}

Request For Proposal For Overall Maintenances And Operation Of Non-It Equipments Installed At Datacenter Rsdc P-1,2 And 3, Jaipur-Rajasthan

Raj Comp has published Request For Proposal For Overall Maintenances And Operation Of Non-It Equipments Installed At Datacenter Rsdc P-1,2 And 3, Jaipur. Submission Date for this Tender is 28-01-2021. Distribution Board Tenders in Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

26553912
Request For Proposal For Overall Maintenances And Operation Of Non-It Equipments Installed At Datacenter Rsdc P-1,2 And 3, Jaipur
Open Tender
Indian
Rajasthan
28-01-2021

Tender Details

Request For Proposal For Overall Maintenances And Operation Of Non-It Equipments Installed At Datacenter Rsdc P-1, 2 And 3, Jaipur-Diesel Generator ( Make: Kriloshkar-Koel ) , Ups System ( Make: Emerson ) , Battery Bank , Ups System ( For Other Load ) ( Make: Emerson ) , Battery Bank , Dg Amf Synchronization Cum Auto Load Management Panel , Main Lt Panel , Apfc Panel , Pac Panel , Lighting Db 11 Double Door Distribution Boards Including Surge Arrester For Each Phase ( For Light Dbs Only ) : - 12 Way Tpn 12 Incomer - 63 Amps Tpn -1 Nos 13 Outgoing - 36 Nos Sp Mcb 14 Double Door Distribution Boards Including Surge Arrester For Each Phase ( For Light Dbs Only ) : - 12 Way Tpn Outgoing - 35 Nos Sp Mcb 15 Incomer - 63 Amps Tpn -1 Nos 16 Outgoing - 36 Nos Sp Mcb 17 Distribution Boards Including Surge Arrester For Each Phase ( For Light Dbs Only ) :- 12 Way Tpn Incomer - 63 Amps Tpn - Outgoing - 36 Nos Sp Mcb 18 Ups Output Panel / Pdu ( For Rack Loads ) As Installed At Site Ups Output Panel, Including Following: Incomer: 400 Amps 36 Ka 4Pole Microprocessor Based Mccb 1 No. Outgoing: 19 Cabling Upkeep And Maintenance Of 1100 Volt Grade, Pvc Insulated And Armored, Copper Or Aluminum Conductor Cables Of The Following Sizes As Installed At Site: For Item No 20, 21, 22, 23, 24, 25, 26, 27 20 4 Core X 4 Sq. Mm. Cu Armoured Cable 21 4 Core X 6 Sq.Mm. Cu. Armoured 22 4 Core X 16 Sq.Mm. Cu. Armoured 23 4 Core X 25 Sq.Mm. Cu. Armoured 24 1 Core X 300 Sq.Mm. Cu. Armoured Cables 25 3.5 Core X 400 Sq.Mm. Al. Armoured Cables 26 3.5 Core X 150 Sq.Mm. Al. Armored Cables 27 3.5 Core X 120 Sq.Mm. Al. Armored Cables 28 Earthing 29 Upkeep And Maintenance Of 3.0 Meter Long Gel Type Earthling With Copper Electrode As Installed At Site. 30 Upkeep And Maintenance Of 600 X 600 X 3 Mm Copper Plate Type Earthing As Installed At Site. 31 Lighting & Power Wiring Upkeep And Maintenance Of Standard Wiring Electrical Points Including Wires, Sockets / Switches ( 6 Amps, 16 Amps & 32 Amps ) Etc As Installed At Site: 32 Lighting Fixtures ( Make: Philips ) Upkeep And Maintenance Of The Following Fixtures Wired With High Frequency Ballasts, Lamp Holders And Complete With Lamps / Led Fixtures As Installed At Site: 33 1 X 28 Watts Slimlite Fixtures With Electronic Ballast / Led Fixtures 34 2 Xpl -L 36 Watts Decorative Panel / Led Lights White Direct Luminaries For Modular Ceiling. 35 4X18 Watts Decorative Recessed Mounting Luminaries. 36 2 X Pl - C 18 Watts Recessed Mounting Down Light Luminaries With Recessed Glass Raindrops 37 2 X Pl - C 18 Watts Recessed Ceiling Mounting Light Luminaries With Recessed Glass Raindrops 38 2 Xpl -L 36 Watts Decorative Panel Lights White Direct Luminaries For Modular Ceiling. 39 1 X 28 Watts Recessed Mounting Down Light Luminaries With Recessed Glass Raindrops. 40 2 X 36 Watts Decorative Panel Down Lights White Direct Luminaries. 41 35 Wattsp / F Recessed Type 2X2 Sized Standard Quality Led Lighting Fixtures 42 Maintenance Of Pac Auto Changeover Switches Per The Specs 43 Maintenance Of Automatic Fuel Level Monitoring With Flow Meter 44 Air Conditioning System 45 Precision Packaged Units ( Make: Emerson ) As Installed At Site With Indoor And Outdoor Units 20 Tr ( Min ) Sensible Capacity Precision Air - Conditioning Unit For Datacenter As Installed At Site. 46 Air Grills With Volume Control Damper 47 Return Air Motorized Damper 48 Comfort Cooling System ( Make: Blue Star ) A ) Air Cool Duct Able Type Ac Units Comprising Ofb1 X Indoor Unit, 8.46 Tr Nominal Capacity Complete As Installed At Site. 49 Air Cooled Cassette Type Ac Units ( Make: Blue Star ) Comprising Of: 1 X Indoor Unit, 3 Tr Nominal Capacity Complete & As Installed At Site. 50 Access Control System 51 Access Control Unit ( Rtu ) , ( Honeywell ) 52 Magnetic Lock Single 600 Lbs, ( Bell ) 53 Access Reader, ( Hid ) 54 Exit Push Switch 55 Emergency Door Realease 56 Tema Server, ( Honeywell ) 57 Biometric Reader, ( Bioscrypt-4G ) 58 Rs 232 To 485 Converter, ( Q Com ) 59 Tema Power Supply 60 Rtu Relay 61 Relay Power Supply 24V 62 Rtu Power Supply 12V 63 Dps Switch 64 Magnetic Lock Double 600 Lbs, ( Bell ) 65 U Shape Bracket For Glass Door, ( Bell ) 66 Tema Server Power Supply, ( Honeywell ) 67 Bio-Metric Work Station, ( Secure-Admin ) 68 Cctv System 69 Dvr, ( Honeywell ) 70 Ptz Camera, ( Samsung ) 71 Fixed Dome Camera, ( Honeywell-22, Samsung-1 ) 72 Hdd ( 1 Tb Each ) , ( Seagate ) 73 Dvr Monitor, ( Lg ) 74 Camera Power Supply 75 Dvr Remote, ( Lg ) 76 Web Application For Cctv, ( Control Center ) 77 Rr System 78 Rodiant Panel, ( Maser ) 79 Stand With Bracket, ( Honesty ) 80 Rodiant Satelite , ( Maser ) 81 Wld System 82 Wld Panel 4 Zone, ( Jay Fire ) 83 Wld Hooter, ( Honeywell ) 84 Fire Alarm System 85 Fire Alarm Panel, ( Honeywell ) 86 Loop Power Module 87 Loop Card Driver 88 485 Comm. Card 89 Network Module, ( Honeywell ) 90 Repeter Panel, ( Honeywell ) 91 Photo Electric Smoke Detector With Base, ( Honeywell ) 92 Manual Call Point 93 Hooter Cum Strobe 94 Control Relay Module 95 Monitor Relay Module 96 Isolater Relay Module 97 Battery, ( Amco-Best ) 98 Response Indicator, ( Honeywell ) 99 Panic War, ( Dafikas ) 100 Vesda 101 Vesda 4 Zone Panel, ( Xtralis ) 102 Power Supply 103 Display Module 104 P.A System 105 Rack For Pa & Dvr 106 Ceiling Mount Speaker, Bosch 107 Main Controller, Bosch 108 Amplifier 200 W, Bosch 109 Call Station, Bosch 110 Fm 200 System 111 Fm-200 Cylinder With Ass., Kidde 112 Gas Release Panel, Honeywell 113 Abort Switch With Moudle, Adwards 114 Manual Switch With Moudle, Super Fire 115 Service Dis-Connect Switch With Moudle, Adward 116 Fm 200 Nozzle , Kidde 117 Pressure Transmeter 118 Power Supply 119 2 Kg Naf Piv Fire Extinguisher, ( Safex ) 120 5 Kg Abc Type Piv Fire Extinguisher, ( Safex ) 121 Co2 4.5 Kg Portable Fire Extinguisher, ( Safex ) 122 Bms 123 Ddc Panel, ( Rittal ) 124 Ipc Controller, ( Honeywell ) 125 Expio Controller ( Honeywell ) 126 Temp Cum Rh Sensor ( Honeywell ) 127 485 To Lan Convertor, ( San-Telequid ) 128 232 To 485 Convertor, ( Q Com ) 129 Tank Level Transmiter, ( Techtrol ) 130 Ebi Server With Monitor, ( Dell ) 131 Plc Convertor , ( Q Com ) 132 Bms 133 Projector Pt-F200nt Xga, ( Panasonic ) 1 Air Conditioners ( Daikin Make ) As Installed At Site 2 Ceiling Mounted Cassette Type Acs-1.06 Tr 3 Ceiling Mounted Cassette Type Acs-1.32 Tr 4 Ceiling Mounted Cassette Type Acs-1.65 Tr 5 Ceiling Mounted Cassette Type Acs-2.08 Tr 6 Ceiling Mounted Cassette Type Acs-2.65 Tr 7 Ceiling Mounted Cassette Type Acs-3.3 Tr 8 Ceiling Mounted Cassette Type Acs-4.13 Tr 9 Wall Mounted Cassette Type Acs-0.66 Tr 10 Wall Mounted Cassette Type Acs-1.06Tr 11 Wall Mounted Cassette Type Acs-2.08 Tr 12 Wall Mounted Cassette Type Acs-0.83 Tr 13 Precision Packaged Units ( Emerson Make ) As Installed At Site. 20 Tr ( Min ) Sensible Capacity Precision Air - Conditioning Unit For Datacenter. 14 Ups ( Emerson Make ) For Item No 14, 15 As Installed At Site. 15 20 Kva 3 Phase Ups 16 80 Kva 3 Phase Ups 17 Light Fittings &Luminiar ( Bajaj Make ) For Item No 18, 19, 20, 21, 22 As Installed At Site. 18 2X36 Watt Cfl / Led Light Panel ( Recess ) 19 2X18 Watt Cfl / Led Light Panel ( Recess & Surface ) 20 1200 Mm Sweep 5 Star Ceiling Fan 21 400Mm Sweep Wall Fan 22 1X28 Watt T-5 Light 23 Fire Detection & Sprinkler System ( Siemens Make ) For Item No 24, 25, 26, 27, 28, 29 As Installed At Site. 24 100Mm Gun Metal Butterfly Valve 25 63 Mm Dia 15 Meter Long Rrl Pipe 26 First Aid Hose Reel & Drums 27 1 Loop Microprocessor Based Addressable Analog Fire Alarm Control Panel. 28 Mcp 29 Hooter 30 Fire Supression System For Server Farm Area For Item No 31, 32, 33, 34, 35, 36& As Installed At Site. 31 80 Liters Seamless Novec Cylinders 32 Manual Release Unit & Abort 33 Sinorix1230 34 Discharge Nozzles 35 Optical Smoke Detector 36 Gas Release Panel 37 Dg Sets ( Cummins-Sudhir Make ) For Item No 38 & 39 As Installed At Site. 38 200 Kva, 415 Volt, 50 Hz, 3 Phase Ac Silent Dg Set 39 125 Kva, 415 Volt, 50 Hz, 3 Phase Ac Silent Dg Set 40 Lt Panels For Item No 41 & As Installed At Site. 41 Comprising Of Following: 630 Amp, Fp, 50 Ka Mccb-1 No ) , ( 300 Amp, Fp, 25 Ka Mccb-1 No ) , 300 A, Fp, Contactor-1 No ) , ( 400A Tp 35 Ka Mccb-1 No ) , ( 250 A Tp 25 Ka Mccb-1 No ) , ( 160 A Tp 16 Ka Mccb-1 No ) ( 63 A, Fp, 10 Ka, C Curve Mcb-1 No ) , 63A, Fp, 10 Ka, C Curve Mcb-4 Nos, Apfc Section Capacitor Bank-100 Kvar, Amf Section, Protection Section, Meeting Section. 1 Civil Work 2 Fired Rated Door With Lock And Heavy Duty Door Closer. 3 Wooden Door Single And Double Leaf For Bms And Storage Rooms, Noc And Call Centre Area. 4 Glass Door With 12 Mm Toughened Glass, Floor Spring, Arrangement For Access Control, Handle, Lock Etc. 5 13Mm Thk Nitrile Rubber Insulation With Alumium Foil Use Under The False Flooring & True Ceiling With Adhesive And Pvc Jointing Tapes Wherever Necessary As Per Standard Installation ( Server Room Only ) 6 Productivity Work Chair ( Exclusing Chairs For Call Centre ) 7 Long Back Executive Chair, Visiting Chair 8 Reception Desk With Board Trays, Cpu Trollys, Three Drawer , Etc. 9 Vertical Blinds, Aluminum Perforated, Of Approved Shade To Be Used For Covering The Glass Wall And Windows Excluding Noc & Development Center. 10 Sofa Set With 3 + 2 Seating Arrangement Along With Tea Table 11 Wooden Door With Louvers Covering Fire Suppression Cylinder 12 Fire Safe ( 300 Lt ) Godrej For Media / Backup Tapes 13 Ramp & Steps 14 Fire Rated Glass Window With Powder Coated Aluminium Frame For Data Centre Area 15 H.T. Works: 16 Cables And Terminations 1 ( 3C X 240 Sq.Mm ) , 11Kv Cross Linked Polyethylene ( Xlpe ) Insulated Aluminium Conductor Steel Armoured Cables Buried Underground. 17 1 ( 3C X 240 Sq.Mm ) , 11Kv Cross Linked Polyethylene ( Xlpe ) Insulated Aluminium Conductor Cable Gland, Outdoor Type Cable Sealing Kits, Insulation Tape, 18 Ht Metering Cubicle ( Outdoor ) 19 11Kv Ht Metering Cubicle Including All Cts, Pts Etc. Suitable For Cable Entry On Both Sides. 20 Ht Panel With 1 Incomer And 2 Outgoing Of 630A, 11Kv, 20Ka Ht Vcb Breaker ( Edo Type ) With Spare Out Going Breaker 21 Battery Charger : Battery Charger With One Set Of 24V Dc 100Ah Station Batteries With Suitable Battery Charge Inclusive Of 6 Way Spn Db 22 3 Phase, 50 Hz, Copper Wound, Oil Immersed, Core Type Transformer Of 1000 Kva Rating , Onan ( Oil Natural Air Forced ) Oltc With Voltage Ratio 11 / .433 Kv, Connection Hv / Lv: Delta / Star, . The Transformer Should Have One Side Ht Cable Termination And Secondary Provision For Bus Bar For Terminating Bus Duct. 23 Transformer Output Breaker Of 1250 Amp Breaker Panel ( Out Door Type ) 24 Spreading Of 40 Mm Metal In Outdoor H.T.Yard - Upto 100 Mm - Thick Layer 25 Fire Buckets With Stand Filled With Fine River Sand. 2 Buckets With Round Botton, Red Painted Duly Marked As Fire 26 Lt Panels 27 415 Volts, 3Phase 50Hz Panel As Per Specification 415V Switch Boards As Per The Specifications And Schematic Drawing Complete As Required. Dg Sync Cum Amf Panel 28 415 Volts, 3Phase 50Hz Panel As Per Specification 415V Switch Boards As Per The Specifications And Schematic Drawing Complete As Required. Datacenter Main Panel - 1 And 2 As Per Rfp Schematic 29 Supply, Loading, Unloading, Erection, Testing & Commissioning Of 415 Volts, 3Phase 50Hz Panel As Per Specification 415V Switch Boards As Per The Specifications And Schematic Drawing Complete As Required. 200Kva / Kw Galvonic Isolation Transformer 30 415 Volts, 3Phase 50Hz Panel As Per Specification 415V Switch Boards As Per The Specifications And Schematic Drawing Complete As Required. 40 Kva Ups Output Panel 31 415 Volts, 3Phase 50Hz Panel As Per Specification 415V Switch Boards As Per The Specifications And Schematic Drawing Complete As Required. Pac Panel 32 415 Volts, 3Phase 50Hz Panel As Per Specification 415V Switch Boards As Per The Specifications And Schematic Drawing Complete As Required. Cac Panel -01 33 415 Volts, 3Phase 50Hz Panel As Per Specification 415V Switch Boards As Per The Specifications And Schematic Drawing Complete As Required. Cac Panel -02 34 415 Volts, 3Phase 50Hz Panel As Per Specification 415V Switch Boards As Per The Specifications And Schematic Drawing Complete As Required. Pdu 1A / 2A And 1B / 2B 35 415 Volts, 3Phase 50Hz Panel As Per Specification 415V Switch Boards As Per The Specifications And Schematic Drawing Complete As Required. 380 Kvar Apfcr Bank 36 32A, Dp, Mcb Isolator Wall Mounted Type With Suitable Enclosure And Required Accessories For Comfort Ac As Per Rfp Schematic 37 80Amp Rating Automatic Changeover Panel 38 Bus Duct For Transformer-01 & 02 Up To The Data Centre Lt Panel-01 & 02 Respectively. Dg Sync Panel To The Dc Lt Panel-01 And 02 1250A Aluminium Ip65 Straight Feeder 39 Bus Duct For Dg-01, 02 & 03 Up To The Dc Sync Panel-01 & 02 Respectively 800A Aluminium Ip65 Straight Feeder 40 Track Busways Overhead Power Distribution In Data Centers And Labs With Spring Pressure Copper Conductors In Continuous Pvc Insulation, Extruded Aluminum Housing, Light Weight To Install With Hitech Rods And Anchor Fastners. Housing Will Have Continuous Bottom Access To Facilitate Insertion Of Outlet Box Any Where Along The Length. Outlet Boxes Are Suitable To Reverse To Face Either Cold Aisle Or Hot Aisle Busway Are For Indoor Use, Finger Proof To Ul. 100Amp Track Busway, 100%N, Busway Section, 3 Mtr 200% Note: Proposed Busduct Shall Capable To Plun The Tapp-Off Box At Any Point Of Busway. 41 Providing The End Terminations With Copper Lugs For All The Above Cables With Double Compression Brass Cable Glands, Taping, Crimping, Gland And Armour Earthing, Complete Electrical System Of Dc 42 Power Wiring Circuits ( Raw Power And Ups Power ) 43 Internal Light Fixtures 44 Complete Dc Excluding Noc, Cc Area 45 Motion Sensors For Multiple Areas For Automatic Switching The Lighs On An Off 46 Steel Items 47 Rubber Mats, First Aid Box, Shock Treatment Charts And Other Sundry Items ( Sizes / Capacities To Be Got Approved ) . 48 Precision Air Conditioning Units 49 Air Cooled Condenser With Fan Speed Controller Inside Design Condition Server Room - 22 + / - 1 Deg. C & Relative Humidity : 50% Rh + / - 5% A. Nominal Capacity 26 Tr - E. Bms Interface For Integration With Necessary Network Integration Card 50 Supply Air Floor Grilles With Damper , 600Mm X 600Mm 51 Cac / Vrv 52 Outdoor Units: Multi-Vrf Units Complete With 100% Inverter Driven Scroll Compressor, 22 Hp ( Cooling-Only ) , ( 2X5 ) 53 Indoor Comfort Ac Units:4-Way Cassatte Unit ( 2Tr ) 54 Indoor Comfort Ac Units: 4-Way Cassatte Unit ( 2.5Tr ) 55 Indoor Comfort Ac Units: 4-Way Cassatte Unit ( 3Tr ) 56 Indoor Comfort Ac Units: 4-Way Cassatte Unit ( 4Tr ) 57 Indoor Comfort Ac Units: Msp Ductable ( 4.6Tr ) 58 Indoor Comfort Ac Units: Hi-Wall ( 1Tr ) 59 Indoor Comfort Ac Units: Wireless Remote 60 Wired Remote 61 Centralize Remote ( Touch Type ) 62 32A, 1 Ph, Ip Metered Pdu ( Strip Level Monitoring ) Rack Pdu, Metered, Zero U, 32A, 230V, ( 20 ) C13 & ( 4 ) C19 63 32A, 3 Ph, Ip Metered Pdu ( Strip Level Monitoring ) Rack Pdu, Metered, Zero U, 32A, 230V, Minimum Of 6 Nos C13 & 6 Nos C19 64 Cold Aisle Containment System_Row -1 ( Sr1 To Sr72+ 10Nr ) Includes:A. Start & End Roof Element 800X1200 Stable Roof Elements In A Composite Metal With A High Level Of Light Permeability ) B. Center Roof Element 600X1200 ( Stable Roof Elements In A Composite Metal With A High Level Of Light Permeability ) C. Door Element 1200W X 2100H ( Slimline Door Element With Viewing Window, Sliding Door ) 65 Ups 66 Ups Of 200 Kw, 3 Phase In, 3 Phase Out, 415 V, Modular Hotswappable Design Consisting Capable To Parrallel Up To Minimum 400Kw Of It Load. 67 Ups Of 40 Kw, 3 Phase In, 3 Phase Out, 415 V, Modular Hotswappable, Bms System Emergency Light And Non_It Load 68 Battery Ms Stand, Inter Cell Connection, Battery To Ups Main Cable For 200 / 40 Kva Ups 69 Dg Set 70 500 Kva ( + / - 5% ) Dg Set And ( Cable / Bus Duct ) With Extended Alternator Terminal With Bus Bars Including Control Switchgear Etc. 71 Exhaust Of Dg Sets Including Providing Suitable Self Supporting Arrangement 72 Control Cabling 73 Copper Earthing For Dg Set 74 Intelligent Addressable Fire Alarm Control Panel With 1 Loop Card And Battery Backup Of 24 Hrs In Normal Condition And 30 Min In Alarm Condition With Necessary Accessories 75 Multisensor Detector With Accessories 76 Response Indicator With Accessories 77 Fault Isolators Module With Accessories 78 Addressable Control Relay Modules. ( For Grp, Acs, Hooters, Pas ) 79 Addressable Manual Call Points With Accessories 80 Addressable Monitor Modules With Accessories ( Monitoring Vesda ) 81 Sounders With Strobes With Accessories As Per Technical Specification 82 Ceasefire 4 Kg Fire Extinguisher Clean Agent , 83 Public Address System. 84 Public Address System With 6 Zone Micro- Processor Based Based Selection Panel Complete With Interface Fire For Fire Tone Generator And Paging Announcement System & Gooseneck Microphone With Rack To Mount All Controllers. 85 6W Ceiling Mount Speaker 86 Volume Control ( For Dc Manager Cabins ) 87 Access Control System. 88 Access Control System Tcp / Ip Enabled 2 Reader Access Door Controller With Power Supply And Housing 89 Finger Print Biometric Reader With Smart Card Reader With Accessories 90 Smart Card Reader With Accessories 91 Smart Cards 92 Electromagnetic Lock With Inbuilt Magnetic Contact & Power Supply With Accessories 93 Emergency Break Glass Unit With Accessories 94 Access Management Software With Time & Attendance Software 95 Pc For Access Control Software 96 Card Printer With Accessories 97 Cctv Surveillance System. 98 Ul Listed 1 / 3 Cmos, 800X 600 Resolution, 3~8Mm Varifocal Lens, Minimum Of 0.5 Lux @ 40 Ire, Poe Enabled Indoor Dome Camera With Accessories 99 Ul Listed 1 / 3 Cmos, 1080X 720 Resolution, 3~8Mm Varifocal Lens, Minimum Of 0.5 Lux @ 40 Ire, Ptz Camera With Accessories 100 Network Video Recorder With Backup Of 30 Days ( Recording: 4 Cif Resolution, 15Fps, 30Days Online ) With Camera License & 2 Nos. Of Client Licenses 101 Pc For Monitoring Camera 102 42 Colour Led Monitor As Per Technical Specification 103 Aspiration Based Detection System 104 Aspiration Detection Panel For Server Room 105 Power Supply Unit With Accessories As Per Technical Specification 106 Electronic Hooter 107 Fire Suppression System 108 120 Ltr Seamless Cylinder With Valve 109 Master Cylinder Kit With Following Items - Pr. Guage + Low Pr. Supervisory Switch - Electromagnetic Actuator - Manual Actuator - Pneumatic Actuator - Flexible Discharge Hose - Flexible Actuation Hose 110 End Slave Cylinder Accessories As Per Technical Specification Pressure Operated Control Head Actuation Hose, 30 Discharge Hose, 2 X 31 111 Gas Discharge Nozzles 112 Gas Release Panel 113 Abort Switch 114 Release Switch 115 Hooter With Power Supply 116 Rodent Repellent System 117 Rodent Repellent System With Stands 118 Water Leak Detection System 119 Water Leak Detection Panel With Modbus Connectivity 120 Water Leak Detection Cable Sensor – 10 Mtrs 121 Water Leak Detection Cable Sensor – 25 Mtrs 122 Electronic Hooter 123 Workstation Operator Machine: Intel I3 Processor 3Rd Generation, 500Gb Hdd, , 4Gb Ram, 52X Cd Rw , 21 Colour Monitor, Usb Mouse, 2 Serial, 1 Parallel Port & Windows Operating System 124 Building Management System Software 125 Colour Laser Printer 126 Ibms 127 32 Bit Ddc Controller Above Along With System Integration Units, Powder Coated Cabinets As Per Standards For Electrical Panels And All Internal Terminations And Cabling To Monitor Temperature Humidity In Server Room Ddc For Intergartion Of Variours Physical Security Substems Mentioned And Temperature And Humidity Monitoring As Per Io Summary Pac Units Integration ( 30 Points / Unit ) Ups Units Integration ( 30 Points / Unit ) Fire Alarm System Water Leak Detection System 128 Temperature & Humidity Sensor 129 Tv Screens For Manager Cabins With Wall Mounted 32 Led Tv Screen For Dc Manager Cabin-01 And - 02 130 Monitor Screens For Manager Cabin-03: Wall Mounted 42 Led Monitor Screen For Dc Manager Cabin- 03 With Required Length Of Vga / Hdmi Cable 131 Dcim 132 Data Center Infrastructure Management Software Per Rack Perpetual License For 80 Racks And As Per Rfp Specificationdcim ( Data Center Infrastructure Management ) Application For Power, Cooling, Space, Environment, Safety , Security Infrastructure Devices Monitoring & Management To Meet Rfp Compliance.Non It Devices: ( Device To Be Monitored & Managed, Rack, Pdu, Energy Meters, Ups Pac, Dg Set, Fss, Fda, Wld, Rrd ) It Devices - Server:Dcim - It Infrastructure Monitoring Application Module: 100 It Devicesit Devices -Storage Dcim - It Infrastructure Monitoring Application Module- 3 Nos It Devicesit Devices - Network Security Devices ( 50 Nos Of Network And Security Devices ) Dcim - Network Infrastructure Monitoring Application Modulet&H Sensors- 26 Nos.Temperature & Humidity Sensor ( Rs485, Modbus ) Minimum Capability - A. Should Have Digital Dispay, B. 2 Rs485 Communication Port, C. Temperature Measurement Accuracy +3 Or -3 Degree, D. Humidity Measurement Accuracy +5 % Or -5 %, E. Should Have Local Alarm For Identification. Controller-2 Nos.Minimum Capability - 1. Should Be Capable Monitor Up To 20 Temperature & Humidity Sensors, Up To 16 Intelligent Devices ( Snmp & Rs485 Modbus Enable, 2. Built In Webpage Of Its Own For Monitoring 3. Local Storage Of Data Upto 7 Days 4. Should Be Capable Of Sending Email Notification Directly, 5. Should Be Capable To Share Data With Third Party Application Over Modbus-Ip Or Bacnet-Ip Or Snmp Polling & Trap. 133 Lan Work: Cat 6A Cabling Bom 134 Lan Work: Cat 6A Cabling Bom ( Complete Dc Excluding Noc & Development Center ) 1 Overall Maintenance Of Items Installed In Rsdc P-1 As Per Items Details Enclosed In Annexure-1 Of Rfp. The Maintenance Is To Be Carried Out As Per Maintenance Schedule Of Original Oem. The Bidders Should Have Back To Back To Maintenance Contract For 24 X 7 With Original Oem Of Items Installed As Per Details Given In Rfp. 2 Overall Maintenance Of Items Installed In Rsdc P-3 As Per Items Details Enclosed In Annexure-1 Of Rfp. The Maintenance Is To Be Carried Out As Per Maintenance Schedule Of Original Oem. The Bidders Should Have Back To Back To Maintenance Contract For 24 X 7 With Original Oem Of Items Installed As Per Details Given In Rfp. 3 Overall Operation Of Systems Installed In Rsdc P-1 & P-3 As Per Items Details Enclosed In Annexure-1 And As Per Number Of Persons / Shifts Details, Service Level Agreements ( Sla ) Given In Rfp. The Bidder Has To Deploy The Manpower At Site At Both Data Center Premises As Per Details Given In Rfp. 4 Overall Maintenance Of Items Installed In Rsdc P-2 As Per Items Details Enclosed In Annexure-2 Of Rfp. The Maintenance Is To Be Carried Out As Per Maintenance Schedule Of Original Oem. The Bidders Should Have Back To Back To Maintenance Contract For 24 X 7 With Original Oem Of Items Installed As Per Details Given In Rfp. 5 Overall Operation Of Systems Installed In Rsdc P-2 As Per Items Details Enclosed In Annexure-2 And As Per Number Of Persons / Shifts Details, Service Level Agreements ( Sla ) Given In Rfp. The Bidder Has To Deploy The Manpower At Site At Both Data Center Premises As Per Details Given In Rfp.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 5 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail