Special Repair To Replacement Of Ber Window/ Split Type Ac And Summer Appliances And Provn Of Servo Controlled Voltage Stabilizer For Lift Block No . 1 To 10 , 12A , And 13A At Arjan Vihar Under Ge Utility Plant And Machinery Delhi Cantt-10, DELHI CANTT-Delhi

Military Engineer Services-MES has published Special Repair To Replacement Of Ber Window/ Split Type Ac And Summer Appliances And Provn Of Servo Controlled Voltage Stabilizer For Lift Block No . 1 To 10 , 12A , And 13A At Arjan Vihar Under Ge Utility Plant And Machinery Delhi Cantt-10. Submission Date for this Tender is 21-01-2021. Voltage Stabiliser Tenders in DELHI CANTT Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

26432603
Corrigendum : Special Repair To Replacement Of Ber Window/ Split Type Ac And Summer Appliances And Provn Of Servo Controlled Voltage Stabilizer For Lift Block No . 1 To 10 , 12A , And 13A At Arjan Vihar Under Ge Utility Plant And Machinery Delhi Cantt-10
Open Tender
Indian
Delhi
DELHI CANTT
21-01-2021

Tender Details

Special Repair To Replacement Of Ber Window / Split Type Ac And Summer Appliances And Provn Of Servo Controlled Voltage Stabilizer For Lift Block No . 1 To 10 , 12A , And 13A At Arjan Vihar Under Ge Utility Plant And Machinery Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Jan-2021 Corrigendum No 1 Date 14-01-2021
2 14-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-01-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 86380.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SPECIAL REPAIR TO REPLACEMENT OF BER WINDOW/ SPLIT TYPE AC AND SUMMER APPLIANCES AND PROVN OF SERVO CONTROLLED VOLTAGE STABILIZER FOR LIFT BLOCK NO. 1 TO 10, 12A, AND 13A AT ARJAN VIHAR UNDER GE(U) P&M DELHI CANTT-10.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SECTION-I (AC WORKS)
2 2 Supply, Installation, commissioning and testing of Inverter Technology Hot & Cold Split Type wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Capacity not less than 1.5 TR, BEE 5 star rating , fitted with rotary compressor (5 years Warranty), Refrigerant type R-410A/R-32, cooling capacity nominal (4500 Kcl/Hrs) including outdoor stand (Wall mounted/ Floor mounted), PVC FRLS grade multi stranded copper conductor cable 4 core 2.5 Sqmm for connections with outdoor unit, powder coated brackets for outdoor unit, clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall/ ceiling with cement mortar, white cement and painting work to match the existing surfaces of walls complete all as specified and directed. (Make:- Model No. FTXF50TV16 (Inverter Hot & Cold) of Daikin/ Model No. ASGG18LFCDB (Inverter Hot & Cold) of O-General/ Model No. RSOG517HDXA (Inverter Hot & Cold) of Hitachi or equivalent model of make Blue Star.)\n 25 Each
3 3 Supply, Installation, commissioning and testing of Inverter Technology Hot & Cold Split Type wall mounted Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Capacity not less than 2.0 TR, minimum BEE 4 star rating , fitted with rotary compressor (5 year Warranty), Refrigerant type R-410A/R-32, cooling capacity nominal (6000 Kcl/Hrs) including outdoor stand (Wall mounted/ Floor mounted), PVC FRLS grade multi stranded copper conductor cable 4 core 2.5 Sqmm for connections with outdoor unit, Powder coated brackets for outdoor unit, clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall/ ceiling with cement mortar, white cement and painting work to match the existing surfaces of walls complete all as specified and directed. \n(Make:- Model No. FTXF71TV (Inverter Hot & Cold) of Daikin/ Model No. ASGG24LFCD (Inverter Hot & Cold) of O-General/ Model No. RMOG422HDXA (Inverter Hot & Cold) of Hitachi or equivalent model of make Blue Star.)\nNote for item No. 1 & 2:- (i) PVC drain pipe of suitable size & Heavy Duty copper connection pipes including suitable insulation upto 3 mtrs are deemed to be included in above quoted rate.\n(ii) PVC drain pipe of suitable size & Heavy duty copper connection pipes including suitable insulation Exceeding 3 mtrs shall be measured and paid seperately under relevant item. 14 Each
4 4 Supply, Installation, commissioning and testing of window type Air Conditioner of capacity 1.5 TR, BEE not less than 5 star raing, Refrigerant type R-410A/R-32, fitted with highly energy efficient inverter compressor, including making necessary arrangements like cutting existing grills for fixing of window and making good the disturbed surfaces surfaces complete all as specified and as directed. (Make:- Model No. FRWF50TV162 of Daikin/ Model No. 185V DZA of Voltas/ Model No. 5W18GBTI of Blue Star or equivalent model of make Hitachi.)\nNote :- (i) Rate quoted by the contractor shall deemed to be included the disconnection of existing old Acs split/ window type any capacity fron site of installation and transporting to AGE E/M (AC) store yard for depositing in store. 11 Each
5 5 Supply and fixing Single pole and neutral steel metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps including taking down old one complete all as specified and directed by Engr-in-Charge. (Make : LEGRAND/ L&T / ABB/SEIMENS.) 40 Each
6 6 Taking down unserviceable sub main wiring of any type and any size including wooden batten, PVC conduit or casing caping complete all as specified and as directed. 300 Rm
7 7 Material and labour for AC sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC casing caping (medium grade) of adequit size with all fittings and accessories surface type including one run 4 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed. 150 RM
8 8 Material and labour for AC sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC casing caping (medium grade) of adequit size with all fittings and accessories surface type including one run 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed. {Note for item No. 7 & 8:- (i) Two runs of cable with one run earth wire and PVC casing caping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing caping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth. (v) (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD and make of Casing Caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)} 150 RM
9 9 Supply & fixing in repairs heavy duty copper pipe of size 6mm (1/4") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size complete all as specified and directed by Engr-in-Charge. (Make:- DIAMOND/ STAR) 30 RM
10 10 -ditto- all as per item No. 9 above but copper pipe of size 12mm (1/2") dia/ bore. 25 RM
11 11 -ditto- all as per item No. 9 above but copper pipe of size 15mm (5/8") dia/ bore. 15 RM
12 12 M&L for exterior grade veneered decorative 4 mm thick plywood of grade BWR, with decorative face veneers on both faces fixed with screws to timber frame work including teak wood beadding of suitable size as required at site to cover up void portion left after installation/ removing of window type AC and other necessary fixing accessories and applying two coat of synthetic enamel paint ( 1st grade quality) over a coat of pink primer complete all as specified & as directed. (Make:- Century/ Dura/ Green ply/ Kitply.) 12 10 Sqm
13 13 Supply and fixing powder coated brackets for out door unit complete with fixing nuts, bolts, washers, drilling holes/ grouting on wall complete all as specified and as directed. 20 Set
14 14 SECTION-II (SERVO CONTROLLED VOLTAGE STABILIZER)
15 15 Supply install,testing and commissioning of copper wounded servo voltage stabilizer , 3Phase,4 wire AC supply with 50HZ frequency for automatic operation naturally oil cooled designed (for Unbalanced input and unbalanced load ) for input variation between 360V to 480V ,3 Phase,4 wire 50Hz ,AC with output voltage stabilized at 415V +/- 1% (adjustable ) 3phase 4wire AC and speed of correction 8 voltage per sec for single phase, indoor type floor mounted canopy as per IS:9815 (Part-I) of capacity of 20 KVA Suitable for operation between 0 to 50 degree Celsius ambient temperature and conforming to BIS 9815: part - I :1994 reaffirmed 2009, The servo stablizer for easy movement complete all as specified and including the following features :- \n(I) waveform distortion should be Nil. \n(II) Efficiency shall be more than 97% on full load.\n(III) Response time not to exceed 10MS . \n(IV) Immune to load PF & Supply frequency variations. \n(V) Following protection should be provided :-\n\n(a) Automatic low/high voltage cut off in the output with audio visual alarm cum cancellation and acknowledgment facility.\n(b) Short circuit protection ineach phase with Led indicator lamps and with a common ACB ,4 Pole of Make -L&T,English Electric of suitable capacity to trip of the output when the input supply /load goes beyond limits. \n(c) Single Phaseing protection (phase missing/phasereversal alarm and cut off. \n(VI) Output voltage setting (by potentiometer in AUTO mode & by Raise/lower push button in manual mode). 12 Each
16 16 (VII) Operation Auto/Manual. \n(VIII)Power loss should be less than 3% at full load. \n(IX) No load losses should be less than 1%. \n(X) Metering : Digital type AC Voltmeter & Ammeter with selector switch ,digital type ferquency meter , Phase sequence indicator stablizer shall be provided with sutible capacity four pole on load by pass switch to isolate the AVR and By pass the mainsMake:- L&T,HPL,C&S,Havells)\n(i) Motorixed variable auto tranformer ,wound on tororized CRGO laminations with high quality graphite carbon for smooth function-03Nos (one for each Phase). \n(j) Digital micro contolled processor based control card with push buttons for operations -03Nos (one for each Phase).\n(k) AC synchronous servo motor - 03Nos (one for each Phase).\n(l) Boost series transformer - 03Nos (one for each Phase) all this will be incorporated inside high quality powder coated (Siemens grey) Sheet steel tank with first fill tranformer oil (IS:1993 reaffirmed2005) and mounted on unidirectonal wheel and including lifting lugs,earting,rating plate and name plate,Voltage stablizer (Make - AE/APLAB/ ANDREW YULE /INDIAN TRANSFORMER & ELECTRICALS P.LTD (GURGAON) /V-GUARD/SINETRAC/ VOLINA/VINITEC/ IECO ).\nNOTE:- (i) The contractor shall arrange for factory visit for the rep of accepting officer for testing / inspection of servo voltage stablizer before dispatch at site.
17 17 M & L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32 x 6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth worl in soft/loose soil,returning filling,disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20 mm graded stone aggregate pit, funnel, 20 mm dia GI medium grade watering pipe, 15 mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50 mm thick made of RCC 1:1.5:3 type A1 duly reinforced with 8mm dia TMT bar @ 100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick complete all as specified and directed. (Make of GI Pipe:- Jindal/TATA/BST/PRAKASH TUBES/OSWAL) (Notes:- Each protecton pipe and earthing lead upto and including 7.5 m length id deemed to be included in quoted rate of this item.) 24 Each Set
18 18 M & L of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc using 32 x 6mm galvanised iron strip complete all as & specified & directed by Engr-in-charge. 410 RM
19 19 Supply,laying & fixing XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 Core laid on trench/wall/floor including nesessary clamps,cable lugs,glands,accessories etc complete all as specified & directed by Engr-in-charge.(Make:- FINOLEX/ R R KABEL/ KALINGA/ PLAZA / POLYCAB/ HAVELLS) 740 RM
20 20 Supply & fixing MCCB 63 amp 4 pole, 415 voltAC,16KA with enclosures Box (SS Box)including necessary clamps, cable lugs, glands, accessories etc. complete all as specified & directed by Engr-in-charge.(Make:- L&T/ SIEMENS/LEGRAND/ ABB ). 12 Each