Military Engineer Services-MES has published Repairs Maintenance Of Sewage Line , Septic Tank , Soak Well And Allied Works In Zone-D1 And Zone-D2 Of Age Br-Ii Under Ge ( East ) Lucknow. Submission Date for this Tender is 02-02-2021. Water Wells Tenders in Lucknow Cantt Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 26-Jan-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-02-2021 |
Name of Work: REPAIRS MAINT OF SEWAGE LINE ,SEPTIC TANK, SOAK WELL AND ALLIED WORKS IN ZONE-D1 AND ZONE-D2 OF AGE BR-II UNDER GE (EAST) LUCKNOW. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of cement concrete (unreinforced) in ground floor and paving not exc 15cm thick above or below ground level complete all as specified and directed. | 5 | Cum | |
2 | 2 | M&L for 50mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floor surface finished even and smooth without using extra cement complete all as specified and directed. | 50 | Sqm | |
3 | 3 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. | 15 | Cum | |
4 | 4 | M&L brick work with fly ash bricks old size, straight or curved on plan exc. 6.0M mean radius, built in cement mortar 1:6 complete all as specified and directed. | 12 | Cum | |
5 | 5 | All as per item no 4 above but except bricks. (Bricks recd from demolition) complete all as specified and directed. | 3 | Cum | |
6 | 6 | M&L for brick work with fly ash bricks, old size, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed. | 15 | Sqm | |
7 | 7 | Taking down of cement plaster in any description on brick or stone wall etc, incl racking out joints hacking for key scrubbing down with water etc complete all as specified and directed. | 150 | Sqm | |
8 | 8 | M&L for rendering10mm thick on fair faces of brick work or on concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed. | 150 | Sqm | |
9 | 9 | M&L for rendering 15mm thick on otherthan fair faces of brick work or on concrete surfaces in CM 1:4 with WPC @ 3% by weight of cementfinished even and smooth without using extra cement complete all as specified and directed. | 100 | Sqm | |
10 | 10 | Supply only integral waterproofing compound of approved make complete all as specified and directed. | 30 | Kg | |
11 | 11 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. | 4 | Cum | |
12 | 12 | M&L for precast RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slab, shelves and similar articles set in CM 1:4 complete all as specified and directed. Note:- Reinforcement shall be measured & paid separately | 3.5 | Cum | |
13 | 13 | M&L for cement concrete 1:2:4, type B-2, using 40 mm graded stone aggregate in flooring even and smooth without using extra cement complete all as specified and directed. | 2.7 | Cum | |
14 | 14 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in lintel up to 1.5m clear span, cills, steps, bands, coping including weathering, slightly rounded or champhered, angle and throating as directed and other similar work all as specified including necessary form work complete all as specified and directed. | 2 | Cum | |
15 | 15 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar works; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed. | 20 | Sqm | |
16 | 16 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors & roofs not exc 20cm wide & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work exc 10cm but exc 20cm wide complete all as specified and directed | 15 | RM | |
17 | 17 | M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. | 250 | Kg | |
18 | 18 | All as per item no 17 above but 6mm to 8mm dia. | 100 | Kg | |
19 | 19 | All as per item no 17 above but 5mm dia and over upto and including 10 mm dia in stirrups,apacers and binders. | 10 | Kg | |
20 | 20 | M&L for RCC 1:1.5:3 (nominal mix) using 20 mm graded stone agg as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. | 2.5 | Cum | |
21 | 21 | M&L PCC 1:3:6 type C2 in surface channel or drains including necessary form works , stops ,moulds etc complete all as specified and directed.\n | 2 | Cum | |
22 | 22 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including necessary forms mould mitred /stopped ends etc complete all as specified and directed.\n | 15 | RM | |
23 | 23 | Demolition and breaking up drain pipes (SGSW, AC or RCC) of 150mm bore sizes, set in cement mortar complete all as specified and directed. | 140 | RM | |
24 | 24 | M&L for salt glazed stone ware drain pipe grade A 150 mm internal dia (ISI marked) laid in trenches and jointed in cement mortar (1:1) and tested complete all as specified and directed. | 140 | RM | |
25 | 25 | M&L for cement concrete type C2 (1:3:6) with 100 mm thick bedding to drain pipes of 150 bore sizes including packing under and hunching against the sides of pipes after they are laid and tasted; in cement concrete complete all as specified and directed. | 140 | RM | |
26 | 26 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier hole etc and getting out in soft/loose soil complete all as specified and directed. | 30 | Cum | |
27 | 27 | Returning filling in trenches including spreading leveling, watering and well ramming in layer not exc 25 cm thick complete all as specified and directed. | 5 | Cum | |
28 | 28 | Removing of excavated materials to a distance 1.5 km and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. | 25 | Cum | |
29 | 29 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching complete all as specified and directed. | 4 | Each | |
30 | 30 | S&F of 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall incl MS holding clamps including taking down existing pipe complete all as specified and directed. | 100 | RM | |
31 | 31 | S&F of 75 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall incl MS holding clamps including taking down existing pipe complete all as specified and directed. | 20 | RM | |
32 | 32 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc including taking down existing pipe complete all as specified and directed. | 20 | RM | |
33 | 33 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc including taking down existing pipe complete all as specified and directed. | 5 | RM | |
34 | 34 | S&F, 110mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed. | 5 | Each | |
35 | 35 | S&F, 75mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed. | 5 | Each | |
36 | 36 | S&F in repairs vitreous china squatting pan "Orissa" pattern size 580mmx440mm white with integral foot rests including connection to trap, and to flushing pipe, anti syphonage pipe, etc complete making good to floors and complete all as specified and directed. \n | 10 | Each | |
37 | 37 | S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) including connection to drain or out going pipe and flush pipe anti syphonage pipe etc complete all as specified and directed.\n | 5 | Each | |
38 | 38 | S&F in repair for plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.\n | 10 | Each | |
39 | 39 | S&F as in repair PVC valve less, syphonic action type flushing cistern 10 lit capacity, low level white with inlet, ball valve , float and handle including brackets and flush pipe fixed etc complete all as specified and directed.\n | 10 | Each | |
40 | 40 | S&F in repair vitreous china urina, bowl type (back or corner wall type) size of 465x355x265mm white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinalto plugs with and including 60 mm long brass screws, pointing around urinal back in cement, complete all as specified and directed. | 5 | Each | |
41 | 41 | S&F steel water tubes medium grade, galvanised with all fittings 15mm bore fixed complete to concilled in walls and ceiling or laid in floors including taking up or down steel tubing and connections, 15mm bore complete all as specified and directed. | 20 | RM | |
42 | 42 | S&F steel water tubes medium grade, galvanised with all fittings 20mm bore fixed complete to walls and ceiling or laid in floors trenches including taking up or down steel tubing and connections, 20mm bore complete all as specified and directed. | 5 | RM | |
43 | 43 | S&F rotational moulded polyethylene water storage tanks 500 litre capacity, in white colour (cylindrical vertical with closed top) hoisted and fixed in position icluding dismantling of old water tanks complete all as specified and directed. | 5 | Each | |
44 | 44 | S&F rotational moulded polyethylene water storage tanks1000 litre capacity, in white colour (cylindrical vertical with closed top) hoisted and fixed in position dismantling of old water tanks complete all as specified and directed. | 1 | Each | |
45 | 45 | S&F in repair 20 mm PTMT float valve, high pressure with Polythene floot and flynut complete, screwed for Iron pipe etc complete all as specified and directed. | 15 | Each | |
46 | 46 | S&F in repair 20mm dis gun metal gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. | 5 | Each | |
47 | 47 | S&F in repair long body 15 mm bore bib tap, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified & directed. | 50 | Each | |
48 | 48 | S&F in repair 15mm dia concealed stop valves concealed type CP with fancy type, chromium plated with long shank and cup, complete all as specified and directed. | 5 | Each | |
49 | 49 | S&F in repair 15mm dia C P stop valve/angle cock chromium plated with fancy type handle screwed down, screwed for iron pipe of brass ferrule complete all as specified and directed. | 10 | Each | |
50 | 50 | S&F in repair brass chromium plated shower rose with swivel joints 125mm dia incl arm fixing to steel pipe or union complete all as specified and directed. | 5 | Each | |
51 | 51 | S&F in repair health foucet (hand shower) 80 mm dia, 1.00 m long flexible metal tube and wall hook/holder in polished crome complete all as specified and directed. | 5 | Each | |
52 | 52 | S&F in repair 15mm bore pillar taps, chromium plated, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. | 5 | Each | |
53 | 53 | M&L in repair for vitreous china wash basin, white, flat, back, size 580x450mm excluding taps, waste, china & plug & porcelain stopper but including brackets complete all as specified and directed. | 5 | Each | |
54 | 54 | S&F, in repair for waste coupling, brass, chromium plated for basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed 32mm bore, complete all as specified and directed. | 5 | Each | |
55 | 55 | S&F, in repair 32 mm bore Low density PVC flexible pipe for Wash hand basin/sink etc complete all as specified and directed. | 30 | Each | |
56 | 56 | S & F, in repair PVC connections 15 mm size with PTMT nuts of length 450 mm all as specified and directed. | 25 | Each | |
57 | 57 | S & F in repair CP grating with or witout waste hole size 100 mm fixed with white cement in tiles flooring complete all as specified and directed. | 10 | Each | |
58 | 58 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed. | 110 | Sqm | |
59 | 59 | M&L glazed ceramic joint free coloured tiles in vertical surfaces 600x300x7mm thick, set and joiunted in neat cement slurry and pointed in coloured cement to match over and including 10mm thick screed bed in cement mortar 1:3 complete all as specified and directed. | 60 | Sqm | |
60 | 60 | M&L coloured non skid ceramic jointless tiles 7 to 8mm thick (square/rectangular) are of each tile exc 0.11 Sqm but not exc. 0.18 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer with CM 1:4 complete all as specified and directed. | 30 | Sqm | |
61 | 61 | M&L for non skid ceramic (coloured) jointless tiles of 7-8 mm (square or rectangular) area of each tile exceeding 0.18 sqm but not exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 15mm thick screed CM 1:4 complete all as specified and directed. | 20 | Sqm | |
62 | 62 | Dismantling of stone slabs and tiles laid dry of any description or thickness in floor, aprons etc complete all as specified and directed. | 100 | Sqm | |
63 | 63 | M&L for machine pressed precast concrete interlocking paver block, ruberised, glossy finish any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment complete all as specified and directed. | 100 | Sqm | |
64 | 64 | M&L for sand under floor or paving laid in layers not exc 15cm thick, spread, levelled and rammed complete all as specified and directed. | 2 | Cum | |
65 | 65 | Dewatering of soak well , septic tanks by using mechanical pump diesel driven with fuel operator and crew of water etc at site complete all as specified and directed. | 2000 | Cum | |
66 | 66 | Cleaning of soak well, septic tanks by way of desludging foreign material manually/mechanically and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off outside of MOD premises (at the location notified by the local Municipal Corporation/ Cantt board as per rules of public health), including digging required nos of pits for depositing sludge and future capping the pit with the 25 cm thick layer of soil and sprinkling bleaching powder (including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed. | 150 | Cum | |
67 | 67 | Cleaning of blockage of 150mm bore sewer lines (i.e. branch sewer line, main sewer line) by way of cleaning desludging foreign material as well as roding of sewer line between successive manholes manually/mechanically or pumping out sewage from blocked line including desludging where required and ordered by Engineer-in-Charge and keeping sewer line functional from Ist manhole upto final drop as septic tank, soakage well all as specified and directed . \nNote for item no-65 to 67\n1.The cleaning shall be carried out with mechanized operation by means of diesel / electric operated vehicle mounted hydraulic operated high pressure suction -cum -jetting machines fitted with pump of required capacity and the sludge sucked out with Super Succer Machine of required capacity and sent to storage tanks for further disposal to the authorised disposal site land at any distance and without any additional cost. \n 2. The sludge deposited in sewage line shall be fully cleaned and disposed off the same outside the MOD land at any distance and without any additional cost , on the same day when it was taken out.The job shall be carried out with safety precaution equipment and with strict supervision .\n3. During the mechaized operation , the service provider /Contractor shall be equiped with Gas monitor , nylon rope ladder , torch light and compressor blower etc along with the sewage cleaning truck mounted suction / jetting machine . \n4. The unit rate quoted by the contractor shall interalia deemed into the cost of providing skilled driver and operator and supervising engineer including provision of water for jetting & removal of sludge /silt /liquid /mud & sand (in foul position )etc. \n5. The contractor shall engage the above mentioned T & P and intimate to Enginner - In -Charge in writing with Machine No./ Vehicle No. etc for their record and prior approval .\n6. A Register shall be maintained showing the Machine No /Vehicle No. and their deployment at site mentioning time and date duly sighned by concern JE , Engr -in- charge and contractor and the same register shall be produced while claiming the payment by the tenderer .\n | 5385 | RM | |
68 | 68 | Cleaning of all manholes upto 1.5 meter depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soil and sprinkling powder (including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed. | 1500 | Each | |
69 | 69 | Cleaning of all manholes upto 3.00 meter depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soil and sprinkling powder ( including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed. | 500 | Each | |
70 | 70 | Cleaning of all blockages of Nahni traps/floor traps/bottle traps, blockages of WC's, upto 1st manhole/Gully Trap in shafts, vertical CI soil/waste pipe stacks, CI Tee/door bends etc & cleaning of drain pipes of any dia by rodding and removal of sludge/silt/liquid mud sand (in foul conditions) etc, out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board). To Maintain of internal & external sewage system in functional state at all the time by engaging/deploying minimum One Safaiwala alongwith one Helper from 0900 hours to 1700 hours at Complaint cell of AGE B/R-II area mentioned in the contract on daily basis, with manual/ pressure cleaning pump and flexible rods and other necessary equipments (as per rules of public health), complete all as specified and directed.\nNote :- For item No- 68 to 70\n1. The Nos of person indicated in above items as assumed by the department, shall remain present at the complaint cell of AGE B/R-II area mentioned in CA. Contractor may have to deploy more manpower in the particular area and deploy adequate sewage cleaning machinary/ equipments to clean the line and open blockages. Rates quoted shall be deemed to have considered in the items all such contingencies. \n2. In case of non availability/ absence of any of minimum required man power, the recovery for the same shall be effected @ Rs 500.00 per day for the absence period proportionaly.\n3. If necessiated by the Engr-in-charge/GE for work on Sunday/ holidays, the contractor shall provide tradesmen with helpers.\n4. Proper records (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained and shall be produced for verification at the time of payment of each RAR/Bill.\n\n\n | 1800 | Each | |
71 | 71 | M&L for factory made RCC man hole cover /drain cover with cover frame comprising of 75mm thick cover, including provision of hot dip galvanized lifting hook for lifting overall cover with suitable size angle iron frame, RCC cover of M-30 grade concrete by vibro compression process, medium duty confirming to IS-12592 including fixing on manhole, demolition of existing coverwith cover frame and removal of debris from site complete all as specified and directed. Note : The factory made RCC cover shall be ISI marked and as approved. | 50 | Sqm | |
72 | 72 | Removal of debrish exc. 1.50 km but not exc. 5 km and\ndepositing where directed at a level complete all as specified and directed. | 10 | Cum |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy