Military Engineer Services-MES has published Repair/Replacement Of Fire Fighting Fire Alarm System At Cgra Kunjathbail Under Age B/R Mangalore Under Ge ( I ) ( Cg ) Goa. Submission Date for this Tender is 21-12-2020. Fire Alarm Systems Tenders in New Mangalore Karnataka Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

26053244
Corrigendum : Repair/Replacement Of Fire Fighting Fire Alarm System At Cgra Kunjathbail Under Age B/R Mangalore Under Ge ( I ) ( Cg ) Goa
Open Tender
Indian
Karnataka
New Mangalore Karnataka
21-12-2020

Tender Details

Repair / Replacement Of Fire Fighting Fire Alarm System At Cgra Kunjathbail Under Age B / R Mangalore Under Ge ( I ) ( Cg ) Goa

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Dec-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-12-2020

Key Value

Document Fees
INR 300 /-
EMD
INR 9700.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIRS/REPLACEMENT OF FIRE FIGHTING, FIRE ALARM SYSTEM AT CGRA KUNJATHBAIL UNDER AGE B/R MANGALORE UNDER GE (I) (CG) GOA
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M & L for refilling fire extinguisher for following type and capacity complete all as specified and directed.
2 1.01 (a) DRY CHEMICAL POWDWE (DCP) type Fire extinguisers : stored pressure - 9 kg capacity 5 Job
3 1.02 (b) CARBON DIOXIDE(CO2) type Fire extinguisers : - 4.5Kg capacity 6 Job
4 1.03 (c) AQUEOUS FILM-FORMING FOAM (AFFF ) type Fire extinguisers : - 9 liters capacity 5 Job
5 2 M & L Painting fire hydrant pipe line up to 100mm dia by scrapping old rusted paint and applying one coat of red oxide primer and two coats of synthetic enamel paint of fire red colour including marking symbol for fire hydrant flow, complete all as specified and directed. 80 RM
6 3 M & L for taking down carefully electric driven monoblock pump 3-phase 415v,50Hz,AC from foundation/ coupling, transporting to civil workshop, opening the motor,Checking the insulation value of the windings, insulating the winding with same class of insulation, painting with one coat of synthetic enamel paint as per colour code and return back to site and re-installing the motor and connecting to the pump, testing the motor for satisfactory performance complete all as specified and directed for the following capacity.
7 3.01 monoblockpump of capacity 12.5HP/9.3 KW 2 Job
8 4 Opening and servicing/overhauling the electric driven monoblock pump and motor 12.5 HP and replacing the defective bearing, greasing replacing the burnout gland rope, studs, nuts, bolts, washers ,air releasing valve ,rubber gasket ,metal filling, turing/ grinding and balancing the shaft etc. and refixing complete all as specified and directed. 4 Job
9 5 S&F Dial type pressure gauge(4"Dia) 0-21 kgs/cm2 including taking down old unserviceable item complete all as specified and directed. 2 Each
10 6 S&F Single pressure switch, universal type to suit the system including taking down old unserviceable item complete all as specified and directed. 2 Each
11 7 S&F gun metal air release valve 25mm dia including taking down old unserviceable item complete all as specified and directed. 4 Each
12 8 M & L with Replacement of Gun metal fire Hydrant valve with 5mm flanged inlet and 63 mm female single instantaneous outlet complete with Lug & Chain as per IS 5290 Hydrostatically tested to 21 Kgf/cm2 of pressure having a flow rate of 900 LPM at 7Kgf/m2 complete all as specified and directed. 3 Each
13 9 M & L with Replacement of Non-perculating flexible fire fighting delivery hose fire hose 63 mm dia confirming to Type A of IS:636, 15 meter length including gunmetal heavy duty pair of male and female couplings complete all as specified and directed. 10 Each
14 10 M & L with Replacement of swiniging hose reel of 20 mm dia wall mounted type comprising rubber hose 30 m long high pressure double braided bearing IS 444, PVC shut off nozzle and 25 mm gunmetal valve conforming to IS 884 and connected to wet raiser complete all as specified and directed. 3 Each
15 11 M & L with Replacement of gunmetal branch pipe with male threaded nozzle of 15mm and male instantaneous inlet of 63 mm dia as per IS : 903 complete all as specified and directed. 4 Each
16 12 S & F in repairs cast iron sluice valve 100mm dia with flanged ends confirming to IS 14846 type PN 1.0 with brass spindle, Cast Iron wheel etc. including all accessories complete all as specified and as directed. 3 Each
17 13 M & L Painting of fire control cabinet out door type size 0.5 x 0.5 x 0.3 meter with two coats of synthetic enamel paint over a coat red oxide primer by spray paint including scrapping out old rusted paint and necessary snickering and making complete all as specified and directed. 12 job
18 14 Repair of microprocesser based fire alarm control panel NOTIFIRE FS 3030, having six loop data card, battery, LCD panel, buzzers required software program etc, including testing complete all as specified and directed.\nNote: The unit rate quoted shall include for regular inspection, /servicing of loop wiring, heat / smoke detectors, response indicator, MCP, sounder cum scob with control module all as directed.\n 2 job
19 15 S & F manual call point resettable type complete all as specified and directed. 10 Each
20 16 S & F addressable electronic sounder cum storb with control module with taking out old unserviceable all as directed by Engineer In Charge. 7 Each
21 17 Excavation in trenches in hard / dense soil n.exc 1.5 m wide and n. exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying pipes complete all as specified and as directed. 5 Cum
22 18 Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of pipes including spreading, levelling, and well ramming complete all as specified and as directed. 3 Cum
23 19 Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed 1 Cum
24 20 Supply and replace rubber bush for pump coupling suitable complete all as specified and directed for the following capacity of pumps
25 20.01 (a)12.5HP/9.3 KW motor 4 Each
26 21 Repairs to CI sluice valves by taking out gland sleeve, check nut spindle, gate etc. and cleaning the valve by removing all scales and reassembling the valve with new packing nut and bolts including painting with one coat of synthetic enamel paint complete all as specified and directed for the following:
27 21.01 Sluice valve flanged type 100/ 80mm dia. 6 Each
28 22 Repairs to CI Non return valves by opening the cover and cleaning the valve by removing all scales, dirt etc and reassembling the valve with new packing nut and bolts including painting with one coat of synthetic enamel paint complete all as specified and directed for the following:
29 22.01 Non return valve flanged type 100/80 mm dia. 3 Each
30 23 M & L our for attending breakdown of 100 mm dia pipe line bursting/cracks including broken pipe pieces of various sizes through gas cutting or manual cutting as required at site and providing new CI/MS/GI pipes of required length (not more than 2m) and removing out the damaged CI pipe and inserting necessary specials such as flanges etc as required at site including testing for the leakages of flange joints for 100mm dia MS/CI pipes complete all as specified and directed.\nNote:Excavation,returning refilling will be measured and paid seperately under relevant item of BOQ. 2 Job
31 24 M & L for replacement of glass panel for indoor fire hydrent boxes as per site requirement by taking down old broken glass complete all as specified and directed. 5 Job
32 25 Supply and laying or fixing to wall in repairs PVC insulated, PVC sheathed copper cable heavy duty 1100 volt grade 4 core of size 4 sqmm complete all as specified and directed. 60 RM
33 26 S & F in repairs multistranded PVC insulated unsheated HRFR copper cable of size 1.5 sqmm complete all as specified and directed. 120 RM
34 27 M & L for testing of all equipment and checking of water pressure by starting pump in auto and mannual as per site requirement once in a month in the presence of Engineer -in-charge complete all as specified and directed.\n(Note: Payment shall be made only after production of Test report duly signed by all concern.) 11 Job
35 28 M & L with Replacement of fire bucket stand each have set of three arrangement complete all as specified and directed. 4 Each
36 29 M & L with Replacement of fire bucket complete all as specified and directed. 12 Each