Road And Building Department-RBD has published Construction Of Academic Building Of Sushilabati Govt . Womens College At Rourkela Under World Bank Assistance Programme ( Ohepee ) Phase-1 For The Year 2020-21. Submission Date for this Tender is 03-12-2020. Building Work Tenders in Rourkela Odisha. Bidders can get complete Tender details and download the document.
Name of Work: Construction of Academic Building of Sushilabati Govt. Womens College at Rourkela Under World Bank Assistance Programme (OHEPEE) Phase – 1 for the year 2020-21. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | CIVIL WORKS (PART-I) | BI01010001010000000000000515BI0100001112 | ||
2 | 1.01 | PART-A & PART-B | BI01010001010000000000000515BI0100001113 | ||
3 | 1.02 | Earthwork in excavation of foundation in hard soil or gravelly soil within 50m initial lead and 1.5m, initial lift including shoring,shuttering, propping bullahs, piling,dewatering from foundation, supplying & working pumps & staking the excaveted materials away from the working area including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth including cost, conveyance, taxes, cess, royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge | BI01010001010000000000000515BI0100001114 | 1414.63 | Cum |
4 | 2 | Supplying and filling in foundation and plinths with sand well watered and compacted including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, watering, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001115 | 1426.71 | Cum |
5 | 3 | Providing and laying plain cement concrete (1:3:6)(using branded cement) in foundation using 40 mm size hard crusher broken granite metal of approved quality from approved quarry including mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period including cost of all material, labour, conveyance, loading and unloading, taxes,cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc. ,complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001116 | 172.58 | Cum |
6 | 4 | Providing lifting , hoisting and laying reinforced cement concrete of M 20 grade(using branded cement) to the following structural member or in places as shown in the drawing for all floors with 20 mm and down graded size hard crusher broken granite chips of approved quality from approved quarry including mixing and vibro compacting to proper shape and size, level and plumb and finishing the exposed surfaces smooth (if required by grouting / providing plaster with cement mortar 1:4 wherever necesary without any extra cost) scaffolding, including watering and curing for the required period including providing strong, rigid, levelled and plumbed centring and shuttering to required shape and size, for floors with steel centring materials, with all necessary bracing and ties and supports pockets for electrical conduits, pipes, PH pipes, for hooks or boxes, switchboards and insert plates, clamps and extension bars, etc, including dismantling the same after the required interval from the date of casting, including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering,curing, sundries. tools and plants etc. complete as per direction of the engineer-in-charge, but excluding cost of steel reinforcement. | BI01010001010000000000000515BI0100001117 | ||
7 | 4.01 | i) R.C.C Column Foundation | BI01010001010000000000000515BI0100001118 | 314.95 | Cum |
8 | 4.02 | ii) R.C.C Plinth Beam | BI01010001010000000000000515BI0100001119 | 37.84 | Cum |
9 | 4.03 | iii) R.C.C Column & Beam in Superstructure | BI01010001010000000000000515BI0100001120 | ||
10 | 4.04 | a) Ground Floor | BI01010001010000000000000515BI0100001121 | 86.91 | Cum |
11 | 4.05 | b) 1st Floor | BI01010001010000000000000515BI0100001122 | 111.59 | Cum |
12 | 4.06 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001123 | 9.72 | Cum |
13 | 4.07 | iv) R.C.C Lintel | BI01010001010000000000000515BI0100001124 | ||
14 | 4.08 | a) Ground Floor | BI01010001010000000000000515BI0100001125 | 24.42 | Cum |
15 | 4.09 | b) 1st Floor | BI01010001010000000000000515BI0100001126 | 28.02 | Cum |
16 | 4.1 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001127 | 0.72 | Cum |
17 | 4.11 | v) R.C.C Chajja | BI01010001010000000000000515BI0100001128 | ||
18 | 4.12 | a) Ground Floor | BI01010001010000000000000515BI0100001129 | 73.93 | Sqm |
19 | 4.13 | b) 1st Floor | BI01010001010000000000000515BI0100001130 | 132.26 | Sqm |
20 | 4.14 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001131 | 0.9 | Sqm |
21 | 4.15 | vi) R.C.C Stair case | BI01010001010000000000000515BI0100001132 | ||
22 | 4.16 | a) Ground Floor | BI01010001010000000000000515BI0100001133 | 8.17 | Cum |
23 | 4.17 | b) 1st Floor | BI01010001010000000000000515BI0100001134 | 8.1 | Cum |
24 | 4.18 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001135 | 2.17 | Cum |
25 | 4.19 | vii) R.C.C Roof Slab | BI01010001010000000000000515BI0100001136 | ||
26 | 4.2 | a) Ground Floor | BI01010001010000000000000515BI0100001137 | 122.98 | Cum |
27 | 4.21 | b) 1st Floor | BI01010001010000000000000515BI0100001138 | 162.9 | Cum |
28 | 4.22 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001139 | 3.83 | Cum |
29 | 4.23 | viii) R.C.C Shelves | BI01010001010000000000000515BI0100001140 | ||
30 | 4.24 | a) 1st Floor | BI01010001010000000000000515BI0100001141 | 113.14 | Sqm |
31 | 5 | Supplying Cutting, straightening tor steel of primary steel / HYSD bars producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) & of approved grade etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (Linear measurement will be taken and quantity will be calculated on standard weight for all heights) complete as per specification & direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001142 | ||
32 | 5.01 | a) Ground Floor | BI01010001010000000000000515BI0100001143 | 648.94 | Qntl |
33 | 5.02 | b) 1st Floor | BI01010001010000000000000515BI0100001144 | 416.61 | Qntl |
34 | 5.03 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001145 | 24.37 | Qntl |
35 | 6 | Fly Ash brick masonry in cement mortar (1:6) (Using Branded Cement) in foundation & plinth using Fly Ash bricks of 23x11x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per specification & direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001146 | ||
36 | 6.01 | a) Ground Floor | BI01010001010000000000000515BI0100001147 | 240.39 | Cum |
37 | 7 | Providing Fly Ash brick masonry work in super structure using 230 mm X 110 mm X 80 mm (with dimensional tolerance of ± 2% ) Fly Ash bricks having crushing strength not less than 75 kg. / sq cm, mortar of mix 1:6 (1 cement : 6 sand),(using branded cement) immersing the bricks for minimum 6 hrs in water before use, with all necessary projections, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc., complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001148 | ||
38 | 7.01 | a) Ground Floor | BI01010001010000000000000515BI0100001149 | 233.17 | Cum |
39 | 7.02 | b) 1st Floor | BI01010001010000000000000515BI0100001150 | 357.79 | Cum |
40 | 7.03 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001151 | 41.65 | Cum |
41 | 8 | Fly Ash brick masonry in cement mortar (1:4) (Using Branded Cement) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per specification & direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001152 | ||
42 | 8.01 | a) Ground Floor | BI01010001010000000000000515BI0100001153 | 8.48 | Cum |
43 | 8.02 | b) 1st Floor | BI01010001010000000000000515BI0100001154 | 36.07 | Cum |
44 | 9 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) (Using Branded Cement) with screened and washed sharp sand for mortar and finished smooth to the inside rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as per specification & direction of Engineer-in-charge.. | BI01010001010000000000000515BI0100001155 | ||
45 | 9.01 | a) Ground Floor | BI01010001010000000000000515BI0100001156 | 1339.8 | Sqm |
46 | 9.02 | b) 1st Floor | BI01010001010000000000000515BI0100001157 | 2944.94 | Sqm |
47 | 9.03 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001158 | 393.32 | Sqm |
48 | 10 | Providing 12 mm thick cement mortar 1:6 (1 cement : 6 sand )(using branded cement) to outside surface / plumbed surface of masonry, raking out joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing grooves as shown in the drawing, including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering. curing, sundries, tools and plants etc. complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001159 | ||
49 | 10.01 | a) Ground Floor | BI01010001010000000000000515BI0100001160 | 1588.68 | Sqm |
50 | 10.02 | b) 1st Floor | BI01010001010000000000000515BI0100001161 | 2521.63 | Sqm |
51 | 10.03 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001162 | 393.32 | Sqm |
52 | 11 | Providing Kota tiles of sizes above 0.10 sqm having minimum thickness 16mm of approved make and shade, dressed, rubbed and polished, bottom coated with neat cement slurry in corridors floor ,treads or steps and landing fixed with neat cement slurry, over 20 mm thick cement mortar (1:4)(1 cement : 4 course sand) (Using Branded Cement) to masonry or concrete surfaces to proper level / slope and joints filled with white cement of approved quality polishing, washing and acid cleaning, including cost of all materials, conveyance, royalties, taxes,cess, labour, scaffolding, watering, curing, sundries, T&P etc. complete as per specification & direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001163 | ||
53 | 11.01 | a) Ground Floor | BI01010001010000000000000515BI0100001164 | 1612.37 | Sqm |
54 | 11.02 | b) 1st Floor | BI01010001010000000000000515BI0100001165 | 990.89 | Sqm |
55 | 12 | Providing Kota tiles of sizes upto 0.10 sqm having minimum thickness 16mm of approved make and shade in dado/skirting and rises of steps to any height in all floors, fixed with neat cement slurry, after soaking the tiles in water, over 12 mm thick cement mortar (1:3)(1 cement : 3 sand) mix, joint pointed with cement mixed with matching pigment to match the shade of the tiles , including washing and cleaning with oxalic acid, including cost of all materials, conveyance, royalties, taxes,cess, labour, scaffolding, watering, curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001166 | ||
56 | 12.01 | a) Ground Floor | BI01010001010000000000000515BI0100001167 | 85.11 | Sqm |
57 | 12.02 | b) 1st Floor | BI01010001010000000000000515BI0100001168 | 84.27 | Sqm |
58 | 13 | Supplying & fitting, fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCLVEKA LTD) Casement Door-60-series duly Manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames 102mm x 60mm x 2.25mm for casement Door Sash Profile and 74mm x 60mm x 2.5mm mullion profile capable of mounting single glazing system structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 2.0mm prefabricated & welded through fusion welding the door sash shall be fitted with 12mm thick WPC Board of Greenply make duly fixed with EPDM weathering seal resistant acessories like clipping locking system made of aluminium 1 no per set of sashes and the system is to be installed at the site using anchor fasteners silicon rubber sealant easy glazing, deglazing at site etc including cost & conveyance of all materials acessories labour charges, cess, materials & product conforming to ASTM D 638-14 EN-477-95 and other applicable codes and standards. | BI01010001010000000000000515BI0100001169 | ||
59 | 13.01 | a) Ground Floor | BI01010001010000000000000515BI0100001170 | 52.92 | Sqm |
60 | 13.02 | b) 1st Floor | BI01010001010000000000000515BI0100001171 | 60.05 | Sqm |
61 | 13.03 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001172 | 2.52 | Sqm |
62 | 14 | Supplying & fitting, fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCL VEKA LTD) Three track three panel sliding window-60-series duly Manufactured using UPVC reinforced profiles of 108mm x 45mm x 2.5mm for outer frames and window sash of 39mm x 58mm x 2.5mm capable of mounting single glazing system structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window frame shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant and the system is to be installed using Reinforced large coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost & conveyance of all materials acessories labour charges, Cess, materials & product conforming to ASTM D 638-14 EN-477-95 and other applicable codes and standards. | BI01010001010000000000000515BI0100001173 | ||
63 | 14.01 | a) Ground Floor | BI01010001010000000000000515BI0100001174 | 34.8 | Sqm |
64 | 14.02 | b) 1st Floor | BI01010001010000000000000515BI0100001175 | 34.29 | Sqm |
65 | 15 | Supplying & fitting, fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCL VEKA LTD) Ventilator / Top Hung-60-series duly Manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames, 75mm x 60mm x 2.25mm for casement Windows Sash Profile capable of mounting single glazing system structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window sash shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost & conveyance of all materials acessories labour charges, Cess, materials & product conforming to ASTM D 638-14 EN-477-95 and other applicable codes and standards. | BI01010001010000000000000515BI0100001176 | ||
66 | 15.01 | a) Ground Floor | BI01010001010000000000000515BI0100001177 | 3.24 | Sqm |
67 | 15.02 | b) 1st Floor | BI01010001010000000000000515BI0100001178 | 10.72 | Sqm |
68 | 16 | Supplying & fitting, fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCLVEKA LTD) Casement window with top fixed-60-series duly Manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames 75mm x 60mm x 2.25mm for casement window Sash Profile and 74mm x 60mm x 2.5mm mullion profile capable of mounting single glazing system structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.50 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant acessories like clipping locking system made of aluminium 1 no per set of sashes and the system is to be installed at the site using anchor fasteners silicon rubber sealant easy glazing, deglazing at site etc including cost & conveyance of all materials acessories labour charges, Cess, materials & product conforming to ASTM D 638-14 EN-477-95 and other applicable codes and standards. | BI01010001010000000000000515BI0100001179 | ||
69 | 16.01 | a) Ground Floor | BI01010001010000000000000515BI0100001180 | 119.7 | Sqm |
70 | 16.02 | b) 1st Floor | BI01010001010000000000000515BI0100001181 | 101.11 | Sqm |
71 | 17 | Providing and laying plain cement concrete (1:2:4)(using branded cement) in plinth protection using 12 mm size hard crusher broken granite chips of approved quality from approved quarry including mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period including cost of all material, labour, conveyance, loading and unloading, taxes, cess,royalties, scaffolding, watering, curing, sundries, tools and plants,etc. ,complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001182 | ||
72 | 17.01 | a) Ground Floor | BI01010001010000000000000515BI0100001183 | 12.97 | Cum |
73 | 18 | Providing and applying primer over the plastered surfaces with 1 coat of primer (Water bound wall cement primer) of approved quality and shade, using the required quantity of primer as specified by the manufacturer to give an even shade including cost of all materials, labour, conveyance, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001184 | ||
74 | 18.01 | a) Ground Floor | BI01010001010000000000000515BI0100001185 | 4591.5 | Sqm |
75 | 18.02 | b) 1st Floor | BI01010001010000000000000515BI0100001186 | 6807.01 | Sqm |
76 | 18.03 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001187 | 878.64 | Sqm |
77 | 19 | Providing and applying Distempering with approved quality Distemper (Burger Make) mix with adhesive of required amount to the interior plastered surfaces at all levels and heights by applying 2 coats using the required quantity of Distemper as specified by the manufacturer to give an even shade , watering the surface before applying and curing for the required period, including cleaning and smoothening the surface thoroughly including cost of all materials, labour, conveyance, taxes, cess, royalties, scaffolding, watering, curing, tools and plants, etc., complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001188 | ||
78 | 19.01 | a) Ground Floor | BI01010001010000000000000515BI0100001189 | 3672.85 | Sqm |
79 | 19.02 | b) 1st Floor | BI01010001010000000000000515BI0100001190 | 4791.38 | Sqm |
80 | 19.03 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001191 | 454.66 | Sqm |
81 | 20 | Providing and applying painting over the plastered surfaces with water proofing cement paint of approved quality and shade on new work two coat to give an even shade including cost of all materials, labour, conveyance, taxes,cess, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001192 | ||
82 | 20.01 | a) Ground Floor | BI01010001010000000000000515BI0100001193 | 918.65 | Sqm |
83 | 20.02 | b) 1st Floor | BI01010001010000000000000515BI0100001194 | 2015.63 | Sqm |
84 | 20.03 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001195 | 393.32 | Sqm |
85 | 21 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) (Using Branded Cement) using 4.7mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of roof slab including watering and curing with cost, conveyance, royalties and taxes of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as per specification & direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001196 | ||
86 | 21.01 | a) Ground Floor | BI01010001010000000000000515BI0100001197 | 388.65 | Sqm |
87 | 21.02 | b) 1st Floor | BI01010001010000000000000515BI0100001198 | 1386.26 | Sqm |
88 | 21.03 | c) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001199 | 30.76 | Sqm |
89 | 22 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per specification & direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001200 | ||
90 | 22.01 | a) Ground Floor | BI01010001010000000000000515BI0100001201 | 256.8 | Kg |
91 | 22.02 | b) 1st Floor | BI01010001010000000000000515BI0100001202 | 467.62 | Kg |
92 | 23 | Providing, Fitting & Fixing of 100 mm dia PVC Rain water pipe with cost, conveyance, royalties of all materials with cost of all labour,labour cess, and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. | BI01010001010000000000000515BI0100001203 | ||
93 | 23.01 | a) 1st Floor | BI01010001010000000000000515BI0100001204 | 82.53 | Rmt |
94 | 23.02 | b) 2nd Floor (Head Room) | BI01010001010000000000000515BI0100001205 | 90 | Rmt |
95 | 24 | P.H. WORKS (PART-II) | BI01010001010000000000000515BI0100001206 | ||
96 | 24.01 | Academic Block | BI01010001010000000000000515BI0100001207 | ||
97 | 24.02 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC pipes, confirming to ASTM - D - 1785 . 89 (sch 80) and pipe fitting of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001208 | ||
98 | 24.03 | A)Ground floor | BI01010001010000000000000515BI0100001209 | ||
99 | 24.04 | i)20mm dia PVC Pipe | BI01010001010000000000000515BI0100001210 | 70 | Mtrs. |
100 | 24.05 | ii)25mm dia PVC Pipe | BI01010001010000000000000515BI0100001211 | 20 | Mtrs. |
101 | 24.06 | iii)32mm dia PVC Pipe | BI01010001010000000000000515BI0100001212 | 35 | Mtrs. |
102 | 24.07 | B)First floor | BI01010001010000000000000515BI0100001213 | ||
103 | 24.08 | i)20mm dia PVC Pipe | BI01010001010000000000000515BI0100001214 | 40 | Mtrs. |
104 | 24.09 | ii)25mm dia PVC Pipe | BI01010001010000000000000515BI0100001215 | 20 | Mtrs. |
105 | 24.1 | iii)32mm dia PVC Pipe | BI01010001010000000000000515BI0100001216 | 40 | Mtrs. |
106 | 24.11 | C)On Roof fo First Floor | BI01010001010000000000000515BI0100001217 | ||
107 | 24.12 | i)32mm dia PVC Pipe | BI01010001010000000000000515BI0100001218 | 80 | Mtrs. |
108 | 24.13 | ii)40mm dia PVC Pipe | BI01010001010000000000000515BI0100001219 | 40 | Mtrs. |
109 | 25 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001220 | ||
110 | 25.01 | i)15mm dia CP angle stop cock (Jaquar)CON-CHR-059KN | BI01010001010000000000000515BI0100001221 | 37 | Each |
111 | 25.02 | ii)15mm dia CP long body bib cock (Jaquar Make)CON-107KN | BI01010001010000000000000515BI0100001222 | 5 | Each |
112 | 25.03 | iii)15mm dia CP two way bib cock (Jaquar)CON-041KN | BI01010001010000000000000515BI0100001223 | 13 | Each |
113 | 25.04 | iv)15mm dia CP short body bib cock (Jaquar)CON-CHR-047KN | BI01010001010000000000000515BI0100001224 | 8 | Each |
114 | 25.05 | v)20mm dia CP concealed stop cock (Jaquar Make)CON-089KN | BI01010001010000000000000515BI0100001225 | 3 | Each |
115 | 25.06 | vi)25mm dia brass full way valve (Shakti make) | BI01010001010000000000000515BI0100001226 | 6 | Each |
116 | 25.07 | vii)32mm dia brass full way valve (Shakti make) | BI01010001010000000000000515BI0100001227 | 10 | Each |
117 | 25.08 | viii)40mm dia brass full way valve (Shakti make) | BI01010001010000000000000515BI0100001228 | 5 | Each |
118 | 25.09 | ix)25mm dia CP Health Faucet (Jaquar Make)ALD - CHR - 565 | BI01010001010000000000000515BI0100001229 | 13 | Each |
119 | 25.1 | x)125mm CP grating | BI01010001010000000000000515BI0100001230 | 41 | Each |
120 | 25.11 | xi)15mm CP Extension piece | BI01010001010000000000000515BI0100001231 | 64 | Each |
121 | 25.12 | xii)15mm size C.P. flange | BI01010001010000000000000515BI0100001232 | 64 | Each |
122 | 26 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001233 | ||
123 | 26.01 | i)2000 liters capacity PVC water storage tank roof of 1st floor | BI01010001010000000000000515BI0100001234 | 10 | Each |
124 | 27 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001235 | ||
125 | 27.01 | i)Ground floor | BI01010001010000000000000515BI0100001236 | 20 | Each |
126 | 27.02 | ii)First Floor | BI01010001010000000000000515BI0100001237 | 18 | Each |
127 | 28 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001238 | ||
128 | 28.01 | i)Ground floor | BI01010001010000000000000515BI0100001239 | 10 | Each |
129 | 28.02 | ii)First Floor | BI01010001010000000000000515BI0100001240 | 8 | Each |
130 | 29 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001241 | ||
131 | 29.01 | i)Ground floor | BI01010001010000000000000515BI0100001242 | 90 | Mtr |
132 | 29.02 | ii)First Floor | BI01010001010000000000000515BI0100001243 | 60 | Mtr |
133 | 30 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001244 | ||
134 | 30.01 | i)110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) | BI01010001010000000000000515BI0100001245 | 150 | Mtr. |
135 | 30.02 | ii)110mm U-PVC ‘P’ Trap (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001246 | 33 | Each |
136 | 30.03 | iii)110mm U-PVC door bend (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001247 | 36 | Each |
137 | 30.04 | iv)110mm U-PVC Plain bend (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001248 | 36 | Each |
138 | 30.05 | v)110mm U-PVC offset without ear (Ori Plast / Finolex / Supreme Make) | BI01010001010000000000000515BI0100001249 | 16 | Each |
139 | 30.06 | vi)110mm U-PVC Cowl (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001250 | 5 | Each |
140 | 30.07 | vii)110mm U-PVC Plain tee (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001251 | 15 | Each |
141 | 30.08 | viii)110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001252 | 18 | Each |
142 | 30.09 | ix)110mm U-PVC Plain shoe bend (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001253 | 5 | Each |
143 | 30.1 | x)110mm U-PVC Door cross tee | BI01010001010000000000000515BI0100001254 | 18 | Each |
144 | 30.11 | xi)110mm U-PVC Socket (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001255 | 48 | Each |
145 | 31 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001256 | ||
146 | 31.01 | i)580mm size Orissa pan (Hindware/Parryware/Neycer make) | BI01010001010000000000000515BI0100001257 | 8 | Each |
147 | 32 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001258 | ||
148 | 32.01 | i)10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) | BI01010001010000000000000515BI0100001259 | 13 | Each |
149 | 33 | Supplying all materials,labour,T&P and fitting and fixing vitrous Chaina washed down water Closet (European type water closet - EWC) with integral "P" or "S" type trap to the floor including wodden plug and chromoum plated screw including jointing the trap with soil pipe in CM(1:1) fixing plastic seat cover for washed down water closet with crmium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001260 | ||
150 | 33.01 | i)European Water Clost "S" trap(Parryware white) | BI01010001010000000000000515BI0100001261 | 5 | Each |
151 | 34 | Supplying all materials,labour,T&P and Bowl pattern urinal of the following sizes including connecting the urinal with 32mm dia PVC waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia cp dome west,15mm dia cp spreader including cutting holes in wall and making good the damages with supply of wooden plugs,screws and cement etc. all complete as per specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001262 | ||
152 | 34.01 | i)Half stall (Parryware make) | BI01010001010000000000000515BI0100001263 | 8 | Each |
153 | 35 | Supplying all materials,labour,T&P and fixing vitreous china squatting plate of following sizes with integral longitudinal flushing pipe including cutting the floor and mending good the damages embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete(1:5:10) using 40mm hard granite metal, including 6 mm thick white cement finishing at the top of the urinal foot plate etc. all complete as per specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001264 | ||
154 | 35.01 | i)Squatting urinal of 600mm x 350mm(Parryware make) | BI01010001010000000000000515BI0100001265 | 4 | Each |
155 | 36 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001266 | ||
156 | 36.01 | i)550mmx400mm W.H.basin (Hindware / Parryware / Neycer make)with 15mm dia C.P.pillar cock (Plaza make) with Pedestal | BI01010001010000000000000515BI0100001267 | 1 | Each |
157 | 36.02 | ii)Counter top basin | BI01010001010000000000000515BI0100001268 | 11 | Each |
158 | 37 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001269 | ||
159 | 37.01 | i)Towel ring CAN - BCH - 1121 | BI01010001010000000000000515BI0100001270 | 9 | Each |
160 | 38 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. | BI01010001010000000000000515BI0100001271 | ||
161 | 38.01 | i)600mmx125mm plate glass shelf (Jaquar) CAN - BCH - 1171N | BI01010001010000000000000515BI0100001272 | 1 | Each |
162 | 39 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. | BI01010001010000000000000515BI0100001273 | ||
163 | 39.01 | i)Large Size mirror with Frame (12x0.90x0.90)= 9.72 | BI01010001010000000000000515BI0100001274 | 9.72 | Sqm |
164 | 40 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001275 | ||
165 | 40.01 | i)CP soap holder (Jaquar)CAN - MCH - 1131N | BI01010001010000000000000515BI0100001276 | 22 | Each |
166 | 41 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001277 | 12 | Each |
167 | 42 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001278 | 5 | Each |
168 | 43 | Supplying all materials, labour, T&P and constructing Inspection Chamber of inside size 760mm x 760mm x 460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001279 | ||
169 | 43.01 | i)Inside size 76cmx76cmx46cm with 18” dia RCC MH cover | BI01010001010000000000000515BI0100001280 | 4 | Each |
170 | 44 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001281 | 4 | Each |
171 | 45 | Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site. | BI01010001010000000000000515BI0100001282 | ||
172 | 45.01 | i)Ground floor | BI01010001010000000000000515BI0100001283 | 5.39 | Cum |
173 | 45.02 | ii)First Floor | BI01010001010000000000000515BI0100001284 | 3.77 | Cum |
174 | 46 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001285 | ||
175 | 46.01 | i)Ground floor | BI01010001010000000000000515BI0100001286 | 3.77 | Cum |
176 | 46.02 | ii)First Floor | BI01010001010000000000000515BI0100001287 | 3.77 | Cum |
177 | 47 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001288 | ||
178 | 47.01 | i)Ground floor | BI01010001010000000000000515BI0100001289 | 3.77 | Cum |
179 | 47.02 | ii)First Floor | BI01010001010000000000000515BI0100001290 | 4.97 | Cum |
180 | 48 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001291 | ||
181 | 48.01 | i)Ground floor | BI01010001010000000000000515BI0100001292 | 53.9 | Sqm |
182 | 48.02 | ii)First Floor | BI01010001010000000000000515BI0100001293 | 53.9 | Sqm |
183 | 49 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) (1 cement : 1 sand) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge (ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed series to be pre-approved by the Engineer-in-charge) | BI01010001010000000000000515BI0100001294 | ||
184 | 49.01 | a)Kajaria tile 40cmx40cm (ground floor ) | BI01010001010000000000000515BI0100001295 | ||
185 | 49.02 | i)Ground floor | BI01010001010000000000000515BI0100001296 | 53.9 | Sqm |
186 | 49.03 | ii)First Floor | BI01010001010000000000000515BI0100001297 | 53.9 | Sqm |
187 | 50 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster (1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001298 | ||
188 | 50.01 | i)Ground floor | BI01010001010000000000000515BI0100001299 | 72.47 | Sqm |
189 | 50.02 | ii)First Floor | BI01010001010000000000000515BI0100001300 | 52.94 | Sqm |
190 | 51 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge ) | BI01010001010000000000000515BI0100001301 | ||
191 | 51.01 | a)Kajaria tile 40cmx25cm | BI01010001010000000000000515BI0100001302 | ||
192 | 51.02 | i)Ground floor | BI01010001010000000000000515BI0100001303 | 72.47 | Sqm |
193 | 51.03 | ii)First Floor | BI01010001010000000000000515BI0100001304 | 52.94 | Sqm |
194 | 52 | Supplying all materials, labour, T&P and providing and fixing in position M.S panelled door double leaved with M.S frame overall size including frame 1980mm Height x 1070mm Width made out of the following materials conforming to relevant Indian Standard specification, Frame: 35x35x6mm MS angle, Shutter stile: Top and bottom rail 25x25x3mm, MS angle door panell: 1.0mm C R sheet panell stiffner covering width of each leaf 19x5mm MS flat - 3nos on each leaf, Hinges size: 100mm - 6nos (3nos on each side) bought out as per ISS, Hold fast: 35x35x6mm, MS angle 175mm length bifurcated at the tip - 3nos on each side, Handle: 19x5mm MS flat fabricated - 4nos, Aldrop: 2nos bought out as per ISS, Tower bolt: 2nos bought out as per ISS, including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001305 | 756 | K.G |
195 | 53 | Supplying all materials, labour,T&P and painting two coats with any approved paint on new steel work as per specification and direction of the Engineer in charge . | BI01010001010000000000000515BI0100001306 | 42.53 | Sqm |
196 | 54 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001307 | ||
197 | 54.01 | i)110mm dia P.V.C. pipe | BI01010001010000000000000515BI0100001308 | 20 | Mtr. |
198 | 54.02 | ii)160mm dia P.V.C. pipe | BI01010001010000000000000515BI0100001309 | 40 | Mtr. |
199 | 55 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. | BI01010001010000000000000515BI0100001310 | ||
200 | 55.01 | i)MH size 0.91m x 0.91x0.91 m with 0.45 m (18” dia RCC Cover) | BI01010001010000000000000515BI0100001311 | 5 | Each |
201 | 56 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. | BI01010001010000000000000515BI0100001312 | ||
202 | 56.01 | i)1.40m dia x 2.00 m deep | BI01010001010000000000000515BI0100001313 | 1 | Each |
203 | 57 | 1 No of 50 Users septic tank | BI01010001010000000000000515BI0100001314 | ||
204 | 57.01 | a)Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. | BI01010001010000000000000515BI0100001315 | 29.2 | Cum |
205 | 57.02 | b)Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. | BI01010001010000000000000515BI0100001316 | 19.47 | Cum |
206 | 57.03 | c)Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. | BI01010001010000000000000515BI0100001317 | 33 | Cum |
207 | 57.04 | d)Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001318 | 4.38 | Cum |
208 | 57.05 | e)Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001319 | 2.05 | Cum |
209 | 57.06 | f)Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001320 | 2.07 | Qntl |
210 | 57.07 | g)Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001321 | ||
211 | 57.08 | i)RCC floor, roof slab chhaja up to 4.430 m height | BI01010001010000000000000515BI0100001322 | 12.89 | Sqm |
212 | 57.09 | h)Supplying all materials.labour.T&P and providing brick work in foundation and plinth with 23cmx11cmx8cm size CB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar ( 1:3 ) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001323 | 15.84 | Cum |
213 | 57.1 | i)Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001324 | 34.76 | Sqm |
214 | 57.11 | j)Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:6) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001325 | 56.82 | Sqm |
215 | 57.12 | k)Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001326 | 35 | Sqm |
216 | 57.13 | l)Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification. | BI01010001010000000000000515BI0100001327 | 10 | Each |
217 | 57.14 | m)Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge. | BI01010001010000000000000515BI0100001328 | 2 | Each |
218 | 57.15 | n)Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001329 | 5.84 | Cum |
219 | 58 | Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories | BI01010001010000000000000515BI0100001330 | ||
220 | 58.01 | 1)Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only | BI01010001010000000000000515BI0100001331 | ||
221 | 58.02 | a)Drilling of 200mm dia bore | BI01010001010000000000000515BI0100001332 | ||
222 | 58.03 | i)00 mtr to 30mtr | BI01010001010000000000000515BI0100001333 | 30 | mtr |
223 | 58.04 | ii)30 mtr to 45mtr | BI01010001010000000000000515BI0100001334 | 15 | mtr |
224 | 58.05 | b)Drilling of 150mm dia bore | BI01010001010000000000000515BI0100001335 | ||
225 | 58.06 | i)45 mtr to 215.00mtr | BI01010001010000000000000515BI0100001336 | 200 | mtr |
226 | 58.07 | 2)Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. | BI01010001010000000000000515BI0100001337 | ||
227 | 58.08 | a)Lowering of 200mm dia P.V.C casing pipes | BI01010001010000000000000515BI0100001338 | ||
228 | 58.09 | i)00 mtr to 30 mtrs | BI01010001010000000000000515BI0100001339 | 30 | mtr |
229 | 58.1 | ii)30 mtr to 60mtr | BI01010001010000000000000515BI0100001340 | 15 | mtr |
230 | 58.11 | 3)Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. | BI01010001010000000000000515BI0100001341 | ||
231 | 58.12 | i)200mm dia PVC (sch-80) pipe | BI01010001010000000000000515BI0100001342 | 45 | mtr |
232 | 58.13 | 4)Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) | BI01010001010000000000000515BI0100001343 | 1 | Each |
233 | 58.14 | 5)Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge | BI01010001010000000000000515BI0100001344 | ||
234 | 58.15 | i)By DTH Rig | BI01010001010000000000000515BI0100001345 | 1 | Each |
235 | 58.16 | 6)Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: | BI01010001010000000000000515BI0100001346 | ||
236 | 58.17 | i)Rocky terrain with boulder formation for 300m depth | BI01010001010000000000000515BI0100001347 | 2 | Each site |
237 | 58.18 | 7)Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) | BI01010001010000000000000515BI0100001348 | ||
238 | 58.19 | a)1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) | BI01010001010000000000000515BI0100001349 | 1 | Each |
239 | 58.2 | b)DOL Control panel | BI01010001010000000000000515BI0100001350 | 1 | Each |
240 | 58.21 | c)40mm dia steel short piece | BI01010001010000000000000515BI0100001351 | 1 | Each |
241 | 58.22 | d)Well cap | BI01010001010000000000000515BI0100001352 | 1 | Each |
242 | 58.23 | e)50mm size CI bracket | BI01010001010000000000000515BI0100001353 | 1 | Pair |
243 | 58.24 | f)2.50sqmm flat cable | BI01010001010000000000000515BI0100001354 | 100 | Mtr |
244 | 58.25 | g)20mm dia rigid UPVC pipes | BI01010001010000000000000515BI0100001355 | 45 | Mtr |
245 | 58.26 | i)Steel rope with cover | BI01010001010000000000000515BI0100001356 | 45 | Mtr |
246 | 58.27 | j)Labour charges for lowering including transportation | BI01010001010000000000000515BI0100001357 | 1 | Each |
247 | 58.28 | 8)Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001358 | ||
248 | 58.29 | i)32mm HDPE pipes (Finolex/Supreme make) | BI01010001010000000000000515BI0100001359 | 90 | mtr |
249 | 59 | Rain Water Harvesting System | BI01010001010000000000000515BI0100001360 | ||
250 | 59.01 | 1)Supplying all materials, labour, T&P and fitting and fixing U-PVC, SWR soil waste ventilating pipes and fitting of the following outside diameter conforming to 13592/1992 to walls with nails bobbins and wooden plugs or laying in trenches including with supply of approved rubber lubricant by non-heat application method as per manufactures specification testing earth work in excavation in all kinds of soil and refilling of trenches all complete as per specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001361 | ||
251 | 59.02 | i)110mm U-PVC SWR Pipe | BI01010001010000000000000515BI0100001362 | 31.47 | Mtr. |
252 | 59.03 | ii)110mm U-PVC Plain bend (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001363 | 4 | Each |
253 | 59.04 | iii)110mm U-PVC Socket (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001364 | 6 | Each |
254 | 59.05 | iv)125mm CP grating | BI01010001010000000000000515BI0100001365 | 2 | Each |
