Repair And Maintenance To Street Lights , Flood Lights , High Mast Lights , Security Lights And Dg Sets At Ctw , Ins Viswakarma , Bv Yard , Old Mo V , Abe Park And Cqae Under Age E/M No-Ii Of Ge ( U-I ) , Visakhapatnam, Garrison Engineer Utility-I Visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Repair And Maintenance To Street Lights , Flood Lights , High Mast Lights , Security Lights And Dg Sets At Ctw , Ins Viswakarma , Bv Yard , Old Mo V , Abe Park And Cqae Under Age E/M No-Ii Of Ge ( U-I ) , Visakhapatnam. Submission Date for this Tender is 19-01-2021. Halogen Light Tenders in Garrison Engineer Utility-I Visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26458310
Repair And Maintenance To Street Lights , Flood Lights , High Mast Lights , Security Lights And Dg Sets At Ctw , Ins Viswakarma , Bv Yard , Old Mo V , Abe Park And Cqae Under Age E/M No-Ii Of Ge ( U-I ) , Visakhapatnam
Open Tender
Indian
Andhra Pradesh
Garrison Engineer Utility-I Visakhapatnam
19-01-2021

Tender Details

Repair And Maintenance To Street Lights , Flood Lights , High Mast Lights , Security Lights And Dg Sets At Ctw , Ins Viswakarma , Bv Yard , Old Mo V , Abe Park And Cqae Under Age E / M No-Ii Of Ge ( U-I ) , Visakhapatnam

Key Value

Document Fees
INR 500 /-
EMD
INR 75000.0 /-
Tender Value
INR 37.50 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR AND MAINTENANCE TO STREET LIGHTS, FLOOD LIGHTS, HIGH MAST LIGHTS, SECURITY LIGHTS AND DG SETS AT CTW, INS VISWAKARMA, BV YARD, OLD MO (V), ABE PARK AND CQAE UNDER AGE E/M NO-II OF GE(U-I), VISAKHAPATNAM
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches n.exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in soft/loose soil complete all as directed by Engineer-in-Charge. 170 CUM
2 2 Returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as directed by Engineer-in-Charge. 98 CUM
3 3 Removal of surplus excavated material of any type not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as directed by Engineer-in-Charge. 72 CUM
4 4 M&L for Sand cushioning/sand covering for underground cable protection complete all as specified and directed by Engineer-in-Charge.\nNote: Punned thickness shall only be measured and paid. 60 CUM
5 5 Supply and laying sub class 'B' bricks of old size (approved size locally available) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge 7000 EACH
6 6 M&L for GI pipe light grade 50 mm dia laid along road crossings / plinth protection with suitable fittings for cable protection or fixed to the pole/ Wall complete all as specified and directed by Engineer-in-Charge .\nMake : Surya Roshni Ltd / Tata / Jindal steel / Prakash\n 24 RM
7 7 Supply and fix in replacement Electronic Timer suitable for street light timer panel / DG AMF panel / Star Delta Starter panel all as directed . \nMake: L&T/ Indoasian/GE/BCH. 5 EACH
8 8 Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commissioning complete all as directed by Engineer-in-Charge.\nNote:\na) The replaced Items like ballast, lamp, igniters, capacitors, electronic drivers, surge protection devices etc shall be measured and paid separately under relevant items under this Schedule.\nb) Necessary tools like ladders/cranes/manipuilators & other T&P required etc shall be arranged by the Contractor. \nc) The rate quoted deemed to be inclusive for minor parts viz. Nut bolts, circle clips, clamps etc if any required at site.\nd) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately. 300 JOB
9 9 Supply only the following spares suitable for street light/food light/post top lantern light fittings. \nMake: GE/Havells/CG/Goldwyn/Bajaj/Philips/Surya
10 9.01 Electronic driver suitable for 90 to 100 W LED light fitting 60 EACH
11 9.02 Electronic driver suitable for 70 to 80 W LED light fitting 55 EACH
12 9.03 Electronic driver suitable for 110 to 150 W LED light fitting 45 EACH
13 9.04 Surge protection device of capacity 10 KV suitable for LED light fitting 120 EACH
14 10 Dismantling LED light fitting of any make and of capacity 70 to 80 W, strip opening the electronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as directed by Engineer-in-Charge.\nNote : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items 55 JOB
