Providing Of Swimming Pool At Ludhiana, Jalandhar Cantt-Punjab

Military Engineer Services-MES has published Providing Of Swimming Pool At Ludhiana. Submission Date for this Tender is 08-02-2021. Swimming Pool Construction Tenders in Jalandhar Cantt Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

26309203
Corrigendum : Providing Of Swimming Pool At Ludhiana
Open Tender
Indian
Punjab
Jalandhar Cantt
08-02-2021

Tender Details

Providing Of Swimming Pool At Ludhiana

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Jan-2021 Corridendum No 02 dated 18 Jan 2021 BOQ 01-02-2021
2 25-Jan-2021 Corrigedum No 03 dated 25 Jan 2021 Other 01-02-2021
3 29-Jan-2021 Corrigendum No 04 dated 29 Jan 2021 Date 08-02-2021

Key Value

Document Fees
INR 3000 /-
EMD
INR 650000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVN OF SWIMMING POOL AT LUDHIANA (Tender ID : 2018_MES_188939_1)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Note: (i) Please refer Schedule 'A' Notes given on serial page No. 22 to 26 of tender documents.\n(ii) Item from Srl No. 3.00 to 10.55 of this document shall be Part-XII (Miscellaneous items) of BOQ.
2 2 LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
3 2.01 Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 27 1 Each
4 2.02 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 28. 1 Each
5 2.03 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 29. 1 Each
6 2.04 Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-IV brought forward from serial page No. 31. 1 Each
7 2.05 Lump sum price worked out by the contractor for ROAD AND PATH WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 33. 1 Each
8 2.06 Lump sum price worked out by the contractor for AREA DRAINAGE WORKS listed in Schedule 'A' Part-VI brought forward from serial page No. 34. 1 Each
9 2.07 Lump sum price worked out by the contractor for SECURITY WALL & STEEL GATE WORKS listed in Schedule 'A' Part-VII brought forward from serial page No. 36. 1 Each
10 2.08 Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKS listed in Schedule 'A' Part-VIII brought forward from serial page No. 37. 1 Each
11 2.09 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 39 1 Each
12 2.1 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 40. 1 Each
13 2.11 Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORKS as listed in Schedule 'A' Part-XI brought forward from serial page No. 41. 1 Each
14 3 INTERNAL ELECTRIFICATION WORKS
15 3.01 Material and labour for concealed point wiring for one light point/fan point/bell point controlled by one switch complete with 1.5 sqmm (nominal cross sectional area) FRLS PVC insulated multi-stranded copper conductor in and including suitable size heavy duty non-metallic rigid PVC conduit (ISI marked) including fittings & accessories including MS concealed terminal boxes with 3mm thick plastic laminated bakelite (Hylum) sheet top cover for mounting switch socket etc including 1.5 sqmm FRLS PVC copper conductor multi-stranded as earth wire connected to the common earth dolly complete all as specified and directed. 91 Per point
16 3.02 All as per description of srl item No. 3.01 above but for one 3 pin socket outlet 5 Amp on same board. 10 Per point
17 3.03 All as per description of srl item No. 3.01 above but for one 3 pin socket outlet 5 Amp on independent board.\n 12 Per point
18 3.04 All as per description of srl item No. 3.01 above but for 3 pin, 15 Amps socket outlet with 2.5 sqmm copper conductor cable as main wiring & earth wire. 7 Per point
19 3.05 Supply and fix batten holder insulated body including LED lamp 10 W 220-240 volts, 6500K, B-22 base cap complete all as specified and directed. 20 Each
20 3.06 Supply and fix ceiling fan 1200mm sweep BEE star rated, AC 230 V, 50 c/s with double bearing copper wound, pressure die cast aluminium cover and aluminium blades, white coloured, with two years warranty including provision of cord flexible copper conductor 23/0.0076 three core from ceiling rose to connector complete all as specified and directed. 14 Each
21 3.07 Supply and fix exhaust fan 300mm sweep, AC, 230 Volts, heavy duty steel body with louvers complete with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan for giving connection complete all as specified and directed. \nNote: Cost of opening in wall and grouting of bolts shall be deemed included in the lump sum cost of the building. 4 Each
22 3.08 Supply and fix energy saving tube light luminaires with diffuser LED comprising of CRCA MS box and for fit 18 to 20 watt (max) retro fit tube rod having thermally conductive material heat sink, lumen output 2100 lumens (min) 6500K, power factor more than 0.95, IP 20 class-I protection with inbuilt LED driver surge protection device, operative on 140-270 volts AC supply complete pre-wired, connection and testing complete all as specified and directed. 48 Each
23 3.09 Supply and fixing for energy saving and environmental friendly long life versatile pressure die cast aluminium housing luminaire with heat resistant glass and suitable optics for uniform distribution of light 30 watt LED for bldg security light with high efficiency electronic driver, having IP-65 protection, surge protection device, power factor more than 0.9 complete operative on AC supply 140-270 volts pre wired and product should be made in India only complete all as specified and directed. 5 Each
24 3.1 Supply and fixing MCB, single pole 240 volts, capacity 6 - 32 Amps, C series 50 Hz, 10 KA complete all as specified and directed. 24 Each
25 3.11 Supply and fixing MCB, SPN 240 volts, capacity 32 Amps, C series 50 Hz, 10 KA complete all as specified and directed. 2 Each
26 3.12 Supply and fixing MCB, TPN 415 volts, capacity 63 Amps, C series 50 Hz, 10 KA complete all as specified and directed. 1 Each
27 3.13 Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth lead GI wire 4mm dia (8 SWG) connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 15mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete (1:3:6) type C-1 & RCC cover in M-20 (Design mix) reinforced with 8mm dia TMT bars @ 15cm c/c both ways and all as shown in Electrical Plate No 3 of MES standard Schedule of Rates (Part-I) of 2009 complete all as specified and directed.\nNotes :\n(i) Outer edge of earth pit shall be 1 m away from the outer edge of PCC chamber.\n(ii) GI earth wire form earth elctrode test point upto 7.5 metre is included in this item.\n(iii) Water pipe shall be provided in slanting position.\n(iv) Earthing work shall be carried out in the presence of Engineer-in-Charge or the rep detailed by him.\n(v) In case the desired test result of earthing not found satisfactory, contractor shall re-carry out the earth work at new location without any extra cost to the deptt. 2 Each Job
28 4 INTERNAL WATER SUPPLY WORKS
29 4.01 Supply and fix two way bib tap cast copper alloy with capstain head chromium plated fancy type with high pressure with or without lettered 'Hot' or 'Cold' with long shank and fly nuts screwed down, screwed for 15mm bore iron pipe or brass ferrule and fixed complete all as specified and directed. 11 Each
30 4.02 Supply and fix single lever basin mixer cast copper alloy chromium plated fancy type with crutch of butterfly handle with or without lettered 'Hot' or 'Cold' with long shank and fly nuts screwed down, screwed for 15mm bore iron pipe or brass ferrule and fixed complete all as specified and directed. 7 Each
31 4.03 Supply and fix angle valve cast copper alloy fancy type chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed complete all as specified 29 Each
32 4.04 Supply and fix health faucet (hand spray) chromium plated fancy type with 1 metre long PVC flexible pipe 15mm bore covered with chromium plated flexible tube connected to 15mm bore iron pipe incl holder for holding faucet fixed to wall with screws complete all as specified and directed. 11 Each
33 5 SEWAGE DISPOSAL WORKS
34 5.01 Supply and fix Cast Iron Manhole cover with frame heavy duty (HD) casting and confirming to IS: 1726:1991 for clear opening 560mmx560mm and chequer of cover shall not be less than 4mm . Manhole cover and frame coated with material having base with black bitumen composition. Frame shall be embedded in concrete firmly and complete all as specified and as directed. 12 Each
35 5.02 Supply and fix Cast Iron rung for Manhole of suitable dimensions confirming to IS:5455:1969 weighing 5.3 kg and footrest shall be painted with coal tar and portion embedded in cement concrete 1:2:4, type B-1 block 230mmx230mmx250mm complete all as specified and as directed. 39 Each
36 6 ROAD AND PATH WORKS\n
37 6.01 Material and labour for providing & making broken / continuous central / end line on the road pavement and the like of any description and width using thermoplastic paint with 8% glass beads by using special applicator machine with heating arrangement upto 1600C complete all as specified and directed. \nNote : The painted surface shall stand out boldly and solidly without showing signs of brush marks or surface under neath. If necessary, the surface shall be re-painted until the desired result is obtained. 27 Square Metre
38 7 RAIN WATER HARVESTING WORKS
39 7.01 Boring holes 200 mm dia in normal available strata upto 20 m depth by mechanical mehod including removal of surplus soil to a distance n. exc 50 metre complete all as specified and directed. 20 Running Metre
40 7.02 Supply and fix PVC pipe 160 mm outer dia class 'A' of pressure rating 6Kg/cm² including all necessary fitting complete all as specified and directed. 20 Running Metre
41 7.03 Supply and fix perforated/slotted PVC pipe 160 mm dia class 'A' including all necessary fittings complete all as specified and directed. 2 Running Metre
42 7.04 Material and labour for pea gravel packing including jute cloth as filter media 4mm to 6mm size around PVC pipe complete all as specified and directed. 3 Cubic Metre
43 7.05 Material and labour for filling pea gravel in RWH of size 6mm to 10mm complete all as specified and directed. 2.5 Cubic Metre
44 7.06 Material and labour for filling pea gravel in RWH of size 2mm to 4mm complete all as specified and directed. 2.5 Cubic Metre
45 8 EXTERNAL ELECTRIC SUPPLY WORKS
46 8.01 Supply, install, testing and commission distribution transformer with off load tap changer 100 KVA copper wound step down out door but placed on pole having voltage rating of 11000/ 433 volts 3 phase 4 wire naturally oil cooled IS :1180-2014 level-2 BIS mark connected delta on HV side to vary the secondary voltage ± 7.5% in the steps of ± 2.5% and star on LV side complete with standard accessories and oil filled upto the required level complete and testing after installation including following fittings & accessories complete all as specified and directed.\n(i) Name rating and diagram plate – 01 No\n(ii) Changing switch – 01 No\n(iii) Earthing terminals -2 Nos\n(iv) Lifting lugs- 02 Nos\n(v) Oil level indicator (flush tube) - 01 No\n( vi) Oil drain valve with plug – 01 No\n(vii) Oil filter valve with plug (on & above 100 KVA)- 01 No\n(viii) Conservation with oil filing hole- 01 No\n(ix) Thermometer pocket - 01 No\n(x) Dial type thermometer stem type-01 No\n(xi) Air release plug -01 No\n(xii) Silica gel breather -01 No\n(xiii) Explosion vent (if PRV Not opted) – 01 No\n(xiv) Arching horn set (only for HV bore bushing type transformer)\n 1 Each Job
47 8.02 Supply and fixing lightening arrester metal oxide type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11 KV, HT over head line complete including nuts, bolts, clamps, bracket etc and connecting with GI earth wire, complete all specified and directed 2 Set of three
48 8.03 Material & labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 32 x 6mm connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth strip connected to test point and protected by galvanized iron light grade 50mm bore and GI pipe 20mm bore light grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate and RCC cover in M-25 (Design mix) and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed.\nNotes :\n(i) Outer edge of earth pit shall be 1 m away from the outer edge of PCC chamber.\n(ii) GI earth strip for earth elctrode test point upto 7.5 metre is included in this item.\n(iii) Water pipe shall be provided in slanting position.\n(iv) Earthing shall be carried out in the presence of Engineer-in-Charge or the rep detailed by him.\n(v) In case the desired test result of earthing not found satisfactory, contractor shall re-carry out the earth work at new location without any extra cost to the deptt. 24 Each Job
49 8.04 Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth lead GI wire 4mm dia (8 SWG) connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 15mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete (1:3:6) type C-1 & RCC cover in M-20 (Design mix) and all as shown in Electrical Plate No 3 of MES standard Schedule of Rates (Part-I) of 2009 complete all as specified and directed.\nNotes :\n(i) Outer edge of earth pit will be 1m away from the outer edge of PCC chamber and the cost of additional earth lead, protection pipe shall be deemed included in unit quoted rate.\n(ii) GI earth wire form earth elctrode test point upto 7.5 metre is included in this item.\n(iii) Water pipe shall be provided in slanting position.\n(iv) Earthing shall be carried out in the presence of Engineer-in-Charge or the rep detailed by him.\n(v) In case the desired test result of earthing not found satisfactory, contractor shall re-carry out the earthing at new location without any extra cost to the deptt. 2 Each Job
50 8.05 Supply, installation, commissioning and testing of 40 KVAR automatic power factor correction (APFC) banks factory made cubical compartmentalized outdoor dust vermin and weather proof made out CRCA MS sheet of minimum 3.15mm thick of appropriate size of panel 0.9mX0.9mX0.45m, front openable, with locking arrangement supported on 50mm x 50mm x 6mm angle iron frame and 4 No legs 900mm long each, 50cm of each leg grouted in PCC (1:2:4) below floor level complete duly powder coated from inside and outside with seven tank process comprising of following :-\n(a) Copper bus bar of size 40mm x 5mm, 4 pole suitable for 300 Amp load capacity, duly colour coded with PVC sleeves -01 Job \n(b) MCCB 4 pole 160 Amp 50Hz, 415 V with adjustable thermal magnetic release and rupturing capacity 25KA - 01 No.\n(c) MCB ‘D’ series TP 32 Amp 10KA 415 volts -04 No.\n(d) MCB ‘D’ series TP 40 Amp 10KA -04 No.\n(e) Capacitive duty contractor (Heavy duty) cylindrical 10 KVAR -02 No.\n(e) Capacitive duty contractor (Heavy duty) cylindrical 5 KVAR -02 No. (e) Capacitive duty contractor (Heavy duty) cylindrical 3 KVAR -02 No. (e) Capacitive duty contractor (Heavy duty) cylindrical 2 KVAR -02 No.\n(j) Shunt capacitor (heavy duty cylindrical) 10 KVAR - 02 No. \n(k) Shunt capacitor (heavy duty cylindrical) 5 KVAR - 02 No. (k) Shunt capacitor (heavy duty cylindrical) 3 KVAR - 02 No. (k) Shunt capacitor (heavy duty cylindrical) 2 KVAR - 02 No.\n(m) Microprocessor based APFC relay 8 steps -01 No.\n(o) RYB Phase indicator LED type protection fuses -01 Set\n(p) Digital voltmeter 0-500 volts of size 96mm x 96mm with in-built selector switch duly pre-wired with suitable size copper wire -01 No\n(q) Digital Ammeter 0-500 Amps with inbuilt selector switch with CTs duly pre-wired with copper wire -01 No.\n\n 1 Each Job
51 8.06 Supply and fixing factory made Feeder panel box, outdoor type, vermin proof, made of powder coated CRCA MS sheet of 3.15mm thick, machine pressed, with 900mm long supports of angle iron 50mm x50mm x 6mm, 50cm of legs grouted in PCC 1:2:4 type B-1 below floor / ground, double door hinged type front and rear including locking arrangement, comparmentalised of suitable size, 415 volts AC 50 Hz, with 04 Nos aluminium bus bars of suitable capacity mounted on porcelain insulators and enclosed in chamber made of 3.15mm thick powder coated CRCA sheet, connections for incomimg and outgoung with necessary wiring, proper lugs / thimbles and comprising of the following :- \n(a) Incoming MCCB of current rating 160 Amp with thermal release 4 pole 415 volt, 35 KA rupturing capacity -01\n(b) Outgoing MCCB of current rating 100 Amp with thermal release 4 pole 415 volt, 16 KA rupturing capacity -01\n(c) Outgoing MCCB 63 Amp 4 Pole 415 Volt - 04 No.\n(d) Copper bus bar for 3 phase & neutral 200 Amp - 01 Set\n(e) Digital voltmeter (0-500 volts) 96mm x 96mm square type with inbuilt selector switch-01 No\n(f) Digital amps meter (0-200 Amps) square type with inbuilt selector switch and CTs-01 No\n(g) MCB 32 Amp SPN - 02 No.\n(h) Phase Indicator neon lamp RYB-01 Set of 3\n(j) Automatic phase sequence corrector with single phase preventor complete with all relays and contactor etc -01 No\n\n 1 Each Job
52 8.07 Supply and errection Hot dip galvanised Octagonal tubular pole (8.0 meter long) 60 mm at top and 130 mm at botton having 3 mm wall thickness with 12mm thick base plate of size 225mmx216mm along with 1 mtr long single arm, with 04 No. foundation bolt 16mm dia 650mm long, hot dip galvanised and anchor plate 6mm thick - 02 Nos complete all as specified and directed. \nNote:- Excavation, earth work and PCC shall be measured and paid for separately under appropriate items 25 Each
53 8.08 Supply and fixing LED type street light fitting, pressure die cast aluminium housing luminaries 90 watt LED, IP protection 66 including SPD, asymmetric type complete all as specified and directed. 25 Each
54 8.09 Supply and fixing cable route indicator on route of cable, with arrow made of CI of suitable shape showing "MES HT U/G Cable 11 KV / MES LT U/G Cable" (all words embosed) and fixed on 25mmx25mmx4mm angle iron not less than lenght 450 mm, fixed in position incl PCC 1:2:4 foundation of size 600mmx600mmx600mm complete all as specified and directed. 45 Each
55 8.1 Supply, installing, commissioning and testing eco-friendly diesel engine driven generating set silent type, canopy as per CPCB norms 24 KW/30 KVA, 0.8 power factor directly coupled alternator & engine, water cooled, common base platform with floor mounted fuel tank & including all excavation & earth work, PCC foundation, anti vibration pads / dampers, control panel and other accessories as per manufacturer’s design and comprising of the following :-\n(A) ENGINE :- Eco friendly for emission and noise (CPCB NORMS COMPLETE), diesel engine conforming to BS standard developing BHP as per standerd, @ 1500 RPM, turbo charged & cooled complete under NTP condition with a provision for 10% over load for one hour on 12 hours running with the following :- \n(i) Fly wheel with starter ring for generating set. (ii) Dry type air filter. (iii) Lube oil cooler assembly with accessories. (iv) Exhaust air manifold. (v) Exhaust silencer. (vi) Expansion bellow.\n(B) ALTERNATOR :- Single bearing alternator suitable for continuous operation generating 24 KW at 1500 RPM, 415 volts, 0.8 power factor sutable for 50 Hz, 3 phase, 4 wire system, . The alternator shall be brushless type screen protected revolving field, self regulated an AVR. The alternator has the following features :-\n(i) +1.0% voltage regulation (max) in static conditions. \n(ii) IP: 23 protection with insulation class 'H'. (iii) Permissible overload of 10% for one hour in 12 hours of operation.\n(C) ACCOUSTIC ENCLOSURE : (i) It shall be made of 1.6 mm CRCA sheets in and a structure steel base frame painted in black. (ii) The walls of the enclosure shall be insulated with fire retardant foam so as to comply with CPCB norms. (iii) Rest all as per manufacturing design and recommendations. (iv) Noise level not exceeding 75 DBA, at 1 meter away from the DG set.\n(D) FOLLOWING ITEMS: \n(i) 12 volts 88 AH DC battery dry type maintenance free with copper leads and terminal lugs of suitable size. (ii) One hand rotary type fuel pump connected with heavy duty pipe upto the tank. (iii) Adequate ventilation to meet air requirement for combustion and heat removal with provision of blower. (iv) Provision or light inside the canopy providing a FTL.\nNOTE: (i) Entire DG Set shall be procured from authorised dealer or original equipment Manufacturer. (ii) One fuel tank of gauge, inlet / outlet continuations, drain plug etc. mounted on suitable angle iron frame or grouted on wall as per manufacturer’s instructions. (iii) One set of AVM pads shall be fitted on base frame. \n\n\n\n\n 1 Each
56 9 EXTERNAL WATER SUPPLY WORKS
57 9.01 Material and labour for boring of new bore well with reverse rotory rig circulation method not less than 680mm bore dia through any kind of strata (soil/rocks) depth not exeeding 50metre from ground level including disposal of surplus soil to a distance not exceeding 100 metre, complete all as specified and directed 50 Per Metre Depth
58 9.02 All as per description of srl item No. 9.01 above but depth exceeding 50 metre and not exceeding 100 metre 50 Per Metre Depth
59 9.03 All as per description of srl item No. 9.01 above but depth exceeding 100 metre and not exceeding 150 metre 50 Per Metre Depth
60 9.04 All as per description of srl item No. 9.01 above but depth exceeding 150 metre and not exceeding 200 metre 50 Per Metre Depth
61 9.05 Supply, assembling, lowering and fixing into bore hole 350 mm bore MS housing/casing pipe heavy duty with wall thickness not less 8 mm, screwed and socketed, ISI marked (IS:4270) ERW in random length up to 6 metres, including and necessary fittings (such as special steel socket,coupling etc) duly painted with 2 coats of bituminous paint on external surfaces of pipe complete all as specified and directed. 75 Running Metre
62 9.06 All as per description of ser item No. 9.05 above but bore of pipe 250 mm 75 Running Metre
63 9.07 Material and labour for MS Strainer (filter) pipe 250 mm (10'') bore, 8 mm (minimum) wall thickness with screwed and socket ends in stranded length and welding and fixing support having slots 3/64'' to the size of sand grain complete including sockets coupling and jointing complete all as specified and directed. 50 Running Metre
64 9.08 Supply and fix 6 mm thick bail plug of mild steel, for 250 mm (10'') bore with strong iron hook,screwed and welded in casing pipe complete all as specified and directed \nNote : Length of pipe required to be fixed with bail plug shall be measured and paid for seperately 1 Each
65 9.09 Supply, fixing and lowering of MS centering guide into bore well,made out of flat MS rings.ribs suitable for 350 mm dia MS casing pipes as specified in IS code No. 2800 Part-I of 1991 complete all as specified & directed 6 Each
66 9.1 All as per ser item No. 9.09 above but suitable for 250 mm dia MS casing pipes 6 Each
67 9.11 Supply and fix MS reducer of size 350 x 250 mm, wall thickness 8 mm screwed at both ends including necessary fittings,fixing support and jointing at appropriate length complete all as specified, directed & shown in drg 1 Each
68 9.12 Supply and fix well cap for 350 mm bore pipe having internal and external threading with rings,ribs and welded iron handle suitable for casing pipe conforming to IS : 2800 Part-I of 1991 complete all as specified and directed. 1 Each
69 9.13 Supply and fix MS clamp made of flat iron 125mm x 12 mm, 1.5 metre long with nuts, bolts 22 mm dia of suitable length for holding housing pipe 350 mm bore embedded in PCC 1:3:6 Type C-1 complete all as specified and directed. 1 Each
70 9.14 Supply, lowering and packing pea gravel of size 1.5 mm to 4.5 mm (duly screened and washed) around the casing pipe and slotted pipes in bore hole complete all as specified & directed. Note : For the purpose of measurement,gravel brought by the contractor shall be stacked properly at site & measurement of stack shall be carried out before use & after use (left un-used) to arrive at the net qty of gravel used by the contractor in the work & the payment against this item shall only be made for the qty of gravel used in the work & not for the total qty of gravel brought at site. 60 Cubic Metre
71 9.15 Development of tube well bore by compressor of capacity not less than 1000 Cubic Metre/Hour and 600 PSI till sand free clear water is obtain and stabilization of the tube well complete all as specified and directed 36 Per Hour
72 9.16 Testing of tube well bore with heavy duty submersible pump of appropriate capacity but not less than 20000 GPH so as to obtain sand/silt free water upto 20 ppm in 20 minutes complete all as specified and directed Note : The discharge shall be measured by oriffice system or 'V' nitch fixed to steel tank of adequate capacity 15 Per Hour
73 9.17 Fabrication and supply of strata sample box, made out of 18 to 20 mm thick venered particle board and partition with 12 mm thick ply wood with 25x25x2 mm thick aluminiun angle bearer ,overall length 1200x750 mm with 20 partitions of size 150mmx100mmx100mm deep with front glass sheet 5 mm thick sliding type cover with suitable size 40mmx25mmx3 mm,aluminium handles & painting with 2 coats of synthetic enamel paint over a coat of pink primer after preparation of surfaces complete all as specified and drirected including writing name of tube well,location and strata sample with depth complete all as specified & directed. Note : Strata samples and strata chart shall be provided by contractor along with the strata sample box without any extra cost to the department. 1 Each
74 9.18 Testing of water for potability by chemical analysis such as pH value, dissolved solids, hardness as CaCO3, Calcium, Magnesium, Chlorides, Sulphates, Nitrate, alkalinity, iron, turbidity NTU, mineral oil, colour hazen units, taste, odour, residual free chlorine, total coliform per 100 ml (microbiological test) & E coil per 100 ml (microbiological test) as well as bacteriological portability from any Govt. Laboratory Govt accrediated Labortary and the report shall be submitted to the department complete all as specified & directed 1 Each Job
75 9.19 Supply only copies of assembly lowered alongwith borewell details on full scape size paper duly laminated and framed with 100 mm particle board complete all as specified & directed 5 Each Job
76 9.2 Material and labour for electric logging by means of electric logger of the complete tube well of 680 mm bore,submission of 4 copies of logging alongwith one original copy and its interpretation complete all as specified & directed 1 Each Job
77 9.21 Supply, installation, testing and commissioning of submersible pumping set of discharge capacity 1200 LPM at 100 metre head and not less than 25 HP suitable for a bore of 350 mm and including 3 phase,50 Hz,415 Volts electric motor of suitable capacity including MS adopter or reducer and all accessories etc for proper functioning of pumping set complete all as specified and directed. 2 Each Set
78 9.22 Supply, laying, jointing & testing submersible cable PVC insulated,multistranded,flat 3 core,10 Sq mm copper conductor suitable for working voltage 1100 volts including connections to motor / starter complete all as specified & directed. 200 Running Metre
79 9.23 Supply and fixing 100 mm bore GI heavy duty flange pipe 5.4 mm thick (Length not less than 3 Mtr each) with MS flange not less than 10 mm thick on both ends fixed by welding with special provisions such as MS supporting clamps slots for housing 02 Nos. submersible cable including nuts,bolts,washers and rubber gaskets etc complete all as specified and directed. 60 Running Metre
80 9.24 Supply, laying, jointing and testing in trenches 100mm bore ductile iron pipes with spigot and socketed ends class ‘K-7’ in any length all as per IS 8329/2000 with all necessary DI fitting including rubber gasket joints including testing all as specified and as directed.\nNote :- (i) Excavation, Earth work and DI fittings shall be measured and paid for separately under respective items.\n(ii) Cost of Rubber tyton joints is included in rate quoted\n(iii) Standard length of pipe shall be 5.50 metre or 6.0 metre as available\n(iv) The measurement of pipes shall be net as fixed between the fittings including short lengths without any allowance for cutting and wastage and for the portion entering in the sockets of pipes and fittings. 200 Running Metre
81 9.25 All as per dsecription of srl item No. 9.24 above but 150mm bore. 100 Running Metre
82 9.26 Matrial and labour for ductile iron fittings ISI marked for flanged or spigot socketed pipe such as tail piece, connecting pieces, bends tapers, tee pieces (single or double branch) any type and angle/radius and straight connecting pieces suitable for bore upto 150 mm pipe complete all as specified and directed.\nNote :- (i) Cost of rubber tyton joints is included in overall rate quoted\n(ii) Fittings shall be of same make as that of pipe or as recommended by manufacturer. 350 Kilogram
83 9.27 Supply and fixing air release valve with two air outlet kinetic design with isolating valve conforming to IS 14845 & ISI marked including all materials required for fixing/jointing all as specified all as directed for 150 mm dia 1 Each
84 9.28 Supply and fixing cast iron foot valve heavy duty of 150 mm including joint with jointing material complete all as specified and directed 2 Each
85 9.29 Supply & fixing Centrifugal Pumping set of capacity not less than 15 HP, dischage - 4.9 to 8.1LPS, head-40 to 50 mtr, RPM- 3000, AC 3 phase 400-440 volt 50 C/S complete all as specified and directed 2 Each
86 9.3 Material & labour brick masonry valve pit of size 90 cm x 90 cm x 90 cm (internal size) with cover of mild steel sheet 3 mm thick and angle iron frame of size 50mm x50mm x 6mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including locking arrtangement, brick work built in cement mortar 1:4 external surfaces in contact with earth pointed flush with same mortar as the work proceeds and all inner and exposed suraces of pit plastered in cement mortar 1:4 and painted with three coats of white wash, 100mm thick PCC base / foundation 1:4:8, type D-2, using 40mm graded crushed stone aggregate, PCC bed plate 100mm thick on top of wall complete all as specified and directed. 7 Each Job
87 9.31 All as per description of item No. 9.30 above but size of pit 60cm x 60cm x 60cm (internal size) 3 Each Job
88 9.32 Supply installng, testing and commissioning powder coated factory made, outdoor type panel board, conformimg to IP-55 protection, working for 440 volts, 3 phase, 50 Hz, AC of suitble size and construction made from 3.15mm thick GP sheet painted with 9 tank process, with countersunk holes at bottom for base mounting brackets sheet steel gland plates for cable entry, formed gasket around doors, pre-wired with suitable size PVC insulated copper conductor cables, multistranded, with provision of lock inserts, earthing strips, wiring plan pockets and grouted in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate), housed with the following :-\n\n(i) incoming MCCB 63 Amp, 35 KA, 4 Pole 415 Volt - 01 Nos\n(ii) out going MCB 40 Amp 4 pole 415 volt 10 KA - 03 Nos\n(iii) Copper bus bar for 3 Ph & Neutral 200 Amp- 01 Set\n(iv) Volt meter 0-500V \n(v) Ammeter with CTs 50 A and selector switch\n(vi) Phase indicator neon lamps RYB -01 Set of 03\n(vii) Fully automatic star delta starter suitable for 3 Phase submersible motor suitable for 25 HP capacity -01 Nos , for centrifugal pump suitable for -15 HP -02 including change over 160 Amp complete all as specified and as directed.\n 1 Each Job
89 10 WATER FILTRATION PLANT WORKS
90 10.01 Design, Supply, Installation, Testing and Commissioning of water Filtration cum recycle plant for Swimming Pool of size 50 M x 21 M x 2.0 M (Avg.depth) with diving facility at deep end with balancing tank of 200 m3, having total water capacity 23,00,000 litre suitable for 7 hrs turn over period , flow rate - 329 m3/hr complete with following: \n(a) Multi Grade Sand Filter- Vessel Dia -2400 mm , Vessel HOS -1875 mm, Filtration Flow Rate- 110 m³/Hr, Dishend Thickness -8mm, Shell Thickness -6mm , Made of Mild Steel, internal epoxy painted with collector arms and distributers made MS heavy duty pipe, frontal piping with 150 mm valve for filtration ,backwash & rinse process . working pressure 2.5 Kg/cm², desgn pressure - 3.5 kg/cm² , Test Pressure 5.0 Kg/cm². Filter to be supplied with main hole, handhole, pressure gauge, inclusive of Multi Grade sand media -Total 6500 kgs with media depth 915 mm confirming to IS-2062 Comprising of following :-. \nMake:- Ion Exchange/ Thermax or equivalent \n(i) Quartz Pebbles of 1" to 3/4" not less than 100 mm thick layer \n(ii) Quartz Pebbles of 3/4" to 1/2" not less than 100 mm thick layer \n(iii) Quartz Pebbles of 1/2" to 1/4" not less than 100 mm thick layer \n(iv) Quartz Pebbles of 1/4" to 1/10" not less than 100 mm thick layer\n(v) Quartz sand of assorted sizes not less than 900 mm thick layer \n(vi) Back wash arragement shall be made to facilitate the back washing system \n(vii) Pressure gauges -01 Lot as recommended by manufacturer of filter plant\n(viii) Air vent system with 25 mm pipe with gun metal valve\n(ix) Pressure relief valve ,nut and bolt and gasket for filter\n(x) Suitable size of main and hand hole. \n(xi) Filter Flow Rate: 110 M³/Hr\n(xii) Filtration Velocity: 25 M³/Hr/M² \n(xiii) Diameter: 2400 mm 3 Each Job
91 10.02 Supply, laying and jointing UPVC pressure Pipes 32mm dia Class 5 (10kg/cm2) with plain socket suitable for solvent cement jointing conforming to IS:4985-2000 & fittings conforming to IS:7834/87, Cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. complete all as specified and directed. The pipes & fittings shall be tested to a pressure of 10 Kg/Sq.cm\n 6 Running Metre
92 10.03 All as per description of serial item No. 10.02 above but dia of pipe 50mm 6 Running Metre
93 10.04 All as per description of serial item No. 10.02 above but dia of pipe 63mm 60 Running Metre
94 10.05 All as per description of serial item No. 10.02 above but dia of pipe 75mm 6 Running Metre
95 10.06 All as per description of serial item No. 10.02 above but dia of pipe 90mm 30 Running Metre
96 10.07 All as per description of serial item No. 10.02 above but dia of pipe 110mm 60 Running Metre
97 10.08 All as per description of serial item No. 10.02 above but dia of pipe 160mm 240 Running Metre
98 10.09 All as per description of serial item No. 10.02 above but dia of pipe 200mm 120 Running Metre
99 10.1 Supply and fixing CI butterfly valve 65mm bore tested to a pressure not less than 20 Kg/Sq.cm. Including rubber gasket, flanges, nuts, bolts, washers complete as required. -Lot 01 as per design requirement, as specified and directed.\n 20 Each
100 10.11 All as per description of serial item No. 10.10 above but dia of valve 80mm 1 Each
101 10.12 All as per description of serial item No. 10.10 above but dia of valve 100mm 12 Each
102 10.13 All as per description of serial item No. 10.10 above but dia of valve 150mm 6 Each
103 10.14 All as per description of serial item No. 10.10 above but dia of valve 200mm 5 Each
104 10.15 All as per description of serial item No. 10.10 above but dia of valve 350mm 1 Each
105 10.16 Supply and fixing CI dual plate Check Valve 65mm bore PN-20 complete with matching flanges, rubber insertion, nuts, bolts and washer etc. complete all as specified and directed. - Lot 01 as per design requirement 1 Each
106 10.17 All as per description of serial item No. 10.16 above but dia of valve 80mm 1 Each
107 10.18 All as per description of serial item No. 10.16 above but dia of valve 100mm 5 Each
108 10.19 All as per description of serial item No. 10.16 above but dia of valve 150mm 5 Each
109 10.2 All as per description of serial item No. 10.16 above but dia of valve 200mm 4 Each
110 10.21 Supply & fixing heavy duty PVC puddle flanges for 32mm dia UPVC pipe 10 kg/cm² fixed with flanges, (length 400 to 600 mm each) fixed on wall of plant room, balancing tank and the water body walls & Slab (As required). To be laid in between the steel reinforcement before RCC work. The cost of civil work shall not be deemed included in unit quoted rate of this item- Lot 01 as per design requirement \n 1 Each
111 10.22 All as per description of serial item No. 10.21 above but for dia of pipe 50mm 3 Each
112 10.23 All as per description of serial item No. 10.21 above but for dia of pipe 63mm 2 Each
113 10.24 All as per description of serial item No. 10.21 above but for dia of pipe 110mm 2 Each
114 10.25 All as per description of serial item No. 10.21 above but for dia of pipe 160mm 5 Each
115 10.26 All as per description of serial item No. 10.21 above but for dia of pipe 200mm 5 Each
116 10.27 Supply & fixing flow adjustable ABS Floor Inlet nozzle UV treated with stainless steel screws to fit in 2" PVC pipe, Flow Rate- 5 cum/Hr complete all as specified and directed. 90 Each
117 10.28 Supply & fixing of ABS white plastic suction port / Vacuum nozzle with 2'' solvent cement connection complete all as specified and directed. 10 Each
118 10.29 Supply, Installation, Testing and Commissioning of Self Priming centrifugal pump CI body, with pot type strainer basket with matching connection size and vibration eliminating rubber bellows, CI/Bronze Impellers, Carbon steel Motor shaft with Mechanical seal with Graphite/Ceramic, motor -2800rpm, F class insulation, protection IP-55 (3W+1S), AC, 3 Phase, 415 volt complete all as specified and directed.\n(i) Discharge/ Flow Rate: 110 M³/Hr. (Minimum)\n(ii) Head : to suit the flow of filter plant or as recommended by filteration plant manufacturer- not less than 25 Mtr, not less than 15HP. \n 4 Each
119 10.3 Design, Supply, Installation, Testing and Commissioning of Ionizer system suitable for 165 m3/Hr, comprising of electronic control panel to generate low power DC supply for electrode of copper and Silver, timing device to change polarity after every 6 to10 minutes, with following specifications:- \n(a) SS BODY - silver+ copper electrodes in each chamber\n(b) Silver / Copper electrodes in each chamber \n(c) Control panel and control unit with voltage and LED display meters. \n(d) Automatic polarity reversal serve with indication cables up to 3 Meters to connect with chambers.\n(e) Inlet /out let Header line for Ionizer – common header lines with common header line for inlet & Outlet .\n(f) Maximum pressure – 2.5- 3.0 Kg/sqcm with piping, header line, flange, bolting 2 Each Set
120 10.31 Supply, install, automatic chlorine dozer having FRP type tank of capacity of 200 ltrs and frame work with 35mmx35mmx5mm angle iron in rectangular design and FRP lined using Isopthalic resin on both sides i.e. inside & outside and fitted with electronic diphragm pumps with capacity of 6 LPH flow rate at an injection pressure 5 Kg/sqcm, the tank fitted with glass tubes, level indicators as per manufacturer's design complete all as specified and directed.\ni) Capacity 0-26 litres/hr. \n(ii) Head 35 M\n 3 Each
121 10.32 Supply only suction sweeper kit, Trolley mounted, with suction SP Series pump motor capacity not less than 2 HP, 3 phase, AC, 50Hz, Head range -9-23m, discharge range-6.2 LPS, 900mm long Trolly made of MS frame, painted with synthetic enamel paint, with rubber wheels for smooth movement arround the deck complete with motor, pump & starter, alongwith with heavy duty nylon brush size 50mm x 900mm, and float to support the hose, clips for connection - 10 Nos, complete all as specified and directed 2 Each
122 10.33 Supply, installation, testing and commissioning of header system of dia 350mm suitable for pumping sets and filtration plant listed in item No. 10.01 here in before, MS "C" class Epoxy Coated Suction and Delivery Header including cutting, welding and making provision for different pipe connections e.g. Balancing tank suction line, pump suction, drain connection incl foot valve, inlet connection with all necessery fittings, flanges, Nuts bolts, gaskets as required to complete the job as per recommendations of filtration plant/pump set's manufacturer 1 Each Job
123 10.34 Supply, installation, testing and commissioning of GI perforated Cable Tray 150 mm wide all as specified and directed 40 Running Metre
124 10.35 Supply, installation, testing and commissioning of GI perforated Cable Tray 200 mm wide all as specified and directed 20 Running Metre
125 10.36 Supply, installation, testing and commissioning of GI perforated Cable Tray 300 mm wide all as specified and directed 50 Running Metre
126 10.37 Material and labour for MS Structure work conforming to Fe-290 Grade E-165, with MS Angle, Fastners, Tie Rods, for supporting pipe and pump footing including cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up including applying two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces and only a coat of red oxide primer on un-exposed surfaces and fixing complete all as specified and directed\n 700 Kilogram
127 10.38 Supply and fixing anodised extruded stainless steel vacuum head 900mm size, fixed with dip type connector 1½" maintenance kit complete all as specified and directed 2 Each
128 10.39 Supply only reinforced telescopic Handle 3.6-7.2 mtr long all as specified and directed 2 Each
129 10.4 Supply only floating suction, made of polyethyene blue colour, size 40 mm (1-1/2") 30 metre long all as specified and directed 2 Each
130 10.41 Supply only deep Bag skimmer clip type all as specified and directed 2 Each
131 10.42 Supply only water surface skimmer clip type all as specified and directed 2 Each
132 10.43 Supply only curved brush clip type all as specified and directed 2 Each
133 10.44 Supply only test kit for pH and chlorine all as specified and directed 2 Each
134 10.45 Supply only Algae Brush SS Bristal all as specified and directed 2 Each
135 10.46 Supply only staright brush clip all as specified and directed 2 Each
136 10.47 Supply only of calcium based high strength chlorinator for water disinfectant as granular in factory sealed HDPE container (45 to 50 kg each) having chlorine concentration level not less than 65% complete all as specified and as directed. Make : Aquafit / Declibac Technologies Pvt Ltd or equivalent 350 Kilogram
137 10.48 Supply only Trichloroisocyanuric acid TCCA-90 (swimming pool treatment compound) in granular from having concentration 90% in factory sealed HDPE container of 45 to 50 kg each. Make : Eureka Forbes Pvt Ttd / Aditya Birla or equivalent 350 Kilogram
138 10.49 supply and fixing nylon brush (soft quality) with wooden base of size 3 feet long, 2.5 Inch wide locally available best quality, suitable for fixing to suction sweeper complete all as specified and directed. 2 Each
139 10.5 Supply, installation, testing and commissioning motor control panel of 415 V, 3 Phase and 50 Hz capacity, switchboard cubical indoor type made of 16 SWG CRCA Sheet duly powder coated with 7 tank process grey shade. The cubical is wall mounted with dust & vermin Proof construction with inter connection, comprising of the following:-\n(i) Incoming mains of 160 Amps, 36 kA, 50 Hz . MCCB – FP, 01 No. \n(ii) Outgoing mains of 63 Amps 25 kA, 50 Hz . MCCB – FP, .- for each starter \n(ii) 0 – 600 V Digital Voltmeter, 96 Sq.mm with voltage selector switch.- 1 No.\n(iii) 3 phase LED type indicating lights for incoming mains - 01 set \n(iv) 0 – 60/5 A Digital Ammeter, CT operated, 96 Sq.mm with ampere meter selector switch- 5 No.\n(v) Automatic STAR Delta starter with ON/OFF push button and ON/OFF indication light- 5+1 set .suitable for 15/20 HP pump motor \n(vi) Auto/Manual selector switches- 1 No.\n(v) Single phase preventor- for each starter\n(vi) MCB DP 20 Amps- 2 nos. \n(vii) MCB DP 20 Amps for Ionizer -3 nos. \n(viii) MCB SP 6 Amps. For Dozer- 3 nos. 1 Each Job
140 10.51 Supply and fixing nylon rope of size 20mm / 25mm dia multi stranded super flexible type all as specified and directed. 50 Kilogram
141 10.52 Supply and fixing PVC insulated copper cable with cross sectional area 6 sqmm, 3 core complete all as specified and directed. 200 Running Metre
142 10.53 Supply only Alum crystal free from impurity, class-I suitable for swimming pools complete all as specified and directed. 200 Kilogram
143 10.54 Supply only Copper sulphate of superior quality complete all as specified and directed. 150 Kilogram
144 10.55 Supply only "O" Todoline solution for water testing purpose in 500 ml bottle complete all as specified and directed. Make : Nice/Glaxo or equivalent 4 Each
Disclaimer :