Military Engineer Services-MES has published Joint Filling Of Runway And Taxi Track And Other B/R Work In 665 And 201 Army Avn Sqn Area Under Ge Nasik Road Camp As Per Tender Documents. Submission Date for this Tender is 21-01-2021. Runway Tenders in Garrison Engineer Nasik Road Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 14-Jan-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-01-2021 |
Name of Work: JOINT FILLING OF RUNWAYS TAXI TRACK AND OTHER B/R WORKS IN 665 AND 201 ARMY AVN SQN AREA UNDER AGE B/R LEKHANAGAR AT GE NASIK ROAD CAMP. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Raking out existing construction joints/dummy joints 10mm wide X 25mm deep in concrete pavements, cleaning surfaces and sweeping to make the surface free from dust/dirt with air compressor/blower and reoving debris to a distance exceeding 200m form edge of pavement for disposal in low lying areas. | 1700 | 10RM | |
2 | 2 | Raking out existing expansion joints 20mm wide X 25mm deep in concrete pavements, cleaning surfaces and sweeping to make the surface free from dust/dirt with air compressor/blower and reoving debris to a distance exceeding 200m form edge of pavement for disposal in low lying areas. | 300 | 10RM | |
3 | 3 | Filling construction joints/ dummy joints 10mm wide X 25mm deep in concrete pavements with sealing compound Grade ‘B’ after applying primer to the sides of jopints as per manufacturer's instructions. | 1700 | 10RM | |
4 | 4 | Filling expansion joints 20mm wide X 25mm deep in concrete pavements with sealing compound Grade ‘B’ after applying primer to the sides of jopints as per manufacturer's instructions. | 300 | 10RM | |
5 | 5 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, GI/aluminium grid etc. | 250 | SQM | |
6 | 6 | Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. "Make - Armstrong or equivalent" | 100 | SQM | |
7 | 7 | 12mm thick seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately)\n"Make - Gyp Board of Saint Gobain or equivalent". | 50 | SQM | |
8 | 8 | 6mm and thick PVC multiwall 250mm wide (tongue and groove interlocking type) panels, textured on one side (as approved); fixed to GI framework in ceiling with countersunk screws and inerlocked, including all necessary special fitting accessories such as junction, corner and turning matching to board.\n(GI framework to be measured and paid separately) | 50 | SQM | |
9 | 9 | 8mm and thick PVC multiwall 250mm wide (tongue and groove interlocking type) panels wall lining including necessary framework and fixing at site on PVC frame as per specifications.\n | 150 | SQM | |
10 | 10 | M&L for Laminate of HDF based tonge and furrow interlocking deck framework in size of 4' x 8" in board structure on wall or in flooring, tough surface scratches, blazes & stains resistant consisting of aluminium oxide covered tissue over printed decorative paper layer to gives the decor of wood grain, core domprising of HDF 8 mm thick over and including 10 mm thick plywood and balancing paper to lends balance to the construction preventing warpage fixed on wall and floor. | 70 | SQM | |
11 | 11 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings. | 150 | SQM | |
12 | 12 | Dismantling wrought iron or mild steel work of any description such as purlins ofor roof and window guard bars. | 4 | QTL | |
13 | 13 | Supply and fixing steel work in tubular or rectangular hollow section in rafters, purlins etc. and connected works complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 | 510 | KG | |
14 | 14 | Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified | 100 | SQM | |
15 | 15 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified | 10 | SQM | |
16 | 16 | S & F to mild steel framework 6mm thick multiwall polycarbonate sheet in roof or wall cladding fixed with aluminium clutch/tee EPDM gasket and self tapping screws. | 40 | SQM | |
17 | 17 | Preperation of new untreated steel or iron surfaces of any description over 10cm girth or width, not otherwise described and two coats of synthetic enemel paint over a coat of red oxide, zinc chrome primer. | 30 | SQM | |
18 | 18 | Taking down aluminium door shutters of any description. | 5 | SQM | |
19 | 19 | Taking down aluminium window shutters of any description. | 10 | SQM | |
20 | 20 | Taking down aluminium door and window frame of any description. | 25 | RM | |
21 | 21 | Aluminium (minimum 50 micron powder coated) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. | 30 | KG | |
22 | 22 | Aluminium (minimum 50 micron powder coated) door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. | 5 | SQM | |
23 | 23 | Aluminium (minimum 50 micron powder coated) window and ventilator shutters, side hung/sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinges type B-21, 100mm long (2 Nos.), suitable handle (1 No.), rollers, grip etc. complete all as specified | 10 | SQM | |
24 | 24 | 5.5mm thick sheet glass plain or tinted, ordinary quality, fixed in aluminium doors and windows. | 10 | SQM | |
25 | 25 | Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple or fixed in alumionium frames. | 4 | SQM | |
26 | 26 | Floor door closer hydraulically regulated, universal type (cast iron body) suitable for aluminium door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed | 3 | EACH | |
27 | 27 | M&l for preparation of old or previously treated steel or iron surfaces of any description over 10 cm width or girth and two coats of aluminium paint over a coat of red oxide primer. | 1200 | SQM | |
28 | 28 | M&L for removing existing layer of acrylic coating and applying 8 layer multipurpose court system as follows :-\n(i) ACRYPATCH - 100% ACRYFLEX based emulsion to repair cracks of concrete and asphalt pavement.\n(ii) PRIMER - 100% ACRYFLEX UNIC FLOOR based emulsion to improve bond of acrylic court system to the concrete or asphalt surface.\n(iii) RESURFACER - 2 ACRYFLEX resurfacer 367-30 for filling and smoothing asphalt or concrete surfaces in preparation for Acryflex ITF approved court system and also fills the surface chips, voids and conceals repairs while providing a smooth surface for colour coating.\n(iv) CUSHION COAT - 3 layers of Acryflex unic floor cushion for asphalt or concrete surfaces in preparation for Acryflex ITF approved system.\n(v) PRECOAT - 2 layers of Acryflex unic floor based textured court topcoat idle for colour coating tennis and basketball courts and other sport pavement surface. \n(vi) OVERLINE - 100% Acryflex unic floor based high hiding line paints.\nNote : PVC chicken wiremess is included in this rate. Wiremess shall be used to prevent the cracks below cushioning coat.\n | 1250 | SQM | |
29 | 29 | Demolition of cement concrete in ground floors and pavings n. exc 15 Cm thickness (below or above ground level). | 1 | CUM | |
30 | 30 | 75 mm thick cement concrete 1:4:8 type D2 (40 mm graded aggregate) in sub floor. | 15 | 15 | SQM |
31 | 31 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provided for. | 0.5 | CUM | |
32 | 32 | Providing cement concrete 1:2:4 type B0 (12.5 mm graded aggregate) in roof kerb or mud stops, rounded or chamfered on edges. | 0.5 | CUM | |
33 | 33 | NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS. 10,350.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ. |