15 11 Dismantling LED light fitting of any make and of capacity 90 to 100 W, strip opening the electronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as directed by Engineer-in-Charge.\nNote : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items 60 JOB
16 12 Dismantling LED light fitting of any make and of capacity 110 to 150 W, strip opening the electronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as directed by Engineer-in-Charge. \nNote : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items 45 JOB
17 13 Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 8500 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV including necessary clamps etc complete and testing on completion all as specified and as directed.\n(Make: ENDURAPEARLMAGNUMSL 100WLED757PASYTOTG of Havells or equivalent in Philips / Bajaj / Wipro / GE / CG). \nNote: The GI pipe bracket if required will be measured and paid separately under relevant items 16 EACH
18 14 Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV including necessary clamps etc complete and testing on completion all as specified and as directed.\n(Make: ENDURAPEARLMAGNUMSL 110WLED757PASYTOTG of Havells or equivalent in Philips / Bajaj / Wipro / GE / CG). \nNote: The GI pipe bracket if required will be measured and paid separately under relevant schedule items 16 EACH
19 15 Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV including necessary clamps etc complete and testing on completion all as specified and as directed.\n(Make: ENDURAPEARLMAGNUMSL 120WLED757PASYTOTG of Havells or equivalent in Philips / Bajaj / Wipro / GE / CG). \nNote: The GI pipe bracket if required will be measured and paid separately under relevant schedule items 14 EACH
20 16 Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 15000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65/66 and SPD of capacity 10 KV including necessary clamps etc complete and testing on completion all as specified and as directed.\n(Make: ENDURAPULSENSL150WLED757PASYBOTG of Havells or equivalent in Philips / Bajaj / Wipro / GE / CG). \nNote: The GI pipe bracket if required will be measured and paid separately under relevant schedule items 14 EACH
21 17 Dismantling old unserviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65 and surge protection device of 10 KV capacity etc including necessary angle iron supports , clamps etc complete and testing on completion all as specified and as directed \n(Make: JETAIRISFLS 100WLED757ASYMLTG of Havells or equivalent in Philips / Bajaj / Wipro / GE / CG). 16 EACH
22 18 Dismantling old un-serviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed.\n(Make: JETAIRISFLS 120WLED757ASYMLTG of Havells or equivalent in Philips / Bajaj / Wipro / GE / CG). 15 EACH
23 19 Taking down old unserviceable post top lantern fittings and Supply & fixing post top luminarie LED type of 40 W with IP 65 protection with die cast aluminium graphite grey powder coated finished body , polycarbonate opal diffuser, low power warm white (WW) LEDs with better heat dissipation, high efficient constant current electronic driver having operating voltage range from 140 to 280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 10 KV etc complete suitable for 60 mm OD pipe entry including suitable size loop in loop out boxes & flexible 3 core 1.5 Sqmm copper connecting cable from loop in loop out box to fitting etc complete all as specified & directed. \n(Make: Havells / Philips / Bajaj / Wipro / GE / CG). \nNote: The GI pipe if required will be measured and paid separately under relevant schedule items 6 EACH
24 20 Taking down old unserviceable post top lantern fittings and Supply & fixing post top luminarie LED type of 60 W with IP 65 protection with die cast aluminium graphite grey powder coated finished body , polycarbonate opal diffuser, low power warm white (WW) LEDs with better heat dissipation, high efficient constant current electronic driver having operating voltage range from 140 to 280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 10 KV etc complete suitable for 60 mm OD pipe entry including suitable size loop in loop out boxes & flexible 3 core 1.5 Sqmm copper connecting cable from loop in loop out box to fitting etc complete all as directed & specified. \n(Make: Havells / Philips / Bajaj / Wipro / GE / CG). \nNote: The GI pipe if required will be measured and paid separately under relevant schedule items 6 EACH
25 21 Supply & lay or fixing or passing through pipe or in cable ducts, 1100 volts grade, XLPE insulaed, armoured, electric power cables (heavy duty) with aluminium conductor of the following size including taking down old one complete all as directed by Engineer-in-Charge. \nMake: Havells/ Gloster/ Polycab/ Nicco
26 21.01 25 Sqmm 4 Core 350 RM
27 21.02 16 Sqmm 4 core 350 RM
28 21.03 10 Sqmm 4 core 300 RM
29 22 Supply and erection, testing and commissioning of Hot dip galvanised octagonal pole of 7.5 m height, top dia 70 mm dia bottom dia 135 mm, Base plate 225mm x 225 mm x 16 mm, foundation bolt M20 x 700 - 04 Nos complete with single arm GI bracket of suitable size and including built in connecter control box with locking arrangement along with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box and flexible 3 core 1.5 Sqmm copper connecting cable from control box to fitting all as directed including dismantling old one complete all as specified and directed. \nMake: C&N / Utkarsh / GE or equivalent.\nNote :- Earth work, Cement concrete in foundation etc will be measured and paid separately under relevant item. 8 EACH
30 23 S&F in repair PVC insulated 3 core 1.5 Sq mm stranded copper conductor flexible cable for connecting junction box to street light fitting testing and commissioning complete all as directed by Engineer-in-Charge.\nMake: Gloster/Polycab/Havell/ Finolex 300 RM
31 24 Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings complete all as directed. 4 CUM
32 25 M&L for PCC 1:3:6 Type C2 using 20 mm graded stone aggregate as in coping of poles and stay assemble including necessary form work and dismantling of old broken coping complete all as specified and directed. 8 CUM
33 26 Supply and fixing timelite distribution boards (street light DBs) 65 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one . Make: Indo Asian/ HPL/Havells 4 EACH
34 27 Earthing complete with Galvanised Steel earth plate of size 60x60cmx6.3mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing). 6 EACH
35 28 S&F loop-in/loop-out box of internal size 200x160x98 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01No, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to steel tubular pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed.\nMake :- Sintex/ Hensel 80 EACH
36 29 M&L for bracket of street light fitting made out of 40 mm bore GI pipe light grade bent to shape required, not less than 1.20 m long, fixed with and including MS flat iron clamps made out of 40 x 6 mm FI, bolts, nuts, washers etc complete including dismantling old one complete all as specified and directed.\n( Make : Surya Roshni Ltd / Tata / Jindal steel / Prakash ) 8 EACH JOB
37 30 M&L for bracket of street light fitting made out of 25 mm bore GI pipe light grade bent to shape required, not less than 1.20 m long, fixed with and including MS flat iron clamps made out of 40 x 6 mm FI, bolts, nuts, washers etc complete including dismantling old one complete all as specified and directed.\n( Make : Surya Roshni Ltd / Tata / Jindal steel / Prakash ) 7 EACH JOB
38 31 M&L for preparation of old painted steel surfaces of 9 m long steel poles including removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with 125 mm dia adhesive sticker with white letters/ blackground etc complete all as directed 300 JOB
39 32 M&L for preparation of old painted steel surfaces of 11 m long steel poles including removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with 125 mm dia adhesive sticker with white letters/ background etc complete all as directed 30 JOB
40 33 M&L for fixing in repair adhesive sticker radium type red coloured water resistant of approx 2 inches width around the circumference of pole at a approx height of two meters all as directed. 500 RM
41 34 Repairs to High Mast/mid mast pole motor of Capacity 1.0 HP/0.75 KW 415 Volts 50 Hz 3 Phase 930 RPM and necessary rewinding with super enameled copper wire all as per existing and servicing/greasing of reduction gear box complete all as specified and as directed by Engr-in-Charge. 2 EACH JOB
42 35 Repair/ Maintanence of the control panel of High mast/Mid mast and replacement of all unserviceable parts such as contactors/timers etc complete including painting with a coat of synthetic enamel paint 2 EACH JOB
43 36 Repairs to High Mast/mid mast of 12.5 Mtr to 16 Mtr height lantern carriage/winch, checking for movement, inspecting the alignment, replacement of broken/defective SS wire roper of size 6 mm 7/19 construction complete, replacement of 5 core 2.5 Sqmm flexible copper conductor, ERP insulated PCP/PVC sheathed trailing cable complete, testing & commissioning complete all as directed by Engr-in-Charge 1 JOB
44 37 S&F in repair MCB single pole of capacity 6 to 32 Amps. \nMake: GE /L&T//Havells/C&S/Schneider 20 EACH
45 38 M&L for De-scaling of radiator by dismantling the upper & lower tank and cleaning the core pipes with cleaning chemicals (radi wash), components and arrest the leaking core by brazing/ dummy with lead including cleaning of upper and lower tanks and replacing the upper and lower gaskets and required nuts, bolts, refixing the same including testing and painting of 125 KVA capacity complete all as specified and directed 2 EACH JOB
46 39 M&L for carrying out 'B' check for DG set 125 KVA, as per manufacturer's recommendation including replacement of filter, 'O' rings, engine oil, gasket, coolant etc complete. Make of Engine: Kirloskar/ CUMMINS/ ASHOK LEYLAND/Greaves 2 EACH JOB
47 40 Repair/Servicing of AMF panel to 125 KVA DG set with microprocessor controller suitable electrical and DG controls and auto / manual and bypass arrangement complete with suitable capacity 4 pole power contactors, DG controls and auto / manual mode complete with (i) AMF relay ( SCADA Compatible auto synchornising relay) , (ii) meters,enery meter,AVF meter (iii) on delay timer,(iv)slector switches,(v) 24 V, 10 A, SMPSS based automatic float cum boost charge type Battery charger,(vi) auxiliary contactors,(vii) push buttons with No,NC elememts, (viii) LED indication lamps, (ix) DC hooter and control wiring from DG set to panel, necessary additions/ alterations any required to DG set for making suitble for AMF operation complete including testing, commissioning complete etc all as directed. 1 EACH
48 41 Disconnecting and removing existing unserviceable battery and S&F maintenance free battery 12V 180 AH including terminal clamps, copper lead of suitable length including testing and commissioning all as directed by Engineer-in-Charge. [Make: Exide/ Amara Raja/ Tata Green] 2 EACH
49 42 M&L for preparation of old painted steel surfaces of 125 KVA capacity DG sets including alternator, radiator support channels complete, connected equipments complete and painting with two coats of approved colour synthetic enamel paint complete all as directed. 1 EACH JOB
50 43 S&F in repair AVR with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator droop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set intial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max upto 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG sets of capacity 125 KVA to 320 KVA 2 JOB
51 44 Supply only rubber hose pipe including clamps for 125 KVA to 320 KVA suitable length as per site requirement for radiatior and cooling system 2 EACH SET
52 45 Battery lead for 180 AH 12 volts batteries with thimble length not less than 1 m each (01 with Red colour Insulating cover for positive terminal and 1 with Black Insulating cover for negative teminal ) complete all as specified and directed. 2 EACH SET
53 46 S & F of Water pump for 125 KVA DG sets cummins complete all as specified and directed. 2 EACH
54 47 S & F of self starter 24 Volt of existing Make all as directed. 2 EACH
55 48 Repair to fuel water separator assembly complet all as directed. 2 EACH
56 49 Supply and fill of coolent sutable for DG Set all as directed. 40 LITRE
57 50 S & F Air Filter for DG Set of capacity 125 KVA as approved and directed. 2 EACH