Kerala Water Authority-KWA has published Jjm Thrissur District Vadanappilly Gramapanchayath Providing Fhtc To Rural House Holds And Allied Works . . Submission Date for this Tender is 06-11-2020. Pipe Laying Tenders in Vadanappilly Kerala. Bidders can get complete Tender details and download the document.
Work Name: JJM–Thrissur district– Vadanappilly Gramapanchayath -Providing FHTC to Rural house holds and allied works. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Appendix A - Distribution strengthing (Working Charge) | BI01010001010000000000000515BI0100001112 | ||
2 | 1.001 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR) | BI01010001010000000000000515BI0100001113 | 13646 | cum |
3 | 1.002 | Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009) | BI01010001010000000000000515BI0100001114 | 6500 | metre |
4 | 1.003 | Open timbering in trenches including strutting and shoring complete ( measurements to be taken of the face area timbered ):Depth not exceeding 1.5 m | BI01010001010000000000000515BI0100001115 | 3172.5 | sqm |
5 | 1.004 | Bailing out water with 5 HP engine and pumpset including conveyance to the site, errection, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc. complete.NEW DATA (Prepared based on PHED SDB - Item No.1070 | BI01010001010000000000000515BI0100001116 | 500 | Kwh |
6 | 1.005 | Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 600 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.24 in DAR | BI01010001010000000000000515BI0100001117 | 100 | metre |
7 | 1.006 | Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 450 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.22 in DAR | BI01010001010000000000000515BI0100001118 | 733 | metre |
8 | 1.007 | Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 400 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.21 in DAR | BI01010001010000000000000515BI0100001119 | 182 | metre |
9 | 1.008 | Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials :350 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.20 in DAR | BI01010001010000000000000515BI0100001120 | 987 | metre |
10 | 1.009 | Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 300 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.19 in DAR | BI01010001010000000000000515BI0100001121 | 1673 | metre |
11 | 1.01 | Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 250 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.18 in DAR | BI01010001010000000000000515BI0100001122 | 2503 | metre |
12 | 1.011 | Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials :200 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.17 in DAR | BI01010001010000000000000515BI0100001123 | 251 | metre |
13 | 1.012 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 90 mm nominal outer dia pipes." | BI01010001010000000000000515BI0100001124 | 9000 | metre |
14 | 1.013 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes. | BI01010001010000000000000515BI0100001125 | 3000 | metre |
15 | 1.014 | Conveying and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) excluding cost of pipe and specials: 400 mm dia C.I.Double Fanged Pipe Data derived from 18.71.7 in DAR | BI01010001010000000000000515BI0100001126 | 15 | metre |
16 | 1.015 | Conveying and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) excluding cost of pipe and specials: 350 mm dia C.I.Double Fanged Pipe Data derived from 18.71.6 in DAR | BI01010001010000000000000515BI0100001127 | 15 | metre |
17 | 1.016 | Conveying and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) excluding cost of pipe and specials: 300 mm dia C.I.Double Fanged Pipe Data derived from 18.71.5 in DAR | BI01010001010000000000000515BI0100001128 | 15 | metre |
18 | 1.017 | Conveying and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) excluding cost of pipe and specials: 250 mm dia C.I.Double Fanged Pipe Data derived from 18.71.4 in DAR | BI01010001010000000000000515BI0100001129 | 15 | metre |
19 | 1.018 | Conveying and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) excluding cost of pipe and specials: 200 mm dia C.I.Double Fanged Pipe Data derived from 18.71.3 in DARData for 5 m | BI01010001010000000000000515BI0100001130 | 15 | metre |
20 | 1.019 | Labour for cutting D.I. pipe with steel saw. 600 mm diameter D.I. pipe | BI01010001010000000000000515BI0100001131 | 5 | No |
21 | 1.02 | Labour for cutting D.I. pipe with steel saw. 450 mm diameter D.I. pipe | BI01010001010000000000000515BI0100001132 | 20 | No |
22 | 1.021 | Labour for cutting D.I. pipe with steel saw. 400 mm diameter D.I. pipe | BI01010001010000000000000515BI0100001133 | 10 | Each Cut |
23 | 1.022 | Labour for cutting D.I. pipe with steel saw. 350 mm diameter D.I pipe | BI01010001010000000000000515BI0100001134 | 20 | Each Cut |
24 | 1.023 | Labour for cutting D.I. pipe with steel saw. 300 mm diameter D.I. pipe | BI01010001010000000000000515BI0100001135 | 30 | Each Cut |
25 | 1.024 | Labour for cutting D.I. pipe with steel saw.<br>250 mm diameter D.I. pipe | BI01010001010000000000000515BI0100001136 | 50 | Each Cut |
26 | 1.025 | Labour for cutting D.I. pipe with steel saw. 200 mm diameter D.I. pipe | BI01010001010000000000000515BI0100001137 | 10 | Each Cut |
27 | 1.026 | Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes | BI01010001010000000000000515BI0100001138 | 51 | joint |
28 | 1.027 | Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:400 mm dia pipes | BI01010001010000000000000515BI0100001139 | 39 | joint |
29 | 1.028 | Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:450 mm dia pipes | BI01010001010000000000000515BI0100001140 | 147 | joint |
30 | 1.029 | Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:600 mm dia pipes | BI01010001010000000000000515BI0100001141 | 20 | joint |
31 | 1.03 | Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:250 mm dia pipes | BI01010001010000000000000515BI0100001142 | 504 | joint |
32 | 1.031 | Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:300 mm dia pipe | BI01010001010000000000000515BI0100001143 | 338 | joint |
33 | 1.032 | Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:350 mm dia pipes | BI01010001010000000000000515BI0100001144 | 201 | joint |
34 | 1.033 | Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe | BI01010001010000000000000515BI0100001145 | 9 | Nos |
35 | 1.034 | Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:250 mm diameter pipe | BI01010001010000000000000515BI0100001146 | 9 | Nos |
36 | 1.035 | Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:300 mm diameter pipe | BI01010001010000000000000515BI0100001147 | 9 | Nos |
37 | 1.036 | Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:350 mm diameter pipe | BI01010001010000000000000515BI0100001148 | 9 | Nos |
38 | 1.037 | Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:400 mm diameter pipe | BI01010001010000000000000515BI0100001149 | 9 | Nos |
39 | 1.038 | Testing 200mm DI/CI pipeline with potable water to the required test pressure 200 mm dia Observed Data derived from item no.1020 of PHED DATA | BI01010001010000000000000515BI0100001150 | 266 | metre |
40 | 1.039 | Testing 250mm DI/CI pipeline with potable water to the required test pressure . 250 mm dia Observed Data derived from item no.1022 of PHED DATA | BI01010001010000000000000515BI0100001151 | 2518 | metre |
41 | 1.04 | Testing 300mm DI/CI pipeline with potable water to the required test pressure. 300 mm dia Observed Data derived from item no.1023 of PHED DATA | BI01010001010000000000000515BI0100001152 | 1688 | metre |
42 | 1.041 | Testing 350mm DI/CI pipeline with potable water to the required test pressure. 350 mm dia Observed Data derived from item no.1024 of PHED DATA | BI01010001010000000000000515BI0100001153 | 1002 | metre |
43 | 1.042 | Testing 400mm DI/CI pipeline with potable water to the required test pressure.400 mm dia Observed Data derived from item no.1026 of PHED DATA | BI01010001010000000000000515BI0100001154 | 197 | metre |
44 | 1.043 | Testing 450mm DI/CI pipeline with potable water to the required test pressure. 450 mm dia Observed Data derived from item no.1027 of PHED DATA | BI01010001010000000000000515BI0100001155 | 733 | metre |
