Repair And Maintenance Of Lighting Protection Earthing Including Associated Em Works At Hemrl Sutarwadi Under Gerd Pashan Pune, GERD PASHAN PUNE-Maharashtra

Military Engineer Services-MES has published Repair And Maintenance Of Lighting Protection Earthing Including Associated Em Works At Hemrl Sutarwadi Under Gerd Pashan Pune. Submission Date for this Tender is 08-12-2020. Electromechanical Work Tenders in GERD PASHAN PUNE Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

26023718
Repair And Maintenance Of Lighting Protection Earthing Including Associated Em Works At Hemrl Sutarwadi Under Gerd Pashan Pune
National Competitive Bid
Indian
Maharashtra
GERD PASHAN PUNE
08-12-2020

Tender Details

Repair And Maintenance Of Lighting Protection Earthing Including Associated Em Works At Hemrl Sutarwadi Under Gerd Pashan Pune

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : Repair and maintenance of lightning protection, earthing including associated E/M works at HEMRL Sutarwadi under GE(I) R&D Pashan
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SCHEDULE 'A' PART - I \nMaterial and labour for testing of conventional type lightening protection system including earthing around complete building complete all as specified and directed comprising of following : -\n(a) Before testing a visual check to be carried out jointly by the contractor or his authorised rep, Engr-in-Charge and rep of users for the mechanical condition of all conductors, bonds, joints, (b) Testing continuity and resistance of conductors, ohmic resistance of lightning conductor system complete with air termination but without the earth electrode connection and recording results, (c) Testing of each earth electrode point without continuity conductors, air termination and ring conductor, (d) Testing the resistance to earth of the whole installations with all earth electrodes continuity, conductors, air termination and bonding of other services and results are to be recorded, (e) All above testings are to be done in accordance with STEC Pamphlate No. 7 and IS 2309, 1999 (2nd revision) and IS 3043, 1987. The results are to be recorded in a prescribed format duly signed by contractor, Engr-in-Charge and rep of users and to be submitted by contractor in triplicate to Engineer in Charge complete all as specified and directed.\nNotes : (i) The testing mentioned against Srl Nos (b) to (e) here in above will be conducted only after rectifying the defects observed during visual check, (ii) Unit rate quoted is deemed to be inclusive of writing board in white colour letters not exceeding 2 cm height on the black colour back ground on wall such as - Tested on, Due date of testing, E.g. EP No. 1-ER 10 ohms. EP No. should be mentioned on individual earth pits and ER value of installation etc. (iii) Contractor has to arrange necessary testing instruments of suitable range duly latest calibrated (certificates to be produced). (iv) If ohmic resistance value exceeds 1 ohm, the system to be rectified by cleaning with CRC solution, tightening, replacement of bolts, nuts, rivets, etc. to get value below 1 ohm. (v) In case resistance value of earthing exceeding more than 10 ohms, the existing earthing to be replaced and replacement of earthing shall be measured and paid separately under appropirate item here-in-after. (vi) Material and labour for necessary repairs/replacement of unserviceable items will be measured and paid separately under relevant items of sch 'A'/BOQ here in after.The rate quoted is deemed to be include the above provisions. 226 Each Job
2 2 Material and labour in repairs of lightning protection system mounted on top of steel tubular poles / PCC poles / iron structure of any type and height between 15metre to 18metre above ground level including necessary T & P and all arrangment complete all as specified and directed. \nNote : LP system for complete building / magzine / shed / lab will be mesured as one unit.\n 2 Each Job
3 3 Taking down / dismantling existing perished aluminium/GI strip of size 25 mm x 3 mm / 32 mm x 6 mm from any height on roof top / on walls of conventional type lightening protection network system complete all as specified and directed.\n 3750 Running Metre
4 4 Material and labour for aluminium strip of size 25 mm x 3 mm , fixed on PCC block in epoxy based insulator of 35 mm size, distance / interval not more than 1.0 metre, on roof top and down conductor complete all as specified and directed.\n 3200 Running Metre
5 5 Fixing only old serivecable aluminium strip 25mm x3 mm obtainted from taking down, at any height on roof top, on existing insulators any type, on walls complete all as specified and directed.\n 300 Running Metre
6 6 Material and labour GI strip of size 32 mm x 6 mm on walls / buried under ground, on existing insulators any type including jointing the system of conventional type lightening the system of conventional type lightening protection network and making good the disturbed surface of walls complete all as specified and as directed.\n 150 Running Metre
7 7 Fixing oly old serviceable GI strip of size 32 mm x 6 mm obtained from taking down burried in ground or fixed on wall with suitable 35 mm size epoxy base insulators or in floors, fixed at distance / interval of not more than 1.0 metre and connected to test point including necessary bending, jointing at test points with 2 Nos GI nuts, bolts, lead washers, jointing strips at all joints complete all as specified and directed. 100 Running Metre
8 8 Supply and fixing in repairs epoxy base insulator of suitable size, 35mm height fixed on PCC blocks/ wall or mild steel angle/ Pipe or on traverse etc. complete all as specified and directed.\n 2600 Each
9 9 Material and labour in repairs for PCC block of size 150mm x 150mm x 150mm in PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate including necessary form work, mould for fair and even surfaces, etc., and removal old PCC block complete all as specified and directed.\n 2500 Each
10 10 Supply and fixing in repairs inspection box / cover box of size 250 mm x 150 mm x 100 mm, made of 2 mm thick mild steel sheet with side hinged front opening cover including provision of 2 Nos epoxy insulators and insulating PVC sheathed for incoming and outgoing, aluminium / GI strips for proper insulation, etc. including removal of old inspection box of any shape and size complete all as specified and directed.\n 75 Each
11 11 Supply and fixing in repairs air termination single pointed aluminium rod of 12 mm dia 300 mm long fixed to aluminium strip 25 mm x 3 mm including drilling holes, nuts, bolts, washers for resting/ supporting of air terminals etc. and removal old complete all as specified and directed.\n 200 Each
12 12 Fixing only in repairs old serviceable air termiantion complete including making good the disturbed surfaces including provision of insulator, strip and connect to aluminium strip including 2 Nos drilling holes, nuts, bolts, washers complete all as specified and directed.\n 100 Each
13 13 Material and labour in repairs for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground earth pit not less than 2.25 metre deep below ground level with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanised strip 32 mm x 6 mm by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No. 03 of SSR Part I connected to earthing test point including excavation and earth work in hard / dense soil, GI pipe for watering light grade 20 mm bore and GI funnel and wire mesh, PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate ) in chamber including necessary formwork / mould for fair and even surfaces, precast RCC 1:2:4 type B0 (using 12 mm graded crushed stone aggregate ) cover slab, protection pipe 40 mm bore GI pipe light grade for earth lead upto 7.50 metre long, salt & charcoal including testing complete all as specified and directed.\n 21 Each
14 14 Material and labour in repairs for earthing with copper earthplate electrode 600mm x 600mm x 3.15 mm thick burried directly in ground earth pit not less than 2.25 metre deep below ground level with top edge of the plate not less than 1.5 metre below normal ground level connected to copper strip 20 mm x 3 mm by means of nuts, bolts, checknuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of SSR part-I connected to earthing test point including excavation and earth work in any type of soil, PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) earth pit including necessary formwork, mould for fair surfaces including precast RCC cover slab (1: 2 : 4) type B0,(using 12.5 mm graded crushed stone aggregate ), GI protection pipe light grade 25 mm bore, watering pipe GI light grade 20 mm bore with funnel & wire mesh, charcoal & salt complete all as specified and directed.\nNotes for item Nos 13&14 : Test report shall be prepared and submitted by the contractor in triplicate duly signed by contractor, Engineer in charge, JE and PMG / user. Test results are to be written in letters of 20mm height in white colour on black paint back ground. Copper strip required beyond 7.5 metre will be measured and paid sepeartely.\n 5 Each
15 15 Material and labour in repairs for special factory made earthing electrode comprising of Hot dipped galvanized MS flat inserted in to GI pipe of 88 mm bore (outer), 3 metre length, filled with non magnetic anti corrosive material specially developed for ground resistance enhancement power around the electrode to retain moisture conforming to IS 3043 including necessary boring in ground of 150 mm dia in hard / dense soil connecting to test point including excavation / earth work in hard / dense soil, PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate ) chamber including necessary formwork, mould for fair and even surfaces, RCC 1:2:4 type B0 ( using 12.5 mm graded crushed stone aggregate) precast cover slab, GI strip 32 mm x 6 mm upto 7.5metre as directed, connecting to test point and removal old complete all as specified and directed. Notes : The earth resistance shall be less than 3 Ohms. Contractor shall improve the earthing resistance within the permissible limit without any extra cost. Strip beyond 7.5 metre will be measured and paid for sepeartely.\n 12 Each
16 16 Material and labour in repairs PCC Earth pit in PCC 1 : 2 : 4 type B1 ( using 20 mm graded crushed stone aggregate ) including precast PCC 1 : 2 : 4 type B0 (using 12.5 mm graded crushed stone aggregate ) as in pit cover, GI funnel with wire mesh and removal old complete all as specified and directed.\n\n 50 Each Job
17 17 Taking down copper / aluminium point wiring any type (light, fan, socket or power) complete including switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors, etc. complete all as specified and directed. 345 Per Point
18 18 Taking down carefully by unscrewing fittings and fixtures such as tube light fitting / security light fitting any type wall monted, ceiling mounted, recess mounted etc. and carrying to store for reuse old serviceable light fitting or taking credit of un serviceable fittings complete all as specified and directed. 167 Each
19 19 Material and labour for point wiring with 1.5 Sqmm size, PVC insulated and unsheathed 1100 volts grade single core multistrand copper conductor FRLS cable drawn into and including PVC casing capping with all fittings and accessories with PVC box fixed with CP screws and cup washers for mounting fitting like switches, sockets and fan regulators etc; including one continious run of PVC FRLS insulated green colour 1.5 sqmm multi stranded copper conductor cable earth wire and connected to common earth dolly complete all as specified and directed for the following point (Switches, sockets, fan regulators, etc. will be measured and paid for separately) :-\n(a) one light /fan point controlled by one; one way switch.\n 30 Per Point
20 20 (b) one 3 pin socket out let 5 amp on independent board.\n 10 Per Point
21 21 (c) one 3 pin socket out let 5 amp point on the same board with other switch. \n 10 Per Point
22 22 All as per Ser no item 19 here in before but with 2.5 sq mm size PVC FRLS insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board including one continuos run of PVC FRLS insulated green in colour 2.5 sqmm multistranded copper conductor earth wire connecting to earth dolly complete all as specied and directed.\n 10 Per Point
23 23 Material and labour for point wiring with 1.5 Sqmm size PVC insulated and unsheathed 1100 volts grade single core multistrand copper conductor FRLS cable drawn into and including PVC conduit with all fittings and accessories with PVC box fixed with CP screws and cup washers for mounting fittings including one continous run of PVCFRLS insulated green colour 1.5 sq mm multi stranded copper conductor cable earth wire and connected to common earth dolly complete all as specified and directed for the following (Switches, sockets, fan regulators, etc. will be measured and paid for separately :-\n(a) one light /fan point controlled by one; one way switch.\n 30 Per Point
24 24 (b) one 3 pin socket out let 5 Amp on independent board.\n 10 Per Point
25 25 (c) one 3 pin socket out let 5 amp point on the same board with other switch.\n 10 Per Point
26 26 All as per Ser item 23 above but with and including 2.5sq mm size PVC FRLS insulated and unsheathed 1100 volts grade single core stranded (multistranded) copper conductor cable for 3 pin socket outlet 15 amp on independent board including one continuos run of PVC FRLS insulated green in colour 2.5 sqmm multistranded copper conductor earth wire connecting to earth dolly.complete all as specified and directed\n 10 Per Point
27 27 Material and labour for point wiring with 1.5 Sqmm size, PVC insulated and unsheathed 1100 volts grade single core multistrand copper conductor FRLS cable drawn into existing PVC conduit / ERW steel conduit concealed into wall or on surface with all fittings and accessories with PVC box fixed with CP screws and cup washers for mounting fitting like switches, sockets and fan regulators etc; including one continious run of PVC FRLS insulated green colour 1.5sqmm multi stranded copper conductor cable earth wire and connected to common earth dolly complete all as specified and directed for the following (Switches, sockets, fan regulators, etc. will be measured and paid for separately) :-\n(a) one light /fan point controlled by one; one way switch. \n 50 Per Point
28 28 (b) Two way light point controlled by one; one way switch. \n 5 Per Point
29 29 (d) one 3 pin socket out let 5 amp on independent board. \n 10 Per Point
30 30 (e) one 3 pin socket out let 5 amp point on the same board with other switch. \n 10 Per Point
31 31 All as per sl item 27 above but with 2.5sq mm size PVC FRLS insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board including one continuos run of PVC FRLS insulated green in colour 2.5 sqmm multistranded copper conductor earth wire connecting to earth dolly. complete all as specified and directed.\n 10 Per Point
32 32 Material and labour for Point wiring with 1.5 Sqmm, PVC insulated and unsheathed FRLS cable of copper conductor, multistranded, single core 1100 volts grade in and including stove enameled / ERW steel conduit along with all accessories such as bends, elbows, juntion boxes on surface of walls, ceiling etc; for and connecting up of the fitting, including 1.5 sqmm dia PVC insulated copper conductor to PVC insulated unsheathed FRLS cable green in colour for earth countinuity and connected to earth dolly complete all as specified and directed for the following (Switches, sockets, fan regulators, etc. will be measured and paid for separately:-\n(a) One light point / fan point controlled by one; single pole switch.\n\n\n 100 Per Point
33 33 (b) Two way light point controlled by one; single pole switch. \n 10 Per Point
34 34 All as per SI item No. 32 above but with 2.5 sqmm cable for 16 Amps, 3 pin switch socket combination.\n 30 Per Point
35 35 Supply and fixing switch piano, flush type single pole, one way, 5 Amps, 240 volts complete all as specified and directed. 200 Each
36 36 Supply and fixing socket 2 in 1, 3 pin, 5 Amp, flush type complete all as specified and directed. 100 Each
37 37 Supply and fixing switch socket combination 5 in 1, 6 pin, 5A/16A flush type complete all as specified and directed. 50 Each
38 38 Supply and fixing Ceiling rose surface Bakelite, 65 mm x 50 mm three terminals 230 Volts, AC Single phase complete all as specified and directed. 30 Each
39 39 Supply and fixing in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed. 50 Each
40 40 Supply and fixing in repairs flameproof switch socket combination suitable for 2P+N 16 Amps, 250 volts including plug and top, LM-6 body, CMRI certified, ISI marked complete all as specified and directed.\n 5 Each
41 41 Supply and fixing in repairs flameproof switch socket combination 2P+N suitable for 25 Amps to 32 Amps, 250 volts including plug and top, LM-6 body, CMRI certified, ISI marked complete all as specified and directed.\n\n 5 Each
42 42 Taking down existing unserviceable submain wiring any type wiring alongwith complete accessories and making good the disturbed surfaces complete all as specified and directed.\n 550 Running Metre
43 43 Material and labour for Sub main wiring with and including single core, multistranded FRLS PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn in existing steel rigid conduit on surface wall / roof / floor with one run of suitable size FRLS PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dully complete all as specified and directed for following size / runs : - .\nNOTE :- 4 / 2 runs of main wire along with 1 run of earth wire shall be measured as one unit (Running metre).\na) 2 x 1.5 sqmm + 1 x 1.5 sqmm earth wire\n\n 200 Running Metre
44 44 b) 4 X 4 sqmm + 1 X 4 sqmm earth wire. 50 Running Metre
45 45 c) 2 X 2.5 sqmm + 1 X 1.5 sqmm earth wire. 50 Running Metre
46 46 e) 2 x 4 sqmm + 1 x 2.5 sqmm earth wire. 50 Running Metre
47 47 Material and labour for Sub main wiring with and including single core, multistranded PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn in and including PVC rigid conduit ,PVC Casing and capping, conduit fittings and accessories on surface wall / roof / floor with one run of suitable size PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dully complete all as specified and directed for following size / runs :-.\nNOTE :- 4 / 2 runs of main wire along with1 run of earth wire and one run of conduit / casing & caping shall be measured as one unit (Running metre).\na) 4 X 6 sqmm + 1 x 6 sqmm earth wire 50 Running Metre
48 48 b) 4 X 4 sqmm + 1x 4 sqmm earth wire 50 Running Metre
49 49 c) 2 X 6 sqmm + 1x 4 sqmm earth wire 50 Running Metre
50 50 b) 2 X 4 sqmm + 1 X 2.5 sqmm earth wire 50 Running Metre
51 51 Supply and fixing LED luminaires 70 watts energy saving , enviourment friendely and robust IP65 protected LED midbay with PDC housing sutable for celing surface/suspended amounted, heavy duty with clamp and fixing arrangement complete all as specified and directed.\n\n\n 22 each
52 52 Supply and fixing LED light fitting surface and wall mounted LED batten 4 feets, extruded aluminium housing provided for efficient heat dissipation with policarbonate diffuser and driver with and including 20 Watt LED (4 feet) including PVC three core flexible copper conductor cable from ceiling rose to connector of fittings complete all as specified and directed. 100 Each
53 53 Supply and fixing LED Luminaires 2' x 2' recess mounting aesthetically designed glare free symmetrical illumination 34 W delivery lumens are not less than 3400 lumens / watts, 230 V energy efficient box type white epoxy powder coated aluminiunm extruded housing with LEDs and drive complete, connector block etc suitable for POP ceiling complete with and including all accessories, pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.\n 15 Each
54 54 Supply and fixing LED Luminaires 2' x 2' surface mounting aesthetically designed glare free symmetrical illumination 36 W delivery lumens are not less than 3400 lumens / watts, 230 V energy efficient box type white epoxy powder coated aluminiunm extruded housing with LEDs and drive complete, connector block etc suitable for POP ceiling complete with and including all accessories, pre-wired and including connecting up with and including twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.\n 20 Each
55 55 Supply and fix LED security/street light fitting well glass LED 70 (CDL) watts new generation energy saving and environmental friendly, pressure die-cast aluminium housing IP 65 protection with high efficiency power LED 70 (CDL) watts, electronic driver including PVC three core flexible copper conductor cable from ceiling rose to connector of fitting complete all as specified and as directed.\n 10 Each
56 56 Taking down carefully by unscrewing fittings and fixtures such as flameproof light fitting from poles at any height and removalcomplete all as specified and directed. 20 Each
57 57 Supply and fixing in repairs flameproof / wheather proof LED well glass light fitting 45 Watts with lumen out put not less than 4400 lumens, body made of aluminium alloy, LM -6 body, epoxy painted including wire guard relfector, flameproof heat resistant clear toughened ‘type- A’ with LED chip including suitable electronic ballast, all as Gas Gr. IIA, IIB Certified by CMRI Dhanbad and CCOE (PESO) Nagpur along with ISI marking Glass including necessary fixing arrangments and connecting up completely all as specified and directed. 10 each
58 58 Supply and fixing in repairs flameproof / weatherproof LED well glass light fitting suitable for 60 Watt with lumen out put not less than 6000 lumens, body made out of aluminium alloy LM -6 body epoxy painted with wire guard relfector, flameproof heat resistant clear toughened ‘type- A’ with LED chip including suitable electronic, all as Gas Gr. IIA, IIB Certified by CMRI Dhanbad and CCOE (PESO) Nagpur along with ISI marking Glass including necessary fixing arrangments and connecting up completely all as specified and directed. 10 each
59 59 Taking down flameproof well glass fittings 70 W / 125W / 250 W HPMV / HPSV / 160W MLL for modification to bring energy conservation concept by providing in replacement of suitable type holders and LED retrofit type bulb 20 Watts / 30 watts directly connected to the system and refixing in postion after necessary modofication complete all as specified and adirected. .\nNote : LED bulb 30 watts and holder will be measured and paid separately as 'supply only' items here in after .\n 50 Each
60 60 Dismantling carefully, disconnecting and taking down the old unserviceable tube light fitting, 1 x 40W / 36W, 2 x 40W / 36W, any type and make from wall / ceiling at any height and carrying out necessary repairs, cleaning of cover and providing internal wiring with suitable copper wire, replacement of tube light / rod, holders, etc. and refixing in position complete all as specified and directed.\nNOTE : Tube light / rod & holder required to be replaced will be measured and paid saparately as 'supply only'items here in after..\n 150 Each
61 61 Dismantling carefully, disconnecting and bringing down the existing unserviceable FLP tube light fitting, 1 x 40 W / 36 W , 2 x 40W / 36 W, any type, and make from wall / ceilings, at any height and carrying out necessary repairs, cleaning of cover and providing internal wiring with suitable copper wire, replacement of tube light / rod, holders, etc , and refixing in position complete all as specified and directed.\nNOTE : Tube light / rod & holder required to be replaced will be measured and paid saparately as 'supply only'items here in after.\n\n 200 Each
62 62 Supply only LED rectofit tube light / rod 20 watts of size 4 feet crystal glass one side connection with G13 lamp holder suitable for existing T8 tube light fitting complete all as specified and directed. 100 Each
63 63 Supply only LED rectofit tube light / rod light 20 watts of size 4 feet polycarbonate single side connecion with G13 lamp holder suitable for existing T8 tulight fitting complete all as specified and directed. 150 Each
64 64 Supply only LED rectofit tube light / rod 20 watts of size 4 feet polycarbonate THD two side connecion with G13 lamp holder suitable for existing T8 tube light fitting complete all as specified and directed. 100 Each
65 65 Supply only LED lamp 30watts EN27 Floride complete all as specified and directed.\n 50 Each
66 66 Supply only porceline holder suitable for 20 watts / 30 watts well glass existing light fitting complete all as specified and directed. 30 Each
67 67 Supply and fixing MCB 10 kA 'C curve' on existing distribution board out going / incoming any type and connecting to existing circuits complete all as specified and as directed for the following size : - \na) MCB SP 6 amps to 32 amps. 100 Each
68 68 b) MCB SPN 16 amps to 32 amps. 20 Each
69 69 c) MCB SPN 40 amps to 63 amps. 5 Each
70 70 d) MCB TPN 63 amps. 10 Each
71 71 Supply and fixing in repairs factory made TPN distribution board double door flush type as per IS 8623 made from sheet metal duly powder coated for single phase outgoing and three phase incomer, with and including 200 Amps rated bus bar, 4 ways 415 Volts, flush with wall complete with and including all accessories complete all as specified and directed. 3 Each
72 72 Supply and fixing in repairs factory made TPN distribution board double door flush type as per IS 8623 made from sheet metal duly powder coated for single phase outgoing and three phase incomer, with and including 200 Amps rated bus bar, 8 way 415 Volts, flush with wall complete with and including all accessories complete all as specified and directed. 2 Each
73 73 Supply and fixing in repairs factory made distribution board double door flush type all as per IS 8623 made from sheet metal duly powder coated to be fixed flush with wall complete with and including 200 amps rated bus bar, all accessories complete all as specified and directed for the following sizes :-\na) SPN 8 ways 240V. 5 Each
74 74 b) SPN 12 ways 240V. 5 Each
75 75 Supply and fixing in repairs MCCB suitable KA rating , 415 Votls, AC 50 Hz thermal released fixed type, conforming to IS- 60947-2 including suitable arrangement to existing LT panel for proper seating / opration complete all as specified and directed for the following sizes /capacities :-\nMake: L&T, Legrand,C&S, ABB\n(a) 63 amps 16 KA 415V capacity 3 pole. 3 Each
76 76 (b) 100 amps 16 KA capacity 3 pole. 2 Each
77 77 (c) 200 amps 25 KA capacity 3 pole. 2 Each
78 78 (d) 250 amps 35 KA capacity 3 pole. 2 Each
79 79 Taking down carefully ceiling fan / wall mounted fan / pedestal fan / exhaust fan of any sweep / size from any location at any height after disconnecting from the live line, transpotation the same from site to workshop for repair including dismantling of the fan blades, motor, brackets for repairs and reassembling it complete after overhaulling, oiling, gresing, replacing unserviceable parts, painting and refixing at location and testing at site complete all as specified and directed.\nNotes : (i) Spare parts required to be replaced except minor items will be measured and paid separtely as "Supply only" items here-in after, (ii) Painting and rewinding of fan will also be measured separately under respective item of BOQ here-in after. 50 Each Job
80 80 Supply only flexible twin twisted copper wire two core of size 2.5 sqmm / 0.0076 mm upto 1.5 metre length complete all as specified and directed.\n 50 Running Metre
81 81 Supply only ball bearing suitable for Ceiling fan 1200 mm /1400 mm sweep complete all as specified and directed.\n\n 10 Each
82 82 Supply only ball bearing suitable for exhaust fan 400 mm to 450 mm sweep complete all as specified and directed.\n\n 20 Each
83 83 Supply only ball bearing suitable for exhaust fan up to 300 mm sweep complete all as specified and directed.\n\n 5 Each
84 84 Supply only condensor 2.5 mfd, 230 V, suitable for ceiling fan / wall fan / exhaust fan of any sweep and size complete all as specified and directed\n\n 50 Each
85 85 Supply only condensor 4 mfd, 230 V suitable for wall mounting fan / exhaust fan / pedesta l fan of any sweep / size complete all as specified and directed.\n\n 50 Each
86 86 Supply only rubber reel with suitable size MS nuts, bolts, locking pins suitable for ceiling fan down rod of any size / dia as per existing complete all as specified and directed 10 Each
87 87 Supply only gun metal bushing for ceiling fan 1200 mm / 1400 mm sweep any make complete all as specified and directed.\n 10 Each
88 88 Supply only gun metal bushing for Exhaust fan upto 300 mm sweep any make complete all as specified and directed.\n 5 Each
89 89 Material and labour for rewinding of ceiling fan 1200 mm to 1400 mm sweep / wall mounted fan / pedestal fan of any size / sweep including removing old burnt winding, cleaning the starter with CTC solution to remove the burnt slots and rewinding the fan with and including super enameled copper wire of suitable gauge, size, number of turns, insulation varnishing and reassembling complete all as specified and directed.\n 20 Each
90 90 Material and labour for rewinding of exhaust fan 400 mm to 450 mm sweep including removing old burnt winding, cleaning the starter with CTC solution to remove the burnt slots and rewinding the fan with and including super enameled copper wire of suitable gauge, size, number of turns, insulation varnishing and reassembling complete all as specified and directed.\n 10 Each
91 91 Material and labour for rewinding of exhaust fan 300 mm sweep including removing old burnt winding, cleaning the starter with CTC solution to remove the burnt slots and rewinding the fan with and including super enameled copper wire of suitable gauge, size, number of turns, insulation varnishing and reassembling complete all as specified and directed.\n 5 Each
92 92 Material and labour for painting of ceiling fan / exhaust fan and wall mounted fan / exhaust fan / air circulators of any size or sweeps complete including fan blades, down rod, fan motor body after preparation of surfaces, cleaning and applying one coat of painting with white synthetic enamel paint by spray gun and pasting soft stickers indicating MES No. of 25 mm size each letter with black syenthetic enamel paint complete all as specified and directed.\n 30 Each
93 93 Material and labour for painting of FLP exhaust fan and wall mounted fan of any size or sweeps complete including fan blades, down rod, fan motor body after preparation of surface, cleaning and applying one coat of painting with white synthetic enamel paint by spray gun and pasting soft stickers indicating MES No. of 25 mm size each letter with black syenthetic enamel paint complete all as specified and directed.\n 10 Each
94 94 Supply and fixing in reapirs ceiling fan of size 1200 mm of five star rating including making connection and depositing old fan in store yard in MES complete all as specified and directed. 38 Each
95 95 Supply and fix in reapirs PVC armoured copper cable of 2.5 sqmm 3 core including saddling on wall / surface complete all as specified and directed. 200 Running Metre
96 96 Supply and fix in repairs FLP flexible hose conduit 20 mm dia 300mm long complete all as specified and directed. 22 Each