}

Provision Of Deficient Infrastructure For New Armament At Nad Visakhapatnam, Visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Provision Of Deficient Infrastructure For New Armament At Nad Visakhapatnam. Submission Date for this Tender is 30-01-2021. Infrastructure Work Tenders in Visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26523853
Corrigendum : Provision Of Deficient Infrastructure For New Armament At Nad Visakhapatnam
Open Tender
Indian
Andhra Pradesh
Visakhapatnam
30-01-2021

Tender Details

Provision Of Deficient Infrastructure For New Armament At Nad Visakhapatnam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-01-2021

Key Value

Document Fees
INR 3000 /-
EMD
INR 1130500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVISION OF DEFICIENT INFRASTRUCTURE FOR NEW ARMAMENT AT NAD VISAKHAPATNAM
Sl. No. Item Description Item Code / Make Quantity Units
1 0 Schedule "A" Part – I to Schedule "A" Part – XIV:\nNOTE: Schedule "A" Part – I to Part – XIV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
2 1 Lumpsum price worked out by the contractor for "Buildings & Structures", as listed in Schedule "A" Part – I on Serial Page No. 37 BI01010001010000000000000515BI0100001111 1 Each Job
3 2 Lumpsum price worked out by the contractor for "Site Clearance / Area Development / Earthwork Excavation", as listed in Schedule "A" Part – II on Serial Page No. 39 BI01010001010000000000000515BI0100001112 1 Each Job
4 3 Lumpsum price worked out by the contractor for "Pile foundation", as listed in Schedule "A" Part – III on Serial Page No. 40 BI01010001010000000000000515BI0100001113 1 Each Job
5 4 Lumpsum price worked out by the contractor for "Road/Path/ Culvert", as listed in Schedule "A" Part – IV on Serial Page No. 43 BI01010001010000000000000515BI0100001114 1 Each Job
6 5 Lumpsum price worked out by the contractor for "Area Drainage", as listed in Schedule "A" Part – V on Serial Page No. 45 BI01010001010000000000000515BI0100001115 1 Each Job
7 6 Lumpsum price worked out by the contractor for "Sewage Disposal", as listed in Schedule "A" Part – VI on Serial Page No. 48 BI01010001010000000000000515BI0100001116 1 Each Job
8 7 Lumpsum price worked out by the contractor for "Chemical Earthing", as listed in Schedule "A" Part – VII on Serial Page No. 49 BI01010001010000000000000515BI0100001117 1 Each Job
9 8 Lumpsum price worked out by the contractor for "Internal Water Supply", as listed in Schedule "A" Part – VIII on Serial Page No. 51. BI01010001010000000000000515BI0100001118 1 Each Job
10 9 Lumpsum price worked out by the contractor for "Internal Electrification", as listed in Schedule "A" Part – IX on Serial Page No. 53 BI01010001010000000000000515BI0100001119 1 Each Job
11 10 Lumpsum price worked out by the contractor for "External Water Supply", as listed in Schedule "A" Part – X on Serial Page No. 55. BI01010001010000000000000515BI0100001120 1 Each Job
12 11 Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – XI on Serial Page No. 59. BI01010001010000000000000515BI0100001121 1 Each Job
13 12 Lumpsum price worked out by the contractor for "Lightening Protection", as listed in Schedule "A" Part – XII on Serial Page No. 60. BI01010001010000000000000515BI0100001122 1 Each Job
14 13 Lumpsum price worked out by the contractor for "Fire Fighting System", as listed in Schedule "A" Part – XIII on Serial Page No. 62 BI01010001010000000000000515BI0100001123 1 Each Job
15 14 Lumpsum price worked out by the contractor for "Fire Alarm System", as listed in Schedule "A" Part – XIV on Serial Page No. 63 BI01010001010000000000000515BI0100001124 1 Each Job
16 15 Schedule "A" Part - XV: [Miscellaneous Items] [Pile foundation, Road/Path Culvert, Internal Electrification, External Water Supply, External Electric supply, Lightening Protection, Fire Fighting System, Fire Alarm System, Air Conditioning, Air Compressor, Air curtain, Arboriculture, EOT Crane, DG Set and Power supply]: BI01010001010000000000000515BI0100001125
17 16 PILE FOUNDATION BI01010001010000000000000515BI0100001126
18 17 Boring for bored cast in situ piles 450mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil to a distance not exceeding 10KM out side MD land using hydraulic rig method complete all as specified and directed. BI01010001010000000000000515BI0100001127 4512 RM
19 18 Boring for bored cast in situ piles 450mm dia in hard rock & fractured rock and getting out and disposal of spoil to a distance not exceeding 10KM out side MD land using hydraulic rig method complete all as specified and directed. BI01010001010000000000000515BI0100001128 564 RM
20 19 Chipping out piles up to cut off level including disposal of spoil to a distance not exceeding 50M out side MD land all as specified and as directed. BI01010001010000000000000515BI0100001129 59.81 Cum
21 20 Carrying out Initial load test on 450mm dia piles all as per IS - 2911 Part - IV . BI01010001010000000000000515BI0100001130 1 Each
22 21 Carrying out routine load test on 450mm dia piles all as per IS - 2911 Part - IV. BI01010001010000000000000515BI0100001131 8 Each
23 22 Carrying out initial lateral test on 450mm dia piles all as per IS - 2911 Part - IV. BI01010001010000000000000515BI0100001132 8 Each
24 23 Carrying out initial pullout test on 450mm dia piles all as per IS - 2911 Part - IV. BI01010001010000000000000515BI0100001133 8 Each
25 24 Carrying out low strain energy test on 450mm dia piles including analyzing the results as per IS - 14893- 2001. BI01010001010000000000000515BI0100001134 359 Each
26 25 ROAD/PATH/CULVERT BI01010001010000000000000515BI0100001135
27 26 Granular Sub Base (GSB) with grading V of 150mm thick compacted thickness (laid in two layers of 75mm each, compacted separately) confirming to grading as specified, spread, rolled and consolidated to required gradient and camber complete using necessary mechanical paver/ Grader and Vibratory soil compacter of capacity 8-10 Ton all as specified and as directed.\n(a) Pavement shall be made for solid quantity arrived after consolidation.\n(b) Compaction of granular sub base filling shall be carried out under optimum moisture condition to achieve 98.50 modified density.\n(c) Curing shall be carried out as per IRC recommendations.\n(d) Before execution of this item the approved material obtained from outside MD land shall be tested/checked for suitability to use.\n(e) The Lead/Royalty involved is to be ascertained by the contractor before quoting his tender and no extra payment/adjustment for increased in lead or Rate of Royalty due to whatever reason shall be admissible on his account.\n(f) Contractor shall use Vibratory earth compactor in lieu of power roller to achieve 98.00% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC.\n(g) GSB shall be as per MORTH Specifications as detailed in Particular specification. BI01010001010000000000000515BI0100001136 183 10 Sqm
28 27 Wet mix Macadam of 250mm thick (compacted thickness ) laid in three layer compacted separately with Coarse aggregate of specified grade spread rolled and consolidated to required gradient and camber complete using mechanical paver/Grader and Random, Vibrator of capacity of minimum 8-10 Tons at OMC to achieve at least 98% MBB determined using modified proctor density determination method as per IS Code on prepared GSB surface complete all as specified and as directed.\nNOTE: The rate quoted shall be for 250mm compacted thickness.\nEach layer shall be rolled separately . BI01010001010000000000000515BI0100001137 180 10 Sqm
29 28 Material and labour for painting lines, dashes, arrows, letters etc on road surface with hot applied retro reflective thermoplastic paint confirming to MORTH (Clause 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement up to 160 C, including cleaning and drying the road surfaces to ensure dust, oil, grease and moisture free surface before applying paint complete all as specified and as directed. BI01010001010000000000000515BI0100001138 60 Square Meter
30 29 INTERNAL ELECTRIFICATION BI01010001010000000000000515BI0100001139
31 30 Point wiring with 1.5 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed including provn of pressed steel terminal box of suitable size fabricated out of 2 mm thick for modular brackets, including modular brackets and plates as required at site for fixing switches, sockets, including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly for One Light / Fan Point / Bell Point /Wall Fan / Exhaust Fan controlled by One Switch complete all as specified. BI01010001010000000000000515BI0100001140 225 Per Point
32 31 Point wiring with 1.5 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed including provn of pressed steel terminal box of suitable size fabricated out of 2 mm thick for modular brackets, including modular brackets and plates as required at site for fixing switches, sockets, including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly for one 3 Pin Socket outlet 5 Amps socket on Independent Board complete all as specified. BI01010001010000000000000515BI0100001141 47 Per Point
33 32 Point wiring with 1.5 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed including provn of pressed steel terminal box of suitable size fabricated out of 2 mm thick for modular brackets, including modular brackets and plates as required at site for fixing switches, sockets, including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly for one Light Point controlled by two Switch complete all as specified. BI01010001010000000000000515BI0100001142 2 Per Point
34 33 Point wiring with 2.5 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed including provn of pressed steel terminal box of suitable size fabricated out of 2 mm thick for modular brackets, including modular brackets and plates as required at site for fixing switches, sockets, including one run of 2.5 sqmm PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly for one 3 Pin Socket outlet 15 Amps socket on Independent Board complete all as specified. BI01010001010000000000000515BI0100001143 56 Per Point
35 34 S & F Energy efficient 4 ft ultra slim square profile LED light fixture with high lumen out put 22 watt LED 6500K, 230V surface mounted and robust construction with necessary acrylic cover as diffuser with mounting bracket etc including connecting up with 1.0 sq mm 3 core copper conductor cable complete all as specified. BI01010001010000000000000515BI0100001144 80 Each
36 35 S & F Energy efficient ultra slim square profile LED light fixture with high lumen out put 10 watt LED 6500K, 230V surface mounted and robust construction with necessary acrylic cover as diffuser with mounting bracket etc including connecting up with 1.0 sq mm 3 core copper conductor cable complete all as specified. BI01010001010000000000000515BI0100001145 11 Each
37 36 S & F energy saving, environment friendly & robust IP65 protected LED light fitting mid bay with PDC housing suitable for ceiling suspended mount 60 W including connecting with1.0 sq mm 3 core multistranded copper conductor cable up to ceiling rose and fixing bracket complete all as specified. BI01010001010000000000000515BI0100001146 12 Each
38 37 S & F energy saving, environment friendly & robust IP65 protected LED light fitting high bay with PDC housing suitable for ceiling suspended mount 100 W including connecting with1.0 sq mm 3 core multistranded copper conductor cable up to ceiling rose and fixing bracket complete all as specified. BI01010001010000000000000515BI0100001147 42 Each
39 38 S & F LED Security light fitting with tube 20W New generation Energy saving & environmental friendly long life versatile pressure die cast aluminium luminaries with mid power LEDs as source and HF electronic driver pre wired with 1.0 Sq mm copper conductor cable up to connector including 2 Mtr long GI Tubing Medium grade suitable dia bend to shape fixing on wall with suitable MS brackets complete all as specified.\n BI01010001010000000000000515BI0100001148 14 Each
40 39 S & F LED flood light fitting with tube 50W New generation Energy saving & environmental friendly long life versatile pressure die cast aluminium luminaries with high power LED as light source pre wired and connection with 1.0 Sq mm 3 core copper conductor cable up to connector including suitable bracket for fixing on wall complete all as specified.\n BI01010001010000000000000515BI0100001149 3 Each
41 40 Supply and fixing ceiling fans AC single phase 230 V of size 1200 mm sweep with complete set with fixtures, 5 Star rating, metallic body complete all as specified.\n BI01010001010000000000000515BI0100001150 26 Each
42 41 S&F Exhaust fan 200 mm sweep or nearest size, plastic body(Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the disturbed surfaces etc complete all as specified and as directed.\n BI01010001010000000000000515BI0100001151 5 Each
43 42 S&F Exhaust fan 450 mm sweep or nearest size, plastic body(Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the disturbed surfaces etc complete all as specified and as directed.\n BI01010001010000000000000515BI0100001152 5 Each
44 43 S&F Air circulator 600 mm sweep or nearest size, Heavy duty, wall mounting complete suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall complete all as specified and as directed.\n BI01010001010000000000000515BI0100001153 23 Each
45 44 S&F concealed in wall Vertical DB double door TPN 6 way 415V, 50Hz double door, IP 43 protection with 200A rated bus bar , including provision for MCCB TP 160 amp as incomer and outgoing circuits MCB SP/TP complete, fill empty with blanks complete all as specified and directed. BI01010001010000000000000515BI0100001154 1 Each
46 45 Material & Labour Sub main wiring concealed for single phase supply with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire with PVC rigid conduit medium grade of suitable size with accessories for 2 runs 6.0 sq mm and 1 runs of 6.0 sq mm complete all as specified\nNote: 3 runs of 6mm cable and 1 run of PVC rigid conduit will be measured as one unit BI01010001010000000000000515BI0100001155 750 RM
47 46 Earth continuity conductor fixed to wall on battens or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other location for loop earthing etc 4mm dia Galvanized Iron wire complete all as specified. BI01010001010000000000000515BI0100001156 15 RM
48 47 EXTERNAL WATER SUPPLY BI01010001010000000000000515BI0100001157
49 48 Construction of Valve Chamber of size 750 X 750 X 750 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified and shown on drawing CEDD / TD / 119, Sheet No. 1 / 1 dated 20 August 1983, revised up to 21 September 1992. BI01010001010000000000000515BI0100001158 2 Each Job
50 49 Cutting existing steel tubing of 150 dia for alterations or additions necessarily done in position without taking down, dewatering for inserting flanged sockets, 'Tee' with reducer to 80 mm, etc for tapping complete all as specified and directed. BI01010001010000000000000515BI0100001159 1 Each
51 50 EXTERNAL ELECTRIC SUPPLY BI01010001010000000000000515BI0100001160
52 51 Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor 11000 volts grade, of size 3 core 240 sq mm all as specified and as directed BI01010001010000000000000515BI0100001161 800 RM
53 52 Supply and lay cable XLPE of 3.5 Core 400 Sqmm FRLS Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed. BI01010001010000000000000515BI0100001162 280 RM
54 53 Supply and lay cable XLPE of 3.5 Core 240 Sqmm FRLS Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed. BI01010001010000000000000515BI0100001163 630 RM
55 54 Supply and lay cable XLPE of 3.5 Core 120 Sqmm FRLS Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed. BI01010001010000000000000515BI0100001164 310 RM
56 55 Supply and lay cable XLPE of 3.5 Core 50 Sqmm FRLS Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed. BI01010001010000000000000515BI0100001165 100 RM
57 56 Supply and lay cable XLPE of 4 Core 10 Sqmm FRLS Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed. BI01010001010000000000000515BI0100001166 300 RM
58 57 Design, Manufacture, Supply, Installation, Testing and Commissioning of 11 KV / 0.433 KV, 1000 KVA Factory Assembled, Factory Tested ready to install and connections type Compact Substation with an outdoor enclosure, equipped with 1000 KVA Ester oil cooled Transformer, 3 Way, 11 KV Ring Main Unit [SF6 Gas Insulated Switchgear] consisting of 2 Nos, 630A at 11 KV Fault Making Load Breaking Switch Two Load Breaking Switches & 01 Nos VCB SF6 Gas insulated Vacuum Circuit Breaker and with 1600 Amps, Air Circuit Breaker as secondary side control complete with HT Cable interconnection in between Transformer and RMU and suitable sized Bus bar between Transformer and LV Incoming Main Switchgear-ACB for full load output current of the transformer and Internal earthing connections by GI Strips all as a single transport unit complete all as specified as detailed below:\n[b] Enclosure: Outdoor type enclosure having modular construction with 2mm thick Galvanized Sheet Steel in Corrugated / Louvered design type wall design for better heat dissipation and providing robust construction. The degree of protection for HT & LT switchgear compartment shall be IP54 & degree of protection of transformer compartment of the enclosure shall be minimum IP34. The enclosure exterior shall be painted with polyurethane paint / epoxy powder coated and tropicalised to Indian weather conditions. Each compartment shall be provided with the door and pad locking arrangement. Doors of transformer compartment are fitted with Arc reflectors from the inside for providing better safety. The Compartment illumination lamp with door-operated switch shall be provided for each compartment. Structure of the substation shall be BI01010001010000000000000515BI0100001167 1 Each Job
59 58 able to withstand the gross weight of all equipment. \nThe Compact Substation shall be provided with lifting beams and hooks for easy installation at site and it shall be possible to transport the equipment along with Transformer, RMU & LT Panel from one site to another. Dimensions of enclosure shall be as per the components required and mentioned in BoQ. Final drawing shall be got approved from Accepting Officer. – 1 Nos\n[c] HT Switchgear [Inside Compact Sub-Station]: Three way 11KV, 630 Amps, 21 KA / 3 Sec Non-Extensible Ring Main Unit / Compact Switchgear with Copper Bus bar, consisting of 630 Amps, Two Numbers [As incomer] fixed Manual/Motorized Fault Making / Load Break Switches & One Numbers Fixed Manual/Motorized SF6 insulated Vacuum Circuit Breakers [As Outgoing] in SF6 Gas insulated sealed for life minimum 2 mm Thickness SS 441 stainless steel tank IP 67 degree of protection with Air Insulated Metering Module, One Number fault passage indicator shall be provided for each Load Break Switch with 1 NO + 1 NC Contact, One Number manometer shall be provided for outgoing feeders, One set of 100/1A, 2.5 VA, Class 1.0 for metering & One set of 100 / 1A, 2.5 VA, CL 5P 10 Current Transformers shall be provided, One number of Digital Multifunction Meter with RS 485 Port shall be provided for VCB Feeders, One Set of 11 KV / RT3 / 110 / RT3, Class 1.0, 20VA PTs shall be provided in Metering Module. Vacuum Circuit Breakers shall be with self-powered micro processor based Numerical Over Current and Earth Fault Relay having Charged Open / Closing Mechanism, On / Off Indicators, Mechanical Operation Counters etc. Interconnection between RMU and Transformer shall be using suitable Aluminium BI01010001010000000000000515BI0100001168
60 59 unarmoured 11 KV [UE] 1 X 3 Core X 240 Sq.mm or 3 X 1 Core X 240 Sq.mm XLPE cable.\n[d] Transformer [Inside Compact Sub-Station]: 1000 KVA, 11KV / 433V, 3 Phase, 50 Hz, DYn11, ONAN Cooling Natural Ester oil filled type, Copper Wound, CRGO Core Transformer with Off Circuit Tap Links of range +5% to –5% in steps of 2.5% on HT side of transformer, having Primary Voltage [HT] 11 KV and Secondary Voltage [LT] of 433 Volts, Delta connected on 11 KV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS – 1180 ,Level - II with latest amendments – 1 No.\n[e] LV Switchgear [Inside Compact Sub-Station]: 415 Volts, indoor LV Panel with Aluminium Bus bars [100% for Phase & 50% for neutral, fabricated using 2 mm thick CRCA Sheet Steel, Ingress Protection IP4X, Compartmentalized complete with internal wiring consisting of following:\n[i] Incomer: ACB, 1600 Amps, FP, 50 KA, 415 Volts, 3 Phase, 50 Hz, Fixed Manual type with Microprocessor based O/L, S/C, E/F Release – 1 Nos\n[ii] Metering for Incomer: Digital Multifunction Meter with A, V, KW, KWH, PF, Class 1.0 with Port – 1 Nos, LT Metering CT’s, 3200 / 1A, Cast Resin Type, Class - 0.5 – 1 Set, R, Y, B, ON, OFF, Trip LED Indicating Lamps – 1 Set, Control MCB, SP, 6 Amps – As required \n[iii] Suitable cable end box to be provided to connect two runs of 3.5 core, 400 Sqmm stranded Aluminium conductor cable at the out going of ACB. BI01010001010000000000000515BI0100001169
61 60 [f] Compact Substation shall be outdoor Plinth Mounted Type. The rate quoted is deemed to be including the cost of Erection, Commissioning of Compact Substation and Civil work such as Construction of foundation with Concrete / Brick masonry with plastering for the installation of Compact Substation of required size including trench for the cabling work etc. complete in all respect as directed by the GE. However the bidder shall furnish the foundation details for approval of GE before executing the work.\n[g] Compact Substation shall be complete with the internal interconnections & Earthing [GI] and extending of earth bar of Neutral and body terminals to the frame of the Compact Substation for connecting to the earth pits. \n[h] The bidder shall assemble the Compact substation at factory and no assembly of the same shall be allowed at site. Bidder shall be responsible for Installation & commissioning Compact substation. Technical data sheet of the Transformer, HV / LV Switchgear, Relay etc. shall be submitted to GE for approval before placing the supply order.\n[i] The equipments should be SCADA compatible in future by providing motor in future.\n[j] The bidder shall supply suitable & required no. of HT & LT Cable termination kits along with Compact Substation for HT & LT Cable terminations.[k] The Design for Internal Arc Fault shall be tested for 20KA for 1 Second as per IEC 1330/62271-202.\n BI01010001010000000000000515BI0100001170
62 61 [l] Pre-Dispatch Inspection: Bidder shall offer for pre-dispatch inspection at OEM works. Only after the equipments are cleared by the department in writing, the bidder can dispatch the equipment. Routine tests shall be conducted and original test certificates shall be submitted at the time of Pre-Dispatch Inspection. \n[m] Commissioning Spares: Additional commissioning spares such as Digital Multifunction Meter – 1 Nos, Indication lamps – 3 Nos, Protection Relay – 1 Nos, Spring Charging Handles – 2 Nos and Panel Keys – 2 Nos shall be provided by the bidder. \n[n] Suppressors or other protection devices shall be provided, if required as per schedule of quantities, wherever the sub-station installation is likely to interfere during the operation with any other electric or electronic equipment.\nLT panel:- LT FPB made out of 3.15 mm thick CRCA sheet outdoor type double door totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size dust and vermin proof with necessary locking arrangements, cable glands, lugs, danger notice plate, labeling of feeders, rust proof nuts/ bolts as per IS-8623, 2000Amps capacity insulated aluminum bus bar horizontal type with fixed on insulators suitable for three phase and four wire 415 volt 50 Hz AC, internal wiring, powder coated painting over primer including the following accessories fixed in the panel:-\n BI01010001010000000000000515BI0100001171
63 62 [i] Incomer: ACB, 1600 Amps, FP, 50 kA, 415 Volts, 3 Phase, 50 Hz, Fixed Electrical type with Microprocessor based O/L, S/C, E/F Release – 1 Nos\n[ii] Metering for Incomer: Digital Multifunction Meter with A, V, KW, KWH, PF, Class 1.0 with Port – 1 Nos, LT Metering CT’s, 1600 / 1A, Cast Resin Type, Class - 0.5 – 1 Set, R, Y, B, ON, OFF, Trip LED Indicating Lamps – 1 Set, Control MCB, SP, 6 Amps – As required \n[iii] Outgoing: MCCB, 400 Amps, 4P, 415 Volts, 3P, 50 Hz, Fixed Manual type adjustable with Microprocessor based O/L, S/C & E/F release – 4 Nos. \n[iv] MCCB 4 pole 500 Amps, rupturing capacity 50KA, thermal magnetic release, with adjustable type over load protection, short circuit protection - 02 Nos. BI01010001010000000000000515BI0100001172
64 63 Supply & fix APFC Panel with MD-XL capacitor, APFC relay and MCCB with all necessary accessories as incomer (Auto/ Manual option) with 200KVAR with 4 steps( 1 x 100 + 1 x 50 + 2 x 25 KVAR) complete all as specified. BI01010001010000000000000515BI0100001173 1 Each
65 64 LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 insulated aluminium bus bar horizontal type with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 2000 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:\nIncoming:\nAir circuit breaker 1600 Amps, 60 kA, MDO/EDO, 4 Pole, thermal magnetic release, with adjustable type overload protection, short circuit protection, with necessary CTs, meters and cable boxes. - 1 No.\nOutgoing:\na) MCCB 500 Amps, 50 kA, 4 Pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection,- 03 No. ( DG AMF of AC Plant ,Bldg Load Panel & 01 Spare)\nb) MCCB 400 Amps, 50 kA, 4 Pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection, - 02 No. ( 250 kva DG AMF Panel & Spare).\nc) MCCB AC 3 Phase 415 V, 50Hz 4 pole 250 A capacity 36kA with adjustable type thermal and magnetic setting relays - 02 No. (For APFC Panel-02 Nos) BI01010001010000000000000515BI0100001174 1 Each Job
66 65 d) MCCB AC 3 Phase 415 V, 50Hz 4 pole 200 A capacity 36kA with adjustable type thermal and magnetic setting relays - 02 No. (For F/F Pump House)\ne) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs \nf) LED indicating lamps with colour Red, Yellow, Blue of 05 Sets.\n BI01010001010000000000000515BI0100001175
67 66 LT Panel board (Distribution Panel) made out of CRCA sheet 2.0 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switcher gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 insulated aluminium bus bar horizontal type with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 600 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (Near Bldg LT Panel for DG Supply).\nIncoming:\nMCCB AC 3 Phase 415 V, 50Hz 4 pole 500 A capacity 50kA with adjustable type thermal and magnetic setting relays - 01 Nos\nOutgoing:\na) MCCB AC 3 Phase 415 V, 50Hz 4 pole 250 A capacity 36kA with adjustable type thermal and magnetic setting relays - 02 Nos (Spl power Supply panel)\nb) MCCB AC 3 Phase 415 V, 50Hz 4 pole 200 A capacity 25kA with adjustable type thermal and magnetic setting relays - 02 Nos (for Industrial sockets)\nc) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 100 Amp rated complete with overload protection, no-volt thermal based release.- 02 Nos. (for Bldg Light load and spare)\n BI01010001010000000000000515BI0100001176 1 Each Job
68 67 d) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, no-volt thermal based release.- 05 Nos. ( for crane and street Light load)\ne)Multifunctional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs \nf) LED indicating lamps with colour Red, Yellow, Blue - 02 Set. BI01010001010000000000000515BI0100001177
69 68 LT Panel board (For building) made out of CRCA sheet 2.0 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switcher gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 insulated aluminium bus bar horizontal type with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 800 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (for electric supply without DG load).\nIncoming:\na) MCCB 400 Amps capacity 36 kA, 4 Pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection, with necessary CTs, meters and cable boxes. - 01 No. \n BI01010001010000000000000515BI0100001178 1 Each Job
70 69 Outgoing:\na) MCCB AC 3 Phase 415 V, 50Hz 4 pole 200 A capacity 36kA with adjustable type thermal and magnetic setting relays - 03 No. ( for Compressor panel, User Load and spare)\nb) MCCB AC 3 Phase 415 V, 50Hz 4 pole 125 A capacity 36kA with adjustable type thermal and magnetic setting relays - 02 No. (For user Load with out DG & Spare)\nc)Multifunctional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs \nd) LED indicating lamps with colour Red, Yellow, Blue - 01 Sets. BI01010001010000000000000515BI0100001179
71 70 LT Panel board made out of CRCA sheet 3.15 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switcher gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 insulated aluminium bus bar horizontal type with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 800 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (LT Panel for AC plant DG Supply).\nIncoming:\na) MCCB 500 Amps, 50 kA, 4 Pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection.- 01 No. \nOutgoing:\na) MCCB AC 3 Phase 415 V, 50Hz 4 pole 315A capacity 36kA with adjustable type thermal and magnetic setting relays - 02 Nos (AC Plant and spare)\nb) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 100 Amp rated complete with overload protection, no-volt thermal based release.- 02 Nos. ( Main DB for split AC and one Spare)\nc)Multifunctional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs \nd) LED indicating lamps with colour Red, Yellow, Blue - 02 Set. BI01010001010000000000000515BI0100001180 1 Each Job
72 71 Supply & Fix Integral LED street light Luminaries 72 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing all as specified and directed.\n BI01010001010000000000000515BI0100001181 8 Each
73 72 Loop in loop out box of FRP made with IP 65 protection of thermo plastic circuit breaker boxes with metric knockouts for cable entry and exit, Combo climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc all as specified and directed. BI01010001010000000000000515BI0100001182 8 Each
74 73 Material and Labour for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip 32 x 6 mm by means of bolts and nuts check nuts and washers of galvanized iron or steel and 50 mm dia light grade GI pipe up to test point or 7.5 mtr for protection of earth electrode and GI pipe 20 mm medium grade for watering pipe with watering funnel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover of 10 mm thick with MS rod 6mm dia 150mm long reinforcement all as specified and directed and tested on completion. BI01010001010000000000000515BI0100001183 20 Each
75 74 Supply and fix Compact type Wall/pole mounted Street light Timer Panel with power coated mild steel enclosure of 12 KW,415 Volt to be fixed on pole/wall with provision of bus bar ,Power Contactor 65 Amp, MCB 63 Amp TPN ,Digital Timer Switch complete fixed with mild steel clamp, nut & bolt and including all as specified and as directed.\nMake: Havells cat no Model IHXTS09120 of or equivalent in Indoasian/ Simens. BI01010001010000000000000515BI0100001184 1 Each
76 75 LIGHTENING PROTECTION BI01010001010000000000000515BI0100001185
77 76 Earthing complete with Copper Plate Electrode 600 X 600 X 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32x6mm thick copper strip [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. BI01010001010000000000000515BI0100001186 14 Each
78 77 FIRE FIGHTING SYSTEM BI01010001010000000000000515BI0100001187
79 78 supply & fix of ductile pipe with double flanged centrifugally cast(spun) class K-9 of 150mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbow, bends reducers, taper pieces, including testing and commissioning all as specified and as directed. BI01010001010000000000000515BI0100001188 350 RM
80 79 Supply and fix MS cabinet (approx 750mm x 600mm x 450mm) to encl fire brigade inlet connections fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete all as specified and as directed. BI01010001010000000000000515BI0100001189 10 Each
81 80 Supply and fix Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 36m head, 900m LPM discharge including starter panel complete all as specified. BI01010001010000000000000515BI0100001190 1 Each
82 81 Supply and fix Gun metal fire brigade inlet connection consisting of four nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia sluice valve (1No. 150mm dia Non return valve), and 150mm dia flanges outlet complete all as specified and as directed. BI01010001010000000000000515BI0100001191 1 Each
83 82 Earthing complete with galvanized steel Plate Electrode 600 X 600 X 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to galvanized earth strip 25x4mm by means of bolts and nuts check nuts and washers of galvanized iron or steel all as specified Electrical Plate No. 3 of SSR Part – I, including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with C! cover of 10mm thick with MS rod 6mm dia 150mm long reinforcement, watering funnel with 15mm dia light grade for watering and for protection of earth electrode 32mm dia GI pipe all as specified. BI01010001010000000000000515BI0100001192 1 Each
84 83 Supply and install Fire Extinguisher CO2 Type light weight squeeze grip type confirming to IS 15683 of capacity 3kg all as specified.\n BI01010001010000000000000515BI0100001193 8 Each
85 84 Supply and install Fire Extinguisher Dry chemical, powder(ABC) type confirming to IS 15683 of capacity 3kg all as specified.\n BI01010001010000000000000515BI0100001194 8 Each
86 85 Supply and install MS rectangular fire bucket stand with canopy for accommodate 4 Nos fire buckets duly painted in red colour all as specified. BI01010001010000000000000515BI0100001195 2 Each
87 86 Supply and fix fire buckets for sand and water of capacity 9 Liter duly painted in red colour all as specified. BI01010001010000000000000515BI0100001196 8 Each
88 87 FIRE ALARAM SYSTEM BI01010001010000000000000515BI0100001197
89 88 Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and directed. BI01010001010000000000000515BI0100001198 350 RM
90 89 Supply and fix GI Cable tray with cover for fixing XLPE cable from duty room to terrace for siren and at various places to accommodate the cables for MCPs, Panel etc of size not less than 75 x 38 mm with necessary bends, angles, supports for fixing, etc all as specified and directed. BI01010001010000000000000515BI0100001199 30 RM
91 90 Supply, fix and testing of Beam Master detector with Transmitter and receiver including power supply units & Module complete all as specified. BI01010001010000000000000515BI0100001200 11 Each
92 91 SPLIT AIR CONDITIONING BI01010001010000000000000515BI0100001201
93 92 Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ionizer and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2.0 TR all as specified and directed. \n BI01010001010000000000000515BI0100001202 9 Each
94 93 Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ionizer and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR all as specified and directed. \n BI01010001010000000000000515BI0100001203 17 Each
95 94 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA. BI01010001010000000000000515BI0100001204 17 Each
96 95 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA BI01010001010000000000000515BI0100001205 9 Each
97 96 S & F Sheet metal Enclosure with socket Plug Top and MCBS Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified and directed. BI01010001010000000000000515BI0100001206 26 Each
98 97 AIR COMPRESSOR BI01010001010000000000000515BI0100001207
99 98 Supply and fix HP Air Compressor of output 220 Kgf/Cmsq with oil and moisture separator , Air drier unit and Dehumidifier with air bottles complete all as specified and directed by Engr-In-charge of following specifications . Make: Bauer Kompressoren and its equivalent\nCompressor block specification:-\n(i) Working medium : Air\n(ii) Final Safety Valve set pressure : 280 bar\n(iii) Working Pressure : 220 bar adjustable by final pressure sensor acc., Hysteresis adjustable\n(iv) Capacity : 3500 lpm (210 M3/hr)\n(v) Compressor Speed : 1180 rpm\n(vi) No. of compression stages : 4\n(vii) Power consumption at working pressure :68KW \n(viii) Drive : V - Belt drive\nPrime Mover Specifications : \nType : Non flame proof, 3 phase electric (TEFC) motor with insulation class 'F' with temperature rise limited to B, Foot Mounted, S1 duty\nRating : 75 KW\nSpeed : 1450 rpm\nEnclosure/Degree of Protection : IP55\nOperating Voltage & Freq : 415 V, 50 Hz BI01010001010000000000000515BI0100001208 1 EACH
100 99 Supply and fix High Pressure (220 Kgf/Cmsq) seamless stainless steel Air line of 18 mm outer dia with dis-mountable type suitable for distribution of compressed air in workshop as per user requirement including all fittings such as union, elbow, tee ,male connector etc all as specified and directed. BI01010001010000000000000515BI0100001209 150 RM
101 100 Supply and fix Low Pressure (40 Kgf/Cmsq) seamless stainless steel Air line of 16 mm outer dia with dis-mountable type suitable for distribution of compressed air in workshop as per user requirement including all fittings such as union, elbow, tee, male connector etc all as specified and directed. BI01010001010000000000000515BI0100001210 150 RM
102 101 Supply and fix High Pressure (220 Kgf/Cmsq) control valves suitable for 18 mm outer dia pipe stainless steel pipe all as specified and directed. BI01010001010000000000000515BI0100001211 5 Each
103 102 Supply and fix Low Pressure (40 Kgf/Cmsq) control valves suitable for 16 mm outer dia pipe stainless steel pipe all as specified and directed. BI01010001010000000000000515BI0100001212 5 Each
104 103 Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. for supporting the compressed air pipe lines. BI01010001010000000000000515BI0100001213 2 Qtl
105 104 AIR CURTAINS BI01010001010000000000000515BI0100001214
106 105 Supply, install, commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, three phase 440 V, 50 Hz, of size 58" x 96" (2 Curtains at each door to match the door opening) all as specified and directed. BI01010001010000000000000515BI0100001215 2 Each
107 106 ARBORICULTURE BI01010001010000000000000515BI0100001216
108 107 Supply, plantation and developing of Carpet Grass by piece turfing including necessary earthwork excavation to a depth of 30cm in any type of soil, removing the roots and vegetation and filling of good earth, cow dung and watering etc. and applying soil pesticide, transplanting of Grass, planting, routing etc. including cost of manuring the soil, pesticides, grass, manure etc. complete all as specified. BI01010001010000000000000515BI0100001217 689 Sqm
109 108 Supply only approved loose soil best quality for plantation BI01010001010000000000000515BI0100001218 137.8 Cum
110 109 Supply only approved manure (cow dung) best quality BI01010001010000000000000515BI0100001219 137.8 Cum
111 110 Supply only approved vermi compost best quality BI01010001010000000000000515BI0100001220 100 Bag of 50Kg
112 111 Supply, plantation and developing of Royal Palm plant [height of plant not less than 1.5 meter above ground level and of age 30 Days] with proportional girth, evergreen and shady species including preparation of ground up to 600mm deep and of size 600 X 600mm and filling of good earth [3 Parts], Cow dung and Vermi-Compost [1 Part] and watering etc. complete all as specified. BI01010001010000000000000515BI0100001221 100 Each
113 112 Supply, plantation and developing of Foxtail Palm plant [height of plant not less than 2 meter above ground level and of age 30 Days] with proportional girth, evergreen and shady species including preparation of ground up to 600mm deep and of size 600 X 600mm and filling of good earth [3 Parts], Cow dung and Vermi-Compost [1 Part] and watering etc. complete all as specified. BI01010001010000000000000515BI0100001222 100 Each
114 113 EOT CRANE BI01010001010000000000000515BI0100001223
115 114 Supply, Install, Test and Commissioning of Electrically operated over Head Travelling [EOT] Crane of 3.0 Ton Capacity complete and having of 12 meters span [approximate] with long travel distance of 43 meters with clear hook height of 5.0 meters from floor level, double box girder type with necessary steel supporting structure electric motor with micro motion control with VVVF drive and shall be operated by means of push button pendent unit from the floor and control panel and operated with pendent control moveable independent of crab position including provision of steel gantry rails for long travel for complete length and provision of down shop Lead[DSL] and shrouded bus bar system complete all as specified.\na) Hoist Speed 2.0 m/min\nb) Hoist Creep 0.2 m/min\nc) C.T Speed 10.0 m/min\nd) C.T Creep 1 m/min\ne) L.T Speed 12.0 m/min\nf) L.T Creep 1.2 m/min\ng) Hook Height 5.0 m BI01010001010000000000000515BI0100001224 1 Each Job
116 115 Supply, Install, Test and Commissioning of Electrically operated over Head Travelling [EOT] Crane of 3.0 Ton Capacity complete and having of 18 meters span [approximate] with long travel distance of 26.7 meters with clear hook height of 5.0 meters from floor level, double box girder type with necessary steel supporting structure electric motor with micro motion control with VVVF drive and shall be operated by means of push button pendent unit from the floor and control panel and operated with pendent control moveable independent of crab position including provision of steel gantry rails for long travel for complete length and provision of down shop Lead[DSL] and shrouded bus bar system complete all as specified.\na) Hoist Speed 2.0 m/min\nb) Hoist Creep 0.2 m/min\nc) C.T Speed 10.0 m/min\nd) C.T Creep 1 m/min\ne) L.T Speed 12.0 m/min\nf) L.T Creep 1.2 m/min\ng) Hook Height 5.0 m BI01010001010000000000000515BI0100001225 1 Each Job
117 116 Supply, erection, testing & commissioning of crane hand operated OH complete with span 8.0 meter, lift (hook height) 5.0 meter & 6.8 meter traverse (bay length) including gravity rail system long travel wheels and the chain pulley block of capacity 2 Ton with following specifications : (for compressor room)\na) Non-ferrous parts like chain wheels, chain guides, ratchet wheel and stripping fork.\nb) Eliminate spark generation possibilities during of mating parts.\nc) Tested for 50% overload with grade 80 load chain and zinc plated hand chain with double ball bearing supported load wheel.\nd) Precision machine case hardened alloy steel gears, noise less operation with anti-corrosive powder coated zinc plated parts and rust protection. BI01010001010000000000000515BI0100001226 1 Each Job
118 117 Supply, erection, testing & commissioning of crane hand operated OH complete with span 3.0 meter, lift (hook height) 5.0 meter & 8.2 meter traverse (bay length) including gravity rail system long travel wheels and the chain pulley block of capacity 2 Ton with following specifications : (for Air Bottle Room)\na) Non-ferrous parts like chain wheels, chain guides, ratchet wheel and stripping fork.\nb) Eliminate spark generation possibilities during of mating parts.\nc) Tested for 50% overload with grade 80 load chain and zinc plated hand chain with double ball bearing supported load wheel.\nd) Precision machine case hardened alloy steel gears, noise less operation with anti-corrosive powder coated zinc plated parts and rust protection. BI01010001010000000000000515BI0100001227 1 Each Job
119 118 Supply, erection, testing & commissioning of crane hand operated OH complete with span 8.0 meter, lift (hook height) 5.0 meter & 30.2 meter traverse (bay length) including gravity rail system long travel wheels and the chain pulley block of capacity 2 Ton with following specifications : (for Sub Assistant Hall)\na) Non-ferrous parts like chain wheels, chain guides, ratchet wheel and stripping fork.\nb) Eliminate spark generation possibilities during of mating parts.\nc) Tested for 50% overload with grade 80 load chain and zinc plated hand chain with double ball bearing supported load wheel.\nd) Precision machine case hardened alloy steel gears, noise less operation with anti-corrosive powder coated zinc plated parts and rust protection. BI01010001010000000000000515BI0100001228 1 Each Job
120 119 Supply and fix jib crane (Circular Crane) hand operated OH complete with radius of 2.0 meter, hook height 2.5m and capacity 1 Ton complete all as specified (for Electric System Room)\n\nNote for Serial Item No. 112 to 117 The quoted rate is deemed to be inclusive of electrical connection using suitable size copper conductor multistranded PVC insulated PVC sheathed armoured cable from the main switch to the DSL assembly. The span and clear long travel and clear height above girder position shall be as shown on drawing and as per finished dimensions of building at site. Tenderer shall visit the site and ascertain the exact span and the dimensions before quoting the tender. All movements shall be operated by means of push buttons free from floor level with protective panel independently with inter locking arrangement to avoid accident due to manual/dual operation, if accidentally crane is operated from ground. Flame Proof Push button unit shall be deemed to be included in the unit rate quoted. The cable control shall have push button for stop at all motions at hold the locations. Rail and gantry girders shall be provided by the contractor. BI01010001010000000000000515BI0100001229 1 Each Job
121 120 DG SET BI01010001010000000000000515BI0100001230
122 121 Silent engine generating set with acoustic enclosure as per CPCB norms 415 volts 320 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:-\n(i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design.\n(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.\n(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test.\n(A) Alternator :- Standard design alternator rated at 320 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722.\ni) Insulation class - 'H‘\nii) Temperature rise Class - 'H‘\niii) Excitation : Self Excited\n BI01010001010000000000000515BI0100001231 1 Each Set
123 122 iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5%\nv) Frequency regulation +/- 1%\n(B) Diesel Engine: - Adequate capacity of Diesel engine as approved by GE basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under\ni) Fly wheel with housing.\nii) Cooling system :- Moulded radiator with fan & belts\niii) Cooling Water pump : - Centrifugal type belt driven\niv) Exhaust System :- Exhaust System complete with exhaust piping of suitable size with MS pipe light grade up to & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold, Silencer : Residual type Bellows\nv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses.\nvi) Lubricating oil System : Lubricating oil filter Lubricating oil pump BI01010001010000000000000515BI0100001232
124 123 vii) Air Intake System :Air intake Manifold\nAir cleaner dry type\nviii) Governor :- Electronic Governor\nix) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator\nx) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, Lubricating oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel\nxi) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant Temperature indicator, Battery volt display.\nxii) Safety Controls : - Engine low lubricating oil pressure high water Temperature and over speeding of engine.\nxiii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling.\nxiv) Accessories :- AVM Pads built in enclosure and for entire unit on platform.\nxv) Base Frame : - Should be provided as OEM norms BI01010001010000000000000515BI0100001233
125 124 xvi) Fuel Tank :- Additional Fuel Tank of capacity to suit Daily service fuel tank made out of 3mm thick (10G) HR sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the acoustic enclosure.\nxvi) MS pipe line to and from the fuel tank to the DG Set \nC) AMF Panel :- Factory made outdoor type control cubical made out of CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 320 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole ACB/MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc.\na) Annunciation with indication lamps for :\n (i) Low Lubricating oil pressure.\n (ii) High Water Temperature.\n (iii) Engine over speed.\n (iv) Battery low voltage\nControls :-\na) Load on Indication\nb) Load off indication\nc) Engine start push button BI01010001010000000000000515BI0100001234
126 125 d) Engine stop push button\ne) Fault accept / reset push button\nf) Battery Charger :\n (i) Transformer\n (ii) Rectifier\n (iii) Resistance\n (iv) DC Volt meter\n (v) DC Ammeter\n (vi) Charger rate selector switch\nD) acoustic Enclosure:- Manufactured by OEM suitable for 320 KVA DG Set\n (i) NAL approved as per CPCB\n(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board\n(iii) The generating set batteries and control panel should be inside the enclosure.\n(iv) Construction Details/specification are as follows:\na) Outer body :- CRCA Sheet of 1.6mm thick\nb) Doors :- CRCA sheet of 1.6 mm thick\nc) Sound Insulation :- As per OEM Norms\nv) The acoustic should be composite in construction and fully assembled integral unit\nvi) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form\nvii) The DG Set should be provided with external Emergency stop push button\n BI01010001010000000000000515BI0100001235
127 126 viii) The enclosure should be suitably illuminated by LED Lamp fittings.\nix) The noise level should be 75 dba at 1m under free field conditions.\nx) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade\nE) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 2. 4 x 0.8 m for placing of DG Set complete all as specified and directed. BI01010001010000000000000515BI0100001236
128 127 Silent engine generating set with acoustic enclosure as per CPCB norms 415 volts 250 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:-\n(i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design.\n(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.\n(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test\n(A) Alternator :- Standard design alternator rated at 250 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722\ni) Insulation class - 'H‘\nii) Temperature rise Class - 'H‘\niii) Excitation : Self Excited\n BI01010001010000000000000515BI0100001237 1 Each Set
129 128 iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5%\nv) Frequency regulation +/- 1%\n(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under\ni)Fly wheel with housing\nii) Cooling system :- Moulded radiator with fan & belts\niii) Cooling Water pump : - Centrifugal type belt driven\niv) Exhaust System :- Exhaust System complete with exhaust piping of suitable size with MS pipe light grade up to & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure.\nExhaust gas turbo charger type. Exhaust manifold\nSilencer : Residual type Bellows BI01010001010000000000000515BI0100001238
130 129 v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses.\nvi) Lubricating oil System :Lubricating oil filter Lubricating oil pump\nvii) Air Intake System : Air intake Manifold Air cleaner dry type\nvii) Governor :- Electronic Governor\nviii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator\nix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch\nHandling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, Lubricating oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel\nx) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant Temperature indicator, Battery volt display.\nxi) Safety Controls : - Engine low lube oil pressure high water Temperature and over speeding of engine.\n BI01010001010000000000000515BI0100001239
131 130 xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling\nxiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform.\nxiv) Base Frame : - Should be provided as OEM norms\nxv) Fuel Tank :- Fuel Tank of suitable capacity to suit Daily service fuel tank made out of 3mm thick (10G) HR sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base in side the acoustic enclosure.\nxvi) MS pipe line to and from the fuel tank to the DG Set \nC) AMF Panel :- Factory made outdoor type control cubical made out of CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 250 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole ACB/MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc\na) Annunciation with indication lamps for :\n (i) Low Lubricating oil pressure.\n (ii) High Water Temperature.\n BI01010001010000000000000515BI0100001240
132 131 (iii) Engine over speed.\n (iv) Battery low voltage\nControls :-\na) Load on Indication\nb) Load off indication\nc) Engine start push button\nd) Engine stop push button\ne) Fault accept / reset push button\nf) Battery Charger :\n (i) Transformer\n (ii) Rectifier\n (iii) Resistance\n (iv) DC Volt meter\n (v) DC Ammeter\n (vi) Charger rate selector switch\nD) acoustic Enclosure:- Manufactured by OEM suitable for 250 KVA DG Set\n (i) NAL approved as per CPCB\n(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board\n(iii) The generating set batteries and control panel should be inside the enclosure.\n(iv) Construction Details/specification are as follows:\na) Outer body :- CRCA Sheet of 1.6mm thick\nb) Doors :- CRCA sheet of 1.6 mm thick\nc) Sound Insulation :- As per OEM Norms\n BI01010001010000000000000515BI0100001241
133 132 v) The acoustic should be composite in construction and fully assembled integral unit\nvi) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form\nvii) The DG Set should be provided with external Emergency stop push button\nix) The enclosure should be suitably illuminated by LED Lamp fittings.\nx) The noise level should be 75 dba at 1m under free field conditions.\nxi) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade.\nE) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 2. 4 x 0.8 m for placing of DG Set complete all as specified and directed. BI01010001010000000000000515BI0100001242
134 133 Material and Labour for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip 32 x 6 mm by means of bolts and nuts check nuts and washers of galvanized iron or steel and 50 mm dia light grade GI pipe up to test point or 7.5 mtr for protection of earth electrode and GI pipe 20 mm medium grade for watering pipe with watering funnel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover of 10 mm thick with MS rod 6mm dia 150mm long reinforcement all as specified and directed and tested on completion. BI01010001010000000000000515BI0100001243 12 Each Set
135 134 POWER SUPPLY BI01010001010000000000000515BI0100001244
136 135 Supply, installation, commissioning and testing of 15 KVA Static DC Power Supply 415 Volt A/C 50 cycle input & 27 VDC +/-1% tolerance output with Programmable Controller for Output Voltage with Password Protection & Enclosure Protection IP 55 with following specification given here in below :-\nRated power @ 0.8 pf lag : 27V DC, 15 KVA \nINPUT\nVoltage - Nominal : 400V\n Range : 340 - 480V Ac\nFrequency- Nominal : 50Hz\n Range : 47-53Hz\n Phase : Three\nAC to DC Efficiency : 92%\nRectifier\nTechnology: 12 Pulse Rectifier SCR based fully controlled\nPower walk in: 10 to 15 secs\nTHDi (input current Harmonic Distortion ): < 10% at rated load \n \nInput power Factor > 0.92lag\nGalvanic isolation: Inbuilt Galvanic Isolation\nOUT PUT\nVoltage - Nominal: 27VDC (Programmable)\n Regulation: +/-1% \nOverload : 110% for 30 min, 150% for 10sec \n Protections: Input Over/under voltage, Input Phase fail, overload, DC over/under voltage, snubber circuits for power devices, over temperature, fuse for semi conductor devices BI01010001010000000000000515BI0100001245 1 EACH
137 136 Indications: Mains ON, DC ON, Mains Over/Under Voltage, Phase Fail, DC over/under voltage, overload, overheat\nRemote Alarm : Potential free contacts for input fault & output trip\nMetering: 16 x 2 LCD for I/p & O/p Volts, DC Volts,& output current \nGENERAL\nOperating Temperature : 0 to 45 Deg C (50 Deg C Peak)\nStorage Temperature : -20 to 45 deg C \nRelative Humidity : 95% non condensing\nCooling : Forced Air using localized cooling technique with multiple fractional HP fans\nPanel : Welded structure MS Covers 2mm and frame 3mm thick\nEnclosure protection: IP 55\nCable Entry : Front Bottom BI01010001010000000000000515BI0100001246
138 137 Supply, installation, commissioning and testing static frequency converter 415 Volt A/C 50 cycle input & output voltage 40 Volts + 1% tolerance output, 1000Hz, 3 phase, 5 KVA with Programmable Controller for output voltage & Frequency with password protection, Enclosure Protection IP-55 complete as per specification given here in below\nRated power @ 0.8 pf lag: 5 KVA \nINPUT\nVoltage - Nominal : 400V AC\n Range : 340 to 460 V AC\nFrequency- Nominal : 50Hz\n Range : 47-53Hz\n Phase : Three\nAC to AC Efficiency : 92%\nRectifier\nTechnology: 12 Pulse Rectifier SCR based fully controlled\nPower walk in: 10 to 15 secs\nTHDi (input current Harmonic Distortion ): < 10% at rated load \nInput power Factor > 0.92lag\nGalvanic isolation: Inbuilt Galvanic Isolation.\nOUT PUT\nVoltage - Nominal: 40 V AC ( P-P Programmable)\n Regulation: 1% \nFrequency - Nominal : 1000Hz ( Programmable)\n Stability : 0.05% \nPhase : Three Phase\nWaveform : Sine Wave BI01010001010000000000000515BI0100001247 1 EACH
139 138 Total Harmonic Distortion : < 2% on linear load\nTransient Response: less than +/-8% for 100% step loads \nRecovery Time: less than 25milli secs to reach within +/-1% of nominal value\nLoad power factor range : 0.8 lag to unity within KW rating\nOverload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. \nProtections: Input over/under voltage, Input Phase fail, overload, Output over/under voltage, snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuse less tripping for output short circuit\nIndications: Input ON, Output ON, Input abnormal, Output over/Under voltage, overload, overheat\nRemote Alarm " Potential free contacts for input fault & output trip\nMetering: 16x2 LCD panel to measure the following: AC input voltage, output voltage, load percentage, input & output frequency.\nGENERAL\nOperating Temperature : 0 to 45 Deg C (50 Deg C Peak)\nStorage Temperature : -20 to 45 deg C \nRelative Humidity : 95% non condensing\nCooling : Forced Air using localized cooling technique with multiple fractional HP fans\nPanel : Welded structure MS Covers 2mm and frame 3mm thick\nEnclosure protection: IP 55\nCable Entry : Front Bottom BI01010001010000000000000515BI0100001248
140 139 Supply, installation, commissioning and testing Uninterrupted Power Supply System 415 Volt A/C 50 cycle input & output voltage 220Volts + 0.5% tolerance output, 50Hz, 3 phase, 15KVA with Programmable Controller for output voltage with password protection, Enclosure Protection IP-55 along with SMF Batteries for 30 minutes back up complete as per specification given here in below :-\nRated power @ 0.8 pf lag: 15KVA \nINPUT\nVoltage - Nominal : 400V AC\n Range : 340 to 460 V AC\nFrequency- Nominal : 50Hz\n Range : 47-53Hz\n Phase : Three\nAC to AC Efficiency : 92%\nRectifier\nTechnology: 12 Pulse Rectifier SCR based fully controlled\nPower walk in: 10 to 15 secs\nTHDi (input current Harmonic Distortion ): < 10% at rated load \nInput power Factor > 0.92lag\nGalvanic isolation: Inbuilt Galvanic Isolation.\nOUT PUT\nVoltage - Nominal: 220V AC ( Programmable)\n Regulation: 1% \nFrequency - Nominal : 50Hz ( Programmable)\n Stability : 0.05% \nPhase : Three Phase BI01010001010000000000000515BI0100001249 1 EACH
141 140 Waveform : Sine Wave\nTotal Harmonic Distortion : < 2% on linear load\nTransient Response: less than +/-8% for 100% step loads \nRecovery Time: less than 25milli secs to reach within +/-1% of nominal value\nLoad power factor range : 0.8 lag to unity within KW rating\nOverload Protection: 120% for 30 min., 150% for 1min, 200% for 10 cycles. \nProtections: Input over/under voltage, Input Phase fail, overload, Output over/under voltage, snubber circuits for power devices, over temperature, fuses for semi conductor devices, high speed electronic fuse less tripping for output short circuit.\nIndications: Input ON, Output ON, Input abnormal, Output over/Under voltage, overload, overheat\nRemote Alarm " Potential free contacts for input fault & output trip\nMetering: 16x2 LCD panel to measure the following: AC input voltage, output voltage, load percentage, input & output frequency\nGENERAL\nOperating Temperature : 0 to 45 Deg C (50 Deg C Peak)\nStorage Temperature : -20 to 45 deg C \nRelative Humidity : 95% non condensing\nCooling : Forced Air using localized cooling technique with multiple fractional HP fans\nPanel : Welded structure MS Covers 2mm and frame 3mm thick\nCable Entry : Front Bottom BI01010001010000000000000515BI0100001250
142 141 Supply, Installation & Commissioning of Static Voltage Regulator 125KVA , Input Voltage 415V AC, 3 Ph , 50 Hz & Output Voltage 380V +/- 1%, 50Hz, 3 Ph. comprising of:-\nRated power @ 0.8 pf lag: 125KVA with Harmonic Filters & Surge Suppressor & Voltage Correction rate 60V/sec.\nINPUT\nVoltage - Nominal : 400V AC\n Range : 340 to 470 V AC\nFrequency- Nominal : 50Hz\n Range : 47-53Hz\n Phase : Three\nAC to AC Efficiency : 92%\nRectifier\nTechnology: 12 Pulse Rectifier SCR based fully controlled\nPower walk in: 10 to 15 secs\nTHDi (input current Harmonic Distortion ): < 10% at rated load \nInput power Factor > 0.92lag\nGalvanic isolation: Inbuilt Galvanic Isolation.\nOUT PUT\nVoltage - Nominal: 380V AC \n Regulation: 1% \n Stability : +/-3% \nVoltage Correction Rate: 60 V/Sec\nPhase : Three Phase\nWaveform : Sine Wave\nTotal Harmonic Distortion : < 2% on linear load BI01010001010000000000000515BI0100001251 1 EACH
143 142 Transient Response: Recovery to =/-10% within 10 cycles for input variations 340 - 470 & load variations from 0 to 100% \nRecovery Time: less than 25milli secs to reach within +/-1% of nominal value\nLoad power factor range : 0.8 lag to unity within KW rating\nOverload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. \nProtections: Input circuit breaker with magnetic & Thermal Strip, Fast acting fuses and R-C Surge Suppressors for SCR protection, HRC fuses & Harmonic Filter at output. Input & Output Protection through MCCB/HRC Fuses & Isolators.\nMetering: Digital Meters for AC Input Voltage & AC Output Voltage, AC Ammeter for Output Current with selector switch & Frequency Meter at Input & Output.\nIndications: Input ON, Output ON, AC under/Over Voltage, SCR Fuse failure, SCR Over temperature trip, Fan Failure \nRFI: Suitable Radio Frequency Interference suppression devices shall be provided on the input side to suppress RFI.\nGENERAL\nOperating Temperature : -10 to +55 deg C \nStorage Temperature : -20 to 4+60 deg C `\nRelative Humidity : 95% non condensing\nCooling : Forced Air cooled by employing spot cooling by using multiple fans.\nPanel : Welded structure MS Covers 2mm and frame 3mm thick\nEnclosure Protection: IP 55\nCable Entry : Front Bottom BI01010001010000000000000515BI0100001252
144 143 Supply, Installation & Commissioning of Static Voltage Regulator 200KVA , Input Voltage 415V AC, 3 Ph , 50 Hz & Output Voltage 380V =/- 1%, 50Hz, 3 Ph. comprising of:-\nRated power @ 0.8 pf lag: 200KVA with Harmonic Filters & Surge Suppressor & Voltage Correction rate 60V/sec.\nINPUT\nVoltage - Nominal : 400V AC\n Range : 340 to 470 V AC\nFrequency- Nominal : 50Hz\n Range : 47-53Hz\n Phase : Three\nAC to AC Efficiency : 92%\nRectifier\nTechnology: 12 Pulse Rectifier SCR based fully controlled\nPower walk in: 10 to 15 secs\nTHDi (input current Harmonic Distortion ): < 10% at rated load \n \nInput power Factor > 0.92lag\nGalvanic isolation: Inbuilt Galvanic Isolation.\nOUT PUT\nVoltage - Nominal: 220V AC \n Regulation: 1% \n Stability : +/-3% \nVoltage Correction Rate: 60 V/Sec\nPhase : Three Phase\nWaveform : Sine Wave\nTotal Harmonic Distortion : < 2% on linear load BI01010001010000000000000515BI0100001253 1 EACH
145 144 Transient Response: Recovery to =/-10% within 10 cycles for input variations 340 - 470 & load variations from 0 to 100% \nRecovery Time: less than 25milli secs to reach within +/-1% of nominal value\nLoad power factor range : 0.8 lag to unity within KW rating\nOverload Protection: 120% for 30 min., 150% for1min, 200% for 10 cycles. \nProtections: Input circuit breaker with magnetic & Thermal Strip, Fast acting fuses and R-C Surge Suppressors for SCR protection, HRC fuses & Harmonic Filter at output. Input & Output Protection through MCCB/HRC Fuses & Isolators.\nMetering: Digital Meters for AC Input Voltage & AC Output Voltage, AC Ammeter for Output Current with selector switch & Frequency Meter at Input & Output.\nIndications: Input ON, Output ON, AC under/Over Voltage, SCR Fuse Failure, SCR Over temperature trip, Fan Failure \nRFI: Suitable Radio Frequency Interference suppression devices shall be provided on the input side to suppress RFI.\n GENERAL\nOperating Temperature : -10 to +55 deg C \nStorage Temperature : -20 to 4+60 deg C \nRelative Humidity : 95% non condensing\nCooling : Forced Air cooled by employing spot cooling by using multiple fans.\nPanel : Welded structure MS Covers 2mm and frame 3mm thick\nEnclosure Protection: IP 55\nCable Entry : Front Bottom BI01010001010000000000000515BI0100001254
146 145 Supply and fix Wall/Floor mounted Mains Distribution Panel made out of 2mm thick CRCA sheet indoor type with including following:. \ninput Side :\n 1000A MCCB, 35KA, 4P, 415V "C" Curve, Copper Bus bar mounted on insulators suitable for 415V,50Hz, 3Ph, 4 wire, 1000A, 15 inch long with 6 tap off points, with Voltmeter & Ammeter to display Input voltage.\n Output\n(i) 16A, TPN MCB,415V, 10KA -02 No.\n(ii) 26A, TPN MCB,415V, 10KA -01 No.\n(iii) 250A MCCB, 4P,415V, 35KA "C" Curve -01No.\n(iv) 750A MCCB, 4P,415V, 35KA "C" Curve -01No. BI01010001010000000000000515BI0100001255 1 EACH
147 146 Supply & Fixing wall mounted Output distribution panel made out of 2mm thick CRCA sheet indoor type with VIF meters to display output suitable to accommodate: (i) 160A,MCCB, 4P, 25 KA"C" Curve 1No. on Input side & 1' Copper Bus bar mounted on insulators with 4 tap off points suitable for 27V DC, 2 wire, 300A on output side (ii) 125A,MCCB, 4P, 25 KA, "C" Curve 1No.on Input side & 1' copper Bus bar mounted on insulators with 4 tap off points suitable for 40V, 1Ph, 1KHz, 4 wire, 150A on output side {iii] 200A MCCB, 4P, 25KA, "C" Curve 1No. on input side & 1" copper bus bar mounted on insulators with 4 tap off points suitable for 380V, 3P., 4wire, 50Hz, 20A/Ph. BI01010001010000000000000515BI0100001256 1 EACH
148 147 Supply & Fixing wall mounted Output distribution panel made out of 2mm thick CRCA sheet indoor type with VIF meters to display output suitable to accommodate: (i) 63A DP,MCB,10KA 1No. on Input side & 1' Copper Bus bar mounted on insulators with 4 tap off points suitable for 220V AC, 2 wire, 80A on output side (ii) 500A,MCCB, 4P, 35 KA, "C" Curve 1No.on Input side & 1' copper Bus bar mounted on insulators with 4 tap off points suitable for 220V, 1Ph, 50Hz, 2 wire, 1000A on output side. \n BI01010001010000000000000515BI0100001257 1 EACH
149 148 Supply & Fixing wall mounted Sub Output distribution panel made out of 2mm thick CRCA sheet indoor type with VIF meters to display output suitable to accommodate: (i) 63A,TPN, MCB, 10KA 1No. on Input side & 9" Copper Bus bar mounted on insulators with 6 tap off points suitable for 27V DC, 2 wire, 120A on output side (ii) 63A,TPN MCB, 4P,10KA 1No.on Input side & 6" copper Bus bar mounted on insulators with 4 tap off points suitable for 40V, 1Ph, 1KHz, 4 wire, 50A/Ph on output side {iii] 63A , TPN MCB, 10KA, 1No. on input side & 9" copper bus bar mounted on insulators with 4 tap off points suitable for 380V, 3P., 4wire, 50Hz, 60A/Ph.{iv} 250A MCCB, 4P, 35KA, "C" Curve 1No. on Input Side & 1' long copper bus bar mounted on insulators with 8 tap off points suitable for 220V, 1Ph, 2 wire, 50Hz, 550A{v) 80A DP MCB, 10KA,1No. on input side & 6" copper bus bar mounted on insulators with 3 tap off points suitable for 220V,1Ph, 2 wire, 50Hz,80A BI01010001010000000000000515BI0100001258 1 EACH
150 149 Supply & Fixing wall mounted Sub Output distribution panel made out of 2mm thick CRCA sheet indoor type with VIF meters to display output suitable to accommodate: \n(i) 50A,DP, MCB, 10KA 1No. on Input side & 6" Copper Bus bar mounted on insulators with 2 tap off points suitable for 27V DC, 2 wire, 60A on output side \n(ii) 32A,TPN MCB,10KA 1No.on Input side & 6" copper Bus bar mounted on insulators with 4 tap off points suitable for 40V, 1Ph, 1KHz, 4 wire, 30A/Ph on output side \n{iii] 32A , TPN MCB, 10KA, 1No. on input side & 6" copper bus bar mounted on insulators with 2 tap off points suitable for 380V, 3P., 4wire, 50Hz, 60A/Ph.\n{iv} 63A, TPN MCB, 10KA, 1No. on Input Side & 9" long copper bus bar mounted on insulators with 4 tap off points suitable for 220V, 1Ph, 2 wire, 50Hz, 120A{v} 50A DP MCB, 10KA,1No. on input side & 6" copper bus bar mounted on insulators with 2 tap off points suitable for 220V,1Ph, 2 wire, 50Hz,50A BI01010001010000000000000515BI0100001259 1 EACH
151 150 Supply & Fixing wall mounted Sub Output distribution panel made out of 2mm thick CRCA sheet indoor type with VIF meters to display output suitable to accommodate: (i) 32A,DP, MCB, 10KA 1No. on Input side & 6" Copper Bus bar mounted on insulators with 2 tap off points suitable for 27V DC, 2 wire, 30A on output side (ii) 32A,TPN MCB,10KA 1No.on Input side & 6" copper Bus bar mounted on insulators with 4 tap off points suitable for 40V, 1Ph, 1KHz, 4 wire, 30A/Ph on output side {iii] 32A , TPN MCB, 10KA, 1No. on input side & 6" copper bus bar mounted on insulators with 2 tap off points suitable for 380V, 3P., 4wire, 50Hz, 60A/Ph.{iv} 63A, TPN MCB, 10KA, 1No. on Input Side & 9" long copper bus bar mounted on insulators with 4 tap off points suitable for 220V, 1Ph, 2 wire, 50Hz, 120A{v} 50A DP MCB, 10KA,1No. on input side & 6" copper bus bar mounted on insulators with 2 tap off points suitable for 220V,1Ph, 2 wire, 50Hz,50A BI01010001010000000000000515BI0100001260 1 EACH
152 151 Supply & Fixing wall mounted Sub Output distribution panel made out of 2mm thick CRCA sheet indoor type with VIF meters to display output suitable to accommodate: \n(i) 32A,DP, MCB, 10KA 1No. on Input side & 6" Copper Bus bar mounted on insulators with 2 tap off points suitable for 27V DC, 2 wire, 30A on output side \n{ii] 32A , TPN MCB, 10KA, 1No. on input side & 6" copper bus bar mounted on insulators with 2 tap off points suitable for 380V, 3P., 4wire, 50Hz, 60A/Ph.{iii} 63A, TPN MCB, 10KA, 1No. on Input Side & 9" long copper bus bar mounted on insulators with 4 tap off points suitable for 220V, 1Ph, 2 wire, 50Hz, 120A\n BI01010001010000000000000515BI0100001261 1 EACH
153 152 Supply & Fixing wall mounted Sub Output distribution panel made out of 2mm thick CRCA sheet indoor type with VIF meters to display output suitable to accommodate: \n(i) 32A,DP, MCB, 10KA 1No. on Input side & 6" Copper Bus bar mounted on insulators with 2 tap off points suitable for 27V DC, 2 wire, 30A on output side \n(ii) 32A,TPN MCB,10KA 1No.on Input side & 6" copper Bus bar mounted on insulators with 4 tap off points suitable for 40V, 1Ph, 1KHz, 4 wire, 30A/Ph on output side \n{iii] 32A , TPN MCB, 10KA, 1No. on input side & 6" copper bus bar mounted on insulators with 2 tap off points suitable for 380V, 3P., 4wire, 50Hz, 60A/Ph.\n{iv} 160A, MCCB, 10KA, 1No. on Input Side &1' long copper bus bar mounted on insulators with 4 tap off points suitable for 220V, 1Ph, 2 wire, 50Hz, 350A{v} 32A DP MCB, 10KA,1No. on input side & 6" copper bus bar mounted on insulators with 2 tap off points suitable for 220V,1Ph, 2 wire, 50Hz,30A\n BI01010001010000000000000515BI0100001262 1 EACH
154 153 Supply & Fixing wall mounted Sub Output distribution panel made out of 2mm thick CRCA sheet indoor type with VIF meters to display output suitable to accommodate: \n(i) 32A,DP, MCB, 10KA 1No. on Input side & 6" Copper Bus bar mounted on insulators with 2 tap off points suitable for 27V DC, 2 wire, 30A on output side \n{ii] 32A , TPN MCB, 10KA, 1No. on input side & 6" copper bus bar mounted on insulators with 2 tap off points suitable for 380V, 3P., 4wire, 50Hz, 60A/Ph.\n{iii} 63A, TPN MCB, 10KA, 1No. on Input Side &9" long copper bus bar mounted on insulators with 4 tap off points suitable for 220V, 1Ph, 2 wire, 50Hz, 120A\n{iv} 32A DP MCB, 10KA,1No. on input side & 6" copper bus bar mounted on insulators with 2 tap off points suitable for 220V,1Ph, 2 wire, 50Hz,30A BI01010001010000000000000515BI0100001263 1 EACH
155 154 Supply & Fixing wall mounted Sub Output distribution panel made out of 2mm thick CRCA sheet indoor type with VIF meters to display output suitable to accommodate: 160A, MCCB, 25KA, "C" Curve 1No. on Input Side &1.5' long copper bus bar mounted on insulators with 12 tap off points suitable for 220V, 1Ph, 2 wire, 50Hz, 350A. BI01010001010000000000000515BI0100001264 1 EACH
156 155 Supply & Fixing wall mounted Table Supply Box made out of 1.6mm thick CRCA sheet indoor type with Voltmeters to display output suitable to accommodate: 16A DP. MCB, 10KA,27 Volt DC on input side & 16A, 3Pin Industrial type Male Female Socket on output side. BI01010001010000000000000515BI0100001265 24 EACH
157 156 Supply & Fixing wall mounted Table Supply Box made out of 1.6mm thick CRCA sheet indoor type with Voltmeters to display output suitable to accommodate: 16A TPN. MCB, 10KA.40 Volt DC on input side & 16A, 5Pin Industrial type Male Female Socket on output side.\n BI01010001010000000000000515BI0100001266 10 EACH
158 157 Supply & Fixing wall mounted Table Supply Box made out of 1.6mm thick CRCA sheet indoor type with Voltmeters & Frequency Meter to display output suitable to accommodate: 16A TPN. MCB, 10KA .380 Volt on input side & 16A, 5Pin Industrial type Male Female Socket & 15A 5pin normal plug & socket on output side.\n BI01010001010000000000000515BI0100001267 16 EACH
159 158 Supply & Fixing wall mounted Table Supply Box made out of 1.6mm thick CRCA sheet indoor type with Voltmeters to display output suitable to accommodate: 16A DP. MCB, 10KA,220 Volt on input side & 16A, 3Pin Industrial type Male Female Socket & 3Pin 15A & 5A normal plug & socket on output side. BI01010001010000000000000515BI0100001268 74 EACH
160 159 Supply & Fixing wall mounted Table Supply Box made out of 1.6mm thick CRCA sheet indoor type with Voltmeters to display output suitable to accommodate: 16A DP. MCB, 10KA,220 Volt on input side & 16A, 3Pin Industrial type Male Female Socket & 3Pin, 5A normal plug & socket on output side. BI01010001010000000000000515BI0100001269 10 EACH
161 160 Supply & Fixing wall mounted Table Supply Box made out of 1.6mm thick CRCA sheet indoor type with Voltmeters to display output suitable to accommodate: 40A DP. MCB, 10KA,220 Volt on input side & 32A, 3Pin Industrial type Male Female Socket on output side\nNote:- For Sr. 143 to173 Make/Drawing approval to be taken before supply & Installation. BI01010001010000000000000515BI0100001270 40 EACH
162 161 Supply & Fixing of 80mm x 80mm PVC Slotted Cable Trays with all accessories. BI01010001010000000000000515BI0100001271 250 RM
163 162 Supply & Fixing of 100mm x 100mm PVC Slotted Cable Trays with all accessories. BI01010001010000000000000515BI0100001272 150 RM
164 163 Supply, Installation & Fixing of 4 Sq mm single core, flexible, copper cable complete all as specified & directed BI01010001010000000000000515BI0100001273 1200 RM
165 164 Supply, Installation & Fixing of 6 Sq mm single core, flexible, copper cable complete all as specified & directed BI01010001010000000000000515BI0100001274 600 RM
166 165 Supply, Installation & Fixing of 10 Sq mm single core, flexible, copper cable complete all as specified & directed BI01010001010000000000000515BI0100001275 900 RM
167 166 Supply, Installation & Fixing of 16 Sq mm single core, flexible, copper cable complete all as specified & directed BI01010001010000000000000515BI0100001276 1500 RM
168 167 Supply, Installation & Fixing of 25 Sq mm single core, flexible, copper cable complete all as specified & directed BI01010001010000000000000515BI0100001277 500 RM
169 168 Supply, Installation & Fixing of 35 Sq mm single core, flexible, copper cable complete all as specified & directed BI01010001010000000000000515BI0100001278 200 RM
170 169 Supply, Installation & Fixing of 50 Sq mm single core, flexible, copper cable complete all as specified & directed BI01010001010000000000000515BI0100001279 600 RM
171 170 Supply, Installation & Fixing of 120 Sq mm single core, flexible, copper cable complete all as specified & directed BI01010001010000000000000515BI0100001280 150 RM
172 171 Supply, Installation & Fixing of 300 Sq mm single core, flexible, copper cable complete all as specified & directed BI01010001010000000000000515BI0100001281 40 RM
173 172 Supply, Installation & Fixing of 400 Sq mm single core, flexible, copper cable complete all as specified & directed BI01010001010000000000000515BI0100001282 60 RM
174 173 PHASE – II: \nSCHEDULE "A" PART – XVI: CENTRAL AIR CONDITIONING WORKS INCLUDING SUPPLY, INSTALLATION, TESTING & COMMISSIONING [INCLUDING PHASE – I & PHASE – II PERFORMANCE TESTS]: BI01010001010000000000000515BI0100001283
175 174 Supply, installation, testing and commissioning of Screw-type Chiller with actual capacity not less than 100 TR, suitable for ambient conditions, with AHRI certification all as specified hereinafter.\n[i] Supply, installation, testing and commissioning of floor-mounted compact screw-type chiller machine complete with semi-hermitic twin screw type compressors with independent circuits, water-cooled S/T type condenser, S/T horizontal flooded type evaporator with carbon steel shell and seamless copper tubes with 19 mm nitrite rubber insulation, common base frame, interconnected copper refrigerant piping and wiring, vibration isolators, gauge panel, automatic safety controls, flow switch at evaporator and condenser and ozone friendly CFC-free refrigerant gas R-134a/407C. The refrigerant flow control shall use an electronic expansion valve. The chiller shall be designed for a working pressure of 150 psig and hydraulically tested at 225 psig. A number of properly spaced baffles shall be provided for maintaining optimum water velocity and heat transfer and the tubes shall be adequately supported.\nChillers shall be factory AHRI tested at design conditions at 100%, 75%, 50% and 25% load respectively; test certificates shall be produced for all three chillers. The chiller shall be BMS compatible and shall have RS485/RS232 serial communication protocol; the motor shall be suitable for 3- Phase, 415 V ± 10%, 50 Hz AC electric supply; electric panel shall have an IP 54 rating, as per specification and drawings. The chiller shall be as per the approved particular technical specifications and shall meet the following design criteria:\n BI01010001010000000000000515BI0100001284 3 Each
176 175 [a] Chiller \n[i] Chilled Water IN: 54° F\n[ii] Chilled Water OUT: 44° F\n[iii] Fouling Factor: 0.0005 (in FPS units)\n[iv] Water Flow Rate: 2.67 USgpm/TR\n[b] Condenser\n[i] Condenser Water IN: 90° F\n[ii] Condenser Water OUT: 100° F\n[iii] Fouling Factor: 0.001 (in FPS units)\n[iv] Water Flow Rate: 4.25 USgpm/TR\n[c] Minimum COP (at ARI conditions): 4.15\n NOTE : Necessary civil work viz. PCC foundation for placement of chillers shall be covered in the scope of work BI01010001010000000000000515BI0100001285
177 176 Horizontal End Suction Long Coupled type pump with insulation suitable for 240 USgpm water flow rate and 20 m head all as specified hereinafter.\nSupply, installation, testing and commissioning of end-suction & top-discharge, non-self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage high efficiency induction motor, star/delta starter panel, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting, elastomeric thermal insulation of suitable thickness, etc. suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply. (2 W + 1 S) as per specification and drawings\nNOTE :Necessary civil work viz. PCC foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be covered in the scope of work. The pump shall be as per the approved particular technical specifications.\n BI01010001010000000000000515BI0100001286 3 Each
178 177 FRP Bottle shape induced draught cooling tower Capacity : 440 usgpm, for 100 TR water-cooled screw type chiller all as specified hereinafter. \nSupply, installation, testing and commissioning of end-suction & top-discharge, non-self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage high efficiency induction motor, star/delta starter panel, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply. \nNOTE : Necessary civil work viz. PCC foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be covered in the scope of work. The pump shall be as per the approved particular technical specifications and drawings.\n BI01010001010000000000000515BI0100001287 2 Each
179 178 Horizontal Split Casing type pump with insulation suitable for 400 USgpm water flow rate and 20 m head all as specified hereinafter.\nSupply, installation, testing and commissioning of end-suction & top-discharge, non-self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage high efficiency induction motor, star/delta starter panel, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply. \nNOTE : Necessary civil work viz. PCC foundation for placement of pump, mounting of star/delta starter panel and pump accessories shall be covered in the scope of work. The pump shall be as per the approved particular technical specifications and drawings. BI01010001010000000000000515BI0100001288 3 Each
180 179 Supply, installation, testing and commissioning of double-skin type horizontal, floor-mounted, top/side discharge air handling units having corrosion resistant extruded aluminum hollow profile with thermal break, heavy gauge galvanized steel channel base frame, 43 mm double skin panel with pressure injected CFC & HCFC free PUF with 'k' value of 0.02 W/°C m & density 40 kg/cum, pre-coated pre-plasticized galvanized outer and inner skin 0.60mm thick, air-tight casing using gaskets and self-adhesive tapes, AMCA certified energy efficient fans with double inlet double width forward or backward curved impellers for high static pressure mounted on aluminum extruded slide rail base frame, chilled water coils with combination of 6 rows deep with anti-corrosion Aluminum fins, PVC Nylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan, 10 micron pre-filters, inspection windows/doors, mixing box and supply/return/fresh air dampers of capacity 80 TR - 29,300 CFM \n[a] Suitable DIDW fan with AMCA certified blower having outlet velocity not exceeding 9.2 m/s\n[b] 4 Pole, TEFC, high efficiency, squirrel cage induction motor drive having BHP rating 20% higher than the peak capacity, suitable for 415 V ±10%, 50 Hz, 3-Phase AC power supply \n[c] V-belt drive assembly with pulleys, belt, guard, etc., double canvass connections with zip to discharge duct/plenum, etc.\n[d] 50 mm thick, washable HDPE, 90% down 10 micron pre-filters, filters, fixing framework, hinge type access doors, etc.\n BI01010001010000000000000515BI0100001289 1 Each
181 180 [e] 6 row deep chilled water coil section with copper fins and copper tube tested on 21 kg/sq cm with SS sandwiched drain tray, etc.\nNOTE : Necessary civil work viz. PCC foundation for placement of AHU, etc. shall be covered in the scope of work. The AHU shall be as per the approved particular technical specifications and the following design criteria.\n\n BI01010001010000000000000515BI0100001290
182 181 All as per serial item No. 179 & 180 above but of capacity 52 TR-14,400 CFM BI01010001010000000000000515BI0100001291 1 Each
183 182 All as per serial item No. 179 & 180 above but of capacity 47 TR-20,300 CFM BI01010001010000000000000515BI0100001292 1 Each
184 183 S & F HDPE chilled water makeup expansion tank of capacity 500 liters of pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, complete with inter-connection piping, insulated with 50 mm thick insulation covered with sand cement plastering as per specification and drawings BI01010001010000000000000515BI0100001293 1 Each
185 184 S & F HDPE condenser water expansion tank for cooling tower of capacity 2000 liters of pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' with interchangeable EPDM-BUTYL rubber membrane complete with inter-connection piping, etc. as per specification and drawings BI01010001010000000000000515BI0100001294 1 Each
186 185 Supply, installation, testing and commissioning of MS ERW Class 'B' condenser water piping of size 200 mm NB with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden/Puff blocks, etc. as specified in particular specifications and drawings. BI01010001010000000000000515BI0100001295 150 Running Meter
187 186 Supply, installation, testing and commissioning of MS ERW Class 'B' condenser water piping of size 125 mm NB with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden/Puff blocks, etc. all as specified and as shown in drawings. BI01010001010000000000000515BI0100001296 60 Running Meter
188 187 Supply, installation, testing and commissioning of Non chemical type on line scale preventer of size 125mm as per the capacity of the condenser water pump flow all as specified and as shown in drawings BI01010001010000000000000515BI0100001297 1 Each
189 188 Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve of size 125mm NB designed, manufactured and tested as per IS: 13095 (1991), suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection with accessories all as specified and as shown in drawings BI01010001010000000000000515BI0100001298 14 Each
190 189 Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (Non Return Valve) of size 125mm NB, designed & tested as per IS: 5312-2 (1986), suitable to handle clear water having turbidity up to 5000 ppm, having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection, etc. with accessories all as specified and as shown in drawings BI01010001010000000000000515BI0100001299 3 Each
191 190 Supply, installation, testing & commissioning of Y-type strainer of size 125mm NB with CI/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection, etc. with accessories all as specified and as shown in drawings. BI01010001010000000000000515BI0100001300 3 Each
192 191 Supply, installation, testing and commissioning of 2-way, globe type, PN 1.6 rated, balanced/high range ability manual balancing control valve of size 125mm NB all as specified and as shown in drawings complete as per following specification..\nNominal Pressure: PN16\nTemperature: -10° C to +110° C\nBody Material: IS:210, FG 220 CI\nStem Material: ASTM A276,GR SS 410\nDisc Material: Stainless steel Disc\nHand Wheel: Cast Iron\nLeakage Rate: No visible leakage\nMedium Type: Water\nFlange Standard: ISO7005-1 (GB/T 9113)\nShell Test Pressure: 24bar\nSeal Test pressure: 17bar BI01010001010000000000000515BI0100001301 3 Each
193 192 M & L for UPVC pipes and fittings of size 40mm NB, resistant to chemical & electromechanical corrosion, conforming to EN 1452-2, having specific gravity 1.43, shore hardness 70°C to 90° C, tensile strength 500 kg/sq.cm, bending strength 950 kg/sq.cm, modulus of elasticity 3.2 X 10 kg/sq.cm and dielectric strength > 40 kV/mm complete with accessories all as specified and as shown in drawings. BI01010001010000000000000515BI0100001302 20 Running Meter
194 193 Supply, installation, testing and commissioning of MS ERW Class 'B' chilled water piping of size 150mm NB with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden blocks, air-purge valves, drain-valves, etc. thermally insulated with 75 MM thick EPS Pipe Section covered with 26 G Aluminium cladding all as specified and as shown in drawings. BI01010001010000000000000515BI0100001303 65 Running Meter
195 194 Supply, installation, testing and commissioning of MS ERW Class 'B' chilled water piping of size 100mm NB with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden blocks, air-purge valves, drain-valves, etc. thermally insulated with 75 MM thick EPS Pipe Section covered with 26 G Aluminium cladding all as specified and as shown in drawings. BI01010001010000000000000515BI0100001304 120 Running Meter
196 195 Supply, installation, testing and commissioning of MS ERW Class 'B' chilled water piping of size 80mm NB with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden blocks, air-purge valves, drain-valves, etc. thermally insulated with 75 MM thick EPS Pipe Section covered with 26 G Aluminium cladding all as specified and as shown in drawings.\n BI01010001010000000000000515BI0100001305 30 Running Meter
197 196 Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve of size 100mm NB designed, manufactured and tested as per IS: 13095 (1991), suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories all as specified and as shown in drawings. BI01010001010000000000000515BI0100001306 18 Each
198 197 Supply, installation, testing and commissioning of PN 1.6 rated double flanged short & long body type butterfly valve of size 80mm NB designed, manufactured and tested as per IS: 13095 (1991), suitable for isolation and throttling services, having CI body & disc, SS AISI 304 disc seal, CS clamping ring and SS AISI 410 shaft and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories all as specified and as shown in drawings. BI01010001010000000000000515BI0100001307 12 Each
199 198 Supply, installation, testing and commissioning of PN 1.6 rated swing check type multidoor reflux valve (NRV) of size 100mm NB, designed & tested as per IS: 5312-2 (1986), suitable to handle clear water having turbidity up to 5000 ppm, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc. with elastomeric thermal insulation of suitable thickness and accessories all as specified and as shown in drawings. BI01010001010000000000000515BI0100001308 3 Each
200 199 Supply, installation, testing & commissioning of Y-type strainer of size 100mm NB with CI/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with elastomeric thermal insulation of suitable thickness and accessories all as specified and as shown in drawings. BI01010001010000000000000515BI0100001309 3 Each
201 200 Supply, installation, testing and commissioning of 2-way, globe type, PN 1.6 rated, balanced/high range ability control valve of size 100mm NB all as specified and as shown in drawings complete all as per following specification.\nNominal Pressure: PN16\nTemperature: -10° C to +110° C\nBody Material: IS:210, FG 220 CI\nStem Material: ASTM A276,GR SS 410\nDisc Material: Stainless steel Disc\nHand Wheel: Cast Iron\nLeakage Rate: No visible leakage\nMedium Type: Water\nFlange Standard: ISO7005-1 (GB/T 9113)\nShell Test Pressure: 24bar\nSeal Test pressure: 17bar BI01010001010000000000000515BI0100001310 4 Each
202 201 Supply, installation, testing and commissioning of 2-way, globe type, PN 1.6 rated, balanced/high range ability control valve of size 80mm NB all as specified and as shown in drawings complete all as per following specification.\nNominal Pressure: PN16\nTemperature: -10° C to +110° C\nBody Material: IS:210, FG 220 CI\nStem Material: ASTM A276,GR SS 410\nDisc Material: Stainless steel Disc\nHand Wheel: Cast Iron\nLeakage Rate: No visible leakage\nMedium Type: Water\nFlange Standard: ISO7005-1 (GB/T 9113)\nShell Test Pressure: 24bar\nSeal Test pressure: 17bar BI01010001010000000000000515BI0100001311 2 Each
203 202 Supply, installation, testing and commissioning of CI 3-way mixing valve of size 80mm NB, suitable for operation up-to 10 bar, with electronically operated actuator for AHUs. Water flow through the valve shall be regulated by rotation of brass slipper between the main and the bypass ports; it shall be possible to manually rotate the brass slipper through 360° and interchange the main and the common ports, to facilitate installation at site. All internals of the valve shall be rust-proof and the 'O' ring shall be of elastomeric insulation. The valve actuator shall be of electronic type with DC motor, the actuator's angle of rotation shall be 90°, it shall be without any limit switches and shall be overload-proof. It shall have an indicator to indicate the position and push-button to disengage the gear train for manual operation complete with elastomeric thermal insulation of suitable thickness all as specified and as shown in drawings. BI01010001010000000000000515BI0100001312 2 Each
204 203 Supply, installation, testing and commissioning of CI 3-way mixing valve of size 65mm NB, suitable for operation up-to 10 bar, with electronically operated actuator for AHUs. Water flow through the valve shall be regulated by rotation of brass slipper between the main and the bypass ports; it shall be possible to manually rotate the brass slipper through 360° and interchange the main and the common ports, to facilitate installation at site. All internals of the valve shall be rust-proof and the 'O' ring shall be of elastomeric insulation. The valve actuator shall be of electronic type with DC motor, the actuator's angle of rotation shall be 90°, it shall be without any limit switches and shall be overload-proof. It shall have an indicator to indicate the position and push-button to disengage the gear train for manual operation complete with elastomeric thermal insulation of suitable thickness all as specified and as shown in drawings. BI01010001010000000000000515BI0100001313 1 Each
205 204 S & F of CL 150 rated ball valve of size 25mm NB, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fasteners and lever and screwed/socket weld end connection, etc. with accessories all as specified and as shown in drawings. BI01010001010000000000000515BI0100001314 12 Each
206 205 Supply, installation, testing and commissioning of automatic air-vent valve having 19mm end connections with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide capm etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 115° C respectively, installed on all high points in the water piping system to automatically remove the trapped air, installed on all high points in the water piping system to automatically remove the trapped air complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001315 10 Each
207 206 Supply, installation, testing and commissioning Temperature gauge of 100 mm dia for temperature range 0°C to 100°C of glycerin filled bimetallic thermometer in compliance to EN 13190, having standard range 0°C to 60°C up to 400°C, IP 67 protection, bimetal coil sensing element, accuracy class 1 as per EN 13190, stainless steel casing, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 stem and connection, aluminum dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), toughened glass window, neoprene filling plug and gasket complete with accessories, etc all as specified and as shown in drawings. BI01010001010000000000000515BI0100001316 34 Each
208 207 Supply, installation, testing and commissioning Pressure gauge of 100 mm dial size for pressure range 0 psi to 200 psi of glycerin filled pressure gauge in compliance to EN837-1, having standard range 15 to 0 psi and 16 psi to 10000 psi, IP 67 protection, accuracy class ±1.6% of FS, stainless steel casing and TIG argon welded socket to case, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 bourdon, socket, SS dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), polycarbonate glass window, neoprene blow off disc and filling plug, silicon gasket complete with accessories, etc. all as specified and as shown in drawings. BI01010001010000000000000515BI0100001317 46 Each
209 208 Supply, installation, testing and commissioning of pre-fabricated galvanized steel sheet (G.S.S.) square/rectangular ducting with 24 Gauge (MS angle flanges) for supply/return air, fabricated from galvanized steel sheet, having zinc coating of 160 gm/sq m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 with required scaffolding work to install the ducts at site complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001318 320 Square Meter
210 209 Supply, installation, testing and commissioning of pre-fabricated galvanized steel sheet (G.S.S.) square/rectangular ducting with 22 Gauge (MS angle flanges) for supply/return air, fabricated from galvanized steel sheet, having zinc coating of 160 gm/sq m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 with required scaffolding work to install the ducts at site complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001319 300 Square Meter
211 210 Supply, installation, testing and commissioning of pre-fabricated galvanized steel sheet (G.S.S.) square/rectangular ducting with 20 Gauge (MS angle flanges) for supply/return air, fabricated from galvanized steel sheet, having zinc coating of 160 gm/sq m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 with required scaffolding work to install the ducts at site complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001320 100 Square Meter
212 211 Supply, installation, testing and commissioning of pre-fabricated galvanized steel sheet (G.S.S.) square/rectangular ducting with 18 Gauge (MS angle flanges) for supply/return air, fabricated from galvanized steel sheet, having zinc coating of 160 gm/sq m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 with required scaffolding work to install the ducts at site complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001321 60 Square Meter
213 212 Supply, installation, testing and commissioning of fusible link spring return type fire damper complete as required for operation. The fire dampers shall be spring activated on melting of fusible link having melting point 67.13° C. The fire damper shall be located in the SA/RA ducts, at all fire rated crossovers (shafts, walls, etc.). Fire damper shall be tested as per ULL- 555 and certified by CBRI complete all as specified and as shown in drawings.. BI01010001010000000000000515BI0100001322 10 Square Meter
214 213 Supply and fixing Acoustic Insulation with 25mm thick fiber glass rigid boards and finished with RP tissue paper and 28 mm gauge aluminium perforated sheet up to 5 m from outlet of the air plenum including 5 micron filters in air plenum for all AHUs complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001323 180 Square Meter
215 214 Supply and Fixing of Thermal insulation 25mm thick thermal insulation for RA ducts with resin bonded Fiber Glass Wool density 24 KG / Cum] covered with GI chicken wire mesh and cladded with aluminium foil fixed with adhesive tape. complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001324 600 Square Meter
216 215 Under deck insulation in AHU Rooms & Sun exposed slabs with Fire Retardant XPE closed cell of thickness 18 mm with metalized polyester film and self adhesive backing with protection peel off paper. \nMake: Armacell / K – Flex / Arma Flex / Supreme – 8 complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001325 120 Square Meter
217 216 Supply, installation, testing & commissioning of removable supply air [SA] diffusers/grilles 400mm Jet Nozzles with Damper of extruded aluminum sections duly powder coated with volume control damper complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001326 42 Each
218 217 Supply, installation, testing & commissioning of removable Return air [RA] diffusers/grilles of extruded aluminum sections duly powder coated with volume control damper complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001327 14 Square Meter
219 218 Supply, installation, testing & commissioning of 18 G galvanized sheet steel volume control duct damper complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001328 4 Square Meter
220 219 Supply, installation, testing & commissioning of Fresh air damper with GI bowl/ fittings and mosquito proof netting shall be provided for each AHU Room complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001329 3 Each
221 220 Supply, installation, testing & commissioning of Motorized 18 G galvanized sheet steel volume control duct damper with necessary actuator complete all as specified and as shown in drawings. BI01010001010000000000000515BI0100001330 0.5 Square Meter
222 221 Supply, installation, commissioning and testing of AC Plant Electrical panel board, Cubical type, floor mounted, vermi proof, dust proof CPRI approved, Indoor type, Powder Coated with seven tank process switch board panel made out of MS sheet not less than 16 SWG powder coated paint suitable for operation on 415 volt of 50 Hz AC supply internally wired with copper conductor wire, comprising of the following:\n(aa) Air insulated copper bus bar of adequate size for phase and neutral.\n(ab) Main Incoming ACB and outgoing MCCBs of adequate capacity for chilled water pump sets, AHu blower motors, condenser, condenser fans.\n(ac) one digital electronic energy meter of suitable \n(ad) Suitable capacity capacitor to be provided to maintain power factor minimum 0.98.\nThe panel shall be designed and wired in such a manner that the starter for condenser water pump is powered first, after that the cooling tower motor shall be powered, then the chilled water pumps shall be powered and the chiller units should get the supply only if the condenser water pumps, cooling tower motor, and chilled water pumps are in ON condition\nOUT GOINGS:\nChille 100Amps, Four Pole MCCB -4 Nos, (3 W + 1 SB)\nCooling Tower 32 Amps, Four Pole MCCB-4 Nos, (3 W+1 SB)\nPumps 32 Amps, Four Pole MCCB-8 Nos, (6 W+2 SB)\nAHU 7.5 KW -2 Nos, (1 W+1 S)\nAHU 5.5 KW -3 Nos, (1 W+1 S) BI01010001010000000000000515BI0100001331 1 Each
223 222 Supply, installation, commissioning and testing of AHU sub panel board of suitable size, factory made, CPRI type tested, indoor, 18 gauge MS CRCA duly powder coated in compartmentalized construction with incomer and outgoing feeders for AHU motor, 3-way valve actuator motor, Heater Bank/Pan Humidifier, fire damper actuator motor, etc. complete with required variable frequency drive, relays, timers, contactors, PT, push buttons, switches, internal wiring, etc.AHU electrical panels of following Capacity's.\na) 5.5 KW - 2Nos\nb) 7.5 KW - 1 No BI01010001010000000000000515BI0100001332 3 Each
224 223 Supply, laying and Termination of sizes 95.0 Sqmm, 3 core, PVC insulated and PVC sheathed XLPE aluminium conductor UG armoured cable of 1.1 KV grade confirming to IS:7098 (Part-I) 1988 with up to date amendments duly ISI marked complete with necessary Lugs, Glands and accessories as required all as specified and as shown in drawings. BI01010001010000000000000515BI0100001333 90 Running Meter
225 224 Supply, laying and Termination of sizes 16 Sqmm, 4 core, PVC insulated and PVC sheathed XLPE aluminium conductor UG armoured cable of 1.1 KV grade confirming to IS:7098 (Part-I) 1988 with up to date amendments duly ISI marked complete with necessary Lugs, Glands and accessories as required all as specified and as shown in drawings. BI01010001010000000000000515BI0100001334 150 Running Meter
226 225 Supply, laying and Termination of sizes 10 Sqmm, 4 core, PVC insulated and PVC sheathed XLPE aluminium conductor UG armoured cable of 1.1 KV grade confirming to IS:7098 (Part-I) 1988 with up to date amendments duly ISI marked complete with necessary Lugs, Glands and accessories as required all as specified and as shown in drawings. BI01010001010000000000000515BI0100001335 200 Running Meter
227 226 Earthing complete with Copper Earth Plate Electrode 600 X 600 X 3 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 25 x 5mm copper strip [Earth Lead] and GI pipe 400 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. BI01010001010000000000000515BI0100001336 2 Each Job
228 227 M&L for 25 mm X 5 mm copper strip through and including 40 mm dia GI pipe medium grade from earth electrode including connection with brass nut, bolt, spring, washer complete all as specified and as directed.\nNOTE : [i] Rate quoted shall deemed to be included for Supply and laying of 40mm dia GI pipe.\n[ii] Earth work and excavation in any type of soil , returning filling in and removal of excess soil if any shall be measured and paid separately under relevant items of Schedule 'A' part II. BI01010001010000000000000515BI0100001337 30 Running Meter
229 228 Material & Labour for 50 mm X 5 mm copper strip on surface or in recess for connections etc. as required complete all as specified and as directed. BI01010001010000000000000515BI0100001338 30 Running Meter
230 229 Material & Labour for 25 mm X 5 mm G.I strip on surface or in recess for connections etc. as required complete all as specified and as directed. BI01010001010000000000000515BI0100001339 60 Running Meter
231 230 Material & Labour for 6 SWG dia G.I. wire on surface or in recess for loop earthing as required complete all as specified and as directed. BI01010001010000000000000515BI0100001340 80 Running Meter
232 231 Supplying and installing perforated GI. cable trays of size 100 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with suspenders including bolts & nuts, etc as required complete all as specified and as directed. BI01010001010000000000000515BI0100001341 100 Running Meter
233 232 Supplying and installing perforated GI. cable trays of size 150 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with suspenders including bolts & nuts, etc as required complete all as specified and as directed. BI01010001010000000000000515BI0100001342 140 Running Meter
234 233 Supplying and installing perforated GI. cable trays of size 300 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with suspenders including bolts & nuts, etc as required complete all as specified and as directed. BI01010001010000000000000515BI0100001343 80 Running Meter
235 234 PHASE – III: \nSCHEDULE "A" PART – XVII: MAINTENANCE OF ARBORICULTURE WORKS DURING DEFECT LIABILITY PERIOD OF WORK UNDER PHASE – I\nMaintenance of Arboriculture as provided under Serial Item No. 107,111,112 of BoQ by weeding, hosing, saucer melding once in every 15 days, planting new plants / grass in place of dead plants / grass of same species and height with out any extra cost to the department and as directed complete for the period of maintenance period of 12 Months complete all as specified and as directed. \nNote: Rate quoted shall be deemed to include for all labour, materials, tools & plants and regular watering, using sprinklers, including supply and spreading / spraying organic manure, chemical fertilizers, pesticides to the required extent complete all as specified. BI01010001010000000000000515BI0100001344 1 Job
236 235 PHASE – IV: \nSCHEDULE "A" PART – XVIII: OUTSOURCING OF SERVICES FOR OPERATION OF CENTRAL AC PLANT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 174 to 233 OF THIS BOQ / SCHEDULE "A" PART – XVI AFTER SUCCESSFUL COMPLETION OF PHASE – II TESTING i.e. DURING FIRST YEAR OF DEFECT LIABILITY PERIOD OF WORK UNDER PHASE –II:\nOutsourcing for operation of central AC plant of capacity 200 TR (100 TR x 2 Nos working at a time + 1 x 100 TR Standby ) as provided under this contract as per serial Item No 174 to 233 of this BoQ/ Schedule "A" Part- XVI after successful completion of Phase-II testing (i.e. during defect liability period of work under phase-II) complete including cooling towers, AHUs, Electrical Control panels and pumps and connected equipment in complete AC system for 03 shifts of 08 hours each in a day to ensure smooth and trouble free operation of plant to the entire satisfaction of users/department by providing services of one skilled technician of AC & Refrigeration (ITI qualified with 2-3 years relevant experience) separately in each shift of 08 hours all as directed by Engineer-in-charge BI01010001010000000000000515BI0100001345 12 Job Per Month
237 236 PHASE – V: \nSCHEDULE "A" PART – XIX: OUTSOURCING OF SERVICES FOR OPERATION OF CENTRAL AC PLANT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 174 to 233 OF THIS BOQ / SCHEDULE "A" PART – XVI AFTER SUCCESSFUL COMPLETION OF PHASE – II TESTING i.e. DURING SECOND YEAR OF DEFECT LIABILITY PERIOD OF WORK UNDER PHASE –II:\n\nOutsourcing for operation of central AC plant of capacity 200 TR (100 TR x 2 Nos working at a time + 1 x 100 TR Standby ) as provided under this contract as per serial Item no 174 to 233 of this BoQ/ Schedule "A" Part-XVI after successful completion of Phase-II Testing i.e. During Second year of Defect liability period of work under phase-II complete including cooling towers, AHUs, Electrical Control Panels and pumps and connected equipment in complete AC system for 03 shifts of 08 hours each in a day to ensure smooth and trouble free operation of plant to the entire satisfaction of users/department by providing services of one skilled technician of AC & Refrigeration (ITI qualified with 2-3 years relevant experience) separately in each shift of 08 hours all as directed by Engineer-in-charge. BI01010001010000000000000515BI0100001346 12 Job Per Month
238 237 PHASE – VI: \nSCHEDULE "A" PART – XX: OUTSOURCING OF SERVICES FOR OPERATION OF CENTRAL AC PLANT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 174 to 233 OF THIS BOQ / SCHEDULE "A" PART – XVI AND COMPREHENSIVE MAINTENANCE OF CENTRAL AC PLANT FOR THIRD YEAR AFTER SUCCESSFUL COMPLETION OF PHASE – II TESTING [i.e. FIRST YEAR AFTER SUCCESSFUL COMPLETION OF DEFECT LIABILITY PERIOD OF WORK UNDER PHASE – II]\nComprehensive maintenance of central AC plant of capacity 200TR (100 TR x 2 Nos working at a time + 1 x 100 TR Standby) as provided under this contract as per serial Item No 174 to 233 of this BoQ/ Schedule "A" Part XVI and comprehensive maintenance of central AC plant for Third Year after successful completion of phase-II Testing [i.e. First Year after successful completion of Defect Liability period of work under Phase-II including complete cooling towers, AHUs, Electrical Control Panels and Pumps and connected equipment in complete AC system on daily basis to ensure smooth and trouble free operation of plant to the entire satisfaction of users/department by providing services of one skilled technician of AC & Refrigeration (ITI qualified with 2-3 years relevant experience) all as directed by Engineer-in-charge. BI01010001010000000000000515BI0100001347 12 Job Per Month
239 238 Note for Serial Item No. 235 to 237 The quoted rates shall be deemed to include the following operations:\n[a] Preventive and breakdown maintenance of all the equipment by regular oiling, greasing etc as per OEM recommendations.\n[b] To take care of housekeeping, environmental cleanliness of Area up to 20m all around installation shall be kept absolutely neat and clean.\n[c] To maintain all installations provided under this contract as per IE Rules / Standard Engineering Practice and maintenance of Installation Log Books and Maintenance Register.\n[d] All the spares of chillers, cooling towers, AHUs, electrical panels and cost of consumable stores such as greases, lubricants, cotton waste, refrigerants gas filling for leakages [Including cost of gas] and other connected stores etc. required for daily operation and routine maintenance.\n[e] The staff employed shall be having proper uniform as approved by GE.\n[f] The contractor shall arrange dry/wet bulb thermometer for recording hourly room temperature.\n[g] Periodical cleaning of Cooling Tower and AHU Filters shall be the contractor’s responsibility. \n[h] Room temperature and Humidity display unit / instrument shall be provided at plant room for continuous monitoring. BI01010001010000000000000515BI0100001348
240 239 [i] On completion of outsourcing of services for operation of central ac plant and comprehensive maintenance of central ac plant as specified under Serial Item No. 235 to 237 of BoQ, the contractor shall carryout the complete system and controls functional tests before handing over of the plant to department or his successor in presence of user and Engineer-in-Charge. If any components / spares are found defective or unserviceable, the contractor shall replace the same at his own cost in presence of user and Engineer-in-Charge and a certificate to this effect and tests carried out duly signed by the contractor, user and Engineer-in-Charge shall be submitted before claiming the final bill.\n[j] The rate quoted for items of outsourcing shall not be less than minimum wages as notified by government of India/concerned state Government/Local Body, whichever is higher and also not less than applicable rates for contribution of employer towards EPF, contribution to ESIC, contribution of Bonus and LWC under respective headings/sub-items. In case the rates quoted are less than the prevailing rates/instructions under any heading(s), the bid will treated as non-bonafide/invalid, shall be disqualified and such bids will not be considered for acceptance. In such case, the lowest bidder shall be determined from amongst the Valid/bonafide bids only.\n[k] Any variation in minimum wages, liability of EPF/ESIC/Bonus/LWC/GST shall be adjusted for reimbursement/recovery as under:-\n BI01010001010000000000000515BI0100001349
241 240 (l) Variation in minimum wage including other related statutory provisions shall be adjusted in terms of condition 63 of GCC (IAFW-2249).\n(m) variation in percentage/rate of GST and LWC shall be adjusted as per instructions in Annexure XVI of MES Manual on contracts which deals with 'Reimbursement/Refund on Variation in Taxes Directly Related to Contract Value. \n(n) Rates shall be quoted only up to two digits after decimal. If any rate quoted/derived by the contractor works out to more than two digits after decimal, then the same shall be rounded off up to two digits after decimal. The rounding off shall be done in accordance with Rules for Rounding off of Numeric Values in accordance with IS:02 of 1960(Revised 2016) of BIS\n(o) Monthly wages shall be paid by the contractor to the workers/labour only online. Proof of statutory deductions in favour of workers/labour shall be submitted by the contractor to the GE. The contractor will be required to submit copy of valid labour license from the Labour Commissioner within 15 days of commencement of the work. If the contractor fails to submit the same within this stipulated period, the contact shall be liable to be cancelled and the Performance Security of the firm shall be forfeited accordingly. Reference is also invited to this HQ letter No A/37696/Gen/Pol/E2W(PPC) dated 27 Jul 2017 as amended vide letter of even No dated 09 May 2018. BI01010001010000000000000515BI0100001350
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail