Completion Of Incomplete Work Against Ca No Ge/C-30/2020-21 Petty E/M Repair Works In The Areas Of Arjan Vihar New Pratap Chowk Shopping Complex Mi Room And Other Adjoining Units Under Ge ( Central ) Delhi Cantt-10 Completion Of Incomplete Work Agains, GE (Central) Delhi Cantt-Delhi

Military Engineer Services-MES has published Completion Of Incomplete Work Against Ca No Ge/C-30/2020-21 Petty E/M Repair Works In The Areas Of Arjan Vihar New Pratap Chowk Shopping Complex Mi Room And Other Adjoining Units Under Ge ( Central ) Delhi Cantt-10 Completion Of Incomplete Work Agains. Submission Date for this Tender is 09-12-2020. Electromechanical Work Tenders in GE (Central) Delhi Cantt Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

26051697
Corrigendum : Completion Of Incomplete Work Against Ca No Ge/C-30/2020-21 Petty E/M Repair Works In The Areas Of Arjan Vihar New Pratap Chowk Shopping Complex Mi Room And Other Adjoining Units Under Ge ( Central ) Delhi Cantt-10 Completion Of Incomplete Work Agains
Open Tender
Indian
Delhi
GE (Central) Delhi Cantt
09-12-2020

Tender Details

Completion Of Incomplete Work Against Ca No Ge/C-30/2020-21 Petty E/M Repair Works In The Areas Of Arjan Vihar New Pratap Chowk Shopping Complex Mi Room And Other Adjoining Units Under Ge ( Central ) Delhi Cantt-10 Completion Of Incomplete Work Against Ca No Ge/C-30/2020-21 Petty E/M Repair Works In The Areas Of Arjan Vihar , New Pratap Chowk Shopping Complex Mi Room And Other Adjoining Units Under Ge ( Central ) Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Dec-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-12-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work : COMPLETION OF INCOMPLETE WORK AGAINST. CA NO GE/C-30/2020-21 PETTY E/M REPAIR WORKS IN THE AREAS OF ARJAN VIHAR, NEW PRATAP CHOWK, SHOPPING COMPLEX, MI ROOM AND OTHER ADJOINING UNITS UNDER GE (CENTRAL) DELHI CANTT-10
Sl. No. Item Code / Make Quantity Units
1 1 Checking electrical points for continuous electric supply system and replacement of unserviceable spares for all electrical fixtures, ceiling/exhaust fans of any size and capacity and carrying out minor repairs, fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work complete on all working days including holidays complete all as specified and directed by Engr-in-charge, at Arjan Vihar area. 6600 Each Complaint
2 2 Attending to complaint of unsv switch ,socket ,fan regulator and making of light / power point in casing caping upto 2 mtr of length and maintenance work complete on all working days including holidays complete all as specified and directed by Engr-in-charge, at Arjan Vihar area. 2640 Each Complaint
3 3 Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable spares, burnt copper wire connections wherever required and repairing any type of switch, socket, plug top etc complete all as specified and directed by Engr-in-charge\n\n 1320 Each Complaint
4 4 Attending to electrical complaint of no light / short circuit in light or power circuit / MCCB tripping or any other emergency nature complaint during night hours (from 2100 to 0500 hrs).\nNotes:- for Item No. 1 to 4\n(a) fixtures / fittings shall be paid under relevant item against supply only.\n(b) Contractors are advised to visit the sites before quoting their rates.\n(c) Materials for repair works as directed by Engineer-in-Charge shall be supplied by the contractor and adequate stock shall dbe held all the time by contractor \n(d) Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. \n(f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours.\n(g) All ser numbered complaint docket will be provided by contractor and amount of docket included in this.\n 990 Each Complaint
5 5 Supply only switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer-in-Charge 200 Each
6 6 Supply only switch piano 6 amp SP two way, Icomplete all as specified and directed by Engineer-in-Charge 15 Each
7 7 Supply only socket piano outlet 6 Amp flush button type complete all as specified and directed by Engineer-in-Charge 150 Each
8 8 Supply only bell push single pole 6 Amps complete all as specified and directed by Engineer-in-Charge 30 Each
9 9 Supply only switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer-in-Charge 150 Each
10 10 Supply only socket piano outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer-in-Charge 150 Each
11 11 Supply only Ceiling fan regulator electronic step switch type/socket type, suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phasecomplete all as specified and directed by Engineer-in-Charge 150 Each
12 12 Supply only switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge. \n 350 Each
13 13 Supply only switch Modular type 6 Amps two way 230V AC complete all as specified and directed by Engineer in charge. \n 10 Each
14 14 Supply only replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. 20 Each
15 15 Supply only Modular socket outlet 5 pin 6 Amp socket 2 moduler complete all as specified and directed by Engineer in charge. \n 150 Each
16 16 Supply only switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in charge.\n 150 Each
17 17 Supply only Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge. 150 Each
18 18 Supply only Modular five stepped type electronic fan regulator 1/2 module 230V AC complete all as specified and directed by Engineer in charge. . 200 Each
19 19 Supply only ceiling rose surface PVC type with three terminals complete all as specified and directed by Engineer-in-Charge 60 Each
20 20 Supply only Electric bell Ding-Dong AC 230 Volt etc complete all as specified and directed by Engineer-in-Charge 30 Each
21 21 Supply only insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer-in-Charge 35 Each
22 22 Supply only industrial metal clad plug top, 3 pin, 10amp / 20 amp complete all as specified and directed by Engineer-in-Charge 30 Each
23 23 Supply only industrial metal clad socket 3 pin 10 amp / 20 amp complete all as specified and directed by Engineer-in-Charge 30 Each
24 24 Supply only relacement plug top 16 Amps 3 pin 230- volts complete all as specified and directed by Engineer-in-Charge 10 Each
25 25 Supply only LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed by Engineer-in-Charge 500 Each
26 26 Supply only LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level =100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed by Engineer-in-Charge . (Mirror light)\n 150 Each
27 27 Supply only LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed by Engineer-in-Charge 200 Each
28 28 Supply only surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level = 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed by Engineer-in-Charge 150 Each
29 29 Supply only in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base.complete all as specified and directed by Engineer-in-Charge 110 Each
30 30 Supply only 14W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz complete all as specified and directed by Engineer-in-Charge 190 Each
31 31 Supply only 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz, complete all as specified and directed by Engineer-in-Charge 200 Each
32 32 Supply only MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer-in-Charge 60 Each
33 33 Supply only MCB DP 20 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer-in-Charge 20 Each
34 34 Supply only MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer-in-Charge 200 Each
35 35 Supply only MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer-in-Charge 50 Each
36 36 Supply only MCCB 250 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer-in-Charge 2 Each
37 37 Supply only MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer-in-Charge 1 Each
38 38 Supply only MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer-in-Charge 1 Each
39 39 Supply only single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB SP 20 Amp complete all as specified and directed by Engineer-in-Charge 30 Each
40 40 Supply only PVC Gang box surface type heavy duty suitable for single switch 5 Amps complete all as specified and directed by Engineer-in-Charge 5 Each
41 41 Supply only Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer-in-Charge 5 Each
42 42 Supply only replacement white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge. 10 Each
43 43 Supply only replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge. 10 Each
44 44 Supply only replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge. 10 Each
45 45 Supply only replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge. 10 Each
46 46 Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :- Make :-As per sample.
47 46.01 Sheet 4" x 4" single cutting suitable for one piano switch 5 Each
48 46.02 Sheet 4" x 4" two cuttings suitable for two piano switches 5 Each
49 46.03 Sheet 4" x 7" three cuttings suitable for three piano switches 5 Each
50 46.04 Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches 5 Each
51 46.05 Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed. 5 Each
52 46.06 Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed. 5 Each
53 47 Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed by Engineer-in-Charge 250 Each
54 48 Supply only replacement of capacitor 2.5 Mfd, 240 V complete all as specified and directed by Engineer-in-Charge 100 Each
55 49 supply only hole fastner madeup of MS 6" long with complete nut bolt complete all as specified and directed by Engineer-in-Charge 40 Each
56 50 supply only hole fastner madeup of MS 4" long with complete nut bolt complete all as specified and directed by Engineer-in-Charge 40 Each
57 51 Supply only heating element of 2 KW any type with nut bolt washer complete all as specified and directed by Engineer-in-Charge 50 Each
58 52 Supply only heating element of 1.5 KW any type with nut bolt washer complete all as specified and directed by Engineer-in-Charge 50 Each
59 53 Supply only non return valve 15mm dia (ISI Marked) for geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting upcomplete all as specified and directed by Engineer-in-Charge 40 Each
60 54 Supply only for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge. 25 Each
61 55 Supply only thermostat for 25/35/50 ltrs capacity of geysers complete all as specified and directed by Engineer-in-Charge 40 Each
62 56 Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed by Engineer-in-Charge Make - Havells / Jaquar / Bajaj. 20 Each
63 57 Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 1.5 sqmm with approved colour code complete all as specified and directed by Engineer-in-Charge 180 RM
64 58 Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 2.5 sqmm with approved coloured code complete all as specified and directed by Engineer-in-Charge 180 RM
65 59 Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 4 sqmm with approved coloured code complete all as specified and directed by Engineer-in-Charge 90 RM
66 60 Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 6 sqmm with approved coloured code complete all as specified and directed by Engineer-in-Charge 90 RM
67 61 Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 10 sqmm with approved coloured code complete all as specified and directed by Engineer-in-Charge 90 RM
68 62 Supply only replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll complete all as specified and directed by Engineer-in-Charge 90 RM
69 63 Taking down sub main wiring off sizes etc complete all as specified and directed by Engineer-in-Charge 300 RM
70 64 Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 4.00 sqmm (Main Cable and neutral) and one run of 4.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection complete all as specified and directed by Engineer-in-Charge 100 RM
71 65 Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 6.00 sqmm (Main Cable and neutral) and one run of 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection complete all as specified and directed by Engineer-in-Charge 100 RM
72 66 Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 10 sqmm (Main Cable and neutral) and one run of 10 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection complete all as specified and directed by Engineer-in-Charge 100 RM
73 67 Note :- Total amount of Sch of credit is Rs12255.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.