Provision Of Sentry Post Near Silver Oak , Improvement Of Electric Supply , Provn Of Heavy Duty Fans Including Connected Works And Certain Revenue Works At Dssc Wellington ., WELLINGTON-Tamil Nadu

Military Engineer Services-MES has published Provision Of Sentry Post Near Silver Oak , Improvement Of Electric Supply , Provn Of Heavy Duty Fans Including Connected Works And Certain Revenue Works At Dssc Wellington .. Submission Date for this Tender is 28-01-2021. Cabin Tenders in WELLINGTON Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

26021725
Corrigendum : Provision Of Sentry Post Near Silver Oak , Improvement Of Electric Supply , Provn Of Heavy Duty Fans Including Connected Works And Certain Revenue Works At Dssc Wellington .
National Competitive Bid
Indian
Tamil Nadu
WELLINGTON
28-01-2021

Tender Details

provision Of Sentry Post Near Silver Oak , Improvement Of Electric Supply , Provn Of Heavy Duty Fans Including Connected Works And Certain Revenue Works At Dssc Wellington .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Nov-2020 REVISED BOQ BOQ 30-11-2020
2 30-Nov-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-12-2020
3 07-Dec-2020 DATE POSTPONED Date 10-12-2020
4 10-Dec-2020 Extend date Date 14-12-2020
5 14-Dec-2020 extend date Date 17-12-2020
6 17-Dec-2020 extend Date 21-12-2020
7 21-Dec-2020 date Date 24-12-2020
8 24-Dec-2020 date extn Date 31-12-2020
9 31-Dec-2020 extended Date 11-01-2021
10 11-Jan-2021 Postponedtender9 Date 28-01-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 14000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVN OF SENTRY POST NEAR SILVER OAK, IMPROVEMENT OF ELECTRIC SUPPLY, PROVN OF HEAVY DUTY FANS INCLUDING CONNECTED WORKS AND CERTAIN REVENUE WORKS AT DSSC WELLINGTON.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches, n.exc 1.5m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc area n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed. 5 Cum
2 2 M & L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed. 1 Cum
3 3 M & L for precast cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc 10 cm in width and set in CM (1:6) complete all as specified and directed by Engr-in-Charge. 5 Cum
4 4 Returning, filling in, including spreading levelling, watering and well ramming in layers n.exc 25 cm in thick back side of wall using excavated soil all as specified and directed by Engr-in-Charge. 7.5 Cum
5 5 Removing of excavated soil to a distance n.exc 50m and depositing where directed at level n.exc 1.5m from the starting point all as specified and directed. 8.5 Cum
6 6 M & L for 40mm thick damp proof course in cement concrete (1:2:4), type B-0 (using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. 1.5 Sqm
7 7 M & L for RCC (nominal mix) (1:2:4) type B-1 (using 20mm graded stone aggregate) as in arch beams, cantilevers, bressummers, lintels over 1.5 m span etc complete all as specified and directed. 0.2 Cum
8 8 M & L for use and waste of timber as in form work to sides and soffits of roof beam, beam haunchings, girders, bressummers, lintels , cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc flat fair finished surfaces all as specified and directed. 4 Sqm
9 9 M & L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hopping for columns,hooking ends and binding with and including MS wire (annealed) not less than 0.90 mm dia complete all as specified and directed. 20 Kg
10 10 All as per item No 9 above but 5 mm and over upto and including10 mm dia as in stirrups all as specified and directed. 12 Kg
11 11 S & F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (Gde- E- 250) quality- A complete all as specified and directed by Engr-in-Charge. 220 Kg
12 12 S & F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed in position with required shape and tapping screw complete all as specified and directed by Engr-in-Charge. 7.5 Sqm
13 13 S & F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof cover / cladding to wall, fixed with self tapping screws all as specified and as directed. 2.5 Sqm
14 14 M & L for sand filling under floors including spreading, levelling, well ramming, watering in required layers n.exc 25cm thick complete all as specified and as directed. 0.5 Cum
15 15 M & L for hard core of broken stone or boulders n.exc 63 mm size deposited, spread and levelled in layers n.exc 15cm thick,watered and rammed to a true surface complete all as specified and directed. 0.5 Cum
16 16 M & L for for providing 75mm thick cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in sub base, finished even and rough to receive top layer finish complete all as specified and as directed. 3 Sqm
17 17 M & L for for providing 75mm thick cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection/ pavings, finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. 6 Sqm
18 18 M & L for durastone tile of 300 x 300 x 12-16mm thick, as in floors and skirting, set and jointed in neat cement slurry and pointed with white or coloured cement to match with tile, laid over and including screed bed 15mm thick in CM (1:4) complete all as specified and as directed. 8 Sqm
19 19 S & F 12 mm thick frosted with etching glass with any design and shape of (Like owl design etc) for entry window and door including removing existing glass and necessary arrangment for fixing complete all as specified and as directed by GE.\nNote : Melamine polising is to be done to wooden surface of door and window after fixing of glass. 8 Sqm
20 20 M & L for granite (of any type) 18 to 20mm thick machine cut, as in walls, steps, jambs, pillars, window cills, cooking platforms and floorings, set and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, moulding, rounding edges as required, laid over and including 10mm thick screed bed in CM (1:3) including necessary engraving, coloring of size not less than 10mm width complete all as specified and directed by Engr-in-Charge 11 Sqm
21 21 M & L for granite (of any type) 18 to 20mm thick with any design and shape ( Like Owl design and letters not exc 15cm high etc) machine cut, as in walls, steps, jambs, pillars, window cills, cooking platforms and floorings, set and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, moulding, rounding edges as required, laid over and including 10mm thick screed bed in CM (1:3) including necessary engraving, coloring of size not less than 10mm width complete all as specified and directed by Engr-in-Charge 1 Sqm
22 22 M & L for rendering 15 mm thick in CM (1:6) mixed with WPC as per manufacturer's instruction on concrete surface, finished even and smooth without using extra cement complete all as specified and as directed.\nNote: Water proofing compound shall be measured and paid separately. 15 Sqm
23 23 Supply only liquid water proofing compound complete all as specified and as directed. 2 Litres
24 24 M & L for rendering 15 mm thick in CM (1:4) mixed with WPC as per manufacturer's instruction on concrete surface, finished even and smooth without using extra cement complete all as specified and as directed.\nNote: Water proofing compound shall be measured and paid separately. 12 Sqm
25 25 M & L for preparation of new plastered surfaces of external wall and applying two coats of anti fungal paint (weather coating) over a coat of exterior primer complete all as per manufacturer's instruction and as directed by Engr-in-Charge. 12 Sqm
26 26 M & L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as per manufacturer's instruction and as directed by Engr-in-Charge. 15 Sqm
27 27 M & L for preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. 12 Sqm
28 28 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removing unserviceable debris off the premises, all as specified and directed. 34 Cum
29 29 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. 6 Qtls
30 30 Removing excavated material to a distance exc 500m but n.exc 1.50 Km and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. 34 Cum
31 31 M & L for providing temporary arrangements for screening wall (made of steel pipe, hesian cloth etc) of height 15 mtr and length 15 mtr to protecting near by existing bldg for slipping out of debris from existing peripheral of over head tank for all as specified and directed by Engr-in-Charge. \nNote : Temporary arrangement to be dismantled after complete demolition of over head tank. 1 Each Job
32 32 Labour for separating, scraping and cleaning of reinforcement complete all as directed by Engr-in-Charge.\nNote : Demolished materials obtained shall be measured and paid separately. 56 Qtls
33 33 Removal of iron scrap obtained from demolition of OH Tank and removing/staking at MES Storeyard (2KM away from site) including loading, unloading, stacking and transport complete all as specified and as directed by Engr-in-Charge. 56 Qtls
34 34 Supply, install, commissioning & testing of Heavy Duty Exhaust Fan, 600 mm sweep, 900 RPM, Air Delivery not less than 10520 M3/Hr, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 2.5 Sqmm from ceiling rose to fan in flexible hose including writing of MES Number 2.0 cm height with synthetic enamel paint incl making of suitable sized hole in wall/existing window/ventilator/other surfaces for fixing of the exhaust fan & making good the disturbed surfaces (if any) complete all as specified and as directed. Make : Havells, Model : Turboforce HD or techno-commercially equivalent of Almonard /Usha /Crompton. 8 Each
35 34.1 NOTE: \n(i) Design / drawing / BOM / technical specifications of the Heavy Duty Exhaust Fans showing the dimensions etc. is to be obtained from OEM / Auth Channel Partner / Supplier & is to be got approved from Engr-in-charge & GE before placing final order. Techno-Commercial Comparative Analysis is also required to be submitted to Engr-In-Charge & GE wherever equivalency w.r.t. a given Make/Model/Cat-Part Ref is concerned.\n(ii) The cost of making suitable sized hole in wall/existing window/ventilator/other surfaces for fixing of the exhaust fan & making good the disturbed surfaces incl any kind of frame work/cement work/wood work/steel/welding work etc. required for proper fixing of the heavy duty exhaust fan & matching to the existing surface is deemed to be included in the unit quoted rates.\n(iii) The cost of providing a suitable square shaped netted (wire mesh) structure as bird screen guard on the outer surface of the building outside incl connected works viz. steel/welding work etc. for fixing/installation of the same is also deemed to be included in the unit quoted rates.\n(iv) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.\n(v) The approximate height of installation/fixing of the exhaust fans is around 8 to 10 Mtrs from building plinth level.\n(vi) Contr/Firm is required to visit the site of work for any doubts/clarifications w.r.t. specifications/qty etc. before quoting of the Tender. Any query/clarifications etc. after conclusion of the Contract shall NOT be entertained & decision of the AO shall be final & binding.
36 35 M&L for earthing complete with GI plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC chamber & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI wire for protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed by Engr-in-Charge.\nNote: If the desired earth resistance is not obtained, the earthing will be redone at no extra cost for the full satisfaction of Engr-in-Charge 2 Each Set
37 36 S & F ceiling rose, PVC /polycarbonate, insulated body, 3 terminals and 240 Volts, ISI marked complete all as specified & as directed. 8 Each
38 37 M & L for surface sub-main wiring alongwith earth wire of size of 2 x 2.5 Sq. mm + 1 x 2.5 Sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non- metallic rigid PVC medium grade Conduit and accessories ISI marked of appropriate size/thickness on walls/other surface etc. complete all as specified and as directed. \nNote : Two runs of PVC wire, one run of earth wire & one run of PVC conduit will be measured as one length. \nMake: Havells/Polycab/Finolex 240 RM
39 38 S & F MCB, DB, TPN, 6 ways, DOUBLE DOOR, IP-54, Ik-09 with metal door, rated bus bars, earth bar, neutral links complete incl. blanking plates as required & fixed flush to wall/other surface complete all as specified and as directed. \nMake : L&T/ABB/LEGRAND. 1 Each
40 39 S & F MCB, TPN, 10KA, 415V, "C" curve, 32 A, ISI marked complete all as specified and as directed. \nMake : L&T/ABB/LEGRAND. 2 Each
41 40 S & F MCB, SPN, 10KA, 230V, "C" curve, 06-32 A, ISI Marked complete all as specified and as directed. \nMake : L&T/ABB/LEGRAND. 17 Each
42 41 S & F 40 mm dia GI pipe light grade on walls, floors under ducts/culverts etc. for protection of earthing lead complet all as specified and as directed. \nMake : TATA/JINDAL/PRAKASH 6 RM
43 42 M & L for cutting the existing hard standing /PCC / WBM road at a depth not less than 45 cm and 25 cm in width for passing of cable through GI pipe, returning filling in, complete including finishing the surfaces by providing cement concrete type B-1 (1:2:4) with 20 mm grade aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and directed by Engr-In-Charge. 6 RM
44 43 Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 16 Sq mm, 4.0 core complete all as specified and as directed. \nMake : HAVELLS /FINOLEX /POLYCAB /GLOSTER 50 RM
45 44 Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in hard/dense soil complete all as specified and as directed. 11 Cum
46 45 M & L for providing sand cushioning for protection of UG cable in trenches with dry ( coarse ) sand approved quality including filling ,spreading and punning down to desired thickness complete all as specified and as directed.\nNote: Punned thickness shall only be measured for payment purpose 4 Cum
47 46 Supply and laying sub class "B" bricks in trenches for protection of UG Cable complete all as specified and as directed. 400 Each
48 47 Supply, install, commissioning & testing of Compact Enclosed ATS (Automatic Transfer Switch) suitable for outdoor mounting & I-O-II operation, 4 Pole, 125 A, confirming to IEC 60947-6-1 complete with following features/specifications :\n(i) Double-Break Contact System offering High Short-time Withstand. \n(ii) Ample Space for Cable Termination.\n(iii) Ease of Generator Control (ON-OFF, Cooling Cycle Self-Test).\n(iv) Cyclic Event Logger.\n(v) Priority Source Selection. 1 Each
49 47.1 (vi) Adjustable Time Delay (0.1 Sec to 3 Hrs).\n(vii) Suitable for 3-Phase as well as 1-Phase sources.\n(viii) Protections - UV/OV, Phase Sequence, Single Phasing, Frequency.\n(ix) Terminal Shrouds, Phase Barriers & Source Separator etc.(x) Surge arrestor, type-1+2 with Imax 50KA of configuration 3P+N of 4 module, confirms to IEC 61643-11 - 01 No. Cat No : AUSP123PN50 of L&T or techno-commercillay eqvt in ABB/SIEMENS\nModel - Enclosed ATS, Frame 2, Type - 125 A, Cat No CK90161BSOO of make L&T or techno-commercially equivalent of ABB/Siemens.\nNote: \n(i) Design / drawing / BOM of the Compact Enclosed ATS showing the dimensions is to be obtained from OEM / Auth Supplier & is to be got approved from the Engr-In-Charge & GE before placing final order to the manufacturer.\n(ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.\n(iii) The entire installation & testing work of the Compact ATS is to be got done from the OEM or their auth Rep/Sister Concern/Channel Partners only.\n(iv) In the event of the Compact ATS being of Indoor type (as available from OEM), suitable arrangements w.r.t. shed/covering etc. as decided by GE & Engr-In-Charge shall have to be arranged by the Contr so as to make the same completely weather-proof & suitable for outdoor mounting. Cost of the same is deemed to be included in the unit quoted rates.\n(v) The incoming supply should go through surge arrestor mentioned above
50 48 Supply, install, commissioning & testing of LT control panel board "out-door type" of size 1200 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified & as directed with & incl the following accessories : 1 Each
51 48.1 BUS-BAR & INTERNAL CONNECTIONS :\nThe bus-bars shall be made up of 04 Nos high grade Aluminium 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.\nPROVISION FOR CABLE ENTRY :\nThe provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.\nINCOMING :\n(a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 160 to 200 A - 01 Nos. Cat No : CM90642OONO of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.\n(b) Onload changeover switch, open-execution modular construction type, confirming to IS/IEC 60947-3, rated current 200 A, 415 V, 4P - 01 Nos. Cat No : CO22000OOOA, Type CO2-200 of make L&T or techno-commercially equivalent of ABB/SIEMENS.
52 48.2 OUTGOINGS :\n(a) MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting,suitable for isolation, having breaking capacity 25 KA & of rating 80 to 100 A - 03 Nos (2W+1S). Cat No : CM91712OOKOOG of Make L&T or techno-commercially equivalent of LEGRAND/SIEMENS.\nINSTRUMENTATION SYSTEM :\n(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 0.5, 3 phase, Size 96 x 96 mm. Cat No WL411020OOOO of make L&T or techno-commercially equivalent of ELMEASURE/SECURE.\n(b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.\n(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 02 Nos (Front & Back).\nNote : \n(i) Design / drawing / BOM of the Panel Board showing the dimensions is to be obtained from the Manufacturer / Supplier & is to be got approved from the Engr-In-Charge & GE before placing final order to the manufacturer.\n(ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
53 49 M & L for earthing complete with GI plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC chamber & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip for protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed by Engr-in-Charge.\nNote: If the desired earth resistance is not obtained, the earthing will be redone at no extra cost for the full satisfaction of Engr-in-Charge 2 Each Set
54 50 M & L for surface point wiring with 2.5 Sqmm single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade Casing-capping and accessories ISI marked on walls/other surface etc. incl provision of 2.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) for 15 Amps switch socket outlets etc complete all as specified and as directed. 15 Point
55 51 S & F modular switch, one way, 16 Amp, 1 Module, 240 volts, ISI marked complete all as specified and as directed. \nMake : Havells CRABTREE (VERONA) /Anchor ROMA/LEGRAND 15 Each
56 52 S & F modular shuttered socket outlet 3 Pin, 6/16 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. \nMake : Havells CRABTREE (VERONA)/Anchor ROMA/LEGRAND 15 Each
57 53 S & F modular 3M cover plate with support plate - Pearl White complete all as specified and as directed. \nMake : Havells CRABTREE (VERONA)/Anchor ROMA/LEGRAND 15 Each
58 54 S & F modular 3M Metal Flush Box complete all as specified and as directed. \nMake : Havells CRABTREE (VERONA)/Anchor ROMA/LEGRAND 15 Each
59 55 S & F MCB, DB, TPN, 4 ways, DOUBLE DOOR, IP-43, Ik-09 with metal door, rated bus bars, earth bar, neutral links complete incl. blanking plates as required & fixed flush to wall/other surface complete all as specified and as directed. \nMake : L&T/ABB/LEGRAND. 2 Each
60 56 S & F MCB, DB, SPN, 12 ways DOUBLE DOOR, IP-43, Ik-09 with metal door, rated bus bars, earth bar, neutral links complete incl. blanking plates as required & fixed flush to wall/other surface complete all as specified and as directed. \nMake : L&T/ABB/LEGRAND. 2 Each
61 57 S & F MCB, TPN, 10KA, 415V, "C" curve, 40-63 A, ISI marked complete all as specified and as directed. \nMake : L&T/ABB/LEGRAND. 2 Each
62 58 S & F MCB, SP, 10KA, 230V, "C" curve, 06-32 A, ISI Marked complete all as specified and as directed. \nMake : L&T/ABB/LEGRAND. 30 Each