Public Works Department-PWD has published Rmo Street Lights Pumps And Ei Of Various Under Passes , Rub Ways , Subways And Underneath Of Flyovers Under Pwd M253 Delhi Sachivalaya , New Delhi During 2020-2021 . Sh Providing Accessories To High Mast Power Cables On Pwd Roads Under Emd M253. Submission Date for this Tender is 08-12-2020. Electrical Maintenance Tenders in Delhi Sachivalaya Delhi. Bidders can get complete Tender details and download the document.
Name of Work:-RMO Street lights, Pumps and E.I of various under passes, RUB ways, Subways and underneath of Flyovers under PWD M-253, Delhi Sachivalaya, New Delhi during 2020-2021. SH: Providing accessories to High Mast, Power cables on PWD Roads under EMD M253 | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.\na) Hot finished welded type tubes | 120 | Kg | |
2 | 2 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.\na) 100 Amp, 16 KA, TPMCCB | 20 | Each | |
3 | 2.1 | b) 200 Amp, 16 KA, TPMCCB | 5 | Each | |
4 | 3 | Supplying and testing of following size one number XLPE insulated aluminium phase and neutral conductor and bare messenger conductor Aerial Bunched power cable of 1.1 kV grade conforming to IS 14255: 1995 as required.\na) 4C x 16 sq. mm + 25 sq. mm | 3000 | Metre | |
5 | 3.1 | b) 4C x 25 sq. mm + 25 sq. mm | 7000 | Metre | |
6 | 4 | Laying of one number XLPE insulated aluminium conductor Aerial Bunched power cable of 1.1 kV grade of following size on poles up to 16 m height using the existing support including tower wagon or special T&P etc. complete as required.\na) Upto 35 sq. mm | 10000 | Metre | |
7 | 5 | Supplying, fixing, testing and commissioning of following size aluminium tapping (piercing) connector in the existing Aerial Bunched power cable of 1.1 kV grade by removing the insulated materials from the cable making connection with the tapping cable using tower wagon etc. complete as required.\na) 16 to 70 sq. mm | 350 | Each | |
8 | 6 | Supplying of following accessories for laying of existing Aerial Bunched power cable of 1.1 kV grade on existing pole/pillar etc. complete as required.\na) Dead End clamp | 10 | Each | |
9 | 6.1 | b) Suspension clamp | 400 | Each | |
10 | 6.2 | c) I-Hook | 400 | Each | |
11 | 7 | Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.\na) 63 amps TP MCB | 8 | Each | |
12 | 8 | Supplying, installation, testing & commissioning of the following accessories on the existing high mast suitable for fixing luminaires complete with wiring the fittings complete i/c dismantling the high mast complete with the help of hydra, crane and heavy duty machine from foundation and re-erected the same on existing shallow foundation with the help of chain pulley, hydra/crane and tower wagon duly assembling the ring, head frame, lantern carriage and connecting with the help of ERP rubberised trailing copper conductor cable i/c connections, testing, commissioning etc. i/c complete with greasing the pinions, making required holes to fix the same etc. as reqd.\na) Double Drum Winch, integral power tool, 6C x 4 sq.mm trailing cable, hardware ,connectors, manual handle ,junction box, SS Wire rope 7 x 7 on existing high mast complete with U clamp of both the ends complete with nut bolt etc. for 30 m High Mast. | 8 | Set | |
13 | 8.1 | b) Lantern Carriage in two sections suitable for mounting 12 Nos. of LED Fixtures and 3C x 2.5 sq.mm flexible copper conductor wiring from looping box for 30 m High Mast | 8 | Set | |
14 | 8.2 | c) Winch mounting bracket, suitable head frame for mounting on top of 30 m High mast | 8 | Set | |
15 | 8.3 | d) Double Drum Winch, integral power tool, 6C x 4 sq.mm trailing cable, hardware ,connectors, manual handle ,junction box, SS Wire rope 7 x 7 on existing high mast complete with U clamp of both the ends complete with nut bolt etc. for 20 m High Mast | 3 | Set | |
16 | 8.4 | e) Lantern Carriage in two sections suitable for mounting 9 Nos. of LED Fixtures and 3C x 2.5 sq.mm flexible copper conductor wiring from looping box for 20 m High Mast | 3 | Set | |
17 | 8.5 | f) Winch mounting bracket, suitable head frame for mounting on top of 16/20 m High mast. | 7 | Set | |
18 | 8.6 | g) Double Drum Winch, integral power tool, 6C x 4 sq.mm trailing cable, hardware, connectors, manual handle ,junction box, SS Wire rope 7 x 7 on existing high mast complete with U clamp of both the ends complete with nut bolt etc. for 16 m High Mast. | 4 | Set | |
19 | 8.7 | h) Lantern Carriage in two sections suitable for mounting 8 Nos. of LED Fixtures and 3C x 2.5 sq.mm flexible copper conductor wiring from looping box for 16 m High Mast | 4 | Set | |
20 | 9 | Supplying, installing, testing and commissioning of following outdoor, IP 54 protected, post top LED Luminaire with spun aluminium top cover, non-yellowing translucent UV stabilised acrylic diffuser, die cast aluminium spigot base, integral power supply for LED, 4 kV Surge protection, suitable for 230 VAC, 1 Phase, 50 Hz power supply on existing Pole i/c wiring with 3C x 1.5 sq.mm PVC insulated PVC Round Sheathed copper conductor flexible cable from Looping box to fitting, making connections etc. complete as required.\na) Minimum 4000 Lumens &100 lm/W efficacy | 15 | Each | |
21 | 10 | Supplying and fixing of following RoHS and EMC compliant LED flood light with high pressure die cast aluminium housing, IP66 ingress protection, tempered glass/UV Resistant Poly Carbonate cover, individual lense over LED for glare control, 10kV surge protection, narrow/wide beam optics as per requirement etc with following specifications.\na) Min. Lumens output: 30000\nMinimum system lumen efficacy: 120 lm/W\nTHD: <20%, PF: >0.90, CRI: 70\nColour Temperature: 5700K/6500K\nL70B50 = 50,000Hrs | 155 | Each | |
22 | 11 | Supplying and fixing of following ways surface / recess mounting, vertical type, IP 43 ingress protected, 36 kA for 1 sec short time withstand current, type tested, 415 VAC, 50 Hz, 3-phase 4 wire with earthing system, MCCB sub main distribution board compliance with latest standard IEC 61439-2, suitable for FP MCCB incomer and TP MCCB outgoing of totally enclosed sheet steel, dust protected, duly powder painted, inclusive of 250 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCCBs (but without MCCBs) as required.\na) 4 way, Double door | 5 | Each | |
23 | 12 | Supplying and fixing of prewired metering Box for following rated Sub main MCCB Distribution Board on top of the existing DB in surface / recess mounting, IP 43 ingress protected, 415 VAC, 50 Hz, 3-phase 4 wire with earthing system, Space and opening Provision for 3 Nos. single phase Ammeter (96 mm x 96 mm), 1 No. single phase Voltmeter (96 mm x 96 mm) with selector switch, 3 Nos. LED Phase indication lamps etc. as required.\na) Up to 400 A | 5 | Each | |
24 | 13 | Supplying, installation, testing & commissioning of following switch gears, starters, metering devices in the existing LT Panel including making connection with the existing bus bar, electrical connection etc. complete as required.\na) Digital LED 1 phase Volt Meter with Class I accuracy | 5 | Set | |
25 | 13.1 | b) Digital LED 1 phase ammeter with Class I accuracy | 15 | Set | |
26 | 13.2 | c) Selector Switch for voltmeter | 5 | Set | |
27 | 13.3 | d) Current Transformer up to 500 A/5 A | 15 | Each |