per tender doc
Per Mtr
1
34
dbcdc34 Pot head : Cast iron pot heads suitable for 1.1 KV class UG cables filled with necessary bitumen/insulation etc., for the cable size of 3.5x25 sq .mm. Specification: As per tender doc
Each
1
35
dbcdc35 Erection of pump sets in the drill hole including aligning and balancing with all necessary materials and labour. The tenderer has to arrange at his own cost all erection tools. Specification: As per tender doc
Each
1
36
dbcdc36 Registration of Applications and submission of wiring diagrams with completion report to ESCOMS (excluding YMD and meter deposit charges which are to be paid after sanction) Specification: As per tender doc
Per Unit
1
37
dbcdc37 Erection of Agricultural Submersible Pump set starter Panel Board Unit (outdoor) and meter board units with all materials and labour including providing cement concrete foundation bed etc complete. Specification: As per tender doc
Per Unit
1
38
dbcdc38 Main Connection: Fixing of 3.5x10/16 sq.mm PVC 1.1 KV UG cable from ESCOM pole to meter board unit. Specification: As per tender doc
Per Mtr
1
39
dbcdc39 Digging of trench of 0.5m width and 0.5 m deep and laying cable in trench including refilling and consolidation of soil. Specification: As per tender doc
Per Mtr
1
40
dbcdc40 Erection of 40 mm dia A class GI pipe with necessary clamps, bolts, nuts, washers etc. for fixing the pipe on the ESCOM pole and connecting the UG cable up to the meter board. Specification: As per tender doc
Per Mtr
1
41
dbcdc41 Fixing of pot head Specification: As per tender doc
Piece
1
42
dbcdc42 Earthing as per specifications Specification: As per tender doc
Bore
1
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail