Military Engineer Services-MES has published Repair And Maintenance Of Sewage Pump , Swimming Pool , Incinerator , Fire Alarm System , Lift And Diesel Gen Set At Tibri Mil Stn Under Ge Gurdaspur .. Submission Date for this Tender is 23-12-2020. Fire Alarm Systems Tenders in Garrison Engineer, Gurdaspur (Tibri) Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

26105520
Corrigendum : Repair And Maintenance Of Sewage Pump , Swimming Pool , Incinerator , Fire Alarm System , Lift And Diesel Gen Set At Tibri Mil Stn Under Ge Gurdaspur .
Open Tender
Indian
Punjab
Garrison Engineer, Gurdaspur (Tibri)
23-12-2020

Tender Details

repair and Maintenance of sewage pump , swimming pool , incinerator , fire alarm system , lift and diesel gen set at tibri mil stn under ge gurdaspur .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Dec-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-12-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair and maint of sewage pump, swimming pool, incinerators, fire alarm system, lift and diesel Gen Set at Tibri Mil Stn under GE Gurdaspur.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 BOQ
2 2 Repair to alternater 110 KVA /100 KVA disconnecting electrical connection from site carefully and shifting to repair workshop dismantling the complete alternator and dismentling stator winding carefully and rewinding of stator with super enamelled existing size of copper winding wire with insulation material and varnish. Reassembling after repair and shifting to site and testing on load with full satisfaction of Engineer-in-Charge.\nNote : All T&P, Vehicle and labour shall be provided by contractor. 1 Job
3 3 Supply and replacement of self starter Assbly 12 volt complete with battery lead and battery terminal suitable for 100 to 125 KVA DG Set all as directed. Make :- Lucas or as equivalent all as specified and directed. 1 Nos
4 4 Repair overhauling of self starter 12 Volts including replacement of worn out clutch, repair to main AUX field coil, solonoid switch, corbon brushs, spring and rewinding of armature etc for 25 KVA to 63 KVA DG set. Make Lucas 5 Each\n
5 5 All as per Srl item No 3 above here-in-before but for 100 KVA to 125 KVA DG Set. 4 Each\n
6 6 M&L for repair /overhauling of dynomo including supply & replacement of new carbun brush and re-winding of armature and testing on load of the DG set of capacity 100 KVA all as directed by Engineer in Charge. 1 Job
7 7 Taking out existing non clog sewage pump, set of any type and size from sewage sump (alongwith existing column pipe) including all fittings complete all as specified and directed.\nNote : All T & P vehicle and man power shall be provided by contractor. 6 Each\n
8 8 M&L for lowering non clog sewage pump, set of any type and size in sewage sump (alongwith column pipe) including all fittings complete all as specified and directed.\nNote : All T & P vehicle and man power shall be provided by contractor. 6 Each\n
9 9 M&L for disconnecting and taking out motor from non clog sewage pump, dismantaling the burnt motor, rewinding the motor with super enamelled copper winding wire as per existing gauge, size including suitable insulation material cotton tape, varnish , insulation paper , sleeves and dry & baking etc connections etc and assembling complete after duly repair installation, commisioning and testing upto the satisfactory working performance including replacing bearing for NDE & DE side of motors for the capacitiy 12.5 HP, 3 Phase, 415 Volt, complete all as specified and directed. \nNote:- All T&P vehicle and manpower will be provided by contractor. The repair of pump motor should be carried out within 72 hours after intimation of breakdown to the contractor by means of whats up, massage, phone calls, letter etc. Contractor should carry out testing for smooth functioning of pump motor at existing position within 72 hours failing which a penalty of Rs. 2000/- per days will be levived on the contractor. 6 Each \nJob
10 10 S&F in replacement of Impeller CI sutaible for 12.5 HP sewage non clog pumping set complete all as specified. 6 Each\n
11 11 S&F in replacement of Ball Bearing as per sample for 12.5 HP sewage non clog pumping set etc complete all as specified. 6 Each\n
12 12 S&F MS tail piece, 6" dia, length as required, both end flanged, with nuts bolt and rubber flanged complete in replacement of existing unserviceable tail piece all as specified and directed. 100 Kg
13 13 S&F rubber insertion sheet/ gasket sheet 4 mm thick for flanged MS/CI/DI pipe in replacement of old damaged rubber gasket sheet all as specified and directed. 100 Kg
14 14 Taking out, dismantaling the mono block pump motor, from foundation / site, transporting the same to workshop, taking out of all burnt winding wires by strip opening of 3phase electric motor of any make, rewinding the motor with super enamled copper winding wire of required gauge and quantity including varnishing insulation sheet cotton, glass sleave etc as required, reassembling,testing, transporting back to site from workshop, installing back and making connection and again testing for motor capacity 1 HP to 2 HP complete all as specified and directed 1 Each
15 15 All as per Srl item No 14 here-in-before but for motor of capacity 3HP to 4HP 1 Each\n
16 16 All as per Srl item No 14 here-in-before but for motor of capacity 5HP to 7.5HP 1 Each
17 17 All as per Srl item No 14 here-in-before but for motor of capacity 12.5 HP. 1 Each
18 18 Supply & fixing Mechanical Oil Seal for 12.5 HP, sewerge submersible motor & pump including taking down old unserviceable one all as specified and directed. Make : Kirloskar or equivalent approved. 6 Each
19 19 M & L battery lead acid type 180 AH, 12 Volts 25 plates, maintenance free complate all as specified and directed. Make :- Exide/Amco/Amaron/Standard. 4 Each
20 20 M & L battery lead acid type 120 AH, 12 Volts 25 plates, maintenance free complate all as specified and directed. Make :-Exide/Amco/Amaron/Standard. 5 Each
21 21 M & L battery lead acid type 100 AH, 12 Volts 25 plates, maintenance free complate all as specified and directed. Make:- Exide/Amco/Amaron/Standard. 6 Each
22 22 M & L in replacement of PVC insulated battery lead stranded copper conductor of size 50 Sq mm suitable complete all as specified & directed . 20 RM
23 23 General servicing of DG Set of 12.5 KVA capacity, Make kirloskar, Model D-9, Air cooled type by cleaning externally, taking out tapet cover and carrying out tappet setting including replacement of tappet cover gasket, tightening of all external fasteners, bolts, nuts etc., cleaning of benjo bolt filter of fuel feed pump, cleaning of fuel filters, oil filters and air filter including replacement of filter elements, engine oil, fan belts, engine hoses, worn out electric wiring, meters, including toping up of coolant, electrolyte of battery etc. all as required and directed for proper designed output of gen set.\nNOTE: Spares e.g. fuel filter element, oil filter element, air filter element, coolant, hose pipes, fan belts, meters etc. as required to be replaced shall be measured and paid seprately as "material only". Minor parts e.g. bolts, nuts, washers etc. including necessary T & P and cleaning materials as required for servicing shall deemed to be included in the rate quoted. 1 Each
24 24 All as per Srl item No 23 here-in-before but for DG set of capacity 25 KVA to 30 KVA Make :- Cromton Greaves / Kirloskar, water cooled type. 1 Each
25 25 All as per Srl item No 23 here-in-before but for DG set of capacity 35 KVA 100 KVA , Make :- Cromton Greaves / Kirloskar, water cooled type. 1 Each
26 26 All as per Srl item No 23 here-in-before but for DG set of capacity 110 KVA to 125 KVA, Make :- Kirloskar, water cooled type. 1 Each
27 27 Material only pre filter and fine diesel filter element for 12.5 KVA Gen Set. Make :- Kirloskar 1 Set
28 28 All as per Srl item No 27 here-in-before but for 25 KVA Gen Set. Make :- Cromton Greaves / Kirloskar, water cooled type. 1 Set
29 29 All as per Srl item No 27 here-in-before but for 30 KVA to 35 KVA Gen Set. Make :- Kirloskar, water cooled type. 2 Set
30 30 All as per Srl item No 27 here-in-before but for 40 KVAto 63 KVA Gen Set. Make :- Kirloskar, water cooled type. 2 Set
31 31 All as per Srl item No 27 here-in-before but for 100 KVA to 125 KVA Gen Set. Make:- Jackson / Cummins and Kirloskar, water cooled type. 3 Set
32 32 Material only oil filter element for 12.5 KVA Gen Set. Make :-Kirloskar 1 Each
33 33 All as per Srl item No 32 here-in-before but for 25 KVA to 35 KVA Gen Set, Make :- Cromton Greaves / Kirloskar, water cooled type. 2 Each\n
34 34 All as per Srl item No 32 here-in-before but for 40 KVA to 63 KVA Gen Set, Make :- Kirloskar, water cooled type. 2 Each
35 35 All as per Srl item No 32 here-in-before but for 100 KVA to 125 KVA Gen Set, Make:- Jackson / Cummins and Kirloskar, water cooled type. 3 Each
36 36 S&F rubber coupling for 12.5KVA Gen Set, Make:- Kirloskar 1 Each
37 37 All as per Srl item No 36 here-in-before but for 25 KVA to 35 KVA Gen Set, Make Cromton Greaves / Kirloskar, water cooled type. 2 Each
38 38 All as per Srl item No 36 here-in-before but for 40 KVA to 63 KVA Gen Set, Make Kirloskar, water cooled type. 3 Each
39 39 All as per Srl item No 36 here-in-before but for 100 KVA to 125 KVA Gen Set, Make Jackson / Cummins and Kirloskar, water cooled type. 3 Each
40 40 S&F fan belt for 12.5KVA Gen Set of existing size, Make :-Kirloskar/ Fenner or equivalent 1 Each
41 41 All as per Srl item No 40 here-in-before but for 25 KVA to 35 KVA Gen Set, Make Cromton Greaves / Kirloskar, water cooled type. 2 Each
42 42 All as per Srl item No 40 here-in-before but for 40 KVA to 63 KVA Gen Set, Make Kirloskar, water cooled type. 3 Each\n
43 43 All as per Srl item No 40 here-in-before but for 100 KVA to 125 KVA Gen Set, Make Jackson / Cummins and Kirloskar, water cooled type. 3 Each\n
44 44 Supply and fixing of Hose Pipe Set with clamp for DG Set of 25 KVA to 35 KVA. Make :- Kirloskar 2 Each
45 45 All as per Srl item No 44 here-in-before but for 40 KVA to 63 KVA Gen Set, Make Kirloskar, water cooled type. 2 Each
46 46 All as per Srl item No 44 here-in-before but for 100 KVA to 125 KVA Gen Set, Make Jackson / Cummins and Kirloskar, water cooled type. 2 Each
47 47 Overhauling and calibration of FIP assembly of 12.5 KVA capacity DG Set at an authorised workshop including replacement of worn out rings, plungers, damper plates, gasket etc.and including taking out, transporting, refitting, refixing & testing complete. Make :- Mico 1 Each
48 48 Overhauling and calibration of FIP assembly of 25 KVA to 63 KVA capacity DG Set at an authorised workshop including replacement of worn out rings, plungers, damper plates, gasket etc.and including taking out, transporting, refitting, refixing & testing complete. Make :- Mico 5 Each
49 49 Material only for topping up of water coolent in radiator of DG set TVS Girling/volvo line or of equivelent make all as directed by Engineer-in-Charge. Make Castrol, Servo, Max 300 Ltr
50 50 S & F of engine oil of DG Set of 10W-30/20W40 or equivalent of Make : Castrol/volvoline all as directed by Engineer-In-charge 300 Ltr
51 51 M&L for replacement of rectifire for the DG set of capacity 12.5 KVA to 63 KVA all as specified and directed by Engineer-in-Charge. 2 Job
52 52 M&L for replacement of rectifire for the DG set of capacity 100 KVA to 125 KVA all as specified and directed by Engineer-in-Charge. 1 Job
53 53 S&F automatic voltage regulator suitable for DG Set for 25 KVA to 125 KVA. Make :- Kirloskar. 6 Each
54 54 Taking out the radiator assembly of DG set of 125 KVA capacity and transporting to work shop dismantling upper and lower tank and cleaning thoroughly, replacement of gasket packing , nuts, bolts, washers, descaling with appropriate chemical and brazing of damazed fins / tubes and reassembling & refixing in same position after testing complete all as specified and directed. 2 Each
55 55 All as per srl item No 54 here-in-before but for DG Set of capacity 100 KVA to 63 KVA 3 Each
56 56 All as per Srl item No 54 here-in-before but for DG Set of capacity 30/40 KVA 2 Each\n
57 57 M & L for replacement of battery terminals brass with steel nuts, bolts & washers complete all as specified and directed. 30 Each\n
58 58 S & F of on load change over switches 100amp, TPN, 415 Volts with sheet steel enclosure. Make : ABB/C&S/HPL/Havells/Indo Asian. 2 Each
59 59 All as per Srl item No 58 here-in-before but 125amp. 2 Each
60 60 All as per Srl item No 58 here-in-before but 250amp. 1 Each
61 61 All as per Srl item No 58 here-in-before but 400amp. 1 Each
62 62 M & L in repair of on load change over switch in existing LT panel with fixing arrangements 4 poles, 415 Volts, 160amp complete all as specified and directed. Make :- ABB/C&S/ HPL/ Havells/ Indo Asian. 2 Each\n
63 63 Supplying and laying in replacement XPLE insulated armoured (under ground) heavy duty electric cable with stranded aluminium conductor 1100 volts grade of grossectional area 16sqmm 2 core laid in trenches/ ducts/ through pipes/ in floor road/ along the pole etc complete all as specified and directed by Engineer-in-Charge. Note :- (a) Excavation earth work, brick protection and cushioning shall be measured and paid separately. 100 RM
64 64 All as per Srl item No 63 above but 95 Sqmm 3.5 core. 300 RM
65 65 All as per Srl item No 63 above but 70 Sqmm 3.5 core. 200 RM
66 66 All as per Srl item No 63 above but 50 Sqmm 3.5 core. 100 RM
67 67 Excavation in trenches not exc 1.5 m wide and n. exc 1.5 min depth for in soft loose soil including cutting road surface for poles stay, cable, pipes etc getting out all as specified and directed. 80 Cum
68 68 Returning filling in including spreading levelling watering and well ramming in layers nexc 25 cm thick in soft loose soil complete all as specified and directed. 20 Cum
69 69 Removal of excavated surplus/spoil on a distance n.exc 50 m and deposting where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. 60 Cum
70 70 Supply and lay brick common burnt sub class "B" old size for protection of cables laid in trenches complete all as specified and directed. 1.5 Per 1000 Nos
71 71 M&L for sand cushioning trenches using fine sand to under ground cable, laid in two layers 15cm before layingthe cable & 8cm after laying the cable complete all as specified and directed. 15 Each Set
72 72 M & L for earthing complete with galvansed steel earth plates electrode 60cmX600cmX6mm thick burried directly in ground ( earth pit not less than 2.25 mtr deep below the ground level ) with edge of the plate not less then 1.5 mtr below the ground level connection to GI galvanised Iron strp 25mmX3mm as earthing lead by means of bolts/nuts chick nut & washers of GI or steel all ghown in electrical plate No 5 of SSR part I connection to feeder piller all as specified including watering GI pipe 40mm bore medium grade PCC chamber using PCC 1:3:6 type C2 and PCC C1 for cover funnel & wire mesh all as specified & directed by Engr-in-charge 12 Each set
73 73 M&L LED display conforming to A15004 Part 3 with Hindi/English letters, scrolling, flashing mode and variable brightness. Aluminium cabnit with powder coated finish and toughonal glass front with 50 mm mounting arrangement in steel (3 on grade). 80 Sq feet
74 74 Supply only copper sulphate of approved make by HQ E-in-C's Branch. 400 KG
75 75 Supply only Soda ash made of 100% sodium cabonate all as specified and directed. Make :- Tata Chemicals/Gracim / Approved ISI brand. 100 KG
76 76 Supply only Chlorine test kit with coloured ample complete with all testing fitmtnts and OT solution in Rexine finish box. Make :- CHLOROMAX or equivalent and approved. 10 Each
77 77 Supply only water suction PVC hose pipe 50mm (2) dia ISI 2482/90. Make :- Deep/Jyoti 30 RM
78 78 Supply only nylone rope 25mm dia of approved quality as as directed. 60 RM
79 79 Supply only calcium based granule dis-infectant for water treatment more stable than chlorine gas and stronger than bleaching powder and sodium hypo chloride (Packing in 45Kg Plastic drum) complete all as specified and directed. Make : As per approved make by HQ E-in-C's branch. 2500 KG
80 80 Supply only aluminum ferric white (Crystal type) make as per approved make by HQ E-inC's Branch. 1500 KG
81 81 Supply only bleching powder Gde-ll confirming to IS-1065/89 revise with minimum chloride available 33.3% packed in 25/50 kg tight screwed bags complete all as specified and directed. Make : As per approved make by HQ E-in-C's Branch. 3000 KG
82 82 Comprehensive maintanance of stretcher lift at 172 Mil Hospital , Tibri of Make: OTIS ,including periodical inspection and servicing, replacement of minor defective parts, safety test etc complete all as per manufacture's offer all as directed by Engineer-in-charge 10 Each Job
83 83 Supply and fixed the following items to be carried out to the subject Machine No F00216 of the above lift :- Kit door guide/ shim / Hardware all as specified and directed. 4 Each
84 84 Supply and fixing Car ceiling for BED Elevator of lift installed at 172 MH all as directed 1 Each
85 85 Supply and fixing of Electronic door protection complete kit all as directed and specified . 2 Set
86 86 M& L for Car Header with motor and drive for the lift in replacement of the unserviceable drive all as directed. 1 Each
87 87 M&L for fixing of Infrared Sensan of closing and opening of door by dismantling the old one all as directed. 1 Each
88 88 M&L wiring of the Lift Panel upto the Header of the lift door with control wiring and repalcement of the defective parts of the panel including contactors, timer, phase preventor, relay etc and testing of the panel for improved performance all as directed by the Engineer-In-charge 1 Each Job
89 89 S&F for safety inspection of lift by the Govt agency or third party agency approved by Govt/ Punjab Govt arrangement of inspection/ inspection team by depositing the fees for inspection and obtain the safety certificate . If any observations given by the inspection team the contractor will rectify the observations and re-inspection of the lift for the proper safety all as per directed by Engineer-in-Charge. 1 Each Job
90 90 Supply and fixing of new fire alarm control panel in repair complete industrial type of 8 zone conventional type, electronic candel lamp test controls LCD display, battery backup complete including testing for no faults all as directed and specified 2 Each
91 91 Supply and fixed electronic hooter industrial type of range 5 KM single phase 230 volt ,6000 RPM aluminium body completeall as directed and specified 2 Each
92 92 Supply and fixing of suction sweeper including electric motor of 3 HP capacity 440 volt 50 Hz with a head of min 20 mtr including suction header, suction provision, electric cable, angle iron frame and wheel for heavy and extensive uses all as directed by Engineer in charge. Contractor has to provide written gurantee for one year for the suction sweeper for smooth functioning. 1 Each
93 93 M&L for repair / serviceing of DOL Starter of pump motor of swimming pool including replacement of burnt items, defective parts etc all as directed by Engineer-in-charge 1 Job
94 94 M&L for disconnecting and taking out pump motor of capcity 10-15HP from existing position, dismantaling the burnt motor, rewinding the motor with super enamelled copper winding wire as per existing gauge, size including insulation material cotton tape, varnish , insulation paper , sleevs, lugs etc and testing for improved performance as per the satisfaction of Engineer-in-charge 2 Job
95 95 Supply and fixing in replacement of Nylon brush of superior quality for suction sweeper machine of existing size directed by Engineer-in-charge 6 Each
96 96 Supply and fixing of PVC pipe corrugated type as per existing of size 40/50mm dia all as directed by Engineer-In-charge 50 RM
97 97 Supply and fixing of pressure gauge of range 0 to 100 Kg/CM2 of existing make all as directed by Engineer-in- Charge 3 Each
98 98 Supply & fixing in repairs CI sluice valve with forged brass stem class PN 1.6 ISI marked with stainless steel spindal and flanged both ends of size 200mm dia bore with hand wheel complete all as directed . 2 Each
99 99 Supply & fixing CI Non return valve forged brass 200 mm bore PN 1.6 complete with flanged on both ends all as specified and directed. 2 Each
100 100 Supply and fixing in repairs CI sluice valve with forged brass stem class PN- 1.6 ISI marked with stainless steel spindal and flanged both ends of size 150mm dia bore with hand wheel complete all as specified and directed. 2 Each
101 101 Supply and fixing CI Non return valve forged brass 150mm bore PN 1.6 complete with flanged on both ends all as specified and directed. 2 Each
102 102 Supply and fixing of CI fittings including Tee, vbends, nipple, coupling etc complete all as specified and directed. 150 Kg
103 103 M & L for cleaning of UG sump of capacity 50000 Gallons (Swiming pool collection sump) as described below ):-\n(i) Dewatering with submersible / sludge pump to empty the sump tank upto base level (ii) Removing sludge from sump wall and bottom with the help of special sledge pump and remaining dirt which may have hidden in rogh slots of the bottom mannually with brush (iii) After cleaning the sump apply bleaching powder for disinfection of sump (iv) The sludge / waste removed from the sump shall be disposed off in dumping ground as directed by Engineer - in - charge 1 Each Job
104 104 M&L air termination single pointed aluminium rod,30 CM long of dia 12mm including insulators completeall as directed and specified 60 Each
105 105 Supply and fixing aluminium strip 25mm x 3mm complete with saddle and fixing screws for fitting strip. 250 RM
106 106 Supply and fixing GI strip 32mm x 6mm complete with saddle and fixing screws for fitting strip. 250 RM
107 107 Supply and fixing test point terminal block made of GI plate size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex.head screw all as specified and directed 15 Each
108 108 Supply installaton commissioning and testing of All in One solar street lighting system complete with solar Panel, with IP 65 protection, solar panel, battery, charging circuit, LED driver are integrated in single casing, mounted on existing pole, connecting cable battery box reflector on its back including LED light of 40 W and above, Aluminum alloy case, built in pipe mounting bracket, 120degrees wide lighting angle, efficiency min 95% . Make : Bajaj /Halonix/ Philips/ Crompton/ Havells 15 Each
109 109 Supply and fixing in replacement of flat submersible electric cable, spl PVC insulated with bare bunched copper conductor for submersible pump,1100 volts grade, 3 core, cross-sectional area 6 sqmm complete all as specified and directed. 100 RM
110 110 All as per Srl item No 111 here-in-before but cross-sectional area 10 sqmm. 100 RM
111 111 S & F MCCB 250 Amp 25 KA 415 volt FP adjustable thermal & fixed Magnetic setting phase indication lamps all as specified and directed by Engineer-in-Charge. 4 Each
112 112 S & F MCCB 160 Amp 25 KA 415 volt TP adjustable thermal& fixed Magnetic setting all as specified and directed by Engineer-in-Charge. 4 Each
113 113 S & F MCCB 100 Amp 16 KA, 415 volt FP adjustable thermal& fixed Magnetic setting indication lamps all as specified and directed by Engineer-in-Charge. 4 Each
114 114 S & F MCCB 63 Amp 16 KA, 415 volt FP adjustable thermal& fixed Magnetic setting indication lamps all as specified and directed by Engineer-in-Charge. 4 Each
115 115 Supply & fixing digital type Voltmeter 0 to 500 volts LED display with slector switch complete all as directed and specified\n 6 Each
116 116 Supply & fixing digital type Ameter 0 to 100 Amps LED display with slector switch complete all as directed and specified\n 6 Each
117 117 Supply & fixing in repair CI sluice valve with forged brass stem class PN-1.6 ISI marked with stainless steel spindal and flanged both ends of size 100mm dia bore with hand wheel all as directed. 5 Each
118 118 Supply & fixing CI Non return valve forged brass 100 mm bore PN 1.6 complete with flanged on both ends all as specified and directed. 5 Each
119 119 Supply, installing , testing and commisioning factory made outdoor type dust and vermin proof LT panel board cubical type double door hinged type compartmentised of suitable size 415 volts, AC 50 Hz made of CRCA sheet 3.15 mm thick machine pressed and angle iron frame work of szie 40x40x6.0 mm grouted in PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates ) sheet powder coated inside and out side complete including 4 pole copper bus bar of capacity 200 amp mounted on procelain insulators enclosed in chamber and connection from incoming and outgoing electric cable with suitable size of thimbles /lugs with openable shutter on both sides and comprising of the following:-\n(i) Incoming MCCB 4 Pole 160Amps capacity - 01 Nos\n(ii) Outgoing MCCB 4 pole 100 Amps capacity - 03 Nos (pump)\n(iii) Starter for the pump of capacity upto 15HP - 03 Nos (Pumps)\n(iii) single phase preventor - 01 Nos\n(iv) Phase corrector and capacitor - 01 Each\nall as dircted by Engineer in charge \nNote: Drawing of the LT Panel should got approval of Engineer in Charge before manufacturing. 2 Each