255 | 59.06 | 2)Supplying all materials labor T&P and binding glazed stone ware pipes and aligning to requisite gradient inside the trench to jointing with tarred cascade and cement motor prop.(1:1 )encasing the pipe all around with CC(1:3:6) with washed gravel CC(1:4:8) with hard stone metal size 25mm to 50mm on bed on the trench lowering the pipe to bed on trenches in earth work in excavation trenches in all kinds of soil and refilling the same in 30mm layers watering ramming and removal of surplus earth disorient sewer line including use of T&P sight rails binding rods plug lights etc .all complete as per P.H .Specification. All round concrete encasing up to 1.50metre depth. | BI01010001010000000000000515BI0100001366 | ||
256 | 59.07 | i)160mm dia P.V.C. | BI01010001010000000000000515BI0100001367 | 32 | Mtr. |
257 | 59.08 | 3)Supplying all materials labour T&P and constructing 1.80m dia x 2.60 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. | BI01010001010000000000000515BI0100001368 | 2 | Each |
258 | 59.09 | 4)Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001369 | ||
259 | 59.1 | i)Inside size 76cmx76cmx46cm with 18” dia RCC MH cover | BI01010001010000000000000515BI0100001370 | 2 | Each |
260 | 60 | 1st Floor only over the Existing G.F of U.G.C. Hostel | BI01010001010000000000000515BI0100001371 | ||
261 | 60.01 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC pipes, confirming to ASTM - D - 1785 . 89 (sch 80) and pipe fitting of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001372 | ||
262 | 60.02 | A)First floor | BI01010001010000000000000515BI0100001373 | ||
263 | 60.03 | i)20mm dia PVC Pipe | BI01010001010000000000000515BI0100001374 | 40 | Mtrs. |
264 | 60.04 | ii)25mm dia PVC Pipe | BI01010001010000000000000515BI0100001375 | 20 | Mtrs. |
265 | 60.05 | iii)32mm dia PVC Pipe | BI01010001010000000000000515BI0100001376 | 30 | Mtrs. |
266 | 60.06 | B)On Roof fo First Floor | BI01010001010000000000000515BI0100001377 | ||
267 | 60.07 | i)32mm dia PVC Pipe | BI01010001010000000000000515BI0100001378 | 80 | Mtrs. |
268 | 60.08 | ii)40mm dia PVC Pipe | BI01010001010000000000000515BI0100001379 | 40 | Mtrs. |
269 | 61 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001380 | ||
270 | 61.01 | i)15mm dia CP angle stop cock (Jaquar)CON-CHR-059KN | BI01010001010000000000000515BI0100001381 | 12 | Each |
271 | 61.02 | ii)15mm dia CP long body bib cock (Jaquar Make)CON-107KN | BI01010001010000000000000515BI0100001382 | 6 | Each |
272 | 61.03 | iii)15mm dia CP two way bib cock (Jaquar)CON-041KN | BI01010001010000000000000515BI0100001383 | 6 | Each |
273 | 61.04 | iv)15mm dia CP short body bib cock (Jaquar)CON-CHR-047KN | BI01010001010000000000000515BI0100001384 | 6 | Each |
274 | 61.05 | v)20mm dia CP concealed stop cock (Jaquar Make)CON-089KN | BI01010001010000000000000515BI0100001385 | 6 | Each |
275 | 61.06 | vi)25mm dia brass full way valve (Shakti make) | BI01010001010000000000000515BI0100001386 | 6 | Each |
276 | 61.07 | vii)32mm dia brass full way valve (Shakti make) | BI01010001010000000000000515BI0100001387 | 10 | Each |
277 | 61.08 | viii)40mm dia brass full way valve (Shakti make) | BI01010001010000000000000515BI0100001388 | 5 | Each |
278 | 61.09 | ix)25mm dia CP Health Faucet (Jaquar Make)ALD - CHR - 565 | BI01010001010000000000000515BI0100001389 | 6 | Each |
279 | 61.1 | x)125mm CP grating | BI01010001010000000000000515BI0100001390 | 18 | Each |
280 | 61.11 | xi)15mm CP Extension piece | BI01010001010000000000000515BI0100001391 | 36 | Each |
281 | 61.12 | xii)15mm size C.P. flange | BI01010001010000000000000515BI0100001392 | 36 | Each |
282 | 62 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001393 | ||
283 | 62.01 | i)2000 liters capacity PVC water storage tank roof of 1st floor | BI01010001010000000000000515BI0100001394 | 8 | Each |
284 | 63 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001395 | ||
285 | 63.01 | i)Ground floor | BI01010001010000000000000515BI0100001396 | 12 | Each |
286 | 63.02 | ii)First Floor | BI01010001010000000000000515BI0100001397 | 10 | Each |
287 | 64 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001398 | ||
288 | 64.01 | i)Ground floor | BI01010001010000000000000515BI0100001399 | 6 | Each |
289 | 64.02 | ii)First Floor | BI01010001010000000000000515BI0100001400 | 4 | Each |
290 | 65 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001401 | ||
291 | 65.01 | i)Ground floor | BI01010001010000000000000515BI0100001402 | 40 | Mtr |
292 | 65.02 | ii)First Floor | BI01010001010000000000000515BI0100001403 | 30 | Mtr |
293 | 66 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001404 | ||
294 | 66.01 | i)110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) | BI01010001010000000000000515BI0100001405 | 120 | Mtr. |
295 | 66.02 | ii)110mm U-PVC ‘P’ Trap (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001406 | 10 | Each |
296 | 66.03 | iii)110mm U-PVC door bend (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001407 | 10 | Each |
297 | 66.04 | iv)110mm U-PVC Plain bend (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001408 | 10 | Each |
298 | 66.05 | v)110mm U-PVC offset without ear (Ori Plast / Finolex / Supreme Make) | BI01010001010000000000000515BI0100001409 | 16 | Each |
299 | 66.06 | vi)110mm U-PVC Cowl (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001410 | 4 | Each |
300 | 66.07 | vii)110mm U-PVC Plain tee (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001411 | 12 | Each |
301 | 66.08 | viii)110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001412 | 12 | Each |
302 | 66.09 | ix)110mm U-PVC Plain shoe bend (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001413 | 6 | Each |
303 | 66.1 | x)110mm U-PVC Door cross tee | BI01010001010000000000000515BI0100001414 | 4 | Each |
304 | 66.11 | xi)110mm U-PVC Socket (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001415 | 40 | Each |
305 | 67 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001416 | ||
306 | 67.01 | i)580mm size Orissa pan (Hindware/Parryware/Neycer make) | BI01010001010000000000000515BI0100001417 | 4 | Each |
307 | 68 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001418 | ||
308 | 68.01 | i)10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) | BI01010001010000000000000515BI0100001419 | 6 | Each |
309 | 69 | Supplying all materials,labour,T&P and fitting and fixing vitrous Chaina washed down water Closet (European type water closet - EWC) with integral "P" or "S" type trap to the floor including wodden plug and chromoum plated screw including jointing the trap with soil pipe in CM(1:1) fixing plastic seat cover for washed down water closet with crmium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001420 | ||
310 | 69.01 | i)European Water Clost "S" trap(Parryware white) | BI01010001010000000000000515BI0100001421 | 2 | Each |
311 | 70 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001422 | ||
312 | 70.01 | i)Counter top basin | BI01010001010000000000000515BI0100001423 | 6 | Each |
313 | 71 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001424 | ||
314 | 71.01 | i)Towel ring CAN - BCH - 1121 | BI01010001010000000000000515BI0100001425 | 12 | Each |
315 | 72 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. | BI01010001010000000000000515BI0100001426 | ||
316 | 72.01 | i)Large Size mirror with Frame (6x0.90x0.90)= 4.86 | BI01010001010000000000000515BI0100001427 | 4.86 | Sqm |
317 | 73 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001428 | ||
318 | 73.01 | i)CP soap holder (Jaquar)CAN - MCH - 1131N | BI01010001010000000000000515BI0100001429 | 12 | Each |
319 | 74 | Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge. | BI01010001010000000000000515BI0100001430 | ||
320 | 74.01 | i)½” x 5” CP Shower (Plaza Deluxe Make) | BI01010001010000000000000515BI0100001431 | 6 | Each |
321 | 75 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001432 | 12 | Each |
322 | 76 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001433 | 6 | Each |
323 | 77 | Supplying all materials, labour, T&P and constructing Inspection Chamber of inside size 760mm x 760mm x 460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001434 | ||
324 | 77.01 | i)Inside size 76cmx76cmx46cm with 18” dia RCC MH cover | BI01010001010000000000000515BI0100001435 | 4 | Each |
325 | 78 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001436 | 4 | Each |
326 | 79 | Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site. | BI01010001010000000000000515BI0100001437 | 9.16 | Cum |
327 | 80 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001438 | ||
328 | 80.01 | i)First Floor | BI01010001010000000000000515BI0100001439 | 3.77 | Cum |
329 | 81 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001440 | ||
330 | 81.01 | i)first floor | BI01010001010000000000000515BI0100001441 | 4.97 | Cum |
331 | 82 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001442 | ||
332 | 82.01 | i)first floor | BI01010001010000000000000515BI0100001443 | 53.9 | Sqm |
333 | 83 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) (1 cement : 1 sand) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge (ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed series to be pre-approved by the Engineer-in-charge) | BI01010001010000000000000515BI0100001444 | ||
334 | 83.01 | a)Kajaria tile 40cmx40cm (ground floor ) | BI01010001010000000000000515BI0100001445 | ||
335 | 83.02 | i)first floor | BI01010001010000000000000515BI0100001446 | 53.9 | Sqm |
336 | 84 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster (1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001447 | ||
337 | 84.01 | i)First Floor | BI01010001010000000000000515BI0100001448 | 52.94 | Sqm |
338 | 85 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge ) | BI01010001010000000000000515BI0100001449 | ||
339 | 85.01 | a)Kajaria tile 40cmx25cm | BI01010001010000000000000515BI0100001450 | ||
340 | 85.02 | i)First Floor | BI01010001010000000000000515BI0100001451 | 52.94 | Sqm |
341 | 86 | Supplying all materials, labour, T&P and providing and fixing in position M.S panelled door double leaved with M.S frame overall size including frame 1980mm Height x 1070mm Width made out of the following materials conforming to relevant Indian Standard specification, Frame: 35x35x6mm MS angle, Shutter stile: Top and bottom rail 25x25x3mm, MS angle door panell: 1.0mm C R sheet panell stiffner covering width of each leaf 19x5mm MS flat - 3nos on each leaf, Hinges size: 100mm - 6nos (3nos on each side) bought out as per ISS, Hold fast: 35x35x6mm, MS angle 175mm length bifurcated at the tip - 3nos on each side, Handle: 19x5mm MS flat fabricated - 4nos, Aldrop: 2nos bought out as per ISS, Tower bolt: 2nos bought out as per ISS, including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001452 | 648 | K.G |
342 | 87 | Supplying all materials, labour,T&P and painting two coats with any approved paint on new steel work as per specification and direction of the Engineer in charge . | BI01010001010000000000000515BI0100001453 | 36.36 | Sqm |
343 | 88 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001454 | ||
344 | 88.01 | i)110mm dia P.V.C. pipe | BI01010001010000000000000515BI0100001455 | 18 | Mtr. |
345 | 88.02 | ii)160mm dia P.V.C. pipe | BI01010001010000000000000515BI0100001456 | 20 | Mtr. |
346 | 89 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. | BI01010001010000000000000515BI0100001457 | ||
347 | 89.01 | i)MH size 0.91m x 0.91x0.91 m with 0.45 m (18” dia RCC Cover) | BI01010001010000000000000515BI0100001458 | 3 | Each |
348 | 90 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. | BI01010001010000000000000515BI0100001459 | ||
349 | 90.01 | i)1.40m dia x 2.00 m deep | BI01010001010000000000000515BI0100001460 | 1 | Each |
350 | 91 | 1 No of 50 Users septic tank | BI01010001010000000000000515BI0100001461 | ||
351 | 91.01 | a)Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. | BI01010001010000000000000515BI0100001462 | 29.2 | Cum |
352 | 91.02 | b)Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. | BI01010001010000000000000515BI0100001463 | 19.47 | Cum |
353 | 91.03 | c)Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. | BI01010001010000000000000515BI0100001464 | 33 | Cum |
354 | 91.04 | d)Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001465 | 4.38 | Cum |
355 | 91.05 | e)Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001466 | 2.05 | Cum |
356 | 91.06 | f)Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001467 | 2.07 | Qntl |
357 | 91.07 | g)Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001468 | ||
358 | 91.08 | i)RCC floor, roof slab chhaja up to 4.430 m height | BI01010001010000000000000515BI0100001469 | 12.89 | Sqm |
359 | 91.09 | h)Supplying all materials.labour.T&P and providing brick work in foundation and plinth with 23cmx11cmx8cm size CB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar ( 1:3 ) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001470 | 15.84 | Cum |
360 | 91.1 | i)Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001471 | 34.76 | Sqm |
361 | 91.11 | j)Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:6) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001472 | 56.02 | Sqm |
362 | 91.12 | k)Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001473 | 35 | Sqm |
363 | 91.13 | l)Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification. | BI01010001010000000000000515BI0100001474 | 10 | Each |
364 | 91.14 | m)Supplying all materials, labour T&P for providing fitting & fixing 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge. | BI01010001010000000000000515BI0100001475 | 2 | Each |
365 | 91.15 | n)Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001476 | 5.84 | Cum |
366 | 92 | Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories | BI01010001010000000000000515BI0100001477 | ||
367 | 92.01 | 1)Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only | BI01010001010000000000000515BI0100001478 | ||
368 | 92.02 | A)Drilling of 200mm dia bore | BI01010001010000000000000515BI0100001479 | ||
369 | 92.03 | i)00 mtr to 30mtr | BI01010001010000000000000515BI0100001480 | 30 | mtr |
370 | 92.04 | ii)30 mtr to 45mtr | BI01010001010000000000000515BI0100001481 | 15 | mtr |
371 | 92.05 | B)Drilling of 150mm dia bore | BI01010001010000000000000515BI0100001482 | ||
372 | 92.06 | i)45 mtr to 215.00mtr | BI01010001010000000000000515BI0100001483 | 200 | mtr |
373 | 92.07 | 2)Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. | BI01010001010000000000000515BI0100001484 | ||
374 | 92.08 | a)Lowering of 200mm dia P.V.C casing pipes | BI01010001010000000000000515BI0100001485 | ||
375 | 92.09 | i)00 mtr to 30 mtrs | BI01010001010000000000000515BI0100001486 | 30 | mtr |
376 | 92.1 | ii)30 mtr to 60mtr | BI01010001010000000000000515BI0100001487 | 15 | mtr |
377 | 92.11 | 3)Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. | BI01010001010000000000000515BI0100001488 | ||
378 | 92.12 | i)200mm dia PVC (sch-80) pipe | BI01010001010000000000000515BI0100001489 | 45 | mtr |
379 | 92.13 | 4)Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) | BI01010001010000000000000515BI0100001490 | 1 | Each |
380 | 92.14 | 5)Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge | BI01010001010000000000000515BI0100001491 | ||
381 | 92.15 | i)By DTH Rig | BI01010001010000000000000515BI0100001492 | 1 | Each |
382 | 92.16 | 6)Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: | BI01010001010000000000000515BI0100001493 | ||
383 | 92.17 | i)Rocky terrain with boulder formation for 300m depth | BI01010001010000000000000515BI0100001494 | 2 | Each site |
384 | 92.18 | 7)Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) | BI01010001010000000000000515BI0100001495 | ||
385 | 92.19 | a)1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby) | BI01010001010000000000000515BI0100001496 | 2 | Each |
386 | 92.2 | b)DOL Control panel | BI01010001010000000000000515BI0100001497 | 2 | Each |
387 | 92.21 | c)40mm dia steel short piece | BI01010001010000000000000515BI0100001498 | 2 | Each |
388 | 92.22 | d)Well cap | BI01010001010000000000000515BI0100001499 | 1 | Each |
389 | 92.23 | e)50mm size CI bracket | BI01010001010000000000000515BI0100001500 | 2 | Pair |
390 | 92.24 | f)2.50sqmm flat cable | BI01010001010000000000000515BI0100001501 | 100 | Mtr |
391 | 92.25 | g)20mm dia rigid UPVC pipes | BI01010001010000000000000515BI0100001502 | 80 | Mtr |
392 | 92.26 | h)Steel rope with cover | BI01010001010000000000000515BI0100001503 | 80 | Mtr |
393 | 92.27 | i)Labour charges for lowering including transportation | BI01010001010000000000000515BI0100001504 | 2 | Each |
394 | 92.28 | 8)Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge | BI01010001010000000000000515BI0100001505 | ||
395 | 92.29 | i)32mm HDPE pipes (Finolex/Supreme make) | BI01010001010000000000000515BI0100001506 | 90 | mtr |
396 | 93 | 1 no 14,000 ltr capacity R.C.C. Under ground sump | BI01010001010000000000000515BI0100001507 | ||
397 | 93.01 | 1)Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. | BI01010001010000000000000515BI0100001508 | 16.93 | Cum |
398 | 93.02 | 2)Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. | BI01010001010000000000000515BI0100001509 | 5.64 | Cum |
399 | 93.03 | 3)Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. | BI01010001010000000000000515BI0100001510 | 3.08 | Cum |
400 | 93.04 | 4)Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001511 | 1.69 | Cum |
401 | 93.05 | 5)Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001512 | 5.11 | Cum |
402 | 93.06 | 6)Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001513 | 4.52 | Qntl |
403 | 93.07 | 7)Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001514 | ||
404 | 93.08 | 1)RCC floor, roof slab chhaja up to 4.430 m height | BI01010001010000000000000515BI0100001515 | 55.94 | Sqm |
405 | 93.09 | 8)Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001516 | 37.58 | Sqm |
406 | 93.1 | 9)Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001517 | 30.24 | Sqm |
407 | 93.11 | 10)Supplying all materials labour T&P filling sand in foundation and plinth with well watered and rammed etc. all complate. As per direction of | BI01010001010000000000000515BI0100001518 | 1.69 | Cum |
408 | 94 | Rain Water Harvesting System | BI01010001010000000000000515BI0100001519 | ||
409 | 94.01 | 1)Supplying all materials, labour, T&P and fitting and fixing U-PVC, SWR soil waste ventilating pipes and fitting of the following outside diameter conforming to 13592/1992 to walls with nails bobbins and wooden plugs or laying in trenches including with supply of approved rubber lubricant by non-heat application method as per manufactures specification testing earth work in excavation in all kinds of soil and refilling of trenches all complete as per specification and direction of the Engineer in charge. | BI01010001010000000000000515BI0100001520 | ||
410 | 94.02 | i)110mm U-PVC SWR Pipe | BI01010001010000000000000515BI0100001521 | 31.47 | Mtr. |
411 | 94.03 | ii)110mm U-PVC Plain bend (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001522 | 4 | Each |
412 | 94.04 | iii)110mm U-PVC Socket (Ori Plast/Finolex/Supreme Make) | BI01010001010000000000000515BI0100001523 | 6 | Each |
413 | 94.05 | iv)125mm CP grating | BI01010001010000000000000515BI0100001524 | 2 | Each |
414 | 94.06 | 2)Supplying all materials labor T&P and binding glazed stone ware pipes and aligning to requisite gradient inside the trench to jointing with tarred cascade and cement motor prop.(1:1 )encasing the pipe all around with CC(1:3:6) with washed gravel CC(1:4:8) with hard stone metal size 25mm to 50mm on bed on the trench lowering the pipe to bed on trenches in earth work in excavation trenches in all kinds of soil and refilling the same in 30mm layers watering ramming and removal of surplus earth disorient sewer line including use of T&P sight rails binding rods plug lights etc .all complete as per P.H .Specification. All round concrete encasing up to 1.50metre depth. | BI01010001010000000000000515BI0100001525 | ||
415 | 94.07 | i)160mm dia P.V.C. | BI01010001010000000000000515BI0100001526 | 32 | Mtr. |
416 | 94.08 | 3)Supplying all materials labour T&P and constructing 1.80m dia x 2.60 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. | BI01010001010000000000000515BI0100001527 | 2 | Each |
417 | 94.09 | 4)Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge | BI01010001010000000000000515BI0100001528 | ||
418 | 94.1 | i)Inside size 76cmx76cmx46cm with 18” dia RCC MH cover | BI01010001010000000000000515BI0100001529 | 2 | Each |
419 | 95 | E.I. WORKS (PART-III) | BI01010001010000000000000515BI0100001530 | ||
420 | 95.01 | PART - A | BI01010001010000000000000515BI0100001531 | ||
421 | 95.02 | Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit with 5A ,25 on MS box having front bakelite cover of suitable size, MS box with1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Finolex/L&T/Anchor/Havells/V-Guard/ Great White/HPL/ Rhino/ KEI) \n | BI01010001010000000000000515BI0100001532 | ||
422 | 95.03 | a)Group-A -L.P- F.P- C.B.P- | BI01010001010000000000000515BI0100001533 | 60 | Point |
423 | 95.04 | b)Group-B L.P- F.P- C.B.P- | BI01010001010000000000000515BI0100001534 | 250 | Point |
424 | 95.05 | c)Group-C L.P- F.P- C.B.P- | BI01010001010000000000000515BI0100001535 | 35 | Point |
425 | 96 | Supplying and fixing of following modular type switch/socket on the existing switch box/cover including connection etc. as required | BI01010001010000000000000515BI0100001536 | ||
426 | 96.01 | a)5 / 6 Amp switch | BI01010001010000000000000515BI0100001537 | 51 | Each |
427 | 96.02 | b)3 pin 5 / 6 Amp socket outlet | BI01010001010000000000000515BI0100001538 | 51 | Each |
428 | 96.03 | c)15 / 16 Amp switch | BI01010001010000000000000515BI0100001539 | 6 | Each |
429 | 96.04 | d)6 pin 15/16 Amp socket outlet | BI01010001010000000000000515BI0100001540 | 6 | Each |
430 | 97 | Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire -Finolex/L&T/Anchor/Havells/V-Guard/Great White/Mescab/HPL)\n | BI01010001010000000000000515BI0100001541 | ||
431 | 97.01 | a)2 x 1.5 sq.mm + 1 x 1.5sq.mm | BI01010001010000000000000515BI0100001542 | 800 | Mtr |
432 | 97.02 | b)2 X 2.5sq.mm +1 X 1.5sqmm | BI01010001010000000000000515BI0100001543 | 679 | Mtr. |
433 | 97.03 | c)2 X 4sq.mm +1 X 1.5sqmm. | BI01010001010000000000000515BI0100001544 | 400 | Mtr. |
434 | 97.04 | d)2 X 10 sq.mm + 1 X 4 sq.mm -d0- | BI01010001010000000000000515BI0100001545 | 350 | Mtr. |
435 | 98 | S/F of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose . | BI01010001010000000000000515BI0100001546 | 9 | Each |
436 | 99 | Supply and fixing Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required \n\n | BI01010001010000000000000515BI0100001547 | 4 | Each |
437 | 100 | Providing and fixing of 8S.W.G(4 mm) dia copper wire in surface or in recess for loop earthing along with existing surface/ recessed conduit/sub-main wiring/ cable as required. | BI01010001010000000000000515BI0100001548 | 400 | Mtr |
438 | 101 | Earthing with copper earth plate 600mm x 6oomm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having locking arrangement and watering pipe etc(without charcoal and salt) as required. | BI01010001010000000000000515BI0100001549 | 4 | no. |
439 | 102 | Providing and fixing of 25mm x 5mm copper srtip in 40 mm dia G.I pipe from earth electrode. | BI01010001010000000000000515BI0100001550 | 32 | mtr |
440 | 103 | Extra for using salt and charcoal for G.I or copper pipe earth electrode as required. | BI01010001010000000000000515BI0100001551 | 40 | kg |
441 | 104 | Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) make-HPL/ Havells/ Legrand /L&T/C&S.) | BI01010001010000000000000515BI0100001552 | ||
442 | 104.01 | a)12way, Single door | BI01010001010000000000000515BI0100001553 | 2 | Each |
443 | 104.02 | b)8 WAY, SINGLE DOOR | BI01010001010000000000000515BI0100001554 | 3 | Each |
444 | 105 | Supply and fixing of 5Amp to 32A rating 240V "B" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (make-HPL/ Havells/ Legrand /L&T/C&S) | BI01010001010000000000000515BI0100001555 | ||
445 | 105.01 | a)Single pole (SP) | BI01010001010000000000000515BI0100001556 | 48 | Each |
446 | 106 | Istallation, testing and commissioning of pre- wired fluorescent fitting/ compact fluorescent fitting of all sizes complete with all accessories and tube etc, directly as ceiling wall, including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. | BI01010001010000000000000515BI0100001557 | 224 | Each |
447 | 107 | 1' X 20watt LED T-5 fitting( Make-Bajaj/ Philips /Crompton) | BI01010001010000000000000515BI0100001558 | 224 | Each |
448 | 108 | Istallation, testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30cm) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as required. | BI01010001010000000000000515BI0100001559 | 106 | Each |
449 | 109 | Supply and fixing of 48"fan 5 star rated (make-Crompton Greaves High Speed model/Polycab(Vital) or equivalent make \n | BI01010001010000000000000515BI0100001560 | 106 | Each |
450 | 110 | Supply and fixing of fan regulator(Cona/ Anchor/ Usha/Bajaj)\n | BI01010001010000000000000515BI0100001561 | ||
451 | 110.01 | a)Electronics step type | BI01010001010000000000000515BI0100001562 | 106 | Each |
452 | 110.02 | b)Analysis of AC and Gyeser Point | BI01010001010000000000000515BI0100001563 | 6 | Each |
453 | 111 | Fixing charges Exhaust fan with making of hole on wall and all arrangement and connections | BI01010001010000000000000515BI0100001564 | 13 | Each |
454 | 112 | Supply of 300 mm Exhaust fan 900rpm size make-( Crompton/Havels/Usha) | BI01010001010000000000000515BI0100001565 | 13 | Each |
455 | 113 | S/F of200A TPN main switch(Anchor/HPL/L&T) | BI01010001010000000000000515BI0100001566 | 2 | Each |
456 | 114 | S/F of200A TPN Bus-bar- 350 X 32 X 6 mm size(Anchor/HPL/L&T) | BI01010001010000000000000515BI0100001567 | 2 | Each |
457 | 115 | S/F of 10 W LED bulb(Make-Havells /Philips/Bajaj/PAC) | BI01010001010000000000000515BI0100001568 | 9 | Each |
458 | 116 | S/F of 63A TPN main switch(make-Havels/Phillips/Bajaj) | BI01010001010000000000000515BI0100001569 | 2 | Each |
459 | 117 | S/F of 63A TPN Bus- bar (make-Havels/Phillips/Bajaj) | BI01010001010000000000000515BI0100001570 | 2 | Each |
460 | 118 | S/F of computer board consistng of 3 nos 5A and 1 no. 5A switch and socket. | BI01010001010000000000000515BI0100001571 | 64 | Each |
461 | 119 | S/F of ISI marked portable fire extinguisher 4.5 kg Co2 type fire extinguisher comlpete in all respect including initial fill and wall suspension brackets and shall conform to latest IS 15683. | BI01010001010000000000000515BI0100001572 | 6 | Each |
462 | 120 | Supply of 6 kg ABC(POWDER TYPE) Fire extinguisher in HP Steel cylinder ISI marked fitted with pressure indicating gauge, internal tube,squeeze level type valve fully chaeged with ABC powder(Mono Ammonium phosphate) pressure by Nitrogen complete in all respect including wall suspension bracket and conforming to IS :15683 | BI01010001010000000000000515BI0100001573 | 4 | Each |
463 | 121 | Supply and installing at approved location make fire bucket of 24 gauge galvanised steel sheet, painted with inside and black on the button, inscribed with letters" FIRE" in black and gold with dry, clean sand. The scope shall also include the stand for mounting the sand bucket. | BI01010001010000000000000515BI0100001574 | 1 | set |
464 | 122 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 mmsq but not exceeding 120 mmsq on surface as required | BI01010001010000000000000515BI0100001575 | 350 | mtr |
465 | 123 | Supply and making end termination with brass compression gland and aluminium logs for following size of PVC insulated and PVC sheathed / XLPE aluminium cable of 1.1kv grade (without cost of cable ) as required. | BI01010001010000000000000515BI0100001576 | ||
466 | 123.01 | a)25 sq.mm x 3 1/2 core cable | BI01010001010000000000000515BI0100001577 | 8 | set. |
467 | 123.02 | b)3 1/2 X 50sqmm | BI01010001010000000000000515BI0100001578 | 8 | Set |
468 | 124 | S/F of 25 sq.mm x 3 1/2 core alu.armed cable(KEI/Mescab/ Polycab) | BI01010001010000000000000515BI0100001579 | 350 | mtr |
469 | 125 | 3 1/2 X 50sqmm | BI01010001010000000000000515BI0100001580 | 150 | mtr |
470 | 126 | S/F of 415 Amp Panel Distribution Board for 3 Phase Supply (48×60×12) Incoming: i)415 Amp ICTPN SFU HRC Fuse 1 No ii) 4 Pole Bus-Bar 500Amp-1 No. Outgoing: i) 200Amp ICTPN SFU HRC Fuse- 2 No, ii) 63 Amp ICTPN SFU-6 No iii) 63Amp ICDP SFU -2 No iv) 200 Amp TPN Changeover v) Volt Meter, Amp Meter, Selector Switch etc. | BI01010001010000000000000515BI0100001581 | 1 | set. |
471 | 127 | Providing and fixing of lightning conductor finial made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate,reavating, sweating, soldering of copper/(100mm)G.I base plate including holes etc. complete as required. providing and fixing 20 mm x 3 mm copper tape on surface wall to H & V run complete in all respect. | BI01010001010000000000000515BI0100001582 | 1 | Set |
472 | 128 | 90 Watt LED Street Light | BI01010001010000000000000515BI0100001583 | 8 | Each |
473 | 129 | PART - B | BI01010001010000000000000515BI0100001584 | ||
474 | 129.01 | Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVC flexible conduit with 5A ,25 on MS box having front bakelite cover of suitable size, MS box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection (Make of wire-Finolex/L&T/Anchor/Havells/V-Guard/ Great White/HPL/ Rhino/ KEI) \n | BI01010001010000000000000515BI0100001585 | ||
475 | 129.02 | a)Group-A -L.P- F.P- C.B.P- | BI01010001010000000000000515BI0100001586 | 20 | Point |
476 | 129.03 | b)Group-B L.P- F.P- C.B.P- | BI01010001010000000000000515BI0100001587 | 65 | Point |
477 | 129.04 | c)Group-C L.P- F.P- C.B.P- | BI01010001010000000000000515BI0100001588 | 16 | Point |
478 | 130 | Recessed wiring to 5A /6Amp socket outlet with 2 X 1.5sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 20mm dia non metallic PVC flexible conduit with piano type switch, Phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1 X 1.5sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc. as required (Make of wire -Finolex/ L&T/ Anchor/ Havells/V-Guard/Great White/HPL) Separate \n | BI01010001010000000000000515BI0100001589 | ||
479 | 130.01 | a)Separate | BI01010001010000000000000515BI0100001590 | 15 | Each |
480 | 131 | Supplying and fixing of following piano type switch/socket on the existing switch box/cover including connection etc. as required | BI01010001010000000000000515BI0100001591 | ||
481 | 131.01 | a)5 / 6 Amp switch | BI01010001010000000000000515BI0100001592 | 16 | Set |
482 | 131.02 | b)3 pin 5 / 6 Amp socket outlet | BI01010001010000000000000515BI0100001593 | 16 | Set |
483 | 132 | Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire -Finolex/L&T/Anchor/Havells/V-Guard/Great White/Mescab/HPL)\n | BI01010001010000000000000515BI0100001594 | ||
484 | 132.01 | a)2 x 1.5 sq.mm + 1 x 1.5sq.mm | BI01010001010000000000000515BI0100001595 | 600 | Mtr |
485 | 132.02 | b)2 X 2.5sq.mm +1 X 1.5sqmm | BI01010001010000000000000515BI0100001596 | 450 | Mtr. |
486 | 132.03 | c)2 X 4sq.mm +1 X 1.5sqmm. | BI01010001010000000000000515BI0100001597 | 460 | Mtr. |
487 | 132.04 | d)4 X 6 sq.mm + 1 X 2.5 sqmm. | BI01010001010000000000000515BI0100001598 | 240 | Mtr. |
488 | 133 | S/F of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose . | BI01010001010000000000000515BI0100001599 | 30 | Each |
489 | 134 | Supply and fixing Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required \n\n | BI01010001010000000000000515BI0100001600 | 2 | Each |
490 | 135 | Providing and fixing of 8S.W.G(4 mm) dia copper wire in surface or in recess for loop earthing along with existing surface/ recessed conduit/sub-main wiring/ cable as required. | BI01010001010000000000000515BI0100001601 | 100 | Mtr |
491 | 136 | Earthing with copper earth plate 600mm x 6oomm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having locking arrangement and watering pipe etc(without charcoal and salt) as required. | BI01010001010000000000000515BI0100001602 | 1 | no. |
492 | 137 | Providing and fixing of 25mm x 5mm copper srtip in 40 mm dia G.I pipe from earth electrode. | BI01010001010000000000000515BI0100001603 | 30 | mtr |
493 | 138 | Extra for using salt and charcoal for G.I or copper pipe earth electrode as required. | BI01010001010000000000000515BI0100001604 | 30 | kg |
494 | 139 | Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) make-HPL/ Havells/ Legrand /L&T/C&S.) | BI01010001010000000000000515BI0100001605 | ||
495 | 139.01 | a)8 WAY, SINGLE DOOR | BI01010001010000000000000515BI0100001606 | 3 | Each |
496 | 140 | Supply and fixing of 5Amp to 32A rating 240V "B" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (make-HPL/ Havells/ Legrand /L&T/C&S) | BI01010001010000000000000515BI0100001607 | ||
497 | 140.01 | a)Single pole (SP) | BI01010001010000000000000515BI0100001608 | 24 | Each |
498 | 141 | Istallation, testing and commissioning of pre- wired fluorescent fitting/ compact fluorescent fitting of all sizes complete with all accessories and tube etc, directly as ceiling wall, including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. | BI01010001010000000000000515BI0100001609 | 40 | Each |
499 | 142 | 1' X 20watt LED T-5 fitting( Make-Bajaj/ Philips /Crompton) | BI01010001010000000000000515BI0100001610 | 40 | Each |
500 | 143 | Istallation, testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30cm) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as required. | BI01010001010000000000000515BI0100001611 | 26 | Each |
501 | 144 | Supply and fixing of 48"fan 5 star rated (make-Crompton Greaves High Speed model/Polycab(Vital) or equivalent make \n | BI01010001010000000000000515BI0100001612 | 26 | Each |
502 | 145 | Supply and fixing of fan regulator(Cona/ Anchor/ Usha/Bajaj)\n | BI01010001010000000000000515BI0100001613 | ||
503 | 145.01 | a)Electronics step type | BI01010001010000000000000515BI0100001614 | 26 | Each |
504 | 146 | Supply and fixing of piano type switch ISI marked on existing board/cover and connection as required.(Anchor/Cona/Havels, Great White)\n\n | BI01010001010000000000000515BI0100001615 | ||
505 | 146.01 | a)15 Amp switch. | BI01010001010000000000000515BI0100001616 | 2 | Each |
506 | 146.02 | b)15Amp socket. | BI01010001010000000000000515BI0100001617 | 2 | Each |
507 | 147 | Fixing charges Exhaust fan with making of hole on wall and all arrangement and connections | BI01010001010000000000000515BI0100001618 | 8 | Each |
508 | 148 | Supply of 300 mm Exhaust fan 900rpm size make-( Crompton/Havels/Usha) | BI01010001010000000000000515BI0100001619 | 8 | Each |
509 | 149 | S/F of Superior type Ding dong call bell/ buzzer of ISI marked on 6" x 4" conforming to IS-2268/1994 and bell push of ISI marked conforming to IS-1293/1988 (make Cona/Anchor) | BI01010001010000000000000515BI0100001620 | 1 | Each |
510 | 150 | S/F of200A TPN main switch(Anchor/HPL/L&T) | BI01010001010000000000000515BI0100001621 | 1 | Each |
511 | 151 | S/F of200A TPN Bus-bar- 350 X 32 X 6 mm size(Anchor/HPL/L&T) | BI01010001010000000000000515BI0100001622 | 1 | Each |
512 | 152 | S/F of 10 W LED bulb(Make-Havells /Philips/Bajaj/PAC) | BI01010001010000000000000515BI0100001623 | 30 | Each |
513 | 153 | S/F of 63A TPN Bus- bar (make-Havels/Phillips/Bajaj) | BI01010001010000000000000515BI0100001624 | 2 | Each |
514 | 154 | S/F of computer board consistng of 3 nos 5A and 1 no. 5A switch and socket. | BI01010001010000000000000515BI0100001625 | 2 | Each |
515 | 155 | Provision of co2 fire extinguisher ABC powder type 6 kg capacity | BI01010001010000000000000515BI0100001626 | 5 | Each |
516 | 156 | Laying of one no.of PVC insulated and PVC seathed/ XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc as required. | BI01010001010000000000000515BI0100001627 | 180 | mtr |
517 | 157 | 25sq.mm 3 1/2 core PVC armoured Aluminium cables cable ISI marked. | BI01010001010000000000000515BI0100001628 | 8 | Set |
518 | 158 | Supply and making end termination with brass compression gland and aluminium logs for following size of PVC insulated and PVC sheathed / XLPE aluminium cable of 1.1kv grade (without cost of cable ) as required. | BI01010001010000000000000515BI0100001629 | 8 | Mtr |
519 | 159 | Supply of 25sq.mm 3 1/2 core PVC armoured Aluminium cables cable ISI marked. | BI01010001010000000000000515BI0100001630 | 80 | mtr |
520 | 160 | LIGHTNING ARRESTER | BI01010001010000000000000515BI0100001631 | ||
521 | 160.01 | Providing and fixing of lightning conductor finial made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required | BI01010001010000000000000515BI0100001632 | 1 | Each |
522 | 160.02 | Reveting, sweating and soldering of copper / G.I. tape (with another copper / G.I. tape, base, base of the finial or any other metalic object) as required | BI01010001010000000000000515BI0100001633 | 100 | Mtr |
523 | 160.03 | Providing and fixing of copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required(For horizontal run) | BI01010001010000000000000515BI0100001634 | 100 | Mtr |
524 | 160.04 | Providing and fixing of copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required(For vertical run) | BI01010001010000000000000515BI0100001635 | 200 | Mtr |
525 | 160.05 | S/F of 90 W LED Street light(make - Polycab/ Mescab/ Phillips) | BI01010001010000000000000515BI0100001636 | 5 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy