Military Engineer Services-MES has published Repair /Maint Of Perimeter Cables , High Mast Light , Junction Boxes And Connected Items At Army Area Banar , Jodhpur. Submission Date for this Tender is 03-02-2021. Distribution Box Tenders in BANAR Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

26525486
Corrigendum : Repair /Maint Of Perimeter Cables , High Mast Light , Junction Boxes And Connected Items At Army Area Banar , Jodhpur
Open Tender
Indian
Rajasthan
BANAR
03-02-2021

Tender Details

Repair /Maint Of Perimeter Cables , High Mast Light , Junction Boxes And Connected Items At Army Area Banar , Jodhpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jan-2021 Corrigendum No.01 BOQ 27-01-2021
2 15-Jan-2021 Corrigendum No.01 BOQ 27-01-2021
3 27-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work: REPAIR /MAINT OF PERIMETER CABLES, HIGH MAST LIGHT, JUNCTION BOXES AND CONNECTED ITEMS AT ARMY AREA BANAR, JODHPUR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down old unserviceable LT UG cable and Supply and laying, testing, commissioning in replacement of LT underground cables, 1100 volts grade XLPE insulated, PVC sheathed, heavy duty armoured, with multistranded aluminium conductors with IS-1554 marked, laid in trenches or fixed to wall / poles, passing through pipe of cross sectional area 16 Sqmm 2 core.\nNote for Item No 1.00 to 4.00 : The cost of heavy duty lugs/thimbles to crimp the LT cable shall be deemed to be included in the unit rate quoted for this item.\n 300 RM
2 2 All as per item No 1 above but 10 Sqmm 4 core.\n\n 1100 RM
3 3 All as per item No 1 above but 50 sqmm 3.5 core. 700 RM
4 4 All as per item No 1 above but 70 sqmm 3.5 core. 800 RM
5 5 Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out for laying of cables complete all as specified and directed by Engineer-in-Charge. 705 Cum
6 6 All as per item No 5 here-in-before but exc 1.5 mtr but not exc 3.00 mtr. 0.5 Cum
7 7 Returning and filling in including spreading, levelling , watering and well ramming in layers not exceeding 25 cm thick of excavated earth complete all as specified and directed. 462 Cum
8 8 Removal of surplus soil to a distance not exceeding 50 mtr and depositing at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed. 243 Cum
9 9 M&L for tibba sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of underground cable 23 cm thick complete all as specified and directed.\nNote :- (i) For the purpose of payment, punned thickness 18 cm shall be measured. \n (ii) Tibba sand shall be stored properly and record of tibba sand through out shall be entered in MB as \n "Not to be Abstracted". 211 Cum
10 10 Labour only for relaying the Jodhpur stone quarry stone slab cover 25 to 30 cm in width, 60cm minimum long and 40 to 50mm thick laid in trenches and abutting each other with gap between adjacent slab not exceeding 10mm over sand covered underground cables complete all as specified and directed by Engineer-in-Charge. (Jodhpur quarry stone obtained from item 1 to 4 shall be re-used after cleaning). 65 Sqm
11 11 M&L for laying Jodhpur stone quarry stone slab cover 25 to 30 cm in width, 60cm minimum long and 40 to 50mm thick laid in trenches and abutting each other with gap between adjacent slab not exceeding 10mm over sand covered underground cables complete all as specified and directed by Engineer-in-Charge. 629 Sqm
12 12 S & F in replacement of galvanised tubes 50 mm bore light grade with necessary accessories/ fittings laid in trenches /pole coping, made curved bend of 900 by to free run the cable through pipe from trench level including all necessary clamps if required complete all as specified and directed. 40 RM
13 13 S & F in replacement of galvanised tubes 80 mm bore light grade with necessary accessories/ fittings laid in trenches including all necessary clamps if required complete all as specified and directed. 10 RM
14 14 Supply and fixing the flexible PVC pipe green and white color mixed (spiral pipe) 50 mm dia to fit with GI pipe to make free curve to run the LT cable inside LT poles coping with proper bracing clamps complete all as specified and directed. 50 RM
15 15 Supply and erecting in replacement of Pre-stressed concrete pole, 9.0 meter long, 102mm x 152 mm at top and 102 mm x 289 mm at bottom, class 10 including painting alternative black & white strips of 30 cm width upto 1.5 mtr above ground level and including dismantling and taking out the damaged/old PCC pole and remaining outside defence land as directed by Engr-in-Charge. Distance and opening the street light bracket, street light fittings from old pole and re-fixing the same on new pole for street light fitting complete all as specified and directed by Engr-in-Charge. 3 Each Job
16 16 Supply and fixing in replacement of 40 mm dia GI pipe bracket (light grade) bent to shape of length not less than 1.2 mtr including fixing on wall /pole using flat iron clamps of suitable size nuts, bolts, washers etc including paint of two coats of alluminium paint over one coat of red oxide primer suitable for street light fittings all as specified and directed by Engr-in-Charge. 4 Each Job
17 17 M&L for cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) for foundation of pole / stay including necessary form work complete all as specified and directed. \n 4 Cum
18 18 M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) for coping of poles or in base of plate form or including form work in any situation complete all as specified and directed. \n 3 Cum
19 19 Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil all complete all as specified and directed. 1 Sqm
20 20 M&L for cutting the road / hard standings and excavating in trenches not exc 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by using PCC 1:2:4, type B1 using 20 mm graded stone aggregate) complete and matching with the surroundings all as directed. 10 RM
21 21 Supply and Fixing in replacement of loop-in / loop-out box of outer size 205x255x112mm made out of FRP body (hot moulded type) with IP-66 protection and locking with screws alongwith 5/6 Amp rating MCB SP-01 No, up to 50 Amp rated 3 pole connector suitable to insert the cable size 25 Sqmm-01 No, with neutral link and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts for suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and outgoing cables complete all as specified and directed. 30 Each
22 22 M&L for repairs to High Mast of 12.5 mtr to 16 Mtr height lantern carriage /winch, checking for movement, inspecting the alignment, replacement of broken / defective SS wire rope of size 6 mm, 7/19 construction complete, replacement of 5 core 2.5 Sqmm flexible copper conductor, ERP insulated PCP/PVC sheathed trailing cable complete, testing & commissioning complete all as directed by Engr-in-Charge. 1 Each Job
23 23 Labour for de-carbinising the electric connection connected from street light fitting to OH conductor /junction box by making fresh connection tightening properly on LT PCC / Steel pole at the height upto 12 Mtr complete all as specified and directed. 100 Each Job
24 24 Fixing only street light fitting LED type of 90/110/120/150 watt and any size suitable for mounting on 40 mm dia FI mast or bracket arms with pole fixing attachments and proper fixing /connecting of service cable from pole box to street light fitting including taking out old existing light fitting complete all as specified and directed by Engr-in-Charge.\nNote:- LED street light luminaries shall be issued to contractor under Schedule 'B' free for fixing. 20 Each
25 25 Fixing only LED flood light luminaries 100/120/150 watt mounted on bracket at height of 6 mtr on pole /high mast including taking out existing flood light fittings complete all as specified and directed by Engr-in-Charge.\nNote:- LED street light luminaries shall be issued to contractor under Schedule 'B' free for fixing. 15 Each
26 26 Supply and fixing in replacement of Rigid non-metallic PVC conduit 20 mm dia exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts, saddles, pipe hooks etc on steel tubular/PCC/RCC Poles and all as specified and directed. 100 RM
27 27 Supply installation, testing and commissioning in replacement of panel board 3 phase and neutral 415 volt outdoor type factory made free standing, inter locking arrangement, floor mounting, dust and vermin proof cubical type IP-54 protecting fabricated with 3.15 mm thick CRCA sheet outer shell and 2.0 mm thick CRCA sheet of inner shell with anti-corrosive coating and finally polyester powder coating in finite grade shade fully compartmentalised design with 4 No's of aluminium bus bar of 300 Amp pre-wired with suitable size of aluminum strip with sleeves of suitable colour including suitable GI strip (for earth) and 25x3 mm thick angle iron and PCC work for foundation including taking down the old unsv LT panel and all as specified with supply and fixing all as required and directed at site (Near Gd Post No -02 & 03 of FAD Perimeter) for the following:-\n\n 2 Each
28 27.01 (a) Incoming:- \n (i) MCCB 160 Amps 35/36 KA, 4 pole, 415 volts thermal magnetic release type - 01 No.\n (ii) Ammeter 0 to 300 Amp digital type with suitable ratio of CT's\n (iii) Voltmeter 0 to 500 volts digitals type having arrangement to check phase to phase, phase to\n neutral\n (iv) Indicating lamp\n (v) Bus bar chamber having insulated aluminium bus bar 300 Amp and neutral.\n (vi) Chamber of suitable size for incoming and outgoing cables with arranging of suitable size cable \n glands.
29 27.02 (b) Outgoing:-\n (i) MCCB 100 Amps 25 KA 415 volts 4 pole with adjustable thermal release - 2 No\n (ii) MCB 40 Amps 10 KA 230 volts single pole and neutral Ç'Series - 02 No. \n (iii) MCB TPN 63 Amps 415 volts 10 KA Ç'Series - 01 No. \n (iv) Contractor TP 50 amps - 01 Nos with operating coil 240 volts. \n (v) Digital time switch 2 module type 24 hrs with DC battery for power back up.\n (vi) By pass arrangement with toggle switch to operate the street lights for maintenance /checking as \n per requirement. \n (vii) Necessary connection with 4 Sqmm copper wire for all measuring maters and other connected \n instruments to smooth function of measuring instruments all as required and directed.\n\n\n
30 28 Material and labour for Earthing in replacement with galvanised steel earth plate electrode 600x600x6.00mm buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to galvanised iron earth lead strip of size 32x6mm dia by means of bolts, nuts washers of galvanised iron or steel all as shown in electrical plate No 3 of MES SSR Part I connected to earthing test point on completion with and including 40 mm bore GI light grade protection pipe for earth lead GI lead wire 32x6 mm dia and 15 mm dia GI pipe for watering PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia for bars @ 80 mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work complete all as specified and directed by Engineer-in-Charge.\nNote:-Earthing shall be tested by Engr-in-Charge in presence of the contractor and payment for earthing shall be admissible only after satisfactory test result. 4 Each Set
31 29 Supply and connecting in replacement of PVC wire 2.5 sqmm nominal area 3 core multi standed copper conductor PVC sheathed and weather proof round / flat shape and drawn through PVC conduit and connecting to Street light fitting on PCC/RCC/Steel pole with PVC connector near to light fitting and copper thimble in junction box terminal complete all specified and directed at site by Engr-in-charge. 200 RM