120 120 Supply and fixing of fire bricks of primary and secondary fire chamber in double layer by removing the old damaged bricks and testing for fire resistance all as dircted by Engineer-in-Charge. 2 Each Job
121 121 Supply and fixing of temp control gauge as per existing all as directed 2 Each Job
122 122 Repair / replacement of glass type control wiring of control panel and of whole plant with new wire including testing all as direced by Engineer-in-Charge 1 Each Job
123 123 M & L for painting of the whole chimney of the incenerator by scrabing out the old paint and preparing the surface for new painting, applying one coat of red enameled paint and two coat of sliver colour glosy paint, scrubing out the old paint of existing primary, seconday chember, ID Fans, Motors, Sign boards, Pipes, Angle Irons, Channels etc and applying two coats of Alluminium paint with all colour coads with the full satisfaction of engineer in charge all as dircted and specified 1 Each Job
124 124 Repair to the contrrol panel of the plant by disconnecting all the electric connection and repalcement of all defective contractors, auxilary blocks, relays, wiring etc with the full satisfaction of engineer in charge 1 Each Job
125 125 M & L 3 pole power contractor MNX - 45 of make L&T or equivalent all as directed by Engineer - in - Charge 4 Each
126 126 M & L 3 pole power contractor MNX - 25 of make L&T or equivalent all as directed by Engineer - in - Charge 4 Each
127 127 M & L 3 pole power contractor 3TF 35 of make Siemens or equivalent all as directed by Engineer - in - Charge 3 Each
128 128 M & L of overload relay of range 15-25 Amps capacity all as directed by Engineer in Charge 4 Each
129 129 M & L of overload relay of range 30-50 Amps capacity all as directed by Engineer in Charge 4 Each
130 130 M & L of 3 phase Timer, 230 Volt, 50 Hz, Amps 15 upto 50Amp capacity all as directed by Engineer in Charge 4 Each
131 131 M & L of single phase preventor 230 Volt, 50 Hz all as directed by Engineer in Charge 4 Each
132 132 Supply and fixing in replacement of push button of Red, green, and exiting colour 230 Volt all as specified and directed 12 Each
133 133 Repair / serviceing of the firing motor of the incenerator including repair / replacement of the solenoid valves, transformer, relays, winding etc with full satisfaction of the Engineer - in - charge all as directed 1 Each Job
134 134 Supply and fixing in replacement of heating elements suitable for drying tumbler of 20 kg capacity all as specified and directed 2 Each
135 135 S&F automatic voltage regulator suitable for 100 KVA Servo Voltage Stabilizer all as directed by Engineer in Charge 2 Each
136 136 Taking out, dismantaling the Servo Voltage Stabilizer from foundation and transporting the same to workshop, taking out of all burnt winding wires by strip opening of 3phase voltage stabilizer of any make, rewinding the stabilizer with super enamled copper winding wire of required gauge and quantity including varnishing insulation sheet cotton, glass sleave etc as required, reassembling,testing, transporting back to site from workshop, installing back and making connection and again testing for 100 KVA Servo Voltage Stabillizer for improved performance all as specified and directed by Engineer-in-Charge 1 Each
137 137 Supply and fixing chain pully block of 5 Ton capacity industrial type heavy duty all as specified and directed. 2 Each
138 138 Copper winding wire of different gauge and size for servo voltage stabilizer, alternator rewinding and other works as directed by Engineer-in-charge 100 Kg
139 139 S & F transformer oil for voltage stabilizer all as directed by Engineer-In-charge 80 Ltr
140 140 M & L for cleaning of UG sump of sewage collection sump of capacity 50000 Gallons (Sewage collection sump) as described below ):-\n(i) Dewatering with submersible / sludge pump to empty the sump tank upto base level (ii) Removing sludge from sump wall and bottom with the help of special sledge pump and remaining dirt which may have hidden in rogh slots of the bottom mannually with brush (iii) After cleaning the sump apply bleaching powder for disinfection of sump (iv) The sludge / waste removed from the sump shall be disposed off in dumping ground as directed by Engineer - in - Charge 4 Each Job
141 141 Disconnecting and taking out motor from non clog sewage pump horizontal type 65 LPS , 30 mtr head 3 phase 440 volt including pump, dismantling the burnt motor, rewinding the motor with supper enamelled copper winding wire as per existing gauge, size including suitable insulation material cotton type, varnish, insulation paper, sleeves and dry and baking etc connections etc connections etc and assembling complete after duly repair installation, commissioning and testing upto the satisfactory working performance complete all as specified and directed. Note :- All T&P vehicle and manpower will be provided by contractor. The repair of pump motor should vbe carried out within 72 hours after intimation of breakdown to ghe contractor by means of whats up, massage, phone calls, letter etc. Contractor should carry out testing for smooth functioning of pump motor at existing position within 72 hours failing which a penalty of Rs. 2000/- per days will be levived on the contractor. 3 Each Job
142 142 S&F in replacement of impeller bronze sutaible for sewage pump horizontal type 65 LPS, 30 mtr head 3 phase 440 volt pumping set complete all as specified and directed. 3 Each
143 143 S&F in replacement of ball bearing as per sample for sewage pump horizontal type 65 LPS, 30 mtr head 3 phase 440 volt for both side front and rear side bearing of existing size etc complete complete all as specified. 3 Set of two
144 144 Disconnecting and taking out motor from non clog sewage pump horizontal type 45 LPS , 30 mtr head 3 phase 440 volt including pump, dismantling the burnt motor, rewinding the motor with supper enamelled copper winding wire as per existing gauge, size including suitable insulation material cotton type, varnish, insulation paper, sleeves and dry and baking etc connections etc connections etc and assembling complete after duly repair installation, commissioning and testing upto the satisfactory working performance complete all as specified and directed. Note :- All T&P vehicle and manpower will be provided by contractor. The repair of pump motor should vbe carried out within 72 hours after intimation of breakdown to ghe contractor by means of whats up, massage, phone calls, letter etc. Contractor should carry out testing for smooth functioning of pump motor at existing position within 72 hours failing which a penalty of Rs. 2000/- per days will be levived on the contractor. 3 Each Job
145 145 S&F in replacement of impeller bronze sutaible for sewage pump horizontal type 45 LPS, 30 mtr head 3 phase 440 volt pumping set complete all as specified and directed. 3 Each
146 146 S&F in replacement of ball bearing as per sample for sewage pump horizontal type 45 LPS, 30 mtr head 3 phase 440 volt for both side front and rear side bearing of existing size etc complete complete all as specified. 3 Set of two
147 147 S&F in repair fully automatic star delta starter (FASD) suitable for 10-15 HP motor all as specified and directed by Engineer-in-Charge. 2 Each
148 148 S&F of XLPE cable 3 core 16 Sqmm copper conductor for connection the sewage pump from panel all as specified and directed. 50 RM
149 149 Supply and installation in repairs of monoblock pump set with electric driven motor, single phase, 230 volts, 2800 rpm, 01/0.7 KW having suction and delivery 25mm x 25mm all as specified and directed. 2 Each
150 150 M&L for repair of all in one solar street light of capacity 40 watt including replacement of defective solar Panel, unserviceab le wiring circuit, LED light panel etc and checking of the solar light for complete functioning all as specified and directed by Engineer-in-Charge. 10 Each
151 151 S&F battery dry type including initial charging for all in one solar street light 40 watt capacity all as directed and specified by Engineer-in-Charge. 10 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail