Rural Development And Panchayats Department has published Electrification Of 09 Nos Of Pyt Ghrs Amb Block Bhalwal , Jandyal Upper Block Mathwar , Kathar Block Dansal , Kot-Ghari Block Akhnoor , Keri Block Mathwar , Balgara Block Maira Mandiran , Rah Block Chowki Choura , Badsoo Dansal , Juthal Balsaroo Block Ch. Submission Date for this Tender is 22-01-2021. Electrification Work Tenders in Jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Name of Work: Electrification of 09 Nos of newly constructed Panchayat Ghars namely 1. Amb, Panchayat Amb Block Bhalwal 2. Jandyal Upper Pyt. Jandyal Block Mathwar, 3. Kathar Upper Pyt. Kathar Block Dansal 4. Kot-Ghari Pyt. Kot Ghari Block Akhnoor 5.Keri Pyt. Keri Block Mathwar, 6.Balgara Pyt Balgara Block Maira Mandiran, 7.Rah Pyt. Rah Block Chowki Choura, 8.Badsoo Pyt. Badsoo block Dansal, 9. Juthal Balsaroo Pyt Juthal Block Chowki Choura of District Jammu. (Estt. cost. 11.16 lacs) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C | BI01010001010000000000000515BI0100001113 | 360 | Point |
2 | 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | BI01010001010000000000000515BI0100001114 | 1890 | metre |
3 | 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | BI01010001010000000000000515BI0100001115 | 1800 | metre |
4 | 4 | Supplying of FRLS PVC insulated copper conductor, single core cable in the existing surface/ PVC conduit as required.1x10 sq. mm | BI01010001010000000000000515BI0100001116 | 270 | metre |
5 | 5 | Supplying and fixing of following sizes of medium class PVC\nconduit along with accessories in surface/recess including\ncutting the wall and making good the same in case of recessed\nconduit as required.25 mm | BI01010001010000000000000515BI0100001117 | 225 | metre |
6 | 6 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 2 Module (75mmX75mm) | BI01010001010000000000000515BI0100001118 | 117 | Each |
7 | 7 | Supplying and fixing following modular switch/ socket on the\nexisting modular plate & switch box including connections but excluding modular plate etc. as required 6 pin 15/16 A socket outlet | BI01010001010000000000000515BI0100001119 | 117 | Each |
8 | 8 | Supplying and fixing two module stepped type electronic fan\nregulator on the existing modular plate switch box including\nconnections but excluding modular plate etc. as required | BI01010001010000000000000515BI0100001120 | 63 | Each |
9 | 9 | Supplying and fixing Ceiling Fan of 1200mm sweep.Make Usha,Havells or eqvt | BI01010001010000000000000515BI0100001121 | 63 | Each |
10 | 10 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. | BI01010001010000000000000515BI0100001122 | 63 | Each |
11 | 11 | Supplying and fixing PVC batten/ angle holder including\nconnections etc. as required. | BI01010001010000000000000515BI0100001123 | 108 | Each |
12 | 12 | Supplying and fixing LED T5 tube light of 20W.Make Havells,Syska or eqvt | BI01010001010000000000000515BI0100001124 | 108 | Each |
13 | 13 | Installation, testing and commissioning of pre-wired,\nfluorescent fitting / compact fluorescent fitting of all types,\ncomplete with all accessories and tube/lamp etc. directly on\nceiling/ wall, including connections with 1.5 sq. mm FRLS PVC\ninsulated, copper conductor, single core cable and earthing etc. as required. | BI01010001010000000000000515BI0100001125 | 216 | Each |
14 | 14 | Supplying ,testing and fixing LED light of 12W including connection complete job.Make Havells,Syska or eqvt | BI01010001010000000000000515BI0100001126 | 108 | Each |
15 | 15 | Supplying and fixing following way, single pole and neutral,\nsheet steel, MCB distribution board, 240 V, on surface/ recess,\ncomplete with tinned copper bus bar, neutral bus bar, earth\nbar, din bar, interconnections, powder painted including\nearthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door | BI01010001010000000000000515BI0100001127 | 18 | Each |
16 | 16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"\ncurve, miniature circuit breaker suitable for inductive load of\nfollowing poles in the existing MCB DB complete with\nconnections, testing and commissioning etc. as required.Single pole and neutral | BI01010001010000000000000515BI0100001128 | 90 | Each |
17 | 17 | Supplying and fixing following rating, double pole, 240 V,\nisolator in the existing MCB DB complete with connections,\ntesting and commissioning etc. as required.63 A | BI01010001010000000000000515BI0100001129 | 9 | Each |
18 | 18 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm\nthick including accessories, and providing masonry enclosure\nwith cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required | BI01010001010000000000000515BI0100001130 | 9 | Set |
19 | 19 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below\nground level for conductor earth electrode, including\nconnection/ termination with GI thimble etc. as required. | BI01010001010000000000000515BI0100001131 | 468 | metre |
20 | 20 | Providing and fixing circular/hexagonal cast iron box for ceiling fan clamp of internal dia 140 mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3mm dia. round headed screws,one lock at the corners. Clamps shall be made of 12mm dia M.S. bar bent toshape as per standard drawing. | BI01010001010000000000000515BI0100001132 | 63 | Each |