45 | 1.044 | Testing 600mm DI/CI pipeline with potable water to the required test pressure. 600 mm dia Observed Data derived from item no.1029 of PHED DATA | BI01010001010000000000000515BI0100001156 | 100 | metre |
46 | 1.045 | "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :250 mm diameter. Class I"Data derived from item no.18.31.5.1 of DAR | BI01010001010000000000000515BI0100001157 | 4 | Nos |
47 | 1.046 | "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :300 mm diameter. Class I"Data derived from item no.18.31.6.1 of DAR | BI01010001010000000000000515BI0100001158 | 3 | Nos |
48 | 1.047 | "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :350 mm diameter. Class I"Observed Data derived from item no.18.31.of DAR | BI01010001010000000000000515BI0100001159 | 2 | Nos |
49 | 1.048 | Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 450 mm diameter. Class I"Observed Data derived from item no.18.31.of DAR | BI01010001010000000000000515BI0100001160 | 2 | Nos |
50 | 1.049 | "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :600 mm diameter. Class I"Observed Data derived from item no.18.31.of DAR | BI01010001010000000000000515BI0100001161 | 1 | Nos |
51 | 1.05 | Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately):50 mm Double acting Air Valve Data derived from item no.18.59.1 of DAR | BI01010001010000000000000515BI0100001162 | 5 | Nos |
52 | 1.051 | Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 80 mm Double acting Air Valve Data derived from item no.18.59.2 of DAR | BI01010001010000000000000515BI0100001163 | 5 | Nos |
53 | 1.052 | Taking connection from existing line of size 50mm to 110mm, using PVC specials including all earthwork excavation, re-filling etc, including cost of specials | BI01010001010000000000000515BI0100001164 | 50 | No |
54 | 1.053 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | BI01010001010000000000000515BI0100001165 | 203.743 | cum |
55 | 1.054 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001166 | 44.048 | cum |
56 | 1.055 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size | BI01010001010000000000000515BI0100001167 | 77.165 | cum |
57 | 1.056 | Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | BI01010001010000000000000515BI0100001168 | 493.68 | sqm |
58 | 1.057 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | BI01010001010000000000000515BI0100001169 | 211.161 | sqm |
59 | 1.058 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001170 | 6173.2 | kilogram |
60 | 1.059 | 12 mm cement plaster of mix: | BI01010001010000000000000515BI0100001171 | 267.3 | sqm |
61 | 1.06 | Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. | BI01010001010000000000000515BI0100001172 | 8639 | metre |
62 | 1.061 | Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road | BI01010001010000000000000515BI0100001173 | 4319.5 | sqm |
63 | 1.062 | Refilling the trenches with a wet mix of close graded granular materials (Stone aggregate - 25mm nominal size - 17.5%, Stone aggregate - 10mm nominal size - 17.5%, Crushed Stone - 2.36mm to 12.5mm - 25%, Stone chippings / screenings - 4.75mm nominal size - 20%, Stone chippings / screenings - 150 micron nominal size - 20%), mixing properly after adding sufficient quantity of water, refilling in layers not exceeding 150mm, compacting properly at Optimum Moisture Content with Surface Plate Vibrator and disposing the excavated material etc. complete, including traffic control, providing caution boards and as per direction of Engineer-in-charge for road restoration works in pipeline leak sites. | BI01010001010000000000000515BI0100001174 | 391.5 | cum |
64 | 1.063 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001175 | 37.5 | cum |
65 | 2 | Appendix B - Cost of materials | BI01010001010000000000000515BI0100001176 | ||
66 | 2.001 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 250mm. | BI01010001010000000000000515BI0100001177 | 4 | No |
67 | 2.002 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 300mm. | BI01010001010000000000000515BI0100001178 | 3 | No |
68 | 2.003 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 350mm. | BI01010001010000000000000515BI0100001179 | 2 | No |
69 | 2.004 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 450mm. | BI01010001010000000000000515BI0100001180 | 2 | No |
70 | 2.005 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 600mm. | BI01010001010000000000000515BI0100001181 | 1 | No |
71 | 2.006 | Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 50mm. | BI01010001010000000000000515BI0100001182 | 5 | No |
72 | 2.007 | Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 80mm. | BI01010001010000000000000515BI0100001183 | 5 | No |
73 | 2.008 | Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia. | BI01010001010000000000000515BI0100001184 | 254 | metre |
74 | 2.009 | Supply of DI K9 Pipe Conforming to IS 8329/2000, 250mm Dia. | BI01010001010000000000000515BI0100001185 | 2528 | metre |
75 | 2.01 | Supply of DI K9 Pipe Conforming to IS 8329/2000, 300mm Dia. | BI01010001010000000000000515BI0100001186 | 1689 | metre |
76 | 2.011 | Supply of DI K9 Pipe Conforming to IS 8329/2000, 350mm Dia. | BI01010001010000000000000515BI0100001187 | 997 | metre |
77 | 2.012 | Supply of DI K9 Pipe Conforming to IS 8329/2000, 400mm Dia. | BI01010001010000000000000515BI0100001188 | 184 | metre |
78 | 2.013 | Supply of DI K9 Pipe Conforming to IS 8329/2000, 450mm Dia. | BI01010001010000000000000515BI0100001189 | 741 | metre |
79 | 2.014 | Supply of DI K9 Pipe Conforming to IS 8329/2000, 600mm Dia. | BI01010001010000000000000515BI0100001190 | 102 | metre |
80 | 2.015 | Supply & delivery of 400mm DI K9 Double Flanged pipe | BI01010001010000000000000515BI0100001191 | 15 | metre |
81 | 2.016 | Supply & delivery of 350mm DI K9 Double Flanged pipe | BI01010001010000000000000515BI0100001192 | 15 | metre |
82 | 2.017 | Supply & delivery of 200mm DI K9 Double Flanged pipe | BI01010001010000000000000515BI0100001193 | 15 | metre |
83 | 2.018 | Supply & delivery of 250mm DI K9 Double Flanged pipe | BI01010001010000000000000515BI0100001194 | 15 | metre |
84 | 2.019 | Supply & delivery of 300mm DI K9 Double Flanged pipe | BI01010001010000000000000515BI0100001195 | 15 | metre |
85 | 2.02 | Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 : | BI01010001010000000000000515BI0100001196 | 48.09 | quintal |
86 | 2.021 | Supply of PVC Pipe, 6kg/cm2, 50mm Dia. | BI01010001010000000000000515BI0100001197 | 3000 | metre |
87 | 2.022 | Supply of PVC Pipe, 6kg/cm2, 90mm Dia. | BI01010001010000000000000515BI0100001198 | 9000 | metre |
88 | 2.023 | Cost of PVC Specials @ 3% | BI01010001010000000000000515BI0100001199 | 1 | L.S |
89 | 3 | Appendix D - Providing FHTCs ongoing Scheme | BI01010001010000000000000515BI0100001203 | ||
90 | 3.001 | Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. | BI01010001010000000000000515BI0100001204 | 2700 | Nos |
91 | 3.002 | Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains from 140mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. | BI01010001010000000000000515BI0100001205 | 250 | Nos |
92 | 3.003 | Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains from 150mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. | BI01010001010000000000000515BI0100001206 | 100 | Nos |
93 | 3.004 | Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains up to 125 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. | BI01010001010000000000000515BI0100001207 | 100 | Nos |
94 | 3.005 | Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. | BI01010001010000000000000515BI0100001208 | 3150 | Nos |
95 | 3.006 | Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers. | BI01010001010000000000000515BI0100001209 | 3150 | Nos |
96 | 3.007 | Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers. | BI01010001010000000000000515BI0100001210 | 12000 | metre |
97 | 3.008 | Geo Tagging | BI01010001010000000000000515BI0100001211 | 3150 | No |
98 | 3.009 | Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. | BI01010001010000000000000515BI0100001212 | 6000 | metre |
99 | 3.01 | Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road | BI01010001010000000000000515BI0100001213 | 1800 | sqm |
100 | 3.011 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) | BI01010001010000000000000515BI0100001214 | 270 | cum |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail