Public Works Department-PWD has published Eor To Co Of Toilet Block Septic Tank Parking Shed Renovation Of Principal Room Gbsss Katewara Repair And Renovation Toilet Block At Gsbv Prahaladpur Banger C Pf Wall Tiles False Ceiling M . S . Gate Ralling Flush Door And Misc . Wo. Submission Date for this Tender is 05-12-2020. Shed Construction Tenders in as per nit Delhi. Bidders can get complete Tender details and download the document.
Name of Work:(A) EOR to C/o of toilet block, septic tank, parking shed, renovation of Principal Room GBSSS Katewara. (B) Repair and renovation toilet block at GSBV, Prahaladpur Banger, (C) P/F wall tiles, false ceiling, M.S. Gate, ralling, flush door and misc. Work at RSGSKV, Bawana, Delhi. (SH:- Electrical Works.) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.\nGroup C | 1 | 64 | Point |
2 | 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.\nGroup C | 2 | 206 | Point |
3 | 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.\n3 x 1.5 sq. Mm | 3 | 900 | meter |
4 | 3.01 | 6 x 1.5 sq. Mm | 4 | 100 | meter |
5 | 3.02 | 3 x 4 sq. Mm | 5 | 100 | meter |
6 | 3.03 | 6 x 4 sq. Mm | 6 | 75 | meter |
7 | 4 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required\n20 mm | 7 | 150 | meter |
8 | 4.01 | 25 mm | 8 | 400 | meter |
9 | 5 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.\n5/6 A switch | 9 | 1080 | Each |
10 | 6 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.\n4 Module (125 mmX75 mm) | 10 | 2 | Each |
11 | 6.01 | 12 Module (200 mmX150 mm) | 11 | 93 | Each |
12 | 7 | Supplying, Installation, testing and commissioning of pre-wired, Indoor decorative LED batten with extruded aluminium housing & opal diffuser. IP20 of following types suitable for cool day-light having CCT (5600K to 6500K), power factor >0.90, CRI > 75 & minimum Lumens output should be > 90 lumens per watt. including dismantling the old fitting complete with all accessories etc. directly on ceiling / wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.\n34 to 36 watts1x4 feet LED batten. | 12 | 40 | each |
13 | 8 | Supplying, Installation, testing and commissioning of following type pre-wired, aluminium body LED panel luminaire having 100 Lumen per watt, CCT (5700K to 6500K), power factor >0.90, CRI > 70% & complete with all accessories etc. including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.\n36-42 watts 2' x 2' LED light luminaires suitable for recessed armstrong/grid ceiling. | 13 | 30 | each |
14 | 9 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required | 14 | 10 | each |
15 | 10 | Supplying and Installation of heavy duty exhaust fan alongwith aluminium louvers of 300 mm sweep 900 rpm in the existing opening, including making the hole suitable the size of the above fan making good the damage, connection testing commissioning etc as reqd. | 15 | 7 | each |
16 | 11 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 16 | 13 | Each |
17 | 12 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. | 17 | 4 | set |
18 | 13 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. | 18 | 20 | Mtr. |
19 | 14 | Providing and fixing G.I. strip 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required | 19 | 40 | Mtr. |
20 | 15 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required\n63 mm dia (OD-63 mm & ID-51 mm nominal) | 20 | 150 | Mtrs. |
21 | 16 | Supplying & Laying of one number XLPE insulated and PVC sheathed aluminium conductor, armoured underground power cable of 1.1 KV grade of following size etc as required.\n4 X 16 sq.mm(in pipe) | 21 | 150 | Mtr. |
22 | 17 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 22 | 300 | Mtr. |