Jjm Thrissur District Vadanappilly Gramapanchayath Providing Fhtc To Rural House Holds And Allied Works . , Vadanappilly-Kerala

Kerala Water Authority-KWA has published Jjm Thrissur District Vadanappilly Gramapanchayath Providing Fhtc To Rural House Holds And Allied Works . . Submission Date for this Tender is 06-11-2020. Pipe Laying Tenders in Vadanappilly Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

25848785
Jjm Thrissur District Vadanappilly Gramapanchayath Providing Fhtc To Rural House Holds And Allied Works .
Open Tender
Indian
Kerala
Vadanappilly
06-11-2020

Tender Details

Jjm Thrissur District Vadanappilly Gramapanchayath Providing Fhtc To Rural House Holds And Allied Works .

Key Value

Document Fees
INR 11200 /-
EMD
INR 200000.0 /-
Tender Value
INR 6.21 Crore /-

BOQ Items

Work Name: JJM–Thrissur district– Vadanappilly Gramapanchayath -Providing FHTC to Rural house holds and allied works.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Appendix A - Distribution strengthing (Working Charge) BI01010001010000000000000515BI0100001112
2 1.001 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR) BI01010001010000000000000515BI0100001113 13646 cum
3 1.002 Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009) BI01010001010000000000000515BI0100001114 6500 metre
4 1.003 Open timbering in trenches including strutting and shoring complete ( measurements to be taken of the face area timbered ):Depth not exceeding 1.5 m BI01010001010000000000000515BI0100001115 3172.5 sqm
5 1.004 Bailing out water with 5 HP engine and pumpset including conveyance to the site, errection, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc. complete.NEW DATA (Prepared based on PHED SDB - Item No.1070 BI01010001010000000000000515BI0100001116 500 Kwh
6 1.005 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 600 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.24 in DAR BI01010001010000000000000515BI0100001117 100 metre
7 1.006 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 450 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.22 in DAR BI01010001010000000000000515BI0100001118 733 metre
8 1.007 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 400 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.21 in DAR BI01010001010000000000000515BI0100001119 182 metre
9 1.008 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials :350 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.20 in DAR BI01010001010000000000000515BI0100001120 987 metre
10 1.009 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 300 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.19 in DAR BI01010001010000000000000515BI0100001121 1673 metre
11 1.01 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 250 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.18 in DAR BI01010001010000000000000515BI0100001122 2503 metre
12 1.011 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials :200 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.17 in DAR BI01010001010000000000000515BI0100001123 251 metre
13 1.012 Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 90 mm nominal outer dia pipes." BI01010001010000000000000515BI0100001124 9000 metre
14 1.013 Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes. BI01010001010000000000000515BI0100001125 3000 metre
15 1.014 Conveying and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) excluding cost of pipe and specials: 400 mm dia C.I.Double Fanged Pipe Data derived from 18.71.7 in DAR BI01010001010000000000000515BI0100001126 15 metre
16 1.015 Conveying and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) excluding cost of pipe and specials: 350 mm dia C.I.Double Fanged Pipe Data derived from 18.71.6 in DAR BI01010001010000000000000515BI0100001127 15 metre
17 1.016 Conveying and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) excluding cost of pipe and specials: 300 mm dia C.I.Double Fanged Pipe Data derived from 18.71.5 in DAR BI01010001010000000000000515BI0100001128 15 metre
18 1.017 Conveying and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) excluding cost of pipe and specials: 250 mm dia C.I.Double Fanged Pipe Data derived from 18.71.4 in DAR BI01010001010000000000000515BI0100001129 15 metre
19 1.018 Conveying and laying Double Flanged (screwed / welded) Centrifugally (Spun) Cast Iron, Class B (IS : 1536) excluding cost of pipe and specials: 200 mm dia C.I.Double Fanged Pipe Data derived from 18.71.3 in DARData for 5 m BI01010001010000000000000515BI0100001130 15 metre
20 1.019 Labour for cutting D.I. pipe with steel saw. 600 mm diameter D.I. pipe BI01010001010000000000000515BI0100001131 5 No
21 1.02 Labour for cutting D.I. pipe with steel saw. 450 mm diameter D.I. pipe BI01010001010000000000000515BI0100001132 20 No
22 1.021 Labour for cutting D.I. pipe with steel saw. 400 mm diameter D.I. pipe BI01010001010000000000000515BI0100001133 10 Each Cut
23 1.022 Labour for cutting D.I. pipe with steel saw. 350 mm diameter D.I pipe BI01010001010000000000000515BI0100001134 20 Each Cut
24 1.023 Labour for cutting D.I. pipe with steel saw. 300 mm diameter D.I. pipe BI01010001010000000000000515BI0100001135 30 Each Cut
25 1.024 Labour for cutting D.I. pipe with steel saw.<br>250 mm diameter D.I. pipe BI01010001010000000000000515BI0100001136 50 Each Cut
26 1.025 Labour for cutting D.I. pipe with steel saw. 200 mm diameter D.I. pipe BI01010001010000000000000515BI0100001137 10 Each Cut
27 1.026 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes BI01010001010000000000000515BI0100001138 51 joint
28 1.027 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:400 mm dia pipes BI01010001010000000000000515BI0100001139 39 joint
29 1.028 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:450 mm dia pipes BI01010001010000000000000515BI0100001140 147 joint
30 1.029 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:600 mm dia pipes BI01010001010000000000000515BI0100001141 20 joint
31 1.03 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:250 mm dia pipes BI01010001010000000000000515BI0100001142 504 joint
32 1.031 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:300 mm dia pipe BI01010001010000000000000515BI0100001143 338 joint
33 1.032 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:350 mm dia pipes BI01010001010000000000000515BI0100001144 201 joint
34 1.033 Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe BI01010001010000000000000515BI0100001145 9 Nos
35 1.034 Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:250 mm diameter pipe BI01010001010000000000000515BI0100001146 9 Nos
36 1.035 Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:300 mm diameter pipe BI01010001010000000000000515BI0100001147 9 Nos
37 1.036 Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:350 mm diameter pipe BI01010001010000000000000515BI0100001148 9 Nos
38 1.037 Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:400 mm diameter pipe BI01010001010000000000000515BI0100001149 9 Nos
39 1.038 Testing 200mm DI/CI pipeline with potable water to the required test pressure 200 mm dia Observed Data derived from item no.1020 of PHED DATA BI01010001010000000000000515BI0100001150 266 metre
40 1.039 Testing 250mm DI/CI pipeline with potable water to the required test pressure . 250 mm dia Observed Data derived from item no.1022 of PHED DATA BI01010001010000000000000515BI0100001151 2518 metre
41 1.04 Testing 300mm DI/CI pipeline with potable water to the required test pressure. 300 mm dia Observed Data derived from item no.1023 of PHED DATA BI01010001010000000000000515BI0100001152 1688 metre
42 1.041 Testing 350mm DI/CI pipeline with potable water to the required test pressure. 350 mm dia Observed Data derived from item no.1024 of PHED DATA BI01010001010000000000000515BI0100001153 1002 metre
43 1.042 Testing 400mm DI/CI pipeline with potable water to the required test pressure.400 mm dia Observed Data derived from item no.1026 of PHED DATA BI01010001010000000000000515BI0100001154 197 metre
44 1.043 Testing 450mm DI/CI pipeline with potable water to the required test pressure. 450 mm dia Observed Data derived from item no.1027 of PHED DATA BI01010001010000000000000515BI0100001155 733 metre
45 1.044 Testing 600mm DI/CI pipeline with potable water to the required test pressure. 600 mm dia Observed Data derived from item no.1029 of PHED DATA BI01010001010000000000000515BI0100001156 100 metre
46 1.045 "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :250 mm diameter. Class I"Data derived from item no.18.31.5.1 of DAR BI01010001010000000000000515BI0100001157 4 Nos
47 1.046 "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :300 mm diameter. Class I"Data derived from item no.18.31.6.1 of DAR BI01010001010000000000000515BI0100001158 3 Nos
48 1.047 "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :350 mm diameter. Class I"Observed Data derived from item no.18.31.of DAR BI01010001010000000000000515BI0100001159 2 Nos
49 1.048 Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 450 mm diameter. Class I"Observed Data derived from item no.18.31.of DAR BI01010001010000000000000515BI0100001160 2 Nos
50 1.049 "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :600 mm diameter. Class I"Observed Data derived from item no.18.31.of DAR BI01010001010000000000000515BI0100001161 1 Nos
51 1.05 Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately):50 mm Double acting Air Valve Data derived from item no.18.59.1 of DAR BI01010001010000000000000515BI0100001162 5 Nos
52 1.051 Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 80 mm Double acting Air Valve Data derived from item no.18.59.2 of DAR BI01010001010000000000000515BI0100001163 5 Nos
53 1.052 Taking connection from existing line of size 50mm to 110mm, using PVC specials including all earthwork excavation, re-filling etc, including cost of specials BI01010001010000000000000515BI0100001164 50 No
54 1.053 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil BI01010001010000000000000515BI0100001165 203.743 cum
55 1.054 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001166 44.048 cum
56 1.055 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size BI01010001010000000000000515BI0100001167 77.165 cum
57 1.056 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. BI01010001010000000000000515BI0100001168 493.68 sqm
58 1.057 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete BI01010001010000000000000515BI0100001169 211.161 sqm
59 1.058 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more BI01010001010000000000000515BI0100001170 6173.2 kilogram
60 1.059 12 mm cement plaster of mix: BI01010001010000000000000515BI0100001171 267.3 sqm
61 1.06 Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. BI01010001010000000000000515BI0100001172 8639 metre
62 1.061 Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road BI01010001010000000000000515BI0100001173 4319.5 sqm
63 1.062 Refilling the trenches with a wet mix of close graded granular materials (Stone aggregate - 25mm nominal size - 17.5%, Stone aggregate - 10mm nominal size - 17.5%, Crushed Stone - 2.36mm to 12.5mm - 25%, Stone chippings / screenings - 4.75mm nominal size - 20%, Stone chippings / screenings - 150 micron nominal size - 20%), mixing properly after adding sufficient quantity of water, refilling in layers not exceeding 150mm, compacting properly at Optimum Moisture Content with Surface Plate Vibrator and disposing the excavated material etc. complete, including traffic control, providing caution boards and as per direction of Engineer-in-charge for road restoration works in pipeline leak sites. BI01010001010000000000000515BI0100001174 391.5 cum
64 1.063 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001175 37.5 cum
65 2 Appendix B - Cost of materials BI01010001010000000000000515BI0100001176
66 2.001 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 250mm. BI01010001010000000000000515BI0100001177 4 No
67 2.002 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 300mm. BI01010001010000000000000515BI0100001178 3 No
68 2.003 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 350mm. BI01010001010000000000000515BI0100001179 2 No
69 2.004 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 450mm. BI01010001010000000000000515BI0100001180 2 No
70 2.005 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 600mm. BI01010001010000000000000515BI0100001181 1 No
71 2.006 Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 50mm. BI01010001010000000000000515BI0100001182 5 No
72 2.007 Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 80mm. BI01010001010000000000000515BI0100001183 5 No
73 2.008 Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia. BI01010001010000000000000515BI0100001184 254 metre
74 2.009 Supply of DI K9 Pipe Conforming to IS 8329/2000, 250mm Dia. BI01010001010000000000000515BI0100001185 2528 metre
75 2.01 Supply of DI K9 Pipe Conforming to IS 8329/2000, 300mm Dia. BI01010001010000000000000515BI0100001186 1689 metre
76 2.011 Supply of DI K9 Pipe Conforming to IS 8329/2000, 350mm Dia. BI01010001010000000000000515BI0100001187 997 metre
77 2.012 Supply of DI K9 Pipe Conforming to IS 8329/2000, 400mm Dia. BI01010001010000000000000515BI0100001188 184 metre
78 2.013 Supply of DI K9 Pipe Conforming to IS 8329/2000, 450mm Dia. BI01010001010000000000000515BI0100001189 741 metre
79 2.014 Supply of DI K9 Pipe Conforming to IS 8329/2000, 600mm Dia. BI01010001010000000000000515BI0100001190 102 metre
80 2.015 Supply & delivery of 400mm DI K9 Double Flanged pipe BI01010001010000000000000515BI0100001191 15 metre
81 2.016 Supply & delivery of 350mm DI K9 Double Flanged pipe BI01010001010000000000000515BI0100001192 15 metre
82 2.017 Supply & delivery of 200mm DI K9 Double Flanged pipe BI01010001010000000000000515BI0100001193 15 metre
83 2.018 Supply & delivery of 250mm DI K9 Double Flanged pipe BI01010001010000000000000515BI0100001194 15 metre
84 2.019 Supply & delivery of 300mm DI K9 Double Flanged pipe BI01010001010000000000000515BI0100001195 15 metre
85 2.02 Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 : BI01010001010000000000000515BI0100001196 48.09 quintal
86 2.021 Supply of PVC Pipe, 6kg/cm2, 50mm Dia. BI01010001010000000000000515BI0100001197 3000 metre
87 2.022 Supply of PVC Pipe, 6kg/cm2, 90mm Dia. BI01010001010000000000000515BI0100001198 9000 metre
88 2.023 Cost of PVC Specials @ 3% BI01010001010000000000000515BI0100001199 1 L.S
89 3 Appendix D - Providing FHTCs ongoing Scheme BI01010001010000000000000515BI0100001203
90 3.001 Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. BI01010001010000000000000515BI0100001204 2700 Nos
91 3.002 Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains from 140mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. BI01010001010000000000000515BI0100001205 250 Nos
92 3.003 Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains from 150mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. BI01010001010000000000000515BI0100001206 100 Nos
93 3.004 Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains up to 125 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. BI01010001010000000000000515BI0100001207 100 Nos
94 3.005 Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. BI01010001010000000000000515BI0100001208 3150 Nos
95 3.006 Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers. BI01010001010000000000000515BI0100001209 3150 Nos
96 3.007 Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers. BI01010001010000000000000515BI0100001210 12000 metre
97 3.008 Geo Tagging BI01010001010000000000000515BI0100001211 3150 No
98 3.009 Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. BI01010001010000000000000515BI0100001212 6000 metre
99 3.01 Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road BI01010001010000000000000515BI0100001213 1800 sqm
100 3.011 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) BI01010001010000000000000515BI0100001214 270 cum
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy