Purchase Of Consumable Items On 2 Year Rate Contract Basis Group B., CNC AIIMS, NEW DELHI-Delhi

All India Institute Of Medical Sciences-AIIMS has published Purchase Of Consumable Items On 2 Year Rate Contract Basis Group B.. Submission Date for this Tender is 01-02-2021. Medicine Tenders in CNC AIIMS, NEW DELHI Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

26518460
Purchase Of Consumable Items On 2 Year Rate Contract Basis Group B.
National Competitive Bid
Indian
Delhi
CNC AIIMS, NEW DELHI
01-02-2021

Tender Details

Purchase Of Consumable Items On 2 Year Rate Contract Basis Group B. - Group B1 Ptca Accessories Nitem No. 1: Ptca Inflation Device- Analog Display With Maximum Inflation Pressure Up To 30 Atm N• Efficient Locking System To Maintain High Pressure N• Rapid Inflation And Deflation N• Clear Barrel For Easy Visualization Of De-Bubbling N• Luminescent Analog Pressure Gauge With Scale Of 0 To 30 Atm N• Ergonomic And User-Friendly Handheld Design N N 2 Group B1 Ptca Accessories Nitem No. 2: Ptca Inflation Device- Analog Display With Maximum Inflation Pressure Only Up To 15-20 Atm N• Efficient Locking System To Maintain High Pressure N• Rapid Inflation And Deflation N• Clear Barrel For Easy Visualization Of De-Bubbling N• Luminescent Analog Pressure Gauge With Scale Of 0 To 20 Atm N• Ergonomic And User-Friendly Handheld Design N N 3 Group B1 Ptca Accessories Nitem No. 3: Ptca Inflation Device- Analog Display With Maximum Inflation Pressure Only Up To 10-15 Atm N• Efficient Locking System To Maintain High Pressure N• Rapid Inflation And Deflation N• Clear Barrel For Easy Visualization Of De-Bubbling N• Luminescent Analog Pressure Gauge With Scale Of 0 To 15 Atm N• Ergonomic And User-Friendly Handheld Design N N 4 Group B1 Ptca Accessories Nitem No. 4: Ptca Inflation Device- Analog Display With Maximum Inflation Pressure Beyond 30 Atm N• Efficient Locking System To Maintain High Pressure N• Rapid Inflation And Deflation N• Clear Barrel For Easy Visualization Of De-Bubbling N• Luminescent Analog Pressure Gauge Having Maximum Inflation Pressure Beyond 30 Atm N• Ergonomic And User-Friendly Handheld Design N N 5 Group B1 Ptca Accessories Nitem No. 5: Ptca Inflation Device- Digital Display N• Efficient Locking System To Maintain High Pressure N• Rapid Inflation And Deflation N• Clear Barrel For Easy Visualization Of De-Bubbling N• Ergonomic And User-Friendly Handheld Design N 6 Group B1 Ptca Accessories Nitem No. 6: Y Connector For Ptca – Rotation Type N• Should Accept Catheters Up To 0.096 Inch N• Large Thumb Wheel For Easy Maneuverability N• Luer Connector At The Guiding Catheter End N• Rotating Adapter At The Guiding Catheter End N• Should Fit Comfortably In Hand And Can Be Manipulated Using Single Hand N 7 Group B1 Ptca Accessories Nitem No. 7: Large Bore Y Connector For Ptca – Rotation Type N• Should Accept Catheters Up To 0.115 Inch N• Large Thumb Wheel For Easy Maneuverability N• Luer Connector At The Guiding Catheter End N• Rotating Adapter At The Guiding Catheter End N• Should Fit Comfortably In Hand And Can Be Manipulated Using Single Hand N 8 Group B1 Ptca Accessories Nitem No. 8: Y Connector For Ptca – Push And Pull Type N• Should Accept Catheters Up To 0.096 Inch N• Luer Connector At The Guiding Catheter End N• Rotating Adapter At The Guiding Catheter End N• Should Have Bleed Back Safety Mechanism N• Stepwise Control For Open, Semi-Open And Closed Position N• Should Fit Comfortably In Hand And Can Be Manipulated Using Single Hand N 9 Group B1 Ptca Accessories Nitem No. 9: Large Bore Y Connector For Ptca – Push And Pull Type N• Should Accept Catheters Up To 0.115 Inch N• Luer Connector At The Guiding Catheter End N• Rotating Adapter At The Guiding Catheter End N• Should Have Bleed Back Safety Mechanism N• Stepwise Control For Open, Semi-Open And Closed Position N• Should Fit Comfortably In Hand And Can Be Manipulated Using Single Hand N 10 Group B1 Ptca Accessories Nitem No.10: Y Connector With Extension Tubing ( Haemostatic Y-Connector With Extension Tubing ) For Ptca- Rotating Mechanism N• Should Accept Catheters Up To 0.115 Inch N• Should Have At Least 12-Inch-Long, Large Lumen High Pressure Extension Tubing N• Should Have An Attached 3-Way Connector To The Extension Tubing N• Large Thumb Wheel For Easy Maneuverability N• Luer Connector At The Guiding Catheter End N• Rotating Adapter At The Guiding Catheter End N 11 Group B1 Ptca Accessories Nitem No. 11: Y Connector With Extension Tubing ( Haemostatic Y-Connector With Extension Tubing ) For Ptca- Push Mechanism N• Should Accept Catheters Up To 0.0.096 Inch N• Should Have At Least 12-Inch-Long, Large Lumen High Pressure Extension Tubing N• Should Have An Attached 3-Way Connector To The Extension Tubing N• Large Thumb Wheel For Easy Maneuverability N• Luer Connector At The Guiding Catheter End N• Rotating Adapter At The Guiding Catheter End N 12 Group B1 Ptca Accessories Nitem No. 12: Haemostatic Double Valve Y-Connector For Bifurcation Ptca N• Should Accept Catheters Up To 0.115 Inch N• Two Separate Ports For Insertion Of Interventional Devices N• Luer Connector At The Guiding Catheter End N• Rotating Adapter At The Guiding Catheter End N 13 Group B1 Ptca Accessories Nitem No. 13: Very Large Bore Haemostatic Y-Connector N• Should Accept Catheters Up To 0.170 Inch ( 13 Fr. Size ) N• Large Thumb Wheel For Easy Maneuverability N• Luer Connector At The Guiding Catheter End N• Rotating Adapter At The Guiding Catheter End 14 Group B1 Ptca Accessories Nitem No. 14: Extremely Large Bore Haemostatic Y-Connector N• Should Accept Catheters Up To 0.24 Inch ( 18 Fr. Size ) N• Large Thumb Wheel For Easy Maneuverability N• Luer Connector At The Guiding Catheter End N• Rotating Adapter At The Guiding Catheter End N 15 Group B1 Ptca Accessories Nitem No. 15: Guide Wire Torquer For Coronary Intervention N• Should Hold Guide Wires From 0.009-0.018 Inches N• Ergonomic And User-Friendly Design N 16 Group B1 Ptca Accessories Nitem No. 16: Guide Wire Torquer For Peripheral / Structural Intervention N• Should Hold Guide Wires From 0.018-0.035 Inches N• Ergonomic And User-Friendly Design N 17 Group B1 Ptca Accessories Nitem No. 17: Ptca Guide Wire Insertion Tool N• 20 G Size N• 10 -12 Cm Long Metallic Shaft N• Should Allow To 0.018-Inch Guide Wire N 18 Group B2 Ptca Accessories Nitem No. 1: Ptca Accessory Kit Containing N• One Hemostatic Y Connector N• One Ptca Guide Wire Torquer N• One Ptca Guide Wire Insertion Tool N 19 Group B2 Ptca Accessories Nitem No. 2: Ptca Inflation Device With Accessory Kit Containing Y Connector N• Must Have One Ptca Inflation Device With Luminescent Analog Pressure Gauge ( Up To 30 Atm ) N• Must Have One Hemostatic Y Connector With N• Must Have One Ptca Guide Wire Torquer N• Must Have One Ptca Guide Wire Insertion Tool N• Should Be Able To Provide Inflation Device With Both Maximum Inflation Pressures Up To 20 Atm Only And 30 Atm Only N• Should Be Able To Provide The Y Connector With Choice Of Rotation Lock, Push-Pull Lock Or Dual Valve Mechanism N• Should Be Able To Provide Y Connector In Lumen Sizes Up To 0.115 Inch N N 20 Group B2 Ptca Accessories Nitem No. 3: Ptca Inflation Device With Accessory Kit Containing Y Connector With Rotation Lock N• Must Have One Ptca Inflation Device With Luminescent Analog Pressure Gauge ( Up To 30 Atm ) N• Must Have One Hemostatic Y Connector With Rotation Lock And Bore Up To 0.096 Inch N• Must Have One Ptca Guide Wire Torquer N• Must Have One Ptca Guide Wire Insertion Tool N N 21 Group B2 Ptca Accessories Nitem No. 4: Ptca Inflation Device With Accessory Kit Containing Large Bore Y Connector With Rotation Lock N• Must Have One Ptca Inflation Device With Luminescent Analog Pressure Gauge ( Up To 30 Atm ) N• Must Have One Hemostatic Y Connector With Rotation Lock And Bore Up To 0.115 Inch N• Must Have One Ptca Guide Wire Torquer N• Must Have One Ptca Guide Wire Insertion Tool N N 22 Group B2 Ptca Accessories Nitem No. 5: Ptca Inflation Device With Accessory Kit Containing Y Connector With Push-Pull Lock Mechanism N• Must Have One Ptca Inflation Device With Luminescent Analog Pressure Gauge ( Up To 30 Atm ) N• Must Have One Hemostatic Y Connector With Push-Pull Lock And Bore Up To 0.096 Inch N• Must Have One Ptca Guide Wire Torquer N• Must Have One Ptca Guide Wire Insertion Tool N N 23 Group B2 Ptca Accessories Nitem No. 6: Ptca Inflation Device With Accessory Kit Containing Y Connector N• Must Have One Ptca Inflation Device With Luminescent Analog Pressure Gauge ( Up To 30 Atm ) N• Must Have One Hemostatic Y Connector With Rotation Lock And Bore Up To 0.096 Inch N• Must Have One Ptca Guide Wire Torquer N• Must Have One Ptca Guide Wire Insertion Tool N N 24 Group B2 Ptca Accessories Nitem No. 7: Disposable Plastic Sterile Control Syringe For Angiography And Ptca N• Clear, Glass-Like Plastic Syringe N• Markings Up To 10- 12 Ml N• Single Hand Palm And Finger Assisted Maneuverability N• Plunger Should Have Resistance Free Movement N• Should Have A Stopper With 0.5 Ml Reserve N• Should Be Individually Packed N N 25 Group B2 Ptca Accessories Nitem No. 8: Disposable Plastic Sterile Luer Lock Syringe For Angiography And Ptca N• Clear, Glass-Like Medical Grade Plastic Syringe Made Up Of Three Parts: Barrel, Plunger And Latex Piston N• Markings Up To 10 Ml N• Plunger Should Have Resistance Free Movement N• Should Have Luer Lock Mechanism For Attachment N• Should Be Individually Packed N N 26 Group B2 Ptca Accessories Nitem No. 9: Disposable Plastic Sterile Luer Lock Syringe For Angiography And Ptca N• Clear, Glass-Like Medical Grade Plastic Syringe Made Up Of Three Parts: Barrel, Plunger And Latex Piston N• Markings Up To 12 Ml N• Plunger Should Have Resistance Free Movement N• Should Have Luer Lock Mechanism For Attachment N• Should Be Individually Packed N N 27 Group B2 Ptca Accessories Nitem No. 10: Manifold With Two Side Ports For Angiography And Ptca N• Large Bore / I.D ( At Least 0.093 Inch ) For Easy Flow Of Contrast N• Smooth Resistance Free Uni-Direction Handle / Knob N• Should Have Clear Body For Controlled Debubbling N• Should Be Available In Both Block And Half-Body Styles N• Should Take Pressures Up To 500 Psi N N 28 Group B2 Ptca Accessories Nitemno. 11: Manifold With Three Side Ports For Ptca N• Large Bore / I.D ( At Least 0.093 Inch ) For Easy Flow Of Contrast N• Smooth Resistance Free Uni-Direction Handle / Knob N• Should Have Clear Body For Controlled Debubbling N• Should Be Available In Both Block And Half-Body Styles N• Should Take Pressures Up To 500 Psi N N 29 Group B2 Ptca Accessories Nitem No. 12: Connector Tubing ( Connecting Between Touhy Borst And Manifold ) N• Should Be Between 25- 50 Cm N• Should Have Large I.D For Easy Flow Of Contrast N• Should Take High Pressure N• Should Be Flexible N• Should Have Male And Female Hubs N N 30 Group B2 Ptca Accessories Nitem No. 13: Connector Tubing ( Connecting Between Y Connector And Manifold ) With Attached Three-Way Stop Cock N• Should Be Between 20-50 Cm Long N• Should Have Large I.D For Easy Flow Of Contrast N• Should Take High Pressure N• Should Be Flexible N• Should Have Attached Three-Way Stopcock At One End N N 31 Group B2 Ptca Accessories Nitem No. 14: Contrast Tubing ( Connecting Between Contrast Bottle And Manifold ) N• Should Have Large I.D For Easy Flow Of Contrast N• Should Be Flexible N• Should Have Flow Regulating Knobs N N 32 Group B2 Ptca Accessories Nitem No. 15: Manifold With Attached Tubings N• Two / Three Side Port Manifold N• One Connector Tubing For Connecting Manifold To Y Connector N• One Large Bore Contrast Tubing ( With Flow Regulating Knob ) For Attachment Between Contrast Bottle & Manifold Side Port N• One Luer Lock Three-Piece Disposable Syringe Having Markings Up To 10- 12 Ml For Contrast Injection N N 33 Group B2 Ptca Accessories Nitem No. 16: Ptca Accessories Kit: Should Contain The Following Items N• Hemostatic Y- Connector N• One Two / Three Side-Port Manifold N• One Connector Tubing For Connecting Manifold To Y Connector N• One Luer Lock Three-Piece Disposable Syringe Having Markings Up To 10- 12 Ml For Contrast Injection N• One Ptca Guide Wire Insertion Needle N• One Ptca Guide Wire Torquer N• One Large Bore Contrast Tubing ( With Flow Regulating Knob ) For Attachment Between Contrast Bottle & Manifold Side Port N• One Three Way Stop Cock N N 34 Group B2 Ptca Accessories Nitem No. 17: Ptca Accessories Combo Pack: Should Contain The Following Items N• One Ptca Inflation Device N• Hemostatic Y- Connector N• One Two / Three Side-Port Manifold N• One Connector Tubing For Connecting Manifold To Y Connector N• One Luer Lock Three-Piece Disposable Syringe Having Markings Up To 10- 12 Ml For Contrast Injection N• One Ptca Guide Wire Insertion Needle N• One Ptca Guide Wire Torquer N• One Large Bore Contrast Tubing ( With Flow Regulating Knob ) For Attachment Between Contrast Bottle & Manifold Side Port N• One Three Way Stop Cock N N 35 Group B3 Guiding Catheters For Ptca Nitem No. 1: Ptca Guiding Catheters Of 6- 7 French Sizes N• Must Have 6- 7 Fr. Guiding Catheters N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Others. N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Soft Short Tip Catheters N 36 Group B3 Guiding Catheters For Ptca Nitem No. ¬¬2: Ptca Guiding Catheters Of 5 French Size N• Must Have 5 Fr. Guiding Catheters N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Others. N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Soft Short Tip Catheters N 37 Group B3 Guiding Catheters For Ptca Nitem No. ¬¬3: Ptca Guiding Catheters Of 8 French Sizes N• Must Have 8 Fr. Guiding Catheters N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Others. N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Soft Short Tip Catheters N 38 Group B3 Guiding Catheters For Ptca Nitem No. ¬¬4: Special Large Lumen Ptca Guiding Catheters Of 6 French Size N• Must Have 6Fr. Guiding Catheters With I.D Of 0.071 Inch Or More N• Failure To Comply With The Specifications Will Lead To Rejection As A Whole From This Item. N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Others. N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Soft Short Tip Catheters N• It Should Retain Its Shape For Multi-Vessel Coronary Intervention N• It Should Be Kink Resistant N 39 Group B3 Guiding Catheters For Ptca Nitem No. ¬¬5: Special Large Lumen Ptca Guiding Catheters Of 6 French Size With Side Holes N• Must Have 6Fr. Guiding Catheters With I.D Of 0.071 Inch Or More N• Failure To Comply With The Specifications Will Lead To Rejection As A Whole From This Item. N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Others. N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Soft Short Tip Catheters N• It Should Retain Its Shape For Multi-Vessel Coronary Intervention N• It Should Be Kink Resistant N 40 Group B3 Guiding Catheters For Ptca Nitem No. ¬¬6: Special Large Lumen Ptca Guiding Catheters Of 7 French Size N• Must Have 7Fr. Guiding Catheters With I.D Of 0.081 Inch Or More N• Failure To Comply With The Specifications Will Lead To Rejection As A Whole From This Item. N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Others. N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Soft Short Tip Catheters N• It Should Retain Its Shape For Multi-Vessel Coronary Intervention N• It Should Be Kink Resistant N 41 Group B3 Guiding Catheters For Ptca Nitem No. ¬¬7: Special Large Lumen Ptca Guiding Catheters Of 7 French Size With Side Holes N• Must Have 7Fr. Guiding Catheters With I.D Of 0.081 Inch Or More N• Failure To Comply With The Specifications Will Lead To Rejection As A Whole From This Item. N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Others. N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Soft Short Tip Catheter N• It Should Retain Its Shape For Multi-Vessel Coronary Intervention N• It Should Be Kink Resistant N 42 Group B3 Guiding Catheters For Ptca Nitem No. ¬¬8: Special Large Lumen Ptca Guiding Catheters Of 8 French Size N• Must Have 8Fr. Guiding Catheters With I.D Of 0.090 Inch Or More N• Failure To Comply With The Specifications Will Lead To Rejection As A Whole From This Item. N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Others. N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Soft Short Tip Catheters N• It Should Retain Its Shape For Multi-Vessel Coronary Intervention N• It Should Be Kink Resistant N 43 Group B3 Guiding Catheters For Ptca Nitem No. ¬¬9: Special Large Lumen Ptca Guiding Catheters Of 8 French Size With Side Holes N• Must Have 8Fr. Guiding Catheters With I.D Of 0.090 Inch Or More N• Failure To Comply With The Specifications Will Lead To Rejection As A Whole From This Item. N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Others. N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Soft Short Tip Catheter N• It Should Retain Its Shape For Multi-Vessel Coronary Intervention N• It Should Be Kink Resistant N 44 Group B3 Guiding Catheters For Ptca Nitem No. ¬¬10: Special Large Lumen Ptca Guiding Catheters Of 5 French Size N• Must Have 5 Fr. Guiding Catheters With I.D Of 0.058 Inch Or More N• Failure To Comply With The Specifications Will Lead To Rejection As A Whole From This Item. N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Others. N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Soft Short Tip Catheters N• It Should Retain Its Shape For Multi-Vessel Coronary Intervention N• It Should Be Kink Resistant N 45 Group B3 Guiding Catheters For Ptca Nitem No. ¬¬11: Special Large Lumen Ptca Guiding Catheters Of 5 French Size With Side Holes N• Must Have 5 Fr. Guiding Catheters With I.D Of 0.058 Inch Or More N• Failure To Comply With The Specifications Will Lead To Rejection As A Whole From This Item. N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Others. N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Soft Short Tip Catheter N• It Should Retain Its Shape For Multi-Vessel Coronary Intervention N• It Should Be Kink Resistant N 46 Group B3 Guiding Catheters For Ptca Nitem No. 12: 4 Fr Guide Catheter For Ptca In Various Shapes 47 Group B3 Guiding Catheters For Ptca Nitem No. 13: Hydrophilic Coated Ptca Guiding Catheter For Difficult Vascular Access N• Must Have 5- 8 Fr. Guiding Catheters N• Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Hockey Stick, Bypass-Graft, Lima Interventions And Radial Curves N• Should Also Have Soft Short Tip Catheters N 48 Group B3 Guiding Catheters For Ptca Nitem No. 14: Ptca Guiding Catheter Dedicated For Transradial Interventions N• Sizes Of 5 Fr And 6 Fr N• Should Have All Possible Shapes And Variation For Transradial Interventions N• Should Also Have Soft Atraumatic Tip N 49 Group B3 Guiding Catheters For Ptca Nitem No. 15: Ptca Guiding Catheter Dedicated For Transradial Interventions For Hooking Both Right And Left Coronaries In Single Pass N• Sizes Of 5 Fr And 6 Fr N• Should Have All Possible Shapes And Variation For Transradial Interventions N• Should Also Have Soft Atraumatic Tip N• Must Have Curves Appropriate For Hooking Both Rca And Lca With The Same Catheter Design And Curve N 50 Group B3 Guiding Catheters For Ptca Nitem No. 16: Ptca Guiding Catheter With Side Holes Dedicated For Transradial Interventions N• Sizes Of 5 Fr And 6 Fr N• Should Have All Possible Shapes And Variation For Transradial Interventions N• Should Also Have Soft Atraumatic Tip N 51 Group B3 Guiding Catheters For Ptca Nitem No. 17: Ptca Guiding Catheter With Side Holes Dedicated For Transradial Interventions For Hooking Both Right And Left Coronaries In Single Pass N• Sizes Of 5 Fr And 6 Fr N• Should Have All Possible Shapes And Variation For Transradial Interventions N• Should Also Have Soft Atraumatic Tip N• Must Have Curves Appropriate For Hooking Both Rca And Lca With The Same Catheter Design And Curve N 52 Group B3 Guiding Catheters For Ptca Nitem No. 18: Special Large Lumen Ptca Guiding Catheter Dedicated For Transradial Interventions N• Must Have 5Fr And 6Fr Guide Catheters No 5Fr Should Have Id Of 0.058 Inch Or More No 6Fr Should Have Id Of 0.071 Inch Or More N• Should Have All Possible Shapes And Variation For Transradial Interventions N• Should Also Have Soft Atraumatic Tip N 53 Group B3 Guiding Catheters For Ptca Nitem No. 19: Special Large Lumen Ptca Guiding Catheter Dedicated For Transradial Interventions For Hooking Both Right And Left Coronaries In Single Pass N• Must Have 5Fr And 6Fr Guide Catheters No 5Fr Should Have Id Of 0.058 Inch Or More No 6Fr Should Have Id Of 0.071 Inch Or More N• Should Have All Possible Shapes And Variation For Transradial Interventions N• Should Also Have Soft Atraumatic Tip N• Must Have Curves Appropriate For Hooking Both Rca And Lca With The Same Catheter Design And Curve N 54 Group B3 Guiding Catheters For Ptca Nitem No. 20: Special Large Lumen Ptca Guiding Catheter With Side Holes Dedicated For Transradial Interventions N• Must Have 5Fr And 6Fr Guide Catheters No 5Fr Should Have Id Of 0.058 Inch Or More No 6Fr Should Have Id Of 0.071 Inch Or More N• Should Have All Possible Shapes And Variation For Transradial Interventions N• Should Also Have Soft Atraumatic Tip N 55 Group B3 Guiding Catheters For Ptca Nitem No. 21: Special Large Lumen Ptca Guiding Catheter With Side Holes Dedicated For Transradial Interventions For Hooking Both Right And Left Coronaries In Single Pass N• Must Have 5Fr And 6Fr Guide Catheters No 5Fr Should Have Id Of 0.058 Inch Or More No 6Fr Should Have Id Of 0.071 Inch Or More N• Should Have All Possible Shapes And Variation For Transradial Interventions N• Should Also Have Soft Atraumatic Tip N• Must Have Curves Appropriate For Hooking Both Rca And Lca With The Same Catheter Design And Curve N 56 Group B3 Guiding Catheters For Ptca Nitem No. 22: Special Sheathless Ptca Guiding Catheter Dedicated For Transradial Interventions N• Sizes Of 5 Fr, 6 Fr And 7 Fr N• Should Have All Possible Shapes And Variation For Transradial Interventions N• Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) N• Should Also Have Availability Of Catheters With Side Holes N• Should Also Have Soft Short Tip Catheters N 57 Group B3 Guiding Catheters For Ptca Nitem No. 23: Ptca Guide Extension Catheter For Rapid Exchange Compatible And Enhancing The Support Of 6 Fr And 7 Fr Guide Catheter N• Compatible With 6 Fr And 7 Fr Guide Catheter N• Rapid Exchange Length Of 25 Cm With 150 Cm Working Length N• Guide Extension Segment Of 25 Cm N 58 Group B3 Guiding Catheters For Ptca Nitem No. 24: Ptca Guide Extension Catheter For Rapid Exchange Compatible And Enhancing The Support Of 5 Fr And 5.5 Fr Guide Catheter N• Compatible With 5 Fr And 5.5 Fr Guide Catheter N• Rapid Exchange Length Of 25 Cm With 150 Cm Working Length N• Guide Extension Segment Of 25 Cm N 59 Group B3 Guiding Catheters For Ptca Nitem No. 25: Ptca Guide Extension Catheter For Rapid Exchange Compatible And Enhancing The Support Of 8 Fr Guide Catheter N• Compatible With 8 Fr Guide Catheter N• Rapid Exchange Length Of 25 Cm With 150 Cm Working Length N• Guide Extension Segment Of 25 Cm N 60 Group B3 Guiding Catheters For Ptca Nitem No. 26: Special Large Lumen Ptca Guide Extension Catheter For Rapid Exchange Compatible And Enhancing The Support Of 6 Fr And 7 Fr Guide Catheter N• Compatible With 6 Fr And 7 Fr Guide Catheter N• Must Have Id As Follows: No 6 Fr: 0.057 Inch Or More No 7 Fr: 0.063 Inch Or More N• Rapid Exchange Length Of 25 Cm With 150 Cm Working Length N• Guide Extension Segment Of 25 Cm N 61 Group B3 Guiding Catheters For Ptca Nitem No. 27: Special Large Lumen Ptca Guide Extension Catheter For Rapid Exchange Compatible And Enhancing The Support Of 8 Fr Guide Catheter N• Compatible With 8 Fr Guide Catheter N• Must Have Id As Follows: No 8 Fr: 0.072 Inch Or More N• Rapid Exchange Length Of 25 Cm With 150 Cm Working Length N• Guide Extension Segment Of 25 Cm N 62 Group B3 Guiding Catheters For Ptca Nitem No. 28: Over The Wire Ptca Guide Extension Catheter Over The Wire Compatible With 6F, 7F And 8F For Enhancing Their Support N 63 Group B3 Guiding Catheters For Ptca Nitem No. 29: Ptca Guide Extension Catheter With The Option Of Trapping Balloon – Guide Extension Catheter With Inbuilt Trapping Balloon To Maintain Guidewire Position N 64 Group B3 Guiding Catheters For Ptca Nitem No. 30: Trapping Balloon Catheter N• Should Have Auto Stop Mechanism N• Should Have Small Shaft Profile And Easily Pushable Shaft N• Should Be Designed To Trap A Coronary Guidewire At Low Inflation Pressure N 65 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 1: Ptca Guide Wire Having Regular Shaft Support With Floppy Tip N• Should Be Available In Both Routine And Exchange Lengths N 66 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 2: Ptca Guide Wire With Extra-Support Shaft And Floppy Tip N• Should Be Available In Both Routine And Exchange Lengths N 67 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 3: Polymer Covered Ptca Guide Wire With Distal Spring Coil N• Should Have Hydrophilic Polymer Cover N 68 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 4: Polymer Covered Ptca Guide Wire Without Distal Spring Coil N• Should Have Hydrophilic Polymer Cover N 69 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 5: Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Non-Tapering Distal Tip N• Should Be Of 0.014-Inch Diameter, Non-Tapering Distal Tip N• Should Not Have Any Polymer Coating N 70 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 6: Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering Distal Tip N• Should Be Of 0.014-Inch Diameter With Tapering Distal Tip N• Should Not Have Any Polymer Coating N 71 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 7: Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering 0.012 Inch Distal Tip N• Should Be Of 0.014-Inch Diameter, Distal Tip Tapering To 0.012 Inch N• Should Not Have Any Polymer Coating N 72 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 8: Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering 0.011 Inch Distal Tip N• Should Be Of 0.014-Inch Diameter, Distal Tip Tapering To 0.011 Inch N• Should Not Have Any Polymer Coating N 73 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 9: Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering 0.010 Inch Distal Tip N• Should Be Of 0.014-Inch Diameter, Distal Tip Tapering To 0.010 Inch N• Should Not Have Any Polymer Coating N 74 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 10: Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering 0.009 Inch Distal Tip N• Should Be Of 0.014-Inch Diameter, Distal Tip Tapering To 0.009 Inch N• Should Not Have Any Polymer Coating N 75 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 11: Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering 0.008 Inch Distal Tip N• Should Be Of 0.014-Inch Diameter, Distal Tip Tapering To 0.008 Inch N• Should Not Have Any Polymer Coating N 76 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 12: Polymer Covered Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Non-Tapering Distal Tip N• Should Be Of 0.014-Inch Diameter, Non-Tapering Distal Tip N 77 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 13: Polymer Covered Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering Distal Tip N• Should Be Of 0.014-Inch Diameter With Tapering Distal Tip N 78 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 14: Polymer Covered Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering 0.012 Inch Distal Tip N• Should Be Of 0.014-Inch Diameter, Distal Tip Tapering To 0.012 Inch N 79 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 15: Polymer Covered Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering 0.011 Inch Distal Tip N• Should Be Of 0.014-Inch Diameter, Distal Tip Tapering To 0.011 Inch N 80 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 16: Polymer Covered Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering 0.010 Inch Distal Tip N• Should Be Of 0.014-Inch Diameter, Distal Tip Tapering To 0.010 Inch N• Should Not Have Any Polymer Coating N 81 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 17: Polymer Covered Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering 0.009 Inch Distal Tip N• Should Be Of 0.014-Inch Diameter, Distal Tip Tapering To 0.009 Inch N 82 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 18: Polymer Covered Ptca Guide Wire Dedicated For Chronic Total Occlusion Having Tapering 0.008 Inch Distal Tip N• Should Be Of 0.014-Inch Diameter, Distal Tip Tapering To 0.008 Inch N 83 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 19: Ptca Guide Wires Dedicated For Chronic Total Occlusion Having Tip Load Of 1-2 Gms N 84 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 20: Ptca Guide Wires Dedicated For Chronic Total Occlusion Having Tip Load Of 2-3 Gms N 85 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 21: Ptca Guide Wires Dedicated For Chronic Total Occlusion Having Tip Load Of 3-6 Gms N 86 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 22: Ptca Guide Wires Dedicated For Chronic Total Occlusion Having Tip Load Of 6-9 Gms 87 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 23: Ptca Guide Wires Dedicated For Chronic Total Occlusion Having Tip Load 9-12 Gms 88 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 24: Ptca Guide Wires Dedicated For Chronic Total Occlusion Having Tip Load 12-15 Gms 89 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 25: Ptca Guide Wires Dedicated For Chronic Total Occlusion Having Tip Load More Than 15 Gms 90 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 26: Ptca Guide Wires For Chronic Total Occlusion Dedicated For Retrograde Approach 91 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 27: Ptca Guide Wires Dedicated For Retrograde Chronic Total Occlusion For Negotiating Collaterals 92 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 28: Ptca Guide Wires Dedicated For Complex Antrgrade Chronic Total Occlusion Interventions 93 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 29: Ptca Guide Wires Dedicated For Complex Chronic Total Occlusion Interventions For Sub-Intimal Tracking And Reentry 94 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 30: Ptca Guide Wire With Floppy Tip And Extra-Support Shaft Strength Having Lateral Support Of 20-25 Gms At 155Mm Of Wire 95 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 31: Heavy Duty Ptca Guide Wire With Floppy Tip Having Lateral Support Of 25 -50 Gms At 155Mm Of Wire 96 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 32: Very Heavy Duty Ptca Guide Wire With Floppy Tip Having Lateral Support Of More Than 50 Gms At 155 Mm Of Wire 97 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 33: Ptca Guide Wire With Floppy Tip Having Multiple Markers For Measuring The Length Of Stenotic Segment 98 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 34: Ptca Guide Wire With Extra Support Shaft And Floppy Tip Having Multiple Markers For Measuring The Length Of Stenotic Segment 99 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 35: Ptca Guide Wire Having Stailess Steel Core Material And Floppy Core To Tip Design N• Should Have A Stainless Steel Core Material N• Should Have A Shaping Ribbon Tip Wire Tip Style N• Should Have A Non-Tapering Distal Tip N• Should Have An Extreme Floppy Tip With Tip Load = 0.5 Gm N 100 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 36: Ptca Guide Wire With Stainless Steel Core Having Extra Support Shaft For Complex Coronary Interventions N• Should Have Stainless Steel Core Material N• Should Have A Core-To-Tip Wire Tip Style N• Should Have A Non-Tapering Distal Tip N• Should Have A Floppy Tip With Tip Load = 1.0 Gm N• Should Have A Hydrophobic Coating N• Should Provide Extra-Support For Complex Coronary Interventions N 101 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 37: Ptca Guide Wire Having Stainles Steel Core And Tapering Tip Dedicated For Chronic Total Occlusion N• Should Have Stainless Steel Core Material N• Should Have A Core-To-Tip Wire Tip Style N• Should Have A Tapering Distal Tip, Tip Tapering To 0.010 Inch N• Should Be Available In Variants Having Different Tip Loads N• Should Have A Hydrophilic Coating N 102 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 38: Ptca Guide Wire Having Stainless Steel Core And Sinusoidal Shaft Design N• Should Have Stainless Steel Core Material N• Should Have A Shaping Ribbon Wire Tip Style N• Should Have A Non-Tapering Distal Tip N• Should Have An Extreme Floppy Tip With Tip Load = 0.5 Gm N• Should Have A Hydrophilic Coating N• Should Have A Distal Portion Of The Guide Wire With Sinusoidal Design N 103 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 39: Ptca Guide Wire Having Elastinite Nitinol Core And Floppy Core To Tip Design N• Should Have A Non-Kinkable Elastinite- Nitinol Core Material N• Should Have A Core-To-Tip Wire Tip Style N• Should Have A Non-Tapering Distal Tip N• Should Have A Floppy Tip With Tip Load = 0.8 Gm N• Should Be Available In Both Regular And Exchange Length Wires N 104 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 40: Ptca Guide Wires Having Elastinite Nitinol Core And Floppy Shaping Ribbon Tip Design N• Should Have A Non-Kinkable Elastinite- Nitinol Core Material N• Should Have A Shaping Ribbon Wire Tip Style N• Should Have A Non-Tapering Distal Tip N• Should Have A Floppy Tip With Tip Load = 0.8 Gm N• Should Be Available In Both Regular And Exchange Length Wires N 105 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 41: Ptca Guide Wire With Extra Support Shaft Having Elastinite Nitinol Core For Complex Coronary Interventions N• Should Have A Non-Kinkable Elastinite- Nitinol Core Material N• Should Have A Shaping Ribbon Wire Tip Style N• Should Have A Non-Tapering Distal Tip N• Should Have A Floppy Tip With Tip Load = 0.8 Gm N• Should Provide Extra-Support For Complex Coronary Interventions N 106 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 42: Ptca Guide Wire Having Durasteel Core With Floppy Tip N• Should Have Durasteel Core Material N• Should Have A Core-To-Tip Wire Tip Style N• Should Have A Non-Tapering Distal Tip N• Should Be Available In Tip Loads = 1.0 Gm N• Should Have A Hydrophilic Coating N 107 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 43: Ptca Guide Wire Having Durasteel Core Dedicated For Cto Lesions N• Should Have Durasteel Core Material N• Should Have A Core-To-Tip Wire Tip Style N• Should Have A Non-Tapering Distal Tip N• Should Be Available In Variants Having Different Tip Loads N• Should Have A Hydrophilic Coating N• Should Have A Polymer Sleeve Covering N 108 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 44: Ptca Guide Wire With Durasteel Core Having Tapering Tip Dedicated For Cto Lesions N• Should Have Durasteel Core Material N• Should Have A Core-To-Tip Wire Tip Style N• Should Have A Tapering Distal Tip, Tapering To 0.009-0.0105 Inches N• Should Be Available In Variants Having Different Tip Loads N• Should Have A Hydrophilic Coating N• Should Have A Polymer Sleeve Covering N 109 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 45: Polymer Covered Ptca Guide Wire Having Durasteel Core N• Should Have Durasteel Core Material N• Should Have A Core-To-Tip Wire Tip Style N• Should Have A Non-Tapering Distal Tip N• Should Have A Wires With Varying Tip Loads Between 0.8-1.2 Gm N• Should Have A Hydrophilic Coating N• Should Have A Full Polymer Cover N• Should Be Available In Variants Having Different Shaft Support N 110 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 46: Polymer Covered Ptca Guide Wire Having Durasteel Core Dedicated For Cto Lesions N• Should Have Durasteel Core Material N• Should Have A Core-To-Tip Wire Tip Style N• Should Have A Non-Tapering Distal Tip N• Should Have Wires With Varying Tip Loads Between 1.2-5.0 Gm N• Should Have A Hydrophilic Coating N• Should Have A Full Polymer Cover N 111 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 47: Ptca Guide Wire Having Fused Stainless Steel And Nitinol Cores N• Should Have Nitinol ( Distal ) Core And Stainless Steel ( Shaft ) Core N• Wire Cores Fused Using “Duo-Core” Technology Having 1:1 Torque Transmission N• Should Have A “M Coat” Distal Hydrophilic Coating N• Should Be Available In Both Routine And Exchange Lengths N 112 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 48: Ptca Guide Wire Having With Super Elastic Nitinol Alloy Core N For Chronic Total Occlusion N• Should Be Of 0.014-Inch Diameter, Non-Tapering Distal Tip N• Should Have Polyurethane Distal Tip N• Should Have “M-Coat” For Hydrophilic Coating N 113 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 49: Ptca Guide Wire Having Jointless Distal Spring Coil N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have Hydrophilic Slip-Coat Coating Over The Distal Wire N• Should Have A Non-Tapering Distal Tip N• Should Have A Tip Load Of 0.8 Gm N 114 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 50: Ptca Guide Wire With Extra Support Shaft Having Jointless Distal Spring Coil N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Core To Tip Design N• Should Have A Non-Tapering Distal Tip N• Should Have A Silicone Hydrophobic Coating Over The Spring Coil N• Should Have A Tip Load Of 0.7 Gm N• Should Not Have Any Polymeric Cover N 115 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 51: Ptca Guide Wire Having Composite Core And Jointless Distal Spring Coil N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Composite Core With Actone Inside N• Should Have A Non-Tapering Distal Tip N• Should Have Hydrophilic Slip-Coat Coating Over The Distal Wire N• Should Have Wire Tip Load Of 0.7 Gm N 116 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 52: Ptca Guide Wire Having Composite Core And Jointless Distal Spring Coil N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Composite Core With Actone Inside N• Should Have A Non-Tapering Distal Tip N• Should Have A Hybrid Coating With Hydrophobic Silicone Coating Over The Distal Most Tip And A Hydrophilic Slip-Coat Coating Proximally N• Should Have Tip Load Of 0.5 Gm N• Should Have Wires With Extra Shaft Support Also N 117 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 53: Ptca Guide Wire Having Polymer Jacket, Composite Core And Jointless Distal Spring Coil N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Composite Core With Actone Inside N• Should Have A Non-Tapering Distal Tip N• Should Have A Polymer Jacket N• Should Have Hydrophilic Slip-Coat Coating Over The Distal Wire N• Should Have Tip Load Of 0.8 Gm N 118 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 54: Ptca Guide Wire Having Composite Core And Jointless Distal Spring Coil And Very Low Tip Load N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Composite Core With Actone Inside N• Should Have A Non-Tapering Distal Tip N• Should Have Hydrophilic Slip-Coat Coating Over The Distal Wire N• Should Have Tip Load Of 0.3 Gm N• Should Have Wires With Routine And Exchange Length N 119 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 55: Ptca Guide Wire Having Polymer Sleeve And Jointless Distal Spring Coil N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Non-Tapering Distal Tip N• Should Have A Polymer Sleeve N• Should Have Hydrophilic Slip-Coat Coating N• Should Have Wires With Tip Load Between 0.8-1.0 Gm N 120 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 56: Ptca Guide Wire Having Polymer Sleeve, Jointless Distal Spring Coil And Tapering Tip N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Core To Tip Design N• Should Have A Tapering Distal Tip To 0.009 Inch N• Should Have A Polymer Sleeve Or Jacket N• Should Have Hydrophilic Slip-Coat Coating N• Should Have Tip Load Between 0.8-1.0 Gm N 121 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 57: Ptca Guide Wire Having Polymer Sleeve, Jointless Distal Spring Coil And Tapering Tip N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Composite Core With Actone Inside N• Should Have A Tapering Distal Tip To 0.010 Inch N• Should Have A Polymer Sleeve Or Jacket N• Should Have Hydrophilic Slip-Coat Coating N• Should Have Wires With Tip Loads Of 0.6 And 1.0 Gm N 122 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 58: Ptca Guide Wire Having Composite Core And Jointless Distal Spring Coil Dedicated For Cto Lesions N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Composite Core With Actone Inside N• Should Have A Micro-Cone Tip Profile And Pre-Shaped Tip N• Should Have Hydrophilic Slip-Coat Coating N• Should Have Varying Wires With Tapering Distal Tip Of 0.010, 0.011 And 0.012 Inches N• Should Have Wires With Tip Loads Of 1.7, 3.5 And 4.5 Gms For Wires With Distal Tip Loads Of 0.010, 0.011 And 0.012 Inches, Respectively N 123 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 59: Ptca Guide Wire Having Composite Core And Jointless Distal Spring Coil Dedicated For Chronic Total Occlusion N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Composite Core With Actone Inside N• Should Have A Micro-Cone Tip Profile And Pre-Shaped Tip N• Should Have Hydrophilic Slip-Coat Coating N• Should Have Varying Wires With Tapering Distal Tip Of 0.011 And 0.012 Inches N• Should Have Wires With Tip Loads Of 2.0, 4.0 And 6.0 Gms For Wires With Distal Tip Loads Of 0.011, 0.012 And 0.012 Inches, Respectively N 124 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 60: Ptca Guide Wire, Non-Tapering, For Chronic Total Occlusion With Distal Spring Coil And Hydrophobic Coating N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Core To Tip Design N• Should Have A Non-Tapering Distal Tip N• Should Have Wires Available In The Tip Loads Of 3, 4.5, 6, 9, 12 Gms N• Should Have Distal Hydrophobic Coating N• Should Not Have Any Polymeric Covering N• The Distal Radio-Opaque Portion Of Wire Should Be 11 Cm N 125 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 61: Special Ptca Guide Wire, Non-Tapering For Chronic Total Occlusion With Distal Spring Coil And Hyrophilic Coating N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Core To Tip Design N• Should Have A Non-Tapering Distal Tip N• Should Have Wires Available In The Tip Load Of 3 Gms N• Should Have Hydrophilic Slip-Coat Coating N• Should Not Have Any Polymeric Covering N• The Distal Radio-Opaque Portion Of Wire Should Be 11 Cm N 126 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 62: Ptca Guide Wire, Tapering To 0.009 Inch Distally Dedicated For Chronic Total Occlusion N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Core To Tip Design N• Should Have A Distal Tip Tapering To 0.009 Inch N• Should Be Available In Distal Tip Load Of 9 And 12 Gms N• The Distal Radio-Opaque Portion Of Wire Should Be 20 Cm N• Should Have Variants With Wires Having Either Hydrophilic Slip-Coat Coating Or Hydrophobic Silicone Coating N• Should Not Have Any Polymeric Covering N 127 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 63: Ptca Guide Wire, Tapering To 0.008 Inch Distally Dedicated For Chronic Total Occlusion N• Should Have One Piece Core Wire With Jointless Distal Spring Coil N• Should Have A Core To Tip Design N• Should Have A Distal Tip Tapering To 0.008 Inch N• Should Be Available In Distal Tip Load Of 20 Gms N• The Distal Radio-Opaque Portion Of Wire Should Be 17 Cm N• Should Have Hydrophilic Slip-Coat Coating N• Should Not Have Any Polymeric Covering N 128 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 64: Special 0.010 Inch Ptca Guide Wire Dedicated For Externalization During Retrograde Cto N• Should Have A Core To Tip Design N• Should Have A Wire Length Of 330 Cm N• Should Have A Wire Outer Diameter Of 0.010 Inch N• Should Be Available In Distal Tip Load Of 3.0 Gm N• Should Have Distal Hydrophilic And Proximal Hydrophobic Coating N• Should Not Have Any Polymeric Covering N 129 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 65: Ptca Guide Wire Having Double Core Design Having Stainless Steel And Nitinol N• Should Have A Double Core Design With Proximal Stainless Steel And Distal Nitinol N• Should Have A Shaping Ribbon Wire Tip Style N• Should Have A Double Coil Wire Tip N• Should Be Available In Standard And Exchange Lengths N• Should Be Available In Variants Having Hydro-Track Or Propel Coating N• Should Have Variants With Different Shaft Support N 130 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 66: Ptca Guide Wire Having Stainless Steel Core Having Coaxial Design N• Should Have A Co-Axial, Stainless Steel Core Having Accu-Core Technology N• Should Have A Round Core-To-Tip Style N• Should Be Available In Variants Having Hydro-Track Or Propel Coating N• Should Be Available In Standard And Exchange Lengths N 131 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 67: Ptca Guide Wire Having Stainless Steel Core And Coaxial Design Dedicated For Chronic Total Occlusion N• Should Have A Co-Axial, Stainless Steel Core Having Accu-Core Technology N• Should Have A Round Core-To-Tip Style N• Should Be Available In Variants Having Hydro-Track Or Propel Coating N• Should Be Available In Variants Having Different Tip Loads Of 3, 6, 9, 12 And 15 Gms N• Should Be Available In Non-Tapering For Tip Load 3, 6 Gms Variants; And Tapering Distal Tip To 0.009 Inches For Tip Loads Of 9, 12, 15 Gms Variants N 132 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 68: Ptca Guide Wire With Tip Made Up Of Multiple Stiff And Flexible Components N• Tip Should Have Slip-Coat Hydrophilic Coating N 133 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 69: Ptca Guide Wire, Non-Tapering, For Chronic Total Occlusion With Super Elastic Nitinol Alloy Core N• Should Be Of 0.014-Inch Diameter, Non-Tapering Distal Tip N• Should Have Polyurethane Distal Tip N• Should Have “M-Coat” For Hydrophilic Coating N 134 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 70: Tapering Ptca Guide Wire, Tapering, 0.010 Inch Distal Tip Dedicated For Chronic Total Occlusion N• Should Be Of 0.014-Inch Diameter N• Should Have A Tapering Distal Tip To 0.010 Inch N• Should Have A Hydro Coat Hydrophilic Coating N• Should Be Available In Variable Distal Tip Load N 135 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 71: Ptca Guide Wire Having Coaxial Spring Design Dedicated For Chronic Total Occlusion N• Should Be Available In Variable Distal Tip Loads N• Should Be Available In Tip Loads : 3, 6, 9, 12 And 15 Gms N• Should Have Either Hydrophilic Or Silicone Coating N• Should Have Co-Axial Spring Design N• The Distal Radio-Opaque Portion Of Wire Should Be Less Than 10 Cm N 136 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 72: Ptca Guide Wire With Bidirectional Deflectable Distal Tip 137 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 73: Extension ( Doc ) Wire For Approved Regular Length Ptca Guide Wires As Quoted In This Tender 138 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 74: Ptca Guide Wire Securing Device N• Should Have Tapering Slits To Secure The Guide Wires For Single Operator Procedure N• Should Allow Controlled Micro-Movement Of Catheters And Wires N• Device Should Have Features To Secure Firmly In The Operative Field N 139 Group B4 Percutaneous Transluminal Coronary Angioplasty- Ptca Guidewires Nitem No. 75: Ptca Guide Wire Docking Device N• Should Allow Easy Introduction Of Ptca Guide Wire Into Catheters And Atherectomy Burrs N• Docking Device Should Have Features To Secure Firmly In The Operative Field N• Should Have Slits To Hold The Guide Wire For Single Operator Procedure N 140 Group B5 Special Devices For Chronic Total Occlusion Angioplasty Nitem No. 1: Ptca Catheter With Deflectable Distal End To Guide The Direction Of Ptca Guide Wire 141 Group B5 Special Devices For Chronic Total Occlusion Angioplasty Nitem No. 2: Micro-Channel Dilator Catheter With Tapered Soft Tip And Hydrophilic Shaft N• Should Have Shaft With Od Of 2.6 Fr Or Lower N• Should Be Available In 130 To 150 Cm For Antegrade And Retrograde Approach N 142 Group B5 Special Devices For Chronic Total Occlusion Angioplasty Nitem No. 3: Coronary Microcatheter With Tapered Tip For Cto Intervention N• Must Have A Distal Tip Od Of 1.8 Fr Or Lower N• Should Be Available In 130 To 150 Cm In Length For Both Antegrade And Retrograde Approach N 143 Group B5 Special Devices For Chronic Total Occlusion Angioplasty Nitem No. 4: Special Microcatheter For Embolisation Allowing A Coaxial Guidewire Of 0.021” Diameter N 144 Group B5 Special Devices For Chronic Total Occlusion Angioplasty Nitem No. 5: Special Coronary Microcatheter For Cto Having Wire Braiding For Transmission Of Rotational Movements For Cto Penetration N 145 Group B5 Special Devices For Chronic Total Occlusion Angioplasty Nitem No. 6: Special Coronary Microcatheter For Cto Having Dual Wire Braiding For Efficient Transmission Of Rotational Movements For Cto Penetration N 146 Group B5 Special Devices For Chronic Total Occlusion Angioplasty Nitem No. 7: Dual Lumen Microcatheter For Side Branch Access 147 Group B5 Special Devices For Chronic Total Occlusion Angioplasty Nitem No. 8: Special Microcatheter With Very Low Entry And Crossing Profile N• Must Have A Distal Tip Entry Profile Of 1.4 Fr Or Lower And Crossing Profile Of 2.1 Fr Or Lower N• Must Be Available In 130 To 150 Cm Length For Both Antegrade And Retrograde Approach N 148 Group B5 Special Devices For Chronic Total Occlusion Angioplasty Nitem No. 9: Special Angled Tip Coronary Microcatheter For Cto N• Must Be Available In Various Angles ( 45O, 90O And 120O ) N• Should Be Available In 130 To 150 Cm Length For Both Antegrade And Retrograde Approach N• Distal Od Should Be 2.4 Fr Or Lower N 149 Group B5 Special Devices For Chronic Total Occlusion Angioplasty Nitem No. 10: Special Crossing Catheter For Cto For Blunt Sub-Intimal Dissection 150 Group B5 Special Devices For Chronic Total Occlusion Angioplasty Nitem No. 11: Special Luminal Re-Entry System For Cto With Special Self Re-Aligning Balloon With 2 Exit Ports 151 Group B6 Ptca Balloons Nitem No. 1: Ptca Balloon ( Semi-Compliant ) – Manufactured In India N• Monorail ( Rapid Exchange ) Balloons N• Should Be Available In All Sizes And Lengths N N 152 Group B6 Ptca Balloons Nitem No. 2: Ptca Balloon ( Semi-Compliant ) - Ce Marked N• Monorail ( Rapid Exchange ) Balloons N• Should Be Available In All Sizes And Lengths N N 153 Group B6 Ptca Balloons Nitem No. 3: Ptca Balloon ( Semi-Compliant ) - Us Fda Approved N• Monorail ( Rapid Exchange ) Balloons N• Should Be Available In All Sizes And Lengths N N 154 Group B6 Ptca Balloons Nitem No. 4: Ptca Balloon ( Semi-Compliant ) – Manufactured In India N• Over-The-Wire ( Otw ) Balloons N• Should Be Available In All Sizes And Lengths N N 155 Group B6 Ptca Balloons Nitem No. 5: Ptca Balloon ( Semi-Compliant ) - Ce Marked N• Over-The-Wire ( Otw ) Balloons N• Should Be Available In All Sizes And Lengths N N 156 Group B6 Ptca Balloons Nitem No. 6: Ptca Balloon ( Semi-Compliant ) - Us Fda Approved N• Over-The-Wire ( Otw ) Balloons N• Should Be Available In All Sizes And Lengths N N 157 Group B6 Ptca Balloons Nitem No. 7: Ptca Balloon ( Non-Compliant ) - Manufactured In India N• Should Be Available In All Sizes, Variable Lengths N• Should Have A Very High Rated Burst Pressure N N 158 Group B6 Ptca Balloons Nitem No. 8: Ptca Balloon ( Non-Compliant ) - Ce Marked N• Should Be Available In All Sizes, Variable Lengths N• Should Have A Very High Rated Burst Pressure N N 159 Group B6 Ptca Balloons Nitem No. 9: Ptca Balloon ( Non-Compliant ) - Us Fda Approved N• Should Be Available In All Sizes, Variable Lengths N• Should Have A Very High Rated Burst Pressure N N 160 Group B6 Ptca Balloons Nitem No. 10: Ptca Balloon Catheter For Complex Coronary Interventions – Manufactured In India N• Should Be Available In Both Semi-Compliant And Non-Compliant Platforms N• Should Have Very Low Crossing Profile So As To Facilitate Complex Ptca Procedure N N 161 Group B6 Ptca Balloons Nitem No. 11: Ptca Balloon Catheter For Complex Coronary Interventions – Ce Marked N• Should Be Available In Both Semi-Compliant And Non-Compliant Platforms N• Should Have Very Low Crossing Profile So As To Facilitate Complex Ptca Procedure N N 162 Group B6 Ptca Balloons Nitem No. 12: Ptca Balloon Catheter For Complex Coronary Interventions – Us Fda Approved N• Should Be Available In Both Semi-Compliant And Non-Compliant Platforms N• Should Have Very Low Crossing Profile So As To Facilitate Complex Ptca Procedure N N 163 Group B6 Ptca Balloons Nitem No. 13: Special Ptca Balloon ( Non-Compliant ) N• Should Have Very High Rated Burst Pressure ( More Than 30 Mmhg ) N• Should Be Available In All Sizes, Variable Lengths N 164 Group B6 Ptca Balloons Nitem No. 14: Special Ptca Balloon ( Non-Compliant ) N• Should Have Very High Rated Burst Pressure ( More Than 40 Mmhg ) N• Should Be Available In All Sizes, Variable Lengths N N 165 Group B6 Ptca Balloons Nitem No. 15: Special Ptca Balloon ( Steady Compliant ) N• Semi-Compliant At Low Pressure And Non-Compliant At High Pressure N N 166 Group B6 Ptca Balloons Nitem No. 16: Special Ptca Balloon Catheter With Very Low Crossing Profile N• Must Have Crossing Balloon Profile Of = 0.021 Inches N N 167 Group B6 Ptca Balloons Nitem No. 17: Special Ptca Balloon For Retrograde Approach Of Cto N• Should Be Available In Regular Lengths For Retrograde Approach N• Should Be Available As Over The Wire ( Otw ) N• Available In All Sizes And Lengths N 168 Group B6 Ptca Balloons Nitem No. 18: Special Ptca Balloon With Biflex Tip For Complex Procedures N 169 Group B6 Ptca Balloons Nitem No. 19: Special Non-Compliant Ptca Balloon For Complex Coronary Intervention N• Must Have Specially Designed Triple Layer Of Ptca Balloon For Sustaining High Pressures N• Must Have A Lesion Entry Profile Of = 0.43 Mm N• The Balloon Must Have A Hydrophilic Coating N• The Balloon Must Be Available In All The Sizes 2.0, 2.25, 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4.0, 4.5 And 5.0 Mm N• The Balloon Must Be Available In 6, 8, 12 And 15 Mm Lengths For All The Sizes Between 1-5 Mm N• The Balloon Diameter Between 2.0-4.0 Mm Must Also Be Available In 20 Mm Length N• The Balloons With Diameters Of 2.5, 3.0 And 3.5 Mm Must Also Be Available In Long Lengths Of 25 And 30 Mm. N N 170 Group B6 Ptca Balloons Nitem No. 20: Special Ptca Balloon For Retrograde Approach Of Cto N• Should Be Available In Long Lengths For Retrograde Approach N• Should Be Available As Over The Wire ( Otw ) N• Available In All Sizes And Lengths N N 171 Group B7 Special Ptca Balloons Nitem No. 1: Special Large Ptca Balloons Of 4 Mm To 4.5 Mm N• Must Be Available In Both 4 And 4.5 Mm Diameters And Should Be Available In Variable Balloon Lengths N 172 Group B7 Special Ptca Balloons Nitem No. 2: Special Large Ptca Balloons Of 5 Mm To 5.5 Mm N• Must Be Available In Both 5 And 5.5 Mm Diameters And Should Be Available In Variable Balloon Lengths N 173 Group B7 Special Ptca Balloons Nitem No. 3: Special Ptca Balloon Catheter Of 1.20 - 1.25 Mm N• Should Be Available In Variable Balloon Lengths N 174 Group B7 Special Ptca Balloons Nitem No. 4: Special Ptca Balloon Catheter Of 1.10 Mm N• Should Be Available In Variable Balloon Lengths N 175 Group B7 Special Ptca Balloons Nitem No. 5: Special Ptca Balloon Catheter Of 1.00 Mm N• Should Be Available In Variable Balloon Lengths N 176 Group B7 Special Ptca Balloons Nitem No. 6: Special Ptca Balloon Catheter Of Less Than 1.00 Mm N• Should Be Available In Variable Balloon Lengths N 177 Group B7 Special Ptca Balloons Nitem No. 7: Special Non-Compliant Ptca Balloon Catheter Of Less Than 1.00 Mm N• Should Be Available In Variable Balloon Lengths N 178 Group B7 Special Ptca Balloons Nitem No. 8: Special Zero Length Ptca Balloon Catheter For Focal Dilatation N• Should Be Available In Variable Balloon Diameters N 179 Group B7 Special Ptca Balloons Nitem No. 9: Over The Wire ( Otw ) Coaxial Ptca Balloon ( Semi-Compliant ) N• Should Be Available In All Sizes And Lengths N 180 Group B7 Special Ptca Balloons Nitem No. 10: Special Over The Wire ( Otw ) Ptca Balloon Dedicated For Alcohol Septal Ablation For Hypertrophic Obstructive Cardiomyopathy ( Hocm ) 181 Group B7 Special Ptca Balloons Nitem No. 11: Special Ptca Balloon For Crossing Cto N• Should Be Available In = 1.25 Mm Diameter N• Should Be Ultrashort With Balloon Length = 6 Mm N• Should Have Low Crossing Profile With No Balloon Fold At Distal End N 182 Group B7 Special Ptca Balloons Nitem No. 12: Special Ptca Balloon For Chronic Total Occlusion ( Cto ) Interventions N• Must Be Available In Sizes Between 1 And 4 Mm Diameter N• The Balloon Must Have All The Sizes Of 1, 1.25, 1.5, 2.0, 2.25, 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4.0 Mm N• Must Have A Low Entry Profile Of = 0.016 Inch ( 0.41 Mm ) For 1.0-1.5 Mm Balloons N• The Balloon Must Have A Durable Hydrophilic Coating N• The Balloon Must Have A Low Crossing Profile Of 0.58 Mm For Balloons 1-4 Mm. N• The Balloon Must Be Available In Sizes 10, 15, 20 Mm For Balloon Diameters Of 1.25-4.0 Mm N• The 1.0 Mm Balloon Must Be Available In 5 Mm Length N• The Balloons Of Diameters 2.0, 2.5, 3.0, 3.5 Must Also Have Long Lengths Of 30 Mmm And 40 Mm N• The Balloon Must Have A Stainless Steel Tapered Core Wire Design N 183 Group B7 Special Ptca Balloons Nitem No. 13: Dedicated Ptca Bifurcation Balloon N• Should Have Double Rapid Exchange Design N• Single Simultaneous Inflation For Both Main Vessel And Side Branch N• Should Be Compatible With 6 Fr. Guiding Catheter N 184 Group B7 Special Ptca Balloons Nitem No. 14: Drug Eluting Balloon For Ptca Eluting Paclitaxel 185 Group B7 Special Ptca Balloons Nitem No. 15: Drug Eluting Balloon For Ptca Eluting Any Drug Other Than Paclitaxel 186 Group B7 Special Ptca Balloons Nitem No. 16: Dual Access Catheter For Ptca N• Should Have Lumen For Rapid Exchange As Well As Over The Wire ( Otw ) In Same Device N• Should Allow Passage Of Additional Wire, Contrast Or Drugs From The Otw Lumen While Retaining The Rapid Exchange Lumen In Place N 187 Group B7 Special Ptca Balloons Nitem No. 17: Coronary Infusion / Drug Delivery Catheter N 188 Group B7 Special Ptca Balloons Nitem No. 18: Scoring Balloon Catheter For Ptca N 189 Group B7 Special Ptca Balloons Nitem No. 19: Scoring Balloon Catheter For Ptca With A Low Crossing Profile Of 0.032 Inch Or Less N 190 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 1: Rotational Atherectomy System With Pre-Connected Rotablation Burr Attached To Rotablation Advancer – Compatible With The Machine Available In Cath Lab At Aiims, New Delhi N 191 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 2: Rotational Atherectomy Burr - Compatible With The Machine Available In Cath Lab At Aiims, New Delhi N• Should Be Available In All The Standard Sizes N N 192 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 3: Rotational Atherectomy Advancer - Compatible With The Machine Available In Cath Lab At Aiims, New Delhi N 193 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 4: Rotational Atherectomy Guidewire - Compatible With The Rotational Atherectomy System Available In Cath Lab At Aiims, New Delhi N 194 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 5: Rotaglide Lubricant For Rotational Atherectomy N 195 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 6: Special Atherectomy Device For Calcific Coronary Lesions Performing Bidirectional Sanding Of Calcium N 196 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 7: Excimer Laser Coronary Atherectomy Catheter For Complex Coronary Interventions – Compatible With Machine Available At Aiims Cath Lab N• Should Be Available In All The Standard Sizes ( Diameters ) N• Should Be Available In Both Concentric And Eccentric Array Fibres N N 197 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 8: Cutting Balloon For Ptca Having Microsurgical Atherotomes ( Blades ) N• Should Be Available In Standard Balloon Diameters And Lengths N N 198 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 9: Cutting Balloon For Ptca- Manufactured In India N• Should Be Available In Standard Balloon Diameters And Lengths N N 199 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 10: Cutting Balloon For Ptca-Ce Marked N• Should Be Available In Standard Balloon Diameters And Lengths N N 200 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 11: Cutting Balloon For Ptca-Us Fda Approved N• Should Be Available In Standard Balloon Diameters And Lengths N N 201 Group B8 Cutting Balloon, Rotabalation Device And Accessories Nitem No. 12: Shockwave Intravascular Lithotripsy Catheter N• Should Be Available In Standard Balloon Diameters And Lengths N N 202 Group B9 Microcatheter, Ffr Wire And Ivus Catheter : Nitem No. 1: Coronary Microcatheter – Manufactured In India 203 Group B9 Microcatheter, Ffr Wire And Ivus Catheter : Nitem No. 2: Coronary Microcatheter – Ce Marked 204 Group B9 Microcatheter, Ffr Wire And Ivus Catheter : Nitem No. 3: Coronary Microcatheter – Us Fda Approved 205 Group B9 Microcatheter, Ffr Wire And Ivus Catheter : Nitem No. 4: Intracoronary Presssure Wire ( Ffr ) For Ptca - Compatible With The System Available In Aiims Cath Lab 206 Group B9 Microcatheter, Ffr Wire And Ivus Catheter : Nitem No. 5: Intracoronary Pressure Wire ( Ffr ) For Ptca With Wireless Connectivity – Compatible With The System Available At Aiims Cath Lab 207 Group B9 Microcatheter, Ffr Wire And Ivus Catheter : Nitem No. 6: Intracoronary Presssure Wire ( Ifr ) For Ptca - Compatible With The System Available In Aiims Cath Lab 208 Group B9 Microcatheter, Ffr Wire And Ivus Catheter : Nitem No. 7: Intracoronary Presssure Wire ( Rfr ) For Ptca - Compatible With The System Available In Aiims Cath Lab 209 Group B9 Microcatheter, Ffr Wire And Ivus Catheter : Nitem No. 8: Ivus Catheter With Phased Array Transducer For Coronary Interventions - Compatible With The Machine Available In Aiims Cath Lab 210 Group B9 Microcatheter, Ffr Wire And Ivus Catheter : Nitem No. 9: High Resolution Ivus Catheter With Operating Frequency 40 Mhz With Mechanical Transducer For Coronary Intervention – Compatible With Machine Available At Aiims Cath Lab 211 Group B9 Microcatheter, Ffr Wire And Ivus Catheter : Nitem No. 10: High Resolution Ivus Catheter With Operating Frequency 60 Mhz With Mechanical Transducer For Coronary Intervention – Compatible With Machine Available At Aiims Cath Lab 212 Group B9 Microcatheter, Ffr Wire And Ivus Catheter : Nitem No. 11: Oct Catheter For Coronary Interventions - Compatible With The Machine Available In Aiims, New Delhi Cath Lab 213 Group B10 Embolic Protection And Thrombosuctuion Devices Nitem No. 1: Embolic Protection Device ( Epd ) For Ptca: Filter Technology- Manufactured In India 214 Group B10 Embolic Protection And Thrombosuctuion Devices Nitem No. 2: Embolic Protection Device ( Epd ) For Ptca: Filter Technology- Ce Marked N 215 Group B10 Embolic Protection And Thrombosuctuion Devices Nitem No. 3: Embolic Protection Device ( Epd ) For Ptca: Filter Technology- Us Fda Approved N 216 Group B10 Embolic Protection And Thrombosuctuion Devices Nitem No. 4: Manual Thrombus Aspiration Catheter For Ptca – Manufactured In India N 217 Group B10 Embolic Protection And Thrombosuctuion Devices Nitem No. 5: Manual Thrombus Aspiration Catheter For Ptca - Ce Marked N 218 Group B10 Embolic Protection And Thrombosuctuion Devices Nitem No. 6: Manual Thrombus Aspiration Catheter For Ptca- Us Fda Approved N 219 Group B10 Embolic Protection And Thrombosuctuion Devices Nitem No. 7: Special Large Lumen Thrombus Aspiration Catheter N• Must Have A Id Of 0.043” Or Higher At The Distal Tip N• Must Be Compatible With 6 Fr And 7 Fr Guide Catheter N• Should Have Forward Facing Tip For More Efficient Thrombosuction N• Should Provide An Aspiration Rate Of At Least 52 Cc / Min N• Should Be Provided With A Kit Of At Least 2 Aspiration Syringes, Extension Tubing With Stop Cock And Filter Baskets N N 220 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 1: Iabp Catheter- Manufactured In India, Compatible With The Available Machine In Cath Lab 221 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 2: Iabp Catheter - Ce Marked, Compatible With The Available Machine In Cath Lab 222 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 3: Iabp Catheter- Us Fda Approved, Compatible With The Available Machine In Cath Lab 223 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 4: Special Iabp Catheter Having Fiberoptic Technology, Compatible With The Available Machine In Cath Lab 224 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 5: Act Tubes N• Disposable Act Tubes Compatible With Existing Machines At Aiims N• Should Meet Highest Medical Industrial Standards N• Quality Certification Should Be Provided From Authorized Agencies N 225 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 6: Arterial ( Femoral ) Puncure Closure Device - Intravascular Bioabsorbable Polymer Based Device 226 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 7: Arterial ( Femoral ) Puncure Closure Device - Extravascular Clip Based Device 227 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 8: Arterial ( Femoral ) Puncure Closure Device - Extravascular Sealant Based Device 228 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 9: Arterial ( Femoral ) Puncure Closure Device - Suture Based Device 229 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 10: Special Large Bore Vascular Access ( Up To 10 French At Least ) Closure Device – Suture Based Device 230 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 11: Special Large Bore Vascular Access ( 10-22 French ) Closure Device – Collagen Based Device 231 Group B11 Iabp Catheters And Femoral Puncture Closure Devices Nitem No. 12: Special Large Bore Vascular Access ( 10-20 French ) Closure Device – Patch Based Or Membrane Based 232 Group B12 Hemostasis Devices Nitem No. 1: Arterial Puncure Sealing Device Using Extravascular Sealent Or Coagulant For Use Following Transfemoral Intervention 233 Group B12 Hemostasis Devices Nitem No. 2: Pharmacological Hemostasis- Liquid Based Procoagulant Solution For Use Following Transfemoral Intervention 234 Group B12 Hemostasis Devices Nitem No. 3: Pharmacological Hemostasis - Topical Dry Pad / Bandage Based Mechanism For Use Following Transfemoral Intervention 235 Group B12 Hemostasis Devices Nitem No. 4: Femoral Compression Devices - Disc / Dome Based Compression 236 Group B12 Hemostasis Devices Nitem No. 5: Discs / Domes Of Femoral Compression Devices 237 Group B12 Hemostasis Devices Nitem No. 6: Femoral Compression Devices - Inflatable Balloon Based Compression 238 Group B12 Hemostasis Devices Nitem No. 7: Disposable Femoral Compression Devices - Inflatable Balloon Based Compression 239 Group B12 Hemostasis Devices Nitem No. 8: Handheld External Femoral Compression Assisting Device 240 Group B12 Hemostasis Devices Nitem No. 9: Radial Artery Compressor - Balloon Based 241 Group B12 Hemostasis Devices Nitem No. 10: Special Radial Artery Compressor - Balloon Based With Double Balloon Technology 242 Group B12 Hemostasis Devices Nitem No. 11: Radial Artery Compressor - Strap Based

Key Value

Document Fees
Refer document
EMD
INR 100000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Purchase of Consumable Items on 2 year rate contract basis Group B.
Sl. No. Item Description Item Code / Make Quantity Units
1 1.01 GROUP B1 PTCA ACCESSORIES\nItem No. 1: PTCA INFLATION DEVICE- ANALOG DISPLAY WITH MAXIMUM INFLATION PRESSURE UP TO 30 ATM\n• Efficient locking system to maintain high pressure\n• Rapid inflation and deflation\n• Clear barrel for easy visualization of de-bubbling\n• Luminescent analog pressure gauge with scale of 0 to 30 atm \n• Ergonomic and user-friendly handheld design\n\n item1 1 pices
2 2 GROUP B1 PTCA ACCESSORIES\nItem No. 2: PTCA INFLATION DEVICE- ANALOG DISPLAY WITH MAXIMUM INFLATION PRESSURE ONLY UP TO 15-20 ATM\n• Efficient locking system to maintain high pressure\n• Rapid inflation and deflation\n• Clear barrel for easy visualization of de-bubbling\n• Luminescent analog pressure gauge with scale of 0 to 20 atm \n• Ergonomic and user-friendly handheld design\n\n item2 1 pices
3 3 GROUP B1 PTCA ACCESSORIES\nItem No. 3: PTCA INFLATION DEVICE- ANALOG DISPLAY WITH MAXIMUM INFLATION PRESSURE ONLY UP TO 10-15 ATM\n• Efficient locking system to maintain high pressure\n• Rapid inflation and deflation\n• Clear barrel for easy visualization of de-bubbling\n• Luminescent analog pressure gauge with scale of 0 to 15 atm \n• Ergonomic and user-friendly handheld design\n\n item3 1 pices
4 4 GROUP B1 PTCA ACCESSORIES\nItem No. 4: PTCA INFLATION DEVICE- ANALOG DISPLAY WITH MAXIMUM INFLATION PRESSURE BEYOND 30 ATM\n• Efficient locking system to maintain high pressure\n• Rapid inflation and deflation\n• Clear barrel for easy visualization of de-bubbling\n• Luminescent analog pressure gauge having maximum inflation pressure beyond 30 atm\n• Ergonomic and user-friendly handheld design\n\n item4 1 pices
5 5 GROUP B1 PTCA ACCESSORIES\nItem No. 5: PTCA INFLATION DEVICE- DIGITAL DISPLAY\n• Efficient locking system to maintain high pressure\n• Rapid inflation and deflation\n• Clear barrel for easy visualization of de-bubbling\n• Ergonomic and user-friendly handheld design\n item5 1 pices
6 6 GROUP B1 PTCA ACCESSORIES\nItem No. 6: Y CONNECTOR FOR PTCA – ROTATION TYPE\n• Should accept catheters up to 0.096 inch\n• Large thumb wheel for easy maneuverability\n• Luer connector at the guiding catheter end\n• Rotating adapter at the guiding catheter end\n• Should fit comfortably in hand and can be manipulated using single hand\n item6 1 pices
7 7 GROUP B1 PTCA ACCESSORIES\nItem No. 7: LARGE BORE Y CONNECTOR FOR PTCA – ROTATION TYPE\n• Should accept catheters up to 0.115 inch\n• Large thumb wheel for easy maneuverability\n• Luer connector at the guiding catheter end\n• Rotating adapter at the guiding catheter end\n• Should fit comfortably in hand and can be manipulated using single hand\n item7 1 pices
8 8 GROUP B1 PTCA ACCESSORIES\nItem No. 8: Y CONNECTOR FOR PTCA – PUSH AND PULL TYPE\n• Should accept catheters up to 0.096 inch\n• Luer connector at the guiding catheter end\n• Rotating adapter at the guiding catheter end\n• Should have bleed back safety mechanism\n• Stepwise control for open, semi-open and closed position\n• Should fit comfortably in hand and can be manipulated using single hand\n item8 1 pices
9 9 GROUP B1 PTCA ACCESSORIES\nItem No. 9: LARGE BORE Y CONNECTOR FOR PTCA – PUSH AND PULL TYPE\n• Should accept catheters up to 0.115 inch\n• Luer connector at the guiding catheter end\n• Rotating adapter at the guiding catheter end\n• Should have bleed back safety mechanism\n• Stepwise control for open, semi-open and closed position\n• Should fit comfortably in hand and can be manipulated using single hand\n item9 1 pices
10 10 GROUP B1 PTCA ACCESSORIES\nItem No.10: Y CONNECTOR WITH EXTENSION TUBING (HAEMOSTATIC Y-CONNECTOR WITH EXTENSION TUBING) FOR PTCA- ROTATING MECHANISM \n• Should accept catheters up to 0.115 inch\n• Should have at least 12-inch-long, large lumen high pressure extension tubing\n• Should have an attached 3-way connector to the extension tubing\n• Large thumb wheel for easy maneuverability \n• Luer connector at the guiding catheter end\n• Rotating adapter at the guiding catheter end\n item10 1 pices
11 11 GROUP B1 PTCA ACCESSORIES\nItem No. 11: Y CONNECTOR WITH EXTENSION TUBING (HAEMOSTATIC Y-CONNECTOR WITH EXTENSION TUBING) FOR PTCA- PUSH MECHANISM \n• Should accept catheters up to 0.0.096 inch\n• Should have at least 12-inch-long, large lumen high pressure extension tubing\n• Should have an attached 3-way connector to the extension tubing\n• Large thumb wheel for easy maneuverability \n• Luer connector at the guiding catheter end\n• Rotating adapter at the guiding catheter end\n item11 1 pices
12 12 GROUP B1 PTCA ACCESSORIES\nItem No. 12: HAEMOSTATIC DOUBLE VALVE Y-CONNECTOR FOR BIFURCATION PTCA \n• Should accept catheters up to 0.115 inch\n• Two separate ports for insertion of interventional devices\n• Luer connector at the guiding catheter end\n• Rotating adapter at the guiding catheter end\n item12 1 pices
13 13 GROUP B1 PTCA ACCESSORIES\nItem No. 13: VERY LARGE BORE HAEMOSTATIC Y-CONNECTOR\n• Should accept catheters up to 0.170 inch (13 Fr. Size) \n• Large thumb wheel for easy maneuverability \n• Luer connector at the guiding catheter end\n• Rotating adapter at the guiding catheter end item13 1 pices
14 14 GROUP B1 PTCA ACCESSORIES\nItem No. 14: EXTREMELY LARGE BORE HAEMOSTATIC Y-CONNECTOR\n• Should accept catheters up to 0.24 inch (18 Fr. Size) \n• Large thumb wheel for easy maneuverability \n• Luer connector at the guiding catheter end\n• Rotating adapter at the guiding catheter end\n item14 1 pices
15 15 GROUP B1 PTCA ACCESSORIES\nItem No. 15: GUIDE WIRE TORQUER FOR CORONARY INTERVENTION\n• Should hold guide wires from 0.009-0.018 inches \n• Ergonomic and user-friendly design\n item15 1 pices
16 16 GROUP B1 PTCA ACCESSORIES\nItem No. 16: GUIDE WIRE TORQUER FOR PERIPHERAL/STRUCTURAL INTERVENTION\n• Should hold guide wires from 0.018-0.035 inches \n• Ergonomic and user-friendly design\n item16 1 pices
17 17 GROUP B1 PTCA ACCESSORIES\nItem No. 17: PTCA GUIDE WIRE INSERTION TOOL\n• 20 G size\n• 10 -12 cm long metallic shaft\n• Should allow to 0.018-inch guide wire\n item17 1 pices
18 18 GROUP B2 PTCA ACCESSORIES\nItem No. 1: PTCA ACCESSORY KIT CONTAINING\n• One Hemostatic Y connector\n• One PTCA guide wire torquer\n• One PTCA guide wire insertion tool\n item18 1 pices
19 19 GROUP B2 PTCA ACCESSORIES\nItem No. 2: PTCA INFLATION DEVICE WITH ACCESSORY KIT CONTAINING Y CONNECTOR\n• Must have one PTCA inflation device with luminescent analog pressure gauge (up to 30 atm)\n• Must have one Hemostatic Y connector with\n• Must have one PTCA guide wire torquer\n• Must have one PTCA guide wire insertion tool\n• Should be able to provide inflation device with both maximum inflation pressures up to 20 atm only and 30 atm only\n• Should be able to provide the Y connector with choice of rotation lock, push-pull lock or dual valve mechanism\n• Should be able to provide Y connector in lumen sizes up to 0.115 inch\n\n item19 1 pices
20 20 GROUP B2 PTCA ACCESSORIES\nItem No. 3: PTCA INFLATION DEVICE WITH ACCESSORY KIT CONTAINING Y CONNECTOR WITH ROTATION LOCK\n• Must have one PTCA inflation device with luminescent analog pressure gauge (up to 30 atm)\n• Must have one Hemostatic Y connector with rotation lock and bore up to 0.096 inch\n• Must have one PTCA guide wire torquer\n• Must have one PTCA guide wire insertion tool\n\n item20 1 pices
21 21 GROUP B2 PTCA ACCESSORIES\nItem No. 4: PTCA INFLATION DEVICE WITH ACCESSORY KIT CONTAINING LARGE BORE Y CONNECTOR WITH ROTATION LOCK\n• Must have one PTCA inflation device with luminescent analog pressure gauge (up to 30 atm)\n• Must have one Hemostatic Y connector with rotation lock and bore up to 0.115 inch\n• Must have one PTCA guide wire torquer\n• Must have one PTCA guide wire insertion tool\n\n item21 1 pices
22 22 GROUP B2 PTCA ACCESSORIES\nItem No. 5: PTCA INFLATION DEVICE WITH ACCESSORY KIT CONTAINING Y CONNECTOR WITH PUSH-PULL LOCK MECHANISM\n• Must have one PTCA inflation device with luminescent analog pressure gauge (up to 30 atm)\n• Must have one Hemostatic Y connector with push-pull lock and bore up to 0.096 inch\n• Must have one PTCA guide wire torquer\n• Must have one PTCA guide wire insertion tool\n\n item22 1 pices
23 23 GROUP B2 PTCA ACCESSORIES\nItem No. 6: PTCA INFLATION DEVICE WITH ACCESSORY KIT CONTAINING Y CONNECTOR\n• Must have one PTCA inflation device with luminescent analog pressure gauge (up to 30 atm)\n• Must have one Hemostatic Y connector with rotation lock and bore up to 0.096 inch\n• Must have one PTCA guide wire torquer\n• Must have one PTCA guide wire insertion tool\n\n item23 1 pices
24 24 GROUP B2 PTCA ACCESSORIES\nItem No. 7: DISPOSABLE PLASTIC STERILE CONTROL SYRINGE FOR ANGIOGRAPHY AND PTCA\n• Clear, glass-like plastic syringe\n• Markings up to 10- 12 ml \n• Single hand palm and finger assisted maneuverability\n• Plunger should have resistance free movement\n• Should have a stopper with 0.5 ml reserve\n• Should be individually packed\n\n item24 1 pices
25 25 GROUP B2 PTCA ACCESSORIES\nItem No. 8: DISPOSABLE PLASTIC STERILE LUER LOCK SYRINGE FOR ANGIOGRAPHY AND PTCA\n• Clear, glass-like medical grade plastic syringe made up of three parts: barrel, plunger and latex piston\n• Markings up to 10 ml \n• Plunger should have resistance free movement\n• Should have Luer lock mechanism for attachment \n• Should be individually packed\n\n item25 1 pices
26 26 GROUP B2 PTCA ACCESSORIES\nItem No. 9: DISPOSABLE PLASTIC STERILE LUER LOCK SYRINGE FOR ANGIOGRAPHY AND PTCA\n• Clear, glass-like medical grade plastic syringe made up of three parts: barrel, plunger and latex piston\n• Markings up to 12 ml \n• Plunger should have resistance free movement\n• Should have Luer lock mechanism for attachment \n• Should be individually packed\n\n item26 1 pices
27 27 GROUP B2 PTCA ACCESSORIES\nItem No. 10: MANIFOLD WITH TWO SIDE PORTS FOR ANGIOGRAPHY AND PTCA\n• Large bore/I.D (at least 0.093 inch) for easy flow of contrast\n• Smooth resistance free uni-direction handle/knob\n• Should have clear body for controlled debubbling\n• Should be available in both block and half-body styles\n• Should take pressures up to 500 psi\n\n item27 1 pices
28 28 GROUP B2 PTCA ACCESSORIES\nItemNo. 11: MANIFOLD WITH THREE SIDE PORTS FOR PTCA \n• Large bore/I.D (at least 0.093 inch) for easy flow of contrast\n• Smooth resistance free uni-direction handle/knob\n• Should have clear body for controlled debubbling\n• Should be available in both block and half-body styles\n• Should take pressures up to 500 psi\n\n item28 1 pices
29 29 GROUP B2 PTCA ACCESSORIES\nItem No. 12: CONNECTOR TUBING (CONNECTING BETWEEN TOUHY BORST AND MANIFOLD)\n• Should be between 25- 50 cm \n• Should have large I.D for easy flow of contrast\n• Should take high pressure \n• Should be flexible\n• Should have male and female hubs\n\n item29 1 pices
30 30 GROUP B2 PTCA ACCESSORIES\nItem No. 13: CONNECTOR TUBING (CONNECTING BETWEEN Y CONNECTOR AND MANIFOLD) WITH ATTACHED THREE-WAY STOP COCK \n• Should be between 20-50 cm long\n• Should have large I.D for easy flow of contrast\n• Should take high pressure \n• Should be flexible\n• Should have attached three-way stopcock at one end\n\n item30 1 pices
31 31 GROUP B2 PTCA ACCESSORIES\nItem No. 14: CONTRAST TUBING (CONNECTING BETWEEN CONTRAST BOTTLE AND MANIFOLD)\n• Should have large I.D for easy flow of contrast\n• Should be flexible\n• Should have flow regulating knobs\n\n item31 1 pices
32 32 GROUP B2 PTCA ACCESSORIES\nItem No. 15: MANIFOLD WITH ATTACHED TUBINGS\n• Two/Three side port manifold\n• One connector tubing for connecting Manifold to Y connector\n• One large bore contrast tubing (with flow regulating knob) for attachment between contrast bottle & manifold side port\n• One Luer lock three-piece disposable syringe having markings up to 10- 12 ml for contrast injection\n\n item32 1 pices
33 33 GROUP B2 PTCA ACCESSORIES\nItem No. 16: PTCA ACCESSORIES KIT: Should contain the following items\n• Hemostatic Y- connector\n• One two/three side-port Manifold\n• One connector tubing for connecting Manifold to Y connector\n• One Luer lock three-piece disposable syringe having markings up to 10- 12 ml for contrast injection\n• One PTCA guide wire insertion needle\n• One PTCA guide wire Torquer\n• One large bore contrast tubing (with flow regulating knob) for attachment between contrast bottle & manifold side port\n• One three way stop cock\n\n item33 1 pices
34 34 GROUP B2 PTCA ACCESSORIES\nItem No. 17: PTCA ACCESSORIES COMBO PACK: Should contain the following items\n• One PTCA inflation device\n• Hemostatic Y- connector\n• One two/three side-port Manifold\n• One connector tubing for connecting Manifold to Y connector\n• One Luer lock three-piece disposable syringe having markings up to 10- 12 ml for contrast injection\n• One PTCA guide wire insertion needle\n• One PTCA guide wire Torquer\n• One large bore contrast tubing (with flow regulating knob) for attachment between contrast bottle & manifold side port\n• One three way stop cock\n\n item34 1 pices
35 35 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 1: PTCA GUIDING CATHETERS OF 6- 7 FRENCH SIZES \n• Must have 6- 7 Fr. guiding catheters \n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and others.\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have soft short tip catheters\n item35 1 pices
36 36 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. ¬¬2: PTCA GUIDING CATHETERS OF 5 FRENCH SIZE \n• Must have 5 Fr. guiding catheters \n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and others.\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have soft short tip catheters\n item36 1 pices
37 37 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. ¬¬3: PTCA GUIDING CATHETERS OF 8 FRENCH SIZES \n• Must have 8 Fr. guiding catheters \n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and others.\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have soft short tip catheters\n item37 1 pices
38 38 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. ¬¬4: SPECIAL LARGE LUMEN PTCA GUIDING CATHETERS OF 6 FRENCH SIZE \n• Must have 6Fr. guiding catheters with I.D of 0.071 inch or more\n• Failure to comply with the specifications will lead to rejection as a whole from this item.\n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and others.\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have soft short tip catheters\n• It should retain its shape for multi-vessel coronary intervention\n• It should be kink resistant\n item38 1 pices
39 39 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. ¬¬5: SPECIAL LARGE LUMEN PTCA GUIDING CATHETERS OF 6 FRENCH SIZE WITH SIDE HOLES\n• Must have 6Fr. guiding catheters with I.D of 0.071 inch or more\n• Failure to comply with the specifications will lead to rejection as a whole from this item.\n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and others.\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have soft short tip catheters\n• It should retain its shape for multi-vessel coronary intervention\n• It should be kink resistant\n item39 1 pices
40 40 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. ¬¬6: SPECIAL LARGE LUMEN PTCA GUIDING CATHETERS OF 7 FRENCH SIZE \n• Must have 7Fr. guiding catheters with I.D of 0.081 inch or more\n• Failure to comply with the specifications will lead to rejection as a whole from this item.\n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and others.\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have soft short tip catheters\n• It should retain its shape for multi-vessel coronary intervention\n• It should be kink resistant\n item40 1 pices
41 41 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. ¬¬7: SPECIAL LARGE LUMEN PTCA GUIDING CATHETERS OF 7 FRENCH SIZE WITH SIDE HOLES\n• Must have 7Fr. guiding catheters with I.D of 0.081 inch or more\n• Failure to comply with the specifications will lead to rejection as a whole from this item.\n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and others.\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have soft short tip catheter\n• It should retain its shape for multi-vessel coronary intervention\n• It should be kink resistant\n item41 1 pices
42 42 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. ¬¬8: SPECIAL LARGE LUMEN PTCA GUIDING CATHETERS OF 8 FRENCH SIZE \n• Must have 8Fr. guiding catheters with I.D of 0.090 inch or more\n• Failure to comply with the specifications will lead to rejection as a whole from this item.\n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and others.\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have soft short tip catheters\n• It should retain its shape for multi-vessel coronary intervention\n• It should be kink resistant\n item42 1 pices
43 43 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. ¬¬9: SPECIAL LARGE LUMEN PTCA GUIDING CATHETERS OF 8 FRENCH SIZE WITH SIDE HOLES\n• Must have 8Fr. guiding catheters with I.D of 0.090 inch or more\n• Failure to comply with the specifications will lead to rejection as a whole from this item.\n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and others.\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have soft short tip catheter\n• It should retain its shape for multi-vessel coronary intervention\n• It should be kink resistant\n item43 1 pices
44 44 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. ¬¬10: SPECIAL LARGE LUMEN PTCA GUIDING CATHETERS OF 5 FRENCH SIZE \n• Must have 5 Fr. guiding catheters with I.D of 0.058 inch or more\n• Failure to comply with the specifications will lead to rejection as a whole from this item.\n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and others.\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have soft short tip catheters\n• It should retain its shape for multi-vessel coronary intervention\n• It should be kink resistant\n item44 1 pices
45 45 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. ¬¬11: SPECIAL LARGE LUMEN PTCA GUIDING CATHETERS OF 5 FRENCH SIZE WITH SIDE HOLES\n• Must have 5 Fr. guiding catheters with I.D of 0.058 inch or more\n• Failure to comply with the specifications will lead to rejection as a whole from this item.\n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and others.\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have soft short tip catheter\n• It should retain its shape for multi-vessel coronary intervention\n• It should be kink resistant\n item45 1 pices
46 46 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 12: 4 Fr GUIDE CATHETER FOR PTCA IN VARIOUS SHAPES item46 1 pices
47 47 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 13: HYDROPHILIC COATED PTCA GUIDING CATHETER FOR DIFFICULT VASCULAR ACCESS\n• Must have 5- 8 Fr. guiding catheters \n• Must have all possible shapes including catheters: Judkins/Femoral - left and right, Extra back up support, Amplatz-left and right, Voda, Multipurpose, Hockey stick, Bypass-graft, LIMA interventions and radial curves\n• Should also have soft short tip catheters\n item47 1 pices
48 48 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 14: PTCA GUIDING CATHETER DEDICATED FOR TRANSRADIAL INTERVENTIONS\n• Sizes of 5 Fr and 6 Fr\n• Should have all possible shapes and variation for transradial interventions\n• Should also have soft atraumatic tip\n item48 1 pices
49 49 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 15: PTCA GUIDING CATHETER DEDICATED FOR TRANSRADIAL INTERVENTIONS FOR HOOKING BOTH RIGHT AND LEFT CORONARIES IN SINGLE PASS\n• Sizes of 5 Fr and 6 Fr\n• Should have all possible shapes and variation for transradial interventions\n• Should also have soft atraumatic tip\n• Must have curves appropriate for hooking both RCA and LCA with the same catheter design and curve\n item49 1 pices
50 50 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 16: PTCA GUIDING CATHETER WITH SIDE HOLES DEDICATED FOR TRANSRADIAL INTERVENTIONS\n• Sizes of 5 Fr and 6 Fr\n• Should have all possible shapes and variation for transradial interventions\n• Should also have soft atraumatic tip\n item50 1 pices
51 51 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 17: PTCA GUIDING CATHETER WITH SIDE HOLES DEDICATED FOR TRANSRADIAL INTERVENTIONS FOR HOOKING BOTH RIGHT AND LEFT CORONARIES IN SINGLE PASS\n• Sizes of 5 Fr and 6 Fr\n• Should have all possible shapes and variation for transradial interventions\n• Should also have soft atraumatic tip\n• Must have curves appropriate for hooking both RCA and LCA with the same catheter design and curve\n item51 1 pices
52 52 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 18: SPECIAL LARGE LUMEN PTCA GUIDING CATHETER DEDICATED FOR TRANSRADIAL INTERVENTIONS\n• Must have 5Fr and 6Fr guide catheters\no 5Fr should have ID of 0.058 inch or more\no 6Fr should have ID of 0.071 inch or more\n• Should have all possible shapes and variation for transradial interventions\n• Should also have soft atraumatic tip\n item52 1 pices
53 53 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 19: SPECIAL LARGE LUMEN PTCA GUIDING CATHETER DEDICATED FOR TRANSRADIAL INTERVENTIONS FOR HOOKING BOTH RIGHT AND LEFT CORONARIES IN SINGLE PASS\n• Must have 5Fr and 6Fr guide catheters\no 5Fr should have ID of 0.058 inch or more\no 6Fr should have ID of 0.071 inch or more\n• Should have all possible shapes and variation for transradial interventions\n• Should also have soft atraumatic tip\n• Must have curves appropriate for hooking both RCA and LCA with the same catheter design and curve\n item53 1 pices
54 54 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 20: SPECIAL LARGE LUMEN PTCA GUIDING CATHETER WITH SIDE HOLES DEDICATED FOR TRANSRADIAL INTERVENTIONS\n• Must have 5Fr and 6Fr guide catheters\no 5Fr should have ID of 0.058 inch or more\no 6Fr should have ID of 0.071 inch or more\n• Should have all possible shapes and variation for transradial interventions\n• Should also have soft atraumatic tip\n item54 1 pices
55 55 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 21: SPECIAL LARGE LUMEN PTCA GUIDING CATHETER WITH SIDE HOLES DEDICATED FOR TRANSRADIAL INTERVENTIONS FOR HOOKING BOTH RIGHT AND LEFT CORONARIES IN SINGLE PASS\n• Must have 5Fr and 6Fr guide catheters\no 5Fr should have ID of 0.058 inch or more\no 6Fr should have ID of 0.071 inch or more\n• Should have all possible shapes and variation for transradial interventions\n• Should also have soft atraumatic tip\n• Must have curves appropriate for hooking both RCA and LCA with the same catheter design and curve\n item55 1 pices
56 56 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 22: SPECIAL SHEATHLESS PTCA GUIDING CATHETER DEDICATED FOR TRANSRADIAL INTERVENTIONS\n• Sizes of 5 Fr, 6 Fr and 7 Fr\n• Should have all possible shapes and variation for transradial interventions\n• Should also have availability of smaller length catheters (90 cm or less) \n• Should also have availability of catheters with side holes\n• Should also have soft short tip catheters\n item56 1 pices
57 57 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 23: PTCA GUIDE EXTENSION CATHETER FOR RAPID EXCHANGE COMPATIBLE AND ENHANCING THE SUPPORT OF 6 Fr and 7 Fr GUIDE CATHETER\n• Compatible with 6 Fr and 7 Fr guide catheter\n• Rapid exchange length of 25 cm with 150 cm working length\n• Guide extension segment of 25 cm\n item57 1 pices
58 58 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 24: PTCA GUIDE EXTENSION CATHETER FOR RAPID EXCHANGE COMPATIBLE AND ENHANCING THE SUPPORT OF 5 Fr AND 5.5 Fr GUIDE CATHETER\n• Compatible with 5 Fr and 5.5 Fr guide catheter\n• Rapid exchange length of 25 cm with 150 cm working length\n• Guide extension segment of 25 cm\n item58 1 pices
59 59 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 25: PTCA GUIDE EXTENSION CATHETER FOR RAPID EXCHANGE COMPATIBLE AND ENHANCING THE SUPPORT OF 8 Fr GUIDE CATHETER\n• Compatible with 8 Fr guide catheter\n• Rapid exchange length of 25 cm with 150 cm working length\n• Guide extension segment of 25 cm\n item59 1 pices
60 60 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 26: SPECIAL LARGE LUMEN PTCA GUIDE EXTENSION CATHETER FOR RAPID EXCHANGE COMPATIBLE AND ENHANCING THE SUPPORT OF 6 Fr and 7 Fr GUIDE CATHETER\n• Compatible with 6 Fr and 7 Fr guide catheter\n• Must have ID as follows:\no 6 Fr: 0.057 inch or more\no 7 Fr: 0.063 inch or more\n• Rapid exchange length of 25 cm with 150 cm working length\n• Guide extension segment of 25 cm\n item60 1 pices
61 61 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 27: SPECIAL LARGE LUMEN PTCA GUIDE EXTENSION CATHETER FOR RAPID EXCHANGE COMPATIBLE AND ENHANCING THE SUPPORT OF 8 Fr GUIDE CATHETER\n• Compatible with 8 Fr guide catheter\n• Must have ID as follows:\no 8 Fr: 0.072 inch or more\n• Rapid exchange length of 25 cm with 150 cm working length\n• Guide extension segment of 25 cm\n item61 1 pices
62 62 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 28: OVER THE WIRE PTCA GUIDE EXTENSION CATHETER OVER THE WIRE COMPATIBLE WITH 6F, 7F AND 8F FOR ENHANCING THEIR SUPPORT\n item62 1 pices
63 63 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 29: PTCA GUIDE EXTENSION CATHETER WITH THE OPTION OF TRAPPING BALLOON – GUIDE EXTENSION CATHETER WITH INBUILT TRAPPING BALLOON TO MAINTAIN GUIDEWIRE POSITION\n item63 1 pices
64 64 GROUP B3 GUIDING CATHETERS FOR PTCA\nItem No. 30: TRAPPING BALLOON CATHETER\n• Should have auto stop mechanism\n• Should have small shaft profile and easily pushable shaft\n• Should be designed to trap a coronary guidewire at low inflation pressure\n item64 1 pices
65 65 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 1: PTCA GUIDE WIRE HAVING REGULAR SHAFT SUPPORT WITH FLOPPY TIP\n• Should be available in both routine and exchange lengths\n item65 1 pices
66 66 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 2: PTCA GUIDE WIRE WITH EXTRA-SUPPORT SHAFT AND FLOPPY TIP\n• Should be available in both routine and exchange lengths\n item66 1 pices
67 67 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 3: POLYMER COVERED PTCA GUIDE WIRE WITH DISTAL SPRING COIL\n• Should have hydrophilic polymer cover\n item67 1 pices
68 68 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 4: POLYMER COVERED PTCA GUIDE WIRE WITHOUT DISTAL SPRING COIL \n• Should have hydrophilic polymer cover\n item68 1 pices
69 69 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 5: PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING NON-TAPERING DISTAL TIP \n• Should be of 0.014-inch diameter, non-tapering distal tip\n• Should not have any polymer coating\n item69 1 pices
70 70 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 6: PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING DISTAL TIP\n• Should be of 0.014-inch diameter with tapering distal tip\n• Should not have any polymer coating\n item70 1 pices
71 71 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 7: PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING 0.012 INCH DISTAL TIP \n• Should be of 0.014-inch diameter, distal tip tapering to 0.012 inch\n• Should not have any polymer coating\n item71 1 pices
72 72 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 8: PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING 0.011 INCH DISTAL TIP \n• Should be of 0.014-inch diameter, distal tip tapering to 0.011 inch\n• Should not have any polymer coating\n item72 1 pices
73 73 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 9: PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING 0.010 INCH DISTAL TIP \n• Should be of 0.014-inch diameter, distal tip tapering to 0.010 inch\n• Should not have any polymer coating\n item73 1 pices
74 74 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 10: PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING 0.009 INCH DISTAL TIP \n• Should be of 0.014-inch diameter, distal tip tapering to 0.009 inch\n• Should not have any polymer coating\n item74 1 pices
75 75 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 11: PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING 0.008 INCH DISTAL TIP \n• Should be of 0.014-inch diameter, distal tip tapering to 0.008 inch\n• Should not have any polymer coating\n item75 1 pices
76 76 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 12: POLYMER COVERED PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING NON-TAPERING DISTAL TIP \n• Should be of 0.014-inch diameter, non-tapering distal tip\n item76 1 pices
77 77 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 13: POLYMER COVERED PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING DISTAL TIP\n• Should be of 0.014-inch diameter with tapering distal tip\n item77 1 pices
78 78 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 14: POLYMER COVERED PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING 0.012 INCH DISTAL TIP \n• Should be of 0.014-inch diameter, distal tip tapering to 0.012 inch\n item78 1 pices
79 79 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 15: POLYMER COVERED PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING 0.011 INCH DISTAL TIP \n• Should be of 0.014-inch diameter, distal tip tapering to 0.011 inch\n item79 1 pices
80 80 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 16: POLYMER COVERED PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING 0.010 INCH DISTAL TIP \n• Should be of 0.014-inch diameter, distal tip tapering to 0.010 inch\n• Should not have any polymer coating\n item80 1 pices
81 81 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 17: POLYMER COVERED PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING 0.009 INCH DISTAL TIP \n• Should be of 0.014-inch diameter, distal tip tapering to 0.009 inch\n item81 1 pices
82 82 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 18: POLYMER COVERED PTCA GUIDE WIRE DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TAPERING 0.008 INCH DISTAL TIP \n• Should be of 0.014-inch diameter, distal tip tapering to 0.008 inch\n item82 1 pices
83 83 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 19: PTCA GUIDE WIRES DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TIP LOAD OF 1-2 GMS\n item83 1 pices
84 84 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 20: PTCA GUIDE WIRES DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TIP LOAD OF 2-3 GMS\n item84 1 pices
85 85 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 21: PTCA GUIDE WIRES DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TIP LOAD OF 3-6 GMS\n item85 1 pices
86 86 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 22: PTCA GUIDE WIRES DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TIP LOAD OF 6-9 GMS item86 1 pices
87 87 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 23: PTCA GUIDE WIRES DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TIP LOAD 9-12 GMS item87 1 pices
88 88 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 24: PTCA GUIDE WIRES DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TIP LOAD 12-15 GMS item88 1 pices
89 89 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 25: PTCA GUIDE WIRES DEDICATED FOR CHRONIC TOTAL OCCLUSION HAVING TIP LOAD MORE THAN 15 GMS item89 1 pices
90 90 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 26: PTCA GUIDE WIRES FOR CHRONIC TOTAL OCCLUSION DEDICATED FOR RETROGRADE APPROACH item90 1 pices
91 91 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 27: PTCA GUIDE WIRES DEDICATED FOR RETROGRADE CHRONIC TOTAL OCCLUSION FOR NEGOTIATING COLLATERALS item91 1 pices
92 92 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 28: PTCA GUIDE WIRES DEDICATED FOR COMPLEX ANTRGRADE CHRONIC TOTAL OCCLUSION INTERVENTIONS item92 1 pices
93 93 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 29: PTCA GUIDE WIRES DEDICATED FOR COMPLEX CHRONIC TOTAL OCCLUSION INTERVENTIONS FOR SUB-INTIMAL TRACKING AND REENTRY item93 1 pices
94 94 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 30: PTCA GUIDE WIRE WITH FLOPPY TIP AND EXTRA-SUPPORT SHAFT STRENGTH HAVING LATERAL SUPPORT OF 20-25 GMS AT 155MM OF WIRE item94 1 pices
95 95 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 31: HEAVY DUTY PTCA GUIDE WIRE WITH FLOPPY TIP HAVING LATERAL SUPPORT OF 25 -50 GMS AT 155MM OF WIRE item95 1 pices
96 96 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 32: VERY HEAVY DUTY PTCA GUIDE WIRE WITH FLOPPY TIP HAVING LATERAL SUPPORT OF MORE THAN 50 GMS AT 155 MM OF WIRE item96 1 pices
97 97 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 33: PTCA GUIDE WIRE WITH FLOPPY TIP HAVING MULTIPLE MARKERS FOR MEASURING THE LENGTH OF STENOTIC SEGMENT item97 1 pices
98 98 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 34: PTCA GUIDE WIRE WITH EXTRA SUPPORT SHAFT AND FLOPPY TIP HAVING MULTIPLE MARKERS FOR MEASURING THE LENGTH OF STENOTIC SEGMENT item98 1 pices
99 99 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 35: PTCA GUIDE WIRE HAVING STAILESS STEEL CORE MATERIAL AND FLOPPY CORE TO TIP DESIGN \n• Should have a stainless steel core material \n• Should have a Shaping Ribbon Tip wire tip style\n• Should have a non-tapering distal tip\n• Should have an extreme floppy tip with tip load = 0.5 gm\n item99 1 pices
100 100 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 36: PTCA GUIDE WIRE WITH STAINLESS STEEL CORE HAVING EXTRA SUPPORT SHAFT FOR COMPLEX CORONARY INTERVENTIONS\n• Should have stainless steel core material\n• Should have a Core-to-Tip wire tip style\n• Should have a non-tapering distal tip\n• Should have a floppy tip with tip load = 1.0 gm\n• Should have a hydrophobic coating\n• Should provide extra-support for complex coronary interventions\n item100 1 pices
101 101 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 37: PTCA GUIDE WIRE HAVING STAINLES STEEL CORE AND TAPERING TIP DEDICATED FOR CHRONIC TOTAL OCCLUSION \n• Should have stainless steel core material\n• Should have a Core-to-Tip wire tip style\n• Should have a tapering distal tip, tip tapering to 0.010 inch\n• Should be available in variants having different tip loads\n• Should have a hydrophilic coating\n item101 1 pices
102 102 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 38: PTCA GUIDE WIRE HAVING STAINLESS STEEL CORE AND SINUSOIDAL SHAFT DESIGN \n• Should have stainless steel core material\n• Should have a Shaping Ribbon wire tip style\n• Should have a non-tapering distal tip\n• Should have an extreme floppy tip with tip load = 0.5 gm\n• Should have a hydrophilic coating\n• Should have a distal portion of the guide wire with sinusoidal design\n item102 1 pices
103 103 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 39: PTCA GUIDE WIRE HAVING ELASTINITE NITINOL CORE AND FLOPPY CORE TO TIP DESIGN \n• Should have a non-kinkable Elastinite- Nitinol core material\n• Should have a Core-to-Tip wire tip style\n• Should have a non-tapering distal tip\n• Should have a floppy tip with tip load = 0.8 gm\n• Should be available in both regular and exchange length wires\n item103 1 pices
104 104 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 40: PTCA GUIDE WIRES HAVING ELASTINITE NITINOL CORE AND FLOPPY SHAPING RIBBON TIP DESIGN \n• Should have a non-kinkable Elastinite- Nitinol core material\n• Should have a Shaping Ribbon wire tip style\n• Should have a non-tapering distal tip\n• Should have a floppy tip with tip load = 0.8 gm\n• Should be available in both regular and exchange length wires\n item104 1 pices
105 105 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 41: PTCA GUIDE WIRE WITH EXTRA SUPPORT SHAFT HAVING ELASTINITE NITINOL CORE FOR COMPLEX CORONARY INTERVENTIONS \n• Should have a non-kinkable Elastinite- Nitinol core material\n• Should have a Shaping Ribbon wire tip style\n• Should have a non-tapering distal tip\n• Should have a floppy tip with tip load = 0.8 gm\n• Should provide extra-support for complex coronary interventions\n item105 1 pices
106 106 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 42: PTCA GUIDE WIRE HAVING DURASTEEL CORE WITH FLOPPY TIP\n• Should have durasteel core material\n• Should have a Core-to-Tip wire tip style\n• Should have a non-tapering distal tip\n• Should be available in tip loads = 1.0 gm\n• Should have a hydrophilic coating\n item106 1 pices
107 107 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 43: PTCA GUIDE WIRE HAVING DURASTEEL CORE DEDICATED FOR CTO LESIONS \n• Should have durasteel core material\n• Should have a Core-to-Tip wire tip style\n• Should have a non-tapering distal tip\n• Should be available in variants having different tip loads\n• Should have a hydrophilic coating\n• Should have a polymer sleeve covering\n item107 1 pices
108 108 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 44: PTCA GUIDE WIRE WITH DURASTEEL CORE HAVING TAPERING TIP DEDICATED FOR CTO LESIONS\n• Should have durasteel core material\n• Should have a Core-to-Tip wire tip style\n• Should have a tapering distal tip, tapering to 0.009-0.0105 inches\n• Should be available in variants having different tip loads\n• Should have a hydrophilic coating\n• Should have a polymer sleeve covering\n item108 1 pices
109 109 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 45: POLYMER COVERED PTCA GUIDE WIRE HAVING DURASTEEL CORE \n• Should have Durasteel core material\n• Should have a Core-to-Tip wire tip style\n• Should have a non-tapering distal tip\n• Should have a wires with varying tip loads between 0.8-1.2 gm\n• Should have a hydrophilic coating\n• Should have a full polymer cover\n• Should be available in variants having different shaft support\n item109 1 pices
110 110 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 46: POLYMER COVERED PTCA GUIDE WIRE HAVING DURASTEEL CORE DEDICATED FOR CTO LESIONS \n• Should have Durasteel core material\n• Should have a Core-to-Tip wire tip style\n• Should have a non-tapering distal tip\n• Should have wires with varying tip loads between 1.2-5.0 gm\n• Should have a hydrophilic coating\n• Should have a full polymer cover\n item110 1 pices
111 111 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 47: PTCA GUIDE WIRE HAVING FUSED STAINLESS STEEL AND NITINOL CORES \n• Should have nitinol (distal) core and stainless steel (shaft) core \n• Wire cores fused using “Duo-Core” technology having 1:1 torque transmission\n• Should have a “M Coat” distal hydrophilic coating \n• Should be available in both routine and exchange lengths\n item111 1 pices
112 112 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 48: PTCA GUIDE WIRE HAVING WITH SUPER ELASTIC NITINOL ALLOY CORE \n FOR CHRONIC TOTAL OCCLUSION\n• Should be of 0.014-inch diameter, non-tapering distal tip\n• Should have polyurethane distal tip\n• Should have “M-coat” for hydrophilic coating\n item112 1 pices
113 113 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 49: PTCA GUIDE WIRE HAVING JOINTLESS DISTAL SPRING COIL \n• Should have one piece core wire with jointless distal spring coil\n• Should have hydrophilic slip-coat coating over the distal wire\n• Should have a non-tapering distal tip\n• Should have a tip load of 0.8 gm\n item113 1 pices
114 114 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 50: PTCA GUIDE WIRE WITH EXTRA SUPPORT SHAFT HAVING JOINTLESS DISTAL SPRING COIL \n• Should have one piece core wire with jointless distal spring coil\n• Should have a Core to Tip design\n• Should have a non-tapering distal tip\n• Should have a silicone hydrophobic coating over the spring coil\n• Should have a tip load of 0.7 gm\n• Should not have any polymeric cover\n item114 1 pices
115 115 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 51: PTCA GUIDE WIRE HAVING COMPOSITE CORE AND JOINTLESS DISTAL SPRING COIL \n• Should have one piece core wire with jointless distal spring coil\n• Should have a composite core with ACTONE inside\n• Should have a non-tapering distal tip\n• Should have hydrophilic slip-coat coating over the distal wire\n• Should have wire tip load of 0.7 gm\n item115 1 pices
116 116 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 52: PTCA GUIDE WIRE HAVING COMPOSITE CORE AND JOINTLESS DISTAL SPRING COIL \n• Should have one piece core wire with jointless distal spring coil\n• Should have a composite core with ACTONE inside\n• Should have a non-tapering distal tip\n• Should have a hybrid coating with hydrophobic silicone coating over the distal most tip and a hydrophilic slip-coat coating proximally\n• Should have tip load of 0.5 gm\n• Should have wires with extra shaft support also\n item116 1 pices
117 117 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 53: PTCA GUIDE WIRE HAVING POLYMER JACKET, COMPOSITE CORE AND JOINTLESS DISTAL SPRING COIL \n• Should have one piece core wire with jointless distal spring coil\n• Should have a composite core with ACTONE inside \n• Should have a non-tapering distal tip\n• Should have a polymer jacket\n• Should have hydrophilic slip-coat coating over the distal wire\n• Should have tip load of 0.8 gm\n item117 1 pices
118 118 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 54: PTCA GUIDE WIRE HAVING COMPOSITE CORE AND JOINTLESS DISTAL SPRING COIL AND VERY LOW TIP LOAD \n• Should have one piece core wire with jointless distal spring coil\n• Should have a composite core with ACTONE inside \n• Should have a non-tapering distal tip\n• Should have hydrophilic slip-coat coating over the distal wire\n• Should have tip load of 0.3 gm\n• Should have wires with routine and exchange length\n item118 1 pices
119 119 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 55: PTCA GUIDE WIRE HAVING POLYMER SLEEVE AND JOINTLESS DISTAL SPRING COIL \n• Should have one piece core wire with jointless distal spring coil\n• Should have a non-tapering distal tip\n• Should have a polymer sleeve\n• Should have hydrophilic slip-coat coating \n• Should have wires with tip load between 0.8-1.0 gm\n item119 1 pices
120 120 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 56: PTCA GUIDE WIRE HAVING POLYMER SLEEVE, JOINTLESS DISTAL SPRING COIL AND TAPERING TIP \n• Should have one piece core wire with jointless distal spring coil\n• Should have a core to tip design\n• Should have a tapering distal tip to 0.009 inch\n• Should have a polymer sleeve or jacket\n• Should have hydrophilic slip-coat coating \n• Should have tip load between 0.8-1.0 gm\n item120 1 pices
121 121 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 57: PTCA GUIDE WIRE HAVING POLYMER SLEEVE, JOINTLESS DISTAL SPRING COIL AND TAPERING TIP \n• Should have one piece core wire with jointless distal spring coil\n• Should have a composite core with ACTONE inside \n• Should have a tapering distal tip to 0.010 inch\n• Should have a polymer sleeve or jacket\n• Should have hydrophilic slip-coat coating \n• Should have wires with tip loads of 0.6 and 1.0 gm\n item121 1 pices
122 122 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 58: PTCA GUIDE WIRE HAVING COMPOSITE CORE AND JOINTLESS DISTAL SPRING COIL DEDICATED FOR CTO LESIONS \n• Should have one piece core wire with jointless distal spring coil\n• Should have a composite core with ACTONE inside \n• Should have a micro-cone tip profile and pre-shaped tip\n• Should have hydrophilic slip-coat coating \n• Should have varying wires with tapering distal tip of 0.010, 0.011 and 0.012 inches\n• Should have wires with tip loads of 1.7, 3.5 and 4.5 gms for wires with distal tip loads of 0.010, 0.011 and 0.012 inches, respectively\n item122 1 pices
123 123 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 59: PTCA GUIDE WIRE HAVING COMPOSITE CORE AND JOINTLESS DISTAL SPRING COIL DEDICATED FOR CHRONIC TOTAL OCCLUSION \n• Should have one piece core wire with jointless distal spring coil\n• Should have a composite core with ACTONE inside \n• Should have a micro-cone tip profile and pre-shaped tip\n• Should have hydrophilic slip-coat coating \n• Should have varying wires with tapering distal tip of 0.011 and 0.012 inches\n• Should have wires with tip loads of 2.0, 4.0 and 6.0 gms for wires with distal tip loads of 0.011, 0.012 and 0.012 inches, respectively\n item123 1 pices
124 124 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 60: PTCA GUIDE WIRE, NON-TAPERING, FOR CHRONIC TOTAL OCCLUSION WITH DISTAL SPRING COIL AND HYDROPHOBIC COATING \n• Should have one piece core wire with jointless distal spring coil\n• Should have a core to tip design\n• Should have a non-tapering distal tip\n• Should have wires available in the tip loads of 3, 4.5, 6, 9, 12 gms\n• Should have distal hydrophobic coating\n• Should not have any polymeric covering\n• The distal radio-opaque portion of wire should be 11 cm \n item124 1 pices
125 125 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 61: SPECIAL PTCA GUIDE WIRE, NON-TAPERING FOR CHRONIC TOTAL OCCLUSION WITH DISTAL SPRING COIL AND HYROPHILIC COATING \n• Should have one piece core wire with jointless distal spring coil\n• Should have a core to tip design\n• Should have a non-tapering distal tip\n• Should have wires available in the tip load of 3 gms\n• Should have hydrophilic slip-coat coating\n• Should not have any polymeric covering\n• The distal radio-opaque portion of wire should be 11 cm \n item125 1 pices
126 126 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 62: PTCA GUIDE WIRE, TAPERING TO 0.009 INCH DISTALLY DEDICATED FOR CHRONIC TOTAL OCCLUSION \n• Should have one piece core wire with jointless distal spring coil\n• Should have a core to tip design\n• Should have a distal tip tapering to 0.009 inch\n• Should be available in distal tip load of 9 and 12 gms\n• The distal radio-opaque portion of wire should be 20 cm\n• Should have variants with wires having either hydrophilic slip-coat coating or hydrophobic silicone coating\n• Should not have any polymeric covering\n item126 1 pices
127 127 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 63: PTCA GUIDE WIRE, TAPERING TO 0.008 INCH DISTALLY DEDICATED FOR CHRONIC TOTAL OCCLUSION\n• Should have one piece core wire with jointless distal spring coil\n• Should have a core to tip design\n• Should have a distal tip tapering to 0.008 inch\n• Should be available in distal tip load of 20 gms\n• The distal radio-opaque portion of wire should be 17 cm\n• Should have hydrophilic slip-coat coating\n• Should not have any polymeric covering\n item127 1 pices
128 128 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 64: SPECIAL 0.010 INCH PTCA GUIDE WIRE DEDICATED FOR EXTERNALIZATION DURING RETROGRADE CTO \n• Should have a core to tip design\n• Should have a wire length of 330 cm\n• Should have a wire outer diameter of 0.010 inch\n• Should be available in distal tip load of 3.0 gm\n• Should have distal hydrophilic and proximal hydrophobic coating\n• Should not have any polymeric covering\n item128 1 pices
129 129 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 65: PTCA GUIDE WIRE HAVING DOUBLE CORE DESIGN HAVING STAINLESS STEEL AND NITINOL \n• Should have a double core design with proximal Stainless Steel and distal Nitinol\n• Should have a Shaping Ribbon wire tip style\n• Should have a double coil wire tip\n• Should be available in standard and exchange lengths\n• Should be available in variants having Hydro-track or Propel coating\n• Should have variants with different shaft support\n item129 1 pices
130 130 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 66: PTCA GUIDE WIRE HAVING STAINLESS STEEL CORE HAVING COAXIAL DESIGN \n• Should have a co-axial, stainless steel core having ACCU-CORE Technology\n• Should have a round Core-to-tip style\n• Should be available in variants having Hydro-track or Propel coating\n• Should be available in standard and exchange lengths\n item130 1 pices
131 131 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 67: PTCA GUIDE WIRE HAVING STAINLESS STEEL CORE AND COAXIAL DESIGN DEDICATED FOR CHRONIC TOTAL OCCLUSION \n• Should have a co-axial, stainless steel core having ACCU-CORE Technology\n• Should have a round Core-to-tip style\n• Should be available in variants having Hydro-track or Propel coating\n• Should be available in variants having different tip loads of 3, 6, 9, 12 and 15 gms\n• Should be available in non-tapering for tip load 3, 6 gms variants; and tapering distal tip to 0.009 inches for tip loads of 9, 12, 15 gms variants\n item131 1 pices
132 132 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 68: PTCA GUIDE WIRE WITH TIP MADE UP OF MULTIPLE STIFF AND FLEXIBLE COMPONENTS \n• Tip should have Slip-Coat hydrophilic coating\n item132 1 pices
133 133 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 69: PTCA GUIDE WIRE, NON-TAPERING, FOR CHRONIC TOTAL OCCLUSION WITH SUPER ELASTIC NITINOL ALLOY CORE \n• Should be of 0.014-inch diameter, non-tapering distal tip\n• Should have polyurethane distal tip\n• Should have “M-coat” for hydrophilic coating\n item133 1 pices
134 134 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 70: TAPERING PTCA GUIDE WIRE, TAPERING, 0.010 INCH DISTAL TIP DEDICATED FOR CHRONIC TOTAL OCCLUSION \n• Should be of 0.014-inch diameter\n• Should have a tapering distal tip to 0.010 inch\n• Should have a hydro coat hydrophilic coating\n• Should be available in variable distal tip load\n item134 1 pices
135 135 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 71: PTCA GUIDE WIRE HAVING COAXIAL SPRING DESIGN DEDICATED FOR CHRONIC TOTAL OCCLUSION\n• Should be available in variable distal tip loads \n• Should be available in tip loads : 3, 6, 9, 12 and 15 gms\n• Should have either hydrophilic or silicone coating\n• Should have co-axial spring design\n• The distal radio-opaque portion of wire should be less than 10 cm\n item135 1 pices
136 136 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 72: PTCA GUIDE WIRE WITH BIDIRECTIONAL DEFLECTABLE DISTAL TIP item136 1 pices
137 137 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 73: EXTENSION (DOC) WIRE FOR APPROVED REGULAR LENGTH PTCA GUIDE WIRES AS QUOTED IN THIS TENDER item137 1 pices
138 138 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 74: PTCA GUIDE WIRE SECURING DEVICE\n• Should have tapering slits to secure the guide wires for single operator procedure\n• Should allow controlled micro-movement of catheters and wires\n• Device should have features to secure firmly in the operative field\n item138 1 pices
139 139 GROUP B4 PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY- PTCA GUIDEWIRES\nItem No. 75: PTCA GUIDE WIRE DOCKING DEVICE\n• Should allow easy introduction of PTCA guide wire into catheters and atherectomy burrs \n• Docking device should have features to secure firmly in the operative field\n• Should have slits to hold the guide wire for single operator procedure\n item139 1 pices
140 140 GROUP B5 SPECIAL DEVICES FOR CHRONIC TOTAL OCCLUSION ANGIOPLASTY\nItem No. 1: PTCA CATHETER WITH DEFLECTABLE DISTAL END TO GUIDE THE DIRECTION OF PTCA GUIDE WIRE item140 1 pices
141 141 GROUP B5 SPECIAL DEVICES FOR CHRONIC TOTAL OCCLUSION ANGIOPLASTY\nItem No. 2: MICRO-CHANNEL DILATOR CATHETER WITH TAPERED SOFT TIP AND HYDROPHILIC SHAFT\n• Should have shaft with OD of 2.6 Fr or lower\n• Should be available in 130 to 150 cm for antegrade and retrograde approach\n item141 1 pices
142 142 GROUP B5 SPECIAL DEVICES FOR CHRONIC TOTAL OCCLUSION ANGIOPLASTY\nItem No. 3: CORONARY MICROCATHETER WITH TAPERED TIP FOR CTO INTERVENTION\n• Must have a distal tip OD of 1.8 Fr or lower\n• Should be available in 130 to 150 cm in length for both antegrade and retrograde approach\n item142 1 pices
143 143 GROUP B5 SPECIAL DEVICES FOR CHRONIC TOTAL OCCLUSION ANGIOPLASTY\nItem No. 4: SPECIAL MICROCATHETER FOR EMBOLISATION ALLOWING A COAXIAL GUIDEWIRE OF 0.021” DIAMETER\n item143 1 pices
144 144 GROUP B5 SPECIAL DEVICES FOR CHRONIC TOTAL OCCLUSION ANGIOPLASTY\nItem No. 5: SPECIAL CORONARY MICROCATHETER FOR CTO HAVING WIRE BRAIDING FOR TRANSMISSION OF ROTATIONAL MOVEMENTS FOR CTO PENETRATION\n item144 1 pices
145 145 GROUP B5 SPECIAL DEVICES FOR CHRONIC TOTAL OCCLUSION ANGIOPLASTY\nItem No. 6: SPECIAL CORONARY MICROCATHETER FOR CTO HAVING DUAL WIRE BRAIDING FOR EFFICIENT TRANSMISSION OF ROTATIONAL MOVEMENTS FOR CTO PENETRATION\n item145 1 pices
146 146 GROUP B5 SPECIAL DEVICES FOR CHRONIC TOTAL OCCLUSION ANGIOPLASTY\nItem No. 7: DUAL LUMEN MICROCATHETER FOR SIDE BRANCH ACCESS item146 1 pices
147 147 GROUP B5 SPECIAL DEVICES FOR CHRONIC TOTAL OCCLUSION ANGIOPLASTY\nItem No. 8: SPECIAL MICROCATHETER WITH VERY LOW ENTRY AND CROSSING PROFILE\n• Must have a distal tip entry profile of 1.4 Fr or lower and crossing profile of 2.1 Fr or lower\n• Must be available in 130 to 150 cm length for both antegrade and retrograde approach\n item147 1 pices
148 148 GROUP B5 SPECIAL DEVICES FOR CHRONIC TOTAL OCCLUSION ANGIOPLASTY\nItem No. 9: SPECIAL ANGLED TIP CORONARY MICROCATHETER FOR CTO\n• Must be available in various angles (45o, 90o and 120o)\n• Should be available in 130 to 150 cm length for both antegrade and retrograde approach\n• Distal OD should be 2.4 Fr or lower\n item148 1 pices
149 149 GROUP B5 SPECIAL DEVICES FOR CHRONIC TOTAL OCCLUSION ANGIOPLASTY\nItem No. 10: SPECIAL CROSSING CATHETER FOR CTO FOR BLUNT SUB-INTIMAL DISSECTION item149 1 pices
150 150 GROUP B5 SPECIAL DEVICES FOR CHRONIC TOTAL OCCLUSION ANGIOPLASTY\nItem No. 11: SPECIAL LUMINAL RE-ENTRY SYSTEM FOR CTO WITH SPECIAL SELF RE-ALIGNING BALLOON WITH 2 EXIT PORTS item150 1 pices
151 151 GROUP B6 PTCA BALLOONS\nItem No. 1: PTCA BALLOON (SEMI-COMPLIANT) – MANUFACTURED IN INDIA\n• Monorail (rapid exchange) balloons\n• Should be available in all sizes and lengths\n \n item151 1 pices
152 152 GROUP B6 PTCA BALLOONS\nItem No. 2: PTCA BALLOON (SEMI-COMPLIANT) - CE MARKED \n• Monorail (rapid exchange) balloons\n• Should be available in all sizes and lengths \n \n item152 1 pices
153 153 GROUP B6 PTCA BALLOONS\nItem No. 3: PTCA BALLOON (SEMI-COMPLIANT) - US FDA APPROVED\n• Monorail (rapid exchange) balloons\n• Should be available in all sizes and lengths \n \n item153 1 pices
154 154 GROUP B6 PTCA BALLOONS\nItem No. 4: PTCA BALLOON (SEMI-COMPLIANT) – MANUFACTURED IN INDIA\n• Over-the-wire (OTW) balloons\n• Should be available in all sizes and lengths \n \n item154 1 pices
155 155 GROUP B6 PTCA BALLOONS\nItem No. 5: PTCA BALLOON (SEMI-COMPLIANT) - CE MARKED \n• Over-the-wire (OTW) balloons\n• Should be available in all sizes and lengths \n \n item155 1 pices
156 156 GROUP B6 PTCA BALLOONS\nItem No. 6: PTCA BALLOON (SEMI-COMPLIANT) - US FDA APPROVED\n• Over-the-wire (OTW) balloons\n• Should be available in all sizes and lengths \n \n item156 1 pices
157 157 GROUP B6 PTCA BALLOONS\nItem No. 7: PTCA BALLOON (NON-COMPLIANT) - MANUFACTURED IN INDIA\n• Should be available in all sizes, variable lengths\n• Should have a very high rated burst pressure \n\n item157 1 pices
158 158 GROUP B6 PTCA BALLOONS\nItem No. 8: PTCA BALLOON (NON-COMPLIANT) - CE MARKED\n• Should be available in all sizes, variable lengths\n• Should have a very high rated burst pressure \n\n item158 1 pices
159 159 GROUP B6 PTCA BALLOONS\nItem No. 9: PTCA BALLOON (NON-COMPLIANT) - US FDA APPROVED\n• Should be available in all sizes, variable lengths\n• Should have a very high rated burst pressure \n\n item159 1 pices
160 160 GROUP B6 PTCA BALLOONS\nItem No. 10: PTCA BALLOON CATHETER FOR COMPLEX CORONARY INTERVENTIONS – MANUFACTURED IN INDIA\n• Should be available in both semi-compliant and non-compliant platforms\n• Should have very low crossing profile so as to facilitate complex PTCA procedure\n\n item160 1 pices
161 161 GROUP B6 PTCA BALLOONS\nItem No. 11: PTCA BALLOON CATHETER FOR COMPLEX CORONARY INTERVENTIONS – CE MARKED \n• Should be available in both semi-compliant and non-compliant platforms\n• Should have very low crossing profile so as to facilitate complex PTCA procedure\n\n item161 1 pices
162 162 GROUP B6 PTCA BALLOONS\nItem No. 12: PTCA BALLOON CATHETER FOR COMPLEX CORONARY INTERVENTIONS – US FDA APPROVED\n• Should be available in both semi-compliant and non-compliant platforms\n• Should have very low crossing profile so as to facilitate complex PTCA procedure\n\n item162 1 pices
163 163 GROUP B6 PTCA BALLOONS\nItem No. 13: SPECIAL PTCA BALLOON (NON-COMPLIANT) \n• Should have very high rated burst pressure (more than 30 mmHg)\n• Should be available in all sizes, variable lengths\n item163 1 pices
164 164 GROUP B6 PTCA BALLOONS\nItem No. 14: SPECIAL PTCA BALLOON (NON-COMPLIANT) \n• Should have very high rated burst pressure (more than 40 mmHg)\n• Should be available in all sizes, variable lengths\n \n item164 1 pices
165 165 GROUP B6 PTCA BALLOONS\nItem No. 15: SPECIAL PTCA BALLOON (STEADY COMPLIANT) \n• Semi-compliant at low pressure and non-compliant at high pressure\n\n item165 1 pices
166 166 GROUP B6 PTCA BALLOONS\nItem No. 16: SPECIAL PTCA BALLOON CATHETER WITH VERY LOW CROSSING PROFILE \n• Must have crossing balloon profile of = 0.021 inches\n \n item166 1 pices
167 167 GROUP B6 PTCA BALLOONS\nItem No. 17: SPECIAL PTCA BALLOON FOR RETROGRADE APPROACH OF CTO\n• Should be available in regular lengths for retrograde approach\n• Should be available as over the wire (OTW)\n• Available in all sizes and lengths \n item167 1 pices
168 168 GROUP B6 PTCA BALLOONS\nItem No. 18: SPECIAL PTCA BALLOON WITH BIFLEX TIP FOR COMPLEX PROCEDURES \n item168 1 pices
169 169 GROUP B6 PTCA BALLOONS\nItem No. 19: SPECIAL NON-COMPLIANT PTCA BALLOON FOR COMPLEX CORONARY INTERVENTION \n• Must have specially designed triple layer of PTCA balloon for sustaining high pressures\n• Must have a lesion entry profile of = 0.43 mm\n• The balloon must have a hydrophilic coating\n• The balloon must be available in all the sizes 2.0, 2.25, 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4.0, 4.5 and 5.0 mm\n• The balloon must be available in 6, 8, 12 and 15 mm lengths for all the sizes between 1-5 mm\n• The balloon diameter between 2.0-4.0 mm must also be available in 20 mm length\n• The balloons with diameters of 2.5, 3.0 and 3.5 mm must also be available in long lengths of 25 and 30 mm.\n \n item169 1 pices
170 170 GROUP B6 PTCA BALLOONS\nItem No. 20: SPECIAL PTCA BALLOON FOR RETROGRADE APPROACH OF CTO\n• Should be available in long lengths for retrograde approach\n• Should be available as over the wire (OTW)\n• Available in all sizes and lengths \n \n item170 1 pices
171 171 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 1: SPECIAL LARGE PTCA BALLOONS OF 4 MM TO 4.5 MM \n• Must be available in both 4 and 4.5 mm diameters and should be available in variable balloon lengths\n item171 1 pices
172 172 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 2: SPECIAL LARGE PTCA BALLOONS OF 5 MM TO 5.5 MM \n• Must be available in both 5 and 5.5 mm diameters and should be available in variable balloon lengths\n item172 1 pices
173 173 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 3: SPECIAL PTCA BALLOON CATHETER OF 1.20 - 1.25 MM \n• Should be available in variable balloon lengths\n item173 1 pices
174 174 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 4: SPECIAL PTCA BALLOON CATHETER OF 1.10 MM \n• Should be available in variable balloon lengths\n item174 1 pices
175 175 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 5: SPECIAL PTCA BALLOON CATHETER OF 1.00 MM \n• Should be available in variable balloon lengths\n item175 1 pices
176 176 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 6: SPECIAL PTCA BALLOON CATHETER OF LESS THAN 1.00 MM \n• Should be available in variable balloon lengths\n item176 1 pices
177 177 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 7: SPECIAL NON-COMPLIANT PTCA BALLOON CATHETER OF LESS THAN 1.00 MM \n• Should be available in variable balloon lengths\n item177 1 pices
178 178 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 8: SPECIAL ZERO LENGTH PTCA BALLOON CATHETER FOR FOCAL DILATATION \n• Should be available in variable balloon diameters\n item178 1 pices
179 179 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 9: OVER THE WIRE (OTW) COAXIAL PTCA BALLOON (SEMI-COMPLIANT) \n• Should be available in all sizes and lengths\n item179 1 pices
180 180 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 10: SPECIAL OVER THE WIRE (OTW) PTCA BALLOON DEDICATED FOR ALCOHOL SEPTAL ABLATION FOR HYPERTROPHIC OBSTRUCTIVE CARDIOMYOPATHY (HOCM) item180 1 pices
181 181 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 11: SPECIAL PTCA BALLOON FOR CROSSING CTO\n• Should be available in = 1.25 mm diameter\n• Should be ultrashort with balloon length = 6 mm\n• Should have low crossing profile with no balloon fold at distal end\n item181 1 pices
182 182 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 12: SPECIAL PTCA BALLOON FOR CHRONIC TOTAL OCCLUSION (CTO) INTERVENTIONS\n• Must be available in sizes between 1 and 4 mm diameter\n• The balloon must have all the sizes of 1, 1.25, 1.5, 2.0, 2.25, 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4.0 mm\n• Must have a low entry profile of = 0.016 inch (0.41 mm) for 1.0-1.5 mm balloons\n• The balloon must have a durable hydrophilic coating \n• The balloon must have a low crossing profile of 0.58 mm for balloons 1-4 mm.\n• The balloon must be available in sizes 10, 15, 20 mm for balloon diameters of 1.25-4.0 mm\n• The 1.0 mm balloon must be available in 5 mm length\n• The balloons of diameters 2.0, 2.5, 3.0, 3.5 must also have long lengths of 30 mmm and 40 mm\n• The balloon must have a stainless steel tapered core wire design \n item182 1 pices
183 183 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 13: DEDICATED PTCA BIFURCATION BALLOON\n• Should have double rapid exchange design\n• Single simultaneous inflation for both main vessel and side branch\n• Should be compatible with 6 Fr. Guiding catheter\n item183 1 pices
184 184 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 14: DRUG ELUTING BALLOON FOR PTCA ELUTING PACLITAXEL item184 1 pices
185 185 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 15: DRUG ELUTING BALLOON FOR PTCA ELUTING ANY DRUG OTHER THAN PACLITAXEL item185 1 pices
186 186 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 16: DUAL ACCESS CATHETER FOR PTCA\n• Should have lumen for rapid exchange as well as over the wire (OTW) in same device\n• Should allow passage of additional wire, contrast or drugs from the OTW lumen while retaining the rapid exchange lumen in place\n item186 1 pices
187 187 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 17: CORONARY INFUSION/ DRUG DELIVERY CATHETER\n item187 1 pices
188 188 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 18: SCORING BALLOON CATHETER FOR PTCA \n item188 1 pices
189 189 GROUP B7 SPECIAL PTCA BALLOONS\nItem No. 19: SCORING BALLOON CATHETER FOR PTCA WITH A LOW CROSSING PROFILE OF 0.032 INCH OR LESS\n item189 1 pices
190 190 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 1: ROTATIONAL ATHERECTOMY SYSTEM WITH PRE-CONNECTED ROTABLATION BURR ATTACHED TO ROTABLATION ADVANCER – COMPATIBLE WITH THE MACHINE AVAILABLE IN CATH LAB AT AIIMS, NEW DELHI \n item190 1 pices
191 191 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 2: ROTATIONAL ATHERECTOMY BURR - COMPATIBLE WITH THE MACHINE AVAILABLE IN CATH LAB AT AIIMS, NEW DELHI \n• Should be available in all the standard sizes \n\n item191 1 pices
192 192 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 3: ROTATIONAL ATHERECTOMY ADVANCER - COMPATIBLE WITH THE MACHINE AVAILABLE IN CATH LAB AT AIIMS, NEW DELHI \n item192 1 pices
193 193 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 4: ROTATIONAL ATHERECTOMY GUIDEWIRE - COMPATIBLE WITH THE ROTATIONAL ATHERECTOMY SYSTEM AVAILABLE IN CATH LAB AT AIIMS, NEW DELHI \n item193 1 pices
194 194 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 5: ROTAGLIDE LUBRICANT FOR ROTATIONAL ATHERECTOMY\n item194 1 pices
195 195 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 6: SPECIAL ATHERECTOMY DEVICE FOR CALCIFIC CORONARY LESIONS PERFORMING BIDIRECTIONAL SANDING OF CALCIUM\n item195 1 pices
196 196 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 7: EXCIMER LASER CORONARY ATHERECTOMY CATHETER FOR COMPLEX CORONARY INTERVENTIONS – COMPATIBLE WITH MACHINE AVAILABLE AT AIIMS CATH LAB\n• Should be available in all the standard sizes (diameters)\n• Should be available in both concentric and eccentric array fibres\n\n item196 1 pices
197 197 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 8: CUTTING BALLOON FOR PTCA HAVING MICROSURGICAL ATHEROTOMES (BLADES)\n• Should be available in standard balloon diameters and lengths\n\n item197 1 pices
198 198 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 9: CUTTING BALLOON FOR PTCA- MANUFACTURED IN INDIA\n• Should be available in standard balloon diameters and lengths\n \n item198 1 pices
199 199 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 10: CUTTING BALLOON FOR PTCA-CE MARKED\n• Should be available in standard balloon diameters and lengths \n \n item199 1 pices
200 200 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 11: CUTTING BALLOON FOR PTCA-US FDA APPROVED\n• Should be available in standard balloon diameters and lengths\n \n item200 1 pices
201 201 GROUP B8 CUTTING BALLOON, ROTABALATION DEVICE AND ACCESSORIES\nItem No. 12: SHOCKWAVE INTRAVASCULAR LITHOTRIPSY CATHETER\n• Should be available in standard balloon diameters and lengths\n \n item201 1 pices
202 202 GROUP B9 MICROCATHETER, FFR WIRE AND IVUS CATHETER : \nItem No. 1: CORONARY MICROCATHETER – MANUFACTURED IN INDIA item202 1 pices
203 203 GROUP B9 MICROCATHETER, FFR WIRE AND IVUS CATHETER : \nItem No. 2: CORONARY MICROCATHETER – CE MARKED item203 1 pices
204 204 GROUP B9 MICROCATHETER, FFR WIRE AND IVUS CATHETER : \nItem No. 3: CORONARY MICROCATHETER – US FDA APPROVED item204 1 pices
205 205 GROUP B9 MICROCATHETER, FFR WIRE AND IVUS CATHETER : \nItem No. 4: INTRACORONARY PRESSSURE WIRE (FFR) FOR PTCA - COMPATIBLE WITH THE SYSTEM AVAILABLE IN AIIMS CATH LAB item205 1 pices
206 206 GROUP B9 MICROCATHETER, FFR WIRE AND IVUS CATHETER : \nItem No. 5: INTRACORONARY PRESSURE WIRE (FFR) FOR PTCA WITH WIRELESS CONNECTIVITY – COMPATIBLE WITH THE SYSTEM AVAILABLE AT AIIMS CATH LAB item206 1 pices
207 207 GROUP B9 MICROCATHETER, FFR WIRE AND IVUS CATHETER : \nItem No. 6: INTRACORONARY PRESSSURE WIRE (IFR) FOR PTCA - COMPATIBLE WITH THE SYSTEM AVAILABLE IN AIIMS CATH LAB item207 1 pices
208 208 GROUP B9 MICROCATHETER, FFR WIRE AND IVUS CATHETER : \nItem No. 7: INTRACORONARY PRESSSURE WIRE (RFR) FOR PTCA - COMPATIBLE WITH THE SYSTEM AVAILABLE IN AIIMS CATH LAB item208 1 pices
209 209 GROUP B9 MICROCATHETER, FFR WIRE AND IVUS CATHETER : \nItem No. 8: IVUS CATHETER WITH PHASED ARRAY TRANSDUCER FOR CORONARY INTERVENTIONS - COMPATIBLE WITH THE MACHINE AVAILABLE IN AIIMS CATH LAB item209 1 pices
210 210 GROUP B9 MICROCATHETER, FFR WIRE AND IVUS CATHETER : \nItem No. 9: HIGH RESOLUTION IVUS CATHETER WITH OPERATING FREQUENCY 40 MHz WITH MECHANICAL TRANSDUCER FOR CORONARY INTERVENTION – COMPATIBLE WITH MACHINE AVAILABLE AT AIIMS CATH LAB item210 1 pices
211 211 GROUP B9 MICROCATHETER, FFR WIRE AND IVUS CATHETER : \nItem No. 10: HIGH RESOLUTION IVUS CATHETER WITH OPERATING FREQUENCY 60 MHz WITH MECHANICAL TRANSDUCER FOR CORONARY INTERVENTION – COMPATIBLE WITH MACHINE AVAILABLE AT AIIMS CATH LAB item211 1 pices
212 212 GROUP B9 MICROCATHETER, FFR WIRE AND IVUS CATHETER : \nItem No. 11: OCT CATHETER FOR CORONARY INTERVENTIONS - COMPATIBLE WITH THE MACHINE AVAILABLE IN AIIMS, NEW DELHI CATH LAB item212 1 pices
213 213 GROUP B10 EMBOLIC PROTECTION AND THROMBOSUCTUION DEVICES\nItem No. 1: EMBOLIC PROTECTION DEVICE (EPD) FOR PTCA: FILTER TECHNOLOGY- MANUFACTURED IN INDIA item213 1 pices
214 214 GROUP B10 EMBOLIC PROTECTION AND THROMBOSUCTUION DEVICES\nItem No. 2: EMBOLIC PROTECTION DEVICE (EPD) FOR PTCA: FILTER TECHNOLOGY- CE MARKED\n item214 1 pices
215 215 GROUP B10 EMBOLIC PROTECTION AND THROMBOSUCTUION DEVICES\nItem No. 3: EMBOLIC PROTECTION DEVICE (EPD) FOR PTCA: FILTER TECHNOLOGY- US FDA APPROVED\n item215 1 pices
216 216 GROUP B10 EMBOLIC PROTECTION AND THROMBOSUCTUION DEVICES\nItem No. 4: MANUAL THROMBUS ASPIRATION CATHETER FOR PTCA – MANUFACTURED IN INDIA\n item216 1 pices
217 217 GROUP B10 EMBOLIC PROTECTION AND THROMBOSUCTUION DEVICES\nItem No. 5: MANUAL THROMBUS ASPIRATION CATHETER FOR PTCA - CE MARKED\n item217 1 pices
218 218 GROUP B10 EMBOLIC PROTECTION AND THROMBOSUCTUION DEVICES\nItem No. 6: MANUAL THROMBUS ASPIRATION CATHETER FOR PTCA- US FDA APPROVED\n item218 1 pices
219 219 GROUP B10 EMBOLIC PROTECTION AND THROMBOSUCTUION DEVICES\nItem No. 7: SPECIAL LARGE LUMEN THROMBUS ASPIRATION CATHETER\n• Must have a ID of 0.043” or higher at the distal tip\n• Must be compatible with 6 Fr and 7 Fr guide catheter\n• Should have forward facing tip for more efficient thrombosuction\n• Should provide an aspiration rate of at least 52 cc/min\n• Should be provided with a kit of at least 2 aspiration syringes, extension tubing with stop cock and filter baskets\n\n item219 1 pices
220 220 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 1: IABP CATHETER- MANUFACTURED IN INDIA, COMPATIBLE WITH THE AVAILABLE MACHINE IN CATH LAB item220 1 pices
221 221 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 2: IABP CATHETER - CE MARKED, COMPATIBLE WITH THE AVAILABLE MACHINE IN CATH LAB item221 1 pices
222 222 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 3: IABP CATHETER- US FDA APPROVED, COMPATIBLE WITH THE AVAILABLE MACHINE IN CATH LAB item222 1 pices
223 223 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 4: SPECIAL IABP CATHETER HAVING FIBEROPTIC TECHNOLOGY, COMPATIBLE WITH THE AVAILABLE MACHINE IN CATH LAB item223 1 pices
224 224 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 5: ACT TUBES \n• Disposable ACT tubes compatible with existing machines at AIIMS\n• Should meet highest medical industrial standards \n• Quality certification should be provided from authorized agencies\n item224 1 pices
225 225 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 6: ARTERIAL (FEMORAL) PUNCURE CLOSURE DEVICE - INTRAVASCULAR BIOABSORBABLE POLYMER BASED DEVICE item225 1 pices
226 226 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 7: ARTERIAL (FEMORAL) PUNCURE CLOSURE DEVICE - EXTRAVASCULAR CLIP BASED DEVICE item226 1 pices
227 227 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 8: ARTERIAL (FEMORAL) PUNCURE CLOSURE DEVICE - EXTRAVASCULAR SEALANT BASED DEVICE item227 1 pices
228 228 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 9: ARTERIAL (FEMORAL) PUNCURE CLOSURE DEVICE - SUTURE BASED DEVICE item228 1 pices
229 229 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 10: SPECIAL LARGE BORE VASCULAR ACCESS (UP TO 10 FRENCH AT LEAST) CLOSURE DEVICE – SUTURE BASED DEVICE item229 1 pices
230 230 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 11: SPECIAL LARGE BORE VASCULAR ACCESS (10-22 FRENCH) CLOSURE DEVICE – COLLAGEN BASED DEVICE item230 1 pices
231 231 GROUP B11 IABP CATHETERS AND FEMORAL PUNCTURE CLOSURE DEVICES\nItem No. 12: SPECIAL LARGE BORE VASCULAR ACCESS (10-20 FRENCH ) CLOSURE DEVICE – PATCH BASED OR MEMBRANE BASED item231 1 pices
232 232 GROUP B12 HEMOSTASIS DEVICES\nItem No. 1: ARTERIAL PUNCURE SEALING DEVICE USING EXTRAVASCULAR SEALENT OR COAGULANT FOR USE FOLLOWING TRANSFEMORAL INTERVENTION item232 1 pices
233 233 GROUP B12 HEMOSTASIS DEVICES\nItem No. 2: PHARMACOLOGICAL HEMOSTASIS- LIQUID BASED PROCOAGULANT SOLUTION FOR USE FOLLOWING TRANSFEMORAL INTERVENTION item233 1 pices
234 234 GROUP B12 HEMOSTASIS DEVICES\nItem No. 3: PHARMACOLOGICAL HEMOSTASIS - TOPICAL DRY PAD/BANDAGE BASED MECHANISM FOR USE FOLLOWING TRANSFEMORAL INTERVENTION item234 1 pices
235 235 GROUP B12 HEMOSTASIS DEVICES\nItem No. 4: FEMORAL COMPRESSION DEVICES - DISC/DOME BASED COMPRESSION item235 1 pices
236 236 GROUP B12 HEMOSTASIS DEVICES\nItem No. 5: DISCS/DOMES OF FEMORAL COMPRESSION DEVICES item236 1 pices
237 237 GROUP B12 HEMOSTASIS DEVICES\nItem No. 6: FEMORAL COMPRESSION DEVICES - INFLATABLE BALLOON BASED COMPRESSION item237 1 pices
238 238 GROUP B12 HEMOSTASIS DEVICES\nItem No. 7: DISPOSABLE FEMORAL COMPRESSION DEVICES - INFLATABLE BALLOON BASED COMPRESSION item238 1 pices
239 239 GROUP B12 HEMOSTASIS DEVICES\nItem No. 8: HANDHELD EXTERNAL FEMORAL COMPRESSION ASSISTING DEVICE item239 1 pices
240 240 GROUP B12 HEMOSTASIS DEVICES\nItem No. 9: RADIAL ARTERY COMPRESSOR - BALLOON BASED item240 1 pices
241 241 GROUP B12 HEMOSTASIS DEVICES\nItem No. 10: SPECIAL RADIAL ARTERY COMPRESSOR - BALLOON BASED WITH DOUBLE BALLOON TECHNOLOGY item241 1 pices
242 242 GROUP B12 HEMOSTASIS DEVICES\nItem No. 11: RADIAL ARTERY COMPRESSOR - STRAP BASED item242 1 pices
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail