Military Engineer Services-MES has published Repair To Joinery Mp Tiles And Water Proofing Treatments And Other Misc Works To Certain Buildings At Nsry And Repair To Wooden Sleepers , Ms Steel , Gunting And Some Misc Works At South Jetty And North Jetty At Naval Base Kochi Under Ge Nw Kochi. Submission Date for this Tender is 20-01-2021. Water Proofing Work Tenders in KOCHI Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 13-Jan-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-01-2021 |
Name of Work :- REPAIR TO JOINERY MP TILES AND WATER PROOFING TREATMENTS AND OTHER MISC WORKS TO CERTAIN BUILDINGS AT NSRY AND REPAIR TO WOODEN SLEEPERS, MS STEEL, GUNTING AND SOME MISC WORKS AT SOUTH JETTY AND NORTH JETTY AT NAVAL BASE KOCHI UNDER GE NW KOCHI | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling asbestos cement (corrugated, semi-corrugated, etc) sheets in roof coverings height up to 15 mtrs | 250 | Square Metre | |
2 | 2 | Dismantling of plain or corrugated steel sheeting any gauge, thickness including nanital or similar pattern roof covering complete | 220 | Square Metre | |
3 | 3 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. | 240 | Square Metre | |
4 | 4 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed . | 1 | Cubic Metre | |
5 | 5 | M & L for brickwork with sub class B bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed . | 1 | Cubic Metre | |
6 | 6 | Demolition of pre cast cement concrete block masonry, built in cement mortar including all quoins, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed . | 4.5 | Cubic Metre | |
7 | 7 | M&L for pre-cast cement concrete block masonry in 1:3:6 Type C 1, (20mm graded aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified | 4.5 | Cubic Metre | |
8 | 8 | Demolition of plain cement Concrete of any description and in any positionnot otherwise specially provided for complete all as specified and as directed . | 5.5 | Cubic Metre | |
9 | 9 | Demolition of reinforced cement Concrete of any description and in any positionnot otherwise specially provided for complete all as specified and as directed . | 1 | Cubic Metre | |
10 | 10 | M&L for 75 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base of hard standing all as specified and directed . | 80 | Square Metre | |
11 | 11 | M&L for 50mm thick Cement concrete type B- 1, 1:2:4 (20mm graded aggregate) laid in bays in floor/paving/hard standing and similar work, finishing cement concrete surface even and smooth with out using extra cement complete all as specified and directed | 80 | Square Metre | |
12 | 12 | S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws(Height up to 15 Mtrs) complete all as specified and directed | 250 | Square Metre | |
13 | 13 | S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/roof ridge, fixed with self tapping screws (Height up to 15 Mtrs) complete all as specified and directed | 25 | Square Metre | |
14 | 14 | S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with with L-type or J-type or self taping screws etc as in roof, wall etc (Height up to 15 Mtrs) complete all as specified and directed | 100 | Square Metre | |
15 | 15 | M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with L type or J type or cranked hook bolts (Height up to 15 Mtrs) complete all as specified and directed | 80 | Square Metre | |
16 | 16 | M&L for Asbestos cement onepiece plain angular ridge 6mm thick thick fixed with L type or J type or cranked hook bolts (Height up to 15 Mtrs) complete all as specified and directed | 30 | Running Metre | |
17 | 17 | Labour only for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with L type or J type or cranked hook bolts (Height up to 15 Mtrs) complete all as specified and directed | 40 | Square Metre | |
18 | 18 | Dismantling of Wall or ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets etc , keep in safe custody for reuse complete all as specified and directed. | 100 | Square Metre | |
19 | 19 | S&F interlocking aluminium alloy anodized snap grid for ceiling consists of main Tee runners of size 38mm x 25mm x 1.5mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x 1.5mm, 1200mm long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Tee 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 32mm x 32mm x 1.5mm. Aluminium alloy extruded section shall be aluminium anodized (minimum 15 micron) and shall conform to IS-733, IS-1285 and IS-737 all as specified and as directed | 100 | Square Metre | |
20 | 20 | M&L for Hangers 3 mm to 4 mm mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. | 100 | Square Metre | |
21 | 21 | M&L for 4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws all as specified and as directed. | 100 | Square Metre | |
22 | 22 | M&L preparing new surfaces of ceilling and applying two coats of white wash, complete all as specified and as directed. | 100 | Square Metre | |
23 | 23 | M&L for 15mm thick rendering on brick or concrete wall surfaces with cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and as directed . | 200 | Square Metre | |
24 | 24 | M&L preparing new surfaces of wall and applying two coats of white wash, complete all as specified and as directed. | 100 | Square Metre | |
25 | 25 | M & L for preparation of new wall surfaces and applying of two coats of oil bound distemper over a coat of primer complete all as specified | 100 | Square Metre | |
26 | 26 | Taking down existing roof treatment including roof tiles,plaster and cleaning the surface with wire bush and removed all dirt,dust etc complete all as specified and as directed. | 150 | Square Metre | |
27 | 27 | M&L for Plain Cement Concrete 1:2:4, type B0 using 12.5mm graded stone aggregate for levelling course on roof slab etc including necessary form work complete all as specified and as directed . | 7.5 | Cubic Metre | |
28 | 28 | M&L Rendering 20mm thick on concrete surface in cement mortar 1:4 with water proofing compound,over neat cement slurry with 3.0 Kg of cement per sq.metre including finishing plastered surfaces even and smooth without using extra cement complete. complete all as specified. [ Note: WPC shall be measured and paid seperataly.] | 150 | Square Metre | |
29 | 29 | M&L for applying bitumen primer 0.20 kg/sqm applying a coat of blown grade hot bitumen 90/15 over the primer @ 1.20 kg/sqm providing and laying 4mm thick APP modified water proofing membrane weighting not less than 4kg/sqm reinforced with woven polyster matt weighting not less than 160 gm/sqm having softening point not less than 650 N/Sqm tearing strength of 180 N by torch application including minimum 10 cm side over lap and 15 cm end laps applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.20 kg/sqm finishing with solar reflective bituminous aluminium paint @ 0.10 kg/sqm complete all as specified and as directed . | 150 | Square Metre | |
30 | 30 | Supply only Water Proofing compound, conforming to IS and as approved, complete all as specified. | 35 | Kilogram | |
31 | 31 | Supply and fix in repairs PVC semicircular eaves gutter 180mm dia in any length with rubber ring joints fixed complete with all fittings all as specified and as directed . | 75 | Running Metre | |
32 | 32 | Supply and fix in repairs 110 mm dia of PVC(SWR) pipes single socketed in any lengh with rubber ring joints fixed to wall complete all as specified . | 100 | Running Metre | |
33 | 33 | Supply and fix in repairs 110 mm dia bends with rubber ring joints fixed to wall complete all as specified . | 10 | Each | |
34 | 34 | Dismantling Single layer Mangalore pattern or similar tiles in roofing all as specified and as directed. | 50 | Square Metre | |
35 | 35 | Material and labour for Roof tiles, Mangalore pattern, interlocking at side joints, laid dry all as specified and as directed . | 30 | Square Metre | |
36 | 36 | All as item 35 above but except tiles | 20 | Square Metre | |
37 | 37 | Material and labour for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 all as specified and as directed . | 10 | Running Metre | |
38 | 38 | All as item 37 above but except tiles | 10 | Running Metre | |
39 | 39 | S&F mild steel work as in band, strap, hold fast, cleat, hook, hinges, base tie for foor frame, support or stay for rain water pipe etc and other similar items complete all as specified and as directed | 50 | Kilogram | |
40 | 40 | Dismantling structural steel work including doors, gates,etc all as specified and directed. | 3 | Quintal | |
41 | 41 | Material and labour for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 all as specified and as directed . | 300 | Kilogram | |
42 | 42 | Material and labour for preparing new steel surface of any description exc 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer all as specified and as directed. | 65 | Square Metre | |
43 | 43 | RemovaL of vegitation/ shurb growth over walls,roof chajja,gutter up to four storey building cleaning the surface and spraying acid of required concentration and quantity making good holes with cement mortar(1:3) or cement concretew 1:3:6 type C1 each hole not exceeding 0.10 sqm area including necessary scafolding etc complete all as specified and as directed . | 25 | Each | |
44 | 44 | S&Fin repair for 1.25 mm thk steel rolling shutters with out ball bearing as specified including top cover , anchoring rod,hasp and staple and one shop coat of primer erected in position as indicated complete ,push pull or manual type complete all as specified | 10 | Square Metre | |
45 | 45 | S&F in repairs for 1.00 mm thick plain galvanised mild steel sheeting top cover of rolling shutter complete all as specified | 5 | Square Metre | |
46 | 46 | S&F in repair of MS spring for rolling shutters complete all as specified | 15 | Each | |
47 | 47 | M&L for cleaning of rolling shutter and applying greasing on steel surfaces in side channels for smooth functioning of all steel members complete all as specified | 120 | Running Metre | |
48 | 48 | M&L for clean off all surface coating and stain around the leakage area. Study and determine leak pattern and establish leakage source. Drill injection ports at distance of 200mm c/c to intercept the leak paths. The injection ports shall be drilled at a depth required. Check for positive interception of injection ports on to leak path by observing for leakage diversion through injection ports. If leak is not detected in the injection ports, change location or angle and redrill. Onece positive interseption is confirmed, clean injection ports with water and install mchanical injection packers. Injection packers shall have check valve, which prevents back flush of grout and capable of holding pressure of up to 1050 PSI ( 7 N/sqmm). Pump water through injection packers to flush out leak path as well as saturate it with water (If necessary). Ceal off honey comb area or larger crake, which leak severly when pumed with water, with hydrwalik cement (if necessary). Pump the water reactive polyurethane grout thrugh injection packers to a prescribed pressure. As the grouts expand during the reaction with water, it is necessary to reterned to previously grouted points to check that the presceibed back pressure is mainted before grout is fully cured. Remove injection packer after the grout has fully cured. The quoted rate is inclusive of all labour invovle in drilling, fixing packer, injecting, removing, cealing,etc. chemical used Sika's Sika injection 101h & Sika injection 201 CE complete all as specified | 25 | Kilogram | |
49 | 49 | M&L for paker 14mm, 75mm, 110mm, 200mm dia of Nozzle as per required at site including make good the existing surface to match existing one complete all as spercified and as directed. | 20 | Per Nozzle | |
50 | 50 | M&L for forming 25mm thick expansion joint, cleaning the joint and filling the same with Colpar 200 (grey) of M/s FOSROC or equivalent up to 50 mm thick salb all as per manfacturers instruction complete all as spercified and as directed. | 40 | Running Metre | |
51 | 51 | M&L for forming Contraction (Dummy ) joints (10x15mm) cleaning the joint and filling with Colpar 200 (Grey) of M/s FOSROC or equivalent in BASF/STP all as per manufacturers instruction complete all as spercified and as directed. | 330 | Running Metre | |
52 | 52 | Dismantling timber scantlings 40 sqcm and over in section, in any position, complete all as spercified and as directed. | 4 | Cubic Metre | |
53 | 53 | M/LSecond class HW in scantling (wrought) fixed as in cope timber, cross section 300 mm x 200 mm complete all as spercified and as directed. | 4 | Cubic Metre | |
54 | 54 | Providing and fabricating and fixing reinforcement steel of TMT bars of specified diameter around the beams and tied/tack welded to shear connectors complete all as spercified and as directed. | 300 | Kilogram | |
55 | 55 | M&L for cleaning removal of rusted particles from reinforcement of any diameter using wire brush/emery paper or by grinding and applying Anticorrosive chemical of M/s BASF/FOSROC/STP complete all as spercified and as directed. | 30 | Square Metre | |
56 | 56 | Drilling of 12 mm dia 75 mm depth hole in concrete for fixing shear connectors at 600 mm c/c , using rotary-cum-hammering drilling machine with concrete drill bits. The drilled hole shall be cleaned thoroughly by water and air jet etc. complete all as spercified and as directed. | 100 | Each | |
57 | 57 | M&L for applying/injecting grouting with Epoxy resin bonding agent of M/s BASF/FOSROC/STP on existing surfaces of concrete after preparation of surfaces, prior to new concrete work as per manufactures instructions complete all as spercified and as directed. | 45 | Square Metre | |
58 | 58 | M&L for gunnitting concrete surface /under water 25 to 40 mm thick using GUNNABLE GRADE MICRO CONCRETE, applied with compressor after cleaning the surface, density of micro concrete not less than 2000kg/cum , strength not less than 25 Mpa and workmanship as per specifications including provision of necessary pontoons for easy working on water need to provide by contractor complete all as spercified and as directed. | 45 | Square Metre | |
59 | 59 | S&F in repairs fenders of size 2000mm length 450 mm external dia and 200 mm internal dia in repairs all as per directions complete all as spercified and as directed. | 2 | Each | |
60 | 60 | M&L Galvanised MS D/U Shackle 20 mm dia with locking bolt & nuts 16 mm dia complete all as spercified and as directed. | 20 | Each | |
61 | 61 | M&L for preparation of new wood surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified. | 80 | Square Metre | |
62 | 62 | M&L for preparation of old wood painted surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified. | 400 | Square Metre | |
63 | 63 | M&L for preparation of old decorated brick/concrete surfaces of any description exc 10 cm width or girth and applying two coat of synthetic enamel paint all as specified and directed. | 1400 | Square Metre | |
64 | 64 | M&L for gunniting concrete surface up to 40 mm thick with cement mortar using compressor in the ratio 1:2 over epoxy bonding agent applied on the existing surfaces of the concrete after cleaing and spraying with mortar complete as per specifications including provision of necessary pontoons for easy working on water need to provide by contractor complete all as specified and directed . | 200 | Square Metre | |
65 | 65 | S&F Chain 12mm dia of fender in repair all as specified and directed by engineer in charge . | 10 | Running Metre | |
66 | 66 | Dismantling floor, hearth or wall tiling,concrete block,paver block etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. | 40 | Square Metre | |
67 | 67 | M&L for screed bed or bedding layer of mortar, 20mm thick in cement mortar 1:6 for laying floor tiles etc complete all as specified and directed. | 40 | Square Metre | |
68 | 68 | Material and labour for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors, tiles of approved design/pattern with grey and white cement in equal proportion and no pigment all as specified and as directed . | 40 | Square Metre | |
69 | 69 | M&L for providing precast reinforced cement concrete in cover slabs, Type B1 1:2:4 using 20 mm graded aggregate set in cement mortar 1:4 complete all as specified | 2 | Cubic Metre | |
70 | 70 | Mild steel bars 6mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed . | 250 | Kilogram | |
71 | 71 | Mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed . | 80 | Kilogram | |
72 | 72 | Dismantling wrought iron or mild steel/SS work of any description not otherwise provided for all as specified and as directed | 10 | Quintal | |
73 | 73 | S&F M S Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work all as specified and as directed . | 60 | Kilogram | |
74 | 74 | S&F stainless steel rectangular/round tube any size/ any shape all as specified and directed | 60 | Kilogram | |
75 | 75 | M&L for preparation of old painted steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying a coat of synthetic enamel paint all as specified and directed . | 25 | Square Metre | |
76 | 76 | S&F MS Plates (plain or chequered) , channels, square cut or notched (ordinary and counter sunk) forming holes,confirming to Fe-290 (Gde E165)\nwithout any attachment all as specified and as directed . | 350 | Kilogram | |
77 | 77 | S&F rolled mild steel in joist,channel,angle,or tee sections fixed independently,without connecting plates ,etc confirming toFe-290 (Gde E165) as specified and as directed | 320 | Kilogram | |
78 | 78 | Demolition of Plain cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) incl removal of debrises to distance exc 50m and n exc 100m complete as specified and as directed | 3 | Cubic Metre |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail