Repair Maintenances Of Pumps Motors Starters Submersible Pump Set And Connected Accessories Under Age Em Ii Of Ge Nw Vasco 8327/E8, VASCO-Goa

Military Engineer Services-MES has published Repair Maintenances Of Pumps Motors Starters Submersible Pump Set And Connected Accessories Under Age Em Ii Of Ge Nw Vasco 8327/E8. Submission Date for this Tender is 28-01-2021. Starter Tenders in VASCO Goa. Bidders can get complete Tender details and download the document.




Tender Notice

26559745
Corrigendum : Repair Maintenances Of Pumps Motors Starters Submersible Pump Set And Connected Accessories Under Age Em Ii Of Ge Nw Vasco 8327/E8
Open Tender
Indian
Goa
VASCO
28-01-2021

Tender Details

Repair Maintenances Of Pumps Motors Starters Submersible Pump Set And Connected Accessories Under Age Em Ii Of Ge Nw Vasco 8327/E8

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Jan-2021 Revised Tender Pages Corrigendum Other 28-01-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 23000.0 /-
Tender Value
INR 11.50 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR / MAINTENANCES OF PUMPS, MOTORS, STARTERS, SUBMERSIBLE PUMP SET AND CONNECTED ACCESSORIES UNDER AGE E/M-II OF GE (NW) VASCO.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Material and labour for rewinding by authorised service centre for the burnt unsv electric pumping motor for Repairs to AC, 3 phase, 415 Volts, 50 Hz Electric pumping motor as follows:\n(i) Transport burnt motor to civil work shop. \n(ii) Dismantling motor assembly removing stator and rotar as seperately.\n(iii) Removing burnt / unserviceable windings completely including insulation material and rewinding stator with super enamelled copper wire of standard specification with standard insulation material ,baking complete and re-assembling stator and rotar assembly fixing back to original position at site and testing, commissioning etc complete all as directed for the following capacity of motors:-
2 1.01 (a) Motor of capacity 40 to 60 HP 2 Each Job
3 1.02 (b) Motor of capacity 7.5 to 15 HP 2 Each Job
4 1.03 (c) Motor of capacity 20 to 30 HP 1 Each Job
5 2 S&F DOL/ submersible starter in sheet metal enclouser, AC-3 phase, 415 Volts, 50 Hz, including taking out old unserviceable one all as specified and as directed of the following capacity :-
6 2.01 (a) For Motor 10/7.5 HP, borewell Submersible Starter, AC, 3 Phase, 415 Volts 1 Each
7 2.02 (b) For Motor upto 6 HP, borewell submersible starter, AC, 3 Phase, 415 Volts 1 Each
8 2.03 (c) For Motor upto 7.5 HP, DOL Starter, AC, 3 Phase, 415 Volts 1 Each
9 3 M & L for removing existing Centrifugal pump set motor from base frame after disconnecting electrical connections and varnishing, heating and baking the winding of the motor complete and replacing bearings, grinding the shaft etc complete and reassembling and fixing back to original position and testing, commissioning etc all as directed complete for the following:-\nNote:- \n(i) Replacement of major parts will be measured & paid separately; \n(ii) Any minor part if required will be provided by contractor without any extra cost.
10 3.01 (a) Motor of capacity 50 to 60 HP 1 Job
11 3.02 (b) Motor of capacity 20 to 40 HP 1 Job
12 3.03 (c) Motor of capacity 10 to 20 HP 1 Job
13 3.04 (d) Motor of capacity upto 10 HP 1 Job
14 4 M&L in replacement of coupling set with all accessories for Pump shaft of the following capacity pumping set, including machining, threading, making key slot etc.as directed.
15 4.01 (a) 60/50 HP Pump Set 1 Job
16 4.02 (b) 40/30 HP Pump Set 1 Job
17 4.03 (c) 10/7.5 HP Pump Set 1 Job
18 5 M & L for removing existing unserviceable Fan blade from pump set motor and replacing the same, reassembling and fixing back to original position and testing, commissioning etc all as directed. 1 Job
19 6 Supply only wornout stainless steel Ball bearing of existing size for the following size pumping set complete all as specified & as directed. \n
20 6.01 (a) 60/50 HP Pumpset 3 Set of 2
21 6.02 (b) 40/30 HP Pumpset 3 Set of 2
22 6.03 (c) 20/15/12.5 HP Pumpset 3 Set of 2
23 6.04 (d) 10/7.5 HP Pumpset 3 Set of 2
24 6.05 (e) 5.0/3.0 HP Pumpset 3 Set of 2
25 7 M&L in replacement of Pump shaft for following capacity pumping set, including sleeves, machining, threading, making key slot etc. complete all as directed.
26 7.01 (a) 60/50 HP Pump Set 1 Job
27 7.02 (b) 40/30 HP Pump Set 1 Job
28 8 M&L for replacement of CI impeller of any capacity pumping set all as directed.
29 8.01 (a) 30 to 60 HP Pump Set 1 Job
30 8.02 (b) Upto 30 HP Pump Set 1 Job
31 9 M&L in replacement of gland coupling brass bush for the following pumping set all as directed:-
32 9.01 (a) 60/50 HP Pumpset 1 Each
33 9.02 (b) 40/30 HP Pumpset 1 Each
34 9.03 (c) 15/12.5 HP Pumpset 1 Each
35 9.04 (d) 10/7.5 HP Pumpset 1 Each
36 10 S&F fully automatic star-delta starter in sheet metal enclouser, AC-3 phase, 415 Volts, 50 Hz, with-over load protector, single phase protection relay and electronic timer, including taking out old unserviceable one all as specified and as directed of the following capacity :-
37 10.01 (a) For Motor 12.5/15 HP Capacity 1 Each
38 10.02 (b) For Motor 10/7.5 HP Capacity 1 Each
39 11 Removal of existing submersible pump set of any capacity from the existing borewell (by using any method) of depth upto 200m and transporting to workshop for checking and bringing back after repair, reinstalling of submersible pump set in the borewell including testing and commissioning complete all as directed. Note -: \n(i) The quoted rate shall be deemed to include the cost of any T&P or machinery required for carrying out the work\n(ii) Replacement/Repair will be measured seperately as supply only items 1 Job
40 12 Supply of the following spare parts for submersible pump against above serial item No 11.00 :-
41 12.01 (a) GM impeller 1 Each
42 12.02 (b) GM Neck ring 1 Each
43 12.03 (c) Coupling sleeve 1 Each
44 12.04 (d) MS Stud for pump 1 Each
45 12.05 (e) Bush for submersible motor 1 Each
46 12.06 (f) Bush for pump 1 Each
47 13 Repairs to AC, 3 phase, 415 Volts, 2900 RPM Electric Submersible pumping motor 10 HP against item no 11 above including Dismantling of burnt motor, cutting and taking out burnt stator winding from motor, cleaning the stator and rewinding with super enamelled water proof copper wire of original gauge/size including re-assembling complete all as specified and as directed. 1 Each
48 14 All as per item No. 13.00 above but for 7.5 HP. 2 Each
49 15 All as per item No. 13.00 above but for 5 HP 1 Each
50 16 Removal of existing submersible pump set of any capacity from the existing borewell (by any means) of depth up to 200 mtr and flushing out till clear water is obtained, conducting yield test with 'V' Notch and reinstallation of submersible pump set in the bore well complete all as directed. \nNote : The quoted rate shall be deemed to include the cost of any T&P or machinery required for the complete flushing out of the bore well and testing and commissioning of submersible pumpset. 2 Job
51 17 S & F for submerssible cable ,flat, PVC insulated copper conductor stranded type, 1100 volts grade of size 3 core 6 sq. mm size, including jointing of cable with proper kit, connecting to motor and starter with suitable thimble including dismantling the old one complete all as specified and as directed. 70 RM
52 18 M & L for dismantling sewage pumping set 12.5/20 HP pump set by dismantling of suction & discharge pipe line and motor, cleaning the pump by removing the impeller / repair work / over hauling and replacement of worn out parts all as required to bring the pump in perfect working condition including re-assembling installing, testing and commissioning complete all as specified and directed. \nNote:- \n(i) Cost of minor spare will be born by the contractor\n(ii) Other spares will be measured and paid seperately 2 Each
53 19 Supply only under mentioned worn out parts of sewage pumping set :-
54 19.01 (a) Pump shaft for 20 /12.5 HP pumping set incl machining, threading, making key slot etc. 1 Job
55 19.02 (b) Cast iron impeller for 12.5/20 HP Pump 1 Each
56 19.03 (c) Gland bush for 12.5/20 HP 2 Each
57 19.04 (d) Ball bearing suitable for 12.5/ 20 HP pump set 2 Each
58 19.05 (e) Coupling set for MS shaft of 12.5/ 20 HP pump set 1 Each
59 19.06 (f) Fish Plate bush 1 Each
60 19.07 (g) Nuts & bolts off sizes 4 Kgs
61 20 Supply and fix in repairs Cast Iron Foot valve flanged type, including all necessary fittings ie rubber gasket, nuts & bolts, washers all as specified and directed of the following nominal sizes:-
62 20.01 (a) 150 / 125 mm bore 2 Each
63 20.02 (b) 100 / 80mm bore 2 Each
64 20.03 (c) 65 / 50mm bore 2 Each
65 21 M & L in repairs swing check type reflux(Non- return) valve,cast iron body, single door, both ends flanged type including all necessary fittings ie rubber gasket, nuts & bolts, flanges, washers of the following nominal sizes :-
66 21.01 (a) 150 mm bore 2 Each
67 21.02 (b) 100mm bore 2 Each
68 21.03 (c) 80mm bore 1 Each
69 21.04 (d) 65mm bore 1 Each
70 21.05 (e) 50mm bore 1 Each
71 22 Supply and fix in repairs cast iron sluice valve with stainless steel spindle, class PN-1.6, both ends flanged and drilled and fixed by means of new bolts, nuts and washer of galvanised iron of suitable size , including providing and fixing rubber gasket joints with rubber gasket 3mm thick of the following nominal sizes complete all as specified and directed:-
72 22.01 (a) 200mm bore 1 Each
73 22.02 (b) 150 mm bore 2 Each
74 22.03 (c) 100 mm bore 2 Each
75 22.04 (d) 80 mm bore 1 Each
76 23 Supply and fix in repairs Gun metal gate valve, (heavy duty) with iron wheel head, secrewed both ends for iron pipe all as specified and directed of the following sizes :-
77 23.01 (a) 50 mm bore dia 1 Each
78 23.02 (b) 40 mm bore dia 1 Each
79 23.03 (c) 25 mm bore dia 1 Each
80 23.04 (d) 20 mm bore dia 1 Each
81 23.05 (e) 15 mm bore dia 1 Each
82 24 S & F in repairs pressure gauge, 100 mm size, fitted on delivery side of pump set , including all necessary items required like ball valve & dismantling the old one complete all as specified and as directed.\n 2 Each
83 25 S & F in repairs brass air release cock, fitted on pump set, including dismantling the old one complete all as specified and as directed. 1 Each
84 26 S & F Voltmeter, digital type, 0 to 600V range, flush mounting type, three phase, 415V, AC with 3 phase selector switch, including dismantling old one complete all as specified and as directed. 2 Each
85 27 S & F Powerfactor meter, digital type, 0 to 1 range, flush mounting type, three phase, 415V, AC including all necessary accessories and dismantling old one complete all as specified and as directed. 2 Each
86 28 S & F Ammeter, digital type, 0 to 100 A range, flush mounting type, three phase, 415V, AC with CT's of ratio 100/5 A in all three phases with 3 phase selector switch, including dismantling old one complete all as specified and as directed. 2 Each
87 29 S & F indicator lamp LED type, 230 Volts, AC (different colours for indicating R, Y, B phases) with holder incl dismanlting old one complete all as specified and as directed. 9 Each
88 30 S & F in repairs Single phase preventer and connected to existing strater, suitable for centrifugal pump set of capacity 03 HP to 60 HP. \n 4 Each
89 31 M & L for in repairs electrical rubber chequred mat, size 2 m x 1 m x 19 mm complete all as specified and as directed. 2 Each
90 32 Supply and fixing in repairs power contactor, 3 pole, AC, type MNX 50 complete all as specified and as directed. \n 1 Each
91 33 Supply and fixing in repairs power contactor, 3 pole, AC, type MNX32 complete all as specified and as directed. \n 1 Each
92 34 Supply and fixing in repairs power contactor, 3 pole, AC, type MNX 18 complete all as specified and as directed. \n 1 Each
93 35 Supply and fixing in repairs power contactor, 3 pole, AC, type MNX 12 complete all as specified and as directed. \n 1 Each
94 36 Supply and fixing in repairs , 3 pole power contactor, 3 pole, type MK 1 complete all as specified and as directed. \n 1 Each
95 37 Supply and fixing in repairs, front mounting Add on Auxillary contact block type MNX A1 with 2 NO + 2 NC complete all as specified and as directed. \n 1 Each
96 38 Supply and fixing in repairs, front mounting Add on Auxillary contact block type MNX A2 with 1 NO + 1 NC complete all as specified and as directed. \n 1 Each
97 39 Supply and fixing in repairs, bi-metallic overload relay type MN 5 with single phase protection mounted on the contactor with current carrying capacity ranging from 30 - 50 A complete all as specified and as directed. \n 2 Each
98 40 Supply and fixing in repairs, bi-metallic overload relay type MN 2 with single phase protection mounted on the contactor with current carrying capacity ranging from 9-15 A complete all as specified and as directed.\n 2 Each
99 41 Supply and fixing in repairs, bi-metallic overload relay type MN 2 with single phase protection mounted on the contactor with current carrying capacity ranging from 20-33 A complete all as specified and as directed.\n 1 Each
100 42 Supply and fixing in repairs, bi-metallic overload relay type MK1 mounted on the contactor with current carrying capacity ranging from 0.6 - 18A complete all as specified and as directed.\n 2 Each
101 43 Supply and fixing in repairs electronic timer ST-100 type ranging from 3 - 10 sec/ 12-120 sec \n 2 Each
102 44 Servicing and maintaining pumping installation by tightening / replacing the gland rope of pump ,replacing rubber coupling, bushes and clearing the leakage of sluice valves, NRV's, aircock, pressure guage by tightening gland etc. complete at BMF Pump house comprising 4 Nos pump sets of capacity 30 HP -02 No & 40 HP - 02No complete all as specified and as directed. 1 Job
103 45 M & L for replacing rubber coupling of coupling set of any pumpset at different pump house complete all as specified and as directed. 4 Job
104 46 M & L for welding work for the broken pipe flanges / pump set base channel including necessary additional required material, checking/correcting the alignment of pumpset including removing & refixing, cleaning the dust, rust and necessary painting all as specified and directed 2 Job
105 47 M & L preparation of old painted surface of pump installation by removing all dirt, dust, grease, oil etc and painting complete with two coats of synthetic enamel paint of approved colour over a coat of red-oxide primer in Pump set - 02 Nos including their sluice valves, NRV and delivery / suction pipe line in BMF pump house all as specified & directed 1 Job
106 48 All as per serial item No. 47.00 here-in-before, but at Def Civ area pump house comprising 02 pump sets 1 Job
107 49 All as per serial item No. 47.00 here-in-before, but at NOFRA Pump house comprising 02 pump sets including valves-06, NRV-6 1 Job
108 50 All as per serial item No. 47.00 here-in-before,but at 24 Lt's pump house comprising 02 pump sets. 1 Job
109 51 All as per serial item No. 47.00 here-in-before, but at new Varunapuri Pump house comprising 01 pump sets including valves-03, NRV-3 1 Job
110 52 All as per serial item No. 47.00 here-in-before, but at Under Water Range area comprising 02 pump sets. 1 Job
111 53 All as per serial item No. 47.00 here-in-before, but at 203 Pump house comprising 05 pump sets. 1 Job
112 54 All as per serial item No. 47.00 here-in-before, but at Sewage Pump House comprising 02 pump sets including valves-03, NRV-3 1 Job
113 55 All as per serial item No. 47.00 here-in-before, but at New leading pump house area comprising 02 pump sets including valves-02, NRV-2 1 Job
114 56 All as per serial item No. 47.00 here-in-before, but at DAD complex pump house comprising 02 pump sets. 1 Job
115 57 M & L for bacteriological analysis of water sample at DIRECTORATE OF HEALTH SERVICES, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA complete all as specified and as directed. \n(NOTE : (a) The water sample should be carried in sterilised bottle/watercan which are to be collected from the SCIENTIFIC OFFICER, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA) by the contractor\nNote: Testing to be carried out every six months 20 Job
116 58 M & L for Chemical analysis of water sample at DIRECTORATE OF HEALTH SERVICES, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA complete all as specified and as directed. \n(NOTE : (a) The water sample should be carried in sterilised bottle/watercan which are to be collected from the SCIENTIFIC OFFICER, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA) by the contractor\nNote: Testing to be carried out every six months 20 Job
117 59 M&L Plate earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected using galvanised iron strip 25×4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel , including provision of GI pipe 40 mm bore medium grade of required length for protection of earthing lead, GI watering pipe 15mm bore medium grade with PGI sheet funnel and wire mesh , PCC 1:3:6, type B-1 chamber with 50 mm thick pre-cast RCC cover reinforced with 6 mm dia mild steel plain round bars spaced at 100 mm centres both ways with frame, filling the pit with charcoal & common salt surrounding the earth plate, including all necessary excavation & earth work in any type of soil all as shown in Electrical Plate No.3, connected to earthing test point including testing on completion complete all as specified & directed 8 Each Set
118 60 Checking of pumpset starter or motor for any fault installed at various locations under AGE E/M II of GE(NW) Vasco and carry out necessary repairs in order to keep in working condition\nNote:- \n(a) Repairs including material required will be measured and paid under relevant item if required. \n(b) Equipments/Testing meters required for detecting faults shall be provided by the contractor. 24 Job
119 61 Supply and fix in repairs to nozzle made out of brass of spraying assemblycomplete (As per sample) 16 Each
120 62 M&L for overhauling the fountain assembly comprising of cleaning the nozzles, changing the founatin PVC flexible pipe, painting the assembly, replacing the nozzles if required, rubber gasket, checking electrical connections for lights and pump & redoing with water proof tape etc including minor items required all as specified and diredted 2 Job
121 63 Repair to motor shaft / pump shaft including transporting to work shop, grinding, making slot for key if required, polishing and fixing back to position as earlier all as directed. 2 Job
122 64 M & L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in for foundation with grouting nut & bolt with necessary form work etc including dismantling pumpset with delivery and suction lines and making necessary alteration by fixing pipe and bend, refixing & realigning again after doing foundation at any Pump House complete all as specified and directed 1 Job
123 65 Supply, install, test and commissioning factory made indoor LT Panel board CPRI type tested, indoor type,weather/vermin proof, made out of 3 mm thick CRCA sheet in cubical pattern of suitable size, duly powder coated with front opening, floor mounted free standing type and compartmentalized construction, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply having 3 phase and neutral, 3 Nos aluminium bus bar of 150 Amps for 3 phase and neutral bus bar of 100 amps capacity duly insulated with heat shrinkable colour coated sleeve complete and painted wtih powder coating 7 tank process with locking arrangement complete with IP 52 class protection and mounted on base angle iron 50x50x5mm, grouted with PCC (1:3:6) foundation / bedding up to height of 30 cm above groung level and the job includes dismantling of existing LT panel carefully without damaging incoming cables and connecting to proposed pumpset all as specified and directed at 203 pump house. the panel shall comprises of following items accessories: 1 JOB
124 65.01 (a) MCCB TPN 100 Amps 4 pole with micro processor release of 50 KA breaking capacity - 01 No (Incoming) and earth fault relay\n(b) MCCB TP (motor back up protection type ) of 50 KA breaking capacity of 32Amps- 01 No, 50amps-01No, 63amps - 01 No (Outgoing)\n(c) Voltmeter (0-500V) -01 No, pf meter - 01 No & energy meter with CT- 01 No all digital type for incoming main supply with all connecting accessoires like start & stop push Botton, indicating lights for RYB, ON & trip etc (LED type)\n(d) Ammeter digital type (0-100Amps) - 03 Nos with CTs and selector switch\n(e) Power factor improvement capacitor - 6 KVAr with 20 Amps MCB 3 pole 10 kA\n(f) Fully automatic Star - Delta Starter 10HP - 02 Nos, 7.5HP - 02 Nos.\n(g) Single phase preventor - 03 No\n(h) Internal All links with copper conductor of adequate capacity
125 66 S & F in repairs Framed work such as ladders, walk ways, railings & hand rail, shed and frame work for pump channel water supply installation and similar work including cutting tops to shape, drilling holes, notching for wire etc embedded in concrete / masonary complete duly painted with two coats of primier and one coat on synthetic enamel paint, drilling, bolting or reveting con-forming to Fe.290.Gde-E-165 including fixing it on required surface with necessary cement and welding work complete all as specified. 100 